{"lab":{"_id":"69ad52a3de79e566650fb1f5","accr_number":"AB 388","country":"PL","accr_body":"PCA","address":"ŁÓDZKI INSTYTUT TECHNOLOGICZNY, ul. Marii Skłodowskiej-Curie 19/27, 90-570 Łódź, LABORATORIUM BIODEGRADACJI I BADAŃ MIKROBIOLOGICZNYCH, ul. Marii Skłodowskiej-Curie 19/27","categories":["materials","microbiology","environment"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ -","parse_status":"parsed","parse_version":3,"pdf_files":["AB_388.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - łódzki instytut technologiczny, ul. marii skłodowskiej-curie 19/27, 90-570 łódź, laboratorium biodegradacji i badań mikrobiologicznych, ul. marii skłodowskiej-curie 19/27 materials environment other microbiology","status":"active","updated_at":"2026-03-08T14:51:13.337Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:05:57.594Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20388,podmiot.html","fields_of_testing":[{"codes":"K/15; K/17; K/18; K/21; K/23; K49","pl":"Badania mikrobiologiczne tekstyliów, tkanin, przędzy, wyciągu z materiałów polimerowych, papieru, tektury, materiałów opakowaniowych, opakowań, wyrobów z tworzyw sztucznych i gumy, wyposażenia wojskowego, wyrobów innych","en":"Microbiological tests of textiles, fabrics, yarns, soil, compost, extract from soil and compost, polymeric materials, paper, cardboard, packaging materials, packaging, plastic and rubber products, military equipment, other products"},{"codes":"C/17; C/18; C/21; C/23; C/44; C/49; C/56","pl":"Badania chemiczne tekstyliów, tkanin, przędzy, wyciągu z materiałów polimerowych, papieru, tektury, materiałów opakowaniowych, opakowań, wyrobów z tworzyw sztucznych i gumy, środków wspomagających uprawę roślin, środków ochrony roślin, wyrobów innych","en":"Chemical tests of textiles, fabrics, yarns, soil, compost, extract from soil and compost, polymeric materials, paper, cardboard, packaging materials, packaging, plastic and rubber products, plant growth substances, plant protection products, other products"}],"issue":{"no":"30","date":"22.07.2026"},"parse_date":"2026-08-13T08:05:57.594Z","parse_source":"agent-claude-code","map_coord":[51.76252,19.443207],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BIODEGRADACJI I BADAŃ MIKROBIOLOGICZNYCH","address":"ul. Marii Skłodowskiej-Curie 19/27","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/b35baa1d227e39ae757e8493ee440084/AB%20388.pdf","has_en":true,"category_counts":{"materials":6,"other":3,"microbiology":2,"environment":2},"category_scores":{"materials":2.77,"other":0.69,"microbiology":0.31,"environment":0.31},"has_zh":true},"methods":[{"_id":"6a7d7ae50636ba417e41ba5e","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Materiały polimerowe i wyroby włókiennicze","methodology":"Biodegradacja tlenowa w środowisku kompostowym","parameters":[{"name":"Zakres","range":"0 – 100 %"}],"technique":"Metoda płytkowa (posiew wgłębny); Metoda wagowa","techniques":["Metoda płytkowa (posiew wgłębny)","Metoda wagowa"],"computed":[],"activity":"Biodegradacja tlenowa w środowisku kompostowym\nZakres 0 – 100 %\nMetoda płytkowa (posiew wgłębny); Metoda wagowa","reference":"PB nr 2 wydanie I z dnia 20.04.2023","norm_bases":["PB nr 2 wydanie I z dnia 20.04.2023"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały polimerowe i wyroby włókiennicze Biodegradacja tlenowa w środowisku kompostowym\nZakres 0 – 100 %\nMetoda płytkowa (posiew wgłębny); Metoda wagowa PB nr 2 wydanie I z dnia 20.04.2023 Materialy polimerowe i wyroby wlokiennicze Biodegradacja tlenowa w srodowisku kompostowym\nZakres 0 – 100 %\nMetoda plytkowa (posiew wglebny); Metoda wagowa PB nr 2 wydanie I z dnia 20.04.2023","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Aerobic biodegradation in