{"lab":{"_id":"69ad52a3de79e566650fb1af","accr_number":"AB 310","country":"PL","accr_body":"PCA","address":"LABORATORIUM AUTOMATYKI I TELEKOMUNIKACJI, ul. J. Chłopickiego 50, 04-275 Warszawa","categories":["electronics","environment","automotive"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":79,"name":"INSTYTUT KOLEJNICTWA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_310.pdf"],"scope_summary":"","search_text":"instytut kolejnictwa laboratorium automatyki i telekomunikacji, ul. j. chłopickiego 50, 04-275 warszawa food automotive construction pharma electronics other environment materials","status":"active","updated_at":"2026-03-08T14:51:09.067Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:09.067Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20310,podmiot.html","fields_of_testing":[{"codes":"E/6; E/53; E/54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electrical, telecommunication and electronic products and equipment"},{"codes":"F/6; F/26; F/53; F/54","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, pojazdów, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment, vehicles, telecommunication products and equipment, electronic products and equipment"},{"codes":"N/6; N/53; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of electrical, telecommunication and electronic products and equipment"},{"codes":"M/6; M/26; M/53; M/54","pl":"Badania inne wyrobów i wyposażenia elektrycznego, pojazdów, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Other tests of electrical products and equipment, vehicles, telecommunication products and equipment, electronic products and equipment"}],"issue":{"no":"24","date":"20.10.2025"},"parse_date":"2026-07-20T07:09:33.182Z","parse_source":"script-pdfplumber","map_coord":[52.231958,21.006725],"map_geo":"nominatim-city","has_en":true,"category_counts":{"electronics":38,"other":26,"environment":25,"automotive":7,"construction":2},"category_scores":{"electronics":14.73,"other":6.9,"environment":6.38,"automotive":0.5,"construction":0.04},"has_zh":true},"methods":[{"_id":"6a5dc9adf1c10c8ce825a9f1","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe: - urządzenie samoczynnego hamowania pociągu SHP","test_object_en":"Railway rail vehicles: - automatic train braking device SHP","methodology":"","methodology_en":null,"parameters":[{"name":"Funkcje związane z urządzeniem SHP podczas przejazdu pojazdu trakcyjnego nad rezonatorami torowymi"},{"name":"Rejestracje zdarzeń związanych z punktowym oddziaływaniem tor-pojazd"}],"parameters_en":[{"name":"Functions related to the SHP device during the passage of a traction vehicle over track resonators"},{"name":"Recordings of events related to spot track-vehicle interaction"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nFunkcje związane z urządzeniem SHP podczas przejazdu pojazdu trakcyjnego nad rezonatorami torowymi\nRejestracje zdarzeń związanych z punktowym oddziaływaniem tor-pojazd","reference":"PB-LA-18 wersja 6 z dnia 28.07.2017 r.","norm_bases":["PB-LA-18 wersja 6 z dnia 28.07.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe: - urządzenie samoczynnego hamowania pociągu SHP \nZakres:\nFunkcje związane z urządzeniem SHP podczas przejazdu pojazdu trakcyjnego nad rezonatorami torowymi\nRejestracje zdarzeń związanych z punktowym oddziaływaniem tor-pojazd PB-LA-18 wersja 6 z dnia 28.07.2017 r. Pojazdy szynowe kolejowe: - urzadzenie samoczynnego hamowania pociagu SHP \nZakres:\nFunkcje zwiazane z urzadzeniem SHP podczas przejazdu pojazdu trakcyjnego nad rezonatorami torowymi\nRejestracje zdarzen zwiazanych z punktowym oddzialywaniem tor-pojazd PB-LA-18 wersja 6 z dnia 28.07.2017 r.","categories":["automotive"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway rail vehicles: - automatic train braking device SHP Functions related to the SHP device during the passage of a traction vehicle over track resonators Recordings of events related to spot track-vehicle interaction PB-LA-18 wersja 6 z dnia 28.07.2017 r."},{"_id":"6a5dc9adf1c10c8ce825a9f2","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe: - urządzenie czuwaka aktywnego CA","test_object_en":"Railway rail vehicles: - active vigilance device CA","methodology":"","methodology_en":null,"parameters":[{"name":"Realizacja funkcji związanych z cyklicznym działaniem urządzenia CA w czasie jazdy pojazdu trakcyjnego"},{"name":"Rejestracje cyklicznego działania urządzenia CA"}],"parameters_en":[{"name":"Performance of functions related to the cyclic operation of the CA device while the traction vehicle is running"},{"name":"Recordings of the cyclic operation of the CA device"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nRealizacja funkcji związanych z cyklicznym działaniem urządzenia CA w czasie jazdy pojazdu trakcyjnego\nRejestracje cyklicznego działania urządzenia CA","reference":"PB-LA-19 wersja 6 z dnia 28.07.2017 r.","norm_bases":["PB-LA-19 wersja 6 z dnia 28.07.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe: - urządzenie czuwaka aktywnego CA \nZakres:\nRealizacja funkcji związanych z cyklicznym działaniem urządzenia CA w czasie jazdy pojazdu trakcyjnego\nRejestracje cyklicznego działania urządzenia CA PB-LA-19 wersja 6 z dnia 28.07.2017 r. Pojazdy szynowe kolejowe: - urzadzenie czuwaka aktywnego CA \nZakres:\nRealizacja funkcji zwiazanych z cyklicznym dzialaniem urzadzenia CA w czasie jazdy pojazdu trakcyjnego\nRejestracje cyklicznego dzialania urzadzenia CA PB-LA-19 wersja 6 z dnia 28.07.2017 r.","categories":["automotive"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway rail vehicles: - active vigilance device CA Performance of functions related to the cyclic operation of the CA device while the traction vehicle is running Recordings of the cyclic operation of the CA device PB-LA-19 wersja 6 z dnia 28.07.2017 r."},{"_id":"6a5dc9adf1c10c8ce825a9f3","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego. Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Zakres","range":"do 5 kV AC, do 6 kV DC"}],"parameters_en":[{"name":"Range","range":"do 5 kV AC, do 6 kV DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres do 5 kV AC, do 6 kV DC\nMetoda bezpośrednia","reference":"PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 61180:2016-12","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego. Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Wytrzymałość elektryczna izolacji\nZakres do 5 kV AC, do 6 kV DC\nMetoda bezpośrednia PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Urzadzenia elektryczne i elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego. Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Wytrzymalosc elektryczna izolacji\nZakres do 5 kV AC, do 6 kV DC\nMetoda bezposrednia PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["construction","electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock Dielectric strength of the insulation Direct method Range PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","parameters_zh":[{"name":"范围","range":"do 5 kV AC, do 6 kV DC"}],"search_zh":"绝缘介电强度 直接法 范围 PN-EN 61180:2016-12 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","methodology_zh":"绝缘介电强度"},{"_id":"6a5dc9adf1c10c8ce825a9f4","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego. Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock","methodology":"Rezystancja izolacji o wartości od 250 kΩ do 1100 GΩ.","methodology_en":"Insulation resistance with a value from 250 kΩ to 1100 GΩ.","parameters":[],"parameters_en":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Rezystancja izolacji o wartości od 250 kΩ do 1100 GΩ.\nMetoda bezpośrednia","reference":"PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PB-LA-12 wersja 7 z dnia 30.05.2012 r.","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego. Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Rezystancja izolacji o wartości od 250 kΩ do 1100 GΩ.\nMetoda bezpośrednia PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Urzadzenia elektryczne i elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego. Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Rezystancja izolacji o wartosci od 250 kΩ do 1100 GΩ.\nMetoda bezposrednia PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["construction","electronics"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC. Electronic products and equipment mounted on railway rolling stock Insulation resistance with a value from 250 kΩ to 1100 GΩ. Direct method PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","search_zh":"直接法 PB-LA-12 wersja 7 z dnia 30.05.2012 r. | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法"},{"_id":"6a5dc9adf1c10c8ce825a9f5","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm]","test_object_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm]","methodology":"Odporność i wytrzymałość na zimno (do - 60 oC)","methodology_en":"Immunity and resistance to cold (down to - 60 oC)","parameters":[],"parameters_en":[],"technique":"Metoda: Próba A","techniques":["Metoda: Próba A"],"technique_en":"Method: Test A","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na zimno (do - 60 oC)\nMetoda: Próba A","reference":"PN-EN 60068-2-1:2009","norm_bases":["PN-EN 60068-2-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm] Odporność i wytrzymałość na zimno (do - 60 oC)\nMetoda: Próba A PN-EN 60068-2-1:2009 Elementy i urzadzenia elektryczne, elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego oraz innych wyrobow; o wymiarach zewnetrznych nie przekraczajacych 130 (szer.) x 180 (wys.) x 180 (gleb.) [cm] Odpornosc i wytrzymalosc na zimno (do - 60 oC)\nMetoda: Proba A PN-EN 60068-2-1:2009","categories":["electronics"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Immunity and resistance to cold (down to - 60 oC) Method: Test A PN-EN 60068-2-1:2009","search_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm] PN-EN 60068-2-1:2009","test_object_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm]"},{"_id":"6a5dc9adf1c10c8ce825a9f6","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność i wytrzymałość na zimno (do - 60 oC)","methodology_en":"Immunity and resistance to cold (down to - 60 oC)","parameters":[],"parameters_en":[],"technique":"Metoda: Próba A","techniques":["Metoda: Próba A"],"technique_en":"Method: Test A","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na zimno (do - 60 oC)\nMetoda: Próba A","reference":"PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","norm_bases":["PN-EN 50155:2018-01","PN-EN 50155:2022-05","PN-EN 50125-1:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność i wytrzymałość na zimno (do - 60 oC)\nMetoda: Próba A PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc i wytrzymalosc na zimno (do - 60 oC)\nMetoda: Proba A PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","categories":["electronics"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity and resistance to cold (down to - 60 oC) Method: Test A PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","search_zh":"安装于铁道车辆上的电子产品与装备 PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","test_object_zh":"安装于铁道车辆上的电子产品与装备"},{"_id":"6a5dc9adf1c10c8ce825a9f7","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyposażenie dla sygnalizacji i telekomunikacji","test_object_en":"Signalling and telecommunications equipment","methodology":"Odporność i wytrzymałość na zimno (do - 60 oC)","methodology_en":"Immunity and resistance to cold (down to - 60 oC)","parameters":[],"parameters_en":[],"technique":"Metoda: Próba A","techniques":["Metoda: Próba A"],"technique_en":"Method: Test A","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na zimno (do - 60 oC)\nMetoda: Próba A","reference":"PN-EN 50125-3:2003","norm_bases":["PN-EN 50125-3:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie dla sygnalizacji i telekomunikacji Odporność i wytrzymałość na zimno (do - 60 oC)\nMetoda: Próba A PN-EN 50125-3:2003 Wyposazenie dla sygnalizacji i telekomunikacji Odpornosc i wytrzymalosc na zimno (do - 60 oC)\nMetoda: Proba A PN-EN 50125-3:2003","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Signalling and telecommunications equipment Immunity and resistance to cold (down to - 60 oC) Method: Test A PN-EN 50125-3:2003","search_zh":"信号与电信配套设备 PN-EN 50125-3:2003","test_object_zh":"信号与电信配套设备"},{"_id":"6a5dc9adf1c10c8ce825a9f8","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm]","test_object_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm]","methodology":"Odporność i wytrzymałość na suche gorąco (do + 150 oC)","methodology_en":"Immunity and resistance to dry heat (up to + 150 oC)","parameters":[],"parameters_en":[],"technique":"Metoda: Próba B","techniques":["Metoda: Próba B"],"technique_en":"Method: Test B","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na suche gorąco (do + 150 oC)\nMetoda: Próba B","reference":"PN-EN 60068-2-2:2009","norm_bases":["PN-EN 60068-2-2:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm] Odporność i wytrzymałość na suche gorąco (do + 150 oC)\nMetoda: Próba B PN-EN 60068-2-2:2009 Elementy i urzadzenia elektryczne, elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego oraz innych wyrobow; o wymiarach zewnetrznych nie przekraczajacych 130 (szer.) x 180 (wys.) x 180 (gleb.) [cm] Odpornosc i wytrzymalosc na suche goraco (do + 150 oC)\nMetoda: Proba B PN-EN 60068-2-2:2009","categories":["electronics"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Immunity and resistance to dry heat (up to + 150 oC) Method: Test B PN-EN 60068-2-2:2009","search_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm] PN-EN 60068-2-2:2009","test_object_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm]"},{"_id":"6a5dc9adf1c10c8ce825a9f9","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność i wytrzymałość na suche gorąco (do + 150 oC)","methodology_en":"Immunity and resistance to dry heat (up to + 150 oC)","parameters":[],"parameters_en":[],"technique":"Metoda: Próba B","techniques":["Metoda: Próba B"],"technique_en":"Method: Test B","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na suche gorąco (do + 150 oC)\nMetoda: Próba B","reference":"PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","norm_bases":["PN-EN 50155:2018-01","PN-EN 50155:2022-05","PN-EN 50125-1:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność i wytrzymałość na suche gorąco (do + 150 oC)\nMetoda: Próba B PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc i wytrzymalosc na suche goraco (do + 150 oC)\nMetoda: Proba B PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","categories":["electronics"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity and resistance to dry heat (up to + 150 oC) Method: Test B PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","search_zh":"安装于铁道车辆上的电子产品与装备 PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","test_object_zh":"安装于铁道车辆上的电子产品与装备"},{"_id":"6a5dc9adf1c10c8ce825a9fa","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyposażenie dla sygnalizacji i telekomunikacji","test_object_en":"Signalling and telecommunications equipment","methodology":"Odporność i wytrzymałość na suche gorąco (do + 150 oC)","methodology_en":"Immunity and resistance to dry heat (up to + 150 oC)","parameters":[],"parameters_en":[],"technique":"Metoda: Próba B","techniques":["Metoda: Próba B"],"technique_en":"Method: Test B","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na suche gorąco (do + 150 oC)\nMetoda: Próba B","reference":"PN-EN 50125-3:2003","norm_bases":["PN-EN 50125-3:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie dla sygnalizacji i telekomunikacji Odporność i wytrzymałość na suche gorąco (do + 150 oC)\nMetoda: Próba B PN-EN 50125-3:2003 Wyposazenie dla sygnalizacji i telekomunikacji Odpornosc i wytrzymalosc na suche goraco (do + 150 oC)\nMetoda: Proba B PN-EN 50125-3:2003","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Signalling and telecommunications equipment Immunity and resistance to dry heat (up to + 150 oC) Method: Test B PN-EN 50125-3:2003","search_zh":"信号与电信配套设备 PN-EN 50125-3:2003","test_object_zh":"信号与电信配套设备"},{"_id":"6a5dc9adf1c10c8ce825a9fb","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm]","test_object_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm]","methodology":"Odporność i wytrzymałość na wilgotne gorąco stałe","methodology_en":"Resistance and endurance to steady damp heat","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Cab","techniques":["Metoda: Próba Cab"],"technique_en":"Method: Test Cab","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco stałe\nMetoda: Próba Cab","reference":"PN-EN 60068-2-78:2013-11","norm_bases":["PN-EN 60068-2-78:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm] Odporność i wytrzymałość na wilgotne gorąco stałe\nMetoda: Próba Cab PN-EN 60068-2-78:2013-11 Elementy i urzadzenia elektryczne, elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego oraz innych wyrobow; o wymiarach zewnetrznych nie przekraczajacych 130 (szer.) x 180 (wys.) x 180 (gleb.) [cm] Odpornosc i wytrzymalosc na wilgotne goraco stale\nMetoda: Proba Cab PN-EN 60068-2-78:2013-11","categories":["electronics"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Resistance and endurance to steady damp heat Method: Test Cab PN-EN 60068-2-78:2013-11","search_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm] PN-EN 60068-2-78:2013-11","test_object_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm]"},{"_id":"6a5dc9adf1c10c8ce825a9fc","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyposażenie dla sygnalizacji i telekomunikacji","test_object_en":"Signalling and telecommunications equipment","methodology":"Odporność i wytrzymałość na wilgotne gorąco stałe","methodology_en":"Resistance and endurance to steady damp heat","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Cab","techniques":["Metoda: Próba Cab"],"technique_en":"Method: Test Cab","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco stałe\nMetoda: Próba Cab","reference":"PN-EN 50125-3:2003","norm_bases":["PN-EN 50125-3:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie dla sygnalizacji i telekomunikacji Odporność i wytrzymałość na wilgotne gorąco stałe\nMetoda: Próba Cab PN-EN 50125-3:2003 Wyposazenie dla sygnalizacji i telekomunikacji Odpornosc i wytrzymalosc na wilgotne goraco stale\nMetoda: Proba Cab PN-EN 50125-3:2003","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Signalling and telecommunications equipment Resistance and endurance to steady damp heat Method: Test Cab PN-EN 50125-3:2003","search_zh":"信号与电信配套设备 PN-EN 50125-3:2003","test_object_zh":"信号与电信配套设备"},{"_id":"6a5dc9adf1c10c8ce825a9fd","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm]","test_object_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm]","methodology":"Odporność i wytrzymałość na wilgotne gorąco cykliczne","methodology_en":"Immunity and resistance to cyclic damp heat","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Db","techniques":["Metoda: Próba Db"],"technique_en":"Method: Test Db","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco cykliczne\nMetoda: Próba Db","reference":"PN-EN 60068-2-30:2008","norm_bases":["PN-EN 60068-2-30:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm] Odporność i wytrzymałość na wilgotne gorąco cykliczne\nMetoda: Próba Db PN-EN 60068-2-30:2008 Elementy i urzadzenia elektryczne, elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego oraz innych wyrobow; o wymiarach zewnetrznych nie przekraczajacych 130 (szer.) x 180 (wys.) x 180 (gleb.) [cm] Odpornosc i wytrzymalosc na wilgotne goraco cykliczne\nMetoda: Proba Db PN-EN 60068-2-30:2008","categories":["electronics"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Immunity and resistance to cyclic damp heat Method: Test Db PN-EN 60068-2-30:2008","search_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm] PN-EN 60068-2-30:2008","test_object_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm]"},{"_id":"6a5dc9adf1c10c8ce825a9fe","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność i wytrzymałość na wilgotne gorąco cykliczne","methodology_en":"Immunity and resistance to cyclic damp heat","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Db","techniques":["Metoda: Próba Db"],"technique_en":"Method: Test Db","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco cykliczne\nMetoda: Próba Db","reference":"PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","norm_bases":["PN-EN 50155:2018-01","PN-EN 50155:2022-05","PN-EN 50125-1:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność i wytrzymałość na wilgotne gorąco cykliczne\nMetoda: Próba Db PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc i wytrzymalosc na wilgotne goraco cykliczne\nMetoda: Proba Db PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","categories":["electronics"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity and resistance to cyclic damp heat Method: Test Db PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","search_zh":"安装于铁道车辆上的电子产品与装备 PN-EN 50155:2018-01 | PN-EN 50155:2022-05 | PN-EN 50125-1:2014-06","test_object_zh":"安装于铁道车辆上的电子产品与装备"},{"_id":"6a5dc9adf1c10c8ce825a9ff","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyposażenie dla sygnalizacji i telekomunikacji","test_object_en":"Signalling and telecommunications equipment","methodology":"Odporność i wytrzymałość na wilgotne gorąco cykliczne","methodology_en":"Immunity and resistance to cyclic damp heat","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Db","techniques":["Metoda: Próba Db"],"technique_en":"Method: Test Db","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco cykliczne\nMetoda: Próba Db","reference":"PN-EN 50125-3:2003","norm_bases":["PN-EN 50125-3:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie dla sygnalizacji i telekomunikacji Odporność i wytrzymałość na wilgotne gorąco cykliczne\nMetoda: Próba Db PN-EN 50125-3:2003 Wyposazenie dla sygnalizacji i telekomunikacji Odpornosc i wytrzymalosc na wilgotne goraco cykliczne\nMetoda: Proba Db PN-EN 50125-3:2003","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Signalling and telecommunications equipment Immunity and resistance to cyclic damp heat Method: Test Db PN-EN 50125-3:2003","search_zh":"信号与电信配套设备 PN-EN 50125-3:2003","test_object_zh":"信号与电信配套设备"},{"_id":"6a5dc9adf1c10c8ce825aa00","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm]","test_object_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm]","methodology":"Odporność