🇵🇱 SUNDOOR Ławecki sp. k. PL

PCA AB 476 • Chorzów, Poland • 45 methods

EnvironmentElectronics & EMC

SUNDOOR Ławecki sp. k. is a laboratory accredited by PCA under number AB 476 (Chorzów, Poland). Its accreditation scope covers 45 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Rooms in residential, collective residence and public utility build…, Środowisko - radiokomunikacyjnych i radionawigacyjnych (pomiary sze…, Workplace environment – emergency lighting, Environment - electromagnetic field in the vicinity of electric pow…. Most frequently used techniques: Direct measurement method, Direct measurement method; Direct measurement method - 800 MHz – 3…, Direct measurement method - 800 MHz – 3 GHz (calculated).

At a glance

  • Accreditation number: PCA AB 476
  • Methods in scope: 45
  • Types of test objects: 22
  • Techniques used: 5
  • City: Chorzów, Poland
Accreditation number
AB 476
Accreditation body
PCA
Address
SUNDOOR LABORATORIUM BADAWCZE, ul. Kurta Aldera 44, 41-506 Chorzów
City
Chorzów, Poland

What this laboratory tests (22)

Analytical techniques used (5)

Accreditation scope — test methods (45)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − electromagnetic field in the workspace from magnetotherapy equipment Magnetic field strength from 20 Hz to 50 Hz
Range 0,1 μT– 19,5 mT
Direct measurement method (simplified) Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180
2 Workplace environment − electromagnetic field originating from power systems and AC electrical supply installations in the power industry Electric field strength
in the frequency range 45 - 55 Hz Range 100 V/m – 30 kV/m
Direct measurement method Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150
3 Workplace environment − electromagnetic field originating from power systems and AC electrical supply installations in the power industry Magnetic field strength in the frequency range 45 - 55 Hz
Range 0,1 μT– 19,5 mT
Direct measurement method Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150
4 Workplace environment − electromagnetic field originating from transmitting devices of radiotelecommunication systems (base stations of mobile telephony systems, telecommunication and radiocommunication transmitting systems – radio, television, etc.) Electric field strength in the frequency range 0,1 MHz – 90GHz
Range 1 V/m – 1 kV/m 80 MHz – 90 GHz Range 1 V/m – 300 V/m
Direct measurement method Podstawy i Metody Ocen Środowiska Pracy 2017, nr 2 (92) s. 89 - 131
5 Workplace environment − electromagnetic field originating from transmitting devices of radiotelecommunication systems (base stations of mobile telephony systems, telecommunication and radiocommunication transmitting systems – radio, television, etc.) Magnetic field strength
in the frequency range 0,1 MHz – 800 MHz Range 0,01 A/m – 10 A/m
Direct measurement method - in the frequency range: 800 MHz – 90 GHz (calculated) Podstawy i Metody Ocen Środowiska Pracy 2017, nr 2 (92) s. 89 - 131
6 Workplace environment − electromagnetic field from industrial installations and equipment: − resistance welding machines − industrial magnetisers and demagnetisers − dielectric heating equipment − induction heating equipment − industrial furnaces, heaters and microwave dryers Electric field strength in the frequency band 5 Hz – 600 kHz
Range 2 V/m – 50 kV/m 100 kHz – 4 GHz Range 1 V/m – 1000 V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 1 – ZPB01-13/14/15/16/18
7 Workplace environment − electromagnetic field from industrial installations and equipment: − resistance welding machines − industrial magnetisers and demagnetisers − dielectric heating equipment − induction heating equipment − industrial furnaces, heaters and microwave dryers Magnetic field strength in the frequency band :
0 Hz Range 0,1 mT– 1200 mT 5 Hz – 600 kHz Range 0, 1 A/m – 8 kA/m 200 kHz – 10 MHz Range 0,01 A/m – 6 A/m 10 MHz – 1000 MHz Range 0,01 A/m – 10 A/m
Direct measurement method - 800 MHz – 3 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 1 – ZPB01-13/14/15/16/18
8 Workplace environment − electromagnetic field from radiocommunication systems: − handheld radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Electric field strength in the frequency band 100 kHz – 4 GHz
Range 1 V/m – 1000 V/m Magnetic field strength in the frequency band : 10 MHz – 1000 MHz Range 0,01 A/m – 10 A/m
Direct measurement method; Direct measurement method - 800 MHz – 3 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 2 – ZPB01-3
9 Workplace environment − electromagnetic field from equipment used in medical technology: − surgical diathermy units − physiotherapy diathermy units − magnetic resonance scanners Electric field strength in the frequency band 5 Hz – 600 kHz
Range 2 V/m – 50 kV/m 100 kHz – 4 GHz Range 1 V/m – 1000 V/m Magnetic field strength in the frequency band : 0 Hz Range 0,1 mT– 1200 mT 5 Hz – 600 kHz Range 0,1 A/m – 8 kA/m 200 kHz – 10 MHz Range 0,01 A/m – 6 A/m 10 MHz – 1000 MHz Range 0,01 A/m – 10 A/m
Direct measurement method; Direct measurement method - 800 MHz – 3 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 3 – ZPB01-8 Załącznik 4 – ZPB01-9 Załącznik 5 – ZPB01-11
10 Environment - electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: in the frequency range 50 Hz
Range (0,1 – 30 ) kV/m
Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17.02. 2020 r. (t.j Dz. U. 2022 poz. 2630)
11 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: in the frequency range 50 Hz
Range (0,1 – 19 500)μΤ Magnetic field strength: in the frequency range 50 Hz Range 0,08 A/m – 15 kA/m (calculated)
Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17.02. 2020 r. (t.j Dz. U. 2022 poz. 2630)
12 Środowisko - radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Electric field strength in the frequency band: 10 MHz – 4 GHz
Range 0,8V/m – 1 kV/m 80 MHz – 90 GHz Range 0,8V/m – 300 V/m
Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17.02. 2020 r. (t.j Dz. U. 2022 poz. 2630)
13 Środowisko - radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Magnetic field strength in the frequency range: 10 MHz – 1 GHz
Range (0,01 – 12) A/m
Direct measurement method Załącznik do Rozporządzenie Ministra Klimatu z dnia 17.02. 2020 r. (t.j Dz. U. 2022 poz. 2630)
14 Środowisko - radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Magnetic field strength: in the frequency range (10 MHz – 90 GHz) (calculated) Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (t.j Dz. U. 2022 poz. 2630)
15 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level
Range (25 – 135) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F
16 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F
17 General environment – noise from roads, railway and tramway lines A-weighted equivalent sound level A-weighted sound exposure level
Range (25 – 135) dB
Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem pkt. H
18 General environment – noise from roads, railway and tramway lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem pkt. H
19 General environment – noise from overhead power lines A-weighted equivalent sound pressure level
Range (25 – 135) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F | PN-N 01339:2000
20 General environment – noise from overhead power lines Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F | PN-N 01339:2000
21 Machinery and equipment – noise Sound pressure level
weighted with the characteristic frequency weighting A Range (25 – 135) dB
Direct measurement method PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
22 Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
23 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (20 – 135) dB
Direct measurement method PN-87/B-02156
24 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156
25 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (20 – 135) dB
Direct measurement method PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010
26 Rooms in residential, collective residence and public utility buildings – noise Reference equivalent A sound level from building service equipment LAeq,nT, Reference maximum A sound level from building service equipment LAmaxnT (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010
27 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (25 – 135) dB C-weighted peak sound pressure level Range (40 – 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 – punkty 10 i 11
28 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 – punkty 10 i 11
29 Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (47 – 150) dB
Direct measurement method PN-Z-01339:2020-12
30 Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-Z-01339:2020-12
31 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,563 - 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
32 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
33 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,032 – 35,48) m/s2
Direct measurement method PN-EN 14253+A1:2011
34 Workplace environment – whole-body vibration Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), (calculated) PN-EN 14253+A1:2011
35 Workplace environment – indoor electric lighting Illuminance
Range (0,5 – 10000) lx
Direct measurement method PN-83 E-04040.03
36 Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-83 E-04040.03
37 Workplace environment – emergency lighting Illuminance
Range (0,5 - 3000) lx
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem p.4.2.5 – 3 .2.7, 4.3.3 – 4.3.7, 4.4.3, 4.4.5 – 4.4.7, 5
38 Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem p.4.2.5 – 3 .2.7, 4.3.3 – 4.3.7, 4.4.3, 4.4.5 – 4.4.7, 5
39 Workplace environment – emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem p.4.2.5 – 3 .2.7, 4.3.3 – 4.3.7, 4.4.3, 4.4.5 – 4.4.7, 5
40 Workplace environment – cold microclimate Air temperature
Range (-30 – 20) °C Black globe temperature Range (-30 – 20) °C Air humidity Range (25 – 75) % Air velocity Range (0,2 – 5) m/s
Direct measurement method PN-EN ISO 11079:2008
41 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
42 Workplace environment – moderate microclimate Air temperature
Range (-30 – 40) °C Black globe temperature Range (-30 – 40) °C Air humidity Range (25 – 75) % Air velocity Range (0,2 – 5) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
43 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
44 Workplace environment – hot microclimate Air temperature
Range (15 – 40) °C Natural wet bulb temperature Range (10 – 40) °C Black globe temperature Range (15 – 40) °C
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap1:2019-07
45 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap1:2019-07

Reference standards (30)

PN-83 E-04040.03
PN-87/B-02156
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem p.4.2.5 – 3 .2.7, 4.3.3 – 4.3.7, 4.4.3, 4.4.5 – 4.4.7, 5
PN-EN ISO 10052:2007
PN-EN ISO 10052:2007/A1:2010
PN-EN ISO 11079:2008
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap1:2019-07
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategie 2 i 3 – punkty 10 i 11
PN-N 01339:2000
PN-N-01307:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 1 – ZPB01-13/14/15/16/18
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 2 – ZPB01-3
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PB-01, wyd. 5 z 7.11.24, Załącznik 3 – ZPB01-8 Załącznik 4 – ZPB01-9 Załącznik 5 – ZPB01-11
PN-Z-01339:2020-12
Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180
Podstawy i Metody Ocen Środowiska Pracy 2016. Nr 4 (90) s. 91-150
Podstawy i Metody Ocen Środowiska Pracy 2017, nr 2 (92) s. 89 - 131
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (t.j Dz. U. 2022 poz. 2630)
Załącznik do Rozporządzenie Ministra Klimatu z dnia 17.02. 2020 r. (t.j Dz. U. 2022 poz. 2630)
Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem pkt. H
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F