{"lab":{"_id":"69ad52a3de79e566650fb2f2","accr_number":"AB 582","country":"PL","accr_body":"PCA","address":"W WAŁBRZYCHU, ul. Armii Krajowej 35 C, 58-302 Wałbrzych","categories":["water","environment","microbiology"],"city":"Wałbrzych","imported_at":"2026-03-08T10:42:43.265Z","methods_count":42,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_582.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w wałbrzychu, ul. armii krajowej 35 c, 58-302 wałbrzych water automotive other microbiology pharma electronics environment materials construction metrology","status":"active","updated_at":"2026-03-08T14:51:28.093Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:28.093Z","location":{"type":"Point","coordinates":[16.2843,50.7714]},"email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/psse-walbrzych/dane-kontaktowe","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze","en":"Chemical tests and sampling – working environment (harmful factors – air)"},{"codes":"C/35","pl":"Badania chemiczne – pomieszczenia (warunki środowiskowe) – powietrze","en":"Chemical tests – facilities (environmental conditions) – air"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, drgania, hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – lighting, vibration, noise)"},{"codes":"K/3; K/28; K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"}],"issue":{"no":"29","date":"23.01.2026"},"parse_date":"2026-07-20T07:09:43.793Z","parse_source":"script-pdfplumber","map_coord":[50.785353,16.286579],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":27,"environment":14,"microbiology":7,"construction":2,"materials":1},"category_scores":{"water":14.29,"environment":3.84,"microbiology":0.96,"construction":0.08,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9b7f1c10c8ce825d22f","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d230","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów","methodology_en":"Total microorganism count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total microorganism count Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","technique_zh":"平板法，倾注平板","methodology_zh":"微生物总数"},{"_id":"6a5dc9b7f1c10c8ce825d231","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli, Escherichia coli","methodology_en":"Coliform bacteria count, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["microbiology","water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","search_zh":"水、生活饮用水 大肠菌群数、大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"大肠菌群数、大肠埃希氏菌数"},{"_id":"6a5dc9b7f1c10c8ce825d232","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba enterokoków","methodology_en":"Enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"肠球菌计数","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d233","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli","methodology_en":"Most probable number of coliform bacteria, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","search_zh":"水、生活饮用水 大肠菌群、大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","methodology_zh":"大肠菌群、大肠埃希氏菌最可能数"},{"_id":"6a5dc9b7f1c10c8ce825d234","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)","methodology_en":"Clostridium perfringens count (including spores)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9b7f1c10c8ce825d235","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka A), 7 (pożywka C - GVPC) Matryca B Procedura 7, podłoże GVPC"}],"parameters_en":[{"name":"Matrix A Procedure 5 (medium A), 7 (medium C - GVPC) Matrix B Procedure 7, GVPC medium"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka A), 7 (pożywka C - GVPC) Matryca B Procedura 7, podłoże GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/ Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka A), 7 (pożywka C - GVPC) Matryca B Procedura 7, podłoże GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka A), 7 (pozywka C - GVPC) Matryca B Procedura 7, podloze GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","categories":["microbiology","water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C - GVPC) Matrix B Procedure 7, GVPC medium PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","search_zh":"水、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9b7f1c10c8ce825d236","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba gronkowców koagulazo-dodatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"Metodyka NIZP PZH ZHK:2007","norm_bases":["Metodyka NIZP PZH ZHK:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej Metodyka NIZP PZH ZHK:2007 Woda na plywalniach Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej Metodyka NIZP PZH ZHK:2007","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method Metodyka NIZP PZH ZHK:2007","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 Metodyka NIZP PZH ZHK:2007","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a5dc9b7f1c10c8ce825d237","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli","methodology_en":"Most probable number of coliform bacteria, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda na plywalniach Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Most probable number of coliform bacteria, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","search_zh":"游泳池水 大肠菌群、大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"游泳池水","methodology_zh":"大肠菌群、大肠埃希氏菌最可能数"},{"_id":"6a5dc9b7f1c10c8ce825d238","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Najbardziej prawdopodobna liczba, Pseudomonas aeruginosa","methodology_en":"Most probable number, Pseudomonas aeruginosa","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Pseudomonas aeruginosa\nMetoda NPL","reference":"PN-EN ISO 16266-2:2022-04","norm_bases":["PN-EN