{"lab":{"_id":"69ad52a3de79e566650fb189","accr_number":"AB 261","country":"PL","accr_body":"PCA","address":"INTELIGENCJI I CYBERBEZPIECZEŃSTWA, CENTRUM BADAŃ I CERTYFIKACJI, ZESPÓŁ LABORATORIÓW BADAWCZYCH, ul. Leopolda 31","categories":["electronics","construction","automotive","materials"],"city":"Katowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":167,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT SZTUCZNEJ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_261.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - instytut sztucznej inteligencji i cyberbezpieczeństwa, centrum badań i certyfikacji, zespół laboratoriów badawczych, ul. leopolda 31 pharma electronics other materials automotive water environment construction food metrology","status":"active","updated_at":"2026-03-08T14:51:07.007Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:07.007Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20261,podmiot.html","fields_of_testing":[{"codes":"E/6; E/13; E/21; E53; E/54","pl":"Badania elektryczne i elektroniczne - wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, wyrobów z tworzyw sztucznych i gumy, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electrical, products and equipment, machinery and devices, plastic and rubber products, telecommunication products and equipment, electronic products and equipment"},{"codes":"F/6; F/13; F/14; F/15; F/25; F/26; F/50; F53; F/54","pl":"Badania kompatybilności elektromagnetycznej - wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, wyposażenia medycznego, wyposażenia wojskowego, zabawek, pojazdów, sprzętu sportowego i rekreacyjnego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility tests of electrical, products and equipment, machinery and devices, medical equipment, military equipment, toys, vehicles, sports and leisure equipment, telecommunication products and equipment, electronic products and equipment"},{"codes":"G/6; G/13; G/14, G/15, G/21, G/25, G/26; G/50; G53; G54","pl":"Badania dotyczące inżynierii środowiska - wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, wyposażenia medycznego, wyposażenia wojskowego, wyrobów z tworzyw sztucznych i gumy, zabawek, pojazdów, sprzętu sportowego i rekreacyjnego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests concerning environmental engineering of electrical products and equipment, machinery and devices, medical equipment, military equipment, plastic and rubber products, toys, vehicles, sports and leisure equipment, telecommunication products and equipment, electronic products and equipment,"}],"issue":{"no":"27","date":"17.02.2026"},"parse_date":"2026-07-20T07:09:32.328Z","parse_source":"script-pdfplumber","map_coord":[50.272342,19.045847],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":81,"electronics":68,"construction":12,"automotive":8,"materials":5,"water":1,"petro":1},"category_scores":{"other":37.28,"electronics":26.27,"construction":0.82,"automotive":0.36,"materials":0.14,"water":0.01,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9acf1c10c8ce825a6d0","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"Poziom probierczy","range":"(0,2 - 30) kV"}],"parameters_en":[{"name":"Test level","range":"(0,2 - 30) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV","reference":"Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-2:2011","PN-EN 60255-26:2014-01 p. 7.2.3","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na wyładowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na wyladowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrostatic discharge Test level Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0,2 - 30) kV"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 静电放电抗扰度 试验等级 Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"静电放电抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6d1","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[{"name":"Częstotliwość","range":"(0,08 - 6) GHz"},{"name":"Badanie w komorze semibezodbiciowej SAC"}],"parameters_en":[{"name":"Frequency","range":"(0,08 - 6) GHz"},{"name":"Testing in a semi-anechoic chamber SAC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,08 - 6) GHz\nBadanie w komorze semibezodbiciowej SAC","reference":"Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-3:2021-06,","PN-EN 60255-26:2014-01 p. 7.2.4","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,08 - 6) GHz\nBadanie w komorze semibezodbiciowej SAC Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej\nZakres:\nCzestotliwosc (0,08 - 6) GHz\nBadanie w komorze semibezodbiciowej SAC Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to radiated radio-frequency electromagnetic field Frequency Testing in a semi-anechoic chamber SAC Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,08 - 6) GHz"},{"name":"Badanie w komorze semibezodbiciowej SAC"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 射频辐射电磁场抗扰度 频率 Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"射频辐射电磁场抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6d2","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","methodology_en":"Immunity to electrical fast transients/bursts","parameters":[{"name":"Poziom probierczy","range":"(0,25 - 5,5) kV"},{"name":"przy częstotliwości powtarzania 5 kHz i 100 kHz"}],"parameters_en":[{"name":"Test level","range":"(0,25 - 5,5) kV"},{"name":"at a repetition frequency of 5 kHz and 100 kHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres:\nPoziom probierczy (0,25 - 5,5) kV\nprzy częstotliwości powtarzania 5 kHz i 100 kHz","reference":"Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-4:2013-05","PN-EN 60255-26:2014-01 p. 7.2.5","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres:\nPoziom probierczy (0,25 - 5,5) kV\nprzy częstotliwości powtarzania 5 kHz i 100 kHz Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na serie szybkich elektrycznych stanow przejsciowych\nZakres:\nPoziom probierczy (0,25 - 5,5) kV\nprzy czestotliwosci powtarzania 5 kHz i 100 kHz Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrical fast transients/bursts Test level at a repetition frequency of 5 kHz and 100 kHz Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0,25 - 5,5) kV"},{"name":"przy częstotliwości powtarzania 5 kHz i 100 kHz"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 电快速瞬变脉冲群抗扰度 试验等级 Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6d3","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na udary","methodology_en":"Immunity to surges","parameters":[{"name":"Poziom probierczy","range":"(0,5 - 6) kV"}],"parameters_en":[{"name":"Test level","range":"(0,5 - 6) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary\nPoziom probierczy (0,5 - 6) kV","reference":"Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-5:2014-10","PN-EN 61000-4-5:2014-10/A1:2018-01","PN-EN 60255-26:2014-01 p. 7.2.7","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na udary\nPoziom probierczy (0,5 - 6) kV Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na udary\nPoziom probierczy (0,5 - 6) kV Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to surges Test level Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0,5 - 6) kV"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 浪涌抗扰度 试验等级 Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"浪涌抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6d4","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Częstotliwość","range":"(0,01 - 400) MHz"},{"name":"Poziom probierczy","range":"(0,1 - 20) V"}],"parameters_en":[{"name":"Frequency","range":"(0,01 - 400) MHz"},{"name":"Test level","range":"(0,1 - 20) V"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,01 - 400) MHz\nPoziom probierczy (0,1 - 20) V","reference":"Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-6:2024-03","PN-EN 60255-26:2014-01 p. 7.2.8","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,01 - 400) MHz\nPoziom probierczy (0,1 - 20) V Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej\nZakres:\nCzestotliwosc (0,01 - 400) MHz\nPoziom probierczy (0,1 - 20) V Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to conducted disturbances induced by radio-frequency fields Frequency Test level Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,01 - 400) MHz"},{"name":"试验等级","range":"(0,1 - 20) V"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 射频场感应的传导骚扰抗扰度 频率 试验等级 Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6d5","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[{"name":"Poziom probierczy","range":"(1 - 300) A/m"}],"parameters_en":[{"name":"Test level","range":"(1 - 300) A/m"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nPoziom probierczy (1 - 300) A/m","reference":"Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-8:2010","PN-EN 60255-26:2014-01 p. 7.2.10","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nPoziom probierczy (1 - 300) A/m Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nPoziom probierczy (1 - 300) A/m Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to power-frequency magnetic field Test level Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(1 - 300) A/m"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 工频磁场抗扰度 试验等级 Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"工频磁场抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6d6","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m","methodology_en":"Immunity to pulse magnetic field, Test level: (100 - 1000) A/m","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m","reference":"Ζ | PN-EN 61000-4-9:2016-11","norm_bases":["Ζ","PN-EN 61000-4-9:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11","categories":["electronics"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to pulse magnetic field, Test level: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） Ζ | PN-EN 61000-4-9:2016-11","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a6d7","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia, Poziom probierczy: 0% UT, 40% UT, 70% UT, 80% UT","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations, Test level: 0% UT, 40% UT, 70% UT, 80% UT","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia, Poziom probierczy: 0% UT, 40% UT, 70% UT, 80% UT","reference":"Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-11:2020-11","PN-EN IEC 61000-4-11:2020-11/AC:2020-12","PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3","PN-EN 60255-26:2014-01 p. 7.2.11","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia, Poziom probierczy: 0% UT, 40% UT, 70% UT, 80% UT Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia, Poziom probierczy: 0% UT, 40% UT, 70% UT, 80% UT Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wylaczeniem p. 5.3 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations, Test level: 0% UT, 40% UT, 70% UT, 80% UT Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a6d8","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na tłumione przebiegi sinusoidalne","methodology_en":"Immunity to damped oscillatory waves","parameters":[{"name":"Poziom probierczy","range":"(0,25 - 6) kV"}],"parameters_en":[{"name":"Test level","range":"(0,25 - 6) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na tłumione przebiegi sinusoidalne\nPoziom probierczy (0,25 - 6) kV","reference":"Ζ | PN-EN 61000-4-12:2017-12","norm_bases":["Ζ","PN-EN 61000-4-12:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na tłumione przebiegi sinusoidalne\nPoziom probierczy (0,25 - 6) kV Ζ | PN-EN 61000-4-12:2017-12 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na tlumione przebiegi sinusoidalne\nPoziom probierczy (0,25 - 6) kV Ζ | PN-EN 61000-4-12:2017-12","categories":["electronics"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory waves Test level Ζ | PN-EN 61000-4-12:2017-12","parameters_zh":[{"name":"试验等级","range":"(0,25 - 6) kV"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 试验等级 Ζ | PN-EN 61000-4-12:2017-12","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a6d9","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia występujące w przyłączu zasilającym prądem stałym, Poziom probierczy: (0% - 120%) UT","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations occurring at the DC power port, Test level: (0% - 120%) UT","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia występujące w przyłączu zasilającym prądem stałym, Poziom probierczy: (0% - 120%) UT","reference":"Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-29:2004","PN-EN 60255-26:2014-01 p. 7.2.11","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia występujące w przyłączu zasilającym prądem stałym, Poziom probierczy: (0% - 120%) UT Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia wystepujace w przylaczu zasilajacym pradem stalym, Poziom probierczy: (0% - 120%) UT Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations occurring at the DC power port, Test level: (0% - 120%) UT Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a6da","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na pola radiowe w bliskiej odległości","methodology_en":"Immunity to radio fields in close proximity","parameters":[{"name":"Częstotliwość","range":"(0,009 - 26) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 26) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pola radiowe w bliskiej odległości\nCzęstotliwość (0,009 - 26) MHz","reference":"Ζ | PN-EN 61000-4-39:2017-07","norm_bases":["Ζ","PN-EN 61000-4-39:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na pola radiowe w bliskiej odległości\nCzęstotliwość (0,009 - 26) MHz Ζ | PN-EN 61000-4-39:2017-07 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na pola radiowe w bliskiej odleglosci\nCzestotliwosc (0,009 - 26) MHz Ζ | PN-EN 61000-4-39:2017-07","categories":["electronics"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to radio fields in close proximity Frequency Ζ | PN-EN 61000-4-39:2017-07","parameters_zh":[{"name":"频率","range":"(0,009 - 26) MHz"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 近场射频场抗扰度 频率 Ζ | PN-EN 61000-4-39:2017-07","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"近场射频场抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6db","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","norm_bases":["Ζ","PN-EN 55016-2-1:2014-09","PN-EN 55016-2-1:2014-09/A1:2017-12","PN-EN 55016-2-1:2014-09/AC:2020-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 Urzadzenia elektryczne i elektroniczne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","categories":["electronics"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"电气与电子设备 电源端子骚扰电压 频率 Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","test_object_zh":"电气与电子设备","methodology_zh":"电源端子骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a6dc","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"},{"name":"oraz w miejscu instalacji / IN SITU"},{"name":"Częstotliwość","range":"(0,03 - 1) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"},{"name":"and at the installation site / IN SITU"},{"name":"Frequency","range":"(0,03 - 1) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 18) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz","reference":"Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","norm_bases":["Ζ","PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 18) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 Urzadzenia elektryczne i elektroniczne Natezenie pola elektromagnetycznego\nZakres:\nCzestotliwosc (0,0001 - 18) GHz\noraz w miejscu instalacji / IN SITU\nCzestotliwosc (0,03 - 1) GHz Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","categories":["electronics"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Electromagnetic field strength Frequency and at the installation site / IN SITU Frequency Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"},{"name":"以及安装现场 / IN SITU"},{"name":"频率","range":"(0,03 - 1) GHz"}],"search_zh":"电气与电子设备 电磁场强度 频率 以及安装现场 / IN SITU 频率 Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","test_object_zh":"电气与电子设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a6dd","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej","test_object_en":"Industrial, scientific and medical (ISM) radio-frequency equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["Ζ","PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Przemyslowe, medyczne i naukowe (PMN) urzadzenia o czestotliwosci radiowej Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial, scientific and medical (ISM) radio-frequency equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"工业、医疗与科学（ISM）射频设备 电源端子骚扰电压 频率 Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","methodology_zh":"电源端子骚扰电压","test_object_zh":"工业、医疗与科学（ISM）射频设备"},{"_id":"6a5dc9acf1c10c8ce825a6de","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej","test_object_en":"Industrial, scientific and medical (ISM) radio-frequency equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"},{"name":"oraz w miejscu instalacji / IN SITU"},{"name":"Częstotliwość","range":"(0,03 - 1) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"},{"name":"and at the installation site / IN SITU"},{"name":"Frequency","range":"(0,03 - 1) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 18) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz","reference":"Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["Ζ","PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 18) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Przemyslowe, medyczne i naukowe (PMN) urzadzenia o czestotliwosci radiowej Natezenie pola elektromagnetycznego\nZakres:\nCzestotliwosc (0,0001 - 18) GHz\noraz w miejscu instalacji / IN SITU\nCzestotliwosc (0,03 - 1) GHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial, scientific and medical (ISM) radio-frequency equipment Electromagnetic field strength Frequency and at the installation site / IN SITU Frequency Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"},{"name":"以及安装现场 / IN SITU"},{"name":"频率","range":"(0,03 - 1) GHz"}],"search_zh":"工业、医疗与科学（ISM）射频设备 电磁场强度 频率 以及安装现场 / IN SITU 频率 Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","methodology_zh":"电磁场强度","test_object_zh":"工业、医疗与科学（ISM）射频设备"},{"_id":"6a5dc9acf1c10c8ce825a6df","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","norm_bases":["Ζ","PN-EN 55022:2011 p. 9","PN-EN 55022:2011/Ap1:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07 Urzadzenia informatyczne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"信息技术设备 电源端子骚扰电压 频率 Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","test_object_zh":"信息技术设备","methodology_zh":"电源端子骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a6e0","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Napięcie zaburzeń na przyłączach telekomunikacyjnych","methodology_en":"Disturbance voltage at telecommunication ports","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55022:2000 p. 9.6 | PN-EN 55022:2000/A2:2004 | PN-EN 55022:2000/A1:2003 | PN-EN 55022:2000/AC:2005","norm_bases":["Ζ","PN-EN 55022:2000 p. 9.6","PN-EN 55022:2000/A2:2004","PN-EN 55022:2000/A1:2003","PN-EN 55022:2000/AC:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55022:2000 p. 9.6 | PN-EN 55022:2000/A2:2004 | PN-EN 55022:2000/A1:2003 | PN-EN 55022:2000/AC:2005 Urzadzenia informatyczne Napiecie zaburzen na przylaczach telekomunikacyjnych\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55022:2000 p. 9.6 | PN-EN 55022:2000/A2:2004 | PN-EN 55022:2000/A1:2003 | PN-EN 55022:2000/AC:2005","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment Disturbance voltage at telecommunication ports Frequency Ζ | PN-EN 55022:2000 p. 9.6 | PN-EN 55022:2000/A2:2004 | PN-EN 55022:2000/A1:2003 | PN-EN 55022:2000/AC:2005","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"信息技术设备 电信端口上的骚扰电压 频率 Ζ | PN-EN 55022:2000 p. 9.6 | PN-EN 55022:2000/A2:2004 | PN-EN 55022:2000/A1:2003 | PN-EN 55022:2000/AC:2005","test_object_zh":"信息技术设备","methodology_zh":"电信端口上的骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a6e1","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz","reference":"Ζ | PN-EN 55022:2011 p. 10 | PN-EN 55022:2011/Ap1:2013-07","norm_bases":["Ζ","PN-EN 55022:2011 p. 10","PN-EN 55022:2011/Ap1:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz Ζ | PN-EN 55022:2011 p. 10 | PN-EN 55022:2011/Ap1:2013-07 Urzadzenia