{"lab":{"_id":"69ad52a3de79e566650fb1d7","accr_number":"AB 362","country":"PL","accr_body":"PCA","address":"SPÓŁKA AKCYJNA, LABORATORIUM BADAŃ ŚRODOWISKA I HIGIENY PRACY, ul. Bytomska 7, 70-603 Szczecin","categories":["water","environment"],"city":"Szczecin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":26,"name":"ZARZĄD MORSKICH PORTÓW SZCZECIN I ŚWINOUJŚCIE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_362.pdf"],"scope_summary":"","search_text":"zarząd morskich portów szczecin i świnoujście spółka akcyjna, laboratorium badań środowiska i higieny pracy, ul. bytomska 7, 70-603 szczecin environment other metrology water pharma electronics","status":"active","updated_at":"2026-03-08T14:51:11.756Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:05:46.971Z","location":{"type":"Point","coordinates":[14.5528,53.4285]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20362,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful factors – noise, vibration)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"P/31; P/32","pl":"Pobieranie próbek gleby, osadów","en":"Sampling of soil, sediments"}],"issue":{"no":"28","date":"16.07.2026"},"parse_date":"2026-08-13T08:05:46.971Z","parse_source":"agent-claude-code","map_coord":[53.417801,14.571083],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAŃ ŚRODOWISKA I HIGIENY PRACY","address":"ul. Bytomska 7","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/8277f67b2efb28352215aacd0e79b030/AB%20362.pdf","has_en":true,"category_counts":{"water":19,"environment":7,"metrology":1},"category_scores":{"water":13.37,"environment":1.81,"metrology":0.04},"has_zh":true},"methods":[{"_id":"6a7d7ada0636ba417e41ba21","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Równoważny poziom dźwięku C Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(44 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Równoważny poziom dźwięku C Szczytowy poziom dźwięku C\nZakres (44 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Równoważny poziom dźwięku C Szczytowy poziom dźwięku C\nZakres (44 – 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Rownowazny poziom dzwieku C Szczytowy poziom dzwieku C\nZakres (44 – 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level C-weighted equivalent sound level C-weighted peak sound level","parameters_en":[{"name":"Range","range":"(44 – 136) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level A-weighted maximum sound level C-weighted equivalent sound level C-weighted peak sound level Direct measurement method Environment and Occupational Hygiene Testing Laboratory Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","parameters_zh":[{"name":"范围","range":"(44 – 136) dB"}],"search_zh":"工作场所环境 — 噪声 直接测量法 环境与职业卫生检测实验室 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba22","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"tygodnia pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the working week (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: Environment and Occupational Hygiene Testing Laboratory an 8-hour daily working time the working week (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 环境与职业卫生检测实验室 8 小时日工作时间 工作周（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"工作周（由计算得出）"}],"lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba23","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,02 – 7,7) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 – 7,7) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 – 7,7) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania mechaniczne o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,02 – 7,7) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,02 – 7,7) m/s2"}],"search_en":"Workplace environment – whole-body mechanical vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Environment and Occupational Hygiene Testing Laboratory Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body mechanical vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,02 – 7,7) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的机械振动 频率计权振动加速度有效值 直接测量法 环境与职业卫生检测实验室 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","lab_section_zh":"环境与职业卫生检测实验室","test_object_zh":"工作环境 － 对人体产生全身作用的机械振动"},{"_id":"6a7d7ada0636ba417e41ba24","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania mechaniczne o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated)","search_en":"Workplace environment – whole-body mechanical vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) Environment and Occupational Hygiene Testing Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body mechanical vibration","lab_section_zh":"环境与职业卫生检测实验室","search_zh":"工作环境 － 对人体产生全身作用的机械振动 日暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出） 环境与职业卫生检测实验室 PN-EN 14253+A1:2011","test_object_zh":"工作环境 － 对人体产生全身作用的机械振动","methodology_zh":"日暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）"},{"_id":"6a7d7ada0636ba417e41ba25","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(1,0 – 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (1,0 – 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (1,0 – 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania mechaniczne dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (1,0 – 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(1,0 – 20) m/s2"}],"search_en":"Workplace environment – hand-arm mechanical vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Environment and Occupational Hygiene Testing Laboratory Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm mechanical vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(1,0 – 20) m/s2"}],"search_zh":"工作环境 － 经上肢作用于人体的机械振动 频率计权振动加速度有效值 直接测量法 环境与职业卫生检测实验室 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","lab_section_zh":"环境与职业卫生检测实验室","test_object_zh":"工作环境 － 经上肢作用于人体的机械振动"},{"_id":"6a7d7ada0636ba417e41ba26","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania mechaniczne działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania mechaniczne dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm mechanical vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) Environment and Occupational Hygiene Testing Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm mechanical vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作环境 － 经上肢作用于人体的机械振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） 环境与职业卫生检测实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","lab_section_zh":"环境与职业卫生检测实验室","test_object_zh":"工作环境 － 