🇵🇱 VEOLIA ENERGIA WARSZAWA S.A. PL

PCA AB 414 • Warszawa, Poland • 109 methods

Materials & polymersWater & wastewater

VEOLIA ENERGIA WARSZAWA S.A. is a laboratory accredited by PCA under number AB 414 (Warszawa, Poland). Its accreditation scope covers 109 test methods in the following areas: Materials & polymers, Water & wastewater. Test objects include: Pre-insulated fittingsE, Single pre-insulated pipes for the construction of water district h…, Double pre-insulated pipes for the construction of water district h…, Single pre-insulated pipes for the construction of water district c…. Most frequently used techniques: Gravimetric method, Stereoscopic method, Method of measuring geometrical quantities.

At a glance

  • Accreditation number: PCA AB 414
  • Methods in scope: 109
  • Types of test objects: 13
  • Techniques used: 6
  • City: Warszawa, Poland
Accreditation number
AB 414
Accreditation body
PCA
Address
ul. Batorego 2, 02-591 Warszawa, LABORATORIUM BADAWCZE, ul. Siemieńskiego 4
City
Warszawa, Poland

What this laboratory tests (13)

Analytical techniques used (6)

Accreditation scope — test methods (109)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Single pre-insulated pipes for the construction of water district heating networksE Wall thickness and outside diameter of the conduit pipe PN-EN 253 | EN 253
2 Single pre-insulated pipes for the construction of water district heating networksE Length of uninsulated ends of conduit pipes PN-EN 253 | EN 253
3 Single pre-insulated pipes for the construction of water district heating networksE Outside diameter and wall thickness of the sheath PN-EN 253 | EN 253
4 Single pre-insulated pipes for the construction of water district heating networksE Elongation at break
Machine range do 10 kN Tensile test
PN-EN 253 | EN 253
5 Single pre-insulated pipes for the construction of water district heating networksE Stress cracking resistance (SCR) PN-EN 253 | EN 253
6 Single pre-insulated pipes for the construction of water district heating networksE Cell size
Range do 2 mm
Stereoscopic method PN-EN 253 | EN 253
7 Single pre-insulated pipes for the construction of water district heating networksE Closed cell content, Pressure change measurement PN-EN 253 | EN 253
8 Single pre-insulated pipes for the construction of water district heating networksE Voids and blisters, Measurement of geometrical dimensions PN-EN 253 | EN 253
9 Single pre-insulated pipes for the construction of water district heating networksE Compressive strength
Machine range do 10 kN
PN-EN 253 | EN 253
10 Single pre-insulated pipes for the construction of water district heating networksE Foam density PN-EN 253 | EN 253
11 Single pre-insulated pipes for the construction of water district heating networksE Water absorption at elevated temperature Gravimetric method PN-EN 253 | EN 253
12 Single pre-insulated pipes for the construction of water district heating networksE Deviation from the axis
Range do 10 mm Measurement of geometrical quantities
PN-EN 253 | EN 253
13 Single pre-insulated pipes for the construction of water district heating networksE Shear strength in the axial direction at a temperature of 20 oC
Machine range do 40 kN
PN-EN 253 | EN 253
14 Single pre-insulated pipes for the construction of water district heating networksE Shear strength in the axial direction at a temperature of 140 oC
Machine range do 40 kN
PN-EN 253 | EN 253
15 Single pre-insulated pipes for the construction of water district heating networksE Accelerated ageing process PN-EN 253 | EN 253
16 Single pre-insulated pipes for the construction of water district heating networksE Thermal conductivity, Range up to 0,080 W/mK Method: tube apparatus PN-EN 253 | EN 253
17 Single pre-insulated pipes for the construction of water district heating networksE Artificial ageing process PN-EN 253 | EN 253
18 Single pre-insulated pipes for the construction of water district heating networksE Linear watertightness PN-EN 253 | EN 253