informatyczne Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 18) GHz Ζ | PN-EN 55022:2011 p. 10 | PN-EN 55022:2011/Ap1:2013-07","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment Electromagnetic field strength Frequency Ζ | PN-EN 55022:2011 p. 10 | PN-EN 55022:2011/Ap1:2013-07","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"}],"search_zh":"信息技术设备 电磁场强度 频率 Ζ | PN-EN 55022:2011 p. 10 | PN-EN 55022:2011/Ap1:2013-07","test_object_zh":"信息技术设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a6e2","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["Ζ","PN-EN 55032:2015-09","PN-EN 55032:2015-09/AC:2016-09","PN-EN 55032:2015-09/Ap1:2017-12","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"多媒体设备 电源端子骚扰电压 频率 Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","methodology_zh":"电源端子骚扰电压","test_object_zh":"多媒体设备"},{"_id":"6a5dc9acf1c10c8ce825a6e3","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz","reference":"Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["Ζ","PN-EN 55032:2015-09","PN-EN 55032:2015-09/AC:2016-09","PN-EN 55032:2015-09/Ap1:2017-12","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 18) GHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Electromagnetic field strength Frequency Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"}],"search_zh":"多媒体设备 电磁场强度 频率 Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a6e4","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe","test_object_en":"Measuring relays and protection equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 60255-26:2014-01 p. 7.1","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06 Przekazniki pomiarowe i urzadzenia zabezpieczeniowe Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measuring relays and protection equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"量度继电器与保护装置 电源端子骚扰电压 频率 Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","methodology_zh":"电源端子骚扰电压","test_object_zh":"量度继电器与保护装置"},{"_id":"6a5dc9acf1c10c8ce825a6e5","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe","test_object_en":"Measuring relays and protection equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz","reference":"Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 60255-26:2014-01 p. 7.1","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06 Przekazniki pomiarowe i urzadzenia zabezpieczeniowe Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 18) GHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measuring relays and protection equipment Electromagnetic field strength Frequency Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"}],"search_zh":"量度继电器与保护装置 电磁场强度 频率 Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","methodology_zh":"电磁场强度","test_object_zh":"量度继电器与保护装置"},{"_id":"6a5dc9acf1c10c8ce825a6e6","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Disturbance voltage at the mains terminals Frequency Ζ | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"家用器具、电动工具及类似设备 电源端子骚扰电压 频率 Ζ | PN-EN IEC 55014-1:2021-08","methodology_zh":"电源端子骚扰电压","test_object_zh":"家用器具、电动工具及类似设备"},{"_id":"6a5dc9acf1c10c8ce825a6e7","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Napięcie zaburzeń na przyłączach telekomunikacyjnych","methodology_en":"Disturbance voltage at telecommunication ports","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Napiecie zaburzen na przylaczach telekomunikacyjnych\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Disturbance voltage at telecommunication ports Frequency Ζ | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"家用器具、电动工具及类似设备 电信端口上的骚扰电压 频率 Ζ | PN-EN IEC 55014-1:2021-08","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"电信端口上的骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a6e8","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz","reference":"Ζ | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz Ζ | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 18) GHz Ζ | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Electromagnetic field strength Frequency Ζ | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"}],"search_zh":"家用器具、电动工具及类似设备 电磁场强度 频率 Ζ | PN-EN IEC 55014-1:2021-08","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a6e9","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","test_object_en":"Electrical lighting and similar equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","norm_bases":["Ζ","PN-EN IEC 55015:2019-11","PN-EN IEC 55015:2019-11/A11:2020-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical lighting and similar equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"电气照明设备及类似设备 电源端子骚扰电压 频率 Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","test_object_zh":"电气照明设备及类似设备","methodology_zh":"电源端子骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a6ea","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","test_object_en":"Electrical lighting and similar equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz","reference":"Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","norm_bases":["Ζ","PN-EN IEC 55015:2019-11","PN-EN IEC 55015:2019-11/A11:2020-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 18) GHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 18) GHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical lighting and similar equipment Electromagnetic field strength Frequency Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"}],"search_zh":"电气照明设备及类似设备 电磁场强度 频率 Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","test_object_zh":"电气照明设备及类似设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a6eb","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Harmoniczne i interharmoniczne prądu","methodology_en":"Current harmonics and interharmonics","parameters":[{"name":"Zakres","range":"(2 - 40) harmonicznej"}],"parameters_en":[{"name":"Range","range":"(2 - 40) harmonicznej"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Harmoniczne i interharmoniczne prądu\nZakres (2 - 40) harmonicznej","reference":"Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","norm_bases":["Ζ","PN-EN 61000-4-7:2007","PN-EN 61000-4-7:2007/A1:2011","PN-EN IEC 61000-3-2:2019-04","PN-EN IEC 61000-3-2:2019-04/A1:2021-08","PN-EN 61000-3-12:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Harmoniczne i interharmoniczne prądu\nZakres (2 - 40) harmonicznej Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012 Urzadzenia elektryczne i elektroniczne Harmoniczne i interharmoniczne pradu\nZakres (2 - 40) harmonicznej Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","categories":["electronics"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Current harmonics and interharmonics Range Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","parameters_zh":[{"name":"范围","range":"(2 - 40) harmonicznej"}],"search_zh":"电气与电子设备 范围 Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","test_object_zh":"电气与电子设备"},{"_id":"6a5dc9acf1c10c8ce825a6ec","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Wahania napięcia i migotania światła","methodology_en":"Voltage fluctuations and flicker","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wahania napięcia i migotania światła","reference":"Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","norm_bases":["Ζ","PN-EN 61000-4-15:2011","PN-EN 61000-3-3:2013-10","PN-EN 61000-3-3:2013-10/A1:2019-10","PN-EN 61000-3-3:2013-10/A2:2022-04","PN-EN 61000-3-3:2013-10/AC:2022-05","PN-EN IEC 61000-3-11:2020-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Wahania napięcia i migotania światła Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01 Urzadzenia elektryczne i elektroniczne Wahania napiecia i migotania swiatla Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","categories":["electronics"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Voltage fluctuations and flicker Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","search_zh":"电气与电子设备 电压波动与闪烁 Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","test_object_zh":"电气与电子设备","methodology_zh":"电压波动与闪烁"},{"_id":"6a5dc9acf1c10c8ce825a6ed","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Odporności na zaburzenia impulsowe występujące w pokładowych instalacjach elektrycznych pojazdów (impulsy: 1, 2a, 2b, 3a, 3b i 4)","methodology_en":"Immunity to transient disturbances occurring in vehicle on-board electrical systems (pulses: 1, 2a, 2b, 3a, 3b and 4)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporności na zaburzenia impulsowe występujące w pokładowych instalacjach elektrycznych pojazdów (impulsy: 1, 2a, 2b, 3a, 3b i 4)","reference":"Ζ | ISO 7637-2:2011 | ISO 7637-3:2007 | ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10","norm_bases":["Ζ","ISO 7637-2:2011","ISO 7637-3:2007","ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Odporności na zaburzenia impulsowe występujące w pokładowych instalacjach elektrycznych pojazdów (impulsy: 1, 2a, 2b, 3a, 3b i 4) Ζ | ISO 7637-2:2011 | ISO 7637-3:2007 | ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Odpornosci na zaburzenia impulsowe wystepujace w pokladowych instalacjach elektrycznych pojazdow (impulsy: 1, 2a, 2b, 3a, 3b i 4) Ζ | ISO 7637-2:2011 | ISO 7637-3:2007 | ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zal. 10","categories":["automotive","electronics"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Immunity to transient disturbances occurring in vehicle on-board electrical systems (pulses: 1, 2a, 2b, 3a, 3b and 4) Ζ | ISO 7637-2:2011 | ISO 7637-3:2007 | ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10","search_zh":"汽车行业用电气与电子组件 Ζ | ISO 7637-2:2011 | ISO 7637-3:2007 | ISO 16750-2:2010 Regulamin EKG ONZ nr 10 wer. 3 zał. 10","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6ee","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[{"name":"Częstotliwość","range":"(0,2 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,2 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nCzęstotliwość (0,2 - 6) GHz","reference":"Ζ | ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9","norm_bases":["Ζ","ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nCzęstotliwość (0,2 - 6) GHz Ζ | ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej\nCzestotliwosc (0,2 - 6) GHz Ζ | ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zal. 9","categories":["automotive","electronics"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Immunity to radiated radio-frequency electromagnetic field Frequency Ζ | ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9","parameters_zh":[{"name":"频率","range":"(0,2 - 6) GHz"}],"search_zh":"汽车行业用电气与电子组件 射频辐射电磁场抗扰度 频率 Ζ | ISO 11452-2:2019-01 Regulamin EKG ONZ nr 10 wer. 3 zał. 9","methodology_zh":"射频辐射电磁场抗扰度","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6ef","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej (BCI)","methodology_en":"Immunity to conducted disturbances, induced by radio-frequency fields (BCI)","parameters":[{"name":"Częstotliwość","range":"(0,1 - 400) MHz"},{"name":"Poziom probierczy","range":"(1 - 109) dB (μA)"}],"parameters_en":[{"name":"Frequency","range":"(0,1 - 400) MHz"},{"name":"Test level","range":"(1 - 109) dB (μA)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej (BCI)\nZakres:\nCzęstotliwość (0,1 - 400) MHz\nPoziom probierczy (1 - 109) dB (μA)","reference":"Ζ | ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9","norm_bases":["Ζ","ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej (BCI)\nZakres:\nCzęstotliwość (0,1 - 400) MHz\nPoziom probierczy (1 - 109) dB (μA) Ζ | ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej (BCI)\nZakres:\nCzestotliwosc (0,1 - 400) MHz\nPoziom probierczy (1 - 109) dB (μA) Ζ | ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zal. 9","categories":["automotive","electronics"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Immunity to conducted disturbances, induced by radio-frequency fields (BCI) Frequency Test level Ζ | ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9","parameters_zh":[{"name":"频率","range":"(0,1 - 400) MHz"},{"name":"试验等级","range":"(1 - 109) dB (μA)"}],"search_zh":"汽车行业用电气与电子组件 频率 试验等级 Ζ | ISO 11452-4:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 9","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6f0","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Odporność na wąskopasmowe zaburzenia radioelektryczne od nadajników przenośnych","methodology_en":"Immunity to narrowband radio disturbances from portable transmitters","parameters":[{"name":"Częstotliwość","range":"(0,026 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,026 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wąskopasmowe zaburzenia radioelektryczne od nadajników przenośnych\nCzęstotliwość (0,026 - 6) GHz","reference":"Ζ | ISO 11452-9:2021-10","norm_bases":["Ζ","ISO 11452-9:2021-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Odporność na wąskopasmowe zaburzenia radioelektryczne od nadajników przenośnych\nCzęstotliwość (0,026 - 6) GHz Ζ | ISO 11452-9:2021-10 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Odpornosc na waskopasmowe zaburzenia radioelektryczne od nadajnikow przenosnych\nCzestotliwosc (0,026 - 6) GHz Ζ | ISO 11452-9:2021-10","categories":["automotive","electronics"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Immunity to narrowband radio disturbances from portable transmitters Frequency Ζ | ISO 11452-9:2021-10","parameters_zh":[{"name":"频率","range":"(0,026 - 6) GHz"}],"search_zh":"汽车行业用电气与电子组件 频率 Ζ | ISO 11452-9:2021-10","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6f1","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"Poziom probierczy","range":"(0,2 - 30) kV"}],"parameters_en":[{"name":"Test level","range":"(0,2 - 30) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV","reference":"Ζ | ISO 10605:2023","norm_bases":["Ζ","ISO 10605:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Odporność na wyładowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV Ζ | ISO 10605:2023 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Odpornosc na wyladowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV Ζ | ISO 10605:2023","categories":["automotive","electronics"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Immunity to electrostatic discharge Test level Ζ | ISO 10605:2023","parameters_zh":[{"name":"试验等级","range":"(0,2 - 30) kV"}],"search_zh":"汽车行业用电气与电子组件 静电放电抗扰度 试验等级 Ζ | ISO 10605:2023","methodology_zh":"静电放电抗扰度","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6f2","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,1 - 108) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,1 - 108) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,1 - 108) MHz","reference":"Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8","norm_bases":["Ζ","PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,1 - 108) MHz Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,1 - 108) MHz Ζ | PN-EN IEC 55025:2022-09 z wylaczeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zal. 7 i zal. 8","categories":["automotive","electronics"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Disturbance voltage at the mains terminals Frequency Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8","parameters_zh":[{"name":"频率","range":"(0,1 - 108) MHz"}],"search_zh":"汽车行业用电气与电子组件 电源端子骚扰电压 频率 Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8","methodology_zh":"电源端子骚扰电压","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6f3","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Natężenie pola elektromagnetycznego (w odległości 1 m)","methodology_en":"Electromagnetic field strength (at a distance of 1 m)","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego (w odległości 1 m)\nCzęstotliwość (0,0001 - 18) GHz","reference":"Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8","norm_bases":["Ζ","PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Natężenie pola elektromagnetycznego (w odległości 1 m)\nCzęstotliwość (0,0001 - 18) GHz Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Natezenie pola elektromagnetycznego (w odleglosci 1 m)\nCzestotliwosc (0,0001 - 18) GHz Ζ | PN-EN IEC 55025:2022-09 z wylaczeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zal. 7 i zal. 8","categories":["automotive","electronics"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Electromagnetic field strength (at a distance of 1 m) Frequency Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8","parameters_zh":[{"name":"频率","range":"(0,0001 - 18) GHz"}],"search_zh":"汽车行业用电气与电子组件 频率 Ζ | PN-EN IEC 55025:2022-09 z wyłączeniem p. 6.6 Regulamin EKG ONZ nr 10 wer. 3 zał. 7 i zał. 8","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6f4","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive","test_object_en":"Electrical and electronic components used in the Automotive industry","methodology":"Napięcie zaburzeń na zaciskach zasilania (stany przejściowe w pokładowych instalacjach elektrycznych pojazdów o napięciu zasilania 12 V i 24 V)","methodology_en":"Disturbance voltage at the supply terminals (transients in on-board vehicle electrical systems with 12 V and 24 V supply voltage)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania (stany przejściowe w pokładowych instalacjach elektrycznych pojazdów o napięciu zasilania 12 V i 24 V)","reference":"Ζ | ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10","norm_bases":["Ζ","ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podzespoły elektryczne i elektroniczne stosowane w branży Automotive Napięcie zaburzeń na zaciskach zasilania (stany przejściowe w pokładowych instalacjach elektrycznych pojazdów o napięciu zasilania 12 V i 24 V) Ζ | ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10 Podzespoly elektryczne i elektroniczne stosowane w branzy Automotive Napiecie zaburzen na zaciskach zasilania (stany przejsciowe w pokladowych instalacjach elektrycznych pojazdow o napieciu zasilania 12 V i 24 V) Ζ | ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zal. 10","categories":["automotive","electronics"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic components used in the Automotive industry Disturbance voltage at the supply terminals (transients in on-board vehicle electrical systems with 12 V and 24 V supply voltage) Ζ | ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10","search_zh":"汽车行业用电气与电子组件 Ζ | ISO 7637-2:2011 Regulamin EKG ONZ nr 10 wer. 3 zał. 10","test_object_zh":"汽车行业用电气与电子组件"},{"_id":"6a5dc9acf1c10c8ce825a6f5","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP","test_object_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland","methodology":"Odporność na narażenia promieniowane, pole elektryczne","methodology_en":"Immunity to radiated disturbances, electric field","parameters":[{"name":"Częstotliwość","range":"(0,08 - 1) GHz"},{"name":"Poziom probierczy","range":"(1 - 20) V/m"},{"name":"Częstotliwość","range":"(1 - 4) GHz"},{"name":"Poziom probierczy","range":"(1 - 50) V/m"}],"parameters_en":[{"name":"Frequency","range":"(0,08 - 1) GHz"},{"name":"Test level","range":"(1 - 20) V/m"},{"name":"Frequency","range":"(1 - 4) GHz"},{"name":"Test level","range":"(1 - 50) V/m"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia promieniowane, pole elektryczne\nZakres:\nCzęstotliwość (0,08 - 1) GHz\nPoziom probierczy (1 - 20) V/m\nCzęstotliwość (1 - 4) GHz\nPoziom probierczy (1 - 50) V/m","reference":"Ζ NO-06-A500:2012 p. 3.17","norm_bases":["Ζ NO-06-A500:2012 p. 3.17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP Odporność na narażenia promieniowane, pole elektryczne\nZakres:\nCzęstotliwość (0,08 - 1) GHz\nPoziom probierczy (1 - 20) V/m\nCzęstotliwość (1 - 4) GHz\nPoziom probierczy (1 - 50) V/m Ζ NO-06-A500:2012 p. 3.17 Urzadzenia lub zestawy urzadzen elektrycznych, elektromechanicznych i elektronicznych przeznaczone do uzytkowania w Silach, Zbrojnych RP Odpornosc na narazenia promieniowane, pole elektryczne\nZakres:\nCzestotliwosc (0,08 - 1) GHz\nPoziom probierczy (1 - 20) V/m\nCzestotliwosc (1 - 4) GHz\nPoziom probierczy (1 - 50) V/m Ζ NO-06-A500:2012 p. 3.17","categories":["electronics"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Immunity to radiated disturbances, electric field Frequency Test level Frequency Test level Ζ NO-06-A500:2012 p. 3.17","parameters_zh":[{"name":"频率","range":"(0,08 - 1) GHz"},{"name":"试验等级","range":"(1 - 20) V/m"},{"name":"频率","range":"(1 - 4) GHz"},{"name":"试验等级","range":"(1 - 50) V/m"}],"search_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组 频率 试验等级 频率 试验等级 Ζ NO-06-A500:2012 p. 3.17","test_object_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组"},{"_id":"6a5dc9acf1c10c8ce825a6f6","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP","test_object_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland","methodology":"Odporność na narażenia przewodzone, wprowadzane do kabli","methodology_en":"Immunity to conducted disturbances, injected into cables","parameters":[{"name":"Częstotliwość","range":"(0,01 - 200) MHz"},{"name":"Poziom probierczy","range":"(20 - 109) dB μA"}],"parameters_en":[{"name":"Frequency","range":"(0,01 - 200) MHz"},{"name":"Test level","range":"(20 - 109) dB μA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia przewodzone, wprowadzane do kabli\nZakres:\nCzęstotliwość (0,01 - 200) MHz\nPoziom probierczy (20 - 109) dB μA","reference":"Ζ NO-06-A500:2012 p. 3.9","norm_bases":["Ζ NO-06-A500:2012 p. 3.9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP Odporność na narażenia przewodzone, wprowadzane do kabli\nZakres:\nCzęstotliwość (0,01 - 200) MHz\nPoziom probierczy (20 - 109) dB μA Ζ NO-06-A500:2012 p. 3.9 Urzadzenia lub zestawy urzadzen elektrycznych, elektromechanicznych i elektronicznych przeznaczone do uzytkowania w Silach, Zbrojnych RP Odpornosc na narazenia przewodzone, wprowadzane do kabli\nZakres:\nCzestotliwosc (0,01 - 200) MHz\nPoziom probierczy (20 - 109) dB μA Ζ NO-06-A500:2012 p. 3.9","categories":["electronics"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Immunity to conducted disturbances, injected into cables Frequency Test level Ζ NO-06-A500:2012 p. 3.9","parameters_zh":[{"name":"频率","range":"(0,01 - 200) MHz"},{"name":"试验等级","range":"(20 - 109) dB μA"}],"search_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组 频率 试验等级 Ζ NO-06-A500:2012 p. 3.9","test_object_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组"},{"_id":"6a5dc9acf1c10c8ce825a6f7","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP","test_object_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland","methodology":"Emisje przewodzone, przewody zasilające","methodology_en":"Conducted emissions, power supply leads","parameters":[{"name":"Częstotliwość","range":"(0,01 - 10) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,01 - 10) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje przewodzone, przewody zasilające\nCzęstotliwość (0,01 - 10) MHz","reference":"Ζ NO-06-A500:2012 p. 3.2","norm_bases":["Ζ NO-06-A500:2012 p. 3.