🇵🇱 INSTYTUT KOLEJNICTWA PL

PCA AB 310 • Warszawa, Poland • 79 methods

Electronics & EMCEnvironmentAutomotive

INSTYTUT KOLEJNICTWA is a laboratory accredited by PCA under number AB 310 (Warszawa, Poland). Its accreditation scope covers 79 test methods in the following areas: Electronics & EMC, Environment, Automotive. Test objects include: Electronic products and equipment mounted on railway rolling stock, Electrical, telecommunications and electronic products and equipment, Electrical, telecommunications and electronic products and equipmen…, Railway traffic control and telecommunications equipment. Most frequently used techniques: Direct method, Method: Test A, Method: Test B.

At a glance

  • Accreditation number: PCA AB 310
  • Methods in scope: 79
  • Types of test objects: 23
  • Techniques used: 7
  • City: Warszawa, Poland
Accreditation number
AB 310
Accreditation body
PCA
Address
LABORATORIUM AUTOMATYKI I TELEKOMUNIKACJI, ul. J. Chłopickiego 50, 04-275 Warszawa
City
Warszawa, Poland

What this laboratory tests (23)

Analytical techniques used (7)

Accreditation scope — test methods (79)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Railway rail vehicles: - automatic train braking device SHP
Functions related to the SHP device during the passage of a traction vehicle over track resonators Recordings of events related to spot track-vehicle interaction
PB-LA-18 wersja 6 z dnia 28.07.2017 r.
2 Railway rail vehicles: - active vigilance device CA
Performance of functions related to the cyclic operation of the CA device while the traction vehicle is running Recordings of the cyclic operation of the CA device
PB-LA-19 wersja 6 z dnia 28.07.2017 r.
3 Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock Dielectric strength of the insulation
Range do 5 kV AC, do 6 kV DC
Direct method PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
4 Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock Insulation resistance with a value from 250 kΩ to 1100 GΩ. Direct method PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
5 Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Immunity and resistance to cold (down to - 60 oC) Method: Test A PN-EN 60068-2-1:2009
6 Electronic products and equipment mounted on railway rolling stock Immunity and resistance to cold (down to - 60 oC) Method: Test A PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06
7 Signalling and telecommunications equipment Immunity and resistance to cold (down to - 60 oC) Method: Test A PN-EN 50125-3:2003
8 Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Immunity and resistance to dry heat (up to + 150 oC) Method: Test B PN-EN 60068-2-2:2009
9 Electronic products and equipment mounted on railway rolling stock Immunity and resistance to dry heat (up to + 150 oC) Method: Test B PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06
10 Signalling and telecommunications equipment Immunity and resistance to dry heat (up to + 150 oC) Method: Test B PN-EN 50125-3:2003
11 Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Resistance and endurance to steady damp heat Method: Test Cab PN-EN 60068-2-78:2013-11
12 Signalling and telecommunications equipment Resistance and endurance to steady damp heat Method: Test Cab PN-EN 50125-3:2003
13 Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Immunity and resistance to cyclic damp heat Method: Test Db PN-EN 60068-2-30:2008
14 Electronic products and equipment mounted on railway rolling stock Immunity and resistance to cyclic damp heat Method: Test Db PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06
15 Signalling and telecommunications equipment Immunity and resistance to cyclic damp heat Method: Test Db PN-EN 50125-3:2003
16 Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Resistance and endurance of products to change of temperature Method: Test Nb PN-EN 60068-2-14:2024-04
17 Signalling and telecommunications equipment Resistance and endurance of products to change of temperature Method: Test Nb PN-EN 50125-3:2003
18 Electronic products and equipment mounted on railway rolling stock Resistance to simulated solar radiation occurring at the earth's surface Method: Test Sa PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3
19 Stationary electrical equipment Resistance to simulated solar radiation occurring at the earth's surface Method: Test Sa PN-EN 50125-2:2003 wg pkt 4.8 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3
20 Signalling and telecommunications equipment Resistance to simulated solar radiation occurring at the earth's surface Method: Test Sa PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3
21 Electrical, telecommunications and electronic products and equipment Immunity to electrostatic discharge
discharges (0,5 – 30) kV
Direct method PN-EN 61000-4-2:2011
22 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to electrostatic discharge
discharges (0,5 – 30) kV
Direct method PN-EN IEC 61000-6-2:2019-04
23 Electronic products and equipment mounted on railway rolling stock Immunity to electrostatic discharge
discharges (0,5 – 30) kV
Direct method PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
24 Railway traffic control and telecommunications equipment Immunity to electrostatic discharge
discharges (0,5 – 30) kV
Direct method PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
25 Stationary equipment of the power supply system. Immunity to electrostatic discharge
discharges (0,5 – 30) kV
Direct method PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
26 Electrical, telecommunications and electronic products and equipment Immunity to radiated radio-frequency electromagnetic field PN-EN 61000-4-3:2021-06
27 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to radiated radio-frequency electromagnetic field PN-EN IEC 61000-6-2:2019-04
28 Electronic products and equipment mounted on railway rolling stock Immunity to radiated radio-frequency electromagnetic field PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
29 Railway traffic control and telecommunications equipment Immunity to radiated radio-frequency electromagnetic field PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
30 Stationary equipment of the power supply system. Immunity to radiated radio-frequency electromagnetic field PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
31 Electrical, telecommunications and electronic products and equipment Immunity to electrical fast transient bursts 5/50 ns
Range (0,2 – 4,5) kV
Direct method PN-EN 61000-4-4:2013-05
32 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to electrical fast transient bursts 5/50 ns
Range (0,2 – 4,5) kV
Direct method PN-EN IEC 61000-6-2:2019-04
33 Electronic products and equipment mounted on railway rolling stock Immunity to electrical fast transient bursts 5/50 ns
Range (0,2 – 4,5) kV
Direct method PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
34 Railway traffic control and telecommunications equipment Immunity to electrical fast transient bursts 5/50 ns
Range (0,2 – 4,5) kV
Direct method PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
35 Stationary equipment of the power supply system Immunity to electrical fast transient bursts 5/50 ns
Range (0,2 – 4,5) kV
Direct method PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
36 Electrical, telecommunications and electronic products and equipment Immunity to electrical surges (1,2/50 – 8/20) μs
Range (0,2 – 5,5) kV
Direct method PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01
37 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to electrical surges (1,2/50 – 8/20) μs
