🇵🇱 POLITECHNIKA WROCŁAWSKA PL
Electronics & EMCEnvironmentAutomotive
POLITECHNIKA WROCŁAWSKA is a laboratory accredited by PCA under number AB 361 (Wrocław, Poland). Its accreditation scope covers 28 test methods in the following areas: Electronics & EMC, Environment, Automotive. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment – electromagnetic field in the workspace duri…, Workplace environment – electromagnetic field in the workspace duri…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).
At a glance
- Accreditation number: PCA AB 361
- Methods in scope: 28
- Types of test objects: 11
- Techniques used: 2
- City: Wrocław, Poland
- Accreditation number
- AB 361
- Accreditation body
- PCA
- Address
- Wybrzeże Stanisława Wyspiańskiego 27, 50-370 Wrocław, KATEDRA TELEKOMUNIKACJI I TELEINFORMATYKI, LABORATORIUM WZORCÓW i METROLOGII POLA ELEKTROMAGNETYCZNEGO
- City
- Wrocław, Poland
What this laboratory tests (11)
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) — 3 methods
- Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) — 3 methods
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners — 3 methods
- Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters — 3 methods
- Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems — 3 methods
- Environment - electromagnetic fields — 2 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 2 methods
- Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry — 2 methods
- Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices — 1 method
Analytical techniques used (2)
- Direct measurement method — 20 methods
- Direct measurement method (simplified) — 1 method
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Electric field strength: in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 30 kV/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1. | |
| 2 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Magnetic field strength: in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1. | |
| 3 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Magnetic field strength: in the frequency range from 1 do 3 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1. | ||
| 4 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems | Electric field strength: in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 30 kV/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2. | |
| 5 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2. | |
| 6 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 1 do 3 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2. | ||
| 7 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners | Electric field strength: in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 30 kV/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3. | |
| 8 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners | Magnetic field strength: in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3. | |
| 9 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners | Magnetic field strength: in the frequency range from 1 do 3 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3. | ||
| 10 | Environment - electromagnetic fields | Electric field strength: in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 50 kV/m |
Direct measurement method | PN-EN 62233:2008 | PN-EN 62311:2020 | |
| 11 | Environment - electromagnetic fields | Magnetic field strength: in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m |
Direct measurement method | PN-EN 62233:2008 | PN-EN 62311:2020 | |
| 12 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range from 10 Hz do 400 kHz Range (1 – 50000) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | |
| 13 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Magnetic field strength: in the frequency range from 10 Hz do 400 kHz Range (0,1 – 16 000) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | |
| 14 | Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices | Magnetic field strength: in the frequency range from 10 Hz do 400 kHz Range (0,005 - 16 000) A/m |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 | |
| 15 | Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) | Electric field strength: in the frequency range from 100 kHz do 90 GHz Range (0,01 – 1200) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 16 | Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) | Magnetic field strength: in the frequency range from 100 kHz do 1 GHz Range (0,01 – 16) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 17 | Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) | Magnetic field strength: in the frequency range from 0,8 GHz do 90 GHz (calculated) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 18 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) | Electric field strength: in the frequency range from 100 kHz do 90 GHz Range (0,01 – 1200) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | |
| 19 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) | Magnetic field strength: in the frequency range from 100 kHz do 1 GHz Range (0,01 – 16) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | |
| 20 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) | Magnetic field strength: in the frequency range from 0,8 GHz do 90 GHz (calculated) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | ||
| 21 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (1 – 50000) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | |
| 22 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range from 0 Hz do 0,5 Hz Range (0,1 – 1000) kA/m in the frequency range 50 Hz Range (0,1 – 16000) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | |
| 23 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 3 kHz do 500 kHz Range (1 – 50000) V/m in the frequency range from 100 kHz do 18 GHz Range (0,1 – 1200) V/m in the frequency range from 80 MHz do 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | |
| 24 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 3 kHz do 500 kHz Range (0,1 – 16000) A/m in the frequency range from 100 kHz do 1 GHz Range (0,01 – 16) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | |
| 25 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz do 90 GHz (calculated) |
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | ||
| 26 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) | Electric field strength: in the frequency range from 3 kHz do 500 kHz Range (1 – 50000) V/m in the frequency range from 27 MHz do 6 GHz Range (0,001 – 200) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | |
| 27 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) | Magnetic field strength: in the frequency range from 3 kHz do 500 kHz Range (0,1 – 16000) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | |
| 28 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) | Magnetic field strength: in the frequency range from 27 MHz do 6 GHz (calculated) |
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) | ||
Reference standards (11)
PN-EN 62233:2008
PN-EN 62311:2020
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)