{"lab":{"_id":"69ad52a3de79e566650fb283","accr_number":"AB 508","country":"PL","accr_body":"PCA","address":"LABORATORIUM, ul. Toruńska 324 A, 85-880 Bydgoszcz","categories":["water","environment"],"city":"Bydgoszcz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":45,"name":"CHEMWIK Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_508.pdf"],"scope_summary":"","search_text":"chemwik sp. z o.o. laboratorium, ul. toruńska 324 a, 85-880 bydgoszcz water other pharma electronics environment","status":"active","updated_at":"2026-03-08T14:51:21.720Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:21.720Z","location":{"type":"Point","coordinates":[18.0084,53.1235]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20508,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, osadów ściekowych, odpadów","en":"Chemical tests and sampling of water, sewage, sediments, waste"},{"codes":"N/28/P; N/30/P; N/32/P","pl":"Badanie właściwości fizycznych i pobieranie próbek wody, ścieków, osadów ściekowych, odpadów","en":"Tests of physical properties and sampling of water, sewage, sediments, waste"}],"issue":{"no":"21","date":"14.01.2026"},"parse_date":"2026-07-20T07:09:40.613Z","parse_source":"script-pdfplumber","map_coord":[53.105218,18.120682],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":45,"environment":5},"category_scores":{"water":40.5,"environment":0.5},"has_zh":true},"methods":[{"_id":"6a5dc9b4f1c10c8ce825c686","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5, BZT2+5"},{"name":"Zakres","range":"(3 – 3000) mg/l O2"}],"parameters_en":[{"name":"BOD5, BOD2+5"},{"name":"Range","range":"(3 – 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019","norm_bases":["PN-EN ISO 5815-1:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Electrochemical method BOD5, BOD2+5 Range PN-EN ISO 5815-1:2019","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BOD5、BOD2+5"},{"name":"范围","range":"(3 – 3000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 BOD5、BOD2+5 范围 PN-EN ISO 5815-1:2019","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9b4f1c10c8ce825c687","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(15,0 – 50000) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(15,0 – 50000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (15,0 – 50000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (15,0 – 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (15,0 – 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand Spectrophotometric method COD Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(15,0 – 50000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 化学需氧量（COD） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9b4f1c10c8ce825c688","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(30 – 50000) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(30 – 50000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (30 – 50000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (30 – 50000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (30 – 50000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand Titrimetric method COD Range PN-ISO 6060:2006","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(30 – 50000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 滴定法 化学需氧量（COD） 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9b4f1c10c8ce825c689","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 – 50) oC"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,5 – 50) oC"}],"technique":"Metoda automatyczna; Metoda manualna","techniques":["Metoda automatyczna","Metoda manualna"],"technique_en":"Automatic method; Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) oC\nMetoda automatyczna; Metoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) oC\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,5 – 50) oC\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method; Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,5 – 50) oC"}],"search_zh":"污水 化学与物理检测用样品采集 自动法；手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"自动法；手工法"},{"_id":"6a5dc9b4f1c10c8ce825c68a","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu organicznego (z obliczeń)","methodology_en":"Organic nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu organicznego (z obliczeń)","reference":"PB-11 edycja nr 10 z dnia 03.11.2025r.","norm_bases":["PB-11 edycja nr 10 z dnia 03.11.2025r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu organicznego (z obliczeń) PB-11 edycja nr 10 z dnia 03.11.2025r. Woda, Scieki Stezenie azotu organicznego (z obliczen) PB-11 edycja nr 10 z dnia 03.11.2025r.","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Organic nitrogen concentration (calculated) PB-11 edycja nr 10 z dnia 03.11.2025r.","search_zh":"水、污水 有机氮浓度（由计算得出） PB-11 edycja nr 10 z dnia 03.11.2025r.","test_object_zh":"水、污水","methodology_zh":"有机氮浓度（由计算得出）"},{"_id":"6a5dc9b4f1c10c8ce825c68b","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c68c","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,4 – 20) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,4 – 20) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zasadowość ogólna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Scieki Zasadowosc ogolna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total alkalinity Potentiometric titration method Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,4 – 20) mmol/l"}],"search_zh":"水、污水 总碱度 电位滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"水、污水","methodology_zh":"总碱度"},{"_id":"6a5dc9b4f1c10c8ce825c68d","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(0,100 – 13) mS/cm"}],"parameters_en":[{"name":"Range","range":"(0,100 – 13) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,100 – 13) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (0,100 – 13) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (0,100 – 13) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,100 – 13) mS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c68e","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c68f","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-46 edycja nr 01 z dnia 18.09.2025r.","norm_bases":["PB-46 edycja nr 01 z dnia 18.09.2025r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-46 edycja nr 01 z dnia 18.09.2025r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-46 edycja nr 01 z dnia 18.09.2025r.","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-46 edycja nr 01 z dnia 18.09.2025r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-46 edycja nr 01 z dnia 18.09.2025r.","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c690","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,00 – 400) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 edycja nr 09 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338","norm_bases":["PB-03 edycja nr 09 z dnia 25.05.2023r.","na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (1,00 – 400) mg/l\nMetoda spektrofotometryczna PB-03 edycja nr 09 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338 Woda, Scieki Stezenie azotu ogolnego\nZakres (1,00 – 400) mg/l\nMetoda spektrofotometryczna PB-03 edycja nr 09 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration Spectrophotometric method Range PB-03 edycja nr 09 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 400) mg/l"}],"search_zh":"水、污水 总氮浓度 分光光度法 范围 PB-03 edycja nr 09 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 138, LCK 238, LCK 338","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c691","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(40,0 – 2500) mg/l"}],"parameters_en":[{"name":"Range","range":"(40,0 – 2500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (40,0 – 2500) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 edycja nr 07 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 153","norm_bases":["PB-07 edycja nr 07 z dnia 25.05.2023r.","na podstawie testu kuwetowego Hach Lange LCK 153"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (40,0 – 2500) mg/l\nMetoda spektrofotometryczna PB-07 edycja nr 07 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 153 Woda, Scieki Stezenie siarczanow\nZakres (40,0 – 2500) mg/l\nMetoda spektrofotometryczna PB-07 edycja nr 07 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 153","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Spectrophotometric method Range PB-07 edycja nr 07 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 153","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40,0 – 2500) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 分光光度法 范围 PB-07 edycja nr 07 z dnia 25.05.2023r. | na podstawie testu kuwetowego Hach Lange LCK 153","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c692","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 2500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 2500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 – 2500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10 – 2500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 2500) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c693","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(100 – 25 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(100 – 25 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (100 – 25 000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Sucha pozostałość\nZakres (100 – 25 000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, Scieki Sucha pozostalosc\nZakres (100 – 25 000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dry residue Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(100 – 25 000) mg/l"}],"search_zh":"水、污水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"干残渣"},{"_id":"6a5dc9b4f1c10c8ce825c694","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(100 – 25 000) mg/l"},{"name":"Substancje rozpuszczone (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(100 – 25 000) mg/l"},{"name":"Dissolved solids (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres:\nZakres (100 – 25 000) mg/l\nSubstancje rozpuszczone (z obliczeń)\nMetoda wagowa","reference":"PB-22 edycja nr 06 z dnia 31.05.2019 r.","norm_bases":["PB-22 edycja nr 06 z dnia 31.05.