19 Pre-insulated joint assembly (single and double pre-insulated pipes) E Foam density PN-EN 489-1 | EN 489-1
20 Pre-insulated joint assembly (single and double pre-insulated pipes) E Compressive strength
Machine range do 10 kN
PN-EN 489-1 | EN 489-1
21 Pre-insulated joint assembly (single and double pre-insulated pipes) E Cell size
Range do 2 mm
Stereoscopic method PN-EN 489-1 | EN 489-1
22 Pre-insulated joint assembly (single and double pre-insulated pipes) E Water absorption at elevated temperature Gravimetric method PN-EN 489-1 | EN 489-1
23 Pre-insulated joint assembly (single and double pre-insulated pipes) E Closed cell content, Pressure change measurement PN-EN 489-1 | EN 489-1
24 Pre-insulated joint assembly (single and double pre-insulated pipes) E Soil load, Sand box test PN-EN 489-1 | EN 489-1
25 Pre-insulated joint assembly (single and double pre-insulated pipes) E Watertightness PN-EN 489-1 | EN 489-1
26 Pre-insulated joint assembly (single and double pre-insulated pipes) E Stress cracking resistance (SCR) PN-EN 489-1 | EN 489-1
27 Pre-insulated joint assembly (single and double pre-insulated pipes) E Bend test of plugs PN-EN 489-1 | EN 489-1
28 Single pre-insulated pipes for the construction of water district cooling networksE Wall thickness and outside diameter of the conduit pipe PN-EN 17415-1 | EN 17415-1
29 Single pre-insulated pipes for the construction of water district cooling networksE Length of uninsulated ends of conduit pipes PN-EN 17415-1 | EN 17415-1
30 Single pre-insulated pipes for the construction of water district cooling networksE Outside diameter and wall thickness of the sheath PN-EN 17415-1 | EN 17415-1
31 Single pre-insulated pipes for the construction of water district cooling networksE Elongation at break
Machine range do 10 kN Tensile test
PN-EN 17415-1 | EN 17415-1
32 Single pre-insulated pipes for the construction of water district cooling networksE Stress cracking resistance (SCR) PN-EN 17415-1 | EN 17415-1
33 Single pre-insulated pipes for the construction of water district cooling networksE Cell size
Range do 2 mm
Stereoscopic method PN-EN 17415-1 | EN 17415-1
34 Single pre-insulated pipes for the construction of water district cooling networksE Closed cell content, Pressure change measurement PN-EN 17415-1 | EN 17415-1
35 Single pre-insulated pipes for the construction of water district cooling networksE Voids and blisters, Measurement of geometrical dimensions PN-EN 17415-1 | EN 17415-1
36 Single pre-insulated pipes for the construction of water district cooling networksE Compressive strength
Machine range do 10 kN
PN-EN 17415-1 | EN 17415-1
37 Single pre-insulated pipes for the construction of water district cooling networksE Foam density PN-EN 17415-1 | EN 17415-1
38 Single pre-insulated pipes for the construction of water district cooling networksE Water absorption at elevated temperature Gravimetric method PN-EN 17415-1 | EN 17415-1
39 Single pre-insulated pipes for the construction of water district cooling networksE Deviation from the axis
Range do 10 mm Measurement of geometrical quantities
PN-EN 17415-1 | EN 17415-1
40 Single pre-insulated pipes for the construction of water district cooling networksE Thermal conductivity, Range up to 0,080 W/mK Method: tube apparatus PN-EN 17415-1 | EN 17415-1
41 Single pre-insulated pipes for the construction of water district cooling networksE Linear watertightness PN-EN 17415-1 | EN 17415-1
42 Pre-insulated fittingsE Dimensions of the pipeline pipe: Wall thickness and outside diameter PN-EN 448 | EN 448
43 Pre-insulated fittingsE Elongation at break
Machine range do 10 kN Tensile test
PN-EN 448 | EN 448
44 Pre-insulated fittingsE Stress cracking resistance (SCR) PN-EN 448 | EN 448
45 Pre-insulated fittingsE Cell size
Range do 2 mm
Stereoscopic method PN-EN 448 | EN 448
46 Pre-insulated fittingsE Closed cell content, Pressure change measurement PN-EN 448 | EN 448
