🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT SZTUCZNEJ PL

PCA AB 261 • Katowice, Poland • 167 methods

Electronics & EMCConstructionAutomotiveMaterials & polymers

SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT SZTUCZNEJ is a laboratory accredited by PCA under number AB 261 (Katowice, Poland). Its accreditation scope covers 167 test methods in the following areas: Electronics & EMC, Construction, Automotive, Materials & polymers. Test objects include: Electrical and electronic equipment (testing performed at the labor…, Cables and wires with rated voltage up to 18/30 kV, outer diameter…, Electrotechnical, telecommunications and electronic products and co…, Gas detectors, Electrical apparatus for the detection of carbon mon…. Most frequently used techniques: Method: direct method, Direct method, Needle-flame test method.

At a glance

  • Accreditation number: PCA AB 261
  • Methods in scope: 167
  • Types of test objects: 29
  • Techniques used: 4
  • City: Katowice, Poland
Accreditation number
AB 261
Accreditation body
PCA
Address
INTELIGENCJI I CYBERBEZPIECZEŃSTWA, CENTRUM BADAŃ I CERTYFIKACJI, ZESPÓŁ LABORATORIÓW BADAWCZYCH, ul. Leopolda 31
City
Katowice, Poland

What this laboratory tests (29)

Analytical techniques used (4)

Accreditation scope — test methods (167)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrostatic discharge
Test level (0,2 - 30) kV
Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06
2 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to radiated radio-frequency electromagnetic field
Frequency (0,08 - 6) GHz Testing in a semi-anechoic chamber SAC
Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06
3 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrical fast transients/bursts
Test level (0,25 - 5,5) kV at a repetition frequency of 5 kHz and 100 kHz
Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06
4 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to surges
Test level (0,5 - 6) kV
Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06
5 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to conducted disturbances induced by radio-frequency fields
Frequency (0,01 - 400) MHz Test level (0,1 - 20) V
Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06
6 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to power-frequency magnetic field
Test level (1 - 300) A/m
Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06
7 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to pulse magnetic field, Test level: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11
8 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations, Test level: 0% UT, 40% UT, 70% UT, 80% UT Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06
9 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory waves
Test level (0,25 - 6) kV
Ζ | PN-EN 61000-4-12:2017-12
10 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations occurring at the DC power port, Test level: (0% - 120%) UT Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06
11 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to radio fields in close proximity
Frequency (0,009 - 26) MHz
Ζ | PN-EN 61000-4-39:2017-07
12 Electrical and electronic equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11
13 Electrical and electronic equipment Electromagnetic field strength
Frequency (0,0001 - 18) GHz and at the installation site / IN SITU Frequency (0,03 - 1) GHz
Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01
14 Industrial, scientific and medical (ISM) radio-frequency equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08
15 Industrial, scientific and medical (ISM) radio-frequency equipment Electromagnetic field strength
Frequency (0,0001 - 18) GHz and at the installation site / IN SITU Frequency (0,03 - 1) GHz
Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08
16 Information technology equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07
17 Information technology equipment Disturbance voltage at telecommunication ports
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55022:2000 p. 9.6 | PN-EN 55022:2000/A2:2004 | PN-EN 55022:2000/A1:2003 | PN-EN 55022:2000/AC:2005
18 Information technology equipment Electromagnetic field strength
Frequency (0,0001 - 18) GHz
Ζ | PN-EN 55022:2011 p. 10 | PN-EN 55022:2011/Ap1:2013-07
19 Multimedia equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
20 Multimedia equipment Electromagnetic field strength
Frequency (0,0001 - 18) GHz
Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
21 Measuring relays and protection equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06
22 Measuring relays and protection equipment Electromagnetic field strength
Frequency (0,0001 - 18) GHz
Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06
23 Household appliances, electric tools and similar apparatus Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN IEC 55014-1:2021-08
24 Household appliances, electric tools and similar apparatus Disturbance voltage at telecommunication ports
Frequency (0,009 - 30) MHz
Ζ | PN-EN IEC 55014-1:2021-08
25 Household appliances, electric tools and similar apparatus Electromagnetic field strength
Frequency (0,0001 - 18) GHz
Ζ | PN-EN IEC 55014-1:2021-08
26 Electrical lighting and similar equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07
27 Electrical lighting and similar equipment Electromagnetic field strength
Frequency (0,0001 - 18) GHz
Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07
28 Electrical and electronic equipment Current harmonics and interharmonics
Range (2 - 40) harmonicznej
Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012
29 Electrical and electronic equipment Voltage fluctuations and flicker Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01
30 Electrical and electronic components used in the Automotive industry Immunity to transient disturbances occurring in vehicle on-board electrical systems (pulses: 1, 2a, 2b, 3a, 3b and 4) Ζ | ISO 7637-2:2011 | ISO 7637-3:2007 | ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10