经上肢作用于人体的机械振动"},{"_id":"6a7d7ada0636ba417e41ba27","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6","PN-77/C-04584"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.6 | PN-77/C-04584","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Environment and Occupational Hygiene Testing Laboratory Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 化学和物理检测采样 温度 环境与职业卫生检测实验室 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.6 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"环境与职业卫生检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d7ada0636ba417e41ba28","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C","reference":"PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15 | PN-77/C-04584","norm_bases":["PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15","PN-77/C-04584"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C PN-ISO 5667-4:2017-10 z wylaczeniem pkt 15 | PN-77/C-04584","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Environment and Occupational Hygiene Testing Laboratory Range PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 化学和物理检测采样 温度 环境与职业卫生检测实验室 范围 PN-ISO 5667-4:2017-10 z wyłączeniem pkt 15 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"环境与职业卫生检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d7ada0636ba417e41ba29","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C","reference":"PN-ISO 5667-9:2005 | PN-77/C-04584","norm_bases":["PN-ISO 5667-9:2005","PN-77/C-04584"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C PN-ISO 5667-9:2005 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 – 50,0) °C PN-ISO 5667-9:2005 | PN-77/C-04584","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Environment and Occupational Hygiene Testing Laboratory Range PN-ISO 5667-9:2005 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 化学和物理检测采样 温度 环境与职业卫生检测实验室 范围 PN-ISO 5667-9:2005 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"环境与职业卫生检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d7ada0636ba417e41ba2a","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda","methodology":"Przezroczystość","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) m"}],"technique":"Metoda z zastosowaniem krążka wzorcowego przezroczystości","techniques":["Metoda z zastosowaniem krążka wzorcowego przezroczystości"],"computed":[],"activity":"Przezroczystość\nZakres (0,5 – 10,0) m\nMetoda z zastosowaniem krążka wzorcowego przezroczystości","reference":"PN-EN ISO 7027-2:2019-04, pkt 5.2","norm_bases":["PN-EN ISO 7027-2:2019-04, pkt 5.2"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przezroczystość\nZakres (0,5 – 10,0) m\nMetoda z zastosowaniem krążka wzorcowego przezroczystości PN-EN ISO 7027-2:2019-04, pkt 5.2 Woda Przezroczystosc\nZakres (0,5 – 10,0) m\nMetoda z zastosowaniem krazka wzorcowego przezroczystosci PN-EN ISO 7027-2:2019-04, pkt 5.2","categories":["water","metrology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Transparency","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) m"}],"search_en":"Water Transparency Method using a transparency reference disc Environment and Occupational Hygiene Testing Laboratory Range PN-EN ISO 7027-2:2019-04, pkt 5.2","technique_en":"Method using a transparency reference disc","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) m"}],"search_zh":"水 环境与职业卫生检测实验室 范围 PN-EN ISO 7027-2:2019-04, pkt 5.2","test_object_zh":"水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba2b","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Environment and Occupational Hygiene Testing Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 环境与职业卫生检测实验室 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba2c","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-5:2009","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing Environment and Occupational Hygiene Testing Laboratory PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 环境与职业卫生检测实验室 PN-ISO 10381-5:2009","test_object_zh":"土壤","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba2d","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Osady denne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ISO 5667-12:2017 | PN-EN ISO 5667-19:2006","norm_bases":["ISO 5667-12:2017","PN-EN ISO 5667-19:2006"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Pobieranie próbek do badań chemicznych i fizycznych ISO 5667-12:2017 | PN-EN ISO 5667-19:2006 Osady denne Pobieranie probek do badan chemicznych i fizycznych ISO 5667-12:2017 | PN-EN ISO 5667-19:2006","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Bottom sediments Sampling for chemical and physical testing Environment and Occupational Hygiene Testing Laboratory ISO 5667-12:2017 | PN-EN ISO 5667-19:2006","test_object_en":"Bottom sediments","methodology_zh":"化学与物理检测用样品采集","search_zh":"底泥 化学与物理检测用样品采集 环境与职业卫生检测实验室 ISO 5667-12:2017 | PN-EN ISO 5667-19:2006","lab_section_zh":"环境与职业卫生检测实验室","test_object_zh":"底泥"},{"_id":"6a7d7ada0636ba417e41ba2e","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(2 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(2 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Optical method Environment and Occupational Hygiene Testing Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(2 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 光学法 环境与职业卫生检测实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba2f","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,80 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,80 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r.","norm_bases":["PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r."],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,80 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r. Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,80 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r.","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,80 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Optical method Environment and Occupational Hygiene Testing Laboratory BOD5 Range PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r.","technique_en":"Optical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,80 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 光学法 环境与职业卫生检测实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002 ILB-26 wydanie 01 z dnia 1.10.2020 r.","technique_zh":"光学法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba30","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZTCr"},{"name":"Zakres","range":"(6,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZTCr\nZakres (6,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZTCr\nZakres (6,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZTCr\nZakres (6,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"CODCr"},{"name":"Range","range":"(6,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand Spectrophotometric method Environment and Occupational Hygiene Testing Laboratory CODCr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"COD-Cr"},{"name":"范围","range":"(6,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD） 分光光度法 环境与职业卫生检测实验室 COD-Cr 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD）","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba31","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Environment and Occupational Hygiene Testing Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 环境与职业卫生检测实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba32","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, wastewater pH Potentiometric method Environment and Occupational Hygiene Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 环境与职业卫生检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba33","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Environment and Occupational Hygiene Testing Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 环境与职业卫生检测实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba34","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 700) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 700) mg/l\nMetoda spektrofotometryczna","reference":"ILB-07 wydanie 4 z dnia 16.10.2023 r. | na podstawie metody HACH 8051","norm_bases":["ILB-07 wydanie 4 z dnia 16.10.2023 r.","na podstawie metody HACH 8051"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 700) mg/l\nMetoda spektrofotometryczna ILB-07 wydanie 4 z dnia 16.10.2023 r. | na podstawie metody HACH 8051 Woda, scieki Stezenie siarczanow\nZakres (10 – 700) mg/l\nMetoda spektrofotometryczna ILB-07 wydanie 4 z dnia 16.10.2023 r. | na podstawie metody HACH 8051","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 700) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Environment and Occupational Hygiene Testing Laboratory Range ILB-07 wydanie 4 z dnia 16.10.2023 r. | na podstawie metody HACH 8051","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 700) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 环境与职业卫生检测实验室 范围 ILB-07 wydanie 4 z dnia 16.10.2023 r. | na podstawie metody HACH 8051","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba35","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Environment and Occupational Hygiene Testing Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 环境与职业卫生检测实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba36","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,002 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,002 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 10) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Environment and Occupational Hygiene Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 10) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 环境与职业卫生检测实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba37","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(3 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (3 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (3 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (3 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(3 – 1000) mg/l"}],"search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Environment and Occupational Hygiene Testing Laboratory Range PN-86/C-04573/01","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 1000) mg/l"}],"search_zh":"水、废水 石油醚可萃取物浓度 重量法 环境与职业卫生检测实验室 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物浓度","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba38","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 12) mg/l O2"},{"name":"Procent nasycenia"},{"name":"Zakres","range":"(1 – 120) %"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 12) mg/l O2\nProcent nasycenia\nZakres (1 – 120) %\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 12) mg/l O2\nProcent nasycenia\nZakres (1 – 120) %\nMetoda optyczna ISO 17289:2014 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 12) mg/l O2\nProcent nasycenia\nZakres (1 – 120) %\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 12) mg/l O2"},{"name":"Percentage saturation"},{"name":"Range","range":"(1 – 120) %"}],"search_en":"Water, wastewater Dissolved oxygen concentration Optical method Environment and Occupational Hygiene Testing Laboratory Range Percentage saturation Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 12) mg/l O2"},{"name":"Procent nasycenia"},{"name":"范围","range":"(1 – 120) %"}],"search_zh":"水、废水 溶解氧浓度 光学法 环境与职业卫生检测实验室 范围 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度","lab_section_zh":"环境与职业卫生检测实验室"},{"_id":"6a7d7ada0636ba417e41ba39","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zakres","range":"(0,50 – 200) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres (0,50 – 200) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny łatwoopadające\nZakres (0,50 – 200) ml/l\nMetoda objętościowa PN-72/C-04559/03 Woda, scieki Zawiesiny latwoopadajace\nZakres (0,50 – 200) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,50 – 200) ml/l"}],"search_en":"Water, wastewater Settleable solids Volumetric method Environment and Occupational Hygiene Testing Laboratory Range PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 200) ml/l"}],"search_zh":"水、废水 易沉降悬浮物 容量法 环境与职业卫生检测实验室 范围 PN-72/C-04559/03","test_object_zh":"水、废水","technique_zh":"容量法","lab_section_zh":"环境与职业卫生检测实验室","methodology_zh":"易沉降悬浮物"},{"_id":"6a7d7ada0636ba417e41ba3a","lab_id":"69ad52a3de79e566650fb1d7","country":"PL","accr_number":"AB 362","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(500 – 12880) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (500 – 12880) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badań Środowiska i Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (500 – 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (500 – 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environment and Occupational Hygiene Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(500 – 12880) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Environment and Occupational Hygiene Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(500 – 12880) μS/cm"}],"search_zh":"水、废水 电导率 电导法 环境与职业卫生检测实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水","lab_section_zh":"环境与职业卫生检测实验室"}],"has_pdf":true}