47 Pre-insulated fittingsE Compressive strength
Machine range do 10 kN
PN-EN 448 | EN 448
48 Pre-insulated fittingsE Foam density PN-EN 448 | EN 448
49 Pre-insulated fittingsE Water absorption at elevated temperature Gravimetric method PN-EN 448 | EN 448
50 Pre-insulated fittingsE Length of the pipe sections without insulation at the ends of the fitting PN-EN 448 | EN 448
51 Pre-insulated fittingsE Deviation from the axis at the ends of the fitting PN-EN 448 | EN 448
52 Pre-insulated fittingsE Angular deviation of the service pipe relative to the casing at the ends of the fitting PN-EN 448 | EN 448
53 Pre-insulated fittingsE Angle between two adjacent segments of the guard PN-EN 448 | EN 448
54 Pre-insulated fittingsE Length of the casing segments at the ends of the fitting PN-EN 448 | EN 448
55 Pre-insulated fittingsE Visual assessment of the joints of the enclosure PN-EN 448 | EN 448
56 Pre-insulated fittingsE Bending of the casing connections PN-EN 448 | EN 448
57 Pre-insulated fittingsE Dimensions of the casing: Outside diameter and wall thickness of the casing PN-EN 448 | EN 448
58 Pre-insulated fittingsE Minimum insulation thickness PN-EN 448 | EN 448
59 Pre-insulated fittingsE Tolerances of the main dimensions of the fitting PN-EN 448 | EN 448
60 Pre-insulated fittingsE Guard tightness IB-SB-19-2
61 Double pre-insulated pipes for the construction of water district heating networksE Wall thickness and outside diameter of the conduit pipe PN-EN 15698-1 | EN 15698-1
62 Double pre-insulated pipes for the construction of water district heating networksE Length of uninsulated ends of conduit pipes PN-EN 15698-1 | EN 15698-1
63 Double pre-insulated pipes for the construction of water district heating networksE Outside diameter and wall thickness of the sheath PN-EN 15698-1 | EN 15698-1
64 Double pre-insulated pipes for the construction of water district heating networksE Cell size
Range do 2 mm
Stereoscopic method PN-EN 15698-1 | EN 15698-1
65 Double pre-insulated pipes for the construction of water district heating networksE Closed cell content, Pressure change measurement PN-EN 15698-1 | EN 15698-1
66 Double pre-insulated pipes for the construction of water district heating networksE Voids and blisters, Measurement of geometrical dimensions PN-EN 15698-1 | EN 15698-1
67 Double pre-insulated pipes for the construction of water district heating networksE Compressive strength
Machine range do 10 kN
PN-EN 15698-1 | EN 15698-1
68 Double pre-insulated pipes for the construction of water district heating networksE Foam density PN-EN 15698-1 | EN 15698-1
69 Double pre-insulated pipes for the construction of water district heating networksE Water absorption at elevated temperature Gravimetric method PN-EN 15698-1 | EN 15698-1
70 Double pre-insulated pipes for the construction of water district heating networksE Alignment of the ends of pipeline pipes PN-EN 15698-1 | EN 15698-1
71 Double pre-insulated pipes for the construction of water district heating networksE Distance between service pipes Method of measuring geometrical quantities PN-EN 15698-1 | EN 15698-1
72 Double pre-insulated pipes for the construction of water district heating networksE Torsion of line pipes Method of measuring geometrical quantities PN-EN 15698-1 | EN 15698-1
73 Double pre-insulated pipes for the construction of water district heating networksE Deviation from the axis Method of measuring geometrical quantities PN-EN 15698-1 | EN 15698-1
74 Double pre-insulated pipes for the construction of water district heating networksE Shear strength in the axial direction
Machine range do 40 kN
PN-EN 15698-1 | EN 15698-1
75 Fibrous products, Cellular plastics E Thermal conductivity, Range up to 0,080 W/mK Method: tube apparatus PN-EN ISO 8497
76 Fibrous products, Cellular plastics E Thermal conductivity
Range do 0,080 W/mK
Method: plate apparatus PN-ISO 8301
