{"lab":{"_id":"69ad52a3de79e566650fb219","accr_number":"AB 419","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Józefa Piusa Dziekońskiego 3, 00-728 Warszawa","categories":["environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"NETWORKS SP. Z O.O.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_419.pdf"],"scope_summary":"","search_text":"networks sp. z o.o. laboratorium badań środowiskowych, ul. józefa piusa dziekońskiego 3, 00-728 warszawa environment metrology pharma electronics other materials","status":"active","updated_at":"2026-03-08T14:51:15.838Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:15.838Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20419,podmiot.html","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne, hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field, noise)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne, hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field, noise)"}],"issue":{"no":"24","date":"14.01.2026"},"parse_date":"2026-07-20T07:09:37.789Z","parse_source":"script-pdfplumber","map_coord":[52.194185,21.046854],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":17},"category_scores":{"environment":17},"has_zh":true},"methods":[{"_id":"6a5dc9b1f1c10c8ce825bc06","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.)","test_object_en":"Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 80 MHz","range":"do 90 GHz"},{"name":"Zakres","range":"(1,0 – 300) V/m"}],"parameters_en":[{"name":"in the frequency range from 80 MHz","range":"do 90 GHz"},{"name":"Range","range":"(1,0 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (1,0 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (1,0 – 300) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (1,0 – 300) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) Electric field strength: Direct measurement method in the frequency range from 80 MHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 80 MHz 起","range":"do 90 GHz"},{"name":"范围","range":"(1,0 – 300) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 80 MHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bc07","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.)","test_object_en":"Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 80 MHz","range":"do 800 MHz"},{"name":"Zakres","range":"(0,010 – 1,5) A/m"}],"parameters_en":[{"name":"in the frequency range from 80 MHz","range":"do 800 MHz"},{"name":"Range","range":"(0,010 – 1,5) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 800 MHz\nZakres (0,010 – 1,5) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 800 MHz\nZakres (0,010 – 1,5) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 800 MHz\nZakres (0,010 – 1,5) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) Magnetic field strength: Direct measurement method in the frequency range from 80 MHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 80 MHz 起","range":"do 800 MHz"},{"name":"范围","range":"(0,010 – 1,5) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 80 MHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bc08","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.)","test_object_en":"Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.)","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 800 MHz do 90 GHz (z obliczeń)","methodology_en":"Magnetic field strength in the frequency range: from 800 MHz to 90 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 800 MHz do 90 GHz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natężenie pola magnetycznego w zakresie częstotliwości: od 800 MHz do 90 GHz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej, nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natezenie pola magnetycznego w zakresie czestotliwosci: od 800 MHz do 90 GHz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television, etc.) Magnetic field strength in the frequency range: from 800 MHz to 90 GHz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"},{"_id":"6a5dc9b1f1c10c8ce825bc09","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(0,05 – 50) kV/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(0,05 – 50) kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,05 – 50) kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,05 – 50) kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (0,05 – 50) kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(0,05 – 50) kV/m"}],"search_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场"},{"_id":"6a5dc9b1f1c10c8ce825bc0a","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry","methodology":"Indukcja magnetyczna:","methodology_en":"Magnetic flux density:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"0,5 μT – 30 mT"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"0,5 μT – 30 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,5 μT – 30 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,5 μT – 30 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 0,5 μT – 30 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic flux density: Direct measurement method in the frequency range 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"0,5 μT – 30 mT"}],"search_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场 磁感应强度： 直接测量法 频率范围 50 Hz 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场"},{"_id":"6a5dc9b1f1c10c8ce825bc0b","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz (z obliczeń)"}],"parameters_en":[{"name":"in the frequency range 50 Hz (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego:\nw zakresie czestotliwosci 50 Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic field strength: in the frequency range 50 Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","methodology_zh":"磁场强度：","search_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场 磁场强度： 频率 50 Hz 范围内（由计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","parameters_zh":[{"name":"频率 50 Hz 范围内（由计算得出）"}],"test_object_zh":"工作环境 － 