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP Emisje przewodzone, przewody zasilające\nCzęstotliwość (0,01 - 10) MHz Ζ NO-06-A500:2012 p. 3.2 Urzadzenia lub zestawy urzadzen elektrycznych, elektromechanicznych i elektronicznych przeznaczone do uzytkowania w Silach, Zbrojnych RP Emisje przewodzone, przewody zasilajace\nCzestotliwosc (0,01 - 10) MHz Ζ NO-06-A500:2012 p. 3.2","categories":["electronics"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Conducted emissions, power supply leads Frequency Ζ NO-06-A500:2012 p. 3.2","parameters_zh":[{"name":"频率","range":"(0,01 - 10) MHz"}],"search_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组 频率 Ζ NO-06-A500:2012 p. 3.2","test_object_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组"},{"_id":"6a5dc9acf1c10c8ce825a6f8","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP","test_object_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland","methodology":"Emisje promieniowane, pole elektryczne","methodology_en":"Radiated emissions, electric field","parameters":[{"name":"Częstotliwość","range":"(0,00001 - 18) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,00001 - 18) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje promieniowane, pole elektryczne\nCzęstotliwość (0,00001 - 18) GHz","reference":"Ζ NO-06-A500:2012 p. 3.14","norm_bases":["Ζ NO-06-A500:2012 p. 3.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia lub zestawy urządzeń elektrycznych, elektromechanicznych i elektronicznych przeznaczone do użytkowania w Siłach, Zbrojnych RP Emisje promieniowane, pole elektryczne\nCzęstotliwość (0,00001 - 18) GHz Ζ NO-06-A500:2012 p. 3.14 Urzadzenia lub zestawy urzadzen elektrycznych, elektromechanicznych i elektronicznych przeznaczone do uzytkowania w Silach, Zbrojnych RP Emisje promieniowane, pole elektryczne\nCzestotliwosc (0,00001 - 18) GHz Ζ NO-06-A500:2012 p. 3.14","categories":["electronics"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, electromechanical and electronic devices or sets of devices intended for use in the Armed Forces of the Republic of Poland Radiated emissions, electric field Frequency Ζ NO-06-A500:2012 p. 3.14","parameters_zh":[{"name":"频率","range":"(0,00001 - 18) GHz"}],"search_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组 频率 Ζ NO-06-A500:2012 p. 3.14","test_object_zh":"供波兰武装部队使用的电气、机电与电子设备或设备组"},{"_id":"6a5dc9acf1c10c8ce825a6f9","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przedmiot badań/wyrób","test_object_en":"Test object/product","methodology":"Rodzaj działalności/badane cechy/metody","methodology_en":"Type of activity/tested characteristics/methods","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rodzaj działalności/badane cechy/metody","reference":"Dokumenty odniesienia","norm_bases":["Dokumenty odniesienia"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metody Dokumenty odniesienia Przedmiot badan/wyrob Rodzaj dzialalnosci/badane cechy/metody Dokumenty odniesienia","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Test object/product Type of activity/tested characteristics/methods Dokumenty odniesienia","search_zh":"检测对象/产品 Dokumenty odniesienia","test_object_zh":"检测对象/产品"},{"_id":"6a5dc9acf1c10c8ce825a6fa","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na wyładowania elektrostatyczne","methodology_en":"Immunity to electrostatic discharge","parameters":[{"name":"Poziom probierczy","range":"(0,2 - 30) kV"}],"parameters_en":[{"name":"Test level","range":"(0,2 - 30) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV","reference":"Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-2:2011","PN-EN 60255-26:2014-01 p. 7.2.3","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na wyładowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na wyladowania elektrostatyczne\nPoziom probierczy (0,2 - 30) kV Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrostatic discharge Test level Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0,2 - 30) kV"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 静电放电抗扰度 试验等级 Ζ | PN-EN 61000-4-2:2011 | PN-EN 60255-26:2014-01 p. 7.2.3 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"静电放电抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6fb","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej","methodology_en":"Immunity to radiated radio-frequency electromagnetic field","parameters":[{"name":"Częstotliwość","range":"(0,08 - 6) GHz"},{"name":"Badanie w komorze semibezodbiciowej SAC"}],"parameters_en":[{"name":"Frequency","range":"(0,08 - 6) GHz"},{"name":"Testing in a semi-anechoic chamber SAC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,08 - 6) GHz\nBadanie w komorze semibezodbiciowej SAC","reference":"Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-3:2021-06,","PN-EN 60255-26:2014-01 p. 7.2.4","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,08 - 6) GHz\nBadanie w komorze semibezodbiciowej SAC Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej\nZakres:\nCzestotliwosc (0,08 - 6) GHz\nBadanie w komorze semibezodbiciowej SAC Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to radiated radio-frequency electromagnetic field Frequency Testing in a semi-anechoic chamber SAC Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,08 - 6) GHz"},{"name":"Badanie w komorze semibezodbiciowej SAC"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 射频辐射电磁场抗扰度 频率 Ζ | PN-EN IEC 61000-4-3:2021-06, | PN-EN 60255-26:2014-01 p. 7.2.4 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"射频辐射电磁场抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6fc","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych","methodology_en":"Immunity to electrical fast transients/bursts","parameters":[{"name":"Poziom probierczy","range":"(0,25 - 5,5) kV"},{"name":"przy częstotliwości powtarzania 5 kHz i 100 kHz"}],"parameters_en":[{"name":"Test level","range":"(0,25 - 5,5) kV"},{"name":"at a repetition frequency of 5 kHz and 100 kHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres:\nPoziom probierczy (0,25 - 5,5) kV\nprzy częstotliwości powtarzania 5 kHz i 100 kHz","reference":"Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-4:2013-05","PN-EN 60255-26:2014-01 p. 7.2.5","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na serie szybkich elektrycznych stanów przejściowych\nZakres:\nPoziom probierczy (0,25 - 5,5) kV\nprzy częstotliwości powtarzania 5 kHz i 100 kHz Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na serie szybkich elektrycznych stanow przejsciowych\nZakres:\nPoziom probierczy (0,25 - 5,5) kV\nprzy czestotliwosci powtarzania 5 kHz i 100 kHz Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to electrical fast transients/bursts Test level at a repetition frequency of 5 kHz and 100 kHz Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0,25 - 5,5) kV"},{"name":"przy częstotliwości powtarzania 5 kHz i 100 kHz"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 电快速瞬变脉冲群抗扰度 试验等级 Ζ | PN-EN 61000-4-4:2013-05 | PN-EN 60255-26:2014-01 p. 7.2.5 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"电快速瞬变脉冲群抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6fd","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na udary","methodology_en":"Immunity to surges","parameters":[{"name":"Poziom probierczy","range":"(0,5 - 6) kV"}],"parameters_en":[{"name":"Test level","range":"(0,5 - 6) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary\nPoziom probierczy (0,5 - 6) kV","reference":"Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-5:2014-10","PN-EN 61000-4-5:2014-10/A1:2018-01","PN-EN 60255-26:2014-01 p. 7.2.7","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na udary\nPoziom probierczy (0,5 - 6) kV Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na udary\nPoziom probierczy (0,5 - 6) kV Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to surges Test level Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0,5 - 6) kV"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 浪涌抗扰度 试验等级 Ζ | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60255-26:2014-01 p. 7.2.7 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"浪涌抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6fe","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields","parameters":[{"name":"Częstotliwość","range":"(0,01 - 400) MHz"},{"name":"Poziom probierczy","range":"(0,1 - 20) V"}],"parameters_en":[{"name":"Frequency","range":"(0,01 - 400) MHz"},{"name":"Test level","range":"(0,1 - 20) V"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,01 - 400) MHz\nPoziom probierczy (0,1 - 20) V","reference":"Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-6:2024-03","PN-EN 60255-26:2014-01 p. 7.2.8","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej\nZakres:\nCzęstotliwość (0,01 - 400) MHz\nPoziom probierczy (0,1 - 20) V Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej\nZakres:\nCzestotliwosc (0,01 - 400) MHz\nPoziom probierczy (0,1 - 20) V Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to conducted disturbances induced by radio-frequency fields Frequency Test level Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,01 - 400) MHz"},{"name":"试验等级","range":"(0,1 - 20) V"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 射频场感应的传导骚扰抗扰度 频率 试验等级 Ζ | PN-EN IEC 61000-4-6:2024-03 | PN-EN 60255-26:2014-01 p. 7.2.8 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"射频场感应的传导骚扰抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a6ff","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[{"name":"Poziom probierczy","range":"(1 - 1000) A/m"}],"parameters_en":[{"name":"Test level","range":"(1 - 1000) A/m"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nPoziom probierczy (1 - 1000) A/m","reference":"Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-8:2010","PN-EN 60255-26:2014-01 p. 7.2.10","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej\nPoziom probierczy (1 - 1000) A/m Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej\nPoziom probierczy (1 - 1000) A/m Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to power-frequency magnetic field Test level Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(1 - 1000) A/m"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 工频磁场抗扰度 试验等级 Ζ | PN-EN 61000-4-8:2010 | PN-EN 60255-26:2014-01 p. 7.2.10 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"工频磁场抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a700","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m","methodology_en":"Immunity to pulse magnetic field, Test level: (100 - 1000) A/m","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m","reference":"Ζ | PN-EN 61000-4-9:2016-11","norm_bases":["Ζ","PN-EN 61000-4-9:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na impulsowe pole magnetyczne, Poziom probierczy: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11","categories":["electronics"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to pulse magnetic field, Test level: (100 - 1000) A/m Ζ | PN-EN 61000-4-9:2016-11","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） Ζ | PN-EN 61000-4-9:2016-11","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a701","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na pole magnetyczne oscylacyjne tłumione","methodology_en":"Immunity to damped oscillatory magnetic field","parameters":[{"name":"Poziom probierczy","range":"(10 - 100) A/m"}],"parameters_en":[{"name":"Test level","range":"(10 - 100) A/m"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne oscylacyjne tłumione\nPoziom probierczy (10 - 100) A/m","reference":"Ζ | PN-EN 61000-4-10:2017-04","norm_bases":["Ζ","PN-EN 61000-4-10:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na pole magnetyczne oscylacyjne tłumione\nPoziom probierczy (10 - 100) A/m Ζ | PN-EN 61000-4-10:2017-04 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na pole magnetyczne oscylacyjne tlumione\nPoziom probierczy (10 - 100) A/m Ζ | PN-EN 61000-4-10:2017-04","categories":["electronics"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory magnetic field Test level Ζ | PN-EN 61000-4-10:2017-04","parameters_zh":[{"name":"试验等级","range":"(10 - 100) A/m"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 试验等级 Ζ | PN-EN 61000-4-10:2017-04","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a702","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations","parameters":[{"name":"Poziom probierczy","range":"(0% - 100%) UT"}],"parameters_en":[{"name":"Test level","range":"(0% - 100%) UT"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nPoziom probierczy (0% - 100%) UT","reference":"Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-11:2020-11","PN-EN IEC 61000-4-11:2020-11/AC:2020-12","PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3","PN-EN 61000-4-34:2009","PN-EN 61000-4-34:2009/A1:2010","PN-EN 60255-26:2014-01 p. 7.2.11","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia\nPoziom probierczy (0% - 100%) UT Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia\nPoziom probierczy (0% - 100%) UT Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wylaczeniem p. 5.3 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations Test level Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0% - 100%) UT"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 电压暂降、短时中断与电压变化抗扰度 试验等级 Ζ | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 z wyłączeniem p. 5.3 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"电压暂降、短时中断与电压变化抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a703","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na tłumione przebiegi sinusoidalne","methodology_en":"Immunity to damped oscillatory waves","parameters":[{"name":"Poziom probierczy","range":"(0,25 - 6) kV"}],"parameters_en":[{"name":"Test level","range":"(0,25 - 6) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na tłumione przebiegi sinusoidalne\nPoziom probierczy (0,25 - 6) kV","reference":"Ζ | PN-EN 61000-4-12:2017-12","norm_bases":["Ζ","PN-EN 61000-4-12:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na tłumione przebiegi sinusoidalne\nPoziom probierczy (0,25 - 6) kV Ζ | PN-EN 61000-4-12:2017-12 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na tlumione przebiegi sinusoidalne\nPoziom probierczy (0,25 - 6) kV Ζ | PN-EN 61000-4-12:2017-12","categories":["electronics"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory waves Test level Ζ | PN-EN 61000-4-12:2017-12","parameters_zh":[{"name":"试验等级","range":"(0,25 - 6) kV"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 试验等级 Ζ | PN-EN 61000-4-12:2017-12","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a704","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zaburzenia małej częstotliwości","methodology_en":"Immunity to low-frequency disturbances","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia małej częstotliwości","reference":"Ζ | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05","norm_bases":["Ζ","PN-EN 61000-4-13:2007","PN-EN 61000-4-13:2007/A1:2010","PN-EN 61000-4-13:2007/A2:2016-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zaburzenia małej częstotliwości Ζ | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zaburzenia malej czestotliwosci Ζ | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05","categories":["electronics"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to low-frequency disturbances Ζ | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 低频骚扰抗扰度 Ζ | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"低频骚扰抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a705","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na asymetryczne zaburzenia przewodzone","methodology_en":"Immunity to conducted common mode disturbances","parameters":[{"name":"Częstotliwość","range":"(0 - 150) kHz"}],"parameters_en":[{"name":"Frequency","range":"(0 - 150) kHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na asymetryczne zaburzenia przewodzone\nCzęstotliwość (0 - 150) kHz","reference":"Ζ | PN-EN 61000-4-16:2016-05","norm_bases":["Ζ","PN-EN 61000-4-16:2016-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na asymetryczne zaburzenia przewodzone\nCzęstotliwość (0 - 150) kHz Ζ | PN-EN 61000-4-16:2016-05 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na asymetryczne zaburzenia przewodzone\nCzestotliwosc (0 - 150) kHz Ζ | PN-EN 61000-4-16:2016-05","categories":["electronics"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to conducted common mode disturbances Frequency Ζ | PN-EN 61000-4-16:2016-05","parameters_zh":[{"name":"频率","range":"(0 - 150) kHz"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 频率 Ζ | PN-EN 61000-4-16:2016-05","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a706","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na obecność składowej zmiennej w stałym napięciu zasilającym","methodology_en":"Immunity to ripple on the DC input power port","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obecność składowej zmiennej w stałym napięciu zasilającym","reference":"Ζ | PN-EN 61000-4-17:2004 | PN-EN 61000-4-17:2004/A1:2006 | PN-EN 61000-4-17:2004/A2:2011 | PN-EN 60255-26:2014-01 p. 7.2.12 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-17:2004","PN-EN 61000-4-17:2004/A1:2006","PN-EN 61000-4-17:2004/A2:2011","PN-EN 60255-26:2014-01 p. 7.2.12","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na obecność składowej zmiennej w stałym napięciu zasilającym Ζ | PN-EN 61000-4-17:2004 | PN-EN 61000-4-17:2004/A1:2006 | PN-EN 61000-4-17:2004/A2:2011 | PN-EN 60255-26:2014-01 p. 7.2.12 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na obecnosc skladowej zmiennej w stalym napieciu zasilajacym Ζ | PN-EN 61000-4-17:2004 | PN-EN 61000-4-17:2004/A1:2006 | PN-EN 61000-4-17:2004/A2:2011 | PN-EN 60255-26:2014-01 p. 7.2.12 