🇵🇱 INSTYTUT MEDYCYNY PRACY PL
EnvironmentElectronics & EMCMaterials & polymers
INSTYTUT MEDYCYNY PRACY is a laboratory accredited by PCA under number AB 327 (Łódź, Poland). Its accreditation scope covers 70 test methods in the following areas: Environment, Electronics & EMC, Materials & polymers. Test objects include: Dosimeters in an ionising radiation field, Workplace environment − noise, Workplace environment - air, Workplace environment − air. Most frequently used techniques: Direct measurement method, Thermoluminescence dosimetry method (TLD), Phase-contrast optical microscopy method.
At a glance
- Accreditation number: PCA AB 327
- Methods in scope: 70
- Types of test objects: 24
- Techniques used: 14
- City: Łódź, Poland
- Accreditation number
- AB 327
- Accreditation body
- PCA
- Address
- IM. PROF. DR MED. JERZEGO NOFERA, ul. Św. Teresy od Dzieciątka Jezus 8, 91-348 Łódź
- City
- Łódź, Poland
What this laboratory tests (24)
- Dosimeters in an ionising radiation field — 6 methods
- Workplace environment − noise — 5 methods
- Workplace environment - air — 4 methods
- Workplace environment − air — 4 methods
- Workplace environment − electromagnetic field from industrial installations and equipment: − arc welding equipment − resistance welding machines − industrial magnetisers and demagnetisers − electrolytic installations − NMR spectrometers − dielectric heating equipment − induction heating equipment − industrial microwave furnaces, heaters and dryers, − equipment for the production and processing of plastics − electric vehicles − soldering equipment − electrical discharge machines − resistance and arc furnaces − electric generators and motors − inverters − special equipment: DIY, new technology devices — 4 methods
- Workplace environment − electromagnetic field originating from equipment used in medical technology: − physiotherapeutic diathermy − magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: − handheld radiotelephones, mobile and cordless telephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) − anti-theft and electronic article surveillance systems — 4 methods
- Workplace environment − hand-arm vibration — 4 methods
- Workplace environment − ultrasonic noise — 4 methods
- Workplace environment − whole-body vibration — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems, mobile telephony base stations) — 3 methods
- Workplace environment − infrasonic noise — 3 methods
- Biological material E — 2 methods
- Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry — 2 methods
- and 9 more
Analytical techniques used (14)
- Direct measurement method — 21 methods
- Thermoluminescence dosimetry method (TLD) — 5 methods
- Phase-contrast optical microscopy method — 4 methods
- Gas chromatography with mass spectrometry detection (GC-MS) — 3 methods
- Personal dosimetry method — 3 methods
- High-performance liquid chromatography with tandem mass spectrometry detection (HPLC-MS/MS) — 2 methods
- Track detector method — 2 methods
- Direct measurement method (simplified) — 1 method
- Electrothermal atomization atomic absorption spectrometry (ETAAS) — 1 method
- Gas chromatography with mass spectrometry detection (GC-MS) using mass spectral libraries — 1 method
- High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) — 1 method
- Inductively coupled plasma mass spectrometry (ICP-MS) — 1 method
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 1 method
- Photometric dosimetry method — 1 method
Accreditation scope — test methods (70)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Dosimeters in an ionising radiation field | Personal dose equivalent Hp(10) of photon radiation Range (0,1 − 1000) mSv |
Photometric dosimetry method | ZRZ-PB-01 wydanie 5 z dnia 01.07.2020 r. | |
| 2 | Dosimeters in an ionising radiation field | Personal dose equivalent Hp(0,07) of photon radiation – ring dosimetry Range (0,05 − 5000) mSv |
Thermoluminescence dosimetry method (TLD) | ZRZ-PB-05 wydanie 5 z dnia 19.07.2023 r. | |
| 3 | Dosimeters in an ionising radiation field | Personal dose equivalent Hp(0,07) of photon radiation – wrist dosimetry Range (0,05 − 5000) mSv |
Thermoluminescence dosimetry method (TLD) | ZRZ-PB-04 wydanie 1 z dnia 01.09.2021 r. | |
| 4 | Dosimeters in an ionising radiation field | Personal dose equivalent Hp(10) of photon radiation Range (0,1 − 10000) mSv |
Thermoluminescence dosimetry method (TLD) | ZRZ-PB-02 wydanie 2 z dnia 01.09.2021 r. | |
