{"lab":{"_id":"69ad52a3de79e566650fb1db","accr_number":"AB 366","country":"PL","accr_body":"PCA","address":"im. gen. Karola Kaczkowskiego, ZESPÓŁ ANALIZ ZAGROŻEŃ ELEKTROMAGNETYCZNYCH, ul. Kozielska 4","categories":["environment","automotive"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"WOJSKOWY INSTYTUT HIGIENY I EPIDEMIOLOGII","parse_status":"parsed","parse_version":2,"pdf_files":["AB_366.pdf"],"scope_summary":"","search_text":"wojskowy instytut higieny i epidemiologii im. gen. karola kaczkowskiego, zespół analiz zagrożeń elektromagnetycznych, ul. kozielska 4 other environment metrology pharma electronics automotive","status":"active","updated_at":"2026-03-08T14:51:11.913Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:11.913Z","email_confidence":"high","email_mx":true,"email_source":"https://wihe.pl/kontakt","fields_of_testing":[{"codes":"G/33, G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne), środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field), general environment (physical factors - electromagnetic field)"}],"issue":{"no":"20","date":"12.09.2025"},"parse_date":"2026-07-20T07:09:34.993Z","parse_source":"script-pdfplumber","map_coord":[52.253274,20.961949],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":28,"automotive":3},"category_scores":{"environment":25.29,"automotive":0.29},"has_zh":true},"methods":[{"_id":"6a5dc9aef1c10c8ce825b076","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 MHz","range":"do 16 GHz"},{"name":"Zakres","range":"(0,5 - 8000) V/m"},{"name":"w zakresie częstotliwości od 16 GHz","range":"do 60 GHz"},{"name":"Zakres","range":"(0,5 - 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 100 MHz","range":"do 16 GHz"},{"name":"Range","range":"(0,5 - 8000) V/m"},{"name":"in the frequency range from 16 GHz","range":"do 60 GHz"},{"name":"Range","range":"(0,5 - 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 16 GHz\nZakres (0,5 - 8000) V/m\nw zakresie częstotliwości od 16 GHz do 60 GHz\nZakres (0,5 - 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 16 GHz\nZakres (0,5 - 8000) V/m\nw zakresie częstotliwości od 16 GHz do 60 GHz\nZakres (0,5 - 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen radiolokacyjnych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 100 MHz do 16 GHz\nZakres (0,5 - 8000) V/m\nw zakresie czestotliwosci od 16 GHz do 60 GHz\nZakres (0,5 - 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment Electric field strength: Direct measurement method in the frequency range from 100 MHz Range in the frequency range from 16 GHz Range NO-06-A215-2:2022","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 100 MHz 起","range":"do 16 GHz"},{"name":"范围","range":"(0,5 - 8000) V/m"},{"name":"w zakresie częstotliwości od 16 GHz","range":"do 60 GHz"},{"name":"范围","range":"(0,5 - 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场 电场强度： 直接测量法 频率范围自 100 MHz 起 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b077","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 100 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen radiolokacyjnych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment Magnetic field strength: Direct measurement method in the frequency range from 100 MHz Range NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场 磁场强度： 直接测量法 频率范围自 100 MHz 起 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b078","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,1 GHz","range":"do 60 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,1 GHz","range":"do 60 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 GHz do 60 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń radiolokacyjnych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 GHz do 60 GHz\n(z obliczeń) NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen radiolokacyjnych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 GHz do 60 GHz\n(z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace originating from radar equipment Magnetic field strength: in the frequency range from 0,1 GHz (calculated) NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 0,1 GHz","range":"do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场 磁场强度： （计算得出） NO-06-A215-2:2022","test_object_zh":"工作环境 － 作业空间内由雷达设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b079","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 MHz","range":"do 16 GHz"},{"name":"Zakres","range":"(0,5 - 8000) V/m"},{"name":"w zakresie częstotliwości od 16 GHz","range":"do 60 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 100 MHz","range":"do 16 GHz"},{"name":"Range","range":"(0,5 - 8000) V/m"},{"name":"in the frequency range from 16 GHz","range":"do 60 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 16 GHz\nZakres (0,5 - 8000) V/m\nw zakresie częstotliwości od 16 GHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 16 GHz\nZakres (0,5 - 8000) V/m\nw zakresie częstotliwości od 16 GHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacji naprowadzania rakiet Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 100 MHz do 16 GHz\nZakres (0,5 - 8000) V/m\nw zakresie czestotliwosci od 16 GHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Electric field strength: Direct measurement method in the frequency range from 100 MHz Range in the frequency range from 16 GHz Range NO-06-A215-2:2022","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 100 MHz 起","range":"do 16 GHz"},{"name":"范围","range":"(0,5 - 8000) V/m"},{"name":"w zakresie częstotliwości od 16 GHz","range":"do 60 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场 电场强度： 直接测量法 频率范围自 100 MHz 起 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b07a","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 100 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacji naprowadzania rakiet Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Magnetic field strength: Direct measurement method in the frequency range from 100 MHz Range NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场 磁场强度： 直接测量法 频率范围自 100 MHz 起 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b07b","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet","test_object_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,1 GHz","range":"do 60 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,1 GHz","range":"do 60 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 GHz do 60 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacji naprowadzania rakiet Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,1 GHz do 60 GHz\n(z obliczeń) NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacji naprowadzania rakiet Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 GHz do 60 GHz\n(z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Magnetic field strength: in the frequency range from 0,1 GHz (calculated) NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 0,1 GHz","range":"do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场 磁场强度： （计算得出） NO-06-A215-2:2022","test_object_zh":"工作环境 － 作业空间内由导弹制导站产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b07c","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 2,5 kHz","range":"do 60 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 2,5 kHz","range":"do 60 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 2,5 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: Direct measurement method in the frequency range from 2,5 kHz Range NO-06-A215-2:2022","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 2,5 kHz 起","range":"do 60 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 电场强度： 直接测量法 频率范围自 2,5 kHz 起 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b07d","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 2,5 kHz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,25 – 24000) A/m"},{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 2,5 kHz","range":"do 400 kHz"},{"name":"Range","range":"(0,25 – 24000) A/m"},{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 2,5 kHz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: Direct measurement method in the frequency range from 2,5 kHz Range in the frequency range from 100 kHz Range NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 2,5 kHz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,25 – 24000) A/m"},{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度： 直接测量法 频率范围自 2,5 kHz 起 范围 频率范围自 100 kHz 起 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b07e","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 60 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 60 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 60 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 60 GHz\n(z obliczeń) NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 60 GHz\n(z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: in the frequency range from 0,8 GHz (calculated) NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度： 频率范围自 0,8 GHz 起 （计算得出） NO-06-A215-2:2022","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b07f","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od: - mobilnych urządzeń łączności - pojazdów ze środkami łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 60 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"Metoda pomiarowa bezpośrednia"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 60 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"Direct measurement method"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od: - mobilnych urządzeń łączności - pojazdów