🇵🇱 WOJSKOWY INSTYTUT HIGIENY I EPIDEMIOLOGII PL
EnvironmentElectronics & EMCAutomotive
WOJSKOWY INSTYTUT HIGIENY I EPIDEMIOLOGII is a laboratory accredited by PCA under number AB 366 (Warszawa, Poland). Its accreditation scope covers 28 test methods in the following areas: Environment, Electronics & EMC, Automotive. Test objects include: Environment – electromagnetic field in the vicinity of radar and ra…, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field in the workspace from…, Workplace environment - electromagnetic field in the workspace from…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 366
- Methods in scope: 28
- Types of test objects: 8
- Techniques used: 1
- City: Warszawa, Poland
- Accreditation number
- AB 366
- Accreditation body
- PCA
- Address
- im. gen. Karola Kaczkowskiego, ZESPÓŁ ANALIZ ZAGROŻEŃ ELEKTROMAGNETYCZNYCH, ul. Kozielska 4
- City
- Warszawa, Poland
What this laboratory tests (8)
- Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) — 7 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 3 methods
- Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices — 3 methods
- Workplace environment - electromagnetic field in the workspace from measurement and control apparatus — 3 methods
- Workplace environment - electromagnetic field in the workspace from stationary communication equipment — 3 methods
- Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment — 3 methods
- Workplace environment - electromagnetic field in the workspace originating from missile guidance stations — 3 methods
- Workplace environment - electromagnetic field in the workspace originating from radar equipment — 3 methods
Analytical techniques used (1)
- Direct measurement method — 19 methods
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - electromagnetic field in the workspace originating from radar equipment | Electric field strength: in the frequency range from 100 MHz do 16 GHz Range (0,5 - 8000) V/m in the frequency range from 16 GHz do 60 GHz Range (0,5 - 1000) V/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 2 | Workplace environment - electromagnetic field in the workspace originating from radar equipment | Magnetic field strength: in the frequency range from 100 MHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 3 | Workplace environment - electromagnetic field in the workspace originating from radar equipment | Magnetic field strength: in the frequency range from 0,1 GHz do 60 GHz (calculated) |
NO-06-A215-2:2022 | ||
| 4 | Workplace environment - electromagnetic field in the workspace originating from missile guidance stations | Electric field strength: in the frequency range from 100 MHz do 16 GHz Range (0,5 - 8000) V/m in the frequency range from 16 GHz do 60 GHz Range (0,5 – 1000) V/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 5 | Workplace environment - electromagnetic field in the workspace originating from missile guidance stations | Magnetic field strength: in the frequency range from 100 MHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 6 | Workplace environment - electromagnetic field in the workspace originating from missile guidance stations | Magnetic field strength: in the frequency range from 0,1 GHz do 60 GHz (calculated) |
NO-06-A215-2:2022 | ||
| 7 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Electric field strength: in the frequency range from 2,5 kHz do 60 GHz Range (0,5 – 1000) V/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 8 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength: in the frequency range from 2,5 kHz do 400 kHz Range (0,25 – 24000) A/m in the frequency range from 100 kHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 9 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength: in the frequency range from 0,8 GHz do 60 GHz (calculated) |
NO-06-A215-2:2022 | ||
| 10 | Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment | Electric field strength: in the frequency range from 100 kHz do 60 GHz Range (0,5 – 1000) V/m Direct measurement method |
NO-06-A215-2:2022 | ||
| 11 | Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment | Magnetic field strength: in the frequency range from 100 kHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 12 | Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment | Magnetic field strength: in the frequency range from 0,8 GHz do 60 GHz (calculated) |
NO-06-A215-2:2022 | ||
| 13 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Electric field strength: in the frequency range from 1,6 MHz do 3 GHz Range (0,5 – 1000) V/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 14 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength: in the frequency range from 1,6 MHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 15 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength: in the frequency range from 0,8 GHz do 3 GHz (calculated) |
NO-06-A215-2:2022 | ||
| 16 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Electric field strength: in the frequency range from 2,5 kHz do 60 GHz Range (0,5 – 1000) V/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 17 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength: in the frequency range from 8 Hz do 400 kHz Range (0,25 – 24000) A/m in the frequency range from 100 kHz do 1 GHz Range (0,01 – 10) A/m with a frequency of 0 Hz Range (40 – 800 000) A/m |
Direct measurement method | NO-06-A215-2:2022 | |
| 18 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength: in the frequency range from 0,8 GHz do 60 GHz (calculated) |
NO-06-A215-2:2022 | ||
| 19 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range from 2,5 kHz do 100 kHz Range (3 – 1000) V/m in the frequency range from 100 kHz do 60 GHz Range (0,5 – 1000) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 20 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range from 2,5 kHz do 400 kHz Range (0,25 – 24000) A/m in the frequency range from 100 kHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 21 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz do 60 GHz (calculated) |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 22 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 150 MHz do 9,2 GHz R.m.s. value range: (1,6 – 400) V/m Peak value range: (5 – 5600) V/m for the fill factor ti/Tp (0,005 – 0,1) |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 23 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 150 MHz do 9,2 GHz R.m.s. value range: (0,4 – 400) V/m Peak value range: (5 – 5600) V/m for duty cycle ti/Tp < 0,005 |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 24 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 9,2 GHz do 15,6 GHz R.m.s. value range: (5,7 – 400) V/m Peak value range: (40 – 5600) V/m for the fill factor ti/Tp (0,005 – 0,02) |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 25 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 9,2 GHz do 15,6 GHz R.m.s. value range: (2,8 – 400) V/m Peak value range: (40 – 5600) V/m for duty cycle ti/Tp: < 0,005 |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 26 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 150 MHz do 60 GHz R.m.s. value range: (0,7 – 1000) V/m for duty cycle ti/Tp = 1 |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 27 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 100 kHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 28 | Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 150 MHz do 15,6 GHz (calculated) |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
Reference standards (3)
NO-06-A215-2:2022
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)