{"lab":{"_id":"69ad52a3de79e566650fb24d","accr_number":"AB 461","country":"PL","accr_body":"PCA","address":"ZAKŁAD NAUKOWY – CENTRUM BADAŃ I TECHNOLOGII RADIACYJNYCH, LABORATORIUM POMIARÓW DAWEK TECHNOLOGICZNYCH, ul. Dorodna 16","categories":["pharma","materials","water","food","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":13,"name":"INSTYTUT CHEMII I TECHNIKI JĄDROWEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_461.pdf"],"scope_summary":"","search_text":"instytut chemii i techniki jądrowej zakład naukowy – centrum badań i technologii radiacyjnych, laboratorium pomiarów dawek technologicznych, ul. dorodna 16 other electronics pharma materials water environment food","status":"active","updated_at":"2026-03-08T14:51:18.356Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:18.356Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20461,podmiot.html","fields_of_testing":[{"codes":"O/3, O/4, O/12, O/17, O/18, O/20, O/21, O/22, O/23, O/27, O/28, O/30, O/31, O/32, O/42","pl":"Badania promieniowania – w tym nuklearne materiałów biologicznych, wyrobów chemicznych, kosmetyków, kompozytów, wody, gleby, osadów i ścieków, szkła i ceramiki, wyrobów innych – dawkomierzy, papieru, materiałów opakowaniowych, wyrobów farmaceutycznych, wyrobów z tworzyw sztucznych, żywności, tekstyliów, drewna","en":"Tests of radiation – including nuclear radiation in the biological items, chemical products, cosmetics, composite materials, water, soil, sediments and sewage, lubricants, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood"}],"issue":{"no":"20","date":"13.02.2026"},"parse_date":"2026-07-20T07:09:39.382Z","parse_source":"script-pdfplumber","map_coord":[52.301186,20.980767],"map_geo":"nominatim-street","has_zh":true,"has_en":true,"category_counts":{"other":10,"pharma":3,"materials":3,"water":3,"food":3,"environment":3},"category_scores":{"other":4,"pharma":0.36,"materials":0.36,"water":0.36,"food":0.36,"environment":0.36}},"methods":[{"_id":"6a5dc9b3f1c10c8ce825c1ba","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Źródła gamma promieniotwórcze","test_object_en":"Radioactive gamma sources","methodology":"Dawka pochłonięta promieniowania gamma 60Co","methodology_en":"Absorbed dose of 60Co gamma radiation","parameters":[{"name":"Zakres","range":"(20 - 400) Gy"}],"parameters_en":[{"name":"Range","range":"(20 - 400) Gy"}],"technique":"Metoda spektrofotometryczna UV Vis - dawkomierz Fricke’go","techniques":["Metoda spektrofotometryczna UV Vis - dawkomierz Fricke’go"],"technique_en":"Spectrophotometric method UV Vis - Fricke dosimeter","computed":[],"computed_en":[],"activity":"Dawka pochłonięta promieniowania gamma 60Co\nZakres (20 - 400) Gy\nMetoda spektrofotometryczna UV Vis - dawkomierz Fricke’go","reference":"ASTM 51026-23 ɛ1","norm_bases":["ASTM 51026-23 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła gamma promieniotwórcze Dawka pochłonięta promieniowania gamma 60Co\nZakres (20 - 400) Gy\nMetoda spektrofotometryczna UV Vis - dawkomierz Fricke’go ASTM 51026-23 ɛ1 Zrodla gamma promieniotworcze Dawka pochlonieta promieniowania gamma 60Co\nZakres (20 - 400) Gy\nMetoda spektrofotometryczna UV Vis - dawkomierz Fricke’go ASTM 51026-23 ɛ1","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"60Co 伽马辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(20 - 400) Gy"}],"search_zh":"放射性伽马源 60Co 伽马辐射吸收剂量 紫外-可见分光光度法 - Fricke 剂量计 范围 ASTM 51026-23 ɛ1","technique_zh":"紫外-可见分光光度法 - Fricke 剂量计","test_object_zh":"放射性伽马源","search_en":"Radioactive gamma sources Absorbed dose of 60Co gamma radiation Spectrophotometric method UV Vis - Fricke dosimeter Range ASTM 51026-23 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1bb","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Źródła gamma promieniotwórcze","test_object_en":"Radioactive gamma sources","methodology":"Dawka pochłonięta promieniowania gamma 60Co","methodology_en":"Absorbed dose of 60Co gamma radiation","parameters":[{"name":"Zakres","range":"(10 - 80) kGy"}],"parameters_en":[{"name":"Range","range":"(10 - 80) kGy"}],"technique":"Metoda spektrofotometryczna UV Vis - dawkomierz CTA","techniques":["Metoda spektrofotometryczna UV Vis - dawkomierz