{"lab":{"_id":"69ad52a3de79e566650fb20f","accr_number":"AB 413","country":"PL","accr_body":"PCA","address":"Janusz Rzepka,, Mariusz Piotrowski, Mateusz Rzepka, ul. Dworska 46, 71-026 Szczecin","categories":["environment"],"city":"Szczecin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"RADIOLOG S.C.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_413.pdf"],"scope_summary":"","search_text":"radiolog s.c. janusz rzepka,, mariusz piotrowski, mateusz rzepka, ul. dworska 46, 71-026 szczecin environment pharma electronics other metrology","status":"active","updated_at":"2026-03-08T14:51:14.887Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:14.887Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20413,podmiot.html","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"22","date":"16.01.2026"},"parse_date":"2026-07-20T07:09:37.615Z","parse_source":"script-pdfplumber","map_coord":[53.417262,14.499514],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":10},"category_scores":{"environment":10},"has_zh":true},"methods":[{"_id":"6a5dc9b1f1c10c8ce825bb3f","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych: radiostacje (radiotelefony) doręczne, nasobne i przewoźne","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication systems: hand-held, body-worn and vehicle-mounted radio stations (radiotelephones)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 8 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 0,1 MHz","range":"do 8 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych: radiostacje (radiotelefony) doręczne, nasobne i przewoźne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych: radiostacje (radiotelefony) doreczne, nasobne i przewozne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field originating from radiocommunication systems: hand-held, body-worn and vehicle-mounted radio stations (radiotelephones) Electric field strength: Direct measurement method in the frequency range from 0,1 MHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 8 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb40","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych: radiostacje (radiotelefony) doręczne, nasobne i przewoźne","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication systems: hand-held, body-worn and vehicle-mounted radio stations (radiotelephones)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 27 MHz","range":"do 1,0 GHz"},{"name":"Zakres","range":"(0,01 – 1,5) A/m"}],"parameters_en":[{"name":"in the frequency range from 27 MHz","range":"do 1,0 GHz"},{"name":"Range","range":"(0,01 – 1,5) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1,0 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych: radiostacje (radiotelefony) doręczne, nasobne i przewoźne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1,0 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych: radiostacje (radiotelefony) doreczne, nasobne i przewozne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 27 MHz do 1,0 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field originating from radiocommunication systems: hand-held, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic field strength: Direct measurement method in the frequency range from 27 MHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 27 MHz 起","range":"do 1,0 GHz"},{"name":"范围","range":"(0,01 – 1,5) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 27 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura badawcza PB-02 wydanie z dnia 30.08.2025 r.","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb41","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 8 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"w zakresie częstotliwości od 80 MHz","range":"do 90 GHz"},{"name":"Zakres","range":"(0,5 – 350) V/m"}],"parameters_en":[{"name":"in the frequency range from 0,1 MHz","range":"do 8 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"in the frequency range from 80 MHz","range":"do 90 GHz"},{"name":"Range","range":"(0,5 – 350) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,5 – 350) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,5 – 350) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (0,5 – 350) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 0,1 MHz Range in the frequency range from 80 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 8 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"频率范围自 80 MHz 起","range":"do 90 GHz"},{"name":"范围","range":"(0,5 – 350) V/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 频率范围自 80 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9b1f1c10c8ce825bb42","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 1000 MHz"},{"name":"Zakres","range":"(0,01 – 1,5) A/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 1000 MHz"},{"name":"Range","range":"(0,01 – 1,5) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 1000 MHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 1000 MHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 1000 MHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: Direct measurement method in the frequency range from 10 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 1000 MHz"},{"name":"范围","range":"(0,01 – 1,5) A/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 频率范围自 10 Hz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9b1f1c10c8ce825bb43","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 10 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: in the frequency range from 10 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 MHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 10 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9b1f1c10c8ce825bb44","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 500 MHz","range":"do 5 GHz"},{"name":"Zakres","range":"(0,5 – 100) V/m"}],"parameters_en":[{"name":"in the frequency range from 500 MHz","range":"do 5 GHz"},{"name":"Range","range":"(0,5 – 100) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 500 MHz do 5 GHz\nZakres (0,5 – 100) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 500 MHz do 5 GHz\nZakres (0,5 – 100) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 500 MHz do 5 GHz\nZakres (0,5 – 100) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength: Direct measurement method in the frequency range from 500 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 500 MHz","range":"do 5 GHz"},{"name":"范围","range":"(0,5 – 100) V/m"}],"search_zh":"电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb45","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 500 MHz","range":"do 5 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 500 MHz","range":"do 5 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 500 MHz do 5 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 500 MHz do 5 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 500 MHz do 5 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength: in the frequency range from 500 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 500 MHz","range":"do 5 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"},{"_id":"6a5dc9b1f1c10c8ce825bb46","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemów telefonii komórkowej)","test_object_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 8 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"w zakresie częstotliwości od 80 MHz","range":"do 90 GHz"},{"name":"Zakres","range":"(0,5 – 350) V/m"}],"parameters_en":[{"name":"in the frequency range from 0,1 MHz","range":"do 8 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"in the frequency range from 80 MHz","range":"do 90 GHz"},{"name":"Range","range":"(0,5 – 350) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,5 – 350) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemów telefonii komórkowej) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,5 – 350) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemow telefonii komorkowej) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 8 GHz\nZakres (0,5 – 1000) V/m\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (0,5 – 350) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations) Electric field strength: Direct measurement method in the frequency range from 0,1 MHz Range in the frequency range from 80 MHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 8 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"频率范围自 80 MHz 起","range":"do 90 GHz"},{"name":"范围","range":"(0,5 – 350) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 频率范围自 80 MHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb47","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemów telefonii komórkowej)","test_object_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 27 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1,5) A/m"}],"parameters_en":[{"name":"in the frequency range from 27 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1,5) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemów telefonii komórkowej) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemow telefonii komorkowej) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 27 MHz do 1 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations) Magnetic field strength: Direct measurement method in the frequency range from 27 MHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 27 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1,5) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 27 MHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb48","lab_id":"69ad52a3de79e566650fb20f","country":"PL","accr_number":"AB 413","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemów telefonii komórkowej)","test_object_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 90 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemów telefonii komórkowej) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (nadawcze systemy tele i radiokomunikacyjne – radio, telewizja, itp., stacje bazowe systemow telefonii komorkowej) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 90 GHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc., mobile telephony base stations) Magnetic field strength: in the frequency range from 0,8 GHz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 0,8 GHz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"}],"has_pdf":true}