INSTYTUT CHEMII I TECHNIKI JĄDROWEJ is a laboratory accredited by PCA under number AB 461 (Warszawa, Poland). Its accreditation scope covers 13 test methods in the following areas: Environment, Materials & polymers, Water & wastewater, Food & beverages. Test objects include: Dosimeters in an ionising radiation field, Biological materials, chemical products, cosmetics, composites, wat…, High-energy electron radiation sources, Radioactive gamma sources. Most frequently used techniques: EPR spectroscopy method, Calorimetric method, EPR spectroscopy method – alanine dosimeter.
At a glance
- Accreditation number: PCA AB 461
- Methods in scope: 13
- Types of test objects: 4
- Techniques used: 7
- City: Warszawa, Poland
- Accreditation number
- AB 461
- Accreditation body
- PCA
- Address
- ZAKŁAD NAUKOWY – CENTRUM BADAŃ I TECHNOLOGII RADIACYJNYCH, LABORATORIUM POMIARÓW DAWEK TECHNOLOGICZNYCH, ul. Dorodna 16
- City
- Warszawa, Poland
What this laboratory tests (4)
- Dosimeters in an ionising radiation field — 4 methods
- Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood — 3 methods
- High-energy electron radiation sources — 3 methods
- Radioactive gamma sources — 3 methods
Analytical techniques used (7)
- EPR spectroscopy method — 3 methods
- Calorimetric method — 2 methods
- EPR spectroscopy method – alanine dosimeter — 2 methods
- Spectrophotometric method UV Vis — 2 methods
- Spectrophotometric method UV Vis - CTA dosimeter — 2 methods
- Calculation method — 1 method
- Spectrophotometric method UV Vis - Fricke dosimeter — 1 method
Accreditation scope — test methods (13)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Radioactive gamma sources | Absorbed dose of 60Co gamma radiation Range (20 - 400) Gy |
Spectrophotometric method UV Vis - Fricke dosimeter | ASTM 51026-23 ɛ1 | |
| 2 | Radioactive gamma sources | Absorbed dose of 60Co gamma radiation Range (10 - 80) kGy |
Spectrophotometric method UV Vis - CTA dosimeter | ASTM 51650-21 ɛ1 | |
| 3 | Radioactive gamma sources | Absorbed dose of 60Co gamma radiation Range (0,05 - 100) kGy |
EPR spectroscopy method – alanine dosimeter | ASTM 51607-22 ɛ1 | |
| 4 | High-energy electron radiation sources | Absorbed dose of high-energy electron radiation with an energy of 10 MeV Range (3 - 40) kGy |
Calorimetric method | ASTM 51631-20 ɛ1 | |
| 5 | High-energy electron radiation sources | Absorbed dose of high-energy electron radiation with an energy of 10 MeV Range (15 - 40) kGy |
Spectrophotometric method UV Vis - CTA dosimeter | ASTM 51650-21 ɛ1 | |
| 6 | High-energy electron radiation sources | Absorbed dose of high-energy electron radiation up to an energy of 10 MeV Range (0,05 - 100) kGy |
EPR spectroscopy method – alanine dosimeter | ASTM 51607-22 ɛ1 | |
| 7 | Dosimeters in an ionising radiation field | Absorbed dose of 60Co gamma radiation Range 20 Gy - 80 kGy |
Spectrophotometric method UV Vis | ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 | |
| 8 | Dosimeters in an ionising radiation field | Absorbed dose of 60Co gamma radiation Range (0,05 – 100) kGy |
EPR spectroscopy method | ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 | |
| 9 | Dosimeters in an ionising radiation field | Absorbed dose high-energy electron radiation with an energy of 10 MeV Range (3 - 40) kGy |
Spectrophotometric method UV Vis | ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 | |
| 10 | Dosimeters in an ionising radiation field | Absorbed dose high-energy electron radiation up to an energy of 10 MeV Range (0,05 - 100) kGy |
EPR spectroscopy method | ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 | |
| 11 | Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood | Dose of 60Co gamma radiation | Calculation method | ASTM 51261-13(2020) ɛ1 | |
| 12 | Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood | Dose of high-energy electron radiation with an energy of 10 MeV Range (3 - 40) kGy |
Calorimetric method | ASTM 51261-13(2020) ɛ1 | |
| 13 | Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood | Dose of high-energy electron radiation up to an energy of 10 MeV Range (0,05 - 100) kGy |
EPR spectroscopy method | ASTM 51261-13(2020) ɛ1 | |
Reference standards (6)
ASTM 51026-23 ɛ1
ASTM 51261-13(2020) ɛ1
ASTM 51607-22 ɛ1
ASTM 51631-20 ɛ1
ASTM 51650-21 ɛ1
ASTM 52628-20 ɛ1