31 Electrical and electronic components used in the Automotive industry Immunity to radiated radio-frequency electromagnetic field
Frequency (0,2 - 6) GHz
Ζ | ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9
32 Electrical and electronic components used in the Automotive industry Immunity to conducted disturbances, induced by radio-frequency fields (BCI)
Frequency (0,1 - 400) MHz Test level (1 - 109) dB (μA)
Ζ | ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9
33 Electrical and electronic components used in the Automotive industry Immunity to narrowband radio disturbances from portable transmitters
Frequency (0,026 - 6) GHz
Ζ | ISO 11452-9:2021-10
34 Electrical and electronic components used in the Automotive industry Immunity to electrostatic discharge
Test level (0,2 - 30) kV
Ζ | ISO 10605:2023
35 Electrical and electronic components used in the Automotive industry Disturbance voltage at the mains terminals
Frequency (0,1 - 108) MHz
Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8
36 Electrical and electronic components used in the Automotive industry Electromagnetic field strength (at a distance of 1 m)
Frequency (0,0001 - 18) GHz
Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8
37 Electrical and electronic components used in the Automotive industry Disturbance voltage at the supply terminals (transients in on-board vehicle electrical systems with 12 V and 24 V supply voltage) Ζ | ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10
38 Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Immunity to radiated disturbances, electric field
Frequency (0,08 - 1) GHz Test level (1 - 20) V/m Frequency (1 - 4) GHz Test level (1 - 50) V/m
Ζ NO-06-A500:2012 p. 3.17
39 Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Immunity to conducted disturbances, injected into cables
Frequency (0,01 - 200) MHz Test level (20 - 109) dB μA
Ζ NO-06-A500:2012 p. 3.9
40 Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Conducted emissions, power supply leads
Frequency (0,01 - 10) MHz
Ζ NO-06-A500:2012 p. 3.2
41 Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Radiated emissions, electric field
Frequency (0,00001 - 18) GHz
Ζ NO-06-A500:2012 p. 3.14
42 Test object/product Type of activity/tested characteristics/methods Dokumenty odniesienia
43 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrostatic discharge
Test level (0,2 - 30) kV
Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06
44 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to radiated radio-frequency electromagnetic field
Frequency (0,08 - 6) GHz Testing in a semi-anechoic chamber SAC
Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06
45 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrical fast transients/bursts
Test level (0,25 - 5,5) kV at a repetition frequency of 5 kHz and 100 kHz
Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06
46 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to surges
Test level (0,5 - 6) kV
Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06
47 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to conducted disturbances induced by radio-frequency fields
Frequency (0,01 - 400) MHz Test level (0,1 - 20) V
Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06
48 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to power-frequency magnetic field
Test level (1 - 1000) A/m
Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06
49 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to pulse magnetic field, Test level: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11
50 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory magnetic field
Test level (10 - 100) A/m
Ζ | PN-EN 61000-4-10:2017-04
51 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations
Test level (0% - 100%) UT
Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06
52 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory waves
Test level (0,25 - 6) kV
Ζ | PN-EN 61000-4-12:2017-12
53 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to low-frequency disturbances Ζ | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05
54 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to conducted common mode disturbances
Frequency (0 - 150) kHz
Ζ | PN-EN 61000-4-16:2016-05
55 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to ripple on the DC input power port Ζ | PN-EN 61000-4-17:2004 | PN-EN 61000-4-17:2004/A1:2006 | PN-EN 61000-4-17:2004/A2:2011 | PN-EN 60255-26:2014-01 p. 7.2.12 | PN-EN 60255-26:2014-01/AC:2014-06
56 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory wave Ζ | PN-EN IEC 61000-4-18:2019-08 | PN-EN IEC 61000-4-18:2019-08/AC:2019-12 | PN-EN 60255-26:2014-01 p. 7.2.6 | PN-EN 60255-26:2014-01/AC:2014-06
57 Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations occurring at the DC power port
Test level (0 - 120)% UT
Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06
58 Electrical and electronic equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11
59 Electrical and electronic equipment Electromagnetic field strength
Frequency (0,0001 - 6) GHz and at the installation site / IN SITU Frequency (0,03 - 1) GHz
Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01
60 Industrial, scientific and medical (ISM) radio-frequency equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08
61 Industrial, scientific and medical (ISM) radio-frequency equipment Electromagnetic field strength
Frequency (0,0001 - 6) GHz and at the installation site / IN SITU Frequency (0,03 - 1) GHz
Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08
62 Information technology equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07
63 Information technology equipment Disturbance voltage at telecommunication ports
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07
64 Information technology equipment Electromagnetic field strength
