🇵🇱 INSTYTUT KOLEJNICTWA PL
Electronics & EMCEnvironmentAutomotive
INSTYTUT KOLEJNICTWA is a laboratory accredited by PCA under number AB 310 (Warszawa, Poland). Its accreditation scope covers 79 test methods in the following areas: Electronics & EMC, Environment, Automotive. Test objects include: Electronic products and equipment mounted on railway rolling stock, Electrical, telecommunications and electronic products and equipment, Electrical, telecommunications and electronic products and equipmen…, Railway traffic control and telecommunications equipment. Most frequently used techniques: Direct method, Method: Test A, Method: Test B.
At a glance
- Accreditation number: PCA AB 310
- Methods in scope: 79
- Types of test objects: 23
- Techniques used: 7
- City: Warszawa, Poland
- Accreditation number
- AB 310
- Accreditation body
- PCA
- Address
- LABORATORIUM AUTOMATYKI I TELEKOMUNIKACJI, ul. J. Chłopickiego 50, 04-275 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (23)
- Electronic products and equipment mounted on railway rolling stock — 12 methods
- Electrical, telecommunications and electronic products and equipment — 10 methods
- Electrical, telecommunications and electronic products and equipment intended for use in industrial environments — 9 methods
- Railway traffic control and telecommunications equipment — 8 methods
- Signalling and telecommunications equipment — 6 methods
- Stationary equipment of the power supply system — 6 methods
- Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] — 5 methods
- Industrial, scientific and medical equipment — 2 methods
- Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock — 2 methods
- Multimedia equipment — 2 methods
- Railway and urban rail vehicles and trolleybuses — 2 methods
- Railway and urban rail vehicles and trolleybuses, railway environment — 2 methods
- Stationary equipment of the power supply system. — 2 methods
- Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) — 2 methods
- Actuating elements of the Central Dynamic Passenger Information System (CSDIP) and accompanying infrastructure — 1 method
- and 8 more
Analytical techniques used (7)
- Direct method — 39 methods
- Method: Test A — 3 methods
- Method: Test B — 3 methods
- Method: Test Db — 3 methods
- Method: Test Sa — 3 methods
- Method: Test Cab — 2 methods
- Method: Test Nb — 2 methods
Accreditation scope — test methods (79)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Railway rail vehicles: - automatic train braking device SHP | Functions related to the SHP device during the passage of a traction vehicle over track resonators Recordings of events related to spot track-vehicle interaction |
PB-LA-18 wersja 6 z dnia 28.07.2017 r. | ||
| 2 | Railway rail vehicles: - active vigilance device CA | Performance of functions related to the cyclic operation of the CA device while the traction vehicle is running Recordings of the cyclic operation of the CA device |
PB-LA-19 wersja 6 z dnia 28.07.2017 r. | ||
| 3 | Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock | Dielectric strength of the insulation Range do 5 kV AC, do 6 kV DC |
Direct method | PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 4 | Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock | Insulation resistance with a value from 250 kΩ to 1100 GΩ. | Direct method | PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 5 | Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] | Immunity and resistance to cold (down to - 60 oC) | Method: Test A | PN-EN 60068-2-1:2009 | |
| 6 | Electronic products and equipment mounted on railway rolling stock | Immunity and resistance to cold (down to - 60 oC) | Method: Test A | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06 | |
| 7 | Signalling and telecommunications equipment | Immunity and resistance to cold (down to - 60 oC) | Method: Test A | PN-EN 50125-3:2003 | |
| 8 | Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] | Immunity and resistance to dry heat (up to + 150 oC) | Method: Test B | PN-EN 60068-2-2:2009 | |
| 9 | Electronic products and equipment mounted on railway rolling stock | Immunity and resistance to dry heat (up to + 150 oC) | Method: Test B | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06 | |
| 10 | Signalling and telecommunications equipment | Immunity and resistance to dry heat (up to + 150 oC) | Method: Test B | PN-EN 50125-3:2003 | |
| 11 | Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] | Resistance and endurance to steady damp heat | Method: Test Cab | PN-EN 60068-2-78:2013-11 | |
| 12 | Signalling and telecommunications equipment | Resistance and endurance to steady damp heat | Method: Test Cab | PN-EN 50125-3:2003 | |
| 13 | Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] | Immunity and resistance to cyclic damp heat | Method: Test Db | PN-EN 60068-2-30:2008 | |
