{"lab":{"_id":"69ad52a3de79e566650fb2e4","accr_number":"AB 573","country":"PL","accr_body":"PCA","address":"W KWIDZYNIE, ul. Chopina 40","categories":["water","microbiology"],"city":"Kwidzyn","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_573.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w kwidzynie, ul. chopina 40 other water automotive microbiology pharma electronics food","status":"active","updated_at":"2026-03-08T14:51:27.524Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:27.524Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20573,podmiot.html","fields_of_testing":[{"codes":"C/28, C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"K/3; K/28, K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań: wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"},{"codes":"N/28, N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"}],"issue":{"no":"21","date":"08.01.2025"},"parse_date":"2026-07-20T07:09:43.593Z","parse_source":"script-pdfplumber","map_coord":[53.731561,18.931995],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":23,"microbiology":4},"category_scores":{"water":19.59,"microbiology":0.59},"has_zh":true},"methods":[{"_id":"6a5dc9b7f1c10c8ce825d189","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d18a","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 oC","methodology_en":"Total viable count at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 oC\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total viable count at 22 oC Plate method, pour plate PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"生活饮用水 22 °C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"生活饮用水","technique_zh":"平板法，倾注平板"},{"_id":"6a5dc9b7f1c10c8ce825d18b","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda na pływalniach","test_object_en":"Water intended for human consumption, swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水、游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5dc9b7f1c10c8ce825d18c","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda w kąpieliskach","test_object_en":"Water intended for human consumption, bathing water","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, woda w kąpieliskach Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi, woda w kapieliskach Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, bathing water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法"},{"_id":"6a5dc9b7f1c10c8ce825d18d","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba gronkowców koagulazo-dodatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000 zał. A","norm_bases":["PN-Z-11001-3:2000 zał. A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 zał. A Woda na plywalniach Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 zal. A","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 zał. A","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 PN-Z-11001-3:2000 zał. A","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a5dc9b7f1c10c8ce825d18e","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b7f1c10c8ce825d18f","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w 36 oC","methodology_en":"Total viable count at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36 oC\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total viable count at 36 oC Plate method, pour plate PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"游泳池水 36 °C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"游泳池水","technique_zh":"平板法，倾注平板"},{"_id":"6a5dc9b7f1c10c8ce825d190","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda w kąpieliskach","test_object_en":"Bathing water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL, zminiaturyzowana","techniques":["Metoda NPL, zminiaturyzowana"],"technique_en":"MPN method, miniaturized","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL, zminiaturyzowana","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda w kąpieliskach Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL, zminiaturyzowana PN-EN ISO 9308-3:2002 Woda w kapieliskach Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL, zminiaturyzowana PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Bathing water Most probable number, Escherichia coli MPN method, miniaturized PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"浴场水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） PN-EN ISO 9308-3:2002","test_object_zh":"浴场水"},{"_id":"6a5dc9b7f1c10c8ce825d191","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 30) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 30) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 30) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,10 – 30) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 30) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 30) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d192","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"100 μS/cm - 100 mS/cm"}],"parameters_en":[{"name":"Range","range":"100 μS/cm - 100 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres 100 μS/cm - 100 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres 100 μS/cm - 100 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres 100 μS/cm - 100 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"100 μS/cm - 100 mS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d193","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"5,0 - 10,0"}],"parameters_en":[{"name":"Range","range":"5,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 5,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 5,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 5,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"5,0 - 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d194","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,08 - 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,08 - 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,08 - 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,08 - 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,08 - 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-C-04576-4:1994","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,08 - 2,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d195","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,08 - 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,08 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,08 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,08 - 1,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,08 - 1,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,08 - 1,0) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d196","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,005 - 0,6) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 - 0,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,005 - 0,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,005 - 0,6) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,005 - 0,6) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,005 - 0,6) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d197","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,040 - 4,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 - 4,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,040 - 4,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016","norm_bases":["PN-ISO 6332:2001+Ap1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,040 - 4,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,040 - 4,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,040 - 4,00) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d198","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,01 - 1,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,01 - 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,01 - 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,01 - 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,01 - 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,01 - 1,00) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d199","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 - 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 - 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 - 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 - 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 150) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d19a","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość","methodology_en":"Hardness","parameters":[{"name":"Zakres","range":"(5 - 400) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(5 - 400) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość\nZakres (5 - 400) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość\nZakres (5 - 400) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc\nZakres (5 - 400) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Hardness Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5 - 400) mg/l CaCO3"}],"search_zh":"水、生活饮用水 硬度 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"硬度"},{"_id":"6a5dc9b7f1c10c8ce825d19b","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 - 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 - 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 - 100) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9b7f1c10c8ce825d19c","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu, Z obliczeń","methodology_en":"Magnesium concentration, Calculated","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu, Z obliczeń","reference":"PN-C-04554-4:1999 (Załącznik A)","norm_bases":["PN-C-04554-4:1999 (Załącznik A)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu, Z obliczeń PN-C-04554-4:1999 (Załącznik A) Woda, woda do spozycia przez ludzi Stezenie magnezu, Z obliczen PN-C-04554-4:1999 (Zalacznik A)","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Magnesium concentration, Calculated PN-C-04554-4:1999 (Załącznik A)","search_zh":"水、生活饮用水 PN-C-04554-4:1999 (Załącznik A)","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b7f1c10c8ce825d19d","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Chlor wolny ˅","methodology_en":"Free chlorine ˅","parameters":[{"name":"Zakres","range":"(0,03 – 3,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 3,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Chlor wolny ˅\nZakres (0,03 – 3,0) mg/l\nMetoda kolorymetryczna","reference":"PB_52_04 edycja 3 z 04.10.2024 r.","norm_bases":["PB_52_04 edycja 3 z 04.10.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Chlor wolny ˅\nZakres (0,03 – 3,0) mg/l\nMetoda kolorymetryczna PB_52_04 edycja 3 z 04.10.2024 r. Woda na plywalniach Chlor wolny ˅\nZakres (0,03 – 3,0) mg/l\nMetoda kolorymetryczna PB_52_04 edycja 3 z 04.10.2024 r.","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Free chlorine ˅ Colorimetric method Range PB_52_04 edycja 3 z 04.10.2024 r.","parameters_zh":[{"name":"范围","range":"(0,03 – 3,0) mg/l"}],"search_zh":"游泳池水 比色法 范围 PB_52_04 edycja 3 z 04.10.2024 r.","technique_zh":"比色法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b7f1c10c8ce825d19e","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Chlor ogólny ˅","methodology_en":"Total chlorine ˅","parameters":[{"name":"Zakres","range":"(0,03 – 3,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 3,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Chlor ogólny ˅\nZakres (0,03 – 3,0) mg/l\nMetoda kolorymetryczna","reference":"PB_52_04 edycja 3 z 04.10.2024 r.","norm_bases":["PB_52_04 edycja 3 z 04.10.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Chlor ogólny ˅\nZakres (0,03 – 3,0) mg/l\nMetoda kolorymetryczna PB_52_04 edycja 3 z 04.10.2024 r. Woda na plywalniach Chlor ogolny ˅\nZakres (0,03 – 3,0) mg/l\nMetoda kolorymetryczna PB_52_04 edycja 3 z 04.10.2024 r.","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total chlorine ˅ Colorimetric method Range PB_52_04 edycja 3 z 04.10.2024 r.","parameters_zh":[{"name":"范围","range":"(0,03 – 3,0) mg/l"}],"search_zh":"游泳池水 比色法 范围 PB_52_04 edycja 3 z 04.10.2024 r.","technique_zh":"比色法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b7f1c10c8ce825d19f","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Chlor związany, Z obliczeń","methodology_en":"Combined chlorine, Calculated","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Chlor związany, Z obliczeń","reference":"PB_52_04 edycja 3 z 04.10.2024 r.","norm_bases":["PB_52_04 edycja 3 z 04.10.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Chlor związany, Z obliczeń PB_52_04 edycja 3 z 04.10.2024 r. Woda na plywalniach Chlor zwiazany, Z obliczen PB_52_04 edycja 3 z 04.10.2024 r.","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Combined chlorine, Calculated PB_52_04 edycja 3 z 04.10.2024 r.","search_zh":"游泳池水 PB_52_04 edycja 3 z 04.10.2024 r.","test_object_zh":"游泳池水"},{"_id":"6a5dc9b7f1c10c8ce825d1a0","lab_id":"69ad52a3de79e566650fb2e4","country":"PL","accr_number":"AB 573","accr_body":"PCA","test_object":"Kał, wymazy z odbytu","test_object_en":"Faeces, rectal swabs","methodology":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella","methodology_en":"Presence and identification of rods of the genera Salmonella and Shigella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB_55_01 edycja 3 z 02.05.2024 r.","norm_bases":["PB_55_01 edycja 3 z 02.05.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, wymazy z odbytu Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB_55_01 edycja 3 z 02.05.2024 r. Kal, wymazy z odbytu Obecnosc i identyfikacja paleczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB_55_01 edycja 3 z 02.05.2024 r.","categories":["microbiology"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces, rectal swabs Presence and identification of rods of the genera Salmonella and Shigella Culture method with biochemical and serological confirmation PB_55_01 edycja 3 z 02.05.2024 r.","search_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定 培养法结合生化与血清学确认 PB_55_01 edycja 3 z 02.05.2024 r.","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定"}],"has_pdf":true}