{"lab":{"_id":"69ad52a3de79e566650fb1d5","accr_number":"AB 361","country":"PL","accr_body":"PCA","address":"Wybrzeże Stanisława Wyspiańskiego 27, 50-370 Wrocław, KATEDRA TELEKOMUNIKACJI I TELEINFORMATYKI, LABORATORIUM WZORCÓW i METROLOGII POLA ELEKTROMAGNETYCZNEGO","categories":["environment","automotive","electronics"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"POLITECHNIKA WROCŁAWSKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_361.pdf"],"scope_summary":"","search_text":"politechnika wrocławska wybrzeże stanisława wyspiańskiego 27, 50-370 wrocław, katedra telekomunikacji i teleinformatyki, laboratorium wzorców i metrologii pola elektromagnetycznego environment pharma electronics metrology other materials automotive","status":"active","updated_at":"2026-03-08T14:51:11.702Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:11.702Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20361,podmiot.html","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne),","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"19","date":"17.09.2025"},"parse_date":"2026-07-20T07:09:34.906Z","parse_source":"script-pdfplumber","map_coord":[51.108978,17.032669],"map_geo":"nominatim-city","has_en":true,"category_counts":{"environment":28,"automotive":3,"electronics":3},"category_scores":{"environment":23.06,"automotive":0.26,"electronics":0.26},"has_zh":true},"methods":[{"_id":"6a5dc9aef1c10c8ce825b020","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 90 GHz"},{"name":"Zakres","range":"10 mV/m – 30 kV/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 90 GHz"},{"name":"Range","range":"10 mV/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznik 1.","categories":["environment","automotive"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Electric field strength: Direct measurement method in the frequency range from 10 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 90 GHz"},{"name":"范围","range":"10 mV/m – 30 kV/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b021","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0 Hz","range":"do 1 GHz"},{"name":"Zakres","range":"5 mA/m – 1600 kA/m"}],"parameters_en":[{"name":"in the frequency range from 0 Hz","range":"do 1 GHz"},{"name":"Range","range":"5 mA/m – 1600 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznik 1.","categories":["environment","automotive"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength: Direct measurement method in the frequency range from 0 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0 Hz 起","range":"do 1 GHz"},{"name":"范围","range":"5 mA/m – 1600 kA/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 0 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b022","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 1","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 1","range":"do 3 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1 do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznik 1.","categories":["environment","automotive"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength: in the frequency range from 1 (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 1 起","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 1 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 1."},{"_id":"6a5dc9aef1c10c8ce825b023","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","test_object_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 90 GHz"},{"name":"Zakres","range":"10 mV/m – 30 kV/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 90 GHz"},{"name":"Range","range":"10 mV/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznik 2.","categories":["environment","electronics"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems Electric field strength: Direct measurement method in the frequency range from 10 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 90 GHz"},{"name":"范围","range":"10 mV/m – 30 kV/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b024","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","test_object_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0 Hz","range":"do 1 GHz"},{"name":"Zakres","range":"5 mA/m – 1600 kA/m"}],"parameters_en":[{"name":"in the frequency range from 0 Hz","range":"do 1 GHz"},{"name":"Range","range":"5 mA/m – 1600 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznik 2.","categories":["environment","electronics"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength: Direct measurement method in the frequency range from 0 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0 Hz 起","range":"do 1 GHz"},{"name":"范围","range":"5 mA/m – 1600 kA/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 0 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b025","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","test_object_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 1","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 1","range":"do 3 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego i niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1 do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznik 2.","categories":["environment","electronics"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary and non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength: in the frequency range from 1 (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 1 起","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 1 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznik 2."},{"_id":"6a5dc9aef1c10c8ce825b026","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 90 GHz"},{"name":"Zakres","range":"10 mV/m – 30 kV/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 90 GHz"},{"name":"Range","range":"10 mV/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 90 GHz\nZakres 10 mV/m – 30 kV/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznikl 3.