compost","parameters_en":[{"name":"Range","range":"0 – 100 %"}],"search_en":"Polymer materials and textile products Aerobic biodegradation in compost Plate method (pour plate); Gravimetric method Biodegradation and Microbiological Testing Laboratory Range PB nr 2 wydanie I z dnia 20.04.2023","technique_en":"Plate method (pour plate); Gravimetric method","test_object_en":"Polymer materials and textile products","parameters_zh":[{"name":"范围","range":"0 – 100 %"}],"search_zh":"生物降解与微生物检验实验室 范围 PB nr 2 wydanie I z dnia 20.04.2023","lab_section_zh":"生物降解与微生物检验实验室"},{"_id":"6a7d7ae50636ba417e41ba5f","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Materiały polimerowe i wyroby włókiennicze","methodology":"Biodegradacja tlenowa w środowisku glebowym","parameters":[{"name":"Zakres","range":"0 – 100 %"}],"technique":"Metoda płytkowa (posiew wgłębny); Metoda wagowa","techniques":["Metoda płytkowa (posiew wgłębny)","Metoda wagowa"],"computed":[],"activity":"Biodegradacja tlenowa w środowisku glebowym\nZakres 0 – 100 %\nMetoda płytkowa (posiew wgłębny); Metoda wagowa","reference":"PB nr 3 wydanie I z dnia 20.04.2023","norm_bases":["PB nr 3 wydanie I z dnia 20.04.2023"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały polimerowe i wyroby włókiennicze Biodegradacja tlenowa w środowisku glebowym\nZakres 0 – 100 %\nMetoda płytkowa (posiew wgłębny); Metoda wagowa PB nr 3 wydanie I z dnia 20.04.2023 Materialy polimerowe i wyroby wlokiennicze Biodegradacja tlenowa w srodowisku glebowym\nZakres 0 – 100 %\nMetoda plytkowa (posiew wglebny); Metoda wagowa PB nr 3 wydanie I z dnia 20.04.2023","categories":["materials","environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Aerobic biodegradation in soil","parameters_en":[{"name":"Range","range":"0 – 100 %"}],"search_en":"Polymer materials and textile products Aerobic biodegradation in soil Plate method (pour plate); Gravimetric method Biodegradation and Microbiological Testing Laboratory Range PB nr 3 wydanie I z dnia 20.04.2023","technique_en":"Plate method (pour plate); Gravimetric method","test_object_en":"Polymer materials and textile products","parameters_zh":[{"name":"范围","range":"0 – 100 %"}],"search_zh":"生物降解与微生物检验实验室 范围 PB nr 3 wydanie I z dnia 20.04.2023","lab_section_zh":"生物降解与微生物检验实验室"},{"_id":"6a7d7ae50636ba417e41ba60","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Materiały polimerowe i wyroby włókiennicze","methodology":"Ogólna liczba mikroorganizmów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów\nMetoda płytkowa (posiew wgłębny)","reference":"PB nr 5 wydanie I z dnia 20.04.2023","norm_bases":["PB nr 5 wydanie I z dnia 20.04.2023"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały polimerowe i wyroby włókiennicze Ogólna liczba mikroorganizmów\nMetoda płytkowa (posiew wgłębny) PB nr 5 wydanie I z dnia 20.04.2023 Materialy polimerowe i wyroby wlokiennicze Ogolna liczba mikroorganizmow\nMetoda plytkowa (posiew wglebny) PB nr 5 wydanie I z dnia 20.04.2023","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Total microorganism count","search_en":"Polymer materials and textile products Total microorganism count Plate method (pour plate) Biodegradation and Microbiological Testing Laboratory PB nr 5 wydanie I z dnia 20.04.2023","technique_en":"Plate method (pour plate)","test_object_en":"Polymer materials and textile products","search_zh":"微生物总数 平板法（倾注培养） 生物降解与微生物检验实验室 PB nr 5 wydanie I z dnia 20.04.2023","technique_zh":"平板法（倾注培养）","lab_section_zh":"生物降解与微生物检验实验室","methodology_zh":"微生物总数"},{"_id":"6a7d7ae50636ba417e41ba61","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Włókna i wyroby włókiennicze","methodology":"Aktywność antybakteryjna","parameters":[],"technique":"Metoda absorpcyjna","techniques":["Metoda absorpcyjna"],"computed":[],"activity":"Aktywność