ze środkami łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od: - mobilnych urzadzen lacznosci - pojazdow ze srodkami lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment","automotive"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment Electric field strength: in the frequency range from 100 kHz Range Direct measurement method NO-06-A215-2:2022","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 60 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"直接测量法"}],"search_zh":"电场强度： 频率范围自 100 kHz 起 范围 直接测量法 NO-06-A215-2:2022"},{"_id":"6a5dc9aef1c10c8ce825b080","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od: - mobilnych urządzeń łączności - pojazdów ze środkami łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od: - mobilnych urządzeń łączności - pojazdów ze środkami łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od: - mobilnych urzadzen lacznosci - pojazdow ze srodkami lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment","automotive"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 NO-06-A215-2:2022","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b081","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od: - mobilnych urządzeń łączności - pojazdów ze środkami łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 60 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 60 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 60 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od: - mobilnych urządzeń łączności - pojazdów ze środkami łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 60 GHz\n(z obliczeń) NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od: - mobilnych urzadzen lacznosci - pojazdow ze srodkami lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 60 GHz\n(z obliczen) NO-06-A215-2:2022","categories":["environment","automotive"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from: - mobile communication devices - vehicles with communication equipment Magnetic field strength: in the frequency range from 0,8 GHz (calculated) NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 0,8 GHz 起 （计算得出） NO-06-A215-2:2022"},{"_id":"6a5dc9aef1c10c8ce825b082","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 1,6 MHz","range":"do 3 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 1,6 MHz","range":"do 3 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 1,6 MHz do 3 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 1,6 MHz do 3 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 1,6 MHz do 3 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength: Direct measurement method in the frequency range from 1,6 MHz Range NO-06-A215-2:2022","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 1,6 MHz","range":"do 3 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场 电场强度： 直接测量法 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b083","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 1,6 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 1,6 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1,6 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1,6 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1,6 MHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: Direct measurement method in the frequency range from 1,6 MHz Range NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 1,6 MHz","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场 磁场强度： 直接测量法 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b084","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 3 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 3 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 3 GHz\n(z obliczeń) NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 3 GHz\n(z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: in the frequency range from 0,8 GHz (calculated) NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场 磁场强度： 频率范围自 0,8 GHz 起 （计算得出） NO-06-A215-2:2022","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b085","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej","test_object_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 2,5 kHz","range":"do 60 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 2,5 kHz","range":"do 60 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 2,5 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength: Direct measurement method in the frequency range from 2,5 kHz Range NO-06-A215-2:2022","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 2,5 kHz 起","range":"do 60 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场 电场强度： 直接测量法 频率范围自 2,5 kHz 起 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b086","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej","test_object_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 