🇵🇱 CHEMWIK Sp. z o.o. PL

PCA AB 508 • Bydgoszcz, Poland • 45 methods

Water & wastewaterEnvironment

CHEMWIK Sp. z o.o. is a laboratory accredited by PCA under number AB 508 (Bydgoszcz, Poland). Its accreditation scope covers 45 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, Wastewater, Sewage sludge, Activated sludge, Sewage sludge, Waste o), code 19 08 05, Wastewater. Most frequently used techniques: Gravimetric method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 508
  • Methods in scope: 45
  • Types of test objects: 11
  • Techniques used: 11
  • City: Bydgoszcz, Poland
Accreditation number
AB 508
Accreditation body
PCA
Address
LABORATORIUM, ul. Toruńska 324 A, 85-880 Bydgoszcz
City
Bydgoszcz, Poland

What this laboratory tests (11)

Analytical techniques used (11)

Accreditation scope — test methods (45)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Biochemical oxygen demand
BOD5, BOD2+5 Range (3 – 3000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019
2 Wastewater Chemical oxygen demand
COD Range (15,0 – 50000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
3 Wastewater Chemical oxygen demand
COD Range (30 – 50000) mg/l O2
Titrimetric method PN-ISO 6060:2006
4 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (0,5 – 50) oC
Automatic method; Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
5 Water, Wastewater Organic nitrogen concentration (calculated) PB-11 edycja nr 10 z dnia 03.11.2025r.
6 Water, Wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
7 Water, Wastewater Total alkalinity
Range (0,4 – 20) mmol/l
Potentiometric titration method PN-EN ISO 9963-1:2001+Ap1:2004
8 Water, Wastewater Electrical conductivity
Range (0,100 – 13) mS/cm
Conductometric method PN-EN 27888:1999
9 Water, Wastewater Kjeldahl nitrogen concentration
Range (1,00 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
10 Water, Wastewater Total nitrogen concentration (calculated) PB-46 edycja nr 01 z dnia 18.09.2025r.
11 Water, Wastewater Total nitrogen concentration
Range (1,00 – 400) mg/l
Spectrophotometric method PB-03 edycja nr 09 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338
12 Water, Wastewater Sulfate concentration
Range (40,0 – 2500) mg/l
Spectrophotometric method PB-07 edycja nr 07 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 153
13 Water, Wastewater Sulfate concentration
Range (10 – 2500) mg/l
Gravimetric method PN-ISO 9280:2002
14 Water, Wastewater Dry residue
Range (100 – 25 000) mg/l
Gravimetric method PN-78/C-04541
15 Water, Wastewater Dry residue
Range (100 – 25 000) mg/l Dissolved solids (calculated)
Gravimetric method PB-22 edycja nr 06 z dnia 31.05.2019 r.
16 Water, Wastewater Biochemical oxygen demand
BOD5, BOD2+5 Range (3 – 3000) mg/l O2
Electrochemical method PN-EN 1899-1:2002
17 Water, Wastewater Total organic carbon concentration (TOC)
Range (10,0 – 1500) mg/l
Spectrophotometric method PB-21 edycja nr 05 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386
18 Water, Wastewater Adsorbable organically bound halogens (AOX) concentration
Range (0,025 – 50) mg/l
Coulometric titration method PN-EN ISO 9562:2007
19 Water, Wastewater Total organic carbon concentration (TOC)
Range (5,00 – 5000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
20 Water, Wastewater Chloride concentration
Range (1,00 – 15000) mg/l
Spectrophotometric method PB-04 edycja nr 06 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 311
21 Water, Wastewater Ammonium nitrogen concentration
Range (0,040 – 40,0 ) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
22 Water, Wastewater Ammonium nitrogen concentration
Range (2,00 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
23 Water, Wastewater Nitrite nitrogen concentration
Range (0,001 – 20,0) mg/l
Spectrophotometric method PN-EN 26777:1999