Range (0,2 – 5,5) kV
Direct method PN-EN IEC 61000-6-2:2019-04
38 Electronic products and equipment mounted on railway rolling stock Immunity to electrical surges (1,2/50 – 8/20) μs
Range (0,2 – 5,5) kV
Direct method PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
39 Railway traffic control and telecommunications equipment Immunity to electrical surges (1,2/50 – 8/20) μs
Range (0,2 – 5,5) kV
Direct method PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
40 Stationary equipment of the power supply system Immunity to electrical surges (1,2/50 – 8/20) μs
Range (0,2 – 5,5) kV
Direct method PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
41 Electrical, telecommunications and electronic products and equipment Immunity to conducted disturbances induced by radio-frequency fields
Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.)
Direct method PN-EN IEC 61000-4-6:2024-03
42 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to conducted disturbances induced by radio-frequency fields
Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.)
Direct method PN-EN IEC 61000-6-2:2019-04
43 Electronic products and equipment mounted on railway rolling stock Immunity to conducted disturbances induced by radio-frequency fields
Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.)
Direct method PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
44 Railway traffic control and telecommunications equipment Immunity to conducted disturbances induced by radio-frequency fields
Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.)
Direct method PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
45 Stationary equipment of the power supply system Immunity to conducted disturbances induced by radio-frequency fields
Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.)
Direct method PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
46 Electrical, telecommunications and electronic products and equipment Immunity to power-frequency magnetic field
Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c.
Direct method PN-EN 61000-4-8:2010
47 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to power-frequency magnetic field
Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c.
Direct method PN-EN IEC 61000-6-2:2019-04
48 Railway traffic control and telecommunications equipment Immunity to power-frequency magnetic field
Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c.
Direct method PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
49 Stationary equipment of the power supply system Immunity to power-frequency magnetic field
Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c.
Direct method PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
50 Industrial and railway installations, power plants, medium- and high-voltage substations Immunity to pulse magnetic field
Range do 1000 A/m
Direct method PN-EN 61000-4-9:2016-11
51 Electrical, telecommunications and electronic products and equipment Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment
Range do 300 V AC, 16 A
Direct method PN-EN IEC 61000-4-11:2020-11
52 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment
Range do 300 V AC, 16 A
Direct method PN-EN IEC 61000-6-2:2019-04
53 Electrical, telecommunications and electronic products and equipment Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment
Range do 425 V DC,
Direct method PN-EN 61000-4-29:2004
54 Electronic products and equipment mounted on railway rolling stock Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment
Range do 425 V DC,
Direct method PN-EN 50155:2018-01 | PN-EN 50155:2022-05
55 Industrial, scientific and medical equipment Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08
56 Electrical, telecommunications and electronic products and equipment Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12
57 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12
58 Electronic products and equipment mounted on railway rolling stock Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05
59 Railway traffic control and telecommunications equipment Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07
60 Stationary equipment of the power supply system Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07
61 Multimedia equipment Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC
Direct method PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
62 Railway and urban rail vehicles and trolleybuses Level of conducted disturbance emission
Frequency range 9 kHz - 30 MHz
Direct method PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025
63 Equipment for railway signalling: Signal lanterns of railway signals Directional luminous intensity, Useful beam angle δ0,5, Light colour chromaticity (0 – 1), Spectral characteristics in the range, UV, VIS and NIR (200 – 1050) nm Instrukcja PKP PLK S.A. Ie-123 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09
64 Equipment for railway signalling: Illuminated railway indicators Chromaticity of light colour (0 – 1), Luminance Instrukcja PKP PLK S.A. Ie-102 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 CIE 015:2018
65 Actuating elements of the Central Dynamic Passenger Information System (CSDIP) and accompanying infrastructure Luminance, Luminance uniformity Instrukcja PKP PLK S.A. Ipi-6 | PN-EN ISO 9241-305:2009
66 Industrial, scientific and medical equipment Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01
67 Electrical, telecommunications and electronic products and equipment Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12
68 Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12
69 Electronic products and equipment mounted on railway rolling stock Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12
70 Railway traffic control and telecommunications equipment Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12
71 Stationary equipment of the power supply system Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12
72 Multimedia equipment Level of radiated disturbance emission
Range 30 MHz – 6 GHz
PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
73 Railway and urban rail vehicles and trolleybuses Level of radiated disturbance emission in the frequency range: 150 kHz – 1 GHz PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06
74 Railway and urban rail vehicles and trolleybuses, railway environment DC magnetic field level
Range 100 μT – 20 T
PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10
75 Railway and urban rail vehicles and trolleybuses, railway environment AC magnetic field level
Range 100 nT – 32 T in the frequency range from 5 Hz do 20 kHz
PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10
76 Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) RF power and ability to operate after climatic exposure PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2 | PB-LA-04 wersja 11 z dnia 20.12.2018 r.
77 Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) Operating time and operating capability at a specified transmit: receive: standby ratio PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2 | PB-LA-05 wersja 9 z dnia 30.03.2016 r.
78 Railway rail vehicles: - radiotelephone with radio-stop function
Performance of functions related to the activation of the radio-stop Recording of events related to the activation of the radio-stop
PB-LA-07 wersja 7 z dnia 28.07.2017 r.
79 Radiocommunication installations along the railway line Electric field strength in the GSM-R band
Range 921 MHz - 960 MHz
PB-LA-17 wersja 4 z 26.04.2023 r.