Frequency (0,03 - 6) GHz
Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07
65 Multimedia equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
66 Multimedia equipment Disturbance voltage at telecommunication ports
Frequency (0,009 - 30) MHz
Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
67 Multimedia equipment Electromagnetic field strength
Frequency (0,0001 - 6) GHz
Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05
68 Measuring relays and protection equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06
69 Measuring relays and protection equipment Electromagnetic field strength
Frequency (0,0001 - 6) GHz
Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06
70 Household appliances, electric tools and similar apparatus Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN IEC 55014-1:2021-08
71 Household appliances, electric tools and similar apparatus Disturbance voltage at telecommunication ports
Frequency (0,009 - 30) MHz
Ζ | PN-EN IEC 55014-1:2021-08
72 Household appliances, electric tools and similar apparatus Electromagnetic field strength
Frequency (0,0001 - 6) GHz
Ζ | PN-EN IEC 55014-1:2021-08
73 Household appliances, electric tools and similar apparatus Disturbance power
Frequency (0,03 - 1) GHz
Ζ | PN-EN 55016-2-2:2011 | PN-EN 55016-2-2:2011/Ap1:2013-06 | PN-EN IEC 55014-1:2021-08
74 Electrical lighting and similar equipment Disturbance voltage at the mains terminals
Frequency (0,009 - 30) MHz
Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07
75 Electrical lighting and similar equipment Electromagnetic field strength
Frequency (0,0001 - 6) GHz
Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07
76 Electrical and electronic equipment Current harmonics and interharmonics
Range (2 - 40) harmonicznej
Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012
77 Electrical and electronic equipment Voltage fluctuations and flicker Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01
78 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of the insulation, sheath or covering to pressure at elevated temperature Ζ | PN-EN 60811-508:2012 | PN-EN 60811-508:2012/A1:2018-02 | PN-EN 60811-508:2012/A2:2024-03 | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002
79 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Verification of the construction and dimensions of cable and wire components Ζ | PN-EN 60851-2:2010 | PN-EN 60851-2:2010/A1:2015-09 | PN-EN 60851-2:2010/A2:2019-12 | PN-EN 60811-201:2012 | PN-EN 60811-201:2012/A1:2018-02 | PN-EN 60811-201:2012/A2:2024-03 | PN-EN 60811-202:2012 | PN-EN 60811-202:2012/A1:2018-02 | PN-EN 60811-202:2012/A2:2024-03 | PN-EN 60811-203:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6) | PN-E-04160-19:1992 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011
80 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance to flame spread Ζ | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010
81 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Transition resistance between the screen and the protective core in rubber-sheathed cables Ζ | PN-E-04160-68:1988 | PN-G-42010:1997
82 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Susceptibility to winding
range (od - 70 do +250) °C
Ζ | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 | PN-EN 60811-504:2012 | PN-EN 60811-509:2012 | PN-EN 60811-509:2012/A1:2018-02
83 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Longitudinal watertightness (water penetration) Ζ | PN-HD 605-S3:2020-05 | IEC 60502-2:2014 zał. F | IEC 60502-2:2014/AMD1:2024
84 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Permanent elongation at elevated temperature
range do 150 °C
Ζ | PN-EN 60811-507:2012 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002
85 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of cables to repeated bending range: nominal conductor cross-section (0,35 - 4) mm2 Ζ | PN-E-04160-25:1989 | PN-E-04160-25:1989/Az1:1998 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011
86 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of cores and other metal elements
range (10-5 - 105) Ω
Ζ | PN-E-04160-70:1983 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60228:2025-02 | PN-EN 50289-1-2:2007
87 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Mass loss of PVC insulation and sheaths Ζ | PN-EN 60811-409:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006
88 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of the cable or wire to impact range: down to – 70 °C Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 | PN-EN 60811-506:2012 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002
89 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of the cable to repeated bending with simultaneous twisting range: nominal cross-section (6 - 120) mm2 Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996
90 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Water absorption through insulation and sheath Ζ | PN-EN 60811-402:2012 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002
91 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Shrinkage of the insulation and sheath Ζ | PN-EN 60811-502:2012 | PN-EN 60811-503:2012 | PN-EN 60811-503:2012/A1:2024-03 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.4.4.1
92 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Thermal endurance of the insulation and sheath Ζ | PN-EN 60811-405:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006
93 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance to high temperature Ζ | PN-HD 605-S3:2020-05
94 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Withstand of the test voltage
test voltage range do 50 kV AC i 6 kV DC
Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 50289-1-3:2007
95 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Volume resistance and volume resistivity of insulation Ζ | PN-E-04160-73:1983 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 50289-1-4:2007