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to ripple on the DC input power port Ζ | PN-EN 61000-4-17:2004 | PN-EN 61000-4-17:2004/A1:2006 | PN-EN 61000-4-17:2004/A2:2011 | PN-EN 60255-26:2014-01 p. 7.2.12 | PN-EN 60255-26:2014-01/AC:2014-06","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） Ζ | PN-EN 61000-4-17:2004 | PN-EN 61000-4-17:2004/A1:2006 | PN-EN 61000-4-17:2004/A2:2011 | PN-EN 60255-26:2014-01 p. 7.2.12 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a707","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na tłumiony przebieg oscylacyjny","methodology_en":"Immunity to damped oscillatory wave","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na tłumiony przebieg oscylacyjny","reference":"Ζ | PN-EN IEC 61000-4-18:2019-08 | PN-EN IEC 61000-4-18:2019-08/AC:2019-12 | PN-EN 60255-26:2014-01 p. 7.2.6 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN IEC 61000-4-18:2019-08","PN-EN IEC 61000-4-18:2019-08/AC:2019-12","PN-EN 60255-26:2014-01 p. 7.2.6","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na tłumiony przebieg oscylacyjny Ζ | PN-EN IEC 61000-4-18:2019-08 | PN-EN IEC 61000-4-18:2019-08/AC:2019-12 | PN-EN 60255-26:2014-01 p. 7.2.6 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na tlumiony przebieg oscylacyjny Ζ | PN-EN IEC 61000-4-18:2019-08 | PN-EN IEC 61000-4-18:2019-08/AC:2019-12 | PN-EN 60255-26:2014-01 p. 7.2.6 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to damped oscillatory wave Ζ | PN-EN IEC 61000-4-18:2019-08 | PN-EN IEC 61000-4-18:2019-08/AC:2019-12 | PN-EN 60255-26:2014-01 p. 7.2.6 | PN-EN 60255-26:2014-01/AC:2014-06","search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 阻尼振荡波抗扰度 Ζ | PN-EN IEC 61000-4-18:2019-08 | PN-EN IEC 61000-4-18:2019-08/AC:2019-12 | PN-EN 60255-26:2014-01 p. 7.2.6 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）","methodology_zh":"阻尼振荡波抗扰度"},{"_id":"6a5dc9acf1c10c8ce825a708","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU)","test_object_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU)","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia występujące w przyłączu zasilającym prądem stałym","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations occurring at the DC power port","parameters":[{"name":"Poziom probierczy","range":"(0 - 120)% UT"}],"parameters_en":[{"name":"Test level","range":"(0 - 120)% UT"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia występujące w przyłączu zasilającym prądem stałym\nPoziom probierczy (0 - 120)% UT","reference":"Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 61000-4-29:2004","PN-EN 60255-26:2014-01 p. 7.2.11","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia występujące w przyłączu zasilającym prądem stałym\nPoziom probierczy (0 - 120)% UT Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06 Urzadzenia elektryczne i elektroniczne (badania wykonywane w siedzibie laboratorium oraz w miejscu instalacji / IN SITU) Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia wystepujace w przylaczu zasilajacym pradem stalym\nPoziom probierczy (0 - 120)% UT Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["electronics"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment (testing performed at the laboratory premises and at the installation site / IN SITU) Immunity to voltage dips, short interruptions and voltage variations occurring at the DC power port Test level Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"试验等级","range":"(0 - 120)% UT"}],"search_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测） 试验等级 Ζ | PN-EN 61000-4-29:2004 | PN-EN 60255-26:2014-01 p. 7.2.11 | PN-EN 60255-26:2014-01/AC:2014-06","test_object_zh":"电气与电子设备（在实验室场所及安装现场 / IN SITU 进行的检测）"},{"_id":"6a5dc9acf1c10c8ce825a709","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","norm_bases":["Ζ","PN-EN 55016-2-1:2014-09","PN-EN 55016-2-1:2014-09/A1:2017-12","PN-EN 55016-2-1:2014-09/AC:2020-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 Urzadzenia elektryczne i elektroniczne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","categories":["electronics"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"电气与电子设备 电源端子骚扰电压 频率 Ζ | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11","test_object_zh":"电气与电子设备","methodology_zh":"电源端子骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a70a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 6) GHz"},{"name":"oraz w miejscu instalacji / IN SITU"},{"name":"Częstotliwość","range":"(0,03 - 1) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 6) GHz"},{"name":"and at the installation site / IN SITU"},{"name":"Frequency","range":"(0,03 - 1) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 6) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz","reference":"Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","norm_bases":["Ζ","PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 6) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 Urzadzenia elektryczne i elektroniczne Natezenie pola elektromagnetycznego\nZakres:\nCzestotliwosc (0,0001 - 6) GHz\noraz w miejscu instalacji / IN SITU\nCzestotliwosc (0,03 - 1) GHz Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","categories":["electronics"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Electromagnetic field strength Frequency and at the installation site / IN SITU Frequency Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","parameters_zh":[{"name":"频率","range":"(0,0001 - 6) GHz"},{"name":"以及安装现场 / IN SITU"},{"name":"频率","range":"(0,03 - 1) GHz"}],"search_zh":"电气与电子设备 电磁场强度 频率 以及安装现场 / IN SITU 频率 Ζ | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01","test_object_zh":"电气与电子设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a70b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej","test_object_en":"Industrial, scientific and medical (ISM) radio-frequency equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["Ζ","PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Przemyslowe, medyczne i naukowe (PMN) urzadzenia o czestotliwosci radiowej Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial, scientific and medical (ISM) radio-frequency equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"工业、医疗与科学（ISM）射频设备 电源端子骚扰电压 频率 Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","methodology_zh":"电源端子骚扰电压","test_object_zh":"工业、医疗与科学（ISM）射频设备"},{"_id":"6a5dc9acf1c10c8ce825a70c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej","test_object_en":"Industrial, scientific and medical (ISM) radio-frequency equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 6) GHz"},{"name":"oraz w miejscu instalacji / IN SITU"},{"name":"Częstotliwość","range":"(0,03 - 1) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 6) GHz"},{"name":"and at the installation site / IN SITU"},{"name":"Frequency","range":"(0,03 - 1) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 6) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz","reference":"Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["Ζ","PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej Natężenie pola elektromagnetycznego\nZakres:\nCzęstotliwość (0,0001 - 6) GHz\noraz w miejscu instalacji / IN SITU\nCzęstotliwość (0,03 - 1) GHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Przemyslowe, medyczne i naukowe (PMN) urzadzenia o czestotliwosci radiowej Natezenie pola elektromagnetycznego\nZakres:\nCzestotliwosc (0,0001 - 6) GHz\noraz w miejscu instalacji / IN SITU\nCzestotliwosc (0,03 - 1) GHz Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial, scientific and medical (ISM) radio-frequency equipment Electromagnetic field strength Frequency and at the installation site / IN SITU Frequency Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","parameters_zh":[{"name":"频率","range":"(0,0001 - 6) GHz"},{"name":"以及安装现场 / IN SITU"},{"name":"频率","range":"(0,03 - 1) GHz"}],"search_zh":"工业、医疗与科学（ISM）射频设备 电磁场强度 频率 以及安装现场 / IN SITU 频率 Ζ | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","methodology_zh":"电磁场强度","test_object_zh":"工业、医疗与科学（ISM）射频设备"},{"_id":"6a5dc9acf1c10c8ce825a70d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","norm_bases":["Ζ","PN-EN 55022:2011 p. 9","PN-EN 55022:2011/Ap1:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07 Urzadzenia informatyczne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"信息技术设备 电源端子骚扰电压 频率 Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","test_object_zh":"信息技术设备","methodology_zh":"电源端子骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a70e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Napięcie zaburzeń na przyłączach telekomunikacyjnych","methodology_en":"Disturbance voltage at telecommunication ports","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","norm_bases":["Ζ","PN-EN 55022:2011 p. 9","PN-EN 55022:2011/Ap1:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07 Urzadzenia informatyczne Napiecie zaburzen na przylaczach telekomunikacyjnych\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment Disturbance voltage at telecommunication ports Frequency Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"信息技术设备 电信端口上的骚扰电压 频率 Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","test_object_zh":"信息技术设备","methodology_zh":"电信端口上的骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a70f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,03 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,03 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,03 - 6) GHz","reference":"Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","norm_bases":["Ζ","PN-EN 55022:2011 p. 9","PN-EN 55022:2011/Ap1:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Natężenie pola elektromagnetycznego\nCzęstotliwość (0,03 - 6) GHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07 Urzadzenia informatyczne Natezenie pola elektromagnetycznego\nCzestotliwosc (0,03 - 6) GHz Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment Electromagnetic field strength Frequency Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","parameters_zh":[{"name":"频率","range":"(0,03 - 6) GHz"}],"search_zh":"信息技术设备 电磁场强度 频率 Ζ | PN-EN 55022:2011 p. 9 | PN-EN 55022:2011/Ap1:2013-07","test_object_zh":"信息技术设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a710","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["Ζ","PN-EN 55032:2015-09","PN-EN 55032:2015-09/AC:2016-09","PN-EN 55032:2015-09/Ap1:2017-12","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"多媒体设备 电源端子骚扰电压 频率 Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","methodology_zh":"电源端子骚扰电压","test_object_zh":"多媒体设备"},{"_id":"6a5dc9acf1c10c8ce825a711","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Napięcie zaburzeń na przyłączach telekomunikacyjnych","methodology_en":"Disturbance voltage at telecommunication ports","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["Ζ","PN-EN 55032:2015-09","PN-EN 55032:2015-09/AC:2016-09","PN-EN 55032:2015-09/Ap1:2017-12","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Napiecie zaburzen na przylaczach telekomunikacyjnych\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Disturbance voltage at telecommunication ports Frequency Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"多媒体设备 电信端口上的骚扰电压 频率 Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"电信端口上的骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a712","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz","reference":"Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["Ζ","PN-EN 55032:2015-09","PN-EN 55032:2015-09/AC:2016-09","PN-EN 55032:2015-09/Ap1:2017-12","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 6) GHz Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Multimedia equipment Electromagnetic field strength Frequency Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","parameters_zh":[{"name":"频率","range":"(0,0001 - 6) GHz"}],"search_zh":"多媒体设备 电磁场强度 频率 Ζ | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a713","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe","test_object_en":"Measuring relays and protection equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 60255-26:2014-01 p. 7.1","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06 Przekazniki pomiarowe i urzadzenia zabezpieczeniowe Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measuring relays and protection equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"量度继电器与保护装置 电源端子骚扰电压 频率 Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","methodology_zh":"电源端子骚扰电压","test_object_zh":"量度继电器与保护装置"},{"_id":"6a5dc9acf1c10c8ce825a714","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe","test_object_en":"Measuring relays and protection equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz","reference":"Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","norm_bases":["Ζ","PN-EN 60255-26:2014-01 p. 7.1","PN-EN 60255-26:2014-01/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekaźniki pomiarowe i urządzenia zabezpieczeniowe Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06 Przekazniki pomiarowe i urzadzenia zabezpieczeniowe Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 6) GHz Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measuring relays and protection equipment Electromagnetic field strength Frequency Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","parameters_zh":[{"name":"频率","range":"(0,0001 - 6) GHz"}],"search_zh":"量度继电器与保护装置 电磁场强度 频率 Ζ | PN-EN 60255-26:2014-01 p. 7.1 | PN-EN 60255-26:2014-01/AC:2014-06","methodology_zh":"电磁场强度","test_object_zh":"量度继电器与保护装置"},{"_id":"6a5dc9acf1c10c8ce825a715","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Disturbance voltage at the mains terminals Frequency Ζ | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"家用器具、电动工具及类似设备 电源端子骚扰电压 频率 Ζ | PN-EN IEC 55014-1:2021-08","methodology_zh":"电源端子骚扰电压","test_object_zh":"家用器具、电动工具及类似设备"},{"_id":"6a5dc9acf1c10c8ce825a716","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Napięcie zaburzeń na przyłączach telekomunikacyjnych","methodology_en":"Disturbance voltage at telecommunication ports","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Napięcie zaburzeń na przyłączach telekomunikacyjnych\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Napiecie zaburzen na przylaczach telekomunikacyjnych\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Disturbance voltage at telecommunication ports Frequency Ζ | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"家用器具、电动工具及类似设备 电信端口上的骚扰电压 频率 Ζ | PN-EN IEC 55014-1:2021-08","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"电信端口上的骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a717","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz","reference":"Ζ | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz Ζ | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 6) GHz Ζ | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Electromagnetic field strength Frequency Ζ | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,0001 - 6) GHz"}],"search_zh":"家用器具、电动工具及类似设备 电磁场强度 频率 Ζ | PN-EN IEC 55014-1:2021-08","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a718","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","test_object_en":"Household appliances, electric tools and similar apparatus","methodology":"Moc zaburzeń","methodology_en":"Disturbance power","parameters":[{"name":"Częstotliwość","range":"(0,03 - 1) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,03 - 1) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc zaburzeń\nCzęstotliwość (0,03 - 1) GHz","reference":"Ζ | PN-EN 55016-2-2:2011 | PN-EN 55016-2-2:2011/Ap1:2013-06 | PN-EN IEC 55014-1:2021-08","norm_bases":["Ζ","PN-EN 55016-2-2:2011","PN-EN 55016-2-2:2011/Ap1:2013-06","PN-EN IEC 55014-1:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Moc zaburzeń\nCzęstotliwość (0,03 - 1) GHz Ζ | PN-EN 55016-2-2:2011 | PN-EN 55016-2-2:2011/Ap1:2013-06 | PN-EN IEC 55014-1:2021-08 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Moc zaburzen\nCzestotliwosc (0,03 - 1) GHz Ζ | PN-EN 55016-2-2:2011 | PN-EN 55016-2-2:2011/Ap1:2013-06 | PN-EN IEC 55014-1:2021-08","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Household appliances, electric tools and similar apparatus Disturbance power Frequency Ζ | PN-EN 55016-2-2:2011 | PN-EN 55016-2-2:2011/Ap1:2013-06 | PN-EN IEC 55014-1:2021-08","parameters_zh":[{"name":"频率","range":"(0,03 - 1) GHz"}],"search_zh":"家用器具、电动工具及类似设备 频率 Ζ | PN-EN 55016-2-2:2011 | PN-EN 55016-2-2:2011/Ap1:2013-06 | PN-EN IEC 55014-1:2021-08","test_object_zh":"家用器具、电动工具及类似设备"},{"_id":"6a5dc9acf1c10c8ce825a719","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","test_object_en":"Electrical lighting and similar equipment","methodology":"Napięcie zaburzeń na zaciskach zasilania","methodology_en":"Disturbance voltage at the mains terminals","parameters":[{"name":"Częstotliwość","range":"(0,009 - 30) MHz"}],"parameters_en":[{"name":"Frequency","range":"(0,009 - 30) MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz","reference":"Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","norm_bases":["Ζ","PN-EN IEC 55015:2019-11","PN-EN IEC 55015:2019-11/A11:2020-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Napięcie zaburzeń na zaciskach zasilania\nCzęstotliwość (0,009 - 30) MHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Napiecie zaburzen na zaciskach zasilania\nCzestotliwosc (0,009 - 30) MHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical lighting and similar equipment Disturbance voltage at the mains terminals Frequency Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","parameters_zh":[{"name":"频率","range":"(0,009 - 30) MHz"}],"search_zh":"电气照明设备及类似设备 电源端子骚扰电压 频率 Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","test_object_zh":"电气照明设备及类似设备","methodology_zh":"电源端子骚扰电压"},{"_id":"6a5dc9acf1c10c8ce825a71a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","test_object_en":"Electrical lighting and similar equipment","methodology":"Natężenie pola elektromagnetycznego","methodology_en":"Electromagnetic field strength","parameters":[{"name":"Częstotliwość","range":"(0,0001 - 6) GHz"}],"parameters_en":[{"name":"Frequency","range":"(0,0001 - 6) GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz","reference":"Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","norm_bases":["Ζ","PN-EN IEC 55015:2019-11","PN-EN IEC 55015:2019-11/A11:2020-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Natężenie pola elektromagnetycznego\nCzęstotliwość (0,0001 - 6) GHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Natezenie pola elektromagnetycznego\nCzestotliwosc (0,0001 - 6) GHz Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical lighting and similar equipment Electromagnetic field strength Frequency Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","parameters_zh":[{"name":"频率","range":"(0,0001 - 6) GHz"}],"search_zh":"电气照明设备及类似设备 电磁场强度 频率 Ζ | PN-EN IEC 55015:2019-11 | PN-EN IEC 55015:2019-11/A11:2020-07","test_object_zh":"电气照明设备及类似设备","methodology_zh":"电磁场强度"},{"_id":"6a5dc9acf1c10c8ce825a71b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Harmoniczne i interharmoniczne prądu","methodology_en":"Current harmonics and interharmonics","parameters":[{"name":"Zakres","range":"(2 - 40) harmonicznej"}],"parameters_en":[{"name":"Range","range":"(2 - 40) harmonicznej"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Harmoniczne i interharmoniczne prądu\nZakres (2 - 40) harmonicznej","reference":"Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","norm_bases":["Ζ","PN-EN 61000-4-7:2007","PN-EN 61000-4-7:2007/A1:2011","PN-EN IEC 61000-3-2:2019-04","PN-EN IEC 61000-3-2:2019-04/A1:2021-08","PN-EN 61000-3-12:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Harmoniczne i interharmoniczne prądu\nZakres (2 - 40) harmonicznej Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012 Urzadzenia elektryczne i elektroniczne Harmoniczne i interharmoniczne pradu\nZakres (2 - 40) harmonicznej Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","categories":["electronics"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Current harmonics and interharmonics Range Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","parameters_zh":[{"name":"范围","range":"(2 - 40) harmonicznej"}],"search_zh":"电气与电子设备 范围 Ζ | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012","test_object_zh":"电气与电子设备"},{"_id":"6a5dc9acf1c10c8ce825a71c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Wahania