24 Water, Wastewater Nitrate nitrogen concentration
Range (0,100 – 100) mg/l
Spectrophotometric method PN-82/C-04576.08
25 Water, Wastewater Chloride concentration
Range (5,00 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
26 Water, Wastewater Phosphate concentration
Range (0,020 – 300) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
27 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
28 Water, Wastewater Total phosphorus concentration
Range (0,100 – 300) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
29 Water, Wastewater, Activated sludge Total suspended solids (TSS)
Range (2,0 – 20 000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
30 Sewage sludge, Activated sludge Moisture (calculated) PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4
31 Sewage sludge, Activated sludge Dry residue
Range (3 – 350) g/kg
Gravimetric method PN-EN 12880:2004
32 Sewage sludge, Activated sludge pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
33 Sewage sludge, Activated sludge Dry residue
Range (3 – 350) g/kg
Gravimetric method PN-EN 15934:2013- 02
34 Sewage sludge, Activated sludge Loss on ignition
Range (2,0 – 95,0) % Residue on ignition (calculated)
Gravimetric method PN-EN 15935:2022- 01
35 Sewage sludge, Waste o), code 19 08 05 Dry residue
Range (3 – 350) g/kg
Gravimetric method PN-EN 12880:2004
36 Sewage sludge, Waste o), code 19 08 05 pH - in H2O
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
37 Sewage sludge, Waste o), code 19 08 05 Dry residue
Range (3 – 350) g/kg
Gravimetric method PN-EN 15934:2013- 02
38 Sewage sludge, Waste o), code 19 08 05 Loss on ignition of dry matter (LOI) / Residue on ignition
Range (2,0 – 95,0) %
Gravimetric method PN-EN 15935:2022- 01
39 Sewage sludge (supernatant liquid) Total alkalinity
Range (2,0 – 200) mmol/l
Potentiometric titration method PB-30 edycja nr 05 z dnia 31.05.2019 r.
40 Activated sludge Relative volume
Range (100 – 1000) ml/l Sludge volume index (calculated)
Volumetric-sedimentation method PN-EN 14702-1:2008
41 Activated sludge Dry matter
Range (1,0 – 10) g/l
Gravimetric method PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2
42 Sewage sludge Dry matter
Range (3,00 – 350) g/kg
Gravimetric method PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3
43 Activated sludge, Sewage sludge, Wasteo), code 19 08 05 Sampling for chemical and physical testing PN- ISO 5667-13:2011
44 Process water Sampling for chemical and physical testing PB-41 edycja nr 04 z dnia 31.05.2019 r.
45 Water Sampling for chemical and physical testing Temperature of the water sample taken
Range (0,5 – 50) oC
PB-40 edycja nr 04 z dnia 31.05.2019 r. | PN-77/C-04584

Reference standards (46)

PB-03 edycja nr 09 z dnia 25.05.2023r.
PB-04 edycja nr 06 z dnia 31.05.2019 r.
PB-07 edycja nr 07 z dnia 25.05.2023r.
PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2
PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4
PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3
PB-11 edycja nr 10 z dnia 03.11.2025r.
PB-21 edycja nr 05 z dnia 31.05.2019 r.
PB-22 edycja nr 06 z dnia 31.05.2019 r.
PB-30 edycja nr 05 z dnia 31.05.2019 r.
PB-40 edycja nr 04 z dnia 31.05.2019 r.
PB-41 edycja nr 04 z dnia 31.05.2019 r.
PB-46 edycja nr 01 z dnia 18.09.2025r.
PN- ISO 5667-13:2011
PN-77/C-04584
PN-78/C-04541
PN-82/C-04576.08
PN-EN 12880:2004
PN-EN 14702-1:2008
PN-EN 1484:1999
PN-EN 15934:2013- 02
PN-EN 15935:2022- 01
PN-EN 1899-1:2002
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019
PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
PN-EN ISO 9562:2007
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338
na podstawie testu kuwetowego Hach Lange LCK 153
na podstawie testu kuwetowego Hach Lange LCK 311
na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386