96 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Surface resistance of the coating Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011
97 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance to long-term direct current Ζ | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011
98 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Heating (temperature rise) Ζ | PN-E-04160-69:1988
99 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Effective capacitance Ζ | PN-E-04160-77:1973 | PN-EN 50289-1-5:2008
100 Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Capacitance asymmetry PN-E-04160-78:1973
101 Round and rectangular enamelled winding wires, diameter up to 5 mm, cross-section up to 15 mm x 10 mm Flexibility and adhesion., Mandrel winding test Ζ | PN-EN IEC 60851-3:2024-05 p. 6.2
102 Round and rectangular enamelled winding wires, diameter up to 5 mm, cross-section up to 15 mm x 10 mm Resistance to thermal shock Ζ | PN-EN 60851-6:2013-03 | PN-EN 60851-6:1998 | PN-EN 60851-6:1998/A2:2005
103 Plastics, rubber, metals Mechanical properties under static tension:
tensile strength elongation at break before and after thermal ageing and after exposure to oil range: force (10 - 500) N and (1 - 10) kN percentage elongation do 1250%
Ζ | PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-3:1998 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 | PN-EN 60811-404:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-EN 60811-1-2:1999 | PN-EN 60811-1-2:1999/A2:2002 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 | PN-ISO 37:2007 | PN-ISO 37:2007/AC1:2008 | PN-E-04160-11:1973 | PN-EN ISO 6892-1:2010 | PN-EN ISO 6892-1:2010/Ap1:2015-02
104 Plastics, rubber, metals
tensile strength elongation at break maximum force 10 kN, percentage elongation do 1250%
Ζ | PN-EN IEC 60851-3:2024-05 p. 4 | PN-EN 50289-3-2:2002
105 Plastics, rubber Ignitability by the oxygen index method Ζ | PN-E-04160-56:1990 | PN-EN ISO 4589-2:2006 | PN-EN ISO 4589-2:2006/A1:2006
106 Electrotechnical products Electric strength
Range do 75 kV Alternating voltage test
Ζ | PN-EN 60243-1:2013-12 | PN-EN 60243-1:2002
107 Electrotechnical products Fire hazard: Test methods with a nominal test flame: 1 kW, 500 W, 50 W, Ζ | PN-EN 60695-11-2:2017-11 | PN-EN 60695-11-20:2002 | PN-EN 60695-11-20:2002/A1:2005 | PN-EN 60695-11-20:2015-08 | PN-EN 60695-11-20:2015-08 /AC:2017-01 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014/AC:2017-08 | PN-EN 60695-11-10:2002 | PN-EN 60695-11-10:2002/A1:2005 | PN-EN ISO 9773:2025-03
108 Electrotechnical products Fire hazard: Needle-flame test method Ζ | PN-EN 60695-11-5:2017-08
109 Electrotechnical products Resistance to heat (ball pressure test) Ζ | PN-EN 60695-10-2:2014-10 | PN-EN 60695-10-2:2005
110 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to cold (Test A), min. temp. (-70±2) °C Ζ | PN-EN 60068-2-1:2009 | PN-G 50003:2003 | PN-G 50006:1997
111 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to dry heat (Test B) up to temp. (180±2) °C Ζ | PN-EN 60068-2-2:2009 | PN-G 50003:2003 | PN-G 50006:1997
112 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to steady-state damp heat (Test Cab) in the temperature range up to (95±2) °C and relative humidity up to (93±3)% Ζ | PN-EN 60068-2-78:2013-11 | PN-EN 60068-2-78:2007 | PN-G 50003:2003 | PN-G 50006:1997
113 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to cyclic damp heat (Test Db) in the temperature range up to (55±2) °C and relative humidity up to (95±3)% Ζ | PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1
114 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test N: Change of temperature Ζ | PN-EN IEC 60068-2-14:2024-04
115 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Combined tests, temperature or temperature and humidity in combination with low air pressure in
range (20 – 950) mBar
Ζ | PN-EN 60068-2-39:2016-04 | PN-EN 60068-2-39:2016-04 /Ap1:2019-04
116 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test Z/AM: combined cold/ low air pressure test in the range: (20 – 950) mBar Ζ | PN-EN 60068-2-40:2002
117 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test Z/BM: combined dry heat/ low air pressure test in
range (20 – 950) mBar
Ζ | PN-EN 60068-2-41:2002
118 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test M: low air pressure (underpressure) in the range: (11 – 99) kPa (110 – 990) mbar Ζ | PN-EN IEC 60068-2-13:2021-11
119 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to shock (Test Ea) [shock]
Maximum acceleration (depending on the mass of the tested object and the direction exposure) do 264 g, z wyłączeniem tests for 2500 [m/s2]/1 [ms] Mass of the object do 500 kg Peak displacement amplitude: up to ±38,1 mm
Ζ | PN-EN 60068-2-27:2009 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 | PN-EN 60255-21-2:2000
120 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to vibration (Test Fc) (sinusoidal) [vibration]
Frequency range (5 - 2000) Hz, Maximum acceleration (depending on the mass of the tested object and the direction exposure) do 13 g Mass of the object do 500 kg Peak displacement amplitude: up to ±38,1 mm
Ζ | PN-EN 60068-2-6:2008 | PN-EN 60255-21-1:1999 | PN-EN IEC 60598-1:2025-04 p. 7.20.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 | PN-G-50006:1997
121 Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to broadband random vibration (Test Fh)
Frequency range (5 - 2000) Hz, Maximum acceleration (depending on the mass of the tested object and the direction exposure) do 100 g, Mass of the object do 800 kg Peak displacement amplitude: up to ±38,1 mm
Ζ | PN-EN 60068-2-64:2008 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010
122 Dimensions for objects l./w./h. 750 mm/750 mm /600 mm (for IP5X and IP6X testing), Dimensions for the working space diameter/ height 1530 mm/ 1250 mm (for IPX7 and IPX8 testing) Testing / verification of the IP degree of protection:
IP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 to IPX8 protection against water; IPX9k protection against water;
Ζ | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | ISO 20653:2013
123 Rolling stock equipment Resistance and endurance to shock (Test Ea) [shock]
Mass of the object do 500 kg
Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10
124 Rolling stock equipment Resistance and endurance to random vibration (Test Fh)
Mass of the object do 500 kg
Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10
125 Rolling stock equipment Cold resistance Ζ | PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6 | PN-EN 60068-2-1:2009
126 Rolling stock equipment Resistance to dry heat Ζ | PN-EN 50155:2022-05 p. 13.4.5 | PN-EN 60068-2-2:2009
127 Rolling stock equipment Damp heat resistance Ζ | PN-EN 50155:2022-05 p. 13.4.8 | PN-EN 60068-2-30:2008
128 Rolling stock equipment Insulation testing Ζ | PN-EN 50155:2022-05 p. 13.4.7
129 Electrical, telecommunications and electronic products and equipment Verification of the resistance of the enclosure to mechanical impacts, Hammer tests: Ehb Ζ | PN-EN 60068-2-75:2015-01 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60598-1:2025-04 p. 7.13.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08
130 Electrical, telecommunications and electronic products and equipment Verification of the degree of protection against mechanical impacts (IK code) Hammer tests: Ehb
Range do IK 06
Ζ | PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 62262:2003 | PN-EN 62262:2003/Ap1:2022-01 | PN-EN 62262:2003/A1:2022-06
131 Electrical, telecommunications and electronic products and equipment Immersion in water Ζ | PN-EN 50604-1:2017-02, p. 8.3 | PN-EN 50604-1:2017-02/A1:2022-05
132 Electrical, telecommunications and electronic products and equipment Resistance to reduced pressure [altitude simulation] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)
133 Electrical, telecommunications and electronic products and equipment Resistance to temperature changes Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)
134 Electrical, telecommunications and electronic products and equipment Vibration resistance [vibration] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)
135 Electrical, telecommunications and electronic products and equipment Resistance to shocks [shock] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)
136 Electrical, telecommunications and electronic products and equipment Resistance to external short circuit Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)
137 Electrical, telecommunications and electronic products and equipment Resistance to overcharging Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)
138 Electrical, telecommunications and electronic products and equipment Verification of resistance to repeated free fall. Test Ec. Procedure 2. Ζ | PN-EN 60068-2-31 p. 5.3 | PN-EN IEC 60598-1:2025-04 p. 7.13.4 | PN-EN IEC 60598-1:2025-04 /A11:2025-08 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60335-1:2024-04 /A11:2024-10
139 Mining electrical equipment Clearances, Protection against direct contact, Operation, Correct operation of contacts for connectors and couplers, Heating of equipment (temperature rise) with current up to 10 kA and temperature up to 200 °C Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003
140 Mining electrical equipment, Mining automation and telecommunication equipment. Insulation resistance range up to 2,99 TΩ, measuring voltage (50 - 2500) V, Dielectric strength of insulation, test voltage up to 50 kV AC and DC, test transformer power up to 5 kVA Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997
141 Mining electrical equipment up to 6kV Clearances, Protection against direct contact, Correct operation of contacts for connectors and couplers, Temperature (temperature rise) Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003
142 Mining electrical equipment, Mining automation and telecommunication equipment Insulation resistance range up to 2,99 TΩ, measuring voltage (50 - 2500) V
Direct measurement Dielectric strength of the insulation test voltage do 50 kV AC, power of the test transformer do 5 kVA Measurement with sinusoidal alternating voltage
Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997
143 Audio/video, information technology and telecommunications equipment Determination of accessible conductive parts Ζ | PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3 | PN-EN IEC 62368-1:2024-06/A11:2025-01
144 Audio/video, information technology and telecommunications equipment Humidity conditioning Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.8 | PN-EN IEC 62368-1:2024-06/A11:2025-01
145 Audio/video, information technology and telecommunications equipment Electric strength Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.9.1 | PN-EN IEC 62368-1:2024-06/A11:2025-01
146 Audio/video, information technology and telecommunications equipment Verification of maximum operating temperatures for materials, components and systems and for touchable parts Ζ | PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2 | PN-EN IEC 62368-1:2024-06/A11:2025-01
147 Electrical appliances for household and similar use Verification of protection against access to live parts Ζ | PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3 | PN-EN IEC 60335-1:2024-04/A11:2024-10
148 Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Deviations Ζ | PN-EN 45544-1:2015-08 p. 5.4.3
149 Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Alarm thresholds Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.1
150 Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Heating time Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.4
151 Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Response time Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.5
152 Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Relaxation time Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.6.