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Sucha pozostałość\nZakres:\nZakres (100 – 25 000) mg/l\nSubstancje rozpuszczone (z obliczeń)\nMetoda wagowa PB-22 edycja nr 06 z dnia 31.05.2019 r. Woda, Scieki Sucha pozostalosc\nZakres:\nZakres (100 – 25 000) mg/l\nSubstancje rozpuszczone (z obliczen)\nMetoda wagowa PB-22 edycja nr 06 z dnia 31.05.2019 r.","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dry residue Gravimetric method Range Dissolved solids (calculated) PB-22 edycja nr 06 z dnia 31.05.2019 r.","parameters_zh":[{"name":"范围","range":"(100 – 25 000) mg/l"},{"name":"Substancje rozpuszczone (z obliczeń)"}],"search_zh":"水、污水 干残渣 重量法 范围 PB-22 edycja nr 06 z dnia 31.05.2019 r.","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"干残渣"},{"_id":"6a5dc9b4f1c10c8ce825c695","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5, BZT2+5"},{"name":"Zakres","range":"(3 – 3000) mg/l O2"}],"parameters_en":[{"name":"BOD5, BOD2+5"},{"name":"Range","range":"(3 – 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-1:2002","norm_bases":["PN-EN 1899-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-1:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-1:2002","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5, BOD2+5 Range PN-EN 1899-1:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BOD5、BOD2+5"},{"name":"范围","range":"(3 – 3000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BOD5、BOD2+5 范围 PN-EN 1899-1:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c696","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(10,0 – 1500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10,0 – 1500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (10,0 – 1500) mg/l\nMetoda spektrofotometryczna","reference":"PB-21 edycja nr 05 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386","norm_bases":["PB-21 edycja nr 05 z dnia 31.05.2019 r.","na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (10,0 – 1500) mg/l\nMetoda spektrofotometryczna PB-21 edycja nr 05 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (10,0 – 1500) mg/l\nMetoda spektrofotometryczna PB-21 edycja nr 05 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration (TOC) Spectrophotometric method Range PB-21 edycja nr 05 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386","parameters_zh":[{"name":"范围","range":"(10,0 – 1500) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 分光光度法 范围 PB-21 edycja nr 05 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 385, LCK 386","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a5dc9b4f1c10c8ce825c697","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie adsorbowalnych związków chloroorganicznych (AOX)","methodology_en":"Adsorbable organically bound halogens (AOX) concentration","parameters":[{"name":"Zakres","range":"(0,025 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 – 50) mg/l"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"technique_en":"Coulometric titration method","computed":[],"computed_en":[],"activity":"Stężenie adsorbowalnych związków chloroorganicznych (AOX)\nZakres (0,025 – 50) mg/l\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 9562:2007","norm_bases":["PN-EN ISO 9562:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie adsorbowalnych związków chloroorganicznych (AOX)\nZakres (0,025 – 50) mg/l\nMetoda miareczkowania kulometrycznego PN-EN ISO 9562:2007 Woda, Scieki Stezenie adsorbowalnych zwiazkow chloroorganicznych (AOX)\nZakres (0,025 – 50) mg/l\nMetoda miareczkowania kulometrycznego PN-EN ISO 9562:2007","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Adsorbable organically bound halogens (AOX) concentration Coulometric titration method Range PN-EN ISO 9562:2007","parameters_zh":[{"name":"范围","range":"(0,025 – 50) mg/l"}],"search_zh":"水、污水 可吸附有机卤化物（AOX）浓度 库仑滴定法 范围 PN-EN ISO 9562:2007","test_object_zh":"水、污水","technique_zh":"库仑滴定法","methodology_zh":"可吸附有机卤化物（AOX）浓度"},{"_id":"6a5dc9b4f1c10c8ce825c698","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(5,00 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 5000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (5,00 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (5,00 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (5,00 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration (TOC) High-temperature combustion with IR detection Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(5,00 – 5000) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a5dc9b4f1c10c8ce825c699","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(1,00 – 15000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 15000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (1,00 – 15000) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 