{"lab":{"_id":"69ad52a3de79e566650fb26f","accr_number":"AB 491","country":"PL","accr_body":"PCA","address":"W LEŻAJSKU, ul. Mickiewicza 71, 37-300 Leżajsk","categories":["water","environment","microbiology","construction"],"city":"Leżajsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":26,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_491.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w leżajsku, ul. mickiewicza 71, 37-300 leżajsk materials environment other construction electronics pharma metrology microbiology water automotive food","status":"active","updated_at":"2026-03-08T14:51:20.601Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:07:52.690Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20491,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests – working environment (harmful factors – air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe - hałas, oświetlenie)","en":"Test concerning environmental engineering (environmental and climatic) – working environmental (harmful and nuisance factors – noise, lighting)"},{"codes":"K/3; K/28, K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"},{"codes":"N/28, N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"N/33","pl":"Badania właściwości fizycznych - środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"}],"issue":{"no":"29","date":"03.07.2026"},"parse_date":"2026-08-13T08:07:52.690Z","parse_source":"agent-claude-code","map_coord":[50.263058,22.417723],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ LABORATORYJNY","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"Pracownia Higieny Pracy","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"Pracownia Diagnostyki Mikrobiologicznej","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"Pracownia Higieny Komunalnej","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Diagnostyki Mikrobiologicznej","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/9d707a1eb7b7e02e701dcb8f493000b5/AB%20491.pdf","has_en":true,"category_counts":{"water":15,"environment":10,"microbiology":3,"construction":2,"materials":1},"category_scores":{"water":7.26,"environment":3.23,"microbiology":0.29,"construction":0.13,"materials":0.03},"has_zh":true,"lab_locations_zh":[{"name":"ODDZIAŁ LABORATORYJNY","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"Pracownia Higieny Pracy","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"Pracownia Diagnostyki Mikrobiologicznej","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"公共卫生室","address":"ul. Mickiewicza 71, 37-300 Leżajsk","city":"Leżajsk","postal":"37-300"},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Diagnostyki Mikrobiologicznej","address":null,"city":null,"postal":null},{"name":"实验室分部；公共卫生检验室","address":null,"city":null,"postal":null},{"name":"实验室分部；职业卫生实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7b580636ba417e41bc9a","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym:"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne w tym"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne w tym\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including:"},{"name":"inhalable fraction"},{"name":"inorganic substances including"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method LABORATORY DIVISION; Occupational Hygiene Laboratory dust agents inhalable fraction respirable fraction metals and their compounds including inhalable fraction respirable fraction organic substances, including: inhalable fraction inorganic substances including respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"metale i ich związki w tym"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，其中包括："},{"name":"可吸入组分"},{"name":"substancje nieorganiczne w tym"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 实验室分部；职业卫生实验室 粉尘因素 可吸入组分 呼吸性组分 可吸入组分 呼吸性组分 有机物质，其中包括： 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bc9b","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 实验室分部；职业卫生实验室 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bc9c","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia -frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna i mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węgiel magnezu wapnia (dolomit)"},{"name":"Węglik krzemu niewłóknisty"},{"name":"Zakres","range":"(0,20 – 16) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia -frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna i mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nWęgiel magnezu wapnia (dolomit)\nWęglik krzemu niewłóknisty\nZakres (0,20 – 16) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia -frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna i mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nWęgiel magnezu wapnia (dolomit)\nWęglik krzemu niewłóknisty\nZakres (0,20 – 16) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia -frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa stracona i zel\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna i maki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWegiel (kamienny, brunatny)\nWegiel magnezu wapnia (dolomit)\nWeglik krzemu niewloknisty\nZakres (0,20 – 16) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Concentration of harmful dust agents -inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica a) diatomaceous earth (diatomite) uncalcined b) amorphous precipitated silica and gel"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide non-fibrous"},{"name":"Range","range":"(0,20 – 16) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents -inhalable fraction: Gravimetric method LABORATORY DIVISION; Occupational Hygiene Laboratory Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Synthetic graphite Kaolin Amorphous and synthetic silica a) diatomaceous earth (diatomite) uncalcined b) amorphous precipitated silica and gel Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"Krzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动物源与植物源有机粉尘，木粉与面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"煤（烟煤、褐煤）"},{"name":"Węgiel magnezu wapnia (dolomit)"},{"name":"非纤维状碳化硅"},{"name":"范围","range":"(0,20 – 16) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 实验室分部；职业卫生实验室 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 合成石墨 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 动物源与植物源有机粉尘，木粉与面粉除外 炭黑 硫酸钙（VI）（石膏） 煤（烟煤、褐煤） 非纤维状碳化硅 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bc9d","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Krzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,20 – 16) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nKrzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,20 – 16) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nKrzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,20 – 16) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nKrzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa stracona i zel\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,20 – 16) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Concentration