| 14 | Electronic products and equipment mounted on railway rolling stock | Immunity and resistance to cyclic damp heat | Method: Test Db | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06 | |
| 15 | Signalling and telecommunications equipment | Immunity and resistance to cyclic damp heat | Method: Test Db | PN-EN 50125-3:2003 | |
| 16 | Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] | Resistance and endurance of products to change of temperature | Method: Test Nb | PN-EN 60068-2-14:2024-04 | |
| 17 | Signalling and telecommunications equipment | Resistance and endurance of products to change of temperature | Method: Test Nb | PN-EN 50125-3:2003 | |
| 18 | Electronic products and equipment mounted on railway rolling stock | Resistance to simulated solar radiation occurring at the earth's surface | Method: Test Sa | PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3 | |
| 19 | Stationary electrical equipment | Resistance to simulated solar radiation occurring at the earth's surface | Method: Test Sa | PN-EN 50125-2:2003 wg pkt 4.8 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3 | |
| 20 | Signalling and telecommunications equipment | Resistance to simulated solar radiation occurring at the earth's surface | Method: Test Sa | PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3 | |
| 21 | Electrical, telecommunications and electronic products and equipment | Immunity to electrostatic discharge discharges (0,5 – 30) kV |
Direct method | PN-EN 61000-4-2:2011 | |
| 22 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to electrostatic discharge discharges (0,5 – 30) kV |
Direct method | PN-EN IEC 61000-6-2:2019-04 | |
| 23 | Electronic products and equipment mounted on railway rolling stock | Immunity to electrostatic discharge discharges (0,5 – 30) kV |
Direct method | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 24 | Railway traffic control and telecommunications equipment | Immunity to electrostatic discharge discharges (0,5 – 30) kV |
Direct method | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | |
| 25 | Stationary equipment of the power supply system. | Immunity to electrostatic discharge discharges (0,5 – 30) kV |
Direct method | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | |
| 26 | Electrical, telecommunications and electronic products and equipment | Immunity to radiated radio-frequency electromagnetic field | PN-EN 61000-4-3:2021-06 | ||
| 27 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to radiated radio-frequency electromagnetic field | PN-EN IEC 61000-6-2:2019-04 | ||
| 28 | Electronic products and equipment mounted on railway rolling stock | Immunity to radiated radio-frequency electromagnetic field | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | ||
| 29 | Railway traffic control and telecommunications equipment | Immunity to radiated radio-frequency electromagnetic field | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | ||
| 30 | Stationary equipment of the power supply system. | Immunity to radiated radio-frequency electromagnetic field | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | ||
| 31 | Electrical, telecommunications and electronic products and equipment | Immunity to electrical fast transient bursts 5/50 ns Range (0,2 – 4,5) kV |
Direct method | PN-EN 61000-4-4:2013-05 | |
| 32 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to electrical fast transient bursts 5/50 ns Range (0,2 – 4,5) kV |
Direct method | PN-EN IEC 61000-6-2:2019-04 | |
| 33 | Electronic products and equipment mounted on railway rolling stock | Immunity to electrical fast transient bursts 5/50 ns Range (0,2 – 4,5) kV |
Direct method | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 34 | Railway traffic control and telecommunications equipment | Immunity to electrical fast transient bursts 5/50 ns Range (0,2 – 4,5) kV |
Direct method | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | |
| 35 | Stationary equipment of the power supply system | Immunity to electrical fast transient bursts 5/50 ns Range (0,2 – 4,5) kV |
Direct method | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | |
| 36 | Electrical, telecommunications and electronic products and equipment | Immunity to electrical surges (1,2/50 – 8/20) μs Range (0,2 – 5,5) kV |
Direct method | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | |
| 37 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to electrical surges (1,2/50 – 8/20) μs Range (0,2 – 5,5) kV |
Direct method | PN-EN IEC 61000-6-2:2019-04 | |
| 38 | Electronic products and equipment mounted on railway rolling stock | Immunity to electrical surges (1,2/50 – 8/20) μs Range (0,2 – 5,5) kV |
Direct method | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 39 | Railway traffic control and telecommunications equipment | Immunity to electrical surges (1,2/50 – 8/20) μs Range (0,2 – 5,5) kV |