153 Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Drift Ζ | PN-EN 45544-1:2015-08 p. 5.4.8
154 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm thresholds Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.2 | PN-EN 50291-1:2018-06/AC:2021-03
155 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Conditioning without power supply
Range (od -20 do +60) °C
Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.1.5 | PN-EN 50291-1:2018-06/AC:2021-03
156 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Signal outputs Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.3 | PN-EN 50291-1:2018-06/AC:2021-03
157 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm operating time Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.4 | PN-EN 50291-1:2018-06/AC:2021-03
158 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm response time during heating Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.5 | PN-EN 50291-1:2018-06/AC:2021-03
159 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of gas temperature on the device
Range (od -20 do +60) °C
Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.7 | PN-EN 50291-1:2018-06/AC:2021-03
160 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of gas humidity on the device
Range (20 - 95)% rh
Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.8 | PN-EN 50291-1:2018-06/AC:2021-03
161 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of gas flow rate on the device Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.9 | PN-EN 50291-1:2018-06/AC:2021-03
162 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of power supply variations on the device Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.10 | PN-EN 50291-1:2018-06/AC:2021-03
163 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Long-term stability Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.14 | PN-EN 50291-1:2018-06/AC:2021-03
164 Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm sound level
Range (80 - 110) dB (A)
Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.16 | PN-EN 50291-1:2018-06/AC:2021-03
165 Explosion-protected intrinsically safe equipment „i” Intrinsic safety testing using a spark test apparatus Ζ | PN-EN 60079-11:2012 p. 10.1
166 Explosion-protected intrinsically safe equipment „i” Testing of cells and batteries Ζ | PN-EN 60079-11:2012 p. 10.5
167 Explosion-protected intrinsically safe equipment „i” Measurements of geometric quantities (insulation clearances) Direct method Ζ | PN-EN 60079-11:2012 p. 6.3

Reference standards (286)

Dokumenty odniesienia
IEC 60502-2:2014 zał. F
IEC 60502-2:2014/AMD1:2024
ISO 10605:2023
ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9
ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9
ISO 11452-9:2021-10
ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10
ISO 20653:2013
ISO 7637-2:2011
ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10
ISO 7637-3:2007
PN-E-04160-11:1973
PN-E-04160-19:1992
PN-E-04160-24:1991
PN-E-04160-24:1991/Az1:1996
PN-E-04160-25:1989
PN-E-04160-25:1989/Az1:1998
PN-E-04160-56:1990
PN-E-04160-68:1988
PN-E-04160-69:1988
PN-E-04160-70:1983
PN-E-04160-73:1983
PN-E-04160-77:1973
PN-E-04160-78:1973
PN-EN 45544-1:2015-08 p. 5.4.3
PN-EN 45544-1:2015-08 p. 5.4.6.1
PN-EN 45544-1:2015-08 p. 5.4.6.4
PN-EN 45544-1:2015-08 p. 5.4.6.5
PN-EN 45544-1:2015-08 p. 5.4.6.6.
PN-EN 45544-1:2015-08 p. 5.4.8
PN-EN 50102:2001
PN-EN 50102:2001/AC:2011
PN-EN 50125-3:2003 p. 4.13
PN-EN 50125-3:2003/AC:2010