i wytrzymałość wyrobów na zmiany temperatury","methodology_en":"Resistance and endurance of products to change of temperature","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Nb","techniques":["Metoda: Próba Nb"],"technique_en":"Method: Test Nb","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość wyrobów na zmiany temperatury\nMetoda: Próba Nb","reference":"PN-EN 60068-2-14:2024-04","norm_bases":["PN-EN 60068-2-14:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy i urządzenia elektryczne, elektroniczne niskiego napięcia o napięciu znamionowym nie wyższym niż 1 kV prądu przemiennego lub 1,5 kV prądu stałego oraz innych wyrobów; o wymiarach zewnętrznych nie przekraczających 130 (szer.) x 180 (wys.) x 180 (głęb.) [cm] Odporność i wytrzymałość wyrobów na zmiany temperatury\nMetoda: Próba Nb PN-EN 60068-2-14:2024-04 Elementy i urzadzenia elektryczne, elektroniczne niskiego napiecia o napieciu znamionowym nie wyzszym niz 1 kV pradu przemiennego lub 1,5 kV pradu stalego oraz innych wyrobow; o wymiarach zewnetrznych nie przekraczajacych 130 (szer.) x 180 (wys.) x 180 (gleb.) [cm] Odpornosc i wytrzymalosc wyrobow na zmiany temperatury\nMetoda: Proba Nb PN-EN 60068-2-14:2024-04","categories":["electronics"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage electrical and electronic components and equipment with a rated voltage not exceeding 1 kV AC or 1,5 kV DC and other products; with external dimensions not exceeding 130 (width) x 180 (height) x 180 (depth) [cm] Resistance and endurance of products to change of temperature Method: Test Nb PN-EN 60068-2-14:2024-04","search_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm] PN-EN 60068-2-14:2024-04","test_object_zh":"额定电压不高于交流 1 kV 或直流 1,5 kV 的低压电气与电子元件及设备以及其他制品；外形尺寸不超过 130（宽）x 180（高）x 180（深）[cm]"},{"_id":"6a5dc9adf1c10c8ce825aa01","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyposażenie dla sygnalizacji i telekomunikacji","test_object_en":"Signalling and telecommunications equipment","methodology":"Odporność i wytrzymałość wyrobów na zmiany temperatury","methodology_en":"Resistance and endurance of products to change of temperature","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Nb","techniques":["Metoda: Próba Nb"],"technique_en":"Method: Test Nb","computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość wyrobów na zmiany temperatury\nMetoda: Próba Nb","reference":"PN-EN 50125-3:2003","norm_bases":["PN-EN 50125-3:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie dla sygnalizacji i telekomunikacji Odporność i wytrzymałość wyrobów na zmiany temperatury\nMetoda: Próba Nb PN-EN 50125-3:2003 Wyposazenie dla sygnalizacji i telekomunikacji Odpornosc i wytrzymalosc wyrobow na zmiany temperatury\nMetoda: Proba Nb PN-EN 50125-3:2003","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Signalling and telecommunications equipment Resistance and endurance of products to change of temperature Method: Test Nb PN-EN 50125-3:2003","search_zh":"信号与电信配套设备 PN-EN 50125-3:2003","test_object_zh":"信号与电信配套设备"},{"_id":"6a5dc9adf1c10c8ce825aa02","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi","methodology_en":"Resistance to simulated solar radiation occurring at the earth's surface","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Sa","techniques":["Metoda: Próba Sa"],"technique_en":"Method: Test Sa","computed":[],"computed_en":[],"activity":"Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi\nMetoda: Próba Sa","reference":"PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","norm_bases":["PN-EN 50125-1:2014-06 wg pkt 4.9","PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi\nMetoda: Próba Sa PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na odwzorowane promieniowanie sloneczne wystepujace na powierzchni ziemi\nMetoda: Proba Sa PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","categories":["electronics"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Resistance to simulated solar radiation occurring at the earth's surface Method: Test Sa PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","search_zh":"安装于铁道车辆上的电子产品与装备 PN-EN 50125-1:2014-06 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","test_object_zh":"安装于铁道车辆上的电子产品与装备"},{"_id":"6a5dc9adf1c10c8ce825aa03","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elektryczne urządzenia stacjonarne","test_object_en":"Stationary electrical equipment","methodology":"Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi","methodology_en":"Resistance to simulated solar radiation occurring at the earth's surface","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Sa","techniques":["Metoda: Próba Sa"],"technique_en":"Method: Test Sa","computed":[],"computed_en":[],"activity":"Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi\nMetoda: Próba Sa","reference":"PN-EN 50125-2:2003 wg pkt 4.8 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","norm_bases":["PN-EN 50125-2:2003 wg pkt 4.8","PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne urządzenia stacjonarne Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi\nMetoda: Próba Sa PN-EN 50125-2:2003 wg pkt 4.8 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3 Elektryczne urzadzenia stacjonarne Odpornosc na odwzorowane promieniowanie sloneczne wystepujace na powierzchni ziemi\nMetoda: Proba Sa PN-EN 50125-2:2003 wg pkt 4.8 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary electrical equipment Resistance to simulated solar radiation occurring at the earth's surface Method: Test Sa PN-EN 50125-2:2003 wg pkt 4.8 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3"},{"_id":"6a5dc9adf1c10c8ce825aa04","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyposażenie dla sygnalizacji i telekomunikacji","test_object_en":"Signalling and telecommunications equipment","methodology":"Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi","methodology_en":"Resistance to simulated solar radiation occurring at the earth's surface","parameters":[],"parameters_en":[],"technique":"Metoda: Próba Sa","techniques":["Metoda: Próba Sa"],"technique_en":"Method: Test Sa","computed":[],"computed_en":[],"activity":"Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi\nMetoda: Próba Sa","reference":"PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","norm_bases":["PN-EN 50125-3:2003 wg pkt 4.9","PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie dla sygnalizacji i telekomunikacji Odporność na odwzorowane promieniowanie słoneczne występujące na powierzchni ziemi\nMetoda: Próba Sa PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3 Wyposazenie dla sygnalizacji i telekomunikacji Odpornosc na odwzorowane promieniowanie sloneczne wystepujace na powierzchni ziemi\nMetoda: Proba Sa PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Signalling and telecommunications equipment Resistance to simulated solar radiation occurring at the earth's surface Method: Test Sa PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","search_zh":"信号与电信配套设备 PN-EN 50125-3:2003 wg pkt 4.9 | PN-EN IEC 60068-2-5:2018-08 wg pkt 5.3","test_object_zh":"信号与电信配套设备"},{"_id":"6a5dc9adf1c10c8ce825aa05","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"wyładowania","range":"(0,5 – 30) kV"}],"parameters_en":[{"name":"discharges","range":"(0,5 – 30) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia","reference":"PN-EN 61000-4-2:2011","norm_bases":["PN-EN 61000-4-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia PN-EN 61000-4-2:2011 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na wyladowania elektrostatyczne\nwyladowania (0,5 – 30) kV\nMetoda bezposrednia PN-EN 61000-4-2:2011","categories":["electronics"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to electrostatic discharge Direct method discharges PN-EN 61000-4-2:2011","search_zh":"电气、电信与电子产品及设备 静电放电抗扰度 直接法 放电 PN-EN 61000-4-2:2011","technique_zh":"直接法","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"静电放电抗扰度","parameters_zh":[{"name":"放电","range":"(0,5 – 30) kV"}]},{"_id":"6a5dc9adf1c10c8ce825aa06","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"wyładowania","range":"(0,5 – 30) kV"}],"parameters_en":[{"name":"discharges","range":"(0,5 – 30) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na wyladowania elektrostatyczne\nwyladowania (0,5 – 30) kV\nMetoda bezposrednia PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to electrostatic discharge Direct method discharges PN-EN IEC 61000-6-2:2019-04","search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 静电放电抗扰度 直接法 放电 PN-EN IEC 61000-6-2:2019-04","technique_zh":"直接法","methodology_zh":"静电放电抗扰度","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备","parameters_zh":[{"name":"放电","range":"(0,5 – 30) kV"}]},{"_id":"6a5dc9adf1c10c8ce825aa07","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"wyładowania","range":"(0,5 – 30) kV"}],"parameters_en":[{"name":"discharges","range":"(0,5 – 30) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na wyladowania elektrostatyczne\nwyladowania (0,5 – 30) kV\nMetoda bezposrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["electronics"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity to electrostatic discharge Direct method discharges PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","search_zh":"安装于铁道车辆上的电子产品与装备 静电放电抗扰度 直接法 放电 PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","methodology_zh":"静电放电抗扰度","test_object_zh":"安装于铁道车辆上的电子产品与装备","parameters_zh":[{"name":"放电","range":"(0,5 – 30) kV"}]},{"_id":"6a5dc9adf1c10c8ce825aa08","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"wyładowania","range":"(0,5 – 30) kV"}],"parameters_en":[{"name":"discharges","range":"(0,5 – 30) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Odpornosc na wyladowania elektrostatyczne\nwyladowania (0,5 – 30) kV\nMetoda bezposrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Immunity to electrostatic discharge Direct method discharges PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","search_zh":"铁路行车控制与通信设备 静电放电抗扰度 直接法 放电 PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","technique_zh":"直接法","methodology_zh":"静电放电抗扰度","test_object_zh":"铁路行车控制与通信设备","parameters_zh":[{"name":"放电","range":"(0,5 – 30) kV"}]},{"_id":"6a5dc9adf1c10c8ce825aa09","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią.","test_object_en":"Stationary equipment of the power supply system.","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"wyładowania","range":"(0,5 – 30) kV"}],"parameters_en":[{"name":"discharges","range":"(0,5 – 30) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią. Odporność na wyładowania elektrostatyczne\nwyładowania (0,5 – 30) kV\nMetoda bezpośrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia. Odpornosc na wyladowania elektrostatyczne\nwyladowania (0,5 – 30) kV\nMetoda bezposrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system. Immunity to electrostatic discharge Direct method discharges PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","search_zh":"静电放电抗扰度 直接法 放电 PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","technique_zh":"直接法","methodology_zh":"静电放电抗扰度","parameters_zh":[{"name":"放电","range":"(0,5 – 30) kV"}]},{"_id":"6a5dc9adf1c10c8ce825aa0a","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","reference":"PN-EN 61000-4-3:2021-06","norm_bases":["PN-EN 61000-4-3:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej PN-EN 61000-4-3:2021-06 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej PN-EN 61000-4-3:2021-06","categories":["electronics"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to radiated radio-frequency electromagnetic field PN-EN 61000-4-3:2021-06","search_zh":"电气、电信与电子产品及设备 射频辐射电磁场抗扰度 PN-EN 61000-4-3:2021-06","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"射频辐射电磁场抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa0b","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to radiated radio-frequency electromagnetic field PN-EN IEC 61000-6-2:2019-04","methodology_zh":"射频辐射电磁场抗扰度","search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 射频辐射电磁场抗扰度 PN-EN IEC 61000-6-2:2019-04","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备"},{"_id":"6a5dc9adf1c10c8ce825aa0c","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["electronics"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity to radiated radio-frequency electromagnetic field PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","methodology_zh":"射频辐射电磁场抗扰度","search_zh":"安装于铁道车辆上的电子产品与装备 射频辐射电磁场抗扰度 PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","test_object_zh":"安装于铁道车辆上的电子产品与装备"},{"_id":"6a5dc9adf1c10c8ce825aa0d","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Immunity to radiated radio-frequency electromagnetic field PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","methodology_zh":"射频辐射电磁场抗扰度","search_zh":"铁路行车控制与通信设备 射频辐射电磁场抗扰度 PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","test_object_zh":"铁路行车控制与通信设备"},{"_id":"6a5dc9adf1c10c8ce825aa0e","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią.","test_object_en":"Stationary equipment of the power supply system.","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią. Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia. Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system. Immunity to radiated radio-frequency electromagnetic field PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","methodology_zh":"射频辐射电磁场抗扰度","search_zh":"射频辐射电磁场抗扰度 PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07"},{"_id":"6a5dc9adf1c10c8ce825aa0f","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns","methodology_en":"Immunity to electrical fast transient bursts 5/50 ns","parameters":[{"name":"Zakres","range":"(0,2 – 4,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 4,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia","reference":"PN-EN 61000-4-4:2013-05","norm_bases":["PN-EN 61000-4-4:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia PN-EN 61000-4-4:2013-05 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na serie szybkich elektrycznych stanow przejsciowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezposrednia PN-EN 61000-4-4:2013-05","categories":["electronics"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to electrical fast transient bursts 5/50 ns Direct method Range PN-EN 61000-4-4:2013-05","parameters_zh":[{"name":"范围","range":"(0,2 – 4,5) kV"}],"search_zh":"电气、电信与电子产品及设备 5/50 ns 电快速瞬变脉冲群抗扰度 直接法 范围 PN-EN 61000-4-4:2013-05","technique_zh":"直接法","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"5/50 ns 电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa10","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns","methodology_en":"Immunity to electrical fast transient bursts 5/50 ns","parameters":[{"name":"Zakres","range":"(0,2 – 4,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 4,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na serie szybkich elektrycznych stanow przejsciowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezposrednia PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to electrical fast transient bursts 5/50 ns Direct method Range PN-EN IEC 61000-6-2:2019-04","parameters_zh":[{"name":"范围","range":"(0,2 – 4,5) kV"}],"search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 5/50 ns 电快速瞬变脉冲群抗扰度 直接法 范围 PN-EN IEC 61000-6-2:2019-04","technique_zh":"直接法","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备","methodology_zh":"5/50 ns 电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa11","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns","methodology_en":"Immunity to electrical fast transient bursts 5/50 ns","parameters":[{"name":"Zakres","range":"(0,2 – 4,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 4,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na serie szybkich elektrycznych stanow przejsciowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezposrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["electronics"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity to electrical fast transient bursts 5/50 ns Direct method Range PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","parameters_zh":[{"name":"范围","range":"(0,2 – 4,5) kV"}],"search_zh":"安装于铁道车辆上的电子产品与装备 5/50 ns 电快速瞬变脉冲群抗扰度 直接法 范围 PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","test_object_zh":"安装于铁道车辆上的电子产品与装备","methodology_zh":"5/50 ns 电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa12","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns","methodology_en":"Immunity to electrical fast transient bursts 5/50 ns","parameters":[{"name":"Zakres","range":"(0,2 – 4,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 4,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Odpornosc na serie szybkich elektrycznych stanow przejsciowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezposrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Immunity to electrical fast transient bursts 5/50 ns Direct method Range PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","parameters_zh":[{"name":"范围","range":"(0,2 – 4,5) kV"}],"search_zh":"铁路行车控制与通信设备 5/50 ns 电快速瞬变脉冲群抗扰度 直接法 范围 PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","technique_zh":"直接法","test_object_zh":"铁路行车控制与通信设备","methodology_zh":"5/50 ns 电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa13","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią","test_object_en":"Stationary equipment of the power supply system","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns","methodology_en":"Immunity to electrical fast transient bursts 5/50 ns","parameters":[{"name":"Zakres","range":"(0,2 – 4,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 4,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią Odporność na serie szybkich elektrycznych stanów przejściowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezpośrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia Odpornosc na serie szybkich elektrycznych stanow przejsciowych 5/50 ns\nZakres (0,2 – 4,5) kV\nMetoda bezposrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system Immunity to electrical fast transient bursts 5/50 ns Direct method Range PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","parameters_zh":[{"name":"范围","range":"(0,2 – 4,5) kV"}],"search_zh":"供电系统固定设备 5/50 ns 电快速瞬变脉冲群抗扰度 直接法 范围 PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","technique_zh":"直接法","test_object_zh":"供电系统固定设备","methodology_zh":"5/50 ns 电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa14","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na udary elektryczne (1,2/50 – 8/20) μs","methodology_en":"Immunity to electrical surges (1,2/50 – 8/20) μs","parameters":[{"name":"Zakres","range":"(0,2 – 5,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 5,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia","reference":"PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01","norm_bases":["PN-EN 61000-4-5:2014-10","PN-EN 61000-4-5:2014-10/A1:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezposrednia PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01","categories":["electronics"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to electrical surges (1,2/50 – 8/20) μs Direct method Range PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01","parameters_zh":[{"name":"范围","range":"(0,2 – 5,5) kV"}],"search_zh":"电气、电信与电子产品及设备 (1,2/50 – 8/20) μs 浪涌抗扰度 直接法 范围 PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01","technique_zh":"直接法","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"(1,2/50 – 8/20) μs 浪涌抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa15","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na udary elektryczne (1,2/50 – 8/20) μs","methodology_en":"Immunity to electrical surges (1,2/50 – 8/20) μs","parameters":[{"name":"Zakres","range":"(0,2 – 5,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 5,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezposrednia PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to electrical surges (1,2/50 – 8/20) μs Direct method Range PN-EN IEC 61000-6-2:2019-04","parameters_zh":[{"name":"范围","range":"(0,2 – 5,5) kV"}],"search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 (1,2/50 – 8/20) μs 浪涌抗扰度 直接法 范围 PN-EN IEC 61000-6-2:2019-04","technique_zh":"直接法","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备","methodology_zh":"(1,2/50 – 8/20) μs 浪涌抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa16","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na udary elektryczne (1,2/50 – 8/20) μs","methodology_en":"Immunity to electrical surges (1,2/50 – 8/20) μs","parameters":[{"name":"Zakres","range":"(0,2 – 5,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 5,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezposrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["electronics"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity to electrical surges (1,2/50 – 8/20) μs Direct method Range PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","parameters_zh":[{"name":"范围","range":"(0,2 – 5,5) kV"}],"search_zh":"安装于铁道车辆上的电子产品与装备 (1,2/50 – 8/20) μs 浪涌抗扰度 直接法 范围 PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","test_object_zh":"安装于铁道车辆上的电子产品与装备","methodology_zh":"(1,2/50 – 8/20) μs 浪涌抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa17","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Odporność na udary elektryczne (1,2/50 – 8/20) μs","methodology_en":"Immunity to electrical surges (1,2/50 – 8/20) μs","parameters":[{"name":"Zakres","range":"(0,2 – 5,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 5,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Odpornosc na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezposrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Immunity to electrical surges (1,2/50 – 8/20) μs Direct method Range PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","parameters_zh":[{"name":"范围","range":"(0,2 – 5,5) kV"}],"search_zh":"铁路行车控制与通信设备 (1,2/50 – 8/20) μs 浪涌抗扰度 直接法 范围 PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","technique_zh":"直接法","test_object_zh":"铁路行车控制与通信设备","methodology_zh":"(1,2/50 – 8/20) μs 浪涌抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa18","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią","test_object_en":"Stationary equipment of the power supply system","methodology":"Odporność na udary elektryczne (1,2/50 – 8/20) μs","methodology_en":"Immunity to electrical surges (1,2/50 – 8/20) μs","parameters":[{"name":"Zakres","range":"(0,2 – 5,5) kV"}],"parameters_en":[{"name":"Range","range":"(0,2 – 5,5) kV"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią Odporność na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezpośrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia Odpornosc na udary elektryczne (1,2/50 – 8/20) μs\nZakres (0,2 – 5,5) kV\nMetoda bezposrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system Immunity to electrical surges (1,2/50 – 8/20) μs Direct method Range PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","parameters_zh":[{"name":"范围","range":"(0,2 – 5,5) kV"}],"search_zh":"供电系统固定设备 (1,2/50 – 8/20) μs 浪涌抗扰度 直接法 范围 PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","technique_zh":"直接法","test_object_zh":"供电系统固定设备","methodology_zh":"(1,2/50 – 8/20) μs 浪涌抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa19","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Zakres częstotliwości","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Poziom","range":"do 30 V (r.m.s.)"