🇵🇱 ZARZĄD MORSKICH PORTÓW SZCZECIN I ŚWINOUJŚCIE PL
Water & wastewaterEnvironment
ZARZĄD MORSKICH PORTÓW SZCZECIN I ŚWINOUJŚCIE is a laboratory accredited by PCA under number AB 362 (Szczecin, Poland). Its accreditation scope covers 26 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, Workplace environment – hand-arm mechanical vibration, Workplace environment – noise. Most frequently used techniques: Direct measurement method, Optical method, Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 362
- Methods in scope: 26
- Types of test objects: 8
- Techniques used: 10
- City: Szczecin, Poland
- Accreditation number
- AB 362
- Accreditation body
- PCA
- Address
- SPÓŁKA AKCYJNA, LABORATORIUM BADAŃ ŚRODOWISKA I HIGIENY PRACY, ul. Bytomska 7, 70-603 Szczecin
- City
- Szczecin, Poland
What this laboratory tests (8)
- Water, wastewater — 13 methods
- Water — 4 methods
- Workplace environment – hand-arm mechanical vibration — 2 methods
- Workplace environment – noise — 2 methods
- Workplace environment – whole-body mechanical vibration — 2 methods
- Bottom sediments — 1 method
- Soil — 1 method
- Wastewater — 1 method
Analytical techniques used (10)
- Direct measurement method — 3 methods
- Optical method — 3 methods
- Spectrophotometric method — 3 methods
- Gravimetric method — 2 methods
- Titrimetric method — 2 methods
- Conductometric method — 1 method
- Manual method; Automatic method — 1 method
- Method using a transparency reference disc — 1 method
- Potentiometric method — 1 method
- Volumetric method — 1 method
Laboratory locations
- LABORATORIUM BADAŃ ŚRODOWISKA I HIGIENY PRACY — ul. Bytomska 7
Accreditation scope — test methods (26)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Environment and Occupational Hygiene Testing Laboratory | |||||
| 1 | Workplace environment – noise | A-weighted equivalent sound level A-weighted maximum sound level C-weighted equivalent sound level C-weighted peak sound level Range (44 – 136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | |
| 2 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the working week (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | ||
| 3 | Workplace environment – whole-body mechanical vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 – 7,7) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 4 | Workplace environment – whole-body mechanical vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 5 | Workplace environment – hand-arm mechanical vibration | Frequency-weighted r.m.s. vibration acceleration Range (1,0 – 20) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 6 | Workplace environment – hand-arm mechanical vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 7 | Water | Sampling for chemical and physical testing Temperature Range (0,0 – 50,0) °C |
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6 | PN-77/C-04584 | ||
| 8 | Water | Sampling for chemical and physical testing Temperature Range (0,0 – 50,0) °C |
PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15 | PN-77/C-04584 | ||
| 9 | Water | Sampling for chemical and physical testing Temperature Range (0,0 – 50,0) °C |
PN-ISO 5667-9:2005 | PN-77/C-04584 | ||
| 10 | Water | Transparency Range (0,5 – 10,0) m |
Method using a transparency reference disc | PN-EN ISO 7027-2:2019-04, pkt 5.2 | |
| 11 | Wastewater | Sampling for chemical and physical testing Temperature Range (0,0 – 50,0) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 12 | Soil | Sampling for chemical and physical testing | PN-ISO 10381-5:2009 | ||
| 13 | Bottom sediments | Sampling for chemical and physical testing | ISO 5667-12:2017 | PN-EN ISO 5667-19:2006 | ||
| 14 | Water, wastewater | Biochemical oxygen demand BOD5 Range (2 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 15 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,80 – 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r. | |
| 16 | Water, wastewater | Chemical oxygen demand CODCr Range (6,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 17 | Water, wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 18 | Water, wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 19 | Water, wastewater | Chloride concentration Range (5,0 – 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 20 | Water, wastewater | Sulfate concentration Range (10 – 700) mg/l |
Spectrophotometric method | ILB-07 wydanie 4 z dnia 16.10.2023 r. | na podstawie metody HACH 8051 | |
| 21 | Water, wastewater | Ammonium nitrogen concentration Range (1,0 – 500) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 22 | Water, wastewater | Nitrite nitrogen concentration Range (0,002 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 23 | Water, wastewater | Concentration of substances extractable with petroleum ether Range (3 – 1000) mg/l |
Gravimetric method | PN-86/C-04573/01 | |
| 24 | Water, wastewater | Dissolved oxygen concentration Range (0,5 – 12) mg/l O2 Percentage saturation Range (1 – 120) % |
Optical method | ISO 17289:2014 | |
| 25 | Water, wastewater | Settleable solids Range (0,50 – 200) ml/l |
Volumetric method | PN-72/C-04559/03 | |
| 26 | Water, wastewater | Electrical conductivity Range (500 – 12880) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
Reference standards (29)
ILB-07 wydanie 4 z dnia 16.10.2023 r.
ISO 17289:2014
ISO 5667-12:2017
PN-72/C-04559/03
PN-77/C-04584
PN-86/C-04573/01
PN-EN 14253+A1:2011
PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r.
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 5667-19:2006
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-2:2019-04, pkt 5.2
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
PN-ISO 10381-5:2009
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15
PN-ISO 5667-9:2005
PN-ISO 9297:1994
PN-N-01307:1994
na podstawie metody HACH 8051