Direct method | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | |
| 40 | Stationary equipment of the power supply system | Immunity to electrical surges (1,2/50 – 8/20) μs Range (0,2 – 5,5) kV |
Direct method | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | |
| 41 | Electrical, telecommunications and electronic products and equipment | Immunity to conducted disturbances induced by radio-frequency fields Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.) |
Direct method | PN-EN IEC 61000-4-6:2024-03 | |
| 42 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to conducted disturbances induced by radio-frequency fields Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.) |
Direct method | PN-EN IEC 61000-6-2:2019-04 | |
| 43 | Electronic products and equipment mounted on railway rolling stock | Immunity to conducted disturbances induced by radio-frequency fields Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.) |
Direct method | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 44 | Railway traffic control and telecommunications equipment | Immunity to conducted disturbances induced by radio-frequency fields Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.) |
Direct method | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | |
| 45 | Stationary equipment of the power supply system | Immunity to conducted disturbances induced by radio-frequency fields Frequency range 150 kHz – 230 MHz Level do 30 V (r.m.s.) |
Direct method | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | |
| 46 | Electrical, telecommunications and electronic products and equipment | Immunity to power-frequency magnetic field Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c. |
Direct method | PN-EN 61000-4-8:2010 | |
| 47 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to power-frequency magnetic field Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c. |
Direct method | PN-EN IEC 61000-6-2:2019-04 | |
| 48 | Railway traffic control and telecommunications equipment | Immunity to power-frequency magnetic field Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c. |
Direct method | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | |
| 49 | Stationary equipment of the power supply system | Immunity to power-frequency magnetic field Range 50 Hz, 0 Hz 1000 A/m (r.m.s.) - system a.c. |
Direct method | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | |
| 50 | Industrial and railway installations, power plants, medium- and high-voltage substations | Immunity to pulse magnetic field Range do 1000 A/m |
Direct method | PN-EN 61000-4-9:2016-11 | |
| 51 | Electrical, telecommunications and electronic products and equipment | Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment Range do 300 V AC, 16 A |
Direct method | PN-EN IEC 61000-4-11:2020-11 | |
| 52 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment Range do 300 V AC, 16 A |
Direct method | PN-EN IEC 61000-6-2:2019-04 | |
| 53 | Electrical, telecommunications and electronic products and equipment | Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment Range do 425 V DC, |
Direct method | PN-EN 61000-4-29:2004 | |
| 54 | Electronic products and equipment mounted on railway rolling stock | Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment Range do 425 V DC, |
Direct method | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 55 | Industrial, scientific and medical equipment | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | |
| 56 | Electrical, telecommunications and electronic products and equipment | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | |
| 57 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 | |
| 58 | Electronic products and equipment mounted on railway rolling stock | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | |
| 59 | Railway traffic control and telecommunications equipment | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | |
| 60 | Stationary equipment of the power supply system | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 | |
| 61 | Multimedia equipment | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC |
Direct method | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 | |
| 62 | Railway and urban rail vehicles and trolleybuses | Level of conducted disturbance emission Frequency range 9 kHz - 30 MHz |
Direct method | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025 | |
| 63 | Equipment for railway signalling: Signal lanterns of railway signals | Directional luminous intensity, Useful beam angle δ0,5, Light colour chromaticity (0 – 1), Spectral characteristics in the range, UV, VIS and NIR (200 – 1050) nm | Instrukcja PKP PLK S.A. Ie-123 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 | ||
