{"lab":{"_id":"69ad52a3de79e566650fb2ca","accr_number":"AB 547","country":"PL","accr_body":"PCA","address":"ul. Instytutowa 1","categories":["construction","electronics"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":8,"name":"Instytut Badawczy Dróg i Mostów","parse_status":"parsed","parse_version":0,"pdf_files":["AB_547.pdf"],"scope_summary":"","search_text":"ab 547","status":"active","updated_at":"2026-08-19T16:21:02.978Z","valid_from":"","valid_until":"","website":"","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20547,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne obiektów budowlanych","en":"Mechanical tests of building items"}],"issue":{"no":"20","date":"15.01.2026"},"parse_date":"2026-07-20T07:09:42.615Z","parse_source":"script-pdfplumber","map_coord":[52.231958,21.006725],"map_geo":"nominatim-city","lab_division":"Laboratorium Badań Konstrukcji Mostowych","has_en":true,"category_counts":{"construction":7,"electronics":1,"other":1},"category_scores":{"construction":5.44,"electronics":0.11,"other":0.11},"has_zh":true},"methods":[{"_id":"6a5dc9b6f1c10c8ce825ce29","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Przedmiot badań/wyrób","test_object_en":"Test object/product","methodology":"Rodzaj działalności/badane cechy/metoda","methodology_en":"Type of activity/characteristics tested/method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rodzaj działalności/badane cechy/metoda","reference":"Dokumenty odniesienia","norm_bases":["Dokumenty odniesienia"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Przedmiot badan/wyrob Rodzaj dzialalnosci/badane cechy/metoda Dokumenty odniesienia","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Test object/product Type of activity/characteristics tested/method Dokumenty odniesienia","search_zh":"检测对象/产品 活动类别/受检特性/方法 Dokumenty odniesienia","test_object_zh":"检测对象/产品","methodology_zh":"活动类别/受检特性/方法"},{"_id":"6a5dc9b6f1c10c8ce825ce2a","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar przemieszczeń pionowych przy obciążeniu statycznym","methodology_en":"Measurement of vertical displacements under static load","parameters":[{"name":"Zakres","range":"do ±50 mm"},{"name":"Lokalizacja punktu odniesienia do 20 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń"}],"parameters_en":[{"name":"Range","range":"do ±50 mm"},{"name":"Location of the reference point up to 20 m (vertically) Measurement using displacement sensors"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar przemieszczeń pionowych przy obciążeniu statycznym\nZakres:\nZakres do ±50 mm\nLokalizacja punktu odniesienia do 20 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń","reference":"PB/TM-2/1 wyd. 5 z 12.09.2018 r.","norm_bases":["PB/TM-2/1 wyd. 5 z 12.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych przy obciążeniu statycznym\nZakres:\nZakres do ±50 mm\nLokalizacja punktu odniesienia do 20 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń PB/TM-2/1 wyd. 5 z 12.09.2018 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych przy obciazeniu statycznym\nZakres:\nZakres do ±50 mm\nLokalizacja punktu odniesienia do 20 m (w pionie) Pomiar z zastosowaniem czujnikow przemieszczen PB/TM-2/1 wyd. 5 z 12.09.2018 r.","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical displacements under static load Range Location of the reference point up to 20 m (vertically) Measurement using displacement sensors PB/TM-2/1 wyd. 5 z 12.09.2018 r.","parameters_zh":[{"name":"范围","range":"do ±50 mm"},{"name":"Lokalizacja punktu odniesienia do 20 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静载荷下的竖向位移测量 范围 PB/TM-2/1 wyd. 5 z 12.09.2018 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"静载荷下的竖向位移测量"},{"_id":"6a5dc9b6f1c10c8ce825ce2b","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar przemieszczeń pionowych i poziomych przy obciążeniu statycznym","methodology_en":"Measurement of vertical and horizontal displacements under static load","parameters":[{"name":"Przemieszczenia pionowe","range":"do 200 mm"},{"name":"Przemieszczenia poziome","range":"do 20 mm"},{"name":"Lokalizacja punktu odniesienia do 500 m (w skosie – w pionie i w poziomie) Pomiar z zastosowaniem automatycznego tachimetru elektronicznego"}],"parameters_en":[{"name":"Vertical displacements","range":"do 200 mm"},{"name":"Horizontal displacements","range":"do 20 mm"},{"name":"Location of the reference point up to 500 m (obliquely – vertically and horizontally) Measurement using an automatic electronic tacheometer"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar przemieszczeń pionowych i poziomych przy obciążeniu statycznym\nZakres:\nPrzemieszczenia pionowe do 200 mm\nPrzemieszczenia poziome do 20 mm\nLokalizacja punktu odniesienia do 500 m (w skosie – w pionie i w poziomie) Pomiar z zastosowaniem automatycznego tachimetru elektronicznego","reference":"PB/TM-2/4 wyd. 5 z 12.09.2018 r.","norm_bases":["PB/TM-2/4 wyd. 5 z 12.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych i poziomych przy obciążeniu statycznym\nZakres:\nPrzemieszczenia pionowe do 200 mm\nPrzemieszczenia poziome do 20 mm\nLokalizacja punktu odniesienia do 500 m (w skosie – w pionie i w poziomie) Pomiar z zastosowaniem automatycznego tachimetru elektronicznego PB/TM-2/4 wyd. 5 z 12.09.2018 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych i poziomych przy obciazeniu statycznym\nZakres:\nPrzemieszczenia pionowe do 200 mm\nPrzemieszczenia poziome do 20 mm\nLokalizacja punktu odniesienia do 500 m (w skosie – w pionie i w poziomie) Pomiar z zastosowaniem automatycznego tachimetru elektronicznego PB/TM-2/4 wyd. 5 z 12.09.2018 r.","categories":["construction","electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical and horizontal displacements under static load Vertical displacements Horizontal displacements Location of the reference point up to 500 m (obliquely – vertically and horizontally) Measurement using an automatic electronic tacheometer PB/TM-2/4 wyd. 5 z 12.09.2018 r.","search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） PB/TM-2/4 wyd. 5 z 12.09.2018 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）"},{"_id":"6a5dc9b6f1c10c8ce825ce2c","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar osiadań podpór przy obciążeniu statycznym, Zakres do 50 mm, Lokalizacja punktu odniesienia do 40 m (w poziomie), Pomiar z zastosowaniem niwelacji precyzyjnej","methodology_en":"Measurement of support settlements under static load, Range up to 50 mm, Reference point location up to 40 m (horizontally), Measurement using precise levelling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar osiadań podpór przy obciążeniu statycznym, Zakres do 50 mm, Lokalizacja punktu odniesienia do 40 m (w poziomie), Pomiar z zastosowaniem niwelacji precyzyjnej","reference":"PB/TM-2/3 wyd. 5 z 12.09.2018 r.","norm_bases":["PB/TM-2/3 wyd. 5 z 12.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar osiadań podpór przy obciążeniu statycznym, Zakres do 50 mm, Lokalizacja punktu odniesienia do 40 m (w poziomie), Pomiar z zastosowaniem niwelacji precyzyjnej PB/TM-2/3 wyd. 5 z 12.09.2018 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar osiadan podpor przy obciazeniu statycznym, Zakres do 50 mm, Lokalizacja punktu odniesienia do 40 m (w poziomie), Pomiar z zastosowaniem niwelacji precyzyjnej PB/TM-2/3 wyd. 5 z 12.09.2018 r.","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of support settlements under static load, Range up to 50 mm, Reference point location up to 40 m (horizontally), Measurement using precise