napięcia i migotania światła","methodology_en":"Voltage fluctuations and flicker","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wahania napięcia i migotania światła","reference":"Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","norm_bases":["Ζ","PN-EN 61000-4-15:2011","PN-EN 61000-3-3:2013-10","PN-EN 61000-3-3:2013-10/A1:2019-10","PN-EN 61000-3-3:2013-10/A2:2022-04","PN-EN 61000-3-3:2013-10/AC:2022-05","PN-EN IEC 61000-3-11:2020-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Wahania napięcia i migotania światła Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01 Urzadzenia elektryczne i elektroniczne Wahania napiecia i migotania swiatla Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","categories":["electronics"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic equipment Voltage fluctuations and flicker Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","search_zh":"电气与电子设备 电压波动与闪烁 Ζ | PN-EN 61000-4-15:2011 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN IEC 61000-3-11:2020-01","test_object_zh":"电气与电子设备","methodology_zh":"电压波动与闪烁"},{"_id":"6a5dc9acf1c10c8ce825a71d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność izolacji powłoki lub osłony na nacisk w podwyższonej temperaturze","methodology_en":"Resistance of the insulation, sheath or covering to pressure at elevated temperature","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność izolacji powłoki lub osłony na nacisk w podwyższonej temperaturze","reference":"Ζ | PN-EN 60811-508:2012 | PN-EN 60811-508:2012/A1:2018-02 | PN-EN 60811-508:2012/A2:2024-03 | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002","norm_bases":["Ζ","PN-EN 60811-508:2012","PN-EN 60811-508:2012/A1:2018-02","PN-EN 60811-508:2012/A2:2024-03","PN-EN 60811-3-1:1999","PN-EN 60811-3-1:1999/A2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność izolacji powłoki lub osłony na nacisk w podwyższonej temperaturze Ζ | PN-EN 60811-508:2012 | PN-EN 60811-508:2012/A1:2018-02 | PN-EN 60811-508:2012/A2:2024-03 | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc izolacji powloki lub oslony na nacisk w podwyzszonej temperaturze Ζ | PN-EN 60811-508:2012 | PN-EN 60811-508:2012/A1:2018-02 | PN-EN 60811-508:2012/A2:2024-03 | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002","categories":["construction"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of the insulation, sheath or covering to pressure at elevated temperature Ζ | PN-EN 60811-508:2012 | PN-EN 60811-508:2012/A1:2018-02 | PN-EN 60811-508:2012/A2:2024-03 | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60811-508:2012 | PN-EN 60811-508:2012/A1:2018-02 | PN-EN 60811-508:2012/A2:2024-03 | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a71e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Sprawdzenie budowy i wymiarów elementów kabli i przewodów","methodology_en":"Verification of the construction and dimensions of cable and wire components","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie budowy i wymiarów elementów kabli i przewodów","reference":"Ζ | PN-EN 60851-2:2010 | PN-EN 60851-2:2010/A1:2015-09 | PN-EN 60851-2:2010/A2:2019-12 | PN-EN 60811-201:2012 | PN-EN 60811-201:2012/A1:2018-02 | PN-EN 60811-201:2012/A2:2024-03 | PN-EN 60811-202:2012 | PN-EN 60811-202:2012/A1:2018-02 | PN-EN 60811-202:2012/A2:2024-03 | PN-EN 60811-203:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6) | PN-E-04160-19:1992 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","norm_bases":["Ζ","PN-EN 60851-2:2010","PN-EN 60851-2:2010/A1:2015-09","PN-EN 60851-2:2010/A2:2019-12","PN-EN 60811-201:2012","PN-EN 60811-201:2012/A1:2018-02","PN-EN 60811-201:2012/A2:2024-03","PN-EN 60811-202:2012","PN-EN 60811-202:2012/A1:2018-02","PN-EN 60811-202:2012/A2:2024-03","PN-EN 60811-203:2012","PN-EN 60811-1-1:1999","PN-EN 60811-1-1:1999/A1:2002","PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6)","PN-E-04160-19:1992","PN-EN 50396:2007","PN-EN 50396:2007/A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Sprawdzenie budowy i wymiarów elementów kabli i przewodów Ζ | PN-EN 60851-2:2010 | PN-EN 60851-2:2010/A1:2015-09 | PN-EN 60851-2:2010/A2:2019-12 | PN-EN 60811-201:2012 | PN-EN 60811-201:2012/A1:2018-02 | PN-EN 60811-201:2012/A2:2024-03 | PN-EN 60811-202:2012 | PN-EN 60811-202:2012/A1:2018-02 | PN-EN 60811-202:2012/A2:2024-03 | PN-EN 60811-203:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6) | PN-E-04160-19:1992 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Sprawdzenie budowy i wymiarow elementow kabli i przewodow Ζ | PN-EN 60851-2:2010 | PN-EN 60851-2:2010/A1:2015-09 | PN-EN 60851-2:2010/A2:2019-12 | PN-EN 60811-201:2012 | PN-EN 60811-201:2012/A1:2018-02 | PN-EN 60811-201:2012/A2:2024-03 | PN-EN 60811-202:2012 | PN-EN 60811-202:2012/A1:2018-02 | PN-EN 60811-202:2012/A2:2024-03 | PN-EN 60811-203:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.1 (z wylaczeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6) | PN-E-04160-19:1992 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Verification of the construction and dimensions of cable and wire components Ζ | PN-EN 60851-2:2010 | PN-EN 60851-2:2010/A1:2015-09 | PN-EN 60851-2:2010/A2:2019-12 | PN-EN 60811-201:2012 | PN-EN 60811-201:2012/A1:2018-02 | PN-EN 60811-201:2012/A2:2024-03 | PN-EN 60811-202:2012 | PN-EN 60811-202:2012/A1:2018-02 | PN-EN 60811-202:2012/A2:2024-03 | PN-EN 60811-203:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6) | PN-E-04160-19:1992 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60851-2:2010 | PN-EN 60851-2:2010/A1:2015-09 | PN-EN 60851-2:2010/A2:2019-12 | PN-EN 60811-201:2012 | PN-EN 60811-201:2012/A1:2018-02 | PN-EN 60811-201:2012/A2:2024-03 | PN-EN 60811-202:2012 | PN-EN 60811-202:2012/A1:2018-02 | PN-EN 60811-202:2012/A2:2024-03 | PN-EN 60811-203:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.1 (z wyłączeniem 2.1.9, 2.1.10.3, 2.1.10.4, 2.1.10.5, 2.1.10.6) | PN-E-04160-19:1992 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a71f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność na rozprzestrzenianie płomienia","methodology_en":"Resistance to flame spread","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na rozprzestrzenianie płomienia","reference":"Ζ | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010","norm_bases":["Ζ","PN-EN 60332-1-2:2010","PN-EN 60332-1-2:2010/A1:2016-02","PN-EN 60332-1-2:2010/A11:2017-02","PN-EN 60332-1-2:2010/A12:2021-05","PN-EN 60332-2-2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność na rozprzestrzenianie płomienia Ζ | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc na rozprzestrzenianie plomienia Ζ | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance to flame spread Ζ | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a720","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Rezystancja przejścia między ekranem a żyłą ochronną w przewodach oponowych","methodology_en":"Transition resistance between the screen and the protective core in rubber-sheathed cables","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja przejścia między ekranem a żyłą ochronną w przewodach oponowych","reference":"Ζ | PN-E-04160-68:1988 | PN-G-42010:1997","norm_bases":["Ζ","PN-E-04160-68:1988","PN-G-42010:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Rezystancja przejścia między ekranem a żyłą ochronną w przewodach oponowych Ζ | PN-E-04160-68:1988 | PN-G-42010:1997 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Rezystancja przejscia miedzy ekranem a zyla ochronna w przewodach oponowych Ζ | PN-E-04160-68:1988 | PN-G-42010:1997","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Transition resistance between the screen and the protective core in rubber-sheathed cables Ζ | PN-E-04160-68:1988 | PN-G-42010:1997","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-68:1988 | PN-G-42010:1997","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a721","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Podatność na nawijanie","methodology_en":"Susceptibility to winding","parameters":[{"name":"zakres","range":"(od - 70 do +250) °C"}],"parameters_en":[{"name":"range","range":"(od - 70 do +250) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność na nawijanie\nzakres (od - 70 do +250) °C","reference":"Ζ | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 | PN-EN 60811-504:2012 | PN-EN 60811-509:2012 | PN-EN 60811-509:2012/A1:2018-02","norm_bases":["Ζ","PN-EN 60811-3-1:1999","PN-EN 60811-3-1:1999/A2:2002","PN-EN 60811-1-4:1999","PN-EN 60811-1-4:1999/A2:2002","PN-EN 60811-504:2012","PN-EN 60811-509:2012","PN-EN 60811-509:2012/A1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Podatność na nawijanie\nzakres (od - 70 do +250) °C Ζ | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 | PN-EN 60811-504:2012 | PN-EN 60811-509:2012 | PN-EN 60811-509:2012/A1:2018-02 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Podatnosc na nawijanie\nzakres (od - 70 do +250) °C Ζ | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 | PN-EN 60811-504:2012 | PN-EN 60811-509:2012 | PN-EN 60811-509:2012/A1:2018-02","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Susceptibility to winding range Ζ | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 | PN-EN 60811-504:2012 | PN-EN 60811-509:2012 | PN-EN 60811-509:2012/A1:2018-02","parameters_zh":[{"name":"范围","range":"(od - 70 do +250) °C"}],"search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 范围 Ζ | PN-EN 60811-3-1:1999 | PN-EN 60811-3-1:1999/A2:2002 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 | PN-EN 60811-504:2012 | PN-EN 60811-509:2012 | PN-EN 60811-509:2012/A1:2018-02","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a722","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Szczelność wzdłużna (penetracja wody)","methodology_en":"Longitudinal watertightness (water penetration)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność wzdłużna (penetracja wody)","reference":"Ζ | PN-HD 605-S3:2020-05 | IEC 60502-2:2014 zał. F | IEC 60502-2:2014/AMD1:2024","norm_bases":["Ζ","PN-HD 605-S3:2020-05","IEC 60502-2:2014 zał. F","IEC 60502-2:2014/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Szczelność wzdłużna (penetracja wody) Ζ | PN-HD 605-S3:2020-05 | IEC 60502-2:2014 zał. F | IEC 60502-2:2014/AMD1:2024 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Szczelnosc wzdluzna (penetracja wody) Ζ | PN-HD 605-S3:2020-05 | IEC 60502-2:2014 zal. F | IEC 60502-2:2014/AMD1:2024","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Longitudinal watertightness (water penetration) Ζ | PN-HD 605-S3:2020-05 | IEC 60502-2:2014 zał. F | IEC 60502-2:2014/AMD1:2024","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-HD 605-S3:2020-05 | IEC 60502-2:2014 zał. F | IEC 60502-2:2014/AMD1:2024","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a723","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Wydłużenie trwałe w podwyższonej temperaturze","methodology_en":"Permanent elongation at elevated temperature","parameters":[{"name":"zakres","range":"do 150 °C"}],"parameters_en":[{"name":"range","range":"do 150 °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie trwałe w podwyższonej temperaturze\nzakres do 150 °C","reference":"Ζ | PN-EN 60811-507:2012 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002","norm_bases":["Ζ","PN-EN 60811-507:2012","PN-EN 60811-2-1:1999","PN-EN 60811-2-1:1999/A1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Wydłużenie trwałe w podwyższonej temperaturze\nzakres do 150 °C Ζ | PN-EN 60811-507:2012 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Wydluzenie trwale w podwyzszonej temperaturze\nzakres do 150 °C Ζ | PN-EN 60811-507:2012 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Permanent elongation at elevated temperature range Ζ | PN-EN 60811-507:2012 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002","parameters_zh":[{"name":"范围","range":"do 150 °C"}],"search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 范围 Ζ | PN-EN 60811-507:2012 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a724","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność przewodów na wielokrotne zginanie zakres: przekrój znamionowy żył (0,35 - 4) mm2","methodology_en":"Resistance of cables to repeated bending range: nominal conductor cross-section (0,35 - 4) mm2","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność przewodów na wielokrotne zginanie zakres: przekrój znamionowy żył (0,35 - 4) mm2","reference":"Ζ | PN-E-04160-25:1989 | PN-E-04160-25:1989/Az1:1998 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","norm_bases":["Ζ","PN-E-04160-25:1989","PN-E-04160-25:1989/Az1:1998","PN-EN 50396:2007","PN-EN 50396:2007/A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność przewodów na wielokrotne zginanie zakres: przekrój znamionowy żył (0,35 - 4) mm2 Ζ | PN-E-04160-25:1989 | PN-E-04160-25:1989/Az1:1998 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc przewodow na wielokrotne zginanie zakres: przekroj znamionowy zyl (0,35 - 4) mm2 Ζ | PN-E-04160-25:1989 | PN-E-04160-25:1989/Az1:1998 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of cables to repeated bending range: nominal conductor cross-section (0,35 - 4) mm2 Ζ | PN-E-04160-25:1989 | PN-E-04160-25:1989/Az1:1998 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-25:1989 | PN-E-04160-25:1989/Az1:1998 | PN-EN 50396:2007 | PN-EN 50396:2007/A1:2011","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a725","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Rezystancja żył i innych elementów metalowych","methodology_en":"Resistance of cores and other metal elements","parameters":[{"name":"zakres","range":"(10-5 - 105) Ω"}],"parameters_en":[{"name":"range","range":"(10-5 - 105) Ω"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja żył i innych elementów metalowych\nzakres (10-5 - 105) Ω","reference":"Ζ | PN-E-04160-70:1983 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60228:2025-02 | PN-EN 50289-1-2:2007","norm_bases":["Ζ","PN-E-04160-70:1983","PN-EN 60851-5:2008","PN-EN 60851-5:2008/A1:2011","PN-EN 60851-5:2008/A2:2020-06","PN-HD 605-S3:2020-05","PN-EN 50395:2007","PN-EN 50395:2007/A1:2011","PN-EN 60228:2025-02","PN-EN 50289-1-2:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Rezystancja żył i innych elementów metalowych\nzakres (10-5 - 105) Ω Ζ | PN-E-04160-70:1983 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60228:2025-02 | PN-EN 50289-1-2:2007 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Rezystancja zyl i innych elementow metalowych\nzakres (10-5 - 105) Ω Ζ | PN-E-04160-70:1983 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60228:2025-02 | PN-EN 50289-1-2:2007","categories":["materials"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of cores and other metal elements range Ζ | PN-E-04160-70:1983 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60228:2025-02 | PN-EN 50289-1-2:2007","parameters_zh":[{"name":"范围","range":"(10-5 - 105) Ω"}],"search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 范围 Ζ | PN-E-04160-70:1983 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60228:2025-02 | PN-EN 50289-1-2:2007","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a726","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Ubytek masy izolacji i powłok polwinitowych","methodology_en":"Mass loss of PVC insulation and sheaths","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ubytek masy izolacji i powłok polwinitowych","reference":"Ζ | PN-EN 60811-409:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","norm_bases":["Ζ","PN-EN 60811-409:2012","PN-EN 60811-3-2:1999","PN-EN 60811-3-2:1999/A2:2005","PN-EN 60811-3-2:1999/Ap1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Ubytek masy izolacji i powłok polwinitowych Ζ | PN-EN 60811-409:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Ubytek masy izolacji i powlok polwinitowych Ζ | PN-EN 60811-409:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","categories":["construction"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Mass loss of PVC insulation and sheaths Ζ | PN-EN 60811-409:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60811-409:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a727","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność kabla lub przewodu na uderzenia zakres: do – 70 °C","methodology_en":"Resistance of the cable or wire to impact range: down to – 70 °C","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kabla lub przewodu na uderzenia zakres: do – 70 °C","reference":"Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 | PN-EN 60811-506:2012 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002","norm_bases":["Ζ","PN-E-04160-24:1991","PN-E-04160-24:1991/Az1:1996","PN-EN 60811-506:2012","PN-EN 60811-1-4:1999","PN-EN 60811-1-4:1999/A2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność kabla lub przewodu na uderzenia zakres: do – 70 °C Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 | PN-EN 60811-506:2012 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc kabla lub przewodu na uderzenia zakres: do – 70 °C Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 | PN-EN 60811-506:2012 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of the cable or wire to impact range: down to – 70 °C Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 | PN-EN 60811-506:2012 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 | PN-EN 60811-506:2012 | PN-EN 60811-1-4:1999 | PN-EN 60811-1-4:1999/A2:2002","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a728","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność przewodu na wielokrotne zginanie przy jednoczesnym skręcaniu zakres: przekrój znamionowy (6 - 120) mm2","methodology_en":"Resistance of the cable to repeated bending with simultaneous twisting range: nominal cross-section (6 - 120) mm2","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność przewodu na wielokrotne zginanie przy jednoczesnym skręcaniu zakres: przekrój znamionowy (6 - 120) mm2","reference":"Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996","norm_bases":["Ζ","PN-E-04160-24:1991","PN-E-04160-24:1991/Az1:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność przewodu na wielokrotne zginanie przy jednoczesnym skręcaniu zakres: przekrój znamionowy (6 - 120) mm2 Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc przewodu na wielokrotne zginanie przy jednoczesnym skrecaniu zakres: przekroj znamionowy (6 - 120) mm2 Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance of the cable to repeated bending with simultaneous twisting range: nominal cross-section (6 - 120) mm2 Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-24:1991 | PN-E-04160-24:1991/Az1:1996","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a729","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Nasiąkliwość wodą przez izolację i powłokę","methodology_en":"Water absorption through insulation and sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość wodą przez izolację i powłokę","reference":"Ζ | PN-EN 60811-402:2012 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002","norm_bases":["Ζ","PN-EN 60811-402:2012","PN-EN 60811-1-3:1999","PN-EN 60811-1-3:1999/A1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Nasiąkliwość wodą przez izolację i powłokę Ζ | PN-EN 60811-402:2012 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Nasiakliwosc woda przez izolacje i powloke Ζ | PN-EN 60811-402:2012 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002","categories":["construction"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Water absorption through insulation and sheath Ζ | PN-EN 60811-402:2012 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60811-402:2012 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a72a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Skurcz izolacji i powłoki","methodology_en":"Shrinkage of the insulation and sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skurcz izolacji i powłoki","reference":"Ζ | PN-EN 60811-502:2012 | PN-EN 60811-503:2012 | PN-EN 60811-503:2012/A1:2024-03 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.4.4.1","norm_bases":["Ζ","PN-EN 60811-502:2012","PN-EN 60811-503:2012","PN-EN 60811-503:2012/A1:2024-03","PN-EN 60811-1-3:1999","PN-EN 60811-1-3:1999/A1:2002","PN-HD 605-S3:2020-05 p. 2.4.