ISO 16266-2:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Najbardziej prawdopodobna liczba, Pseudomonas aeruginosa\nMetoda NPL PN-EN ISO 16266-2:2022-04 Woda na plywalniach Najbardziej prawdopodobna liczba, Pseudomonas aeruginosa\nMetoda NPL PN-EN ISO 16266-2:2022-04","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Most probable number, Pseudomonas aeruginosa MPN method PN-EN ISO 16266-2:2022-04","search_zh":"游泳池水 最可能数，铜绿假单胞菌 最可能数法（MPN） PN-EN ISO 16266-2:2022-04","technique_zh":"最可能数法（MPN）","test_object_zh":"游泳池水","methodology_zh":"最可能数，铜绿假单胞菌"},{"_id":"6a5dc9b7f1c10c8ce825d239","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów","methodology_en":"Total microorganism count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total microorganism count Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"游泳池水 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"游泳池水","technique_zh":"平板法，倾注平板","methodology_zh":"微生物总数"},{"_id":"6a5dc9b7f1c10c8ce825d23a","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["water","microbiology"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b7f1c10c8ce825d23b","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka A), 7 (pożywka C - GVPC) Matryca B Procedura 7, podłoże GVPC"}],"parameters_en":[{"name":"Matrix A Procedure 5 (medium A), 7 (medium C - GVPC) Matrix B Procedure 7, GVPC medium"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka A), 7 (pożywka C - GVPC) Matryca B Procedura 7, podłoże GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/ Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka A), 7 (pożywka C - GVPC) Matryca B Procedura 7, podłoże GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka A), 7 (pozywka C - GVPC) Matryca B Procedura 7, podloze GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","categories":["microbiology","water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C - GVPC) Matrix B Procedure 7, GVPC medium PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","search_zh":"游泳池水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9b7f1c10c8ce825d23c","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Kał, wymaz z odbytu, Szczepy drobnoustrojów","test_object_en":"Faeces, rectal swab, Microbial strains","methodology":"Obecność i identyfikacja pałeczek, Salmonella, Shigella","methodology_en":"Presence and identification of rods, Salmonella, Shigella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek, Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-LM/L-09 wersja 07 z dnia 08.11.2021 r.","norm_bases":["PB-LM/L-09 wersja 07 z dnia 08.11.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, wymaz z odbytu, Szczepy drobnoustrojów Obecność i identyfikacja pałeczek, Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LM/L-09 wersja 07 z dnia 08.11.2021 r. Kal, wymaz z odbytu, Szczepy drobnoustrojow Obecnosc i identyfikacja paleczek, Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LM/L-09 wersja 07 z dnia 08.11.2021 r.","categories":["microbiology"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces, rectal swab, Microbial strains Presence and identification of rods, Salmonella, Shigella Culture method with biochemical and serological confirmation PB-LM/L-09 wersja 07 z dnia 08.11.2021 r.","methodology_zh":"沙门氏菌与志贺氏菌检出与鉴定","search_zh":"沙门氏菌与志贺氏菌检出与鉴定 培养法结合生化与血清学确认 PB-LM/L-09 wersja 07 z dnia 08.11.2021 r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a5dc9b7f1c10c8ce825d23d","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,060 - 0,80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,060 - 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,060 - 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,060 - 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,060 - 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,060 - 0,80) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d23e","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,020 - 0,60) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 - 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 0,60) mg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d23f","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,030 - 0,60) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,030 - 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,030 - 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,030 - 0,60) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,030 - 0,60) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,030 - 0,60) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d240","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość (sumaryczne stężenie wapnia i magnezu)","methodology_en":"Hardness (total concentration of calcium and magnesium)","parameters":[{"name":"Zakres","range":"(20 - 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(20 - 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość (sumaryczne stężenie wapnia i magnezu)\nZakres (20 - 500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość (sumaryczne stężenie wapnia i magnezu)\nZakres (20 - 500) mg/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc (sumaryczne stezenie wapnia i magnezu)\nZakres (20 - 500) mg/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Hardness (total concentration of calcium and magnesium) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(20 - 500) mg/l"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d241","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 - 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 300) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d242","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 - 2500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 - 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 - 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 - 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d243","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonu","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,10 - 0,80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonu\nZakres (0,10 - 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonu\nZakres (0,10 - 0,80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonu\nZakres (0,10 - 0,80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","parameters_zh":[{"name":"范围","range":"(0,10 - 0,80) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a5dc9b7f1c10c8ce825d244","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,20 - 1,6) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 - 1,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,20 - 1,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-75/C-04588/01","norm_bases":["PN-75/C-04588/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,20 - 1,6) mg/l\nMetoda spektrofotometryczna PN-75/C-04588/01 Woda, woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,20 - 1,6) mg/l\nMetoda spektrofotometryczna PN-75/C-04588/01","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Fluoride concentration Spectrophotometric method Range PN-75/C-04588/01","parameters_zh":[{"name":"范围","range":"(0,20 - 1,6) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 分光光度法 范围 PN-75/C-04588/01","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9b7f1c10c8ce825d245","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 - 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 - 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 - 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 pkt. 7","norm_bases":["PN-EN ISO 7887:2012 pkt. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 - 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 pkt. 7 Woda, woda do spozycia przez ludzi Barwa\nZakres (5 - 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 pkt. 7","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012 pkt. 7","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 pkt. 7","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d246","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie boru","methodology_en":"Boron concentration","parameters":[{"name":"Zakres","range":"(0,20 – 1,2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 1,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie boru\nZakres (0,20 – 1,2) mg/l\nMetoda spektrofotometryczna","reference":"PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r.","norm_bases":["PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie boru\nZakres (0,20 – 1,2) mg/l\nMetoda spektrofotometryczna PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r. Woda, woda do spozycia przez ludzi Stezenie boru\nZakres (0,20 – 1,2) mg/l\nMetoda spektrofotometryczna PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r.","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Boron concentration Spectrophotometric method Range PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r.","parameters_zh":[{"name":"范围","range":"(0,20 – 1,2) mg/l"}],"search_zh":"水、生活饮用水 硼浓度 分光光度法 范围 PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"硼浓度"},{"_id":"6a5dc9b7f1c10c8ce825d247","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,50 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,50 - 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,50 - 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,50 - 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,50 - 50) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d248","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水（含游泳池水）、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d249","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 - 40) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 - 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 - 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Mętność\nZakres (0,10 - 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 40) NTU"}],"search_zh":"水（含游泳池水）、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d24a","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,50 - 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 - 10) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 10) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 - 10) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 - 10) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 - 10) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d24b","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe frakcja wdychalna frakcja respirabilna"},{"name":"substancje nieorganiczne frakcja respirabilna"},{"name":"metale i ich związki, w tym frakcja wdychalna frakcja respirabilna"}],"parameters_en":[{"name":"dust agents inhalable fraction respirable fraction"},{"name":"inorganic substances respirable fraction"},{"name":"metals and their compounds, including inhalable fraction respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nsubstancje nieorganiczne frakcja respirabilna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nsubstancje nieorganiczne frakcja respirabilna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe frakcja wdychalna frakcja respirabilna\nsubstancje nieorganiczne frakcja respirabilna\nmetale i ich zwiazki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction inorganic substances respirable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因子 可吸入性粉尘 呼吸性粉尘 无机物质 呼吸性粉尘 金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因子 可吸入性粉尘 呼吸性粉尘"},{"name":"无机物质 