antybakteryjna\nMetoda absorpcyjna","reference":"PN-EN ISO 20743:2021-12","norm_bases":["PN-EN ISO 20743:2021-12"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włókna i wyroby włókiennicze Aktywność antybakteryjna\nMetoda absorpcyjna PN-EN ISO 20743:2021-12 Wlokna i wyroby wlokiennicze Aktywnosc antybakteryjna\nMetoda absorpcyjna PN-EN ISO 20743:2021-12","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Antibacterial activity","search_en":"Fibres and textile products Antibacterial activity Absorption method Biodegradation and Microbiological Testing Laboratory PN-EN ISO 20743:2021-12","technique_en":"Absorption method","test_object_en":"Fibres and textile products","lab_section_zh":"生物降解与微生物检验实验室","search_zh":"生物降解与微生物检验实验室 PN-EN ISO 20743:2021-12"},{"_id":"6a7d7ae50636ba417e41ba62","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Wyroby włókiennicze","methodology":"Aktywność przeciwgrzybiczna, Test dyfuzyjny na agarze","parameters":[],"technique":"Metoda B2","techniques":["Metoda B2"],"computed":[],"activity":"Aktywność przeciwgrzybiczna, Test dyfuzyjny na agarze\nMetoda B2","reference":"PN-EN 14119:2005","norm_bases":["PN-EN 14119:2005"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby włókiennicze Aktywność przeciwgrzybiczna, Test dyfuzyjny na agarze\nMetoda B2 PN-EN 14119:2005 Wyroby wlokiennicze Aktywnosc przeciwgrzybiczna, Test dyfuzyjny na agarze\nMetoda B2 PN-EN 14119:2005","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Antifungal activity, Agar diffusion test","search_en":"Textile products Antifungal activity, Agar diffusion test Method B2 Biodegradation and Microbiological Testing Laboratory PN-EN 14119:2005","technique_en":"Method B2","test_object_en":"Textile products","search_zh":"纺织制品 生物降解与微生物检验实验室 PN-EN 14119:2005","test_object_zh":"纺织制品","lab_section_zh":"生物降解与微生物检验实验室"},{"_id":"6a7d7ae50636ba417e41ba63","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Wyroby włókiennicze","methodology":"Wyznaczanie aktywności antybakteryjnej","parameters":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"computed":[],"activity":"Wyznaczanie aktywności antybakteryjnej\nMetoda dyfuzyjna","reference":"PN-EN ISO 20645:2006","norm_bases":["PN-EN ISO 20645:2006"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby włókiennicze Wyznaczanie aktywności antybakteryjnej\nMetoda dyfuzyjna PN-EN ISO 20645:2006 Wyroby wlokiennicze Wyznaczanie aktywnosci antybakteryjnej\nMetoda dyfuzyjna PN-EN ISO 20645:2006","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Determination of antibacterial activity","search_en":"Textile products Determination of antibacterial activity Diffusion method Biodegradation and Microbiological Testing Laboratory PN-EN ISO 20645:2006","technique_en":"Diffusion method","test_object_en":"Textile products","search_zh":"纺织制品 扩散法 生物降解与微生物检验实验室 PN-EN ISO 20645:2006","technique_zh":"扩散法","test_object_zh":"纺织制品","lab_section_zh":"生物降解与微生物检验实验室"},{"_id":"6a7d7ae50636ba417e41ba64","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Wyroby włókiennicze i materiały polimerowe, wyposażenie wojskowe","methodology":"Odporność na oddziaływanie grzybów pleśniowych","parameters":[{"name":"Zakres","range":"0 – 5"},{"name":"Badanie rozwoju grzybów w wilgotnej atmosferze"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na oddziaływanie grzybów pleśniowych\nZakres:\nZakres 0 – 5\nBadanie rozwoju grzybów w wilgotnej atmosferze","reference":"NO-06-A107:2021 p.4.14, p.5.17","norm_bases":["NO-06-A107:2021 p.4.14, p.5.17"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby włókiennicze i materiały polimerowe, wyposażenie wojskowe Odporność na oddziaływanie grzybów pleśniowych\nZakres:\nZakres 0 – 5\nBadanie rozwoju grzybów w wilgotnej atmosferze NO-06-A107:2021 p.4.14, p.5.17 