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Skurcz izolacji i powłoki Ζ | PN-EN 60811-502:2012 | PN-EN 60811-503:2012 | PN-EN 60811-503:2012/A1:2024-03 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.4.4.1 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Skurcz izolacji i powloki Ζ | PN-EN 60811-502:2012 | PN-EN 60811-503:2012 | PN-EN 60811-503:2012/A1:2024-03 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.4.4.1","categories":["construction"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Shrinkage of the insulation and sheath Ζ | PN-EN 60811-502:2012 | PN-EN 60811-503:2012 | PN-EN 60811-503:2012/A1:2024-03 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.4.4.1","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60811-502:2012 | PN-EN 60811-503:2012 | PN-EN 60811-503:2012/A1:2024-03 | PN-EN 60811-1-3:1999 | PN-EN 60811-1-3:1999/A1:2002 | PN-HD 605-S3:2020-05 p. 2.4.4.1","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a72b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Wytrzymałość cieplna izolacji i powłoki","methodology_en":"Thermal endurance of the insulation and sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość cieplna izolacji i powłoki","reference":"Ζ | PN-EN 60811-405:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","norm_bases":["Ζ","PN-EN 60811-405:2012","PN-EN 60811-3-2:1999","PN-EN 60811-3-2:1999/A2:2005","PN-EN 60811-3-2:1999/Ap1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Wytrzymałość cieplna izolacji i powłoki Ζ | PN-EN 60811-405:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Wytrzymalosc cieplna izolacji i powloki Ζ | PN-EN 60811-405:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","categories":["construction"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Thermal endurance of the insulation and sheath Ζ | PN-EN 60811-405:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 60811-405:2012 | PN-EN 60811-3-2:1999 | PN-EN 60811-3-2:1999/A2:2005 | PN-EN 60811-3-2:1999/Ap1:2006","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a72c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność na wysoką temperaturę","methodology_en":"Resistance to high temperature","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wysoką temperaturę","reference":"Ζ | PN-HD 605-S3:2020-05","norm_bases":["Ζ","PN-HD 605-S3:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność na wysoką temperaturę Ζ | PN-HD 605-S3:2020-05 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc na wysoka temperature Ζ | PN-HD 605-S3:2020-05","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance to high temperature Ζ | PN-HD 605-S3:2020-05","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 耐高温性 Ζ | PN-HD 605-S3:2020-05","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线","methodology_zh":"耐高温性"},{"_id":"6a5dc9acf1c10c8ce825a72d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność na napięcie probiercze","methodology_en":"Withstand of the test voltage","parameters":[{"name":"napięcie probiercze zakres","range":"do 50 kV AC i"},{"name":"6 kV DC"}],"parameters_en":[{"name":"test voltage range","range":"do 50 kV AC i"},{"name":"6 kV DC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na napięcie probiercze\nZakres:\nnapięcie probiercze zakres do 50 kV AC i\n6 kV DC","reference":"Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 50289-1-3:2007","norm_bases":["Ζ","PN-HD 605-S3:2020-05","PN-EN 50395:2007","PN-EN 50395:2007/A1:2011","PN-EN 60851-5:2008","PN-EN 60851-5:2008/A1:2011","PN-EN 60851-5:2008/A2:2020-06","PN-EN 50289-1-3:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność na napięcie probiercze\nZakres:\nnapięcie probiercze zakres do 50 kV AC i\n6 kV DC Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 50289-1-3:2007 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc na napiecie probiercze\nZakres:\nnapiecie probiercze zakres do 50 kV AC i\n6 kV DC Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 50289-1-3:2007","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Withstand of the test voltage test voltage range 6 kV DC Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 50289-1-3:2007","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 60851-5:2008 | PN-EN 60851-5:2008/A1:2011 | PN-EN 60851-5:2008/A2:2020-06 | PN-EN 50289-1-3:2007","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a72e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Rezystancja i rezystywność skrośna izolacji","methodology_en":"Volume resistance and volume resistivity of insulation","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja i rezystywność skrośna izolacji","reference":"Ζ | PN-E-04160-73:1983 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 50289-1-4:2007","norm_bases":["Ζ","PN-E-04160-73:1983","PN-HD 605-S3:2020-05","PN-EN 50395:2007","PN-EN 50395:2007/A1:2011","PN-EN 50289-1-4:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Rezystancja i rezystywność skrośna izolacji Ζ | PN-E-04160-73:1983 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 50289-1-4:2007 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Rezystancja i rezystywnosc skrosna izolacji Ζ | PN-E-04160-73:1983 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 50289-1-4:2007","categories":["construction"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Volume resistance and volume resistivity of insulation Ζ | PN-E-04160-73:1983 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 50289-1-4:2007","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-73:1983 | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 | PN-EN 50289-1-4:2007","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a72f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Rezystancja powierzchniowa powłoki","methodology_en":"Surface resistance of the coating","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa powłoki","reference":"Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","norm_bases":["Ζ","PN-HD 605-S3:2020-05","PN-EN 50395:2007","PN-EN 50395:2007/A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Rezystancja powierzchniowa powłoki Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Rezystancja powierzchniowa powloki Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Surface resistance of the coating Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-HD 605-S3:2020-05 | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a730","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Odporność na długotrwałe działanie prądu stałego","methodology_en":"Resistance to long-term direct current","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na długotrwałe działanie prądu stałego","reference":"Ζ | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","norm_bases":["Ζ","PN-EN 50395:2007","PN-EN 50395:2007/A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Odporność na długotrwałe działanie prądu stałego Ζ | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Odpornosc na dlugotrwale dzialanie pradu stalego Ζ | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Resistance to long-term direct current Ζ | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-EN 50395:2007 | PN-EN 50395:2007/A1:2011","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a731","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Nagrzewanie (przyrosty temperatury)","methodology_en":"Heating (temperature rise)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nagrzewanie (przyrosty temperatury)","reference":"Ζ | PN-E-04160-69:1988","norm_bases":["Ζ","PN-E-04160-69:1988"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Nagrzewanie (przyrosty temperatury) Ζ | PN-E-04160-69:1988 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Nagrzewanie (przyrosty temperatury) Ζ | PN-E-04160-69:1988","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Heating (temperature rise) Ζ | PN-E-04160-69:1988","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-69:1988","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a732","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Pojemność skuteczna","methodology_en":"Effective capacitance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pojemność skuteczna","reference":"Ζ | PN-E-04160-77:1973 | PN-EN 50289-1-5:2008","norm_bases":["Ζ","PN-E-04160-77:1973","PN-EN 50289-1-5:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Pojemność skuteczna Ζ | PN-E-04160-77:1973 | PN-EN 50289-1-5:2008 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Pojemnosc skuteczna Ζ | PN-E-04160-77:1973 | PN-EN 50289-1-5:2008","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Effective capacitance Ζ | PN-E-04160-77:1973 | PN-EN 50289-1-5:2008","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 Ζ | PN-E-04160-77:1973 | PN-EN 50289-1-5:2008","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a733","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm","test_object_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm","methodology":"Asymetria pojemności","methodology_en":"Capacitance asymmetry","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Asymetria pojemności","reference":"PN-E-04160-78:1973","norm_bases":["PN-E-04160-78:1973"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm Asymetria pojemności PN-E-04160-78:1973 Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm Asymetria pojemnosci PN-E-04160-78:1973","categories":["other"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and wires with rated voltage up to 18/30 kV, outer diameter up to 100 mm Capacitance asymmetry PN-E-04160-78:1973","search_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线 PN-E-04160-78:1973","test_object_zh":"额定电压至 18/30 kV、外径至 100 mm 的电缆与导线"},{"_id":"6a5dc9acf1c10c8ce825a734","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przewody nawojowe okrągłe i prostokątne w emalii, średnica do 5 mm, przekrój do 15 mm x 10 mm","test_object_en":"Round and rectangular enamelled winding wires, diameter up to 5 mm, cross-section up to 15 mm x 10 mm","methodology":"Elastyczność i przyczepność., Próba nawijania na trzpień","methodology_en":"Flexibility and adhesion., Mandrel winding test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Elastyczność i przyczepność., Próba nawijania na trzpień","reference":"Ζ | PN-EN IEC 60851-3:2024-05 p. 6.2","norm_bases":["Ζ","PN-EN IEC 60851-3:2024-05 p. 6.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody nawojowe okrągłe i prostokątne w emalii, średnica do 5 mm, przekrój do 15 mm x 10 mm Elastyczność i przyczepność., Próba nawijania na trzpień Ζ | PN-EN IEC 60851-3:2024-05 p. 6.2 Przewody nawojowe okragle i prostokatne w emalii, srednica do 5 mm, przekroj do 15 mm x 10 mm Elastycznosc i przyczepnosc., Proba nawijania na trzpien Ζ | PN-EN IEC 60851-3:2024-05 p. 6.2","categories":["other"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Round and rectangular enamelled winding wires, diameter up to 5 mm, cross-section up to 15 mm x 10 mm Flexibility and adhesion., Mandrel winding test Ζ | PN-EN IEC 60851-3:2024-05 p. 6.2"},{"_id":"6a5dc9acf1c10c8ce825a735","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Przewody nawojowe okrągłe i prostokątne w emalii, średnica do 5 mm, przekrój do 15 mm x 10 mm","test_object_en":"Round and rectangular enamelled winding wires, diameter up to 5 mm, cross-section up to 15 mm x 10 mm","methodology":"Odporność na udar cieplny","methodology_en":"Resistance to thermal shock","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udar cieplny","reference":"Ζ | PN-EN 60851-6:2013-03 | PN-EN 60851-6:1998 | PN-EN 60851-6:1998/A2:2005","norm_bases":["Ζ","PN-EN 60851-6:2013-03","PN-EN 60851-6:1998","PN-EN 60851-6:1998/A2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody nawojowe okrągłe i prostokątne w emalii, średnica do 5 mm, przekrój do 15 mm x 10 mm Odporność na udar cieplny Ζ | PN-EN 60851-6:2013-03 | PN-EN 60851-6:1998 | PN-EN 60851-6:1998/A2:2005 Przewody nawojowe okragle i prostokatne w emalii, srednica do 5 mm, przekroj do 15 mm x 10 mm Odpornosc na udar cieplny Ζ | PN-EN 60851-6:2013-03 | PN-EN 60851-6:1998 | PN-EN 60851-6:1998/A2:2005","categories":["other"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Round and rectangular enamelled winding wires, diameter up to 5 mm, cross-section up to 15 mm x 10 mm Resistance to thermal shock Ζ | PN-EN 60851-6:2013-03 | PN-EN 60851-6:1998 | PN-EN 60851-6:1998/A2:2005"},{"_id":"6a5dc9acf1c10c8ce825a736","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Tworzywa sztuczne, guma, metale","test_object_en":"Plastics, rubber, metals","methodology":"Właściwości mechaniczne przy statycznym rozciąganiu:","methodology_en":"Mechanical properties under static tension:","parameters":[{"name":"wytrzymałość na rozciąganie"},{"name":"wydłużenie przy zerwaniu przed i po starzeniu cieplnym oraz po narażeniu na działanie oleju zakres: siła (10 - 500) N i","range":"(1 - 10) kN"},{"name":"wydłużenie względne","range":"do 1250%"}],"parameters_en":[{"name":"tensile strength"},{"name":"elongation at break before and after thermal ageing and after exposure to oil range: force (10 - 500) N and","range":"(1 - 10) kN"},{"name":"percentage elongation","range":"do 1250%"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości mechaniczne przy statycznym rozciąganiu:\nZakres:\nwytrzymałość na rozciąganie\nwydłużenie przy zerwaniu przed i po starzeniu cieplnym oraz po narażeniu na działanie oleju zakres: siła (10 - 500) N i (1 - 10) kN\nwydłużenie względne do 1250%","reference":"Ζ | PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-3:1998 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 | PN-EN 60811-404:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-EN 60811-1-2:1999 | PN-EN 60811-1-2:1999/A2:2002 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 | PN-ISO 37:2007 | PN-ISO 37:2007/AC1:2008 | PN-E-04160-11:1973 | PN-EN ISO 6892-1:2010 | PN-EN ISO 6892-1:2010/Ap1:2015-02","norm_bases":["Ζ","PN-EN ISO 527-1:2020-01","PN-EN ISO 527-2:2012","PN-EN ISO 527-2:2012/Ap1:2013-09","PN-EN ISO 527-3:1998","PN-EN 60811-501:2012","PN-EN 60811-501:2012/A1:2019-01","PN-EN 60811-501:2012/A2:2024-03","PN-EN 60811-401:2012","PN-EN 60811-401:2012/A1:2018-02","PN-EN 60811-404:2012","PN-EN 60811-1-1:1999","PN-EN 60811-1-1:1999/A1:2002","PN-EN 60811-1-2:1999","PN-EN 60811-1-2:1999/A2:2002","PN-EN 60811-2-1:1999","PN-EN 60811-2-1:1999/A1:2002","PN-ISO 37:2007","PN-ISO 37:2007/AC1:2008","PN-E-04160-11:1973","PN-EN ISO 6892-1:2010","PN-EN ISO 6892-1:2010/Ap1:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, guma, metale Właściwości mechaniczne przy statycznym rozciąganiu:\nZakres:\nwytrzymałość na rozciąganie\nwydłużenie przy zerwaniu przed i po starzeniu cieplnym oraz po narażeniu na działanie oleju zakres: siła (10 - 500) N i (1 - 10) kN\nwydłużenie względne do 1250% Ζ | PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-3:1998 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 | PN-EN 60811-404:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-EN 60811-1-2:1999 | PN-EN 60811-1-2:1999/A2:2002 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 | PN-ISO 37:2007 | PN-ISO 37:2007/AC1:2008 | PN-E-04160-11:1973 | PN-EN ISO 6892-1:2010 | PN-EN ISO 6892-1:2010/Ap1:2015-02 Tworzywa sztuczne, guma, metale Wlasciwosci mechaniczne przy statycznym rozciaganiu:\nZakres:\nwytrzymalosc na rozciaganie\nwydluzenie przy zerwaniu przed i po starzeniu cieplnym oraz po narazeniu na dzialanie oleju zakres: sila (10 - 500) N i (1 - 10) kN\nwydluzenie wzgledne do 1250% Ζ | PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-3:1998 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 | PN-EN 60811-404:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-EN 60811-1-2:1999 | PN-EN 60811-1-2:1999/A2:2002 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 | PN-ISO 37:2007 | PN-ISO 37:2007/AC1:2008 | PN-E-04160-11:1973 | PN-EN ISO 6892-1:2010 | PN-EN ISO 6892-1:2010/Ap1:2015-02","categories":["materials","petro"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plastics, rubber, metals Mechanical properties under static tension: tensile strength elongation at break before and after thermal ageing and after exposure to oil range: force (10 - 500) N and percentage elongation Ζ | PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-3:1998 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 | PN-EN 60811-404:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-EN 60811-1-2:1999 | PN-EN 60811-1-2:1999/A2:2002 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 | PN-ISO 37:2007 | PN-ISO 37:2007/AC1:2008 | PN-E-04160-11:1973 | PN-EN ISO 6892-1:2010 | PN-EN ISO 6892-1:2010/Ap1:2015-02","parameters_zh":[{"name":"抗拉强度"},{"name":"wydłużenie przy zerwaniu przed i po starzeniu cieplnym oraz po narażeniu na działanie oleju zakres: siła (10 - 500) N i","range":"(1 - 10) kN"},{"name":"wydłużenie względne","range":"do 1250%"}],"search_zh":"抗拉强度 Ζ | PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-3:1998 | PN-EN 60811-501:2012 | PN-EN 60811-501:2012/A1:2019-01 | PN-EN 60811-501:2012/A2:2024-03 | PN-EN 60811-401:2012 | PN-EN 60811-401:2012/A1:2018-02 | PN-EN 60811-404:2012 | PN-EN 60811-1-1:1999 | PN-EN 60811-1-1:1999/A1:2002 | PN-EN 60811-1-2:1999 | PN-EN 60811-1-2:1999/A2:2002 | PN-EN 60811-2-1:1999 | PN-EN 60811-2-1:1999/A1:2002 | PN-ISO 37:2007 | PN-ISO 37:2007/AC1:2008 | PN-E-04160-11:1973 | PN-EN ISO 6892-1:2010 | PN-EN ISO 6892-1:2010/Ap1:2015-02"},{"_id":"6a5dc9acf1c10c8ce825a737","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Tworzywa sztuczne, guma, metale","test_object_en":"Plastics, rubber, metals","methodology":"","methodology_en":null,"parameters":[{"name":"wytrzymałość na rozciąganie"},{"name":"wydłużenie przy zerwaniu siła maksymalna 10 kN, wydłużenie względne","range":"do 1250%"}],"parameters_en":[{"name":"tensile strength"},{"name":"elongation at break maximum force 10 kN, percentage elongation","range":"do 1250%"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nwytrzymałość na rozciąganie\nwydłużenie przy zerwaniu siła maksymalna 10 kN, wydłużenie względne do 1250%","reference":"Ζ | PN-EN IEC 60851-3:2024-05 p. 4 | PN-EN 50289-3-2:2002","norm_bases":["Ζ","PN-EN IEC 60851-3:2024-05 p. 4","PN-EN 50289-3-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, guma, metale \nZakres:\nwytrzymałość na rozciąganie\nwydłużenie przy zerwaniu siła maksymalna 10 kN, wydłużenie względne do 1250% Ζ | PN-EN IEC 60851-3:2024-05 p. 4 | PN-EN 50289-3-2:2002 Tworzywa sztuczne, guma, metale \nZakres:\nwytrzymalosc na rozciaganie\nwydluzenie przy zerwaniu sila maksymalna 10 kN, wydluzenie wzgledne do 1250% Ζ | PN-EN IEC 60851-3:2024-05 p. 4 | PN-EN 50289-3-2:2002","categories":["materials"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plastics, rubber, metals tensile strength elongation at break maximum force 10 kN, percentage elongation Ζ | PN-EN IEC 60851-3:2024-05 p. 4 | PN-EN 50289-3-2:2002","parameters_zh":[{"name":"抗拉强度"},{"name":"wydłużenie przy zerwaniu siła maksymalna 10 kN, wydłużenie względne","range":"do 1250%"}],"search_zh":"抗拉强度 Ζ | PN-EN IEC 60851-3:2024-05 p. 4 | PN-EN 50289-3-2:2002"},{"_id":"6a5dc9acf1c10c8ce825a738","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Tworzywa sztuczne, guma","test_object_en":"Plastics, rubber","methodology":"Zapalność metodą wskaźnika tlenowego","methodology_en":"Ignitability by the oxygen index method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zapalność metodą wskaźnika tlenowego","reference":"Ζ | PN-E-04160-56:1990 | PN-EN ISO 4589-2:2006 | PN-EN ISO 4589-2:2006/A1:2006","norm_bases":["Ζ","PN-E-04160-56:1990","PN-EN ISO 4589-2:2006","PN-EN ISO 4589-2:2006/A1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, guma Zapalność metodą wskaźnika tlenowego Ζ | PN-E-04160-56:1990 | PN-EN ISO 4589-2:2006 | PN-EN ISO 4589-2:2006/A1:2006 Tworzywa sztuczne, guma Zapalnosc metoda wskaznika tlenowego Ζ | PN-E-04160-56:1990 | PN-EN ISO 4589-2:2006 | PN-EN ISO 4589-2:2006/A1:2006","categories":["materials"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plastics, rubber Ignitability by the oxygen index method Ζ | PN-E-04160-56:1990 | PN-EN ISO 4589-2:2006 | PN-EN ISO 4589-2:2006/A1:2006"},{"_id":"6a5dc9acf1c10c8ce825a739","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Wytrzymałość