8 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,25 – 24000) A/m"},{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"},{"name":"o częstotliwości 0 Hz"},{"name":"Zakres","range":"(40 – 800 000) A/m"}],"parameters_en":[{"name":"in the frequency range from 8 Hz","range":"do 400 kHz"},{"name":"Range","range":"(0,25 – 24000) A/m"},{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"},{"name":"with a frequency of 0 Hz"},{"name":"Range","range":"(40 – 800 000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 8 Hz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\no częstotliwości 0 Hz\nZakres (40 – 800 000) A/m\nMetoda pomiarowa bezpośrednia","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 8 Hz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\no częstotliwości 0 Hz\nZakres (40 – 800 000) A/m\nMetoda pomiarowa bezpośrednia NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 8 Hz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\no czestotliwosci 0 Hz\nZakres (40 – 800 000) A/m\nMetoda pomiarowa bezposrednia NO-06-A215-2:2022","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: Direct measurement method in the frequency range from 8 Hz Range in the frequency range from 100 kHz Range with a frequency of 0 Hz Range NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 8 Hz","range":"do 400 kHz"},{"name":"范围","range":"(0,25 – 24000) A/m"},{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"},{"name":"o częstotliwości 0 Hz"},{"name":"范围","range":"(40 – 800 000) A/m"}],"search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场 磁场强度： 直接测量法 范围 频率范围自 100 kHz 起 范围 范围 NO-06-A215-2:2022","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b087","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej","test_object_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 60 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 60 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 60 GHz\n(z obliczeń)","reference":"NO-06-A215-2:2022","norm_bases":["NO-06-A215-2:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 60 GHz\n(z obliczeń) NO-06-A215-2:2022 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 60 GHz\n(z obliczen) NO-06-A215-2:2022","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: in the frequency range from 0,8 GHz (calculated) NO-06-A215-2:2022","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场 磁场强度： 频率范围自 0,8 GHz 起 （计算得出） NO-06-A215-2:2022","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b088","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 2,5 kHz","range":"do 100 kHz"},{"name":"Zakres","range":"(3 – 1000) V/m"},{"name":"w zakresie częstotliwości od 100 kHz","range":"do 60 GHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"parameters_en":[{"name":"in the frequency range from 2,5 kHz","range":"do 100 kHz"},{"name":"Range","range":"(3 – 1000) V/m"},{"name":"in the frequency range from 100 kHz","range":"do 60 GHz"},{"name":"Range","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 100 kHz\nZakres (3 – 1000) V/m\nw zakresie częstotliwości od 100 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 100 kHz\nZakres (3 – 1000) V/m\nw zakresie częstotliwości od 100 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 2,5 kHz do 100 kHz\nZakres (3 – 1000) V/m\nw zakresie czestotliwosci od 100 kHz do 60 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 2,5 kHz Range in the frequency range from 100 kHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 2,5 kHz 起","range":"do 100 kHz"},{"name":"范围","range":"(3 – 1000) V/m"},{"name":"频率范围自 100 kHz 起","range":"do 60 GHz"},{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 2,5 kHz 起 范围 频率范围自 100 kHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b089","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 2,5 kHz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,25 – 24000) A/m"},{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 2,5 kHz","range":"do 400 kHz"},{"name":"Range","range":"(0,25 – 24000) A/m"},{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 2,5 kHz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 2,5 kHz do 400 kHz\nZakres (0,25 – 24000) A/m\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: Direct measurement method in the frequency range from 2,5 kHz Range in the frequency range from 100 kHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 2,5 kHz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,25 – 24000) A/m"},{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 频率范围自 2,5 kHz 起 范围 频率范围自 100 kHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b08a","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz","range":"do 60 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 