}],"parameters_en":[{"name":"Frequency range","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Level","range":"do 30 V (r.m.s.)"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-4-6:2024-03","norm_bases":["PN-EN IEC 61000-4-6:2024-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia PN-EN IEC 61000-4-6:2024-03 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na zaburzenia przewodzone, indukowane przez pole o czestotliwosciach radiowych\nZakres:\nZakres czestotliwosci 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezposrednia PN-EN IEC 61000-4-6:2024-03","categories":["electronics"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to conducted disturbances induced by radio-frequency fields Direct method Frequency range MHz Level PN-EN IEC 61000-4-6:2024-03","search_zh":"电气、电信与电子产品及设备 射频场感应的传导骚扰抗扰度 直接法 频率范围 MHz 电平 PN-EN IEC 61000-4-6:2024-03","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"150 kHz – 230"},{"name":"MHz"},{"name":"电平","range":"do 30 V (r.m.s.)"}],"test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa1a","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Zakres częstotliwości","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Poziom","range":"do 30 V (r.m.s.)"}],"parameters_en":[{"name":"Frequency range","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Level","range":"do 30 V (r.m.s.)"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na zaburzenia przewodzone, indukowane przez pole o czestotliwosciach radiowych\nZakres:\nZakres czestotliwosci 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezposrednia PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to conducted disturbances induced by radio-frequency fields Direct method Frequency range MHz Level PN-EN IEC 61000-6-2:2019-04","search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 射频场感应的传导骚扰抗扰度 直接法 频率范围 MHz 电平 PN-EN IEC 61000-6-2:2019-04","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"150 kHz – 230"},{"name":"MHz"},{"name":"电平","range":"do 30 V (r.m.s.)"}],"test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa1b","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Zakres częstotliwości","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Poziom","range":"do 30 V (r.m.s.)"}],"parameters_en":[{"name":"Frequency range","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Level","range":"do 30 V (r.m.s.)"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na zaburzenia przewodzone, indukowane przez pole o czestotliwosciach radiowych\nZakres:\nZakres czestotliwosci 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezposrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["electronics"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity to conducted disturbances induced by radio-frequency fields Direct method Frequency range MHz Level PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","search_zh":"安装于铁道车辆上的电子产品与装备 射频场感应的传导骚扰抗扰度 直接法 频率范围 MHz 电平 PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"150 kHz – 230"},{"name":"MHz"},{"name":"电平","range":"do 30 V (r.m.s.)"}],"test_object_zh":"安装于铁道车辆上的电子产品与装备","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa1c","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Zakres częstotliwości","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Poziom","range":"do 30 V (r.m.s.)"}],"parameters_en":[{"name":"Frequency range","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Level","range":"do 30 V (r.m.s.)"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Odpornosc na zaburzenia przewodzone, indukowane przez pole o czestotliwosciach radiowych\nZakres:\nZakres czestotliwosci 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezposrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Immunity to conducted disturbances induced by radio-frequency fields Direct method Frequency range MHz Level PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","search_zh":"铁路行车控制与通信设备 射频场感应的传导骚扰抗扰度 直接法 频率范围 MHz 电平 PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"150 kHz – 230"},{"name":"MHz"},{"name":"电平","range":"do 30 V (r.m.s.)"}],"test_object_zh":"铁路行车控制与通信设备","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa1d","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią","test_object_en":"Stationary equipment of the power supply system","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Zakres częstotliwości","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Poziom","range":"do 30 V (r.m.s.)"}],"parameters_en":[{"name":"Frequency range","range":"150 kHz – 230"},{"name":"MHz"},{"name":"Level","range":"do 30 V (r.m.s.)"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią Odporność na zaburzenia przewodzone, indukowane przez pole o częstotliwościach radiowych\nZakres:\nZakres częstotliwości 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezpośrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia Odpornosc na zaburzenia przewodzone, indukowane przez pole o czestotliwosciach radiowych\nZakres:\nZakres czestotliwosci 150 kHz – 230\nMHz\nPoziom do 30 V (r.m.s.)\nMetoda bezposrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system Immunity to conducted disturbances induced by radio-frequency fields Direct method Frequency range MHz Level PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","search_zh":"供电系统固定设备 射频场感应的传导骚扰抗扰度 直接法 频率范围 MHz 电平 PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"150 kHz – 230"},{"name":"MHz"},{"name":"电平","range":"do 30 V (r.m.s.)"}],"test_object_zh":"供电系统固定设备","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa1e","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[{"name":"Zakres","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"parameters_en":[{"name":"Range","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia","reference":"PN-EN 61000-4-8:2010","norm_bases":["PN-EN 61000-4-8:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia PN-EN 61000-4-8:2010 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezposrednia PN-EN 61000-4-8:2010","categories":["electronics"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to power-frequency magnetic field Direct method Range 1000 A/m (r.m.s.) - system a.c. PN-EN 61000-4-8:2010","parameters_zh":[{"name":"范围","range":"50 Hz, 0 Hz"},{"name":"1000 A/m（有效值）－ 交流系统"}],"search_zh":"电气、电信与电子产品及设备 工频磁场抗扰度 直接法 范围 1000 A/m（有效值）－ 交流系统 PN-EN 61000-4-8:2010","technique_zh":"直接法","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"工频磁场抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa1f","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[{"name":"Zakres","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"parameters_en":[{"name":"Range","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezposrednia PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to power-frequency magnetic field Direct method Range 1000 A/m (r.m.s.) - system a.c. PN-EN IEC 61000-6-2:2019-04","parameters_zh":[{"name":"范围","range":"50 Hz, 0 Hz"},{"name":"1000 A/m（有效值）－ 交流系统"}],"search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 工频磁场抗扰度 直接法 范围 1000 A/m（有效值）－ 交流系统 PN-EN IEC 61000-6-2:2019-04","technique_zh":"直接法","methodology_zh":"工频磁场抗扰度","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备"},{"_id":"6a5dc9adf1c10c8ce825aa20","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[{"name":"Zakres","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"parameters_en":[{"name":"Range","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezposrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Immunity to power-frequency magnetic field Direct method Range 1000 A/m (r.m.s.) - system a.c. PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","parameters_zh":[{"name":"范围","range":"50 Hz, 0 Hz"},{"name":"1000 A/m（有效值）－ 交流系统"}],"search_zh":"铁路行车控制与通信设备 工频磁场抗扰度 直接法 范围 1000 A/m（有效值）－ 交流系统 PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","technique_zh":"直接法","methodology_zh":"工频磁场抗扰度","test_object_zh":"铁路行车控制与通信设备"},{"_id":"6a5dc9adf1c10c8ce825aa21","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią","test_object_en":"Stationary equipment of the power supply system","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[{"name":"Zakres","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"parameters_en":[{"name":"Range","range":"50 Hz, 0 Hz"},{"name":"1000 A/m (r.m.s.) - system a.c."}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezpośrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nZakres:\nZakres 50 Hz, 0 Hz\n1000 A/m (r.m.s.) - system a.c.