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners Electric field strength: Direct measurement method in the frequency range from 10 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 90 GHz"},{"name":"范围","range":"10 mV/m – 30 kV/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b027","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0 Hz","range":"do 1 GHz"},{"name":"Zakres","range":"5 mA/m – 1600 kA/m"}],"parameters_en":[{"name":"in the frequency range from 0 Hz","range":"do 1 GHz"},{"name":"Range","range":"5 mA/m – 1600 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznikl 3.","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners Magnetic field strength: Direct measurement method in the frequency range from 0 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0 Hz 起","range":"do 1 GHz"},{"name":"范围","range":"5 mA/m – 1600 kA/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 0 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b028","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 1","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 1","range":"do 3 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1 do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Zalacznikl 3.","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy - physiotherapy diathermy magnetic resonance scanners Magnetic field strength: in the frequency range from 1 (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3.","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 1 起","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 1 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Procedura PrB-1, wyd. 4 z 25.07.24, Załącznikl 3."},{"_id":"6a5dc9aef1c10c8ce825b029","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko - pola elektromagnetyczne","test_object_en":"Environment - electromagnetic fields","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 90 GHz"},{"name":"Zakres","range":"10 mV/m – 50 kV/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 90 GHz"},{"name":"Range","range":"10 mV/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 62233:2008 | PN-EN 62311:2020","norm_bases":["PN-EN 62233:2008","PN-EN 62311:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pola elektromagnetyczne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 90 GHz\nZakres 10 mV/m – 50 kV/m\nMetoda pomiarowa bezpośrednia PN-EN 62233:2008 | PN-EN 62311:2020 Srodowisko - pola elektromagnetyczne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 90 GHz\nZakres 10 mV/m – 50 kV/m\nMetoda pomiarowa bezposrednia PN-EN 62233:2008 | PN-EN 62311:2020","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic fields Electric field strength: Direct measurement method in the frequency range from 10 Hz Range PN-EN 62233:2008 | PN-EN 62311:2020","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 90 GHz"},{"name":"范围","range":"10 mV/m – 50 kV/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 10 Hz 起 范围 PN-EN 62233:2008 | PN-EN 62311:2020","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b02a","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko - pola elektromagnetyczne","test_object_en":"Environment - electromagnetic fields","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0 Hz","range":"do 1 GHz"},{"name":"Zakres","range":"5 mA/m – 1600 kA/m"}],"parameters_en":[{"name":"in the frequency range from 0 Hz","range":"do 1 GHz"},{"name":"Range","range":"5 mA/m – 1600 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 62233:2008 | PN-EN 62311:2020","norm_bases":["PN-EN 62233:2008","PN-EN 62311:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pola elektromagnetyczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezpośrednia PN-EN 62233:2008 | PN-EN 62311:2020 Srodowisko - pola elektromagnetyczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0 Hz do 1 GHz\nZakres 5 mA/m – 1600 kA/m\nMetoda pomiarowa bezposrednia PN-EN 62233:2008 | PN-EN 62311:2020","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment - electromagnetic fields Magnetic field strength: Direct measurement method in the frequency range from 0 Hz Range PN-EN 62233:2008 | PN-EN 62311:2020","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0 Hz 起","range":"do 1 GHz"},{"name":"范围","range":"5 mA/m – 1600 kA/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 0 Hz 起 范围 PN-EN 62233:2008 | PN-EN 62311:2020","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b02b","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b02c","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,1 – 16 000) A/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(0,1 – 16 000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 16 000) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 16 000) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (0,1 – 16 000) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength: Direct measurement method in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,1 – 16 000) A/m"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 磁场强度： 直接测量法 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b02d","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,005 - 16 000) A/m"}],"parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(0,005 - 16 000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"technique_en":"Direct measurement method (simplified)","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,005 - 16 000) A/m\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,005 - 16 000) A/m\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (0,005 - 16 000) A/m\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic field strength: Direct measurement method (simplified) in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,005 - 16 000) A/m"}],"search_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场 磁场强度： 直接测量法（简化） 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_zh":"直接测量法（简化）","test_object_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b02e","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej)","test_object_en":"Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 