of harmful dust agents respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Amorphous and synthetic silica a) diatomaceous earth (diatomite) uncalcined b) amorphous precipitated silica and gel"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,20 – 16) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents respirable fraction: Gravimetric method LABORATORY DIVISION; Occupational Hygiene Laboratory Apatites and phosphorites Portland cement Amorphous and synthetic silica a) diatomaceous earth (diatomite) uncalcined b) amorphous precipitated silica and gel Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"Krzemionka bezpostaciowa i syntetyczna a) ziemia okrzemkowa (diatomit) niekalcynowana b) krzemionka bezpostaciowa strącona i żel"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,20 – 16) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 实验室分部；职业卫生实验室 磷灰石与磷块岩 硅酸盐水泥 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bc9e","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie gazów","parameters":[{"name":"tlenku węgla"},{"name":"Zakres","range":"(2,32-232) mg/m3"},{"name":"Zakres","range":"(2,0-200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\ntlenku węgla\nZakres (2,32-232) mg/m3\nZakres (2,0-200) ppm\nMetoda elektrochemiczna","reference":"PB/OL-06 edycja 6 z dnia 2026-01-15","norm_bases":["PB/OL-06 edycja 6 z dnia 2026-01-15"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie gazów\nZakres:\ntlenku węgla\nZakres (2,32-232) mg/m3\nZakres (2,0-200) ppm\nMetoda elektrochemiczna PB/OL-06 edycja 6 z dnia 2026-01-15 Srodowisko pracy - powietrze Stezenie gazow\nZakres:\ntlenku wegla\nZakres (2,32-232) mg/m3\nZakres (2,0-200) ppm\nMetoda elektrochemiczna PB/OL-06 edycja 6 z dnia 2026-01-15","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Gas concentrations","parameters_en":[{"name":"carbon monoxide"},{"name":"Range","range":"(2,32-232) mg/m3"},{"name":"Range","range":"(2,0-200) ppm"}],"search_en":"Workplace environment - air Gas concentrations Electrochemical method LABORATORY DIVISION; Occupational Hygiene Laboratory carbon monoxide Range Range PB/OL-06 edycja 6 z dnia 2026-01-15","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"一氧化碳"},{"name":"范围","range":"(2,32-232) mg/m3"},{"name":"范围","range":"(2,0-200) ppm"}],"search_zh":"工作场所环境 — 空气 气体浓度 电化学法 实验室分部；职业卫生实验室 一氧化碳 范围 范围 PB/OL-06 edycja 6 z dnia 2026-01-15","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室","methodology_zh":"气体浓度"},{"_id":"6a7d7b580636ba417e41bc9f","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB/OL-06 edycja 6 z dnia 2026-01-15","norm_bases":["PB/OL-06 edycja 6 z dnia 2026-01-15"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PB/OL-06 edycja 6 z dnia 2026-01-15 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PB/OL-06 edycja 6 z dnia 2026-01-15","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PB/OL-06 edycja 6 z dnia 2026-01-15","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 实验室分部；职业卫生实验室 PB/OL-06 edycja 6 z dnia 2026-01-15","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bca0","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 10 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 10 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","norm_bases":["PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 – 10 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 – 10 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 10 000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method LABORATORY DIVISION; Occupational Hygiene Laboratory Range PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 10 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 实验室分部；职业卫生实验室 范围 PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bca1","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","norm_bases":["PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 实验室分部；职业卫生实验室 PN-83/E-04040.03 PB/OL-01 edycja 9 z dnia 2024-02-01","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bca2","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i Strategie 3 – punkt 10 i punkt 11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(30 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(35 – 138) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method LABORATORY DIVISION; Occupational Hygiene Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(30 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 实验室分部；职业卫生实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bca3","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8 godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i Strategie 3 – punkt 10 i punkt 11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: LABORATORY DIVISION; Occupational Hygiene Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 实验室分部；职业卫生实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7b580636ba417e41bca4","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Kał","methodology":"Obecność pałeczek, Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność pałeczek, Salmonella i Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"PB/OL-05 edycja 7 z dnia 2025-01-17 | na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r.","norm_bases":["PB/OL-05 edycja 7 z dnia 2025-01-17","na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Diagnostyki Mikrobiologicznej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność pałeczek, Salmonella i Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi PB/OL-05 edycja 7 z dnia 2025-01-17 | na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r. Kal Obecnosc paleczek, Salmonella i Shigella\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi PB/OL-05 edycja 7 z dnia 2025-01-17 | na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakazen przewodu pokarmowego oraz zatruc” pod redakcja Marka Jagielskiego z 2010 r.","categories":["microbiology"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Microbiological Diagnostics Laboratory","methodology_en":"Presence of rods, Salmonella and Shigella","search_en":"Faeces Presence of rods, Salmonella and Shigella Culture method supplemented with biochemical and serological tests LABORATORY DIVISION; Microbiological Diagnostics Laboratory PB/OL-05 edycja 7 z dnia 2025-01-17 | na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r.","technique_en":"Culture method supplemented with biochemical and serological tests","test_object_en":"Faeces","search_zh":"粪便 培养法，辅以生化与血清学试验 PB/OL-05 edycja 7 z dnia 2025-01-17 | na podstawie wytycznych zawartych w „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń przewodu pokarmowego oraz zatruć” pod redakcją Marka Jagielskiego z 2010 r.","test_object_zh":"粪便","technique_zh":"培养法，辅以生化与血清学试验"},{"_id":"6a7d7b580636ba417e41bca5","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/dm3 Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/dm3 Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 – 70) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D