\nMetoda bezposrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system Immunity to power-frequency magnetic field Direct method Range 1000 A/m (r.m.s.) - system a.c. PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","parameters_zh":[{"name":"范围","range":"50 Hz, 0 Hz"},{"name":"1000 A/m（有效值）－ 交流系统"}],"search_zh":"供电系统固定设备 工频磁场抗扰度 直接法 范围 1000 A/m（有效值）－ 交流系统 PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","technique_zh":"直接法","methodology_zh":"工频磁场抗扰度","test_object_zh":"供电系统固定设备"},{"_id":"6a5dc9adf1c10c8ce825aa22","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Instalacje przemysłowe i kolejowe, elektrownie, podstacje średniego i wysokiego napięcia","test_object_en":"Industrial and railway installations, power plants, medium- and high-voltage substations","methodology":"Odporność na impulsowe pole magnetyczne","methodology_en":"Immunity to pulse magnetic field","parameters":[{"name":"Zakres","range":"do 1000 A/m"}],"parameters_en":[{"name":"Range","range":"do 1000 A/m"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na impulsowe pole magnetyczne\nZakres do 1000 A/m\nMetoda bezpośrednia","reference":"PN-EN 61000-4-9:2016-11","norm_bases":["PN-EN 61000-4-9:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Instalacje przemysłowe i kolejowe, elektrownie, podstacje średniego i wysokiego napięcia Odporność na impulsowe pole magnetyczne\nZakres do 1000 A/m\nMetoda bezpośrednia PN-EN 61000-4-9:2016-11 Instalacje przemyslowe i kolejowe, elektrownie, podstacje sredniego i wysokiego napiecia Odpornosc na impulsowe pole magnetyczne\nZakres do 1000 A/m\nMetoda bezposrednia PN-EN 61000-4-9:2016-11","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial and railway installations, power plants, medium- and high-voltage substations Immunity to pulse magnetic field Direct method Range PN-EN 61000-4-9:2016-11","parameters_zh":[{"name":"范围","range":"do 1000 A/m"}],"search_zh":"脉冲磁场抗扰度 直接法 范围 PN-EN 61000-4-9:2016-11","technique_zh":"直接法","methodology_zh":"脉冲磁场抗扰度"},{"_id":"6a5dc9adf1c10c8ce825aa23","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem AC","methodology_en":"Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment","parameters":[{"name":"Zakres","range":"do 300 V AC, 16 A"}],"parameters_en":[{"name":"Range","range":"do 300 V AC, 16 A"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem AC\nZakres do 300 V AC, 16 A\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-4-11:2020-11","norm_bases":["PN-EN IEC 61000-4-11:2020-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem AC\nZakres do 300 V AC, 16 A\nMetoda bezpośrednia PN-EN IEC 61000-4-11:2020-11 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia zasilania dla urzadzen zasilanych napieciem AC\nZakres do 300 V AC, 16 A\nMetoda bezposrednia PN-EN IEC 61000-4-11:2020-11","categories":["electronics"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment Direct method Range PN-EN IEC 61000-4-11:2020-11","parameters_zh":[{"name":"范围","range":"do 300 V AC, 16 A"}],"search_zh":"电气、电信与电子产品及设备 直接法 范围 PN-EN IEC 61000-4-11:2020-11","technique_zh":"直接法","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9adf1c10c8ce825aa24","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem AC","methodology_en":"Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment","parameters":[{"name":"Zakres","range":"do 300 V AC, 16 A"}],"parameters_en":[{"name":"Range","range":"do 300 V AC, 16 A"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem AC\nZakres do 300 V AC, 16 A\nMetoda bezpośrednia","reference":"PN-EN IEC 61000-6-2:2019-04","norm_bases":["PN-EN IEC 61000-6-2:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem AC\nZakres do 300 V AC, 16 A\nMetoda bezpośrednia PN-EN IEC 61000-6-2:2019-04 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia zasilania dla urzadzen zasilanych napieciem AC\nZakres do 300 V AC, 16 A\nMetoda bezposrednia PN-EN IEC 61000-6-2:2019-04","categories":["environment","electronics"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Immunity to voltage dips, short interruptions and supply voltage variations for AC-powered equipment Direct method Range PN-EN IEC 61000-6-2:2019-04","parameters_zh":[{"name":"范围","range":"do 300 V AC, 16 A"}],"search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 直接法 范围 PN-EN IEC 61000-6-2:2019-04","technique_zh":"直接法","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备"},{"_id":"6a5dc9adf1c10c8ce825aa25","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem DC","methodology_en":"Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment","parameters":[{"name":"Zakres","range":"do 425 V DC,"}],"parameters_en":[{"name":"Range","range":"do 425 V DC,"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem DC\nZakres do 425 V DC,\nMetoda bezpośrednia","reference":"PN-EN 61000-4-29:2004","norm_bases":["PN-EN 61000-4-29:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem DC\nZakres do 425 V DC,\nMetoda bezpośrednia PN-EN 61000-4-29:2004 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia zasilania dla urzadzen zasilanych napieciem DC\nZakres do 425 V DC,\nMetoda bezposrednia PN-EN 61000-4-29:2004","categories":["electronics"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment Direct method Range PN-EN 61000-4-29:2004","parameters_zh":[{"name":"范围","range":"do 425 V DC,"}],"search_zh":"电气、电信与电子产品及设备 直接法 范围 PN-EN 61000-4-29:2004","technique_zh":"直接法","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9adf1c10c8ce825aa26","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem DC","methodology_en":"Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment","parameters":[{"name":"Zakres","range":"do 425 V DC,"}],"parameters_en":[{"name":"Range","range":"do 425 V DC,"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem DC\nZakres do 425 V DC,\nMetoda bezpośrednia","reference":"PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia zasilania dla urządzeń zasilanych napięciem DC\nZakres do 425 V DC,\nMetoda bezpośrednia PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia zasilania dla urzadzen zasilanych napieciem DC\nZakres do 425 V DC,\nMetoda bezposrednia PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["electronics"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Immunity to voltage dips, short interruptions and supply voltage variations for DC-powered equipment Direct method Range PN-EN 50155:2018-01 | PN-EN 50155:2022-05","parameters_zh":[{"name":"范围","range":"do 425 V DC,"}],"search_zh":"安装于铁道车辆上的电子产品与装备 直接法 范围 PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","test_object_zh":"安装于铁道车辆上的电子产品与装备"},{"_id":"6a5dc9adf1c10c8ce825aa27","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne","test_object_en":"Industrial, scientific and medical equipment","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przemysłowe, naukowe i medyczne Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Urzadzenia przemyslowe, naukowe i medyczne Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["environment"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial, scientific and medical equipment Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","search_zh":"工业、科学与医疗设备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"test_object_zh":"工业、科学与医疗设备","methodology_zh":"传导骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa28","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12","norm_bases":["PN-EN 55016-2-1:2014-09","PN-EN 55016-2-1:2014-09/A1:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12","categories":["environment","electronics"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12","search_zh":"电气、电信与电子产品及设备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"传导骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa29","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","norm_bases":["PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN IEC 61000-6-4:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","categories":["environment","electronics"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备","methodology_zh":"传导骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa2a","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50155:2018-01","PN-EN 50155:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","categories":["environment","electronics"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","search_zh":"安装于铁道车辆上的电子产品与装备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50155:2018-01 | PN-EN 50155:2022-05","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"test_object_zh":"安装于铁道车辆上的电子产品与装备","methodology_zh":"传导骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa2b","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","norm_bases":["PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","categories":["environment"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","search_zh":"铁路行车控制与通信设备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"methodology_zh":"传导骚扰发射电平","test_object_zh":"铁路行车控制与通信设备"},{"_id":"6a5dc9adf1c10c8ce825aa2c","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią","test_object_en":"Stationary equipment of the power supply system","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Urzadzenia stacjonarne systemu zasilania energia Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["environment"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","search_zh":"供电系统固定设备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"methodology_zh":"传导骚扰发射电平","test_object_zh":"供电系统固定设备"},{"_id":"6a5dc9adf1c10c8ce825aa2d","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"},{"name":"Urządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"},{"name":"Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia","reference":"PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 55032:2015-09","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Poziom emisji zaburzeń przewodzonych\nZakres:\nZakres częstotliwości 9 kHz - 30 MHz\nUrządzenia 1-fazowe do 16A, 240V AC, 120V DC Urządzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezpośrednia PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Poziom emisji zaburzen przewodzonych\nZakres:\nZakres czestotliwosci 9 kHz - 30 MHz\nUrzadzenia 1-fazowe do 16A, 240V AC, 120V DC Urzadzenia 3-fazowe do 63A, 400/700V AC, 630V DC\nMetoda bezposrednia PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["environment"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Level of conducted disturbance emission Direct method Frequency range Single-phase devices up to 16A, 240V AC, 120V DC Three-phase devices up to 63A, 400/700V AC, 630V DC PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","search_zh":"多媒体设备 传导骚扰发射电平 直接法 频率范围 单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"},{"name":"单相设备至 16A、240V AC、120V DC；三相设备至 63A、400/700V AC、630V DC"}],"test_object_zh":"多媒体设备","methodology_zh":"传导骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa2e","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy","test_object_en":"Railway and urban rail vehicles and trolleybuses","methodology":"Poziom emisji zaburzeń przewodzonych","methodology_en":"Level of conducted disturbance emission","parameters":[{"name":"Zakres częstotliwości","range":"9 kHz - 30 MHz"}],"parameters_en":[{"name":"Frequency range","range":"9 kHz - 30 MHz"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń przewodzonych\nZakres częstotliwości 9 kHz - 30 MHz\nMetoda bezpośrednia","reference":"PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025","norm_bases":["PN-EN 55016-2-1:2014-09","PN-EN 55016-2-1:2014-09/A1:2017-12","PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PB-LA-21 wersja 10 z dnia 29.05.