🇵🇱 CENTRALNA STACJA RATOWNICTWA GÓRNICZEGO S.A. PL

PCA AB 321 • Bytom, Poland • 22 methods

Environment

CENTRALNA STACJA RATOWNICTWA GÓRNICZEGO S.A. is a laboratory accredited by PCA under number AB 321 (Bytom, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment. Test objects include: Self-contained closed-circuit breathing apparatus with compressed o…, Closed-circuit escape breathing apparatus, Self-contained compressed air breathing apparatus.

At a glance

  • Accreditation number: PCA AB 321
  • Methods in scope: 22
  • Types of test objects: 3
  • City: Bytom, Poland
Accreditation number
AB 321
Accreditation body
PCA
Address
LABORATORIUM BADANIA i OPINIOWANIA SPRZĘTU, ul. Chorzowska 25, 41-902 Bytom
City
Bytom, Poland

What this laboratory tests (3)

Accreditation scope — test methods (22)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Leak tightness
Range (-1000÷1000) Pa
PN-EN 145: 2000 pkt. 7.7
2 Closed-circuit escape breathing apparatus Leak tightness
Range (-1000÷1000) Pa
PN-EN 13794:2005 pkt. 7.5.1; 7.5.2
3 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Gas supply
Range (0,5÷120) dm3/min.
PN-EN 145:2000 pkt. 7.7
4 Closed-circuit escape breathing apparatus Oxygen supply
Range (0,5÷120) dm3/min.
PN-EN 13794:2005 pkt. 7.14
5 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Relief valve opening pressure
Range (0÷5000) Pa
PN-EN 145:2000 pkt. 7.12
6 Closed-circuit escape breathing apparatus Relief valve opening pressure
Range (0÷5000) Pa
PN-EN 13794:2005 pkt. 7.7
7 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Operation of the feed valve
Range (0,5÷120) dm3/min.
PN-EN 145:2000 pkt. 7.7
8 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Properties of the pressure indicator
Range (0÷30) MPa
PN-EN 145:2000 pkt. 6.18 (bez badań eksploatacyjnych)
9 Closed-circuit escape breathing apparatus Breathing resistance
Range (-5000÷5000) Pa
PN-EN 13794:2005 pkt. 7.12, pkt. 7.10
10 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Breathing bag volume
Range od 0 dm 3
PN-EN 145:2000 pkt. 7.13
11 Closed-circuit escape breathing apparatus Breathing bag volume
Range od 0 dm 3
PN-EN 13794:2005 pkt. 7.8
12 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Mass of the apparatus
Range (0÷150) kg
PN-EN 145:2000 pkt. 6.4
13 Closed-circuit escape breathing apparatus Mass of the apparatus
Range (0÷150) kg
PN-EN 13794:2005 pkt. 6.5
14 Self-contained compressed air breathing apparatus Mass of the apparatus
Range (0÷150) kg
PN-EN 137:2008 pkt. 6.6
15 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Physiological parameters CO2
Range (0÷10) % obj. O2 Range (0÷100) % obj. Temperature Range (0÷120) 0C Breathing resistance Range (-5000÷5000) Pa Flushing device
PN-EN 145:2000 +A1:2002 pkt. 7.8 | PN-EN 145:2000 pkt. 7.8.1 | PN-EN 145:2000 pkt. 6.22
16 Closed-circuit escape breathing apparatus CO2 operating efficiency
Range (0÷10) % obj. O2 Range (0÷100) % obj. Temperature Range (0÷120) 0C Breathing resistance Range (-5000÷5000) Pa
PN-EN 13794:2005 pkt. 7.10
17 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Performance tests PN-EN 145:2000 pkt. 7.3
18 Closed-circuit escape breathing apparatus Performance tests PN-EN 13794:2005 pkt. 7.16, Załącznik A
19 Self-contained compressed air breathing apparatus Performance tests PN-EN 137:2008 pkt. 7.11
20 Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen Thermal resistance PN-EN 145:2000 pkt. 7.4
21 Closed-circuit escape breathing apparatus Thermal resistance PN-EN 13794:2005 pkt. 7.9
22 Self-contained compressed air breathing apparatus Thermal resistance PN-EN 137:2008 pkt. 7.4.1.1.; 7.4.1.2; 7.4.2

Reference standards (23)

PN-EN 13794:2005 pkt. 6.5
PN-EN 13794:2005 pkt. 7.10
PN-EN 13794:2005 pkt. 7.12, pkt. 7.10
PN-EN 13794:2005 pkt. 7.14
PN-EN 13794:2005 pkt. 7.16, Załącznik A
PN-EN 13794:2005 pkt. 7.5.1; 7.5.2
PN-EN 13794:2005 pkt. 7.7
PN-EN 13794:2005 pkt. 7.8
PN-EN 13794:2005 pkt. 7.9
PN-EN 137:2008 pkt. 6.6
PN-EN 137:2008 pkt. 7.11
PN-EN 137:2008 pkt. 7.4.1.1.; 7.4.1.2; 7.4.2
PN-EN 145: 2000 pkt. 7.7
PN-EN 145:2000 +A1:2002 pkt. 7.8
PN-EN 145:2000 pkt. 6.18 (bez badań eksploatacyjnych)
PN-EN 145:2000 pkt. 6.22
PN-EN 145:2000 pkt. 6.4
PN-EN 145:2000 pkt. 7.12
PN-EN 145:2000 pkt. 7.13
PN-EN 145:2000 pkt. 7.3
PN-EN 145:2000 pkt. 7.4
PN-EN 145:2000 pkt. 7.7
PN-EN 145:2000 pkt. 7.8.1