🇵🇱 RADIOLOG S.C. PL

PCA AB 413 • Szczecin, Poland • 10 methods

Electronics & EMCEnvironment

RADIOLOG S.C. is a laboratory accredited by PCA under number AB 413 (Szczecin, Poland). Its accreditation scope covers 10 test methods in the following areas: Electronics & EMC, Environment. Test objects include: Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field in the workspace from…, Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field originating from radi…. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 413
  • Methods in scope: 10
  • Types of test objects: 4
  • Techniques used: 1
  • City: Szczecin, Poland
Accreditation number
AB 413
Accreditation body
PCA
Address
Janusz Rzepka,, Mariusz Piotrowski, Mateusz Rzepka, ul. Dworska 46, 71-026 Szczecin
City
Szczecin, Poland

What this laboratory tests (4)

Analytical techniques used (1)

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − electromagnetic field originating from radiocommunication systems: hand-held, body-worn and vehicle-mounted radio stations (radiotelephones) Electric field strength:
in the frequency range from 0,1 MHz do 8 GHz Range (0,5 – 1000) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.
2 Workplace environment − electromagnetic field originating from radiocommunication systems: hand-held, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic field strength:
in the frequency range from 27 MHz do 1,0 GHz Range (0,01 – 1,5) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.
3 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 0,1 MHz do 8 GHz Range (0,5 – 1000) V/m in the frequency range from 80 MHz do 90 GHz Range (0,5 – 350) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
4 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 Hz do 1000 MHz Range (0,01 – 1,5) A/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
5 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz do 90 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
6 Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength:
in the frequency range from 500 MHz do 5 GHz Range (0,5 – 100) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
7 Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength:
in the frequency range from 500 MHz do 5 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
8 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations) Electric field strength:
in the frequency range from 0,1 MHz do 8 GHz Range (0,5 – 1000) V/m in the frequency range from 80 MHz do 90 GHz Range (0,5 – 350) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
9 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations) Magnetic field strength:
in the frequency range from 27 MHz do 1 GHz Range (0,01 – 1,5) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
10 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations) Magnetic field strength:
in the frequency range from 0,8 GHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131

Reference standards (4)

PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)