77 Fibrous products, Cellular plastics E Density PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098
78 Fibrous products, Cellular plastics E Compressive strength
Machine range do 10 kN
PN-EN ISO 29469 | PN-EN ISO 844 Metoda A
79 Fibrous products, Cellular plastics E Content of closed/open cells, Pressure change measurement PN-EN ISO 4590 Metoda 1
80 Fibrous products, Cellular plastics E Cell size
Range do 2 mm
Stereoscopic method PN-EN 253 | EN 253
81 Fibrous products, Cellular plastics E Water absorption at elevated temperature Gravimetric method PN-EN 253 | EN 253
82 Fibrous products, Cellular plastics E Thermal resistance
Range of the heating chamber do 250 °C Range of the testing machine: do 10 kN
Method of measuring geometrical quantities PB-01
83 Fibrous products, Cellular plastics E Voids and blisters PN-EN 253 | EN 253
84 Fibrous products, Cellular plastics E Stress-strain characteristic in compression PN-EN ISO 3386-1 | PN-EN 13941-1
85 Fibrous products, Cellular plastics E Compression set, Deformation after compression PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1
86 Fibrous products, Cellular plastics E Linear dimensions PN-EN ISO 1923
87 Fibrous products, Cellular plastics E Water absorption by the hydrostatic buoyancy method PN-93/C-89084 | ISO 2896
88 Thermoplastic plasticsE Bend test PN-EN 12814-1
89 Thermoplastic plasticsE Stress cracking resistance (SCR) ISO 16770
90 Thermoplastic plasticsE Elongation at break PN-EN ISO 527-1
91 Thermoplastic plasticsE Tensile strength
Machine range do 10 kN
PN-EN ISO 527-1
92 Thermoplastic plasticsE Tensile test PN-EN ISO 527-1
93 Heat-shrinkable end capE Leak tightness IB-SB-19-1 | IB-SB-19-2
94 Thermoplastic plastics Degree of crosslinking Method for determining gel content PN-EN ISO 10147:2013-06 | PN-EN 579:2001
95 Thermoplastic plastics Elongation at break Tensile strength Yield strength
Machine range do 10 kN Tensile test
PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08
96 Fibrous products, Cellular plastics Geometric dimensions of the insulation shell PN-EN ISO 12628:2023-02
97 Fibrous products, Cellular plastics Dimensions and tolerances PN-EN ISO 12628:2023-02
98 Fibrous products, Cellular plastics Linearity PN-EN ISO 12628:2023-02
99 Fibrous products, Cellular plastics Squareness PN-EN ISO 12628:2023-02
100 Fibrous products, Cellular plastics Maximum service temperature of pipe insulation PN-EN ISO 18096:2023-02
101 Fibrous products, Cellular plastics Compressive strength PN-EN ISO 29469:2023-05
102 Fibrous products, Cellular plastics Compressive stress
Machine range do 10 kN
PN-EN ISO 29469:2023-05
103 Fibrous products, Cellular plastics Thermal resistance
Range do 0,080 W/mK
Method: plate apparatus PN-EN ISO 12667:2002
104 Fibrous products, Cellular plastics Elongation at break PN-EN ISO 1798:2009
105 Fibrous products, Cellular plastics Tensile strength
Machine range do 10 kN
PN-EN ISO 1798:2009
106 Fibrous products, Cellular plastics Tensile test PN-EN ISO 1798:2009
107 Single pre-insulated pipes Shear strength in the tangential direction
Machine range do 40 kN Shear strength in the direction
PN-EN 253+A2:2015-12
108 for the construction of water networks stycznym PN-EN 253+A2:2015-12
109 district heating
Machine range do 40 kN
PN-EN 253+A2:2015-12

Reference standards (41)

EN 15698-1
EN 17415-1
EN 253
EN 448
EN 489-1
IB-SB-19-1
IB-SB-19-2
ISO 16770
ISO 1856
ISO 2896
PB-01
PN-93/C-89084
PN-EN 12814-1
PN-EN 13941-1
PN-EN 15698-1
PN-EN 1602
PN-EN 17415-1
PN-EN 253
PN-EN 253+A2:2015-12
PN-EN 448
PN-EN 489-1
PN-EN 579:2001
PN-EN ISO 10147:2013-06
PN-EN ISO 12628:2023-02
PN-EN ISO 12667:2002
PN-EN ISO 1798:2009
PN-EN ISO 18096:2023-02
PN-EN ISO 18098
PN-EN ISO 1856
PN-EN ISO 1923
PN-EN ISO 29469
PN-EN ISO 29469:2023-05
PN-EN ISO 3386-1
PN-EN ISO 4590 Metoda 1
PN-EN ISO 527-1
PN-EN ISO 6259-1:2015-05
PN-EN ISO 6259-3:2015-08
PN-EN ISO 844 Metoda A
PN-EN ISO 845
PN-EN ISO 8497
PN-ISO 8301