{"lab":{"_id":"69ad52a3de79e566650fb207","accr_number":"AB 408","country":"PL","accr_body":"PCA","address":"Przemysław Kubina, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Portowa 13b, 76-200 Słupsk","categories":["environment","construction"],"city":"Słupsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":33,"name":"EKOPERFEX","parse_status":"parsed","parse_version":3,"pdf_files":["AB_408.pdf"],"scope_summary":"","search_text":"ekoperfex przemysław kubina, laboratorium badań środowiskowych, ul. portowa 13b, 76-200 słupsk environment materials other construction electronics metrology pharma","status":"active","updated_at":"2026-03-08T14:51:14.289Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:03:13.569Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20408,podmiot.html","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling - working environment (harmful factors – air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, oświetlenie, drgania, pola elektromagnetyczne, mikroklimat),","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise, ultrasonic noise, lighting, vibration, electromagnetic field, microclimate)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek powietrza","en":"Sampling of air"}],"issue":{"no":"29","date":"30.07.2026"},"parse_date":"2026-08-17T20:03:13.569Z","parse_source":"agent-claude-code","map_coord":[54.483915,17.015991],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH","address":"ul. Portowa 13b","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/d1327d04d4a7e0ef8ac5124865e052fa/AB%20408.pdf","has_en":true,"category_counts":{"environment":33,"construction":2,"materials":1},"category_scores":{"environment":30.25,"construction":0.11,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a836901af14b9c0e7b1da39","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na: czynniki pyłowe – frakcja wdychalna – frakcja respirabilna","parameters":[],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na: czynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+ Az1:2004","norm_bases":["PN-Z-04008-7:2002+ Az1:2004"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na: czynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+ Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na: czynniki pylowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+ Az1:2004","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Air sampling for occupational exposure assessment to: dust agents – inhalable fraction – respirable fraction","search_en":"Workplace environment - air Air sampling for occupational exposure assessment to: dust agents – inhalable fraction – respirable fraction Personal dosimetry method Environmental Testing Laboratory PN-Z-04008-7:2002+ Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 个体剂量测定法 环境检测实验室 PN-Z-04008-7:2002+ Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da3a","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na: substancje organiczne, w tym – frakcja wdychalna substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna","parameters":[],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na: substancje organiczne, w tym – frakcja wdychalna substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+ Az1:2004","norm_bases":["PN-Z-04008-7:2002+ Az1:2004"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na: substancje organiczne, w tym – frakcja wdychalna substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+ Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na: substancje organiczne, w tym – frakcja wdychalna substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna metale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+ Az1:2004","categories":["materials","environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","search_en":"Workplace environment - air Personal dosimetry method Environmental Testing Laboratory PN-Z-04008-7:2002+ Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 个体剂量测定法 环境检测实验室 PN-Z-04008-7:2002+ Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da3b","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+ Az1:2004","norm_bases":["PN-Z-04008-7:2002+ Az1:2004"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+ Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+ Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) Environmental Testing Laboratory PN-Z-04008-7:2002+ Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 环境检测实验室 PN-Z-04008-7:2002+ Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da3c","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,10 – 20,83) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,10 – 20,83) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,10 – 20,83) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nZakres (0,10 – 20,83) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"Range","range":"(0,10 – 20,83) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method Environmental Testing Laboratory apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,10 – 20,83) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 环境检测实验室 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境检测实验室","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a836901af14b9c0e7b1da3d","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 21,93) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,10 – 21,93) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,10 – 21,93) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,10 – 21,93) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,10 – 21,93) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method Environmental Testing Laboratory apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 21,93) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 环境检测实验室 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境检测实验室","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a836901af14b9c0e7b1da3e","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,32 – 232) mg/m3"},{"name":"Zakres","range":"(2 – 200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna","reference":"PB-034 wydanie 3 z dnia 03.07.2025 r.","norm_bases":["PB-034 wydanie 3 z dnia 03.07.2025 r."],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna PB-034 wydanie 3 z dnia 03.07.2025 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna PB-034 wydanie 3 z dnia 03.07.2025 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,32 – 232) mg/m3"},{"name":"Range","range":"(2 – 200) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Environmental Testing Laboratory Range Range PB-034 wydanie 3 z dnia 03.07.2025 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,32 – 232) mg/m3"},{"name":"范围","range":"(2 – 200) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 环境检测实验室 范围 范围 PB-034 wydanie 3 z dnia 03.07.2025 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da3f","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-034 wydanie 3 z dnia 03.07.2025 r.","norm_bases":["PB-034 wydanie 3 z dnia 03.07.2025 r."],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-034 wydanie 3 z dnia 03.07.2025 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-034 wydanie 3 z dnia 03.07.2025 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) Environmental Testing Laboratory PB-034 wydanie 3 z dnia 03.07.2025 r.","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） 环境检测实验室 PB-034 wydanie 3 z dnia 03.07.2025 r.","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境检测实验室","methodology_zh":"暴露指数（计算值）"},{"_id":"6a836901af14b9c0e7b1da40","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 9000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 9000) lx\nMetoda pomiarowa bezpośrednia","reference":"PB-001 wydanie 3 z dnia 25.06.2026 r.","norm_bases":["PB-001 wydanie 3 z dnia 25.06.2026 r."],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 9000) lx\nMetoda pomiarowa bezpośrednia PB-001 wydanie 3 z dnia 25.06.2026 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 9000) lx\nMetoda pomiarowa bezposrednia PB-001 wydanie 3 z dnia 25.06.2026 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 9000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Environmental Testing Laboratory Range PB-001 wydanie 3 z dnia 25.06.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 9000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 环境检测实验室 范围 PB-001 wydanie 3 z dnia 25.06.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da41","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PB-001 wydanie 3 z dnia 25.06.2026 r.","norm_bases":["PB-001 wydanie 3 z dnia 25.06.2026 r."],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PB-001 wydanie 3 z dnia 25.06.2026 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PB-001 wydanie 3 z dnia 25.06.2026 r.","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) Environmental Testing Laboratory PB-001 wydanie 3 z dnia 25.06.2026 r.","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 环境检测实验室 PB-001 wydanie 3 z dnia 25.06.2026 r.","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da42","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Environmental Testing Laboratory Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 环境检测实验室 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a836901af14b9c0e7b1da43","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) Environmental Testing Laboratory PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","test_object_en":"Workplace environment - emergency lighting","lab_section_zh":"环境检测实验室","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） 环境检测实验室 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a836901af14b9c0e7b1da44","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(1 – 60) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (1 – 60) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Czas załączania\nZakres (1 – 60) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 Srodowisko pracy - oswietlenie awaryjne Czas zalaczania\nZakres (1 – 60) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Closing time","parameters_en":[{"name":"Range","range":"(1 – 60) s"}],"search_en":"Workplace environment - emergency lighting Closing time Direct measurement method Environmental Testing Laboratory Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(1 – 60) s"}],"search_zh":"工作场所环境 — 应急照明 接通时间 直接测量法 环境检测实验室 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"接通时间"},{"_id":"6a836901af14b9c0e7b1da45","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Minimalny czas stosowania oświetlenia","parameters":[{"name":"Zakres","range":"(1 - 3600) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Minimalny czas stosowania oświetlenia\nZakres (1 - 3600) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Minimalny czas stosowania oświetlenia\nZakres (1 - 3600) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5 Srodowisko pracy - oswietlenie awaryjne Minimalny czas stosowania oswietlenia\nZakres (1 - 3600) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Minimum duration of lighting operation","parameters_en":[{"name":"Range","range":"(1 - 3600) s"}],"search_en":"Workplace environment - emergency lighting Minimum duration of lighting operation Direct measurement method Environmental Testing