Woda Barwa\nZakres (5 – 70) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/dm3 Pt"}],"search_en":"Water Colour Visual method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","technique_en":"Visual method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/dm3 Pt"}],"search_zh":"水 色度 目视法 实验室分部；公共卫生检验室 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","technique_zh":"目视法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bca6","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 2,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu amonowego\nZakres (0,10 – 2,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda Stezenie azotu amonowego\nZakres (0,10 – 2,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/dm3"}],"search_en":"Water Ammonium nitrogen concentration Spectrophotometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/dm3"}],"search_zh":"水 氨氮浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bca7","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,050 – 14) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,050 – 14) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotanowego\nZakres (0,050 – 14) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda Stezenie azotu azotanowego\nZakres (0,050 – 14) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 14) mg/dm3"}],"search_en":"Water Nitrate nitrogen concentration Spectrophotometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 14) mg/dm3"}],"search_zh":"水 硝态氮浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bca8","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(30,0 – 2000) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (30,0 – 2000) μg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (30,0 – 2000) μg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda Stezenie zelaza ogolnego\nZakres (30,0 – 2000) μg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(30,0 – 2000) μg/dm3"}],"search_en":"Water Total iron concentration Spectrophotometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30,0 – 2000) μg/dm3"}],"search_zh":"水 总铁浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bca9","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,015 – 2,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,015 – 2,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (0,015 – 2,0) mg/dm3\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda Stezenie manganu\nZakres (0,015 – 2,0) mg/dm3\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,015 – 2,0) mg/dm3"}],"search_en":"Water Manganese concentration Spectrophotometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 2,0) mg/dm3"}],"search_zh":"水 锰浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcaa","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,005 – 0,200) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,005 – 0,200) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,005 – 0,200) mg/m3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego\nZakres (0,005 – 0,200) mg/m3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,005 – 0,200) mg/m3"}],"search_en":"Water Nitrite nitrogen concentration Spectrophotometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 0,200) mg/m3"}],"search_zh":"水 亚硝态氮浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcab","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(76 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (76 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (76 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (76 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(76 – 2500) μS/cm"}],"search_en":"Water Electrical conductivity Conductometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(76 – 2500) μS/cm"}],"search_zh":"水 电导率 电导法 实验室分部；公共卫生检验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcac","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN – EN ISO 10523:2012","norm_bases":["PN – EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN – EN ISO 10523:2012 Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN – EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water pH Potentiometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN – EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水 pH 值 电位法 实验室分部；公共卫生检验室 范围 PN – EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcad","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 5,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 5,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,20 – 5,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,20 – 5,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 5,0) NTU"}],"search_en":"Water Turbidity Nephelometric method LABORATORY DIVISION; Municipal Hygiene Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 5,0) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 实验室分部；公共卫生检验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcae","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Total viable count at 36°C","search_en":"Water Total viable count at 36°C Plate method (pour plate) LABORATORY DIVISION; Municipal Hygiene Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","search_zh":"水 36°C 微生物总数 平板法（倾注培养） 实验室分部；公共卫生检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水","methodology_zh":"36°C 微生物总数","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcaf","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water Total viable count at 22°C Plate method (pour plate) LABORATORY DIVISION; Municipal Hygiene Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","methodology_zh":"22°C 微生物总数","search_zh":"水 22°C 微生物总数 平板法（倾注培养） 实验室分部；公共卫生检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcb0","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count Membrane filtration method LABORATORY DIVISION; Municipal Hygiene Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcb1","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Escherichia Coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia Coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Escherichia Coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba Escherichia Coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Escherichia Coli count","search_en":"Water Escherichia Coli count Membrane filtration method LABORATORY DIVISION; Municipal Hygiene Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcb2","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method LABORATORY DIVISION; Municipal Hygiene Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7b580636ba417e41bcb3","lab_id":"69ad52a3de79e566650fb26f","country":"PL","accr_number":"AB 491","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Municipal Hygiene Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water Pseudomonas aeruginosa count Membrane filtration method LABORATORY DIVISION; Municipal Hygiene Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"铜绿假单胞菌计数","search_zh":"水 铜绿假单胞菌计数 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"}],"has_pdf":true}