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy Poziom emisji zaburzeń przewodzonych\nZakres częstotliwości 9 kHz - 30 MHz\nMetoda bezpośrednia PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025 Pojazdy szynowe kolejowe i miejskie oraz trolejbusy Poziom emisji zaburzen przewodzonych\nZakres czestotliwosci 9 kHz - 30 MHz\nMetoda bezposrednia PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025","categories":["environment","automotive"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway and urban rail vehicles and trolleybuses Level of conducted disturbance emission Direct method Frequency range PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025","search_zh":"传导骚扰发射电平 直接法 频率范围 PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PB-LA-21 wersja 10 z dnia 29.05.2025","technique_zh":"直接法","parameters_zh":[{"name":"频率范围","range":"9 kHz - 30 MHz"}],"methodology_zh":"传导骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa2f","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia służące do sygnalizacji kolejowej: Latarnie sygnałowe sygnalizatorów kolejowych","test_object_en":"Equipment for railway signalling: Signal lanterns of railway signals","methodology":"Światłość kierunkowa, Użyteczny kąt rozwarcia wiązki świetlnej δ0,5, Chromatyczność barwy światła (0 – 1), Charakterystyki widmowe w zakresie, UV, VIS i NIR (200 – 1050) nm","methodology_en":"Directional luminous intensity, Useful beam angle δ0,5, Light colour chromaticity (0 – 1), Spectral characteristics in the range, UV, VIS and NIR (200 – 1050) nm","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Światłość kierunkowa, Użyteczny kąt rozwarcia wiązki świetlnej δ0,5, Chromatyczność barwy światła (0 – 1), Charakterystyki widmowe w zakresie, UV, VIS i NIR (200 – 1050) nm","reference":"Instrukcja PKP PLK S.A. Ie-123 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09","norm_bases":["Instrukcja PKP PLK S.A. Ie-123","PN-EN 13032-1+A1:2012","PN-EN 13032-4+A1:2019-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia służące do sygnalizacji kolejowej: Latarnie sygnałowe sygnalizatorów kolejowych Światłość kierunkowa, Użyteczny kąt rozwarcia wiązki świetlnej δ0,5, Chromatyczność barwy światła (0 – 1), Charakterystyki widmowe w zakresie, UV, VIS i NIR (200 – 1050) nm Instrukcja PKP PLK S.A. Ie-123 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 Urzadzenia sluzace do sygnalizacji kolejowej: Latarnie sygnalowe sygnalizatorow kolejowych Swiatlosc kierunkowa, Uzyteczny kat rozwarcia wiazki swietlnej δ0,5, Chromatycznosc barwy swiatla (0 – 1), Charakterystyki widmowe w zakresie, UV, VIS i NIR (200 – 1050) nm Instrukcja PKP PLK S.A. Ie-123 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Equipment for railway signalling: Signal lanterns of railway signals Directional luminous intensity, Useful beam angle δ0,5, Light colour chromaticity (0 – 1), Spectral characteristics in the range, UV, VIS and NIR (200 – 1050) nm Instrukcja PKP PLK S.A. Ie-123 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09"},{"_id":"6a5dc9adf1c10c8ce825aa30","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia służące do sygnalizacji kolejowej: Wskaźniki kolejowe podświetlane","test_object_en":"Equipment for railway signalling: Illuminated railway indicators","methodology":"Chromatyczność barwy światła (0 – 1), Luminacja","methodology_en":"Chromaticity of light colour (0 – 1), Luminance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Chromatyczność barwy światła (0 – 1), Luminacja","reference":"Instrukcja PKP PLK S.A. Ie-102 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 CIE 015:2018","norm_bases":["Instrukcja PKP PLK S.A. Ie-102","PN-EN 13032-1+A1:2012","PN-EN 13032-4+A1:2019-09 CIE 015:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia służące do sygnalizacji kolejowej: Wskaźniki kolejowe podświetlane Chromatyczność barwy światła (0 – 1), Luminacja Instrukcja PKP PLK S.A. Ie-102 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 CIE 015:2018 Urzadzenia sluzace do sygnalizacji kolejowej: Wskazniki kolejowe podswietlane Chromatycznosc barwy swiatla (0 – 1), Luminacja Instrukcja PKP PLK S.A. Ie-102 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 CIE 015:2018","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Equipment for railway signalling: Illuminated railway indicators Chromaticity of light colour (0 – 1), Luminance Instrukcja PKP PLK S.A. Ie-102 | PN-EN 13032-1+A1:2012 | PN-EN 13032-4+A1:2019-09 CIE 015:2018"},{"_id":"6a5dc9adf1c10c8ce825aa31","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Elementy wykonawcze, Centralnego Systemu, Dynamicznej Informacji, Pasażerskiej (CSDIP) i infrastruktury towarzyszącej","test_object_en":"Actuating elements of the Central Dynamic Passenger Information System (CSDIP) and accompanying infrastructure","methodology":"Luminacja, Równomierność luminacji","methodology_en":"Luminance, Luminance uniformity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Luminacja, Równomierność luminacji","reference":"Instrukcja PKP PLK S.A. Ipi-6 | PN-EN ISO 9241-305:2009","norm_bases":["Instrukcja PKP PLK S.A. Ipi-6","PN-EN ISO 9241-305:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy wykonawcze, Centralnego Systemu, Dynamicznej Informacji, Pasażerskiej (CSDIP) i infrastruktury towarzyszącej Luminacja, Równomierność luminacji Instrukcja PKP PLK S.A. Ipi-6 | PN-EN ISO 9241-305:2009 Elementy wykonawcze, Centralnego Systemu, Dynamicznej Informacji, Pasazerskiej (CSDIP) i infrastruktury towarzyszacej Luminacja, Rownomiernosc luminacji Instrukcja PKP PLK S.A. Ipi-6 | PN-EN ISO 9241-305:2009","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Actuating elements of the Central Dynamic Passenger Information System (CSDIP) and accompanying infrastructure Luminance, Luminance uniformity Instrukcja PKP PLK S.A. Ipi-6 | PN-EN ISO 9241-305:2009"},{"_id":"6a5dc9adf1c10c8ce825aa32","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne","test_object_en":"Industrial, scientific and medical equipment","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08","PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przemysłowe, naukowe i medyczne Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 Urzadzenia przemyslowe, naukowe i medyczne Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","categories":["environment"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial, scientific and medical equipment Level of radiated disturbance emission Range PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"工业、科学与医疗设备 辐射骚扰发射电平 范围 PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","test_object_zh":"工业、科学与医疗设备","methodology_zh":"辐射骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa33","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","norm_bases":["PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01","PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN IEC 61000-6-4:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","categories":["environment","electronics"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Level of radiated disturbance emission Range PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"电气、电信与电子产品及设备 辐射骚扰发射电平 范围 PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"辐射骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa34","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym","test_object_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","norm_bases":["PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01","PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN IEC 61000-6-4:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do użytku w środowisku przemysłowym Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne przeznaczone do uzytku w srodowisku przemyslowym Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","categories":["environment","electronics"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment intended for use in industrial environments Level of radiated disturbance emission Range PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"拟在工业环境中使用的电气、电信与电子产品及装备 辐射骚扰发射电平 范围 PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","test_object_zh":"拟在工业环境中使用的电气、电信与电子产品及装备","methodology_zh":"辐射骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa35","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym","test_object_en":"Electronic products and equipment mounted on railway rolling stock","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","norm_bases":["PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01","PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN IEC 61000-6-4:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektroniczne montowane na taborze kolejowym Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 Wyroby i wyposazenie elektroniczne montowane na taborze kolejowym Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","categories":["environment","electronics"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electronic products and equipment mounted on railway rolling stock Level of radiated disturbance emission Range PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"安装于铁道车辆上的电子产品与装备 辐射骚扰发射电平 范围 PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","test_object_zh":"安装于铁道车辆上的电子产品与装备","methodology_zh":"辐射骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa36","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia sterowania ruchem kolejowym i telekomunikacji","test_object_en":"Railway traffic control and telecommunications equipment","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","norm_bases":["PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01","PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN IEC 61000-6-4:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sterowania ruchem kolejowym i telekomunikacji Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 Urzadzenia sterowania ruchem kolejowym i telekomunikacji Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway traffic control and telecommunications equipment Level of radiated disturbance emission Range PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"铁路行车控制与通信设备 辐射骚扰发射电平 范围 PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","methodology_zh":"辐射骚扰发射电平","test_object_zh":"铁路行车控制与通信设备"},{"_id":"6a5dc9adf1c10c8ce825aa37","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia stacjonarne systemu zasilania energią","test_object_en":"Stationary equipment of the power supply system","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","norm_bases":["PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01","PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN IEC 61000-6-4:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia stacjonarne systemu zasilania energią Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12 Urzadzenia stacjonarne systemu zasilania energia Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","categories":["environment"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Stationary equipment of the power supply system Level of radiated disturbance emission Range PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"供电系统固定设备 辐射骚扰发射电平 范围 PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN IEC 61000-6-4:2019-12","methodology_zh":"辐射骚扰发射电平","test_object_zh":"供电系统固定设备"},{"_id":"6a5dc9adf1c10c8ce825aa38","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Poziom emisji zaburzeń promieniowanych","methodology_en":"Level of radiated disturbance emission","parameters":[{"name":"Zakres","range":"30 MHz – 6 GHz"}],"parameters_en":[{"name":"Range","range":"30 MHz – 6 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz","reference":"PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 55032:2015-09","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Poziom emisji zaburzeń promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Poziom emisji zaburzen promieniowanych\nZakres 30 MHz – 6 GHz PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Level of radiated disturbance emission Range PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","parameters_zh":[{"name":"范围","range":"30 MHz – 6 GHz"}],"search_zh":"多媒体设备 辐射骚扰发射电平 范围 PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"辐射骚扰发射电平"},{"_id":"6a5dc9adf1c10c8ce825aa39","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy","test_object_en":"Railway and urban rail vehicles and trolleybuses","methodology":"Poziom emisji zaburzeń promieniowanych w zakresie częstotliwości: 150 kHz – 1 GHz","methodology_en":"Level of radiated disturbance emission in the frequency range: 150 kHz – 1 GHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom emisji zaburzeń promieniowanych w zakresie częstotliwości: 150 kHz – 1 GHz","reference":"PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06","norm_bases":["PN-EN 50121-3-1:2017-05","PN-EN 50121-3-1:2017-05/A1:2019-07","PN-EN 50121-2:2015-10","PN-EN 50121-2:2017-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy Poziom emisji zaburzeń promieniowanych w zakresie częstotliwości: 150 kHz – 1 GHz PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06 Pojazdy szynowe kolejowe i miejskie oraz trolejbusy Poziom emisji zaburzen promieniowanych w zakresie czestotliwosci: 150 kHz – 1 GHz PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06","categories":["environment","automotive"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway and urban rail vehicles and trolleybuses Level of radiated disturbance emission in the frequency range: 150 kHz – 1 GHz PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06"},{"_id":"6a5dc9adf1c10c8ce825aa3a","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy, środowisko kolejowe","test_object_en":"Railway and urban rail vehicles and trolleybuses, railway environment","methodology":"Poziom pola magnetycznego DC","methodology_en":"DC magnetic field level","parameters":[{"name":"Zakres","range":"100 μT – 20 T"}],"parameters_en":[{"name":"Range","range":"100 μT – 20 T"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom pola magnetycznego DC\nZakres 100 μT – 20 T","reference":"PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10","norm_bases":["PN-EN 50500:2008","PN-EN 50500:2008/A1:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy, środowisko kolejowe Poziom pola magnetycznego DC\nZakres 100 μT – 20 T PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10 Pojazdy szynowe kolejowe i miejskie oraz trolejbusy, srodowisko kolejowe Poziom pola magnetycznego DC\nZakres 100 μT – 20 T PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10","categories":["environment","automotive"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway and urban rail vehicles and trolleybuses, railway environment DC magnetic field level Range PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10","parameters_zh":[{"name":"范围","range":"100 μT – 20 T"}],"search_zh":"范围 PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10"},{"_id":"6a5dc9adf1c10c8ce825aa3b","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy, środowisko kolejowe","test_object_en":"Railway and urban rail vehicles and trolleybuses, railway environment","methodology":"Poziom pola magnetycznego AC","methodology_en":"AC magnetic field level","parameters":[{"name":"Zakres","range":"100 nT – 32 T"},{"name":"w zakresie częstotliwości od 5 Hz","range":"do 20 kHz"}],"parameters_en":[{"name":"Range","range":"100 nT – 32 T"},{"name":"in the frequency range from 5 Hz","range":"do 20 kHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom pola magnetycznego AC\nZakres:\nZakres 100 nT – 32 T\nw zakresie częstotliwości od 5 Hz do 20 kHz","reference":"PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10","norm_bases":["PN-EN 50500:2008","PN-EN 50500:2008/A1:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe i miejskie oraz trolejbusy, środowisko kolejowe Poziom pola magnetycznego AC\nZakres:\nZakres 100 nT – 32 T\nw zakresie częstotliwości od 5 Hz do 20 kHz PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10 Pojazdy szynowe kolejowe i miejskie oraz trolejbusy, srodowisko kolejowe Poziom pola magnetycznego AC\nZakres:\nZakres 100 nT – 32 T\nw zakresie czestotliwosci od 5 Hz do 20 kHz PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10","categories":["environment","automotive"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway and urban rail vehicles and trolleybuses, railway environment AC magnetic field level Range in the frequency range from 5 Hz PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10","parameters_zh":[{"name":"范围","range":"100 nT – 32 T"},{"name":"频率范围自 5 Hz 起","range":"do 20 kHz"}],"search_zh":"范围 频率范围自 5 Hz 起 PN-EN 50500:2008 | PN-EN 50500:2008/A1:2015-10"},{"_id":"6a5dc9adf1c10c8ce825aa3c","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby telekomunikacyjne: - radiotelefony przenośne (częstotliwość pracy do 1000 MHz, moc wyjściowa w.cz. do 50 W)","test_object_en":"Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W)","methodology":"Moc w.cz. i zdolność do pracy po narażeniach klimatycznych","methodology_en":"RF power and ability to operate after climatic exposure","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc w.cz. i zdolność do pracy po narażeniach klimatycznych","reference":"PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2 | PB-LA-04 wersja 11 z dnia 20.12.2018 r.","norm_bases":["PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2","PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2","PB-LA-04 wersja 11 z dnia 20.12.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby telekomunikacyjne: - radiotelefony przenośne (częstotliwość pracy do 1000 MHz, moc wyjściowa w.cz. do 50 W) Moc w.cz. i zdolność do pracy po narażeniach klimatycznych PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2 | PB-LA-04 wersja 11 z dnia 20.12.2018 r. Wyroby telekomunikacyjne: - radiotelefony przenosne (czestotliwosc pracy do 1000 MHz, moc wyjsciowa w.cz. do 50 W) Moc w.cz. i zdolnosc do pracy po narazeniach klimatycznych PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2 | PB-LA-04 wersja 11 z dnia 20.12.2018 r.","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) RF power and ability to operate after climatic exposure PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 6.4, 6.5, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 5.4, 5.5, 7.1, 7.2 | PB-LA-04 wersja 11 z dnia 20.12.2018 r."},{"_id":"6a5dc9adf1c10c8ce825aa3d","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Wyroby telekomunikacyjne: - radiotelefony przenośne (częstotliwość pracy do 1000 MHz, moc wyjściowa w.cz. do 50 W)","test_object_en":"Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W)","methodology":"Użytkowy czas pracy i zdolność do pracy przy określonym stosunku nadawanie: odbiór: nasłuch","methodology_en":"Operating time and operating capability at a specified transmit: receive: standby ratio","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Użytkowy czas pracy i zdolność do pracy przy określonym stosunku nadawanie: odbiór: nasłuch","reference":"PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2 | PB-LA-05 wersja 9 z dnia 30.03.2016 r.","norm_bases":["PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2","PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2","PB-LA-05 wersja 9 z dnia 30.03.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby telekomunikacyjne: - radiotelefony przenośne (częstotliwość pracy do 1000 MHz, moc wyjściowa w.cz. do 50 W) Użytkowy czas pracy i zdolność do pracy przy określonym stosunku nadawanie: odbiór: nasłuch PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2 | PB-LA-05 wersja 9 z dnia 30.03.2016 r. Wyroby telekomunikacyjne: - radiotelefony przenosne (czestotliwosc pracy do 1000 MHz, moc wyjsciowa w.cz. do 50 W) Uzytkowy czas pracy i zdolnosc do pracy przy okreslonym stosunku nadawanie: odbior: nasluch PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2 | PB-LA-05 wersja 9 z dnia 30.03.2016 r.","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Telecommunication products: - portable radiotelephones (operating frequency up to 1000 MHz, RF output power up to 50 W) Operating time and operating capability at a specified transmit: receive: standby ratio PN-ETSI EN 300 086-1 V1.2.1: 2005; wg pkt. 5.1, 8.2 | PN-ETSI EN 300 086-1 V1.4.1: 2011; wg pkt. 7.1, 7.2 | PB-LA-05 wersja 9 z dnia 30.03.2016 r."},{"_id":"6a5dc9adf1c10c8ce825aa3e","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Pojazdy szynowe kolejowe: - radiotelefon z funkcją radiostopu","test_object_en":"Railway rail vehicles: - radiotelephone with radio-stop function","methodology":"","methodology_en":null,"parameters":[{"name":"Realizacja funkcji związanych z zadziałaniem radiostopu"},{"name":"Rejestracja zdarzeń związanych z zadziałaniem radiostopu"}],"parameters_en":[{"name":"Performance of functions related to the activation of the radio-stop"},{"name":"Recording of events related to the activation of the radio-stop"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nRealizacja funkcji związanych z zadziałaniem radiostopu\nRejestracja zdarzeń związanych z zadziałaniem radiostopu","reference":"PB-LA-07 wersja 7 z dnia 28.07.2017 r.","norm_bases":["PB-LA-07 wersja 7 z dnia 28.07.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojazdy szynowe kolejowe: - radiotelefon z funkcją radiostopu \nZakres:\nRealizacja funkcji związanych z zadziałaniem radiostopu\nRejestracja zdarzeń związanych z zadziałaniem radiostopu PB-LA-07 wersja 7 z dnia 28.07.2017 r. Pojazdy szynowe kolejowe: - radiotelefon z funkcja radiostopu \nZakres:\nRealizacja funkcji zwiazanych z zadzialaniem radiostopu\nRejestracja zdarzen zwiazanych z zadzialaniem radiostopu PB-LA-07 wersja 7 z dnia 28.07.2017 r.","categories":["automotive"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Railway rail vehicles: - radiotelephone with radio-stop function Performance of functions related to the activation of the radio-stop Recording of events related to the activation of the radio-stop PB-LA-07 wersja 7 z dnia 28.07.2017 r."},{"_id":"6a5dc9adf1c10c8ce825aa3f","lab_id":"69ad52a3de79e566650fb1af","country":"PL","accr_number":"AB 310","accr_body":"PCA","test_object":"Instalacje radiokomunikacyjne wzdłuż szlaku kolejowego","test_object_en":"Radiocommunication installations along the railway line","methodology":"Natężenie pola elektrycznego w paśmie GSM-R","methodology_en":"Electric field strength in the GSM-R band","parameters":[{"name":"Zakres","range":"921 MHz - 960 MHz"}],"parameters_en":[{"name":"Range","range":"921 MHz - 960 MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego w paśmie GSM-R\nZakres 921 MHz - 960 MHz","reference":"PB-LA-17 wersja 4 z 26.04.2023 r.","norm_bases":["PB-LA-17 wersja 4 z 26.04.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Instalacje radiokomunikacyjne wzdłuż szlaku kolejowego Natężenie pola elektrycznego w paśmie GSM-R\nZakres 921 MHz - 960 MHz PB-LA-17 wersja 4 z 26.04.2023 r. Instalacje radiokomunikacyjne wzdluz szlaku kolejowego Natezenie pola elektrycznego w pasmie GSM-R\nZakres 921 MHz - 960 MHz PB-LA-17 wersja 4 z 26.04.2023 r.","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Radiocommunication installations along the railway line Electric field strength in the GSM-R band Range PB-LA-17 wersja 4 z 26.04.2023 r.","parameters_zh":[{"name":"范围","range":"921 MHz - 960 MHz"}],"search_zh":"范围 PB-LA-17 wersja 4 z 26.04.2023 r."}],"has_pdf":true}