| 5 | Dosimeters in an ionising radiation field | Ambient dose equivalent H*(10) of photon radiation Range (0,005 − 1000) mSv |
Thermoluminescence dosimetry method (TLD) | ZRZ-PB-02 wydanie 2 z dnia 01.09.2021 r. | |
| 6 | Dosimeters in an ionising radiation field | Personal dose equivalent Hp(3) of photon radiation Range (0,02 − 50) mSv |
Thermoluminescence dosimetry method (TLD) | ZRZ-PB-03 wydanie 2 z dnia 19.07.2023 r. | |
| 7 | Workplace environment – air, General environment – air, Rooms – air | Radon isotope 222Rn concentration, Range for 1 month detector exposure: (36 – 22222) Bq/m-3 | Track detector method | ZRW-PB-02 wydanie 3 z dnia 22.07.2025 r. | |
| 8 | Workplace environment – air, General environment – air, Rooms – air | Radon isotope 222Rn concentration, Range for any detector exposure time: (26 – 16000) kBq∙h∙m-3 divided by the detector exposure time expressed in hours. | Track detector method | ZRW-PB-02 wydanie 3 z dnia 22.07.2025 r. | |
| 9 | Workplace environment − electromagnetic field from industrial installations and equipment: − arc welding equipment − resistance welding machines − industrial magnetisers and demagnetisers − electrolytic installations − NMR spectrometers − dielectric heating equipment − induction heating equipment − industrial microwave furnaces, heaters and dryers, − equipment for the production and processing of plastics − electric vehicles − soldering equipment − electrical discharge machines − resistance and arc furnaces − electric generators and motors − inverters − special equipment: DIY, new technology devices | Electric field strength: in the frequency range from 20 Hz do 100 kHz Range 2 V/m – 25 kV/m in the frequency range from 10 kHz do 30 MHz Range 0,3 V/m – 1000 V/m in the frequency range from 0,1 MHz do 300 MHz Range 0,8 V/m – 400 V/m in the frequency range from 3 MHz do 5 GHz Range 0,8 V/m – 500 V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 10 | Workplace environment − electromagnetic field from industrial installations and equipment: − arc welding equipment − resistance welding machines − industrial magnetisers and demagnetisers − electrolytic installations − NMR spectrometers − dielectric heating equipment − induction heating equipment − industrial microwave furnaces, heaters and dryers, − equipment for the production and processing of plastics − electric vehicles − soldering equipment − electrical discharge machines − resistance and arc furnaces − electric generators and motors − inverters − special equipment: DIY, new technology devices | Magnetic flux density: in the frequency range 0 Hz Range 0,1 mT – 1000 mT in the frequency range from 5 Hz do 100 kHz Range 0,5 μT – 10 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 11 | Workplace environment − electromagnetic field from industrial installations and equipment: − arc welding equipment − resistance welding machines − industrial magnetisers and demagnetisers − electrolytic installations − NMR spectrometers − dielectric heating equipment − induction heating equipment − industrial microwave furnaces, heaters and dryers, − equipment for the production and processing of plastics − electric vehicles − soldering equipment − electrical discharge machines − resistance and arc furnaces − electric generators and motors − inverters − special equipment: DIY, new technology devices | Magnetic field strength: in the frequency range from 10 kHz do 30 MHz Range 10 mA/m – 200 A/m in the frequency range from 0,1 MHz do 1 GHz Range 10 mA/m – 1,5 A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 12 | Workplace environment − electromagnetic field from industrial installations and equipment: − arc welding equipment − resistance welding machines − industrial magnetisers and demagnetisers − electrolytic installations − NMR spectrometers − dielectric heating equipment − induction heating equipment − industrial microwave furnaces, heaters and dryers, − equipment for the production and processing of plastics − electric vehicles − soldering equipment − electrical discharge machines − resistance and arc furnaces − electric generators and motors − inverters − special equipment: DIY, new technology devices | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 20 Hz do 100 kHz in the frequency range from 800 MHz do 5 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | ||