Laboratory Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(1 - 3600) s"}],"search_zh":"工作场所环境 — 应急照明 照明的最短使用时间 直接测量法 环境检测实验室 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"照明的最短使用时间"},{"_id":"6a836901af14b9c0e7b1da46","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20 – 40) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(20 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20 – 40) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20 – 40) °C\nTemperatura wilgotna naturalna\nZakres (20 – 40) °C\nTemperatura poczernionej kuli\nZakres (20 – 40) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20 – 40) °C\nTemperatura wilgotna naturalna\nZakres (20 – 40) °C\nTemperatura poczernionej kuli\nZakres (20 – 40) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20 – 40) °C\nTemperatura wilgotna naturalna\nZakres (20 – 40) °C\nTemperatura poczernionej kuli\nZakres (20 – 40) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(20 – 40) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(20 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(20 – 40) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Environmental Testing Laboratory Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(20 – 40) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(20 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(20 – 40) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 环境检测实验室 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da47","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) Environmental Testing Laboratory PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） 环境检测实验室 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da48","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,00) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,00) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008+Ap1:2013-10","norm_bases":["PN-EN ISO 11079:2008+Ap1:2013-10"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,00) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008+Ap1:2013-10 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,00) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008+Ap1:2013-10","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,00) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Environmental Testing Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008+Ap1:2013-10","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,00) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 环境检测实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008+Ap1:2013-10","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da49","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQ min, Wskaźnik IREQ neutral, Wskaźnik tWC (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQ min, Wskaźnik IREQ neutral, Wskaźnik tWC (z obliczeń)","reference":"PN-EN ISO 11079:2008+Ap1:2013-10","norm_bases":["PN-EN ISO 11079:2008+Ap1:2013-10"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQ min, Wskaźnik IREQ neutral, Wskaźnik tWC (z obliczeń) PN-EN ISO 11079:2008+Ap1:2013-10 Srodowisko pracy - mikroklimat zimny Wskaznik IREQ min, Wskaznik IREQ neutral, Wskaznik tWC (z obliczen) PN-EN ISO 11079:2008+Ap1:2013-10","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"IREQ min index, IREQ neutral index, tWC index (calculated)","search_en":"Workplace environment - cold microclimate IREQ min index, IREQ neutral index, tWC index (calculated) Environmental Testing Laboratory PN-EN ISO 11079:2008+Ap1:2013-10","test_object_en":"Workplace environment - cold microclimate","search_zh":"工作场所环境 — 低温微气候 环境检测实验室 PN-EN ISO 11079:2008+Ap1:2013-10","test_object_zh":"工作场所环境 — 低温微气候","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da4a","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,00) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,00) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO7730:2006+Ap2:2016-04P","norm_bases":["PN-EN ISO7730:2006+Ap2:2016-04P"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,00) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO7730:2006+Ap2:2016-04P Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,00) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO7730:2006+Ap2:2016-04P","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,00) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Environmental Testing Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO7730:2006+Ap2:2016-04P","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,00) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 环境检测实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO7730:2006+Ap2:2016-04P","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da4b","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO7730:2006+Ap2:2016-04P","norm_bases":["PN-EN ISO7730:2006+Ap2:2016-04P"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO7730:2006+Ap2:2016-04P Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO7730:2006+Ap2:2016-04P","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) Environmental Testing Laboratory PN-EN ISO7730:2006+Ap2:2016-04P","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） 环境检测实验室 PN-EN ISO7730:2006+Ap2:2016-04P","test_object_zh":"工作场所环境 — 中等微气候","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da4c","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(44 - 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(44 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 - 136) dB\nSzczytowy poziom dźwięku C\nZakres (44 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11."],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 - 136) dB\nSzczytowy poziom dźwięku C\nZakres (44 - 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11. Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (44 - 136) dB\nSzczytowy poziom dzwieku C\nZakres (44 - 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkt 10 i 11.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(44 - 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(44 - 136) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Environmental Testing Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(44 - 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(44 - 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 环境检测实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da4d","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11."],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11. Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkt 10 i 11.","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: Environmental Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 环境检测实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11.","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da4e","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - drgania przenoszone przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,06 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN-ISO 5349-1:2004","PN-EN-ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania przenoszone przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania przenoszone przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,06 – 100) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Environmental Testing Laboratory Range PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,06 – 100) m/s2"}],"search_zh":"工作环境 － 经上肢传递的振动 频率计权振动加速度有效值 直接测量法 环境检测实验室 范围 PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作环境 － 经上肢传递的振动"},{"_id":"6a836901af14b9c0e7b1da4f","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - drgania przenoszone przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN-ISO 5349-1:2004","PN-EN-ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania przenoszone przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania przenoszone przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) Environmental Testing Laboratory PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作环境 － 经上肢传递的振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） 环境检测实验室 PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","lab_section_zh":"环境检测实验室","test_object_zh":"工作环境 － 经上肢传递的振动"},{"_id":"6a836901af14b9c0e7b1da50","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,07 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,07 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,07 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,07 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,07 – 100) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Environmental Testing Laboratory Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,07 – 100) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的振动 频率计权振动加速度有效值 直接测量法 环境检测实验室 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a836901af14b9c0e7b1da51","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) Environmental Testing Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","lab_section_zh":"环境检测实验室","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","search_zh":"工作环境 － 对人体产生全身作用的振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） 环境检测实验室 PN-EN 14253+A1:2011","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a836901af14b9c0e7b1da52","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - hałas ultradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(64 - 158) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (64 - 158) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339-2020-12","norm_bases":["PN-Z-01339-2020-12"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (64 - 158) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339-2020-12 Srodowisko pracy - halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (64 - 158) dB\nMetoda pomiarowa bezposrednia PN-Z-01339-2020-12","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(64 - 158) dB"}],"search_en":"Workplace environment - ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Environmental Testing Laboratory Range PN-Z-01339-2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment - ultrasonic noise","parameters_zh":[{"name":"范围","range":"(64 - 158) dB"}],"search_zh":"工作环境 － 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 环境检测实验室 范围 PN-Z-01339-2020-12","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作环境 － 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a836901af14b9c0e7b1da53","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - hałas ultradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339-2020-12","norm_bases":["PN-Z-01339-2020-12"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339-2020-12 Srodowisko pracy - halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339-2020-12","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: Environmental Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339-2020-12","test_object_en":"Workplace environment - ultrasonic noise","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 － 超声噪声 环境检测实验室 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339-2020-12","lab_section_zh":"环境检测实验室","test_object_zh":"工作环境 － 超声噪声"},{"_id":"6a836901af14b9c0e7b1da54","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 - 136) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 - 136) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 - 136) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Environmental