🇵🇱 INSTYTUT CHEMII I TECHNIKI JĄDROWEJ PL

PCA AB 461 • Warszawa, Poland • 13 methods

Pharma & cosmeticsMaterials & polymersWater & wastewaterFood & beveragesEnvironment

INSTYTUT CHEMII I TECHNIKI JĄDROWEJ is a laboratory accredited by PCA under number AB 461 (Warszawa, Poland). Its accreditation scope covers 13 test methods in the following areas: Pharma & cosmetics, Materials & polymers, Water & wastewater, Food & beverages. Test objects include: Dosimeters in an ionising radiation field, Biological materials, chemical products, cosmetics, composites, wat…, High-energy electron radiation sources, Radioactive gamma sources. Most frequently used techniques: EPR spectroscopy method, Calorimetric method, EPR spectroscopy method – alanine dosimeter.

At a glance

  • Accreditation number: PCA AB 461
  • Methods in scope: 13
  • Types of test objects: 4
  • Techniques used: 7
  • City: Warszawa, Poland
Accreditation number
AB 461
Accreditation body
PCA
Address
ZAKŁAD NAUKOWY – CENTRUM BADAŃ I TECHNOLOGII RADIACYJNYCH, LABORATORIUM POMIARÓW DAWEK TECHNOLOGICZNYCH, ul. Dorodna 16
City
Warszawa, Poland

What this laboratory tests (4)

Analytical techniques used (7)

Certificate information

Issue date
13.02.2026
Issue no.
20

Accreditation scope — test methods (13)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Radioactive gamma sources Absorbed dose of 60Co gamma radiation
Range (20 - 400) Gy
Spectrophotometric method UV Vis - Fricke dosimeter ASTM 51026-23 ɛ1
2 Radioactive gamma sources Absorbed dose of 60Co gamma radiation
Range (10 - 80) kGy
Spectrophotometric method UV Vis - CTA dosimeter ASTM 51650-21 ɛ1
3 Radioactive gamma sources Absorbed dose of 60Co gamma radiation
Range (0,05 - 100) kGy
EPR spectroscopy method – alanine dosimeter ASTM 51607-22 ɛ1
4 High-energy electron radiation sources Absorbed dose of high-energy electron radiation with an energy of 10 MeV
Range (3 - 40) kGy
Calorimetric method ASTM 51631-20 ɛ1
5 High-energy electron radiation sources Absorbed dose of high-energy electron radiation with an energy of 10 MeV
Range (15 - 40) kGy
Spectrophotometric method UV Vis - CTA dosimeter ASTM 51650-21 ɛ1
6 High-energy electron radiation sources Absorbed dose of high-energy electron radiation up to an energy of 10 MeV
Range (0,05 - 100) kGy
EPR spectroscopy method – alanine dosimeter ASTM 51607-22 ɛ1
7 Dosimeters in an ionising radiation field Absorbed dose of 60Co gamma radiation
Range 20 Gy - 80 kGy
Spectrophotometric method UV Vis ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1
8 Dosimeters in an ionising radiation field Absorbed dose of 60Co gamma radiation
Range (0,05 – 100) kGy
EPR spectroscopy method ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1
9 Dosimeters in an ionising radiation field Absorbed dose
high-energy electron radiation with an energy of 10 MeV Range (3 - 40) kGy
Spectrophotometric method UV Vis ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1
10 Dosimeters in an ionising radiation field Absorbed dose
high-energy electron radiation up to an energy of 10 MeV Range (0,05 - 100) kGy
EPR spectroscopy method ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1
11 Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood Dose of 60Co gamma radiation Calculation method ASTM 51261-13(2020) ɛ1
12 Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood Dose of high-energy electron radiation with an energy of 10 MeV
Range (3 - 40) kGy
Calorimetric method ASTM 51261-13(2020) ɛ1
13 Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood Dose of high-energy electron radiation up to an energy of 10 MeV
Range (0,05 - 100) kGy
EPR spectroscopy method ASTM 51261-13(2020) ɛ1

Reference standards (6)

ASTM 51026-23 ɛ1
ASTM 51261-13(2020) ɛ1
ASTM 51607-22 ɛ1
ASTM 51631-20 ɛ1
ASTM 51650-21 ɛ1
ASTM 52628-20 ɛ1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20461