| 13 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: − handheld radiotelephones, mobile and cordless telephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) − anti-theft and electronic article surveillance systems | Electric field strength: in the frequency range from 20 Hz do 100 kHz Range 2 V/m – 25 kV/m in the frequency range from 10 kHz do 30 MHz Range 0,3 V/m – 1000 V/m in the frequency range from 0,1 MHz do 300 MHz Range 0,8 V/m – 400 V/m in the frequency range from 3 MHz do 5 GHz Range 0,8 V/m – 500 V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 14 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: − handheld radiotelephones, mobile and cordless telephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) − anti-theft and electronic article surveillance systems | Magnetic flux density: in the frequency range 0 Hz Range 0,1 mT – 1000 mT in the frequency range from 5 Hz do 100 kHz Range 0,5 μT – 10 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 15 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: − handheld radiotelephones, mobile and cordless telephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) − anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 10 kHz do 30 MHz Range 10 mA/m – 200 A/m in the frequency range from 0,1 MHz do 1 GHz Range 10 mA/m – 1,5 A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 16 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: − handheld radiotelephones, mobile and cordless telephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) − anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 20 Hz do 100 kHz in the frequency range from 800 MHz do 5 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | ||
| 17 | Workplace environment − electromagnetic field originating from equipment used in medical technology: − physiotherapeutic diathermy − magnetic resonance scanners | Electric field strength: in the frequency range from 20 Hz do 100 kHz Range 2 V/m – 25 kV/m in the frequency range from 10 kHz do 30 MHz Range 0,3 V/m – 1000 V/m in the frequency range from 0,1 MHz do 300 MHz Range 0,8 V/m – 400 V/m in the frequency range from 3 MHz do 5 GHz Range 0,8 V/m – 500 V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 18 | Workplace environment − electromagnetic field originating from equipment used in medical technology: − physiotherapeutic diathermy − magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range 0,1 mT – 1000 mT in the frequency range from 5 Hz do 100 kHz Range 0,5 μT – 10 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 19 | Workplace environment − electromagnetic field originating from equipment used in medical technology: − physiotherapeutic diathermy − magnetic resonance scanners | Magnetic field strength: in the frequency range from 10 kHz do 30 MHz Range 10 mA/m – 200 A/m in the frequency range from 0,1 MHz do 1 GHz Range 10 mA/m – 1,5 A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | |
| 20 | Workplace environment − electromagnetic field originating from equipment used in medical technology: − physiotherapeutic diathermy − magnetic resonance scanners | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 20 Hz do 100 kHz in the frequency range from 800 MHz do 5 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r. | ||
| 21 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range from 45Hz do 55 Hz Range (100 − 25 000) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 | |
| 22 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 45 Hz do 55 Hz Range 0,5 μT − 10 mT |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 | |
| 23 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density: in the frequency range from 20 Hz do 50 Hz Range 0,5 μT − 10 mT |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
| 24 | Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems, mobile telephony base stations) | Electric field strength: in the frequency range from 200 kHz do 250 kHz Range (0,3 - 1000) V/m in the frequency range from 75 MHz do 5 GHz Range (0,8 - 500) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 2 (92), s. 89 - 131 | |
| 25 | Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems, mobile telephony base stations) | Magnetic field strength: in the frequency range: from 200 kHz do 250 kHz Range (0,05 − 200) A/m in the frequency range from 75 MHz do 800 MHz Range (0,012 − 10) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 2 (92), s. 89 - 131 | |
| 26 | Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems, mobile telephony base stations) | Magnetic field strength: in the frequency range from 800 MHz do 5 GHz (calculated) |