90 GHz"},{"name":"Zakres","range":"(0,01 – 1200) V/m"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 90 GHz"},{"name":"Range","range":"(0,01 – 1200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 90 GHz\nZakres (0,01 – 1200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 90 GHz\nZakres (0,01 – 1200) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 90 GHz\nZakres (0,01 – 1200) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) Electric field strength: Direct measurement method in the frequency range from 100 kHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 90 GHz"},{"name":"范围","range":"(0,01 – 1200) V/m"}],"search_zh":"工作环境 – 使用无线电通信系统发射设备（移动电话基站）时工作空间内的电磁场 电场强度： 直接测量法 频率范围自 100 kHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 – 使用无线电通信系统发射设备（移动电话基站）时工作空间内的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b02f","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej)","test_object_en":"Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 16) A/m"}],"search_zh":"工作环境 – 使用无线电通信系统发射设备（移动电话基站）时工作空间内的电磁场 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 – 使用无线电通信系统发射设备（移动电话基站）时工作空间内的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b030","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej)","test_object_en":"Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 90 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 90 GHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace during operation of radiocommunication transmitting equipment (mobile telephony base stations) Magnetic field strength: in the frequency range from 0,8 GHz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 – 使用无线电通信系统发射设备（移动电话基站）时工作空间内的电磁场 磁场强度： 频率范围自 0,8 GHz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","test_object_zh":"工作环境 – 使用无线电通信系统发射设备（移动电话基站）时工作空间内的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b031","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.)","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 90 GHz"},{"name":"Zakres","range":"(0,01 – 1200) V/m"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 90 GHz"},{"name":"Range","range":"(0,01 – 1200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 90 GHz\nZakres (0,01 – 1200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 90 GHz\nZakres (0,01 – 1200) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 90 GHz\nZakres (0,01 – 1200) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 – 131","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) Electric field strength: Direct measurement method in the frequency range from 100 kHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 90 GHz"},{"name":"范围","range":"(0,01 – 1200) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 100 kHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b032","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.)","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"}],"parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 – 131","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 16) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b033","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.)","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 90 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (nadawcze systemy tele- i radiokomunikacyjne – radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 90 GHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 – 131","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems – radio, television, etc.) Magnetic field strength: in the frequency range from 0,8 GHz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 0,8 GHz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"},{"_id":"6a5dc9aef1c10c8ce825b034","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b035","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 0 Hz","range":"do 0,5 Hz"},{"name":"Zakres","range":"(0,1 – 1000) kA/m"},{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(0,1 – 16000) A/m"}],"parameters_en":[{"name":"in the frequency range from 0 Hz","range":"do 0,5 Hz"},{"name":"Range","range":"(0,1 – 1000) kA/m"},{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(0,1 – 16000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 0,5 Hz\nZakres (0,1 – 1000) kA/m\nw zakresie częstotliwości 50 Hz\nZakres (0,1 – 16000) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0 Hz do 0,5 Hz\nZakres (0,1 – 1000) kA/m\nw zakresie częstotliwości 50 Hz\nZakres (0,1 – 16000) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0 Hz do 0,5 Hz\nZakres (0,1 – 1000) kA/m\nw zakresie czestotliwosci 50 Hz\nZakres (0,1 – 16000) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: Direct measurement method in the frequency range from 0 Hz Range in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0 Hz 起","range":"do 0,5 Hz"},{"name":"范围","range":"(0,1 – 1000) kA/m"},{"name":"频率范围 50 Hz"},{"name":"范围","range":"(0,1 – 16000) A/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度： 直接测量法 频率范围自 0 Hz 起 范围 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5dc9aef1c10c8ce825b036","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 3 kHz","range":"do 500 kHz"},{"name":"Zakres","range":"(1 – 50000) V/m"},{"name":"w zakresie częstotliwości od 100 kHz","range":"do 18 GHz"},{"name":"Zakres","range":"(0,1 – 1200) V/m"},{"name":"w zakresie częstotliwości od 80 MHz","range":"do 90 GHz"},{"name":"Zakres","range":"(0,5 – 300) V/m"}],"parameters_en":[{"name":"in the frequency range from 3 kHz","range":"do 500 kHz"},{"name":"Range","range":"(1 – 50000) V/m"},{"name":"in the frequency range from 100 kHz","range":"do 18 GHz"},{"name":"Range","range":"(0,1 – 1200) V/m"},{"name":"in the frequency range from 80 MHz","range":"do 90 GHz"},{"name":"Range","range":"(0,5 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (1 – 50000) V/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,1 – 