PN-EN 50155:2022-05 p. 13.4.10
PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6
PN-EN 50155:2022-05 p. 13.4.5
PN-EN 50155:2022-05 p. 13.4.7
PN-EN 50155:2022-05 p. 13.4.8
PN-EN 50289-1-2:2007
PN-EN 50289-1-3:2007
PN-EN 50289-1-4:2007
PN-EN 50289-1-5:2008
PN-EN 50289-3-2:2002
PN-EN 50291-1:2018-06 p.6.1.5
PN-EN 50291-1:2018-06 p.6.3.10
PN-EN 50291-1:2018-06 p.6.3.14
PN-EN 50291-1:2018-06 p.6.3.16
PN-EN 50291-1:2018-06 p.6.3.2
PN-EN 50291-1:2018-06 p.6.3.3
PN-EN 50291-1:2018-06 p.6.3.4
PN-EN 50291-1:2018-06 p.6.3.5
PN-EN 50291-1:2018-06 p.6.3.7
PN-EN 50291-1:2018-06 p.6.3.8
PN-EN 50291-1:2018-06 p.6.3.9
PN-EN 50291-1:2018-06/AC:2021-03
PN-EN 50395:2007
PN-EN 50395:2007/A1:2011
PN-EN 50396:2007
PN-EN 50396:2007/A1:2011
PN-EN 50604-1:2017-02, p. 8.3
PN-EN 50604-1:2017-02/A1:2022-05
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A11:2020-07
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-1:2014-09/AC:2020-11
PN-EN 55016-2-2:2011
PN-EN 55016-2-2:2011/Ap1:2013-06
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55022:2000 p. 9.6
PN-EN 55022:2000/A1:2003
PN-EN 55022:2000/A2:2004
PN-EN 55022:2000/AC:2005
PN-EN 55022:2011 p. 10
PN-EN 55022:2011 p. 9
PN-EN 55022:2011/Ap1:2013-07
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A11:2020-07
PN-EN 55032:2015-09/A1:2021-05
PN-EN 55032:2015-09/AC:2016-09
PN-EN 55032:2015-09/Ap1:2017-12
PN-EN 60068-2-1:2009
PN-EN 60068-2-27:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1
PN-EN 60068-2-31 p. 5.3
PN-EN 60068-2-39:2016-04
PN-EN 60068-2-39:2016-04 /Ap1:2019-04
PN-EN 60068-2-40:2002
PN-EN 60068-2-41:2002
PN-EN 60068-2-64:2008
PN-EN 60068-2-6:2008
PN-EN 60068-2-75:2015-01
PN-EN 60068-2-78:2007
PN-EN 60068-2-78:2013-11
PN-EN 60079-11:2012 p. 10.1
PN-EN 60079-11:2012 p. 10.5
PN-EN 60079-11:2012 p. 6.3
PN-EN 60228:2025-02
PN-EN 60243-1:2002
PN-EN 60243-1:2013-12
PN-EN 60255-21-1:1999
PN-EN 60255-21-2:2000
PN-EN 60255-26:2014-01 p. 7.1
PN-EN 60255-26:2014-01 p. 7.2.10
PN-EN 60255-26:2014-01 p. 7.2.11
PN-EN 60255-26:2014-01 p. 7.2.12
PN-EN 60255-26:2014-01 p. 7.2.3
PN-EN 60255-26:2014-01 p. 7.2.4
PN-EN 60255-26:2014-01 p. 7.2.5
PN-EN 60255-26:2014-01 p. 7.2.6
PN-EN 60255-26:2014-01 p. 7.2.7
PN-EN 60255-26:2014-01 p. 7.2.8
PN-EN 60255-26:2014-01/AC:2014-06
PN-EN 60332-1-2:2010
PN-EN 60332-1-2:2010/A11:2017-02
PN-EN 60332-1-2:2010/A12:2021-05
PN-EN 60332-1-2:2010/A1:2016-02
PN-EN 60332-2-2:2010
PN-EN 60529:2003
PN-EN 60529:2003/A2:2014-07
PN-EN 60529:2003/AC:2017-12
PN-EN 60529:2003/AC:2020-01
PN-EN 60695-10-2:2005
PN-EN 60695-10-2:2014-10
PN-EN 60695-11-10:2002
PN-EN 60695-11-10:2002/A1:2005
PN-EN 60695-11-10:2014-02
PN-EN 60695-11-10:2014/AC:2017-08
PN-EN 60695-11-20:2002
PN-EN 60695-11-20:2002/A1:2005
PN-EN 60695-11-20:2015-08
PN-EN 60695-11-20:2015-08 /AC:2017-01
PN-EN 60695-11-2:2017-11
PN-EN 60695-11-5:2017-08
PN-EN 60811-1-1:1999
PN-EN 60811-1-1:1999/A1:2002
PN-EN 60811-1-2:1999
PN-EN 60811-1-2:1999/A2:2002
PN-EN 60811-1-3:1999
PN-EN 60811-1-3:1999/A1:2002
PN-EN 60811-1-4:1999
PN-EN 60811-1-4:1999/A2:2002
PN-EN 60811-2-1:1999
PN-EN 60811-2-1:1999/A1:2002
PN-EN 60811-201:2012
PN-EN 60811-201:2012/A1:2018-02
PN-EN 60811-201:2012/A2:2024-03
PN-EN 60811-202:2012
PN-EN 60811-202:2012/A1:2018-02
PN-EN 60811-202:2012/A2:2024-03
PN-EN 60811-203:2012
PN-EN 60811-3-1:1999
PN-EN 60811-3-1:1999/A2:2002
PN-EN 60811-3-2:1999
PN-EN 60811-3-2:1999/A2:2005
PN-EN 60811-3-2:1999/Ap1:2006
PN-EN 60811-401:2012
PN-EN 60811-401:2012/A1:2018-02
PN-EN 60811-402:2012
PN-EN 60811-404:2012
PN-EN 60811-405:2012