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 2 (92), s. 89 - 131 | ||
| 27 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (100 − 25 000) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz.U. 2022, poz. 1121) | |
| 28 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range 0,5 μT − 10 mT |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz.U. 2022, poz. 1121) | |
| 29 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength, In the frequency range 50Hz (calculated) | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz.U. 2022, poz. 1121) | ||
| 30 | Workplace environment − noise | PN-N-01307:1994 | PN-EN ISO 9612:2011 | |||
| 31 | Workplace environment − noise | A-weighted equivalent sound pressure level | PN-N-01307:1994 | PN-EN ISO 9612:2011 | ||
| 32 | Workplace environment − noise | Maximum A-weighted sound pressure level Range (24 − 137) dB |
PN-N-01307:1994 | PN-EN ISO 9612:2011 | ||
| 33 | Workplace environment − noise | C-weighted peak sound pressure level Range (35 − 140) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 | |
| 34 | Workplace environment − noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 | ||
| 35 | Workplace environment − infrasonic noise | PN-Z-01338:2010 | |||
| 36 | Workplace environment − infrasonic noise | G-weighted equivalent sound pressure level Range (28 − 136) dB |
Direct measurement method | PN-Z-01338:2010 | |
| 37 | Workplace environment − infrasonic noise | G-weighted equivalent sound pressure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01338:2010 | ||
| 38 | Workplace environment − ultrasonic noise | PN-Z-01339:2020-12 | |||
| 39 | Workplace environment − ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz | PN-Z-01339:2020-12 | ||
| 40 | Workplace environment − ultrasonic noise | Maximum sound pressure level in third-octave bands with centre frequencies from 10 kHz to 40 kHz Range (45-150) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 41 | Workplace environment − ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01339:2020-12 | ||
| 42 | Workplace environment − hand-arm vibration | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |||
| 43 | Workplace environment − hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,05 – 150) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 44 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 45 | Workplace environment − hand-arm vibration | Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 46 | Workplace environment − whole-body vibration | PN-EN 14253+A1:2011 | |||
| 47 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,005 − 150) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 48 | Workplace environment − whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) | PN-EN 14253+A1:2011 | ||
| 49 | Workplace environment − whole-body vibration | Exposure lasting 30 minutes or less, expressed as the frequency-weighted r.m.s. vibration acceleration, dominant among the vibration accelerations determined for the three directional components with the appropriate factors applied (1,4awx, 1,4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 50 | Workplace environment – noise (selection of hearing protectors) | Equivalent sound pressure level in octave frequency bands Range (63 – 8000) Hz Range (41– 125) dB A-weighted equivalent sound pressure level C-weighted equivalent sound pressure level Range (24 – 137) dB |
Direct measurement method | PN-EN ISO 9612:2011 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 ZZH-PB-05 wydanie 5 z 15.01.2021 r. | |
| 51 | Workplace environment – noise (selection of hearing protectors) | A-weighted equivalent sound level under hearing protectors (calculated) | PN-EN ISO 9612:2011 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 ZZH-PB-05 wydanie 5 z 15.01.2021 r. | ||
| 52 | Workplace environment - air | Sampling for the assessment of occupational exposure to: asbestos – respirable fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres |
Personal dosimetry method | PN-Z-04008-7:2002 | |
| 53 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002 | ||
| 54 | Workplace environment - air | Asbestos concentration – respirable fibres Range (0,0012 – 2,1) wł./cm3 |
Phase-contrast optical microscopy method | PN-88/Z-04202/02 | |
| 55 | Workplace environment - air | Concentration of man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres Range (0,0012 – 2,1) wł./cm3 |