elektryczna","methodology_en":"Electric strength","parameters":[{"name":"Zakres","range":"do 75 kV"},{"name":"Próba napięciem przemiennym"}],"parameters_en":[{"name":"Range","range":"do 75 kV"},{"name":"Alternating voltage test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna\nZakres:\nZakres do 75 kV\nPróba napięciem przemiennym","reference":"Ζ | PN-EN 60243-1:2013-12 | PN-EN 60243-1:2002","norm_bases":["Ζ","PN-EN 60243-1:2013-12","PN-EN 60243-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Wytrzymałość elektryczna\nZakres:\nZakres do 75 kV\nPróba napięciem przemiennym Ζ | PN-EN 60243-1:2013-12 | PN-EN 60243-1:2002 Wyroby elektrotechniczne Wytrzymalosc elektryczna\nZakres:\nZakres do 75 kV\nProba napieciem przemiennym Ζ | PN-EN 60243-1:2013-12 | PN-EN 60243-1:2002","categories":["other"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical products Electric strength Range Alternating voltage test Ζ | PN-EN 60243-1:2013-12 | PN-EN 60243-1:2002","parameters_zh":[{"name":"范围","range":"do 75 kV"},{"name":"Próba napięciem przemiennym"}],"search_zh":"电工产品 介电强度 范围 Ζ | PN-EN 60243-1:2013-12 | PN-EN 60243-1:2002","test_object_zh":"电工产品","methodology_zh":"介电强度"},{"_id":"6a5dc9acf1c10c8ce825a73a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Zagrożenie ogniowe:","methodology_en":"Fire hazard:","parameters":[],"parameters_en":[],"technique":"Metody badań znamionowym płomieniem probierczym: 1 kW, 500 W, 50 W,","techniques":["Metody badań znamionowym płomieniem probierczym: 1 kW, 500 W, 50 W,"],"technique_en":"Test methods with a nominal test flame: 1 kW, 500 W, 50 W,","computed":[],"computed_en":[],"activity":"Zagrożenie ogniowe:\nMetody badań znamionowym płomieniem probierczym: 1 kW, 500 W, 50 W,","reference":"Ζ | PN-EN 60695-11-2:2017-11 | PN-EN 60695-11-20:2002 | PN-EN 60695-11-20:2002/A1:2005 | PN-EN 60695-11-20:2015-08 | PN-EN 60695-11-20:2015-08 /AC:2017-01 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014/AC:2017-08 | PN-EN 60695-11-10:2002 | PN-EN 60695-11-10:2002/A1:2005 | PN-EN ISO 9773:2025-03","norm_bases":["Ζ","PN-EN 60695-11-2:2017-11","PN-EN 60695-11-20:2002","PN-EN 60695-11-20:2002/A1:2005","PN-EN 60695-11-20:2015-08","PN-EN 60695-11-20:2015-08 /AC:2017-01","PN-EN 60695-11-10:2014-02","PN-EN 60695-11-10:2014/AC:2017-08","PN-EN 60695-11-10:2002","PN-EN 60695-11-10:2002/A1:2005","PN-EN ISO 9773:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Zagrożenie ogniowe:\nMetody badań znamionowym płomieniem probierczym: 1 kW, 500 W, 50 W, Ζ | PN-EN 60695-11-2:2017-11 | PN-EN 60695-11-20:2002 | PN-EN 60695-11-20:2002/A1:2005 | PN-EN 60695-11-20:2015-08 | PN-EN 60695-11-20:2015-08 /AC:2017-01 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014/AC:2017-08 | PN-EN 60695-11-10:2002 | PN-EN 60695-11-10:2002/A1:2005 | PN-EN ISO 9773:2025-03 Wyroby elektrotechniczne Zagrozenie ogniowe:\nMetody badan znamionowym plomieniem probierczym: 1 kW, 500 W, 50 W, Ζ | PN-EN 60695-11-2:2017-11 | PN-EN 60695-11-20:2002 | PN-EN 60695-11-20:2002/A1:2005 | PN-EN 60695-11-20:2015-08 | PN-EN 60695-11-20:2015-08 /AC:2017-01 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014/AC:2017-08 | PN-EN 60695-11-10:2002 | PN-EN 60695-11-10:2002/A1:2005 | PN-EN ISO 9773:2025-03","categories":["other"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical products Fire hazard: Test methods with a nominal test flame: 1 kW, 500 W, 50 W, Ζ | PN-EN 60695-11-2:2017-11 | PN-EN 60695-11-20:2002 | PN-EN 60695-11-20:2002/A1:2005 | PN-EN 60695-11-20:2015-08 | PN-EN 60695-11-20:2015-08 /AC:2017-01 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014/AC:2017-08 | PN-EN 60695-11-10:2002 | PN-EN 60695-11-10:2002/A1:2005 | PN-EN ISO 9773:2025-03","search_zh":"电工产品 Ζ | PN-EN 60695-11-2:2017-11 | PN-EN 60695-11-20:2002 | PN-EN 60695-11-20:2002/A1:2005 | PN-EN 60695-11-20:2015-08 | PN-EN 60695-11-20:2015-08 /AC:2017-01 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014/AC:2017-08 | PN-EN 60695-11-10:2002 | PN-EN 60695-11-10:2002/A1:2005 | PN-EN ISO 9773:2025-03","test_object_zh":"电工产品"},{"_id":"6a5dc9acf1c10c8ce825a73b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Zagrożenie ogniowe:","methodology_en":"Fire hazard:","parameters":[],"parameters_en":[],"technique":"Metoda badania płomieniem igłowym","techniques":["Metoda badania płomieniem igłowym"],"technique_en":"Needle-flame test method","computed":[],"computed_en":[],"activity":"Zagrożenie ogniowe:\nMetoda badania płomieniem igłowym","reference":"Ζ | PN-EN 60695-11-5:2017-08","norm_bases":["Ζ","PN-EN 60695-11-5:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Zagrożenie ogniowe:\nMetoda badania płomieniem igłowym Ζ | PN-EN 60695-11-5:2017-08 Wyroby elektrotechniczne Zagrozenie ogniowe:\nMetoda badania plomieniem iglowym Ζ | PN-EN 60695-11-5:2017-08","categories":["other"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical products Fire hazard: Needle-flame test method Ζ | PN-EN 60695-11-5:2017-08","search_zh":"电工产品 Ζ | PN-EN 60695-11-5:2017-08","test_object_zh":"电工产品"},{"_id":"6a5dc9acf1c10c8ce825a73c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne","test_object_en":"Electrotechnical products","methodology":"Odporność na gorąco (próba wciskania kulki)","methodology_en":"Resistance to heat (ball pressure test)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na gorąco (próba wciskania kulki)","reference":"Ζ | PN-EN 60695-10-2:2014-10 | PN-EN 60695-10-2:2005","norm_bases":["Ζ","PN-EN 60695-10-2:2014-10","PN-EN 60695-10-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne Odporność na gorąco (próba wciskania kulki) Ζ | PN-EN 60695-10-2:2014-10 | PN-EN 60695-10-2:2005 Wyroby elektrotechniczne Odpornosc na goraco (proba wciskania kulki) Ζ | PN-EN 60695-10-2:2014-10 | PN-EN 60695-10-2:2005","categories":["other"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical products Resistance to heat (ball pressure test) Ζ | PN-EN 60695-10-2:2014-10 | PN-EN 60695-10-2:2005","search_zh":"电工产品 Ζ | PN-EN 60695-10-2:2014-10 | PN-EN 60695-10-2:2005","test_object_zh":"电工产品"},{"_id":"6a5dc9acf1c10c8ce825a73d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na zimno (Próba A), min. temp. (-70±2) °C","methodology_en":"Resistance and endurance to cold (Test A), min. temp. (-70±2) °C","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na zimno (Próba A), min. temp. (-70±2) °C","reference":"Ζ | PN-EN 60068-2-1:2009 | PN-G 50003:2003 | PN-G 50006:1997","norm_bases":["Ζ","PN-EN 60068-2-1:2009","PN-G 50003:2003","PN-G 50006:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na zimno (Próba A), min. temp. (-70±2) °C Ζ | PN-EN 60068-2-1:2009 | PN-G 50003:2003 | PN-G 50006:1997 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na zimno (Proba A), min. temp. (-70±2) °C Ζ | PN-EN 60068-2-1:2009 | PN-G 50003:2003 | PN-G 50006:1997","categories":["electronics"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to cold (Test A), min. temp. (-70±2) °C Ζ | PN-EN 60068-2-1:2009 | PN-G 50003:2003 | PN-G 50006:1997","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN 60068-2-1:2009 | PN-G 50003:2003 | PN-G 50006:1997","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a73e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na suche gorąco (Próba B) do temp. (180±2) °C","methodology_en":"Resistance and endurance to dry heat (Test B) up to temp. (180±2) °C","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na suche gorąco (Próba B) do temp. (180±2) °C","reference":"Ζ | PN-EN 60068-2-2:2009 | PN-G 50003:2003 | PN-G 50006:1997","norm_bases":["Ζ","PN-EN 60068-2-2:2009","PN-G 50003:2003","PN-G 50006:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na suche gorąco (Próba B) do temp. (180±2) °C Ζ | PN-EN 60068-2-2:2009 | PN-G 50003:2003 | PN-G 50006:1997 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na suche goraco (Proba B) do temp. (180±2) °C Ζ | PN-EN 60068-2-2:2009 | PN-G 50003:2003 | PN-G 50006:1997","categories":["electronics"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to dry heat (Test B) up to temp. (180±2) °C Ζ | PN-EN 60068-2-2:2009 | PN-G 50003:2003 | PN-G 50006:1997","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN 60068-2-2:2009 | PN-G 50003:2003 | PN-G 50006:1997","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a73f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na wilgotne gorąco stałe (Próba Cab) w zakresie temperatury do (95±2) °C i wilgotności względnej do (93±3)%","methodology_en":"Resistance and endurance to steady-state damp heat (Test Cab) in the temperature range up to (95±2) °C and relative humidity up to (93±3)%","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco stałe (Próba Cab) w zakresie temperatury do (95±2) °C i wilgotności względnej do (93±3)%","reference":"Ζ | PN-EN 60068-2-78:2013-11 | PN-EN 60068-2-78:2007 | PN-G 50003:2003 | PN-G 50006:1997","norm_bases":["Ζ","PN-EN 60068-2-78:2013-11","PN-EN 60068-2-78:2007","PN-G 50003:2003","PN-G 50006:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na wilgotne gorąco stałe (Próba Cab) w zakresie temperatury do (95±2) °C i wilgotności względnej do (93±3)% Ζ | PN-EN 60068-2-78:2013-11 | PN-EN 60068-2-78:2007 | PN-G 50003:2003 | PN-G 50006:1997 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na wilgotne goraco stale (Proba Cab) w zakresie temperatury do (95±2) °C i wilgotnosci wzglednej do (93±3)% Ζ | PN-EN 60068-2-78:2013-11 | PN-EN 60068-2-78:2007 | PN-G 50003:2003 | PN-G 50006:1997","categories":["electronics"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to steady-state damp heat (Test Cab) in the temperature range up to (95±2) °C and relative humidity up to (93±3)% Ζ | PN-EN 60068-2-78:2013-11 | PN-EN 60068-2-78:2007 | PN-G 50003:2003 | PN-G 50006:1997","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN 60068-2-78:2013-11 | PN-EN 60068-2-78:2007 | PN-G 50003:2003 | PN-G 50006:1997","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a740","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na wilgotne gorąco cykliczne (Próba Db) w zakresie temperatury do (55±2) °C i wilgotności względnej do (95±3)%","methodology_en":"Resistance and endurance to cyclic damp heat (Test Db) in the temperature range up to (55±2) °C and relative humidity up to (95±3)%","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wilgotne gorąco cykliczne (Próba Db) w zakresie temperatury do (55±2) °C i wilgotności względnej do (95±3)%","reference":"Ζ | PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1","norm_bases":["Ζ","PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na wilgotne gorąco cykliczne (Próba Db) w zakresie temperatury do (55±2) °C i wilgotności względnej do (95±3)% Ζ | PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na wilgotne goraco cykliczne (Proba Db) w zakresie temperatury do (55±2) °C i wilgotnosci wzglednej do (95±3)% Ζ | PN-EN 60068-2-30:2008 z wyl. p. 7.3.3, wariant 1","categories":["electronics"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to cyclic damp heat (Test Db) in the temperature range up to (55±2) °C and relative humidity up to (95±3)% Ζ | PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN 60068-2-30:2008 z wył. p. 7.3.3, wariant 1","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a741","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Próba N: Zmiany temperatury","methodology_en":"Test N: Change of temperature","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba N: Zmiany temperatury","reference":"Ζ | PN-EN IEC 60068-2-14:2024-04","norm_bases":["Ζ","PN-EN IEC 60068-2-14:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Próba N: Zmiany temperatury Ζ | PN-EN IEC 60068-2-14:2024-04 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Proba N: Zmiany temperatury Ζ | PN-EN IEC 60068-2-14:2024-04","categories":["electronics"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test N: Change of temperature Ζ | PN-EN IEC 60068-2-14:2024-04","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN IEC 60068-2-14:2024-04","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a742","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Próby kombinowane, temperatura lub temperatura i wilgotność w połączeniu z niskim ciśnieniem atmosferycznym w","methodology_en":"Combined tests, temperature or temperature and humidity in combination with low air pressure in","parameters":[{"name":"zakresie","range":"(20 – 950) mBar"}],"parameters_en":[{"name":"range","range":"(20 – 950) mBar"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próby kombinowane, temperatura lub temperatura i wilgotność w połączeniu z niskim ciśnieniem atmosferycznym w\nzakresie (20 – 950) mBar","reference":"Ζ | PN-EN 60068-2-39:2016-04 | PN-EN 60068-2-39:2016-04 /Ap1:2019-04","norm_bases":["Ζ","PN-EN 60068-2-39:2016-04","PN-EN 60068-2-39:2016-04 /Ap1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Próby kombinowane, temperatura lub temperatura i wilgotność w połączeniu z niskim ciśnieniem atmosferycznym w\nzakresie (20 – 950) mBar Ζ | PN-EN 60068-2-39:2016-04 | PN-EN 60068-2-39:2016-04 /Ap1:2019-04 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Proby kombinowane, temperatura lub temperatura i wilgotnosc w polaczeniu z niskim cisnieniem atmosferycznym w\nzakresie (20 – 950) mBar Ζ | PN-EN 60068-2-39:2016-04 | PN-EN 60068-2-39:2016-04 /Ap1:2019-04","categories":["electronics"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Combined tests, temperature or temperature and humidity in combination with low air pressure in range Ζ | PN-EN 60068-2-39:2016-04 | PN-EN 60068-2-39:2016-04 /Ap1:2019-04","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 范围 Ζ | PN-EN 60068-2-39:2016-04 | PN-EN 60068-2-39:2016-04 /Ap1:2019-04","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。","parameters_zh":[{"name":"范围","range":"(20 – 950) mBar"}]},{"_id":"6a5dc9acf1c10c8ce825a743","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Próba Z/AM: próba kombinowana zimno/ niskie ciśnienie atmosferyczne w zakresie: (20 – 950) mBar","methodology_en":"Test Z/AM: combined cold/ low air pressure test in the range: (20 – 950) mBar","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Z/AM: próba kombinowana zimno/ niskie ciśnienie atmosferyczne w zakresie: (20 – 950) mBar","reference":"Ζ | PN-EN 60068-2-40:2002","norm_bases":["Ζ","PN-EN 60068-2-40:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Próba Z/AM: próba kombinowana zimno/ niskie ciśnienie atmosferyczne w zakresie: (20 – 950) mBar Ζ | PN-EN 60068-2-40:2002 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Proba Z/AM: proba kombinowana zimno/ niskie cisnienie atmosferyczne w zakresie: (20 – 950) mBar Ζ | PN-EN 60068-2-40:2002","categories":["electronics"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test Z/AM: combined cold/ low air pressure test in the range: (20 – 950) mBar Ζ | PN-EN 60068-2-40:2002","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN 60068-2-40:2002","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a744","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Próba Z/BM: próba kombinowana suche gorąco/ niskie ciśnienie atmosferyczne w","methodology_en":"Test Z/BM: combined dry heat/ low air pressure test in","parameters":[{"name":"zakresie","range":"(20 – 950) mBar"}],"parameters_en":[{"name":"range","range":"(20 – 950) mBar"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba Z/BM: próba kombinowana suche gorąco/ niskie ciśnienie atmosferyczne w\nzakresie (20 – 950) mBar","reference":"Ζ | PN-EN 60068-2-41:2002","norm_bases":["Ζ","PN-EN 60068-2-41:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Próba Z/BM: próba kombinowana suche gorąco/ niskie ciśnienie atmosferyczne w\nzakresie (20 – 950) mBar Ζ | PN-EN 60068-2-41:2002 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Proba Z/BM: proba kombinowana suche goraco/ niskie cisnienie atmosferyczne w\nzakresie (20 – 950) mBar Ζ | PN-EN 60068-2-41:2002","categories":["electronics"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test Z/BM: combined dry heat/ low air pressure test in range Ζ | PN-EN 60068-2-41:2002","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 范围 Ζ | PN-EN 60068-2-41:2002","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。","parameters_zh":[{"name":"范围","range":"(20 – 950) mBar"}]},{"_id":"6a5dc9acf1c10c8ce825a745","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Próba M: niskie ciśnienie atmosferyczne (podciśnienie) w zakresie: (11 – 99) kPa (110 – 990) mbar","methodology_en":"Test M: low air pressure (underpressure) in the range: (11 – 99) kPa (110 – 990) mbar","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba M: niskie ciśnienie atmosferyczne (podciśnienie) w zakresie: (11 – 99) kPa (110 – 990) mbar","reference":"Ζ | PN-EN IEC 60068-2-13:2021-11","norm_bases":["Ζ","PN-EN IEC 60068-2-13:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Próba M: niskie ciśnienie atmosferyczne (podciśnienie) w zakresie: (11 – 99) kPa (110 – 990) mbar Ζ | PN-EN IEC 60068-2-13:2021-11 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Proba M: niskie cisnienie atmosferyczne (podcisnienie) w zakresie: (11 – 99) kPa (110 – 990) mbar Ζ | PN-EN IEC 60068-2-13:2021-11","categories":["electronics"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Test M: low air pressure (underpressure) in the range: (11 – 99) kPa (110 – 990) mbar Ζ | PN-EN IEC 60068-2-13:2021-11","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 Ζ | PN-EN IEC 60068-2-13:2021-11","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a746","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na udary (Próba Ea) [shock]","methodology_en":"Resistance and endurance to shock (Test Ea) [shock]","parameters":[{"name":"Maksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku"},{"name":"narażenia)","range":"do 264 g, z wyłączeniem"},{"name":"próby dla 2500 [m/s2]/1 [ms]"},{"name":"Masa obiektu","range":"do 500 kg"},{"name":"Amplituda szczytowa przemieszczenia: do ±38,1 mm"}],"parameters_en":[{"name":"Maximum acceleration (depending on the mass of the tested object and the direction"},{"name":"exposure)","range":"do 264 g, z wyłączeniem"},{"name":"tests for 2500 [m/s2]/1 [ms]"},{"name":"Mass of the object","range":"do 500 kg"},{"name":"Peak displacement amplitude: up to ±38,1 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na udary (Próba Ea) [shock]\nZakres:\nMaksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku\nnarażenia) do 264 g, z wyłączeniem\npróby dla 2500 [m/s2]/1 [ms]\nMasa obiektu do 500 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm","reference":"Ζ | PN-EN 60068-2-27:2009 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 | PN-EN 60255-21-2:2000","norm_bases":["Ζ","PN-EN 60068-2-27:2009","PN-EN 50125-3:2003 p. 4.13","PN-EN 50125-3:2003/AC:2010","PN-EN 60255-21-2:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na udary (Próba Ea) [shock]\nZakres:\nMaksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku\nnarażenia) do 264 g, z wyłączeniem\npróby dla 2500 [m/s2]/1 [ms]\nMasa obiektu do 500 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm Ζ | PN-EN 60068-2-27:2009 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 | PN-EN 60255-21-2:2000 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na udary (Proba Ea) [shock]\nZakres:\nMaksymalne przyspieszenie (w zaleznosci od masy badanego obiektu i kierunku\nnarazenia) do 264 g, z wylaczeniem\nproby dla 2500 [m/s2]/1 [ms]\nMasa obiektu do 500 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm Ζ | PN-EN 60068-2-27:2009 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 | PN-EN 60255-21-2:2000","categories":["electronics"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to shock (Test Ea) [shock] Maximum acceleration (depending on the mass of the tested object and the direction exposure) tests for 2500 [m/s2]/1 [ms] Mass of the object Peak displacement amplitude: up to ±38,1 mm Ζ | PN-EN 60068-2-27:2009 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 | PN-EN 60255-21-2:2000","search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 最大加速度（取决于受检对象的质量与 试验方向） 对象质量 位移峰值幅度：至 ±38,1 mm Ζ | PN-EN 60068-2-27:2009 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 | PN-EN 60255-21-2:2000","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。","parameters_zh":[{"name":"最大加速度（取决于受检对象的质量与"},{"name":"试验方向）","range":"do 264 g, z wyłączeniem"},{"name":"próby dla 2500 [m/s2]/1 [ms]"},{"name":"对象质量","range":"do 500 kg"},{"name":"位移峰值幅度：至 ±38,1 mm"}]},{"_id":"6a5dc9acf1c10c8ce825a747","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na wibracje (Próba Fc) (sinusoidalne) [vibration]","methodology_en":"Resistance and endurance to vibration (Test Fc) (sinusoidal) [vibration]","parameters":[{"name":"Zakres częstotliwości","range":"(5 - 2000) Hz,"},{"name":"Maksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku"},{"name":"narażenia)","range":"do 13 g"},{"name":"Masa obiektu","range":"do 500 kg"},{"name":"Amplituda szczytowa przemieszczenia: do ±38,1 mm"}],"parameters_en":[{"name":"Frequency range","range":"(5 - 2000) Hz,"},{"name":"Maximum acceleration (depending on the mass of the tested object and the direction"},{"name":"exposure)","range":"do 13 g"},{"name":"Mass of the object","range":"do 500 kg"},{"name":"Peak displacement amplitude: up to ±38,1 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wibracje (Próba Fc) (sinusoidalne) [vibration]\nZakres:\nZakres częstotliwości (5 - 2000) Hz,\nMaksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku\nnarażenia) do 13 g\nMasa obiektu do 500 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm","reference":"Ζ | PN-EN 60068-2-6:2008 | PN-EN 60255-21-1:1999 | PN-EN IEC 60598-1:2025-04 p. 7.20.