EKOPERFEX is a laboratory accredited by PCA under number AB 408 (Słupsk, Poland). Its accreditation scope covers 33 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment - air, Workplace environment - emergency lighting, Workplace environment - electromagnetic field, General environment - noise from installations, equipment and indus…. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.
At a glance
- Accreditation number: PCA AB 408
- Methods in scope: 33
- Types of test objects: 13
- Techniques used: 5
- City: Słupsk, Poland
- Accreditation number
- AB 408
- Accreditation body
- PCA
- Address
- Przemysław Kubina, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Portowa 13b, 76-200 Słupsk
- City
- Słupsk, Poland
What this laboratory tests (13)
- Workplace environment - air — 7 methods
- Workplace environment - emergency lighting — 4 methods
- Workplace environment - electromagnetic field — 3 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Workplace environment - cold microclimate — 2 methods
- Workplace environment - hand-arm vibration — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment - ultrasonic noise — 2 methods
- Workplace environment - whole-body vibration — 2 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices — 1 method
Analytical techniques used (5)
- Direct measurement method — 15 methods
- Gravimetric method — 2 methods
- Personal dosimetry method — 2 methods
- Direct measurement method (simplified) — 1 method
- Electrochemical method — 1 method
Laboratory locations
- LABORATORIUM BADAŃ ŚRODOWISKOWYCH — ul. Portowa 13b
Accreditation scope — test methods (33)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Environmental Testing Laboratory | |||||
| 1 | Workplace environment - air | Air sampling for occupational exposure assessment to: dust agents – inhalable fraction – respirable fraction | Personal dosimetry method | PN-Z-04008-7:2002+ Az1:2004 | |
| 2 | Workplace environment - air | Pobieranie próbek powietrza do oceny narażenia zawodowego na: substancje organiczne, w tym – frakcja wdychalna substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna | Personal dosimetry method | PN-Z-04008-7:2002+ Az1:2004 | |
| 3 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+ Az1:2004 | ||
| 4 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,10 – 20,83) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08 | |
| 5 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range (0,10 – 21,93) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08 | |
| 6 | Workplace environment - air | Carbon monoxide concentration Range (2,32 – 232) mg/m3 Range (2 – 200) ppm |
Electrochemical method | PB-034 wydanie 3 z dnia 03.07.2025 r. | |
| 7 | Workplace environment - air | Exposure indices (calculated) | PB-034 wydanie 3 z dnia 03.07.2025 r. | ||
| 8 | Workplace environment - indoor electric lighting | Illuminance Range (5 – 9000) lx |
Direct measurement method | PB-001 wydanie 3 z dnia 25.06.2026 r. | |
| 9 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | PB-001 wydanie 3 z dnia 25.06.2026 r. | ||
| 10 | Workplace environment - emergency lighting | Illuminance Range (0,5 – 500) lx |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 | |
| 11 | Workplace environment - emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 | ||
| 12 | Workplace environment - emergency lighting | Closing time Range (1 – 60) s |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 | |
| 13 | Workplace environment - emergency lighting | Minimum duration of lighting operation Range (1 - 3600) s |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 | |
| 14 | Workplace environment - hot microclimate | Air temperature Range (20 – 40) °C Natural wet bulb temperature Range (20 – 40) °C Black globe temperature Range (20 – 40) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 15 | Workplace environment - hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 16 | Workplace environment - cold microclimate | Air temperature Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5,00) m/s |
Direct measurement method | PN-EN ISO 11079:2008+Ap1:2013-10 | |
| 17 | Workplace environment - cold microclimate | IREQ min index, IREQ neutral index, tWC index (calculated) | PN-EN ISO 11079:2008+Ap1:2013-10 | ||
| 18 | Workplace environment - moderate microclimate | Air temperature Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5,00) m/s |
Direct measurement method | PN-EN ISO7730:2006+Ap2:2016-04P | |
| 19 | Workplace environment - moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO7730:2006+Ap2:2016-04P | ||
| 20 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (44 - 136) dB C-weighted peak sound pressure level Range (44 - 136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11. | |
| 21 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11. | ||
| 22 | Workplace environment - hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,06 – 100) m/s2 |
Direct measurement method | PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 23 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 24 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,07 – 100) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 25 | Workplace environment - whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 26 | Workplace environment - ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Range (64 - 158) dB |
Direct measurement method | PN-Z-01339-2020-12 | |
| 27 | Workplace environment - ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01339-2020-12 | ||
| 28 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 - 136) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | |
| 29 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | ||
| 30 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density in the frequency range from 10 to 400 x 103 Hz Range 1 μT – 20 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331) |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
| 31 | Workplace environment - electromagnetic field | Electric field strength in the frequency range: from 5 Hz to 29 * 106 Hz Range 1 V/m – 50 kV/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 32 | Workplace environment - electromagnetic field | Magnetic field strength in the frequency range: from 10 * 103 Hz to 29 * 106 Hz Range (0,01 – 200) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 33 | Workplace environment - electromagnetic field | Magnetic flux density in the frequency range: 0 Hz Range 0,1 mT – 1T 10Hz – 500 * 103 Hz Range 1 μT – 20 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
Reference standards (21)
PB-001 wydanie 3 z dnia 25.06.2026 r.
PB-034 wydanie 3 z dnia 03.07.2025 r.
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5
PN-EN ISO 11079:2008+Ap1:2013-10
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.
PN-EN ISO7730:2006+Ap2:2016-04P
PN-EN-ISO 5349-1:2004
PN-EN-ISO 5349-2:2004
PN-N-01307:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
PN-Z-01339-2020-12
PN-Z-04008-7:2002+ Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05+Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F