🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 573 • Kwidzyn, Poland • 24 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 573 (Kwidzyn, Poland). Its accreditation scope covers 24 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water, Water intended for human consumption, Bathing water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 573
  • Methods in scope: 24
  • Types of test objects: 7
  • Techniques used: 10
  • City: Kwidzyn, Poland
Accreditation number
AB 573
Accreditation body
PCA
Address
W KWIDZYNIE, ul. Chopina 40
City
Kwidzyn, Poland

What this laboratory tests (7)

Analytical techniques used (10)

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
2 Water intended for human consumption Total viable count at 22 oC Plate method, pour plate PN-EN ISO 6222:2004
3 Water intended for human consumption, swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
4 Water intended for human consumption, bathing water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
5 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 zał. A
6 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
7 Swimming pool water Total viable count at 36 oC Plate method, pour plate PN-EN ISO 6222:2004
8 Bathing water Most probable number, Escherichia coli MPN method, miniaturized PN-EN ISO 9308-3:2002
9 Water, water intended for human consumption Turbidity
Range (0,10 – 30) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
10 Water, water intended for human consumption Electrical conductivity
Range 100 μS/cm - 100 mS/cm
Conductometric method PN-EN 27888:1999
11 Water, water intended for human consumption pH
Range 5,0 - 10,0
Potentiometric method PN-EN ISO 10523:2012
12 Water, water intended for human consumption Ammonium ion concentration
Range (0,08 - 2,0) mg/l
Spectrophotometric method PN-C-04576-4:1994
13 Water, water intended for human consumption Nitrate concentration
Range (0,08 - 1,0) mg/l
Spectrophotometric method PN-82/C-04576.08
14 Water, water intended for human consumption Nitrite concentration
Range (0,005 - 0,6) mg/l
Spectrophotometric method PN-EN 26777:1999
15 Water, water intended for human consumption Total iron concentration
Range (0,040 - 4,00) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016
16 Water, water intended for human consumption Ammonium ion concentration
Range (0,01 - 1,00) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
17 Water, water intended for human consumption Chloride concentration
Range (5,0 - 150) mg/l
Titrimetric method PN-ISO 9297:1994
18 Water, water intended for human consumption Hardness
Range (5 - 400) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
19 Water, water intended for human consumption Calcium concentration
Range (2 - 100) mg/l
Titrimetric method PN-ISO 6058:1999
20 Water, water intended for human consumption Magnesium concentration, Calculated PN-C-04554-4:1999 (Załącznik A)
21 Swimming pool water Free chlorine ˅
Range (0,03 – 3,0) mg/l
Colorimetric method PB_52_04 edycja 3 z 04.10.2024 r.
22 Swimming pool water Total chlorine ˅
Range (0,03 – 3,0) mg/l
Colorimetric method PB_52_04 edycja 3 z 04.10.2024 r.
23 Swimming pool water Combined chlorine, Calculated PB_52_04 edycja 3 z 04.10.2024 r.
24 Faeces, rectal swabs Presence and identification of rods of the genera Salmonella and Shigella Culture method with biochemical and serological confirmation PB_55_01 edycja 3 z 02.05.2024 r.

Reference standards (20)

PB_52_04 edycja 3 z 04.10.2024 r.
PB_55_01 edycja 3 z 02.05.2024 r.
PN-82/C-04576.08
PN-C-04554-4:1999 (Załącznik A)
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-3:2002
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-Z-11001-3:2000 zał. A