10 MHz","range":"do 60 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 60 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: in the frequency range from 10 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 MHz 起","range":"do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 10 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b08b","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 150 MHz","range":"do 9,2 GHz"},{"name":"Zakres wartości skutecznej:","range":"(1,6 – 400) V/m"},{"name":"Zakres wartości szczytowej:","range":"(5 – 5600) V/m"},{"name":"dla współczynnika wypełnienia"},{"name":"ti/Tp","range":"(0,005 – 0,1)"}],"parameters_en":[{"name":"in the frequency range from 150 MHz","range":"do 9,2 GHz"},{"name":"R.m.s. value range:","range":"(1,6 – 400) V/m"},{"name":"Peak value range:","range":"(5 – 5600) V/m"},{"name":"for the fill factor"},{"name":"ti/Tp","range":"(0,005 – 0,1)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 9,2 GHz\nZakres wartości skutecznej: (1,6 – 400) V/m\nZakres wartości szczytowej: (5 – 5600) V/m\ndla współczynnika wypełnienia\nti/Tp (0,005 – 0,1)\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 9,2 GHz\nZakres wartości skutecznej: (1,6 – 400) V/m\nZakres wartości szczytowej: (5 – 5600) V/m\ndla współczynnika wypełnienia\nti/Tp (0,005 – 0,1)\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 150 MHz do 9,2 GHz\nZakres wartosci skutecznej: (1,6 – 400) V/m\nZakres wartosci szczytowej: (5 – 5600) V/m\ndla wspolczynnika wypelnienia\nti/Tp (0,005 – 0,1)\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 150 MHz R.m.s. value range: Peak value range: for the fill factor ti/Tp Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 150 MHz 起 有效值范围： 峰值范围： Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）","parameters_zh":[{"name":"频率范围自 150 MHz 起","range":"do 9,2 GHz"},{"name":"有效值范围：","range":"(1,6 – 400) V/m"},{"name":"峰值范围：","range":"(5 – 5600) V/m"},{"name":"dla współczynnika wypełnienia"},{"name":"ti/Tp","range":"(0,005 – 0,1)"}]},{"_id":"6a5dc9aef1c10c8ce825b08c","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 150 MHz","range":"do 9,2 GHz"},{"name":"Zakres wartości skutecznej:","range":"(0,4 – 400) V/m"},{"name":"Zakres wartości szczytowej:","range":"(5 – 5600) V/m"},{"name":"dla współczynnika wypełnienia ti/Tp < 0,005"}],"parameters_en":[{"name":"in the frequency range from 150 MHz","range":"do 9,2 GHz"},{"name":"R.m.s. value range:","range":"(0,4 – 400) V/m"},{"name":"Peak value range:","range":"(5 – 5600) V/m"},{"name":"for duty cycle ti/Tp < 0,005"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 9,2 GHz\nZakres wartości skutecznej: (0,4 – 400) V/m\nZakres wartości szczytowej: (5 – 5600) V/m\ndla współczynnika wypełnienia ti/Tp < 0,005\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 9,2 GHz\nZakres wartości skutecznej: (0,4 – 400) V/m\nZakres wartości szczytowej: (5 – 5600) V/m\ndla współczynnika wypełnienia ti/Tp < 0,005\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 150 MHz do 9,2 GHz\nZakres wartosci skutecznej: (0,4 – 400) V/m\nZakres wartosci szczytowej: (5 – 5600) V/m\ndla wspolczynnika wypelnienia ti/Tp < 0,005\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 150 MHz R.m.s. value range: Peak value range: for duty cycle ti/Tp < 0,005 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 150 MHz 起 有效值范围： 峰值范围： Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）","parameters_zh":[{"name":"频率范围自 150 MHz 起","range":"do 9,2 GHz"},{"name":"有效值范围：","range":"(0,4 – 400) V/m"},{"name":"峰值范围：","range":"(5 – 5600) V/m"},{"name":"dla współczynnika wypełnienia ti/Tp < 0,005"}]},{"_id":"6a5dc9aef1c10c8ce825b08d","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 9,2 GHz","range":"do 15,6 GHz"},{"name":"Zakres wartości skutecznej:","range":"(5,7 – 400) V/m"},{"name":"Zakres wartości szczytowej:","range":"(40 – 5600) V/m"},{"name":"dla współczynnika wypełnienia"},{"name":"ti/Tp","range":"(0,005 – 0,02)"}],"parameters_en":[{"name":"in the frequency range from 9,2 GHz","range":"do 15,6 GHz"},{"name":"R.m.s. value range:","range":"(5,7 – 400) V/m"},{"name":"Peak value range:","range":"(40 – 5600) V/m"},{"name":"for the fill factor"},{"name":"ti/Tp","range":"(0,005 – 0,02)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 9,2 GHz do 15,6 GHz\nZakres wartości skutecznej: (5,7 – 400) V/m\nZakres wartości szczytowej: (40 – 5600) V/m\ndla współczynnika wypełnienia\nti/Tp (0,005 – 0,02)\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 9,2 GHz do 15,6 GHz\nZakres wartości skutecznej: (5,7 – 400) V/m\nZakres wartości szczytowej: (40 – 5600) V/m\ndla współczynnika wypełnienia\nti/Tp (0,005 – 0,02)\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 9,2 GHz do 15,6 