CTA"],"technique_en":"Spectrophotometric method UV Vis - CTA dosimeter","computed":[],"computed_en":[],"activity":"Dawka pochłonięta promieniowania gamma 60Co\nZakres (10 - 80) kGy\nMetoda spektrofotometryczna UV Vis - dawkomierz CTA","reference":"ASTM 51650-21 ɛ1","norm_bases":["ASTM 51650-21 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła gamma promieniotwórcze Dawka pochłonięta promieniowania gamma 60Co\nZakres (10 - 80) kGy\nMetoda spektrofotometryczna UV Vis - dawkomierz CTA ASTM 51650-21 ɛ1 Zrodla gamma promieniotworcze Dawka pochlonieta promieniowania gamma 60Co\nZakres (10 - 80) kGy\nMetoda spektrofotometryczna UV Vis - dawkomierz CTA ASTM 51650-21 ɛ1","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"60Co 伽马辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(10 - 80) kGy"}],"search_zh":"放射性伽马源 60Co 伽马辐射吸收剂量 紫外-可见分光光度法 - CTA 剂量计 范围 ASTM 51650-21 ɛ1","technique_zh":"紫外-可见分光光度法 - CTA 剂量计","test_object_zh":"放射性伽马源","search_en":"Radioactive gamma sources Absorbed dose of 60Co gamma radiation Spectrophotometric method UV Vis - CTA dosimeter Range ASTM 51650-21 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1bc","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Źródła gamma promieniotwórcze","test_object_en":"Radioactive gamma sources","methodology":"Dawka pochłonięta promieniowania gamma 60Co","methodology_en":"Absorbed dose of 60Co gamma radiation","parameters":[{"name":"Zakres","range":"(0,05 - 100) kGy"}],"parameters_en":[{"name":"Range","range":"(0,05 - 100) kGy"}],"technique":"Metoda spektroskopii EPR – dawkomierz alaninowy","techniques":["Metoda spektroskopii EPR – dawkomierz alaninowy"],"technique_en":"EPR spectroscopy method – alanine dosimeter","computed":[],"computed_en":[],"activity":"Dawka pochłonięta promieniowania gamma 60Co\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR – dawkomierz alaninowy","reference":"ASTM 51607-22 ɛ1","norm_bases":["ASTM 51607-22 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła gamma promieniotwórcze Dawka pochłonięta promieniowania gamma 60Co\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR – dawkomierz alaninowy ASTM 51607-22 ɛ1 Zrodla gamma promieniotworcze Dawka pochlonieta promieniowania gamma 60Co\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR – dawkomierz alaninowy ASTM 51607-22 ɛ1","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"60Co 伽马辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(0,05 - 100) kGy"}],"search_zh":"放射性伽马源 60Co 伽马辐射吸收剂量 电子顺磁共振（EPR）波谱法 – 丙氨酸剂量计 范围 ASTM 51607-22 ɛ1","technique_zh":"电子顺磁共振（EPR）波谱法 – 丙氨酸剂量计","test_object_zh":"放射性伽马源","search_en":"Radioactive gamma sources Absorbed dose of 60Co gamma radiation EPR spectroscopy method – alanine dosimeter Range ASTM 51607-22 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1bd","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Źródła wysokoenergetycznego promieniowania elektronowego","test_object_en":"High-energy electron radiation sources","methodology":"Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV","methodology_en":"Absorbed dose of high-energy electron radiation with an energy of 10 MeV","parameters":[{"name":"Zakres","range":"(3 - 40) kGy"}],"parameters_en":[{"name":"Range","range":"(3 - 40) kGy"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda kalorymetryczna","reference":"ASTM 51631-20 ɛ1","norm_bases":["ASTM 51631-20 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła wysokoenergetycznego promieniowania elektronowego Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda kalorymetryczna ASTM 51631-20 ɛ1 Zrodla wysokoenergetycznego promieniowania elektronowego Dawka pochlonieta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda kalorymetryczna ASTM 51631-20 ɛ1","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"能量为 10 MeV 的高能电子辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(3 - 40) kGy"}],"search_zh":"高能电子辐射源 能量为 10 MeV 的高能电子辐射吸收剂量 量热法 范围 ASTM 51631-20 ɛ1","technique_zh":"量热法","test_object_zh":"高能电子辐射源","search_en":"High-energy electron radiation sources Absorbed dose of high-energy electron radiation with an energy of 10 MeV Calorimetric method Range ASTM 51631-20 