edycja nr 06 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 311","norm_bases":["PB-04 edycja nr 06 z dnia 31.05.2019 r.","na podstawie testu kuwetowego Hach Lange LCK 311"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (1,00 – 15000) mg/l\nMetoda spektrofotometryczna PB-04 edycja nr 06 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 311 Woda, Scieki Stezenie chlorkow\nZakres (1,00 – 15000) mg/l\nMetoda spektrofotometryczna PB-04 edycja nr 06 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 311","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Spectrophotometric method Range PB-04 edycja nr 06 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 311","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 15000) mg/l"}],"search_zh":"水、污水 氯化物浓度 分光光度法 范围 PB-04 edycja nr 06 z dnia 31.05.2019 r. | na podstawie testu kuwetowego Hach Lange LCK 311","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c69a","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,040 – 40,0 ) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 40,0 ) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,040 – 40,0 ) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,040 – 40,0 ) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,040 – 40,0 ) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 40,0 ) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c69b","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (2,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (2,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (2,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 1000) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c69c","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,001 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,001 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,001 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,001 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 20,0) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c69d","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,100 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,100 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,100 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,100 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,100 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 100) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c69e","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c69f","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforanów","methodology_en":"Phosphate concentration","parameters":[{"name":"Zakres","range":"(0,020 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforanów\nZakres (0,020 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforanów\nZakres (0,020 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforanow\nZakres (0,020 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,020 – 300) mg/l"}],"search_zh":"水、污水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"磷酸盐浓度"},{"_id":"6a5dc9b4f1c10c8ce825c6a0","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c6a1","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,100 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,100 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,100 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,100 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,100 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 300) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b4f1c10c8ce825c6a2","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda, Ścieki, Osad czynny","test_object_en":"Water, Wastewater, Activated sludge","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 20 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 20 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 20 000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, Osad czynny Zawiesiny ogólne\nZakres (2,0 – 20 000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki, Osad czynny Zawiesiny ogolne\nZakres (2,0 – 20 000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, Activated sludge Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 20 000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9b4f1c10c8ce825c6a3","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Osad czynny","test_object_en":"Sewage sludge, Activated sludge","methodology":"Wilgotność (z obliczeń)","methodology_en":"Moisture (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wilgotność (z obliczeń)","reference":"PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4","norm_bases":["PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Osad czynny Wilgotność (z obliczeń) PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4 Osady sciekowe, Osad czynny Wilgotnosc (z obliczen) PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Activated sludge Moisture (calculated) PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4","search_zh":"污水污泥、活性污泥 PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.4","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6a4","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Osad czynny","test_object_en":"Sewage sludge, Activated sludge","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(3 – 350) g/kg"}],"parameters_en":[{"name":"Range","range":"(3 – 350) g/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Osad czynny Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe, Osad czynny Sucha pozostalosc\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Activated sludge Dry residue Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(3 – 350) g/kg"}],"search_zh":"污水污泥、活性污泥 干残渣 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6a5","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Osad czynny","test_object_en":"Sewage sludge, Activated sludge","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Osad czynny pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe, Osad czynny pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Activated sludge pH Potentiometric method Range PN-EN ISO 10390:2022-09","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"污水污泥、活性污泥 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6a6","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Osad czynny","test_object_en":"Sewage sludge, Activated sludge","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(3 – 350) g/kg"}],"parameters_en":[{"name":"Range","range":"(3 – 350) g/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa","reference":"PN-EN 15934:2013- 02","norm_bases":["PN-EN 15934:2013- 02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Osad czynny Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 15934:2013- 02 Osady sciekowe, Osad czynny Sucha pozostalosc\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 15934:2013- 02","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Activated sludge Dry residue Gravimetric method Range PN-EN 15934:2013- 02","parameters_zh":[{"name":"范围","range":"(3 – 350) g/kg"}],"search_zh":"污水污泥、活性污泥 干残渣 重量法 范围 PN-EN 15934:2013- 02","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6a7","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Osad czynny","test_object_en":"Sewage sludge, Activated sludge","methodology":"Strata podczas prażenia","methodology_en":"Loss on ignition","parameters":[{"name":"Zakres","range":"(2,0 – 95,0) %"},{"name":"Pozostałość po prażeniu (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(2,0 – 95,0) %"},{"name":"Residue on ignition (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata podczas prażenia\nZakres:\nZakres (2,0 – 95,0) %\nPozostałość po prażeniu (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022- 01","norm_bases":["PN-EN 15935:2022- 01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Osad czynny Strata podczas prażenia\nZakres:\nZakres (2,0 – 95,0) %\nPozostałość po prażeniu (z obliczeń)\nMetoda wagowa PN-EN 15935:2022- 01 Osady sciekowe, Osad czynny Strata podczas prazenia\nZakres:\nZakres (2,0 – 95,0) %\nPozostalosc po prazeniu (z obliczen)\nMetoda wagowa PN-EN 15935:2022- 01","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Activated sludge Loss on ignition Gravimetric method Range Residue on ignition (calculated) PN-EN 15935:2022- 01","parameters_zh":[{"name":"范围","range":"(2,0 – 95,0) %"},{"name":"Pozostałość po prażeniu (z obliczeń)"}],"search_zh":"污水污泥、活性污泥 重量法 范围 PN-EN 15935:2022- 01","technique_zh":"重量法","test_object_zh":"污水污泥、活性污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6a8","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Odpady o), kod 19 08 05","test_object_en":"Sewage sludge, Waste o), code 19 08 05","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(3 – 350) g/kg"}],"parameters_en":[{"name":"Range","range":"(3 – 350) g/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady o), kod 19 08 05 Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe, Odpady o), kod 19 08 05 Sucha pozostalosc\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 12880:2004","categories":["water","environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste o), code 19 08 05 Dry residue Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(3 – 350) g/kg"}],"search_zh":"污水污泥、废物 o)，代码 19 08 05 干残渣 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"污水污泥、废物 o)，代码 19 08 05"},{"_id":"6a5dc9b4f1c10c8ce825c6a9","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Odpady o), kod 19 08 05","test_object_en":"Sewage sludge, Waste o), code 19 08 05","methodology":"pH - w H2O","methodology_en":"pH - in H2O","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w H2O\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady o), kod 19 08 05 pH - w H2O\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe, Odpady o), kod 19 08 05 pH - w H2O\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste o), code 19 08 05 pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"污水污泥、废物 o)，代码 19 08 05 pH - 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","methodology_zh":"pH - 于 H2O 中","test_object_zh":"污水污泥、废物 o)，代码 19 08 05"},{"_id":"6a5dc9b4f1c10c8ce825c6aa","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Odpady o), kod 19 08 05","test_object_en":"Sewage sludge, Waste o), code 19 08 05","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(3 – 350) g/kg"}],"parameters_en":[{"name":"Range","range":"(3 – 350) g/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa","reference":"PN-EN 15934:2013- 02","norm_bases":["PN-EN 15934:2013- 02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady o), kod 19 08 05 Sucha pozostałość\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 15934:2013- 02 Osady sciekowe, Odpady o), kod 19 08 05 Sucha pozostalosc\nZakres (3 – 350) g/kg\nMetoda wagowa PN-EN 15934:2013- 02","categories":["water","environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste o), code 19 08 05 Dry residue Gravimetric method Range PN-EN 15934:2013- 02","parameters_zh":[{"name":"范围","range":"(3 – 350) g/kg"}],"search_zh":"污水污泥、废物 o)，代码 19 08 05 干残渣 重量法 范围 PN-EN 15934:2013- 02","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"污水污泥、废物 o)，代码 19 08 05"},{"_id":"6a5dc9b4f1c10c8ce825c6ab","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe, Odpady o), kod 19 08 05","test_object_en":"Sewage sludge, Waste o), code 19 08 05","methodology":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu","methodology_en":"Loss on ignition of dry matter (LOI) / Residue on ignition","parameters":[{"name":"Zakres","range":"(2,0 – 95,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu\nZakres (2,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022- 01","norm_bases":["PN-EN 15935:2022- 01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady o), kod 19 08 05 Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu\nZakres (2,0 – 95,0) %\nMetoda wagowa PN-EN 15935:2022- 01 Osady sciekowe, Odpady o), kod 19 08 05 Straty przy prazeniu suchej masy (LOI) / Pozostalosc po prazeniu\nZakres (2,0 – 95,0) %\nMetoda wagowa PN-EN 15935:2022- 01","categories":["water","environment"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste o), code 19 08 05 Loss on ignition of dry matter (LOI) / Residue on ignition Gravimetric method Range PN-EN 15935:2022- 01","parameters_zh":[{"name":"范围","range":"(2,0 – 95,0) %"}],"search_zh":"污水污泥、废物 o)，代码 19 08 05 干物质烧失量（LOI）/ 灼烧残渣 重量法 范围 PN-EN 15935:2022- 01","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣","test_object_zh":"污水污泥、废物 o)，代码 19 08 05"},{"_id":"6a5dc9b4f1c10c8ce825c6ac","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe (ciecz nadosadowa)","test_object_en":"Sewage sludge (supernatant liquid)","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(2,0 – 200) mmol/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 200) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (2,0 – 200) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PB-30 edycja nr 05 z dnia 31.05.2019 r.","norm_bases":["PB-30 edycja nr 05 z dnia 31.05.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe (ciecz nadosadowa) Zasadowość ogólna\nZakres (2,0 – 200) mmol/l\nMetoda miareczkowania potencjometrycznego PB-30 edycja nr 05 z dnia 31.05.2019 r. Osady sciekowe (ciecz nadosadowa) Zasadowosc ogolna\nZakres (2,0 – 200) mmol/l\nMetoda miareczkowania potencjometrycznego PB-30 edycja nr 05 z dnia 31.05.2019 r.","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge (supernatant liquid) Total alkalinity Potentiometric titration method Range PB-30 edycja nr 05 z dnia 31.05.2019 r.","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mmol/l"}],"search_zh":"总碱度 电位滴定法 范围 PB-30 edycja nr 05 z dnia 31.05.2019 r.","technique_zh":"电位滴定法","methodology_zh":"总碱度"},{"_id":"6a5dc9b4f1c10c8ce825c6ad","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osad czynny","test_object_en":"Activated sludge","methodology":"Objętość względna","methodology_en":"Relative volume","parameters":[{"name":"Zakres","range":"(100 – 1000) ml/l"},{"name":"Indeks objętościowy osadu (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(100 – 1000) ml/l"},{"name":"Sludge volume index (calculated)"}],"technique":"Metoda objętościowo-sedymentacyjna","techniques":["Metoda objętościowo-sedymentacyjna"],"technique_en":"Volumetric-sedimentation method","computed":[],"computed_en":[],"activity":"Objętość względna\nZakres:\nZakres (100 – 1000) ml/l\nIndeks objętościowy osadu (z obliczeń)\nMetoda objętościowo-sedymentacyjna","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osad czynny Objętość względna\nZakres:\nZakres (100 – 1000) ml/l\nIndeks objętościowy osadu (z obliczeń)\nMetoda objętościowo-sedymentacyjna PN-EN 14702-1:2008 Osad czynny Objetosc wzgledna\nZakres:\nZakres (100 – 1000) ml/l\nIndeks objetosciowy osadu (z obliczen)\nMetoda objetosciowo-sedymentacyjna PN-EN 