呼吸性粉尘"},{"name":"金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘"}]},{"_id":"6a5dc9b7f1c10c8ce825d24c","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"substancje nieorganiczne"}],"parameters_en":[{"name":"inorganic substances"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"technique_en":"Personal dosimetry method; Stationary method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method inorganic substances PN-Z-04008-7:2002+Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 无机物质 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质"}],"technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a5dc9b7f1c10c8ce825d24d","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9b7f1c10c8ce825d24e","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych – frakcja wdychalna","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,20 – 20,5) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,20 – 20,5) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,20 – 20,5) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,20 – 20,5) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,20 – 20,5) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05+Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,20 – 20,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9b7f1c10c8ce825d24f","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych – frakcja respirabilna","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 4,6) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,10 – 4,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 4,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 4,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,10 – 4,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05+Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 4,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9b7f1c10c8ce825d250","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,3 – 234) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,3 – 234) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (2,3 – 234) mg/m3\nMetoda elektrochemiczna","reference":"PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","norm_bases":["PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres (2,3 – 234) mg/m3\nMetoda elektrochemiczna PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres (2,3 – 234) mg/m3\nMetoda elektrochemiczna PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","parameters_zh":[{"name":"范围","range":"(2,3 – 234) mg/m3"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9b7f1c10c8ce825d251","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","norm_bases":["PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r. Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure index (calculated) PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9b7f1c10c8ce825d252","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie ditlenku siarki","methodology_en":"Sulphur dioxide concentration","parameters":[{"name":"Zakres","range":"(0,13 – 8,5) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,13 – 8,5) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ditlenku siarki\nZakres (0,13 – 8,5) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04015.12:1996+Ap1:2001","norm_bases":["PN-Z-04015.12:1996+Ap1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie ditlenku siarki\nZakres (0,13 – 8,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04015.12:1996+Ap1:2001 Srodowisko pracy - powietrze Stezenie ditlenku siarki\nZakres (0,13 – 8,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04015.12:1996+Ap1:2001","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sulphur dioxide concentration Spectrophotometric method Range PN-Z-04015.12:1996+Ap1:2001","parameters_zh":[{"name":"范围","range":"(0,13 – 8,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 二氧化硫浓度 分光光度法 范围 PN-Z-04015.12:1996+Ap1:2001","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"二氧化硫浓度"},{"_id":"6a5dc9b7f1c10c8ce825d253","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań.","methodology_en":"RMS frequency-weighted vibration acceleration.","parameters":[{"name":"Zakres","range":"(0,03 - 100) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,03 - 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań.\nZakres (0,03 - 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań.\nZakres (0,03 - 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan.\nZakres (0,03 - 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - whole-body vibration RMS frequency-weighted vibration acceleration. Direct measurement method Range PN-EN 14253+A1:2011","parameters_zh":[{"name":"范围","range":"(0,03 - 100) m/s2"}],"search_zh":"工作场所环境 — 全身振动 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5dc9b7f1c10c8ce825d254","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5dc9b7f1c10c8ce825d255","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment - hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań.","methodology_en":"RMS frequency-weighted vibration acceleration.","parameters":[{"name":"Zakres","range":"(0,3 -100) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz). Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej, skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz) (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,3 -100) m/s2"},{"name":"Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,ahwz). Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,ahwz) (calculated)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań.\nZakres:\nZakres (0,3 -100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz). Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej, skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz) (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań.\nZakres:\nZakres (0,3 -100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz). Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej, skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz) (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan.\nZakres:\nZakres (0,3 -100) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy,ahwz). Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej, skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy,ahwz) (z obliczen)\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hand-arm vibration RMS frequency-weighted vibration acceleration. Direct measurement method Range Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,ahwz). Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","parameters_zh":[{"name":"范围","range":"(0,3 -100) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz). Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej, skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy,ahwz) (z obliczeń)"}],"search_zh":"工作场所环境 — 手传振动 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5dc9b7f1c10c8ce825d256","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A. Maksymalny poziom dźwięku A.","methodology_en":"A-weighted equivalent sound level. A-weighted maximum sound level.","parameters":[{"name":"Zakres","range":"(27 – 136) dB"},{"name":"Szczytowy poziom dźwięku C."},{"name":"Zakres","range":"(27 – 136) dB"},{"name":"Poziom ekspozycji na hałas odniesiony do:"},{"name":"8 godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(27 – 136) dB"},{"name":"C-weighted peak sound level."},{"name":"Range","range":"(27 – 136) dB"},{"name":"Noise exposure level referred to:"},{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A. Maksymalny poziom dźwięku A.\nZakres:\nZakres (27 – 136) dB\nSzczytowy poziom dźwięku C.\nZakres (27 – 136) dB\nPoziom ekspozycji na hałas odniesiony do:\n8 godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A. Maksymalny poziom dźwięku A.\nZakres:\nZakres (27 – 136) dB\nSzczytowy poziom dźwięku C.\nZakres (27 – 136) dB\nPoziom ekspozycji na hałas odniesiony do:\n8 godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A. Maksymalny poziom dzwieku A.\nZakres:\nZakres (27 – 136) dB\nSzczytowy poziom dzwieku C.\nZakres (27 – 136) dB\nPoziom ekspozycji na halas odniesiony do:\n8 godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen)\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 3 – punkt 11","categories":["environment"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise A-weighted equivalent sound level. A-weighted maximum sound level. Direct measurement method Range C-weighted peak sound level. Range Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11","parameters_zh":[{"name":"范围","range":"(27 – 136) dB"},{"name":"Szczytowy poziom dźwięku C."},{"name":"范围","range":"(27 – 136) dB"},{"name":"噪声暴露级，参照："},{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 直接测量法 范围 范围 噪声暴露级，参照： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9b7f1c10c8ce825d257","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(5 - 5000) lx"},{"name":"Równomierność oświetlenia (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(5 - 5000) lx"},{"name":"Illuminance uniformity (calculated)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres:\nZakres (5 - 5000) lx\nRównomierność oświetlenia (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r.","norm_bases":["P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres:\nZakres (5 - 5000) lx\nRównomierność oświetlenia (z obliczeń)\nMetoda pomiarowa bezpośrednia P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres:\nZakres (5 - 5000) lx\nRownomiernosc oswietlenia (z obliczen)\nMetoda pomiarowa bezposrednia P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r.","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range Illuminance uniformity (calculated) P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r.","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 - 5000) lx"},{"name":"照度均匀度（计算值）"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 照度均匀度（计算值） P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9b7f1c10c8ce825d258","lab_id":"69ad52a3de79e566650fb2f2","country":"PL","accr_number":"AB 582","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - powietrze","test_object_en":"Rooms in residential, collective residence and public buildings - air","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(3495 – 233000) μg/m3"}],"parameters_en":[{"name":"Range","range":"(3495 – 233000) μg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (3495 – 233000) μg/m3\nMetoda elektrochemiczna","reference":"PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r.","norm_bases":["PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - powietrze Stężenie tlenku węgla\nZakres (3495 – 233000) μg/m3\nMetoda elektrochemiczna PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r. Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - powietrze Stezenie tlenku wegla\nZakres (3495 – 233000) μg/m3\nMetoda elektrochemiczna PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r.","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public buildings - air Carbon monoxide concentration Electrochemical method Range PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r.","parameters_zh":[{"name":"范围","range":"(3495 – 233000) μg/m3"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 空气 一氧化碳浓度 电化学法 范围 PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r.","technique_zh":"电化学法","methodology_zh":"一氧化碳浓度","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 空气"}],"has_pdf":true}