Phase-contrast optical microscopy method | ZSA-PB-2 wydanie 5 z 15.01.2021 r. | |
| 56 | Workplace environment – air samples collected on filters | Asbestos content – respirable fibres Range (882 - 720000) włókien w próbce |
Phase-contrast optical microscopy method | PN-88/Z-04202/02 | |
| 57 | Workplace environment – air samples collected on filters | Content of man-made mineral fibres, except refractory ceramic fibres – respirable fibres Range (882 - 720000) włókien w próbce |
Phase-contrast optical microscopy method | ZSA-PB-2 wydanie 5 z 15.01.2021 r. | |
| 58 | Workplace environment − air | Sampling for the assessment of occupational exposure to: organic substances, including inhalable fraction inorganic substances, including inhalable fraction |
Personal dosimetry method | PN-Z-04008-7:2002 + Az1:2004 | |
| 59 | Workplace environment − air | Sampling for occupational exposure assessment to metals and their compounds, including: inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002 + Az1:2004 | |
| 60 | Workplace environment − air | Exposure index (calculated) | PN-Z-04008-7:2002 + Az1:2004 | ||
| 61 | Workplace environment − air | Concentration / content of halogenated anaesthetics desflurane Range (0,2 – 250) mg/m3 Range (0,001 – 0,95) mg w próbce sevoflurane, isoflurane, halothane Range (0,2 – 190) mg/m3 Range (0,001 – 0,95) mg w próbce |
Gas chromatography with mass spectrometry detection (GC-MS) | CL-PB-09 wydanie 6 z dnia 03.01.2022 r. | |
| 62 | Workplace environmentE - air - air samples collected on sorbent tubes | Concentration of organic substances, Content of organic substances | Gas chromatography with mass spectrometry detection (GC-MS) | Procedury badawcze, normy, Podstawy i Metody Oceny Środowiska Pracy | |
| 63 | Workplace environmentE - air | Concentration of low-boiling substances | Gas chromatography with mass spectrometry detection (GC-MS) | Procedury badawcze, normy, Podstawy i Metody Oceny Środowiska Pracy | |
| 64 | Workplace environmentE - air - air samples collected on filters | Concentration/ content of cytostatics | High-performance liquid chromatography with tandem mass spectrometry detection (HPLC-MS/MS) | Procedury badawcze, normy, Podstawy i Metody Oceny Środowiska Pracy | |
| 65 | Workplace environmentE - air - air samples collected on filters | Concentration / content of metals and their compounds | Inductively coupled plasma optical emission spectrometry (ICP-OES) | CL-PB-15 | |
| 66 | Workplace environmentE - air - air samples collected on sorbent tubes | Identification of organic substances | Gas chromatography with mass spectrometry detection (GC-MS) using mass spectral libraries | CL-PB-21 | |
| 67 | Workplace environmentE - air - air samples collected on sorbent tubes or filters | Concentration / content of organic substances | High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) | Procedury badawcze, normy, Podstawy i Metody Oceny Środowiska Pracy | |
| 68 | Biological material E | Metabolite concentration | High-performance liquid chromatography with tandem mass spectrometry detection (HPLC-MS/MS) | Procedury badawcze | |
| 69 | Biological material E | Metal concentrations | Inductively coupled plasma mass spectrometry (ICP-MS) | Procedury badawcze | |
| 70 | Blood E | Metal concentrations | Electrothermal atomization atomic absorption spectrometry (ETAAS) | Procedury badawcze | |
Reference standards (31)
CL-PB-09 wydanie 6 z dnia 03.01.2022 r.
CL-PB-15
CL-PB-21
Instrukcja ZRE-IR-5 wydanie 1 z dnia 15.02.2021 r.
PN-88/Z-04202/02
PN-EN 14253+A1:2011
PN-EN 458:2016-06
PN-EN ISO 4869-2:2018-12 ZZH-PB-05 wydanie 5 z 15.01.2021 r.
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011
PN-N-01307:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
PN-Z-01338:2010
PN-Z-01339:2020-12
PN-Z-04008-7:2002
PN-Z-04008-7:2002 + Az1:2004
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 2 (92), s. 89 - 131
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
Procedury badawcze
Procedury badawcze, normy, Podstawy i Metody Oceny Środowiska Pracy
ZRW-PB-02 wydanie 3 z dnia 22.07.2025 r.
ZRZ-PB-01 wydanie 5 z dnia 01.07.2020 r.
ZRZ-PB-02 wydanie 2 z dnia 01.09.2021 r.
ZRZ-PB-03 wydanie 2 z dnia 19.07.2023 r.
ZRZ-PB-04 wydanie 1 z dnia 01.09.2021 r.
ZRZ-PB-05 wydanie 5 z dnia 19.07.2023 r.
ZSA-PB-2 wydanie 5 z 15.01.2021 r.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2020 poz. 258, Dz.U. 2022, poz. 1121)