SIEĆ BADAWCZA ŁUKASIEWICZ - is a laboratory accredited by PCA under number AB 388 (Łódź, Poland). Its accreditation scope covers 9 test methods in the following areas: Materials & polymers, Microbiology, Environment. Test objects include: Polymer materials and textile products, Paper, board, packaging and packaging materials made of paper and/o…, Textile products, Fibres and textile products. Most frequently used techniques: Plate method (pour plate), Plate method (pour plate); Gravimetric method, Absorption method.
At a glance
- Accreditation number: PCA AB 388
- Methods in scope: 9
- Types of test objects: 5
- Techniques used: 5
- City: Łódź, Poland
- Accreditation number
- AB 388
- Accreditation body
- PCA
- Address
- ŁÓDZKI INSTYTUT TECHNOLOGICZNY, ul. Marii Skłodowskiej-Curie 19/27, 90-570 Łódź, LABORATORIUM BIODEGRADACJI I BADAŃ MIKROBIOLOGICZNYCH, ul. Marii Skłodowskiej-Curie 19/27
- City
- Łódź, Poland
What this laboratory tests (5)
- Polymer materials and textile products — 3 methods
- Paper, board, packaging and packaging materials made of paper and/or board — 2 methods
- Textile products — 2 methods
- Fibres and textile products — 1 method
- Textile products and polymer materials, military equipment — 1 method
Analytical techniques used (5)
- Plate method (pour plate) — 3 methods
- Plate method (pour plate); Gravimetric method — 2 methods
- Absorption method — 1 method
- Diffusion method — 1 method
- Method B2 — 1 method
Laboratory locations
- LABORATORIUM BIODEGRADACJI I BADAŃ MIKROBIOLOGICZNYCH — ul. Marii Skłodowskiej-Curie 19/27
Accreditation scope — test methods (9)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Biodegradation and Microbiological Testing Laboratory | |||||
| 1 | Polymer materials and textile products | Aerobic biodegradation in compost Range 0 – 100 % |
Plate method (pour plate); Gravimetric method | PB nr 2 wydanie I z dnia 20.04.2023 | |
| 2 | Polymer materials and textile products | Aerobic biodegradation in soil Range 0 – 100 % |
Plate method (pour plate); Gravimetric method | PB nr 3 wydanie I z dnia 20.04.2023 | |
| 3 | Polymer materials and textile products | Total microorganism count | Plate method (pour plate) | PB nr 5 wydanie I z dnia 20.04.2023 | |
| 4 | Fibres and textile products | Antibacterial activity | Absorption method | PN-EN ISO 20743:2021-12 | |
| 5 | Textile products | Antifungal activity, Agar diffusion test | Method B2 | PN-EN 14119:2005 | |
| 6 | Textile products | Determination of antibacterial activity | Diffusion method | PN-EN ISO 20645:2006 | |
| 7 | Textile products and polymer materials, military equipment | Resistance to the action of mould fungi Range 0 – 5 Testing of mould growth in a humid atmosphere |
NO-06-A107:2021 p.4.14, p.5.17 | ||
| 8 | Paper, board, packaging and packaging materials made of paper and/or board | Count of bacteria and spores | Plate method (pour plate) | ISO 8784 -1:2014 | |
| 9 | Paper, board, packaging and packaging materials made of paper and/or board | Yeast and mould count. | Plate method (pour plate) | ISO 8784 – 3:2022 | |
Reference standards (9)
ISO 8784 -1:2014
ISO 8784 – 3:2022
NO-06-A107:2021 p.4.14, p.5.17
PB nr 2 wydanie I z dnia 20.04.2023
PB nr 3 wydanie I z dnia 20.04.2023
PB nr 5 wydanie I z dnia 20.04.2023
PN-EN 14119:2005
PN-EN ISO 20645:2006
PN-EN ISO 20743:2021-12