PN-EN 60811-409:2012
PN-EN 60811-501:2012
PN-EN 60811-501:2012/A1:2019-01
PN-EN 60811-501:2012/A2:2024-03
PN-EN 60811-502:2012
PN-EN 60811-503:2012
PN-EN 60811-503:2012/A1:2024-03
PN-EN 60811-504:2012
PN-EN 60811-506:2012
PN-EN 60811-507:2012
PN-EN 60811-508:2012
PN-EN 60811-508:2012/A1:2018-02
PN-EN 60811-508:2012/A2:2024-03
PN-EN 60811-509:2012
PN-EN 60811-509:2012/A1:2018-02
PN-EN 60851-2:2010
PN-EN 60851-2:2010/A1:2015-09
PN-EN 60851-2:2010/A2:2019-12
PN-EN 60851-5:2008
PN-EN 60851-5:2008/A1:2011
PN-EN 60851-5:2008/A2:2020-06
PN-EN 60851-6:1998
PN-EN 60851-6:1998/A2:2005
PN-EN 60851-6:2013-03
PN-EN 61000-3-12:2012
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-3-3:2013-10/A2:2022-04
PN-EN 61000-3-3:2013-10/AC:2022-05
PN-EN 61000-4-10:2017-04
PN-EN 61000-4-12:2017-12
PN-EN 61000-4-13:2007
PN-EN 61000-4-13:2007/A1:2010
PN-EN 61000-4-13:2007/A2:2016-05
PN-EN 61000-4-15:2011
PN-EN 61000-4-16:2016-05
PN-EN 61000-4-17:2004
PN-EN 61000-4-17:2004/A1:2006
PN-EN 61000-4-17:2004/A2:2011
PN-EN 61000-4-29:2004
PN-EN 61000-4-2:2011
PN-EN 61000-4-34:2009
PN-EN 61000-4-34:2009/A1:2010
PN-EN 61000-4-39:2017-07
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-5:2014-10/A1:2018-01
PN-EN 61000-4-7:2007
PN-EN 61000-4-7:2007/A1:2011
PN-EN 61000-4-8:2010
PN-EN 61000-4-9:2016-11
PN-EN 61373:2011
PN-EN 61373:2011/AC:2017-11
PN-EN 62262:2003
PN-EN 62262:2003/A1:2022-06
PN-EN 62262:2003/Ap1:2022-01
PN-EN IEC 55014-1:2021-08
PN-EN IEC 55015:2019-11
PN-EN IEC 55015:2019-11/A11:2020-07
PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8
PN-EN IEC 60068-2-13:2021-11
PN-EN IEC 60068-2-14:2024-04
PN-EN IEC 60335-1:2024-04 /A11:2024-10
PN-EN IEC 60335-1:2024-04 p. 21.1
PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3
PN-EN IEC 60335-1:2024-04/A11:2024-10
PN-EN IEC 60598-1:2025-04 /A11:2025-08
PN-EN IEC 60598-1:2025-04 p. 7.13.1
PN-EN IEC 60598-1:2025-04 p. 7.13.4
PN-EN IEC 60598-1:2025-04 p. 7.20.1
PN-EN IEC 60598-1:2025-04/A11:2025-08
PN-EN IEC 60851-3:2024-05 p. 4
PN-EN IEC 60851-3:2024-05 p. 6.2
PN-EN IEC 61000-3-11:2020-01
PN-EN IEC 61000-3-2:2019-04
PN-EN IEC 61000-3-2:2019-04/A1:2021-08
PN-EN IEC 61000-4-11:2020-11
PN-EN IEC 61000-4-11:2020-11/AC:2020-12
PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3
PN-EN IEC 61000-4-18:2019-08
PN-EN IEC 61000-4-18:2019-08/AC:2019-12
PN-EN IEC 61000-4-3:2021-06,
PN-EN IEC 61000-4-6:2024-03
PN-EN IEC 62368-1:2024-06 p. 5.4.8
PN-EN IEC 62368-1:2024-06 p. 5.4.9.1
PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3
PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2
PN-EN IEC 62368-1:2024-06/A11:2025-01
PN-EN ISO 4589-2:2006
PN-EN ISO 4589-2:2006/A1:2006
PN-EN ISO 527-1:2020-01
PN-EN ISO 527-2:2012
PN-EN ISO 527-2:2012/Ap1:2013-09
PN-EN ISO 527-3:1998
PN-EN ISO 6892-1:2010
PN-EN ISO 6892-1:2010/Ap1:2015-02
PN-EN ISO 9773:2025-03
PN-G 50003:2003
PN-G 50006:1997
PN-G-42010:1997
PN-G-50003:2003
PN-G-50006:1997
PN-HD 605-S3:2020-05
PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6)
PN-HD 605-S3:2020-05 p. 2.4.4.1
PN-ISO 37:2007
PN-ISO 37:2007/AC1:2008
Ζ
Ζ NO-06-A500:2012 p. 3.14
Ζ NO-06-A500:2012 p. 3.17
Ζ NO-06-A500:2012 p. 3.2
Ζ NO-06-A500:2012 p. 3.9
Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)
Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)
Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)
Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)
Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)
Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)