levelling PB/TM-2/3 wyd. 5 z 12.09.2018 r.","search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） PB/TM-2/3 wyd. 5 z 12.09.2018 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）"},{"_id":"6a5dc9b6f1c10c8ce825ce2d","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar odkształceń jednostkowych przy obciążeniu statycznym","methodology_en":"Measurement of unit strains under static load","parameters":[{"name":"Zakres","range":"± 2000 μm/m"},{"name":"Pomiar z zastosowaniem elektrycznej tensometrii oporowej"}],"parameters_en":[{"name":"Range","range":"± 2000 μm/m"},{"name":"Measurement using electrical resistance strain gauges"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar odkształceń jednostkowych przy obciążeniu statycznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej","reference":"PB/TM-2/2 wyd. 5 z 12.09.2018 r.","norm_bases":["PB/TM-2/2 wyd. 5 z 12.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar odkształceń jednostkowych przy obciążeniu statycznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB/TM-2/2 wyd. 5 z 12.09.2018 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar odksztalcen jednostkowych przy obciazeniu statycznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB/TM-2/2 wyd. 5 z 12.09.2018 r.","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of unit strains under static load Range Measurement using electrical resistance strain gauges PB/TM-2/2 wyd. 5 z 12.09.2018 r.","parameters_zh":[{"name":"范围","range":"± 2000 μm/m"},{"name":"采用电阻应变测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 静荷载下单位变形的测量 范围 采用电阻应变测量的测定 PB/TM-2/2 wyd. 5 z 12.09.2018 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"静荷载下单位变形的测量"},{"_id":"6a5dc9b6f1c10c8ce825ce2e","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym","methodology_en":"Measurement of vertical displacements under dynamic loading","parameters":[{"name":"Zakres","range":"do ±50 mm"},{"name":"Lokalizacja punktu odniesienia do 10 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń"}],"parameters_en":[{"name":"Range","range":"do ±50 mm"},{"name":"Location of the reference point up to 10 m (vertically) Measurement using displacement sensors"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym\nZakres:\nZakres do ±50 mm\nLokalizacja punktu odniesienia do 10 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń","reference":"PB/TM-2/1 wyd. 5 z 12.09.2018 r","norm_bases":["PB/TM-2/1 wyd. 5 z 12.09.2018 r"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przemieszczeń pionowych przy obciążeniu dynamicznym\nZakres:\nZakres do ±50 mm\nLokalizacja punktu odniesienia do 10 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń PB/TM-2/1 wyd. 5 z 12.09.2018 r Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przemieszczen pionowych przy obciazeniu dynamicznym\nZakres:\nZakres do ±50 mm\nLokalizacja punktu odniesienia do 10 m (w pionie) Pomiar z zastosowaniem czujnikow przemieszczen PB/TM-2/1 wyd. 5 z 12.09.2018 r","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vertical displacements under dynamic loading Range Location of the reference point up to 10 m (vertically) Measurement using displacement sensors PB/TM-2/1 wyd. 5 z 12.09.2018 r","parameters_zh":[{"name":"范围","range":"do ±50 mm"},{"name":"Lokalizacja punktu odniesienia do 10 m (w pionie) Pomiar z zastosowaniem czujników przemieszczeń"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下的竖向位移测量 范围 PB/TM-2/1 wyd. 5 z 12.09.2018 r","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"动荷载下的竖向位移测量"},{"_id":"6a5dc9b6f1c10c8ce825ce2f","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar przyspieszeń drgań elementów konstrukcji przy obciążeniu dynamicznym","methodology_en":"Measurement of vibration accelerations of structural elements under