Testing Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 - 136) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 环境检测实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da55","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Environmental Testing Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 环境检测实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声","lab_section_zh":"环境检测实验室"},{"_id":"6a836901af14b9c0e7b1da56","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna","parameters":[{"name":"w zakresie częstotliwości od 10 do 400 x 103 Hz"},{"name":"Zakres","range":"1 μT – 20 mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna\nZakres:\nw zakresie częstotliwości od 10 do 400 x 103 Hz\nZakres 1 μT – 20 mT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna\nZakres:\nw zakresie częstotliwości od 10 do 400 x 103 Hz\nZakres 1 μT – 20 mT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna\nZakres:\nw zakresie czestotliwosci od 10 do 400 x 103 Hz\nZakres 1 μT – 20 mT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Magnetic flux density","parameters_en":[{"name":"in the frequency range from 10 to 400 x 103 Hz"},{"name":"Range","range":"1 μT – 20 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density Direct measurement method (simplified) Environmental Testing Laboratory in the frequency range from 10 to 400 x 103 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"w zakresie częstotliwości od 10 do 400 x 103 Hz"},{"name":"范围","range":"1 μT – 20 mT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁感应强度 直接测量法（简化） 环境检测实验室 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）","methodology_zh":"磁感应强度"},{"_id":"6a836901af14b9c0e7b1da57","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 29 * 106 Hz","parameters":[{"name":"Zakres","range":"1 V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 29 * 106 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 29 * 106 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pole elektromagnetyczne Natezenie pola elektrycznego w zakresie czestotliwosci: od 5 Hz do 29 * 106 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Electric field strength in the frequency range: from 5 Hz to 29 * 106 Hz","parameters_en":[{"name":"Range","range":"1 V/m – 50 kV/m"}],"search_en":"Workplace environment - electromagnetic field Electric field strength in the frequency range: from 5 Hz to 29 * 106 Hz Direct measurement method Environmental Testing Laboratory Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"范围","range":"1 V/m – 50 kV/m"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 环境检测实验室 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a836901af14b9c0e7b1da58","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 10 * 103 Hz do 29 * 106 Hz","parameters":[{"name":"Zakres","range":"(0,01 – 200) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 10 * 103 Hz do 29 * 106 Hz\nZakres (0,01 – 200) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola magnetycznego w zakresie częstotliwości: od 10 * 103 Hz do 29 * 106 Hz\nZakres (0,01 – 200) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pole elektromagnetyczne Natezenie pola magnetycznego w zakresie czestotliwosci: od 10 * 103 Hz do 29 * 106 Hz\nZakres (0,01 – 200) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Magnetic field strength in the frequency range: from 10 * 103 Hz to 29 * 106 Hz","parameters_en":[{"name":"Range","range":"(0,01 – 200) A/m"}],"search_en":"Workplace environment - electromagnetic field Magnetic field strength in the frequency range: from 10 * 103 Hz to 29 * 106 Hz Direct measurement method Environmental Testing Laboratory Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"范围","range":"(0,01 – 200) A/m"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 环境检测实验室 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a836901af14b9c0e7b1da59","lab_id":"69ad52a3de79e566650fb207","country":"PL","accr_number":"AB 408","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Indukcja magnetyczna w zakresie częstotliwości:","parameters":[{"name":"0 Hz"},{"name":"Zakres","range":"0,1 mT – 1T"},{"name":"10Hz – 500 * 103 Hz"},{"name":"Zakres","range":"1 μT – 20 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości:\nZakres:\n0 Hz\nZakres 0,1 mT – 1T\n10Hz – 500 * 103 Hz\nZakres 1 μT – 20 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Laboratorium Badań Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Indukcja magnetyczna w zakresie częstotliwości:\nZakres:\n0 Hz\nZakres 0,1 mT – 1T\n10Hz – 500 * 103 Hz\nZakres 1 μT – 20 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pole elektromagnetyczne Indukcja magnetyczna w zakresie czestotliwosci:\nZakres:\n0 Hz\nZakres 0,1 mT – 1T\n10Hz – 500 * 103 Hz\nZakres 1 μT – 20 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Testing Laboratory","methodology_en":"Magnetic flux density in the frequency range:","parameters_en":[{"name":"0 Hz"},{"name":"Range","range":"0,1 mT – 1T"},{"name":"10Hz – 500 * 103 Hz"},{"name":"Range","range":"1 μT – 20 mT"}],"search_en":"Workplace environment - electromagnetic field Magnetic flux density in the frequency range: Direct measurement method Environmental Testing Laboratory 0 Hz Range 10Hz – 500 * 103 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"0 Hz"},{"name":"范围","range":"0,1 mT – 1T"},{"name":"10Hz – 500 * 103 Hz"},{"name":"范围","range":"1 μT – 20 mT"}],"search_zh":"工作场所环境 — 电磁场 下列频率范围内的磁感应强度： 直接测量法 环境检测实验室 范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","lab_section_zh":"环境检测实验室","test_object_zh":"工作场所环境 — 电磁场","methodology_zh":"下列频率范围内的磁感应强度："}],"has_pdf":true}