1200) V/m\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (1 – 50000) V/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,1 – 1200) V/m\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 3 kHz do 500 kHz\nZakres (1 – 50000) V/m\nw zakresie czestotliwosci od 100 kHz do 18 GHz\nZakres (0,1 – 1200) V/m\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 3 kHz Range in the frequency range from 100 kHz Range in the frequency range from 80 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 3 kHz 起","range":"do 500 kHz"},{"name":"范围","range":"(1 – 50000) V/m"},{"name":"频率范围自 100 kHz 起","range":"do 18 GHz"},{"name":"范围","range":"(0,1 – 1200) V/m"},{"name":"频率范围自 80 MHz 起","range":"do 90 GHz"},{"name":"范围","range":"(0,5 – 300) V/m"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 3 kHz 起 范围 频率范围自 100 kHz 起 范围 频率范围自 80 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b037","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 3 kHz","range":"do 500 kHz"},{"name":"Zakres","range":"(0,1 – 16000) A/m"},{"name":"w zakresie częstotliwości od 100 kHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"}],"parameters_en":[{"name":"in the frequency range from 3 kHz","range":"do 500 kHz"},{"name":"Range","range":"(0,1 – 16000) A/m"},{"name":"in the frequency range from 100 kHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (0,1 – 16000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (0,1 – 16000) A/m\nw zakresie częstotliwości od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 3 kHz do 500 kHz\nZakres (0,1 – 16000) A/m\nw zakresie czestotliwosci od 100 kHz do 1 GHz\nZakres (0,01 – 16) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength: Direct measurement method in the frequency range from 3 kHz Range in the frequency range from 100 kHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 3 kHz 起","range":"do 500 kHz"},{"name":"范围","range":"(0,1 – 16000) A/m"},{"name":"频率范围自 100 kHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 16) A/m"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 频率范围自 3 kHz 起 范围 频率范围自 100 kHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b038","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 10 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń) Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 90 GHz\n(z obliczen) Punkt. 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength: in the frequency range from 10 MHz (calculated) Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 MHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 10 MHz 起 （计算得出） Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9aef1c10c8ce825b039","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości od 3 kHz","range":"do 500 kHz"},{"name":"Zakres","range":"(1 – 50000) V/m"},{"name":"w zakresie częstotliwości od 27 MHz","range":"do 6 GHz"},{"name":"Zakres","range":"(0,001 – 200) V/m"}],"parameters_en":[{"name":"in the frequency range from 3 kHz","range":"do 500 kHz"},{"name":"Range","range":"(1 – 50000) V/m"},{"name":"in the frequency range from 27 MHz","range":"do 6 GHz"},{"name":"Range","range":"(0,001 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (1 – 50000) V/m\nw zakresie częstotliwości od 27 MHz do 6 GHz\nZakres (0,001 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (1 – 50000) V/m\nw zakresie częstotliwości od 27 MHz do 6 GHz\nZakres (0,001 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 3 kHz do 500 kHz\nZakres (1 – 50000) V/m\nw zakresie czestotliwosci od 27 MHz do 6 GHz\nZakres (0,001 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) Electric field strength: Direct measurement method in the frequency range from 3 kHz Range in the frequency range from 27 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 3 kHz 起","range":"do 500 kHz"},{"name":"范围","range":"(1 – 50000) V/m"},{"name":"频率范围自 27 MHz 起","range":"do 6 GHz"},{"name":"范围","range":"(0,001 – 200) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 3 kHz 起 范围 频率范围自 27 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b03a","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 3 kHz","range":"do 500 kHz"},{"name":"Zakres","range":"(0,1 – 16000) A/m"}],"parameters_en":[{"name":"in the frequency range from 3 kHz","range":"do 500 kHz"},{"name":"Range","range":"(0,1 – 16000) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (0,1 – 16000) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 3 kHz do 500 kHz\nZakres (0,1 – 16000) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 3 kHz do 500 kHz\nZakres (0,1 – 16000) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) Magnetic field strength: Direct measurement method in the frequency range from 3 kHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 3 kHz 起","range":"do 500 kHz"},{"name":"范围","range":"(0,1 – 16000) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 3 kHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","technique_zh":"直接测量法"},{"_id":"6a5dc9aef1c10c8ce825b03b","lab_id":"69ad52a3de79e566650fb1d5","country":"PL","accr_number":"AB 361","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 27 MHz","range":"do 6 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 27 MHz","range":"do 6 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 6 GHz\n(z obliczeń)","reference":"Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","norm_bases":["Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 6 GHz\n(z obliczeń) Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary selektywne) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 27 MHz do 6 GHz\n(z obliczen) Punkt. 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (selective measurements) Magnetic field strength: in the frequency range from 27 MHz (calculated) Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 27 MHz 起","range":"do 6 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 27 MHz 起 （计算得出） Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz. U. 2022 poz. 1121)"}],"has_pdf":true}