🇵🇱 POLITECHNIKA WROCŁAWSKA PL

PCA AB 361 • Wrocław, Poland • 28 methods

Electronics & EMCEnvironmentAutomotive

POLITECHNIKA WROCŁAWSKA is a laboratory accredited by PCA under number AB 361 (Wrocław, Poland). Its accreditation scope covers 28 test methods in the following areas: Electronics & EMC, Environment, Automotive. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment – electromagnetic field in the workspace duri…, Workplace environment – electromagnetic field in the workspace duri…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 361
  • Methods in scope: 28
  • Types of test objects: 11
  • Techniques used: 2
  • City: Wrocław, Poland
Accreditation number
AB 361
Accreditation body
PCA
Address
Wybrzeże Stanisława Wyspiańskiego 27, 50-370 Wrocław, KATEDRA TELEKOMUNIKACJI I TELEINFORMATYKI, LABORATORIUM WZORCÓW i METROLOGII POLA ELEKTROMAGNETYCZNEGO
City
Wrocław, Poland

What this laboratory tests (11)

Analytical techniques used (2)

Accreditation scope — test methods (28)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Electric field strength:
in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 30 kV/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.
2 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength:
in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.
3 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength:
in the frequency range from 1 do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.
4 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 30 kV/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.
5 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.
6 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 1 do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.
7 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 30 kV/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.
8 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners Magnetic field strength:
in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.
9 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners Magnetic field strength:
in the frequency range from 1 do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.
10 Environment - electromagnetic fields Electric field strength:
in the frequency range from 10 Hz do 90 GHz Range 10 mV/m – 50 kV/m
Direct measurement method PN-EN 62233:2008 | PN-EN 62311:2020
11 Environment - electromagnetic fields Magnetic field strength:
in the frequency range from 0 Hz do 1 GHz Range 5 mA/m – 1600 kA/m
Direct measurement method PN-EN 62233:2008 | PN-EN 62311:2020
12 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 10 Hz do 400 kHz Range (1 – 50000) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
13 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength:
in the frequency range from 10 Hz do 400 kHz Range (0,1 – 16 000) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
14 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic field strength:
in the frequency range from 10 Hz do 400 kHz Range (0,005 - 16 000) A/m
Direct measurement method (simplified) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
15 Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) Electric field strength:
in the frequency range from 100 kHz do 90 GHz Range (0,01 – 1200) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
16 Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) Magnetic field strength:
in the frequency range from 100 kHz do 1 GHz Range (0,01 – 16) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
17 Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) Magnetic field strength:
in the frequency range from 0,8 GHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
18 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) Electric field strength:
in the frequency range from 100 kHz do 90 GHz Range (0,01 – 1200) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
19 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) Magnetic field strength:
in the frequency range from 100 kHz do 1 GHz Range (0,01 – 16) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
20 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) Magnetic field strength:
in the frequency range from 0,8 GHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
21 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1 – 50000) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
22 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range from 0 Hz do 0,5 Hz Range (0,1 – 1000) kA/m in the frequency range 50 Hz Range (0,1 – 16000) A/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
23 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Electric field strength:
in the frequency range from 3 kHz do 500 kHz Range (1 – 50000) V/m in the frequency range from 100 kHz do 18 GHz Range (0,1 – 1200) V/m in the frequency range from 80 MHz do 90 GHz Range (0,5 – 300) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
24 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 3 kHz do 500 kHz Range (0,1 – 16000) A/m in the frequency range from 100 kHz do 1 GHz Range (0,01 – 16) A/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
25 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz do 90 GHz (calculated)
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
26 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) Electric field strength:
in the frequency range from 3 kHz do 500 kHz Range (1 – 50000) V/m in the frequency range from 27 MHz do 6 GHz Range (0,001 – 200) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
27 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) Magnetic field strength:
in the frequency range from 3 kHz do 500 kHz Range (0,1 – 16000) A/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
28 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) Magnetic field strength:
in the frequency range from 27 MHz do 6 GHz (calculated)
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)

Reference standards (11)

PN-EN 62233:2008
PN-EN 62311:2020
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)