Reference standards (70)

Instrukcja PKP PLK S.A. Ie-102
Instrukcja PKP PLK S.A. Ie-123
Instrukcja PKP PLK S.A. Ipi-6
PB-LA-04 wersja 11 z dnia 20.12.2018 r.
PB-LA-05 wersja 9 z dnia 30.03.2016 r.
PB-LA-07 wersja 7 z dnia 28.07.2017 r.
PB-LA-12 wersja 7 z dnia 30.05.2012 r.
PB-LA-17 wersja 4 z 26.04.2023 r.
PB-LA-18 wersja 6 z dnia 28.07.2017 r.
PB-LA-19 wersja 6 z dnia 28.07.2017 r.
PB-LA-21 wersja 10 z dnia 29.05.2025
PN-EN 13032-1+A1:2012
PN-EN 13032-4+A1:2019-09
PN-EN 13032-4+A1:2019-09 CIE 015:2018
PN-EN 50121-2:2015-10
PN-EN 50121-2:2017-06
PN-EN 50121-3-1:2017-05
PN-EN 50121-3-1:2017-05/A1:2019-07
PN-EN 50121-3-2:2017-04
PN-EN 50121-3-2:2017-04/A1:2019-07
PN-EN 50121-4:2017-04
PN-EN 50121-4:2017-04/A1:2019-07
PN-EN 50121-5:2017-05
PN-EN 50121-5:2017-05/A1:2019-07
PN-EN 50125-1:2014-06
PN-EN 50125-1:2014-06 wg pkt 4.9
PN-EN 50125-2:2003 wg pkt 4.8
PN-EN 50125-3:2003
PN-EN 50125-3:2003 wg pkt 4.9
PN-EN 50155:2018-01
PN-EN 50155:2022-05
PN-EN 50500:2008
PN-EN 50500:2008/A1:2015-10
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A11:2020-07
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A11:2020-07
PN-EN 55032:2015-09/A1:2021-05
PN-EN 60068-2-14:2024-04
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-78:2013-11
PN-EN 61000-4-29:2004
PN-EN 61000-4-2:2011
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-5:2014-10/A1:2018-01
PN-EN 61000-4-8:2010
PN-EN 61000-4-9:2016-11
PN-EN 61000-6-4:2008
PN-EN 61000-6-4:2008/A1:2012
PN-EN 61180:2016-12
PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3
PN-EN IEC 61000-4-11:2020-11
PN-EN IEC 61000-4-6:2024-03
PN-EN IEC 61000-6-2:2019-04
PN-EN IEC 61000-6-4:2019-12
PN-EN ISO 9241-305:2009
PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2
PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2
PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2
PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2