🇵🇱 CENTRALNA STACJA RATOWNICTWA GÓRNICZEGO S.A. PL
Environment
CENTRALNA STACJA RATOWNICTWA GÓRNICZEGO S.A. is a laboratory accredited by PCA under number AB 321 (Bytom, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment. Test objects include: Self-contained closed-circuit breathing apparatus with compressed o…, Closed-circuit escape breathing apparatus, Self-contained compressed air breathing apparatus.
At a glance
- Accreditation number: PCA AB 321
- Methods in scope: 22
- Types of test objects: 3
- City: Bytom, Poland
- Accreditation number
- AB 321
- Accreditation body
- PCA
- Address
- LABORATORIUM BADANIA i OPINIOWANIA SPRZĘTU, ul. Chorzowska 25, 41-902 Bytom
- City
- Bytom, Poland
What this laboratory tests (3)
- Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen — 10 methods
- Closed-circuit escape breathing apparatus — 9 methods
- Self-contained compressed air breathing apparatus — 3 methods
Accreditation scope — test methods (22)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Leak tightness Range (-1000÷1000) Pa |
PN-EN 145: 2000 pkt. 7.7 | ||
| 2 | Closed-circuit escape breathing apparatus | Leak tightness Range (-1000÷1000) Pa |
PN-EN 13794:2005 pkt. 7.5.1; 7.5.2 | ||
| 3 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Gas supply Range (0,5÷120) dm3/min. |
PN-EN 145:2000 pkt. 7.7 | ||
| 4 | Closed-circuit escape breathing apparatus | Oxygen supply Range (0,5÷120) dm3/min. |
PN-EN 13794:2005 pkt. 7.14 | ||
| 5 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Relief valve opening pressure Range (0÷5000) Pa |
PN-EN 145:2000 pkt. 7.12 | ||
| 6 | Closed-circuit escape breathing apparatus | Relief valve opening pressure Range (0÷5000) Pa |
PN-EN 13794:2005 pkt. 7.7 | ||
| 7 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Operation of the feed valve Range (0,5÷120) dm3/min. |
PN-EN 145:2000 pkt. 7.7 | ||
| 8 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Properties of the pressure indicator Range (0÷30) MPa |
PN-EN 145:2000 pkt. 6.18 (bez badań eksploatacyjnych) | ||
| 9 | Closed-circuit escape breathing apparatus | Breathing resistance Range (-5000÷5000) Pa |
PN-EN 13794:2005 pkt. 7.12, pkt. 7.10 | ||
| 10 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Breathing bag volume Range od 0 dm 3 |
PN-EN 145:2000 pkt. 7.13 | ||
| 11 | Closed-circuit escape breathing apparatus | Breathing bag volume Range od 0 dm 3 |
PN-EN 13794:2005 pkt. 7.8 | ||
| 12 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Mass of the apparatus Range (0÷150) kg |
PN-EN 145:2000 pkt. 6.4 | ||
| 13 | Closed-circuit escape breathing apparatus | Mass of the apparatus Range (0÷150) kg |
PN-EN 13794:2005 pkt. 6.5 | ||
| 14 | Self-contained compressed air breathing apparatus | Mass of the apparatus Range (0÷150) kg |
PN-EN 137:2008 pkt. 6.6 | ||
| 15 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Physiological parameters CO2 Range (0÷10) % obj. O2 Range (0÷100) % obj. Temperature Range (0÷120) 0C Breathing resistance Range (-5000÷5000) Pa Flushing device |
PN-EN 145:2000 +A1:2002 pkt. 7.8 | PN-EN 145:2000 pkt. 7.8.1 | PN-EN 145:2000 pkt. 6.22 | ||
| 16 | Closed-circuit escape breathing apparatus | CO2 operating efficiency Range (0÷10) % obj. O2 Range (0÷100) % obj. Temperature Range (0÷120) 0C Breathing resistance Range (-5000÷5000) Pa |
PN-EN 13794:2005 pkt. 7.10 | ||
| 17 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Performance tests | PN-EN 145:2000 pkt. 7.3 | ||
| 18 | Closed-circuit escape breathing apparatus | Performance tests | PN-EN 13794:2005 pkt. 7.16, Załącznik A | ||
| 19 | Self-contained compressed air breathing apparatus | Performance tests | PN-EN 137:2008 pkt. 7.11 | ||
| 20 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Thermal resistance | PN-EN 145:2000 pkt. 7.4 | ||
| 21 | Closed-circuit escape breathing apparatus | Thermal resistance | PN-EN 13794:2005 pkt. 7.9 | ||
| 22 | Self-contained compressed air breathing apparatus | Thermal resistance | PN-EN 137:2008 pkt. 7.4.1.1.; 7.4.1.2; 7.4.2 | ||
Reference standards (23)
PN-EN 13794:2005 pkt. 6.5
PN-EN 13794:2005 pkt. 7.10
PN-EN 13794:2005 pkt. 7.12, pkt. 7.10
PN-EN 13794:2005 pkt. 7.14
PN-EN 13794:2005 pkt. 7.16, Załącznik A
PN-EN 13794:2005 pkt. 7.5.1; 7.5.2
PN-EN 13794:2005 pkt. 7.7
PN-EN 13794:2005 pkt. 7.8
PN-EN 13794:2005 pkt. 7.9
PN-EN 137:2008 pkt. 6.6
PN-EN 137:2008 pkt. 7.11
PN-EN 137:2008 pkt. 7.4.1.1.; 7.4.1.2; 7.4.2
PN-EN 145: 2000 pkt. 7.7
PN-EN 145:2000 +A1:2002 pkt. 7.8
PN-EN 145:2000 pkt. 6.18 (bez badań eksploatacyjnych)
PN-EN 145:2000 pkt. 6.22
PN-EN 145:2000 pkt. 6.4
PN-EN 145:2000 pkt. 7.12
PN-EN 145:2000 pkt. 7.13
PN-EN 145:2000 pkt. 7.3
PN-EN 145:2000 pkt. 7.4
PN-EN 145:2000 pkt. 7.7
PN-EN 145:2000 pkt. 7.8.1