dynamic loading","parameters":[{"name":"amplitud: ± 10 m/s2"},{"name":"częstotliwości:","range":"(0,5 – 20) Hz"},{"name":"Pomiar z zastosowaniem akcelerometrów"}],"parameters_en":[{"name":"amplitudes: ± 10 m/s2"},{"name":"frequencies:","range":"(0,5 – 20) Hz"},{"name":"Measurement using accelerometers"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar przyspieszeń drgań elementów konstrukcji przy obciążeniu dynamicznym\nZakres:\namplitud: ± 10 m/s2\nczęstotliwości: (0,5 – 20) Hz\nPomiar z zastosowaniem akcelerometrów","reference":"PB/TM-2/5 wyd. 2 z 12.09.2018 r.","norm_bases":["PB/TM-2/5 wyd. 2 z 12.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar przyspieszeń drgań elementów konstrukcji przy obciążeniu dynamicznym\nZakres:\namplitud: ± 10 m/s2\nczęstotliwości: (0,5 – 20) Hz\nPomiar z zastosowaniem akcelerometrów PB/TM-2/5 wyd. 2 z 12.09.2018 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar przyspieszen drgan elementow konstrukcji przy obciazeniu dynamicznym\nZakres:\namplitud: ± 10 m/s2\nczestotliwosci: (0,5 – 20) Hz\nPomiar z zastosowaniem akcelerometrow PB/TM-2/5 wyd. 2 z 12.09.2018 r.","categories":["construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of vibration accelerations of structural elements under dynamic loading amplitudes: ± 10 m/s2 frequencies: Measurement using accelerometers PB/TM-2/5 wyd. 2 z 12.09.2018 r.","search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下结构构件振动加速度的测量 幅值：± 10 m/s2 采用加速度计的测定 PB/TM-2/5 wyd. 2 z 12.09.2018 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"动荷载下结构构件振动加速度的测量","parameters_zh":[{"name":"幅值：± 10 m/s2"},{"name":"częstotliwości:","range":"(0,5 – 20) Hz"},{"name":"采用加速度计的测定"}]},{"_id":"6a5dc9b6f1c10c8ce825ce30","lab_id":"69ad52a3de79e566650fb2ca","country":"PL","accr_number":"AB 547","accr_body":"PCA","test_object":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie)","test_object_en":"Construction works – bridge structures (railway engineering structures and road engineering structures)","methodology":"Pomiar odkształceń jednostkowych przy obciążeniu dynamicznym","methodology_en":"Measurement of unit strains under dynamic load","parameters":[{"name":"Zakres","range":"± 2000 μm/m"},{"name":"Pomiar z zastosowaniem elektrycznej tensometrii oporowej"}],"parameters_en":[{"name":"Range","range":"± 2000 μm/m"},{"name":"Measurement using electrical resistance strain gauges"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar odkształceń jednostkowych przy obciążeniu dynamicznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej","reference":"PB/TM-2/2 wyd. 5 z 12.09.2018 r.","norm_bases":["PB/TM-2/2 wyd. 5 z 12.09.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inżynieryjne i drogowe obiekty inżynierskie) Pomiar odkształceń jednostkowych przy obciążeniu dynamicznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB/TM-2/2 wyd. 5 z 12.09.2018 r. Obiekty budowlane – konstrukcje mostowe (kolejowe obiekty inzynieryjne i drogowe obiekty inzynierskie) Pomiar odksztalcen jednostkowych przy obciazeniu dynamicznym\nZakres:\nZakres ± 2000 μm/m\nPomiar z zastosowaniem elektrycznej tensometrii oporowej PB/TM-2/2 wyd. 5 z 12.09.2018 r.","categories":["construction"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works – bridge structures (railway engineering structures and road engineering structures) Measurement of unit strains under dynamic load Range Measurement using electrical resistance strain gauges PB/TM-2/2 wyd. 5 z 12.09.2018 r.","parameters_zh":[{"name":"范围","range":"± 2000 μm/m"},{"name":"采用电阻应变测量的测定"}],"search_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物） 动荷载下单位变形的测量 范围 采用电阻应变测量的测定 PB/TM-2/2 wyd. 5 z 12.09.2018 r.","test_object_zh":"建筑物 — 桥梁结构（铁路工程构筑物与公路工程构筑物）","methodology_zh":"动荷载下单位变形的测量"}],"has_pdf":true}