GHz\nZakres wartosci skutecznej: (5,7 – 400) V/m\nZakres wartosci szczytowej: (40 – 5600) V/m\ndla wspolczynnika wypelnienia\nti/Tp (0,005 – 0,02)\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 9,2 GHz R.m.s. value range: Peak value range: for the fill factor ti/Tp Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 有效值范围： 峰值范围： Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）","parameters_zh":[{"name":"w zakresie częstotliwości od 9,2 GHz","range":"do 15,6 GHz"},{"name":"有效值范围：","range":"(5,7 – 400) V/m"},{"name":"峰值范围：","range":"(40 – 5600) V/m"},{"name":"dla współczynnika wypełnienia"},{"name":"ti/Tp","range":"(0,005 – 0,02)"}]},{"_id":"6a5dc9aef1c10c8ce825b08e","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 9,2 GHz","range":"do 15,6 GHz"},{"name":"Zakres wartości skutecznej:","range":"(2,8 – 400) V/m"},{"name":"Zakres wartości szczytowej:","range":"(40 – 5600) V/m"},{"name":"dla współczynnika wypełnienia ti/Tp: < 0,005"}],"parameters_en":[{"name":"in the frequency range from 9,2 GHz","range":"do 15,6 GHz"},{"name":"R.m.s. value range:","range":"(2,8 – 400) V/m"},{"name":"Peak value range:","range":"(40 – 5600) V/m"},{"name":"for duty cycle ti/Tp: < 0,005"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 9,2 GHz do 15,6 GHz\nZakres wartości skutecznej: (2,8 – 400) V/m\nZakres wartości szczytowej: (40 – 5600) V/m\ndla współczynnika wypełnienia ti/Tp: < 0,005\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 9,2 GHz do 15,6 GHz\nZakres wartości skutecznej: (2,8 – 400) V/m\nZakres wartości szczytowej: (40 – 5600) V/m\ndla współczynnika wypełnienia ti/Tp: < 0,005\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 9,2 GHz do 15,6 GHz\nZakres wartosci skutecznej: (2,8 – 400) V/m\nZakres wartosci szczytowej: (40 – 5600) V/m\ndla wspolczynnika wypelnienia ti/Tp: < 0,005\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 9,2 GHz R.m.s. value range: Peak value range: for duty cycle ti/Tp: < 0,005 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 有效值范围： 峰值范围： Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）","parameters_zh":[{"name":"w zakresie częstotliwości od 9,2 GHz","range":"do 15,6 GHz"},{"name":"有效值范围：","range":"(2,8 – 400) V/m"},{"name":"峰值范围：","range":"(40 – 5600) V/m"},{"name":"dla współczynnika wypełnienia ti/Tp: < 0,005"}]},{"_id":"6a5dc9aef1c10c8ce825b08f","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 150 MHz","range":"do 60 GHz"},{"name":"Zakres wartości skutecznej:","range":"(0,7 – 1000) V/m"},{"name":"dla współczynnika wypełnienia ti/Tp = 1"}],"parameters_en":[{"name":"in the frequency range from 150 MHz","range":"do 60 GHz"},{"name":"R.m.s. value range:","range":"(0,7 – 1000) V/m"},{"name":"for duty cycle ti/Tp = 1"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 60 GHz\nZakres wartości skutecznej: (0,7 – 1000) V/m\ndla współczynnika wypełnienia ti/Tp = 1\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 60 GHz\nZakres wartości skutecznej: (0,7 – 1000) V/m\ndla współczynnika wypełnienia ti/Tp = 1\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 150 MHz do 60 GHz\nZakres wartosci skutecznej: (0,7 – 1000) V/m\ndla wspolczynnika wypelnienia ti/Tp = 1\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 150 MHz R.m.s. value range: for duty cycle ti/Tp = 1 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 150 MHz 起 有效值范围： Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）","parameters_zh":[{"name":"频率范围自 150 MHz 起","range":"do 60 GHz"},{"name":"有效值范围：","range":"(0,7 – 1000) V/m"},{"name":"dla współczynnika wypełnienia ti/Tp = 1"}]},{"_id":"6a5dc9aef1c10c8ce825b090","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10) A/m"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 10) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 10) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10) A/m"}],"search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b091","lab_id":"69ad52a3de79e566650fb1db","country":"PL","accr_number":"AB 366","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 150 MHz","range":"do 15,6 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 150 MHz","range":"do 15,6 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 15,6 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 150 MHz do 15,6 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 150 MHz do 15,6 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radar and radionavigation installations (broadband measurements) Magnetic field strength: in the frequency range from 150 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 150 MHz 起","range":"do 15,6 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 150 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 雷达与无线电导航设施周围的电磁场（宽带测量）"}],"has_pdf":true}