14702-1:2008","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Activated sludge Relative volume Volumetric-sedimentation method Range Sludge volume index (calculated) PN-EN 14702-1:2008","parameters_zh":[{"name":"范围","range":"(100 – 1000) ml/l"},{"name":"污泥容积指数（由计算得出）"}],"search_zh":"活性污泥 相对体积 范围 污泥容积指数（由计算得出） PN-EN 14702-1:2008","test_object_zh":"活性污泥","methodology_zh":"相对体积"},{"_id":"6a5dc9b4f1c10c8ce825c6ae","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osad czynny","test_object_en":"Activated sludge","methodology":"Sucha masa","methodology_en":"Dry matter","parameters":[{"name":"Zakres","range":"(1,0 – 10) g/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 10) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha masa\nZakres (1,0 – 10) g/l\nMetoda wagowa","reference":"PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2","norm_bases":["PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osad czynny Sucha masa\nZakres (1,0 – 10) g/l\nMetoda wagowa PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2 Osad czynny Sucha masa\nZakres (1,0 – 10) g/l\nMetoda wagowa PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Activated sludge Dry matter Gravimetric method Range PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(1,0 – 10) g/l"}],"search_zh":"活性污泥 干物质 重量法 范围 PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt. 10.1,10.2","technique_zh":"重量法","test_object_zh":"活性污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6af","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha masa","methodology_en":"Dry matter","parameters":[{"name":"Zakres","range":"(3,00 – 350) g/kg"}],"parameters_en":[{"name":"Range","range":"(3,00 – 350) g/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha masa\nZakres (3,00 – 350) g/kg\nMetoda wagowa","reference":"PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3","norm_bases":["PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha masa\nZakres (3,00 – 350) g/kg\nMetoda wagowa PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3 Osady sciekowe Sucha masa\nZakres (3,00 – 350) g/kg\nMetoda wagowa PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry matter Gravimetric method Range PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(3,00 – 350) g/kg"}],"search_zh":"污泥 干物质 重量法 范围 PB-08 edycja nr 07 z dnia 31.05.2019 r., pkt.10.3","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9b4f1c10c8ce825c6b0","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Osad czynny, Osady ściekowe, Odpadyo), kod 19 08 05","test_object_en":"Activated sludge, Sewage sludge, Wasteo), code 19 08 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN- ISO 5667-13:2011","norm_bases":["PN- ISO 5667-13:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osad czynny, Osady ściekowe, Odpadyo), kod 19 08 05 Pobieranie próbek do badań chemicznych i fizycznych PN- ISO 5667-13:2011 Osad czynny, Osady sciekowe, Odpadyo), kod 19 08 05 Pobieranie probek do badan chemicznych i fizycznych PN- ISO 5667-13:2011","categories":["water","environment"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Activated sludge, Sewage sludge, Wasteo), code 19 08 05 Sampling for chemical and physical testing PN- ISO 5667-13:2011","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN- ISO 5667-13:2011"},{"_id":"6a5dc9b4f1c10c8ce825c6b1","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda technologiczna","test_object_en":"Process water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-41 edycja nr 04 z dnia 31.05.2019 r.","norm_bases":["PB-41 edycja nr 04 z dnia 31.05.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda technologiczna Pobieranie próbek do badań chemicznych i fizycznych PB-41 edycja nr 04 z dnia 31.05.2019 r. Woda technologiczna Pobieranie probek do badan chemicznych i fizycznych PB-41 edycja nr 04 z dnia 31.05.2019 r.","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Process water Sampling for chemical and physical testing PB-41 edycja nr 04 z dnia 31.05.2019 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-41 edycja nr 04 z dnia 31.05.2019 r."},{"_id":"6a5dc9b4f1c10c8ce825c6b2","lab_id":"69ad52a3de79e566650fb283","country":"PL","accr_number":"AB 508","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(0,5 – 50) oC"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) oC","reference":"PB-40 edycja nr 04 z dnia 31.05.2019 r. | PN-77/C-04584","norm_bases":["PB-40 edycja nr 04 z dnia 31.05.2019 r.","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) oC PB-40 edycja nr 04 z dnia 31.05.2019 r. | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,5 – 50) oC PB-40 edycja nr 04 z dnia 31.05.2019 r. | PN-77/C-04584","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PB-40 edycja nr 04 z dnia 31.05.2019 r. | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0,5 – 50) oC"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PB-40 edycja nr 04 z dnia 31.05.2019 r. | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"}],"has_pdf":true}