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1be","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Źródła wysokoenergetycznego promieniowania elektronowego","test_object_en":"High-energy electron radiation sources","methodology":"Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV","methodology_en":"Absorbed dose of high-energy electron radiation with an energy of 10 MeV","parameters":[{"name":"Zakres","range":"(15 - 40) kGy"}],"parameters_en":[{"name":"Range","range":"(15 - 40) kGy"}],"technique":"Metoda spektrofotometryczna UV Vis - dawkomierz CTA","techniques":["Metoda spektrofotometryczna UV Vis - dawkomierz CTA"],"technique_en":"Spectrophotometric method UV Vis - CTA dosimeter","computed":[],"computed_en":[],"activity":"Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (15 - 40) kGy\nMetoda spektrofotometryczna UV Vis - dawkomierz CTA","reference":"ASTM 51650-21 ɛ1","norm_bases":["ASTM 51650-21 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła wysokoenergetycznego promieniowania elektronowego Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (15 - 40) kGy\nMetoda spektrofotometryczna UV Vis - dawkomierz CTA ASTM 51650-21 ɛ1 Zrodla wysokoenergetycznego promieniowania elektronowego Dawka pochlonieta wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (15 - 40) kGy\nMetoda spektrofotometryczna UV Vis - dawkomierz CTA ASTM 51650-21 ɛ1","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"能量为 10 MeV 的高能电子辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(15 - 40) kGy"}],"search_zh":"高能电子辐射源 能量为 10 MeV 的高能电子辐射吸收剂量 紫外-可见分光光度法 - CTA 剂量计 范围 ASTM 51650-21 ɛ1","technique_zh":"紫外-可见分光光度法 - CTA 剂量计","test_object_zh":"高能电子辐射源","search_en":"High-energy electron radiation sources Absorbed dose of high-energy electron radiation with an energy of 10 MeV Spectrophotometric method UV Vis - CTA dosimeter Range ASTM 51650-21 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1bf","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Źródła wysokoenergetycznego promieniowania elektronowego","test_object_en":"High-energy electron radiation sources","methodology":"Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego do energii 10 MeV","methodology_en":"Absorbed dose of high-energy electron radiation up to an energy of 10 MeV","parameters":[{"name":"Zakres","range":"(0,05 - 100) kGy"}],"parameters_en":[{"name":"Range","range":"(0,05 - 100) kGy"}],"technique":"Metoda spektroskopii EPR – dawkomierz alaninowy","techniques":["Metoda spektroskopii EPR – dawkomierz alaninowy"],"technique_en":"EPR spectroscopy method – alanine dosimeter","computed":[],"computed_en":[],"activity":"Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR – dawkomierz alaninowy","reference":"ASTM 51607-22 ɛ1","norm_bases":["ASTM 51607-22 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Źródła wysokoenergetycznego promieniowania elektronowego Dawka pochłonięta wysokoenergetycznego promieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR – dawkomierz alaninowy ASTM 51607-22 ɛ1 Zrodla wysokoenergetycznego promieniowania elektronowego Dawka pochlonieta wysokoenergetycznego promieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR – dawkomierz alaninowy ASTM 51607-22 ɛ1","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"能量不超过 10 MeV 的高能电子辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(0,05 - 100) kGy"}],"search_zh":"高能电子辐射源 能量不超过 10 MeV 的高能电子辐射吸收剂量 电子顺磁共振（EPR）波谱法 – 丙氨酸剂量计 范围 ASTM 51607-22 ɛ1","technique_zh":"电子顺磁共振（EPR）波谱法 – 丙氨酸剂量计","test_object_zh":"高能电子辐射源","search_en":"High-energy electron radiation sources Absorbed dose of high-energy electron radiation up to an energy of 10 MeV EPR spectroscopy method – alanine dosimeter Range ASTM 51607-22 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c0","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Dawka pochłonięta promieniowania gamma 60Co","methodology_en":"Absorbed dose of 60Co gamma radiation","parameters":[{"name":"Zakres","range":"20 Gy - 80 kGy"}],"parameters_en":[{"name":"Range","range":"20 Gy - 80 kGy"}],"technique":"Metoda spektrofotometryczna UV Vis","techniques":["Metoda spektrofotometryczna UV Vis"],"technique_en":"Spectrophotometric