🇵🇱 Instytut Badawczy Dróg i Mostów PL
ConstructionElectronics & EMC
Instytut Badawczy Dróg i Mostów is a laboratory accredited by PCA under number AB 547 (Warszawa, Poland). Its accreditation scope covers 8 test methods in the following areas: Construction, Electronics & EMC. Test objects include: Construction works – bridge structures (railway engineering structu…, Test object/product.
At a glance
- Accreditation number: PCA AB 547
- Methods in scope: 8
- Types of test objects: 2
- City: Warszawa, Poland
- Accreditation number
- AB 547
- Accreditation body
- PCA
- Address
- ul. Instytutowa 1
- City
- Warszawa, Poland
- Division
- Laboratorium Badań Konstrukcji Mostowych
What this laboratory tests (2)
- Construction works – bridge structures (railway engineering structures and road engineering structures) — 7 methods
- Test object/product — 1 method
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Test object/product | Type of activity/characteristics tested/method | Dokumenty odniesienia | ||
| 2 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vertical displacements under static load Range do ±50 mm Location of the reference point up to 20 m (vertically) Measurement using displacement sensors |
PB/TM-2/1 wyd. 5 z 12.09.2018 r. | ||
| 3 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vertical and horizontal displacements under static load Vertical displacements do 200 mm Horizontal displacements do 20 mm Location of the reference point up to 500 m (obliquely – vertically and horizontally) Measurement using an automatic electronic tacheometer |
PB/TM-2/4 wyd. 5 z 12.09.2018 r. | ||
| 4 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of support settlements under static load, Range up to 50 mm, Reference point location up to 40 m (horizontally), Measurement using precise levelling | PB/TM-2/3 wyd. 5 z 12.09.2018 r. | ||
| 5 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of unit strains under static load Range ± 2000 μm/m Measurement using electrical resistance strain gauges |
PB/TM-2/2 wyd. 5 z 12.09.2018 r. | ||
| 6 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vertical displacements under dynamic loading Range do ±50 mm Location of the reference point up to 10 m (vertically) Measurement using displacement sensors |
PB/TM-2/1 wyd. 5 z 12.09.2018 r | ||
| 7 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of vibration accelerations of structural elements under dynamic loading amplitudes: ± 10 m/s2 frequencies: (0,5 – 20) Hz Measurement using accelerometers |
PB/TM-2/5 wyd. 2 z 12.09.2018 r. | ||
| 8 | Construction works – bridge structures (railway engineering structures and road engineering structures) | Measurement of unit strains under dynamic load Range ± 2000 μm/m Measurement using electrical resistance strain gauges |
PB/TM-2/2 wyd. 5 z 12.09.2018 r. | ||
Reference standards (7)
Dokumenty odniesienia
PB/TM-2/1 wyd. 5 z 12.09.2018 r
PB/TM-2/1 wyd. 5 z 12.09.2018 r.
PB/TM-2/2 wyd. 5 z 12.09.2018 r.
PB/TM-2/3 wyd. 5 z 12.09.2018 r.
PB/TM-2/4 wyd. 5 z 12.09.2018 r.
PB/TM-2/5 wyd. 2 z 12.09.2018 r.