🇵🇱 NETWORKS SP. Z O.O. PL
Environment
NETWORKS SP. Z O.O. is a laboratory accredited by PCA under number AB 419 (Warszawa, Poland). Its accreditation scope covers 18 test methods in the following areas: Environment. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, General environment – noise from installations, equipment and indus…, Workplace environment - electromagnetic field in the workspace from…, Workplace environment – electromagnetic field in the workspace from…. Most frequently used techniques: Direct measurement method, Calculation method.
At a glance
- Accreditation number: PCA AB 419
- Methods in scope: 18
- Types of test objects: 7
- Techniques used: 2
- City: Warszawa, Poland
- Accreditation number
- AB 419
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Józefa Piusa Dziekońskiego 3, 00-728 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (7)
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- General environment – noise from installations, equipment and industrial plants — 3 methods
- Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry — 3 methods
- Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 2 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) — 2 methods
- Workplace environment – noise — 2 methods
Analytical techniques used (2)
- Direct measurement method — 10 methods
- Calculation method — 1 method
Laboratory locations
- NETWORKS SP. Z O.O. (main site) — ul. Józefa Piusa Dziekońskiego 3, 00-728 Warszawa
- ENVIRONMENTAL TESTING LABORATORY — ul. Józefa Piusa Dziekońskiego 3
Certificate information
- Issue date
- 01.09.2026
- Issue no.
- 25
Accreditation scope — test methods (18)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Environmental Testing Laboratory | |||||
| 1 | Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) | Electric field strength: in the frequency range from 80 MHz to 90 GHz Range (1,0 – 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 2 | Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) | Magnetic field strength: in the frequency range from 80 MHz to 800 MHz Range (0,010 – 1,5) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 3 | Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) | Magnetic field strength in the frequency range from 800 MHz to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 4 | Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range 50 Hz Range (0,05 – 50) kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | |
| 5 | Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry | Magnetic flux density: in the frequency range 50 Hz Range 0,5 µT – 30 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | |
| 6 | Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry | Magnetic field strength: in the frequency range 50 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | ||
| 7 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range from 80 MHz to 90 GHz Range (1,0 – 300) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 8 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength in the frequency range from 80 MHz to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 9 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Electric field strength: in the frequency range from 80 MHz to 6 GHz Range (0,2 – 200) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 10 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Magnetic field strength: in the frequency range from 80 MHz to 6 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 11 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (0,05 – 50) kV/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 12 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range 0,5 µT – 30 mT Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 13 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 14 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 – 136) dB |
Direct measurement method | Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | PN ISO 9613-2:2002 | |
| 15 | General environment – noise from installations, equipment and industrial plants | Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) |
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | PN ISO 9613-2:2002 | ||
| 16 | General environment – noise from installations, equipment and industrial plants | Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN | Calculation method | Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | PN ISO 9613-2:2002 | |
| 17 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (24 – 136) dB C-weighted peak sound pressure level Range (24 – 136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11 | |
| 18 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11 | ||
Reference standards (8)
PN ISO 9613-2:2002
PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11
PN-N-01307:1994
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)