method UV Vis","computed":[],"computed_en":[],"activity":"Dawka pochłonięta promieniowania gamma 60Co\nZakres 20 Gy - 80 kGy\nMetoda spektrofotometryczna UV Vis","reference":"ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1","ASTM 52628-20 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Dawka pochłonięta promieniowania gamma 60Co\nZakres 20 Gy - 80 kGy\nMetoda spektrofotometryczna UV Vis ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 Dawkomierze w polu promieniowania jonizujacego Dawka pochlonieta promieniowania gamma 60Co\nZakres 20 Gy - 80 kGy\nMetoda spektrofotometryczna UV Vis ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"60Co 伽马辐射吸收剂量","parameters_zh":[{"name":"范围","range":"20 Gy - 80 kGy"}],"search_zh":"电离辐射场中的剂量计 60Co 伽马辐射吸收剂量 紫外-可见分光光度法 范围 ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","technique_zh":"紫外-可见分光光度法","test_object_zh":"电离辐射场中的剂量计","search_en":"Dosimeters in an ionising radiation field Absorbed dose of 60Co gamma radiation Spectrophotometric method UV Vis Range ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c1","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Dawka pochłonięta promieniowania gamma 60Co","methodology_en":"Absorbed dose of 60Co gamma radiation","parameters":[{"name":"Zakres","range":"(0,05 – 100) kGy"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) kGy"}],"technique":"Metoda spektroskopii EPR","techniques":["Metoda spektroskopii EPR"],"technique_en":"EPR spectroscopy method","computed":[],"computed_en":[],"activity":"Dawka pochłonięta promieniowania gamma 60Co\nZakres (0,05 – 100) kGy\nMetoda spektroskopii EPR","reference":"ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1","ASTM 52628-20 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Dawka pochłonięta promieniowania gamma 60Co\nZakres (0,05 – 100) kGy\nMetoda spektroskopii EPR ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 Dawkomierze w polu promieniowania jonizujacego Dawka pochlonieta promieniowania gamma 60Co\nZakres (0,05 – 100) kGy\nMetoda spektroskopii EPR ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"60Co 伽马辐射吸收剂量","parameters_zh":[{"name":"范围","range":"(0,05 – 100) kGy"}],"search_zh":"电离辐射场中的剂量计 60Co 伽马辐射吸收剂量 电子顺磁共振（EPR）波谱法 范围 ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","technique_zh":"电子顺磁共振（EPR）波谱法","test_object_zh":"电离辐射场中的剂量计","search_en":"Dosimeters in an ionising radiation field Absorbed dose of 60Co gamma radiation EPR spectroscopy method Range ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c2","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Dawka pochłonięta","methodology_en":"Absorbed dose","parameters":[{"name":"wysokoenergetycznego"},{"name":"promieniowania elektronowego o energii 10 MeV"},{"name":"Zakres","range":"(3 - 40) kGy"}],"parameters_en":[{"name":"high-energy"},{"name":"electron radiation with an energy of 10 MeV"},{"name":"Range","range":"(3 - 40) kGy"}],"technique":"Metoda spektrofotometryczna UV Vis","techniques":["Metoda spektrofotometryczna UV Vis"],"technique_en":"Spectrophotometric method UV Vis","computed":[],"computed_en":[],"activity":"Dawka pochłonięta\nZakres:\nwysokoenergetycznego\npromieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda spektrofotometryczna UV Vis","reference":"ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1","ASTM 52628-20 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Dawka pochłonięta\nZakres:\nwysokoenergetycznego\npromieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda spektrofotometryczna UV Vis ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 Dawkomierze w polu promieniowania jonizujacego Dawka pochlonieta\nZakres:\nwysokoenergetycznego\npromieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda spektrofotometryczna UV Vis ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"吸收剂量","parameters_zh":[{"name":"高能"},{"name":"能量为 10 MeV 的电子辐射"},{"name":"范围","range":"(3 - 40) kGy"}],"search_zh":"电离辐射场中的剂量计 吸收剂量 紫外-可见分光光度法 高能 能量为 10 MeV 的电子辐射 范围 ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","technique_zh":"紫外-可见分光光度法","test_object_zh":"电离辐射场中的剂量计","search_en":"Dosimeters in an ionising radiation field Absorbed dose