作业空间内由电力系统及电力行业交流供电电气装置产生的电磁场"},{"_id":"6a5dc9b1f1c10c8ce825bc0c","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 80 MHz","range":"do 90 GHz"},{"name":"Zakres","range":"(1,0 – 300) V/m"}],"parameters_en":[{"name":"in the frequency range from 80 MHz","range":"do 90 GHz"},{"name":"Range","range":"(1,0 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (1,0 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (1,0 – 300) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (1,0 – 300) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 80 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 80 MHz 起","range":"do 90 GHz"},{"name":"范围","range":"(1,0 – 300) V/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 80 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9b1f1c10c8ce825bc0d","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego","methodology_en":"Magnetic field strength","parameters":[{"name":"w zakresie częstotliwości od 80 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 80 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego\nZakres:\nw zakresie czestotliwosci od 80 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength in the frequency range from 80 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","parameters_zh":[{"name":"频率范围自 80 MHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 磁场强度 频率范围自 80 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）","methodology_zh":"磁场强度"},{"_id":"6a5dc9b1f1c10c8ce825bc0e","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 80 MHz","range":"do 6 GHz"},{"name":"Zakres","range":"(0,2 – 200) V/m"}],"parameters_en":[{"name":"in the frequency range from 80 MHz","range":"do 6 GHz"},{"name":"Range","range":"(0,2 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 6 GHz\nZakres (0,2 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 6 GHz\nZakres (0,2 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 6 GHz\nZakres (0,2 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength: Direct measurement method in the frequency range from 80 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 80 MHz 起","range":"do 6 GHz"},{"name":"范围","range":"(0,2 – 200) V/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（选频测量） 电场强度： 直接测量法 频率范围自 80 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（选频测量）"},{"_id":"6a5dc9b1f1c10c8ce825bc0f","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 80 MHz","range":"do 6 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 80 MHz","range":"do 6 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 6 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 6 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 6 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength: in the frequency range from 80 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 80 MHz 起","range":"do 6 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（选频测量） 磁场强度： 频率范围自 80 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信设施周围的电磁场（选频测量）"},{"_id":"6a5dc9b1f1c10c8ce825bc10","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(0,05 – 50) kV/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(0,05 – 50) kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,05 – 50) kV/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,05 – 50) kV/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (0,05 – 50) kV/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(0,05 – 50) kV/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5dc9b1f1c10c8ce825bc11","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Indukcja magnetyczna:","methodology_en":"Magnetic flux density:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"0,5 μT – 30 mT"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"0,5 μT – 30 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,5 μT – 30 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,5 μT – 30 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 0,5 μT – 30 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"0,5 μT – 30 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁感应强度："},{"_id":"6a5dc9b1f1c10c8ce825bc12","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz (z obliczeń)"}],"parameters_en":[{"name":"in the frequency range 50 Hz (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nw zakresie czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: in the frequency range 50 Hz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度： 频率 50 Hz 范围内（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","parameters_zh":[{"name":"频率 50 Hz 范围内（由计算得出）"}]},{"_id":"6a5dc9b1f1c10c8ce825bc13","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(24 – 136) dB"}],"parameters_en":[{"name":"Range","range":"(24 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem pkt. F","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 136) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9b1f1c10c8ce825bc14","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem pkt. F","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9b1f1c10c8ce825bc15","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(24 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(24 – 136) dB"}],"parameters_en":[{"name":"Range","range":"(24 – 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(24 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (24 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (24 – 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 – pkt. 10 i strategie 3 pkt. 11","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(24 – 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9b1f1c10c8ce825bc16","lab_id":"69ad52a3de79e566650fb219","country":"PL","accr_number":"AB 419","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metod obejmujacych strategie 2 – pkt. 10 i strategie 3 pkt. 11","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metod obejmujących strategię 2 – pkt. 10 i strategię 3 pkt. 11","test_object_zh":"工作场所环境 — 噪声"}],"has_pdf":true}