🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 500 • Tychy, Poland • 40 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 500 (Tychy, Poland). Its accreditation scope covers 40 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water, Faeces, Biological indicators for monitoring sterilisation effectiveness (S…. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 500
  • Methods in scope: 40
  • Types of test objects: 6
  • Techniques used: 12
  • City: Tychy, Poland
Accreditation number
AB 500
Accreditation body
PCA
Address
W TYCHACH, ul. Budowlanych 131, 43-100 Tychy
City
Tychy, Poland

What this laboratory tests (6)

Analytical techniques used (12)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (40)

No. Test object Methodology / Parameters Technique Reference document
Oddział Laboratoryjny, Sekcja Badań Higieny Komunalnej i Środowiska
1 Water, water intended for human consumption Nitrite nitrogen concentration
Range (0,015 – 0,300) mg/l NNO2 Nitrite concentration Range (0,050 – 1,00) mg/l NO2
Spectrophotometric method PN-EN 26777:1999
2 Water, water intended for human consumption Ammonium nitrogen concentration
Range (0,05 – 10,0) mg/l NNH4 Range (0,07 – 13,0) mg/l NH4
Spectrophotometric method PN-C-04576-4:1994
3 Water, water intended for human consumption Nitrate nitrogen concentration
Range (0,1 – 50) mg/l NNO3 Nitrate concentration Range (0,45 – 221) mg/l NO3
Spectrophotometric method PN-82/C-04576.08
4 Water, water intended for human consumption Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
5 Water, water intended for human consumption Permanganate index (oxidisability)
Range (1,1 – 30) mg/l
Titrimetric method PN-EN ISO 8467:2001
6 Water, water intended for human consumption Total calcium and magnesium concentration (hardness)
Range (0,05 – 10) mmol/l Range (5,0 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
7 Water, water intended for human consumption Iron concentration
Range (0,06 – 25,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
8 Water, water intended for human consumption Turbidity
Range (0,10 – 80) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water, water intended for human consumption pH
Range 2,0 – 11,0
Potentiometric method PN-EN ISO 10523:2012
10 Water, water intended for human consumption Electrical conductivity
Range 100 µS/cm − 3000 µS/cm
Conductometric method PN-EN 27888:1999
11 Water, water intended for human consumption Colour
Range (3,0 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015
12 Water intended for human consumption Free chlorine concentration
Range (0,10 – 3,0) mg/l
Regulated area: badania/pomiary wykonywane w terenie
Colorimetric method OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.
13 Swimming pool water Nitrate nitrogen concentration
Range (0,1 – 50) mg/l NNO3 Nitrate concentration Range (0,45 – 221) mg/l NO3
Spectrophotometric method PN-82/C-04576.08
14 Swimming pool water Permanganate index (oxidisability)
Range (1,1 – 30) mg/l
Titrimetric method PN-EN ISO 8467:2001
15 Swimming pool water Iron concentration
Range (0,07 – 25,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
16 Swimming pool water pH
Range 2,0 – 11,0
Potentiometric method PN-EN ISO 10523:2012
17 Swimming pool water Oxidation-reduction (redox) potential referred to an Ag/AgCl 3,5 mol/l KCl electrode
Range (200 – 1000) mV
Regulated area: badania/pomiary wykonywane w terenie
Potentiometric method OL/KŚ/PB-03 wyd. 5 z dn. 09.01.2025 r.
18 Swimming pool water Total chlorine concentration
Range (0,10 – 3,0) mg/l
Regulated area: badania/pomiary wykonywane w terenie
Colorimetric method OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.
19 Swimming pool water Free chlorine concentration
Range (0,10 – 3,0) mg/l
Regulated area: badania/pomiary wykonywane w terenie
Colorimetric method OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.
20 Swimming pool water Combined chlorine concentration (calculated)
Regulated area: badania/pomiary wykonywane w terenie
OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.
21 Swimming pool water Turbidity
Range (0,10 – 80) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
22 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
23 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
24 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
25 Water, water intended for human consumption Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +AP1:2019-12
26 Water, water intended for human consumption Total count of microorganisms at a temperature of (22)°C Plate method (pour plate) PN-EN ISO 6222:2004
27 Water, water intended for human consumption Total count of microorganisms at a temperature of (36)°C Plate method (pour plate) PN-EN ISO 6222:2004
28 Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
29 Water Most probable number of Escherichia coli Miniaturized method (MPN) PN-EN ISO 9308-3:2002
30 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
31 Swimming pool water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +AP1:2019-12
32 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
33 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK:2007
34 Swimming pool water Total microorganism count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
Laboratory Division, Infectious Diseases and Infections Testing Section
35 Faeces Presence of Salmonella spp. and Shigella spp. rods Culture method with biochemical and serological confirmation OL/B/PB-01 wydanie 8 z dnia 10.01.2022 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
36 Faeces Presence of Salmonella Enteritidis rods Culture method with biochemical and serological confirmation OL/B/PB-01 wydanie 8 z dnia 10.01.2022 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
37 Faeces Presence of Escherichia coli rods Culture method with biochemical confirmation OL/B/PB-04 wydanie 4 z dnia 02.01.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
38 Faeces Obecność i identyfikacja pałeczek Yersinia sp. Culture method with biochemical confirmation OL/B/PB-06 wydanie 4 z dnia 02.01.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
39 Biological indicators for monitoring sterilisation effectiveness (Sporal A, Sporal S) Presence of indicator microorganisms Geobacillus stearothermophilus Culture method OL/B/PB-02 wydanie 5 z dnia 10.01.2022 r. W oparciu o instrukcje producenta testów
40 Biological indicators for monitoring sterilisation effectiveness (Sporal A, Sporal S) Presence of indicator microorganisms Bacillus subtilis Culture method OL/B/PB-02 wydanie 5 z dnia 10.01.2022 r. W oparciu o instrukcje producenta testów

Reference standards (24)

Metodyka PZH ZHK:2007
OL/B/PB-01 wydanie 8 z dnia 10.01.2022 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
OL/B/PB-02 wydanie 5 z dnia 10.01.2022 r. W oparciu o instrukcje producenta testów
OL/B/PB-04 wydanie 4 z dnia 02.01.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
OL/B/PB-06 wydanie 4 z dnia 02.01.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” pod redakcją Marka Jagielskiego Warszawa 2010
OL/KŚ/PB-03 wyd. 5 z dn. 09.01.2025 r.
OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.
PN-82/C-04576.08
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +AP1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-3:2002
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 9297:1994