🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL
Water & wastewaterEnvironmentMicrobiologyConstruction
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 491 (Leżajsk, Poland). Its accreditation scope covers 26 test methods in the following areas: Water & wastewater, Environment, Microbiology, Construction. Test objects include: Water, Workplace environment - air, Workplace environment - noise, Workplace environment – indoor electric lighting. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Direct measurement method.
At a glance
- Accreditation number: PCA AB 491
- Methods in scope: 26
- Types of test objects: 5
- Techniques used: 12
- City: Leżajsk, Poland
- Accreditation number
- AB 491
- Accreditation body
- PCA
- Address
- W LEŻAJSKU, ul. Mickiewicza 71, 37-300 Leżajsk
- City
- Leżajsk, Poland
What this laboratory tests (5)
- Water — 15 methods
- Workplace environment - air — 6 methods
- Workplace environment - noise — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
- Faeces — 1 method
Analytical techniques used (12)
- Spectrophotometric method — 5 methods
- Membrane filtration method — 4 methods
- Direct measurement method — 2 methods
- Gravimetric method — 2 methods
- Plate method (pour plate) — 2 methods
- Conductometric method — 1 method
- Culture method supplemented with biochemical and serological tests — 1 method
- Electrochemical method — 1 method
- Nephelometric method — 1 method
- Personal dosimetry method — 1 method
- Potentiometric method — 1 method
- Visual method — 1 method
Laboratory sections (3)
- LABORATORY DIVISION; Municipal Hygiene Laboratory — 15 methods
- LABORATORY DIVISION; Occupational Hygiene Laboratory — 10 methods
- LABORATORY DIVISION; Microbiological Diagnostics Laboratory — 1 method
Laboratory locations
- ODDZIAŁ LABORATORYJNY — ul. Mickiewicza 71, 37-300 Leżajsk
- Pracownia Higieny Pracy — ul. Mickiewicza 71, 37-300 Leżajsk
- Pracownia Diagnostyki Mikrobiologicznej — ul. Mickiewicza 71, 37-300 Leżajsk
- Pracownia Higieny Komunalnej — ul. Mickiewicza 71, 37-300 Leżajsk
- ODDZIAŁ LABORATORYJNY; Pracownia Diagnostyki Mikrobiologicznej —
- ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej —
- ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy —
Accreditation scope — test methods (26)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LABORATORY DIVISION; Occupational Hygiene Laboratory | |||||
| 1 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction metals and their compounds including inhalable fraction respirable fraction organic substances, including: inhalable fraction inorganic substances including respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 2 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 3 | Workplace environment - air | Concentration of harmful dust agents -inhalable fraction: Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Synthetic graphite Kaolin Amorphous and synthetic silica a) diatomaceous earth (diatomite) uncalcined b) amorphous precipitated silica and gel Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide non-fibrous Range (0,20 – 16) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 4 | Workplace environment - air | Concentration of harmful dust agents respirable fraction: Apatites and phosphorites Portland cement Amorphous and synthetic silica a) diatomaceous earth (diatomite) uncalcined b) amorphous precipitated silica and gel Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,20 – 16) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment - air | Gas concentrations carbon monoxide Range (2,32-232) mg/m3 Range (2,0-200) ppm |
Electrochemical method | PB/OL-06 edycja 6 z dnia 2026-01-15 | |
| 6 | Workplace environment - air | Exposure index (calculated) | PB/OL-06 edycja 6 z dnia 2026-01-15 | ||
| 7 | Workplace environment – indoor electric lighting | Illuminance Range (0,5 – 10 000) lx |
Direct measurement method | PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01 | |
| 8 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01 | ||
| 9 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (30 – 135) dB C-weighted peak sound pressure level Range (35 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11 | |
| 10 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11 | ||
| LABORATORY DIVISION; Microbiological Diagnostics Laboratory | |||||
| 11 | Faeces | Presence of rods, Salmonella and Shigella | Culture method supplemented with biochemical and serological tests | PB/OL-05 edycja 7 z dnia 2025-01-17 | na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r. | |
| LABORATORY DIVISION; Municipal Hygiene Laboratory | |||||
| 12 | Water | Colour Range (5 – 70) mg/dm3 Pt |
Visual method | PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D | |
| 13 | Water | Ammonium nitrogen concentration Range (0,10 – 2,0) mg/dm3 |
Spectrophotometric method | PN-C-04576-4:1994 | |
| 14 | Water | Nitrate nitrogen concentration Range (0,050 – 14) mg/dm3 |
Spectrophotometric method | PN-82/C-04576/08 | |
| 15 | Water | Total iron concentration Range (30,0 – 2000) μg/dm3 |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 16 | Water | Manganese concentration Range (0,015 – 2,0) mg/dm3 |
Spectrophotometric method | PN-92/C-04590/03 | |
| 17 | Water | Nitrite nitrogen concentration Range (0,005 – 0,200) mg/m3 |
Spectrophotometric method | PN-EN 26777:1999 | |
| 18 | Water | Electrical conductivity Range (76 – 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 19 | Water | pH Range 4,0 – 10,0 |
Potentiometric method | PN – EN ISO 10523:2012 | |
| 20 | Water | Turbidity Range (0,20 – 5,0) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 21 | Water | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 22 | Water | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 23 | Water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 24 | Water | Escherichia Coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 25 | Water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 26 | Water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
Reference standards (24)
PB/OL-05 edycja 7 z dnia 2025-01-17
PB/OL-06 edycja 6 z dnia 2026-01-15
PN – EN ISO 10523:2012
PN-82/C-04576/08
PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01
PN-92/C-04590/03
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11
PN-ISO 6332:2001+Ap1:2016-06
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r.