Wyroby wlokiennicze i materialy polimerowe, wyposazenie wojskowe Odpornosc na oddzialywanie grzybow plesniowych\nZakres:\nZakres 0 – 5\nBadanie rozwoju grzybow w wilgotnej atmosferze NO-06-A107:2021 p.4.14, p.5.17","categories":["materials","microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Resistance to the action of mould fungi","parameters_en":[{"name":"Range","range":"0 – 5"},{"name":"Testing of mould growth in a humid atmosphere"}],"search_en":"Textile products and polymer materials, military equipment Resistance to the action of mould fungi Biodegradation and Microbiological Testing Laboratory Range Testing of mould growth in a humid atmosphere NO-06-A107:2021 p.4.14, p.5.17","test_object_en":"Textile products and polymer materials, military equipment","parameters_zh":[{"name":"范围","range":"0 – 5"},{"name":"Badanie rozwoju grzybów w wilgotnej atmosferze"}],"search_zh":"生物降解与微生物检验实验室 范围 NO-06-A107:2021 p.4.14, p.5.17","lab_section_zh":"生物降解与微生物检验实验室"},{"_id":"6a7d7ae50636ba417e41ba65","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Papier, tektura, opakowania i materiały opakowaniowe z papieru i/lub tektury","methodology":"Liczba bakterii i przetrwalników","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii i przetrwalników\nMetoda płytkowa (posiew wgłębny)","reference":"ISO 8784 -1:2014","norm_bases":["ISO 8784 -1:2014"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier, tektura, opakowania i materiały opakowaniowe z papieru i/lub tektury Liczba bakterii i przetrwalników\nMetoda płytkowa (posiew wgłębny) ISO 8784 -1:2014 Papier, tektura, opakowania i materialy opakowaniowe z papieru i/lub tektury Liczba bakterii i przetrwalnikow\nMetoda plytkowa (posiew wglebny) ISO 8784 -1:2014","categories":["materials","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Count of bacteria and spores","search_en":"Paper, board, packaging and packaging materials made of paper and/or board Count of bacteria and spores Plate method (pour plate) Biodegradation and Microbiological Testing Laboratory ISO 8784 -1:2014","technique_en":"Plate method (pour plate)","test_object_en":"Paper, board, packaging and packaging materials made of paper and/or board","search_zh":"平板法（倾注培养） 生物降解与微生物检验实验室 ISO 8784 -1:2014","technique_zh":"平板法（倾注培养）","lab_section_zh":"生物降解与微生物检验实验室"},{"_id":"6a7d7ae50636ba417e41ba66","lab_id":"69ad52a3de79e566650fb1f5","country":"PL","accr_number":"AB 388","accr_body":"PCA","test_object":"Papier, tektura, opakowania i materiały opakowaniowe z papieru i/lub tektury","methodology":"Liczba drożdży i pleśni.","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni.\nMetoda płytkowa (posiew wgłębny)","reference":"ISO 8784 – 3:2022","norm_bases":["ISO 8784 – 3:2022"],"lab_section":"Laboratorium Biodegradacji i Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier, tektura, opakowania i materiały opakowaniowe z papieru i/lub tektury Liczba drożdży i pleśni.\nMetoda płytkowa (posiew wgłębny) ISO 8784 – 3:2022 Papier, tektura, opakowania i materialy opakowaniowe z papieru i/lub tektury Liczba drozdzy i plesni.\nMetoda plytkowa (posiew wglebny) ISO 8784 – 3:2022","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Biodegradation and Microbiological Testing Laboratory","methodology_en":"Yeast and mould count.","search_en":"Paper, board, packaging and packaging materials made of paper and/or board Yeast and mould count. Plate method (pour plate) Biodegradation and Microbiological Testing Laboratory ISO 8784 – 3:2022","technique_en":"Plate method (pour plate)","test_object_en":"Paper, board, packaging and packaging materials made of paper and/or board","search_zh":"平板法（倾注培养） 生物降解与微生物检验实验室 ISO 8784 – 3:2022","technique_zh":"平板法（倾注培养）","lab_section_zh":"生物降解与微生物检验实验室"}],"has_pdf":true}