| 64 | Equipment for railway signalling: Illuminated railway indicators | Chromaticity of light colour (0 – 1), Luminance | Instrukcja PKP PLK S.A. Ie-102 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 CIE 015:2018 | ||
| 65 | Actuating elements of the Central Dynamic Passenger Information System (CSDIP) and accompanying infrastructure | Luminance, Luminance uniformity | Instrukcja PKP PLK S.A. Ipi-6 | PN-EN ISO 9241-305:2009 | ||
| 66 | Industrial, scientific and medical equipment | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | ||
| 67 | Electrical, telecommunications and electronic products and equipment | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 | ||
| 68 | Electrical, telecommunications and electronic products and equipment intended for use in industrial environments | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 | ||
| 69 | Electronic products and equipment mounted on railway rolling stock | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 | ||
| 70 | Railway traffic control and telecommunications equipment | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 | ||
| 71 | Stationary equipment of the power supply system | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 | ||
| 72 | Multimedia equipment | Level of radiated disturbance emission Range 30 MHz – 6 GHz |
PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 | ||
| 73 | Railway and urban rail vehicles and trolleybuses | Level of radiated disturbance emission in the frequency range: 150 kHz – 1 GHz | PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06 | ||
| 74 | Railway and urban rail vehicles and trolleybuses, railway environment | DC magnetic field level Range 100 μT – 20 T |
PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10 | ||
| 75 | Railway and urban rail vehicles and trolleybuses, railway environment | AC magnetic field level Range 100 nT – 32 T in the frequency range from 5 Hz do 20 kHz |
PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10 | ||
| 76 | Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) | RF power and ability to operate after climatic exposure | PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2 | PB-LA-04 wersja 11 z dnia 20.12.2018 r. | ||
| 77 | Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) | Operating time and operating capability at a specified transmit: receive: standby ratio | PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2 | PB-LA-05 wersja 9 z dnia 30.03.2016 r. | ||
| 78 | Railway rail vehicles: - radiotelephone with radio-stop function | Performance of functions related to the activation of the radio-stop Recording of events related to the activation of the radio-stop |
PB-LA-07 wersja 7 z dnia 28.07.2017 r. | ||
| 79 | Radiocommunication installations along the railway line | Electric field strength in the GSM-R band Range 921 MHz - 960 MHz |
PB-LA-17 wersja 4 z 26.04.2023 r. | ||
Reference standards (70)
Instrukcja PKP PLK S.A. Ie-102
Instrukcja PKP PLK S.A. Ie-123
Instrukcja PKP PLK S.A. Ipi-6
PB-LA-04 wersja 11 z dnia 20.12.2018 r.
PB-LA-05 wersja 9 z dnia 30.03.2016 r.
PB-LA-07 wersja 7 z dnia 28.07.2017 r.
PB-LA-12 wersja 7 z dnia 30.05.2012 r.
PB-LA-17 wersja 4 z 26.04.2023 r.
PB-LA-18 wersja 6 z dnia 28.07.2017 r.
PB-LA-19 wersja 6 z dnia 28.07.2017 r.
PB-LA-21 wersja 10 z dnia 29.05.2025
PN-EN 13032-1+A1:2012
PN-EN 13032-4+A1:2019-09
PN-EN 13032-4+A1:2019-09 CIE 015:2018
PN-EN 50121-2:2015-10
PN-EN 50121-2:2017-06
PN-EN 50121-3-1:2017-05
PN-EN 50121-3-1:2017-05/A1:2019-07
PN-EN 50121-3-2:2017-04
PN-EN 50121-3-2:2017-04/A1:2019-07
PN-EN 50121-4:2017-04
PN-EN 50121-4:2017-04/A1:2019-07
PN-EN 50121-5:2017-05
PN-EN 50121-5:2017-05/A1:2019-07
PN-EN 50125-1:2014-06
PN-EN 50125-1:2014-06 wg pkt 4.9
PN-EN 50125-2:2003 wg pkt 4.8
PN-EN 50125-3:2003
PN-EN 50125-3:2003 wg pkt 4.9
PN-EN 50155:2018-01
PN-EN 50155:2022-05
PN-EN 50500:2008
PN-EN 50500:2008/A1:2015-10
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A11:2020-07
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A11:2020-07
PN-EN 55032:2015-09/A1:2021-05
PN-EN 60068-2-14:2024-04
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-78:2013-11
PN-EN 61000-4-29:2004
PN-EN 61000-4-2:2011
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-5:2014-10/A1:2018-01
PN-EN 61000-4-8:2010
PN-EN 61000-4-9:2016-11
PN-EN 61000-6-4:2008
PN-EN 61000-6-4:2008/A1:2012
PN-EN 61180:2016-12
PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3
PN-EN IEC 61000-4-11:2020-11
PN-EN IEC 61000-4-6:2024-03
PN-EN IEC 61000-6-2:2019-04
PN-EN IEC 61000-6-4:2019-12
PN-EN ISO 9241-305:2009
PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2
PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2
PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2
PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2