Spectrophotometric method UV Vis high-energy electron radiation with an energy of 10 MeV Range ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c3","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Dawka pochłonięta","methodology_en":"Absorbed dose","parameters":[{"name":"wysokoenergetycznego"},{"name":"promieniowania elektronowego do energii 10 MeV"},{"name":"Zakres","range":"(0,05 - 100) kGy"}],"parameters_en":[{"name":"high-energy"},{"name":"electron radiation up to an energy of 10 MeV"},{"name":"Range","range":"(0,05 - 100) kGy"}],"technique":"Metoda spektroskopii EPR","techniques":["Metoda spektroskopii EPR"],"technique_en":"EPR spectroscopy method","computed":[],"computed_en":[],"activity":"Dawka pochłonięta\nZakres:\nwysokoenergetycznego\npromieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR","reference":"ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1","ASTM 52628-20 ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Dawka pochłonięta\nZakres:\nwysokoenergetycznego\npromieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1 Dawkomierze w polu promieniowania jonizujacego Dawka pochlonieta\nZakres:\nwysokoenergetycznego\npromieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"吸收剂量","parameters_zh":[{"name":"高能"},{"name":"能量不超过 10 MeV 的电子辐射"},{"name":"范围","range":"(0,05 - 100) kGy"}],"search_zh":"电离辐射场中的剂量计 吸收剂量 电子顺磁共振（EPR）波谱法 高能 能量不超过 10 MeV 的电子辐射 范围 ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1","technique_zh":"电子顺磁共振（EPR）波谱法","test_object_zh":"电离辐射场中的剂量计","search_en":"Dosimeters in an ionising radiation field Absorbed dose EPR spectroscopy method high-energy electron radiation up to an energy of 10 MeV Range ASTM 51261-13(2020) ɛ1 | ASTM 52628-20 ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c4","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Materiały biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i ścieki, szkło i ceramika, wyroby inne – dawkomierze, papier, materiały opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, żywność, tekstylia, drewno","test_object_en":"Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood","methodology":"Dawka promieniowania gamma 60Co","methodology_en":"Dose of 60Co gamma radiation","parameters":[],"parameters_en":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"technique_en":"Calculation method","computed":[],"computed_en":[],"activity":"Dawka promieniowania gamma 60Co\nMetoda obliczeniowa","reference":"ASTM 51261-13(2020) ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i ścieki, szkło i ceramika, wyroby inne – dawkomierze, papier, materiały opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, żywność, tekstylia, drewno Dawka promieniowania gamma 60Co\nMetoda obliczeniowa ASTM 51261-13(2020) ɛ1 Materialy biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i scieki, szklo i ceramika, wyroby inne – dawkomierze, papier, materialy opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, zywnosc, tekstylia, drewno Dawka promieniowania gamma 60Co\nMetoda obliczeniowa ASTM 51261-13(2020) ɛ1","categories":["water","materials","pharma","food","environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"60Co 伽马辐射剂量","search_zh":"生物材料、化学制品、化妆品、复合材料、水、土壤、污泥与污水、玻璃与陶瓷、其他制品 – 剂量计、纸张、包装材料、药品、塑料制品、食品、纺织品、木材 60Co 伽马辐射剂量 计算法 ASTM 51261-13(2020) ɛ1","technique_zh":"计算法","test_object_zh":"生物材料、化学制品、化妆品、复合材料、水、土壤、污泥与污水、玻璃与陶瓷、其他制品 – 剂量计、纸张、包装材料、药品、塑料制品、食品、纺织品、木材","search_en":"Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood Dose of 60Co gamma radiation Calculation method ASTM 51261-13(2020) ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c5","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Materiały biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i ścieki, szkło i ceramika, wyroby inne – dawkomierze, papier, materiały opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, żywność, tekstylia, drewno","test_object_en":"Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood","methodology":"Dawka wysokoenergetycznego promieniowania elektronowego o energii 10 MeV","methodology_en":"Dose of high-energy electron radiation with an energy of 10 MeV","parameters":[{"name":"Zakres","range":"(3 - 40) kGy"}],"parameters_en":[{"name":"Range","range":"(3 - 40) kGy"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Dawka wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda kalorymetryczna","reference":"ASTM 51261-13(2020) ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i ścieki, szkło i ceramika, wyroby inne – dawkomierze, papier, materiały opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, żywność, tekstylia, drewno Dawka wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda kalorymetryczna ASTM 51261-13(2020) ɛ1 Materialy biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i scieki, szklo i ceramika, wyroby inne – dawkomierze, papier, materialy opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, zywnosc, tekstylia, drewno Dawka wysokoenergetycznego promieniowania elektronowego o energii 10 MeV\nZakres (3 - 40) kGy\nMetoda kalorymetryczna ASTM 51261-13(2020) ɛ1","categories":["water","materials","pharma","food","environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"能量为 10 MeV 的高能电子辐射剂量","parameters_zh":[{"name":"范围","range":"(3 - 40) kGy"}],"search_zh":"生物材料、化学制品、化妆品、复合材料、水、土壤、污泥与污水、玻璃与陶瓷、其他制品 – 剂量计、纸张、包装材料、药品、塑料制品、食品、纺织品、木材 能量为 10 MeV 的高能电子辐射剂量 量热法 范围 ASTM 51261-13(2020) ɛ1","technique_zh":"量热法","test_object_zh":"生物材料、化学制品、化妆品、复合材料、水、土壤、污泥与污水、玻璃与陶瓷、其他制品 – 剂量计、纸张、包装材料、药品、塑料制品、食品、纺织品、木材","search_en":"Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood Dose of high-energy electron radiation with an energy of 10 MeV Calorimetric method Range ASTM 51261-13(2020) ɛ1"},{"_id":"6a5dc9b3f1c10c8ce825c1c6","lab_id":"69ad52a3de79e566650fb24d","country":"PL","accr_number":"AB 461","accr_body":"PCA","test_object":"Materiały biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i ścieki, szkło i ceramika, wyroby inne – dawkomierze, papier, materiały opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, żywność, tekstylia, drewno","test_object_en":"Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood","methodology":"Dawka wysokoenergetycznego promieniowania elektronowego do energii 10 MeV","methodology_en":"Dose of high-energy electron radiation up to an energy of 10 MeV","parameters":[{"name":"Zakres","range":"(0,05 - 100) kGy"}],"parameters_en":[{"name":"Range","range":"(0,05 - 100) kGy"}],"technique":"Metoda spektroskopii EPR","techniques":["Metoda spektroskopii EPR"],"technique_en":"EPR spectroscopy method","computed":[],"computed_en":[],"activity":"Dawka wysokoenergetycznego promieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR","reference":"ASTM 51261-13(2020) ɛ1","norm_bases":["ASTM 51261-13(2020) ɛ1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i ścieki, szkło i ceramika, wyroby inne – dawkomierze, papier, materiały opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, żywność, tekstylia, drewno Dawka wysokoenergetycznego promieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR ASTM 51261-13(2020) ɛ1 Materialy biologiczne, wyroby chemiczne, kosmetyki, kompozyty, woda, gleba, osady i scieki, szklo i ceramika, wyroby inne – dawkomierze, papier, materialy opakowaniowe, wyroby farmaceutyczne, wyroby z tworzyw sztucznych, zywnosc, tekstylia, drewno Dawka wysokoenergetycznego promieniowania elektronowego do energii 10 MeV\nZakres (0,05 - 100) kGy\nMetoda spektroskopii EPR ASTM 51261-13(2020) ɛ1","categories":["water","materials","pharma","food","environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"能量不超过 10 MeV 的高能电子辐射剂量","parameters_zh":[{"name":"范围","range":"(0,05 - 100) kGy"}],"search_zh":"生物材料、化学制品、化妆品、复合材料、水、土壤、污泥与污水、玻璃与陶瓷、其他制品 – 剂量计、纸张、包装材料、药品、塑料制品、食品、纺织品、木材 能量不超过 10 MeV 的高能电子辐射剂量 电子顺磁共振（EPR）波谱法 范围 ASTM 51261-13(2020) ɛ1","technique_zh":"电子顺磁共振（EPR）波谱法","test_object_zh":"生物材料、化学制品、化妆品、复合材料、水、土壤、污泥与污水、玻璃与陶瓷、其他制品 – 剂量计、纸张、包装材料、药品、塑料制品、食品、纺织品、木材","search_en":"Biological materials, chemical products, cosmetics, composites, water, soil, sludge and wastewater, glass and ceramics, other products – dosimeters, paper, packaging materials, pharmaceutical products, plastic products, food, textiles, wood Dose of high-energy electron radiation up to an energy of 10 MeV EPR spectroscopy method Range ASTM 51261-13(2020) ɛ1"}],"has_pdf":true}