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 | PN-G-50006:1997","norm_bases":["Ζ","PN-EN 60068-2-6:2008","PN-EN 60255-21-1:1999","PN-EN IEC 60598-1:2025-04 p. 7.20.1","PN-EN IEC 60598-1:2025-04/A11:2025-08","PN-G-50006:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na wibracje (Próba Fc) (sinusoidalne) [vibration]\nZakres:\nZakres częstotliwości (5 - 2000) Hz,\nMaksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku\nnarażenia) do 13 g\nMasa obiektu do 500 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm Ζ | PN-EN 60068-2-6:2008 | PN-EN 60255-21-1:1999 | PN-EN IEC 60598-1:2025-04 p. 7.20.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 | PN-G-50006:1997 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na wibracje (Proba Fc) (sinusoidalne) [vibration]\nZakres:\nZakres czestotliwosci (5 - 2000) Hz,\nMaksymalne przyspieszenie (w zaleznosci od masy badanego obiektu i kierunku\nnarazenia) do 13 g\nMasa obiektu do 500 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm Ζ | PN-EN 60068-2-6:2008 | PN-EN 60255-21-1:1999 | PN-EN IEC 60598-1:2025-04 p. 7.20.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 | PN-G-50006:1997","categories":["electronics"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to vibration (Test Fc) (sinusoidal) [vibration] Frequency range Maximum acceleration (depending on the mass of the tested object and the direction exposure) Mass of the object Peak displacement amplitude: up to ±38,1 mm Ζ | PN-EN 60068-2-6:2008 | PN-EN 60255-21-1:1999 | PN-EN IEC 60598-1:2025-04 p. 7.20.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 | PN-G-50006:1997","parameters_zh":[{"name":"频率范围","range":"(5 - 2000) Hz,"},{"name":"最大加速度（取决于受检对象的质量与"},{"name":"试验方向）","range":"do 13 g"},{"name":"对象质量","range":"do 500 kg"},{"name":"位移峰值幅度：至 ±38,1 mm"}],"search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 频率范围 最大加速度（取决于受检对象的质量与 试验方向） 对象质量 位移峰值幅度：至 ±38,1 mm Ζ | PN-EN 60068-2-6:2008 | PN-EN 60255-21-1:1999 | PN-EN IEC 60598-1:2025-04 p. 7.20.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 | PN-G-50006:1997","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a748","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego).","test_object_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system).","methodology":"Odporność i wytrzymałość na wibracje przypadkowe szerokopasmowe (Próba Fh)","methodology_en":"Resistance and endurance to broadband random vibration (Test Fh)","parameters":[{"name":"Zakres częstotliwości","range":"(5 - 2000) Hz,"},{"name":"Maksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku"},{"name":"narażenia)","range":"do 100 g,"},{"name":"Masa obiektu","range":"do 800 kg"},{"name":"Amplituda szczytowa przemieszczenia: do ±38,1 mm"}],"parameters_en":[{"name":"Frequency range","range":"(5 - 2000) Hz,"},{"name":"Maximum acceleration (depending on the mass of the tested object and the direction"},{"name":"exposure)","range":"do 100 g,"},{"name":"Mass of the object","range":"do 800 kg"},{"name":"Peak displacement amplitude: up to ±38,1 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wibracje przypadkowe szerokopasmowe (Próba Fh)\nZakres:\nZakres częstotliwości (5 - 2000) Hz,\nMaksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku\nnarażenia) do 100 g,\nMasa obiektu do 800 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm","reference":"Ζ | PN-EN 60068-2-64:2008 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010","norm_bases":["Ζ","PN-EN 60068-2-64:2008","PN-EN 50125-3:2003 p. 4.13","PN-EN 50125-3:2003/AC:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoły (z ograniczeniem wymiarów geometrycznych i masy odpowiednio do parametrów komór klimatycznych/systemu wibracyjnego). Odporność i wytrzymałość na wibracje przypadkowe szerokopasmowe (Próba Fh)\nZakres:\nZakres częstotliwości (5 - 2000) Hz,\nMaksymalne przyspieszenie (w zależności od masy badanego obiektu i kierunku\nnarażenia) do 100 g,\nMasa obiektu do 800 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm Ζ | PN-EN 60068-2-64:2008 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010 Wyroby elektrotechniczne, telekomunikacyjne i elektroniczne oraz podzespoly (z ograniczeniem wymiarow geometrycznych i masy odpowiednio do parametrow komor klimatycznych/systemu wibracyjnego). Odpornosc i wytrzymalosc na wibracje przypadkowe szerokopasmowe (Proba Fh)\nZakres:\nZakres czestotliwosci (5 - 2000) Hz,\nMaksymalne przyspieszenie (w zaleznosci od masy badanego obiektu i kierunku\nnarazenia) do 100 g,\nMasa obiektu do 800 kg\nAmplituda szczytowa przemieszczenia: do ±38,1 mm Ζ | PN-EN 60068-2-64:2008 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010","categories":["electronics"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrotechnical, telecommunications and electronic products and components (with a limitation of geometric dimensions and mass according to the parameters of the climatic chambers/vibration system). Resistance and endurance to broadband random vibration (Test Fh) Frequency range Maximum acceleration (depending on the mass of the tested object and the direction exposure) Mass of the object Peak displacement amplitude: up to ±38,1 mm Ζ | PN-EN 60068-2-64:2008 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010","parameters_zh":[{"name":"频率范围","range":"(5 - 2000) Hz,"},{"name":"最大加速度（取决于受检对象的质量与"},{"name":"试验方向）","range":"do 100 g,"},{"name":"对象质量","range":"do 800 kg"},{"name":"位移峰值幅度：至 ±38,1 mm"}],"search_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。 频率范围 最大加速度（取决于受检对象的质量与 试验方向） 对象质量 位移峰值幅度：至 ±38,1 mm Ζ | PN-EN 60068-2-64:2008 | PN-EN 50125-3:2003 p. 4.13 | PN-EN 50125-3:2003/AC:2010","test_object_zh":"电工、电信与电子产品及组件（几何尺寸与质量受气候试验箱/振动系统参数限制）。"},{"_id":"6a5dc9acf1c10c8ce825a749","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wymiary dla obiektów dł./szer./wys. 750 mm/750 mm /600 mm (dla badania IP5X i IP6X), Wymiary dla przestrzeni roboczej średnica/ wysokość 1530 mm/ 1250 mm (dla badania IPX7 i IPX8)","test_object_en":"Dimensions for objects l./w./h. 750 mm/750 mm /600 mm (for IP5X and IP6X testing), Dimensions for the working space diameter/ height 1530 mm/ 1250 mm (for IPX7 and IPX8 testing)","methodology":"Badanie / sprawdzenie stopnia ochrony IP:","methodology_en":"Testing / verification of the IP degree of protection:","parameters":[{"name":"IP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 do IPX8 ochrona przed wodą; IPX9k ochrona przed wodą;"}],"parameters_en":[{"name":"IP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 to IPX8 protection against water; IPX9k protection against water;"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie / sprawdzenie stopnia ochrony IP:\nIP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 do IPX8 ochrona przed wodą; IPX9k ochrona przed wodą;","reference":"Ζ | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | ISO 20653:2013","norm_bases":["Ζ","PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","PN-EN 60529:2003/AC:2017-12","PN-EN 60529:2003/AC:2020-01","PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","PN-EN 60529:2003/AC:2017-12","PN-EN 60529:2003/AC:2020-01","ISO 20653:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wymiary dla obiektów dł./szer./wys. 750 mm/750 mm /600 mm (dla badania IP5X i IP6X), Wymiary dla przestrzeni roboczej średnica/ wysokość 1530 mm/ 1250 mm (dla badania IPX7 i IPX8) Badanie / sprawdzenie stopnia ochrony IP:\nIP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 do IPX8 ochrona przed wodą; IPX9k ochrona przed wodą; Ζ | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | ISO 20653:2013 Wymiary dla obiektow dl./szer./wys. 750 mm/750 mm /600 mm (dla badania IP5X i IP6X), Wymiary dla przestrzeni roboczej srednica/ wysokosc 1530 mm/ 1250 mm (dla badania IPX7 i IPX8) Badanie / sprawdzenie stopnia ochrony IP:\nIP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 do IPX8 ochrona przed woda; IPX9k ochrona przed woda; Ζ | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | ISO 20653:2013","categories":["other"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dimensions for objects l./w./h. 750 mm/750 mm /600 mm (for IP5X and IP6X testing), Dimensions for the working space diameter/ height 1530 mm/ 1250 mm (for IPX7 and IPX8 testing) Testing / verification of the IP degree of protection: IP1X, IP2X, IP3X, IP4X, IP5X, IP6X; IPX1 to IPX8 protection against water; IPX9k protection against water; Ζ | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/AC:2020-01 | ISO 20653:2013"},{"_id":"6a5dc9acf1c10c8ce825a74a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyposażenie taboru kolejowego","test_object_en":"Rolling stock equipment","methodology":"Odporność i wytrzymałość na udary (Próba Ea) [shock]","methodology_en":"Resistance and endurance to shock (Test Ea) [shock]","parameters":[{"name":"Masa obiektu","range":"do 500 kg"}],"parameters_en":[{"name":"Mass of the object","range":"do 500 kg"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na udary (Próba Ea) [shock]\nMasa obiektu do 500 kg","reference":"Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","norm_bases":["Ζ","PN-EN 61373:2011","PN-EN 61373:2011/AC:2017-11","PN-EN 50155:2022-05 p. 13.4.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie taboru kolejowego Odporność i wytrzymałość na udary (Próba Ea) [shock]\nMasa obiektu do 500 kg Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10 Wyposazenie taboru kolejowego Odpornosc i wytrzymalosc na udary (Proba Ea) [shock]\nMasa obiektu do 500 kg Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","categories":["other"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rolling stock equipment Resistance and endurance to shock (Test Ea) [shock] Mass of the object Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","parameters_zh":[{"name":"对象质量","range":"do 500 kg"}],"search_zh":"铁道车辆装备 对象质量 Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","test_object_zh":"铁道车辆装备"},{"_id":"6a5dc9acf1c10c8ce825a74b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyposażenie taboru kolejowego","test_object_en":"Rolling stock equipment","methodology":"Odporność i wytrzymałość na wibracje przypadkowe (Próba Fh)","methodology_en":"Resistance and endurance to random vibration (Test Fh)","parameters":[{"name":"Masa obiektu","range":"do 500 kg"}],"parameters_en":[{"name":"Mass of the object","range":"do 500 kg"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność i wytrzymałość na wibracje przypadkowe (Próba Fh)\nMasa obiektu do 500 kg","reference":"Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","norm_bases":["Ζ","PN-EN 61373:2011","PN-EN 61373:2011/AC:2017-11","PN-EN 50155:2022-05 p. 13.4.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie taboru kolejowego Odporność i wytrzymałość na wibracje przypadkowe (Próba Fh)\nMasa obiektu do 500 kg Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10 Wyposazenie taboru kolejowego Odpornosc i wytrzymalosc na wibracje przypadkowe (Proba Fh)\nMasa obiektu do 500 kg Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","categories":["other"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rolling stock equipment Resistance and endurance to random vibration (Test Fh) Mass of the object Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","parameters_zh":[{"name":"对象质量","range":"do 500 kg"}],"search_zh":"铁道车辆装备 对象质量 Ζ | PN-EN 61373:2011 | PN-EN 61373:2011/AC:2017-11 | PN-EN 50155:2022-05 p. 13.4.10","test_object_zh":"铁道车辆装备"},{"_id":"6a5dc9acf1c10c8ce825a74c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyposażenie taboru kolejowego","test_object_en":"Rolling stock equipment","methodology":"Odporność na zimno","methodology_en":"Cold resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zimno","reference":"Ζ | PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6 | PN-EN 60068-2-1:2009","norm_bases":["Ζ","PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6","PN-EN 60068-2-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie taboru kolejowego Odporność na zimno Ζ | PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6 | PN-EN 60068-2-1:2009 Wyposazenie taboru kolejowego Odpornosc na zimno Ζ | PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6 | PN-EN 60068-2-1:2009","categories":["other"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rolling stock equipment Cold resistance Ζ | PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6 | PN-EN 60068-2-1:2009","search_zh":"铁道车辆装备 Ζ | PN-EN 50155:2022-05 p. 13.4.4 i 13.4.6 | PN-EN 60068-2-1:2009","test_object_zh":"铁道车辆装备"},{"_id":"6a5dc9acf1c10c8ce825a74d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyposażenie taboru kolejowego","test_object_en":"Rolling stock equipment","methodology":"Odporność na suche gorąco","methodology_en":"Resistance to dry heat","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na suche gorąco","reference":"Ζ | PN-EN 50155:2022-05 p. 13.4.5 | PN-EN 60068-2-2:2009","norm_bases":["Ζ","PN-EN 50155:2022-05 p. 13.4.5","PN-EN 60068-2-2:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie taboru kolejowego Odporność na suche gorąco Ζ | PN-EN 50155:2022-05 p. 13.4.5 | PN-EN 60068-2-2:2009 Wyposazenie taboru kolejowego Odpornosc na suche goraco Ζ | PN-EN 50155:2022-05 p. 13.4.5 | PN-EN 60068-2-2:2009","categories":["other"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rolling stock equipment Resistance to dry heat Ζ | PN-EN 50155:2022-05 p. 13.4.5 | PN-EN 60068-2-2:2009","search_zh":"铁道车辆装备 Ζ | PN-EN 50155:2022-05 p. 13.4.5 | PN-EN 60068-2-2:2009","test_object_zh":"铁道车辆装备"},{"_id":"6a5dc9acf1c10c8ce825a74e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyposażenie taboru kolejowego","test_object_en":"Rolling stock equipment","methodology":"Odporność na wilgotne gorąco","methodology_en":"Damp heat resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wilgotne gorąco","reference":"Ζ | PN-EN 50155:2022-05 p. 13.4.8 | PN-EN 60068-2-30:2008","norm_bases":["Ζ","PN-EN 50155:2022-05 p. 13.4.8","PN-EN 60068-2-30:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie taboru kolejowego Odporność na wilgotne gorąco Ζ | PN-EN 50155:2022-05 p. 13.4.8 | PN-EN 60068-2-30:2008 Wyposazenie taboru kolejowego Odpornosc na wilgotne goraco Ζ | PN-EN 50155:2022-05 p. 13.4.8 | PN-EN 60068-2-30:2008","categories":["other"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rolling stock equipment Damp heat resistance Ζ | PN-EN 50155:2022-05 p. 13.4.8 | PN-EN 60068-2-30:2008","search_zh":"铁道车辆装备 Ζ | PN-EN 50155:2022-05 p. 13.4.8 | PN-EN 60068-2-30:2008","test_object_zh":"铁道车辆装备"},{"_id":"6a5dc9acf1c10c8ce825a74f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyposażenie taboru kolejowego","test_object_en":"Rolling stock equipment","methodology":"Badanie izolacji","methodology_en":"Insulation testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie izolacji","reference":"Ζ | PN-EN 50155:2022-05 p. 13.4.7","norm_bases":["Ζ","PN-EN 50155:2022-05 p. 13.4.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie taboru kolejowego Badanie izolacji Ζ | PN-EN 50155:2022-05 p. 13.4.7 Wyposazenie taboru kolejowego Badanie izolacji Ζ | PN-EN 50155:2022-05 p. 13.4.7","categories":["construction"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rolling stock equipment Insulation testing Ζ | PN-EN 50155:2022-05 p. 13.4.7","search_zh":"铁道车辆装备 Ζ | PN-EN 50155:2022-05 p. 13.4.7","test_object_zh":"铁道车辆装备"},{"_id":"6a5dc9acf1c10c8ce825a750","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Sprawdzenie odporności obudowy na uderzenia mechaniczne, Próby młotami: Ehb","methodology_en":"Verification of the resistance of the enclosure to mechanical impacts, Hammer tests: Ehb","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie odporności obudowy na uderzenia mechaniczne, Próby młotami: Ehb","reference":"Ζ | PN-EN 60068-2-75:2015-01 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60598-1:2025-04 p. 7.13.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08","norm_bases":["Ζ","PN-EN 60068-2-75:2015-01","PN-EN IEC 60335-1:2024-04 p. 21.1","PN-EN IEC 60598-1:2025-04 p. 7.13.1","PN-EN IEC 60598-1:2025-04/A11:2025-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Sprawdzenie odporności obudowy na uderzenia mechaniczne, Próby młotami: Ehb Ζ | PN-EN 60068-2-75:2015-01 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60598-1:2025-04 p. 7.13.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Sprawdzenie odpornosci obudowy na uderzenia mechaniczne, Proby mlotami: Ehb Ζ | PN-EN 60068-2-75:2015-01 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60598-1:2025-04 p. 7.13.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08","categories":["electronics"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Verification of the resistance of the enclosure to mechanical impacts, Hammer tests: Ehb Ζ | PN-EN 60068-2-75:2015-01 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60598-1:2025-04 p. 7.13.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08","search_zh":"电气、电信与电子产品及设备 Ζ | PN-EN 60068-2-75:2015-01 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60598-1:2025-04 p. 7.13.1 | PN-EN IEC 60598-1:2025-04/A11:2025-08","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a751","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Sprawdzenie stopnia ochrony przed uderzeniami mechanicznymi (kod IK) Próby młotami: Ehb","methodology_en":"Verification of the degree of protection against mechanical impacts (IK code) Hammer tests: Ehb","parameters":[{"name":"Zakres","range":"do IK 06"}],"parameters_en":[{"name":"Range","range":"do IK 06"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie stopnia ochrony przed uderzeniami mechanicznymi (kod IK) Próby młotami: Ehb\nZakres do IK 06","reference":"Ζ | PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 62262:2003 | PN-EN 62262:2003/Ap1:2022-01 | PN-EN 62262:2003/A1:2022-06","norm_bases":["Ζ","PN-EN 50102:2001","PN-EN 50102:2001/AC:2011","PN-EN 62262:2003","PN-EN 62262:2003/Ap1:2022-01","PN-EN 62262:2003/A1:2022-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Sprawdzenie stopnia ochrony przed uderzeniami mechanicznymi (kod IK) Próby młotami: Ehb\nZakres do IK 06 Ζ | PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 62262:2003 | PN-EN 62262:2003/Ap1:2022-01 | PN-EN 62262:2003/A1:2022-06 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Sprawdzenie stopnia ochrony przed uderzeniami mechanicznymi (kod IK) Proby mlotami: Ehb\nZakres do IK 06 Ζ | PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 62262:2003 | PN-EN 62262:2003/Ap1:2022-01 | PN-EN 62262:2003/A1:2022-06","categories":["electronics"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Verification of the degree of protection against mechanical impacts (IK code) Hammer tests: Ehb Range Ζ | PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 62262:2003 | PN-EN 62262:2003/Ap1:2022-01 | PN-EN 62262:2003/A1:2022-06","parameters_zh":[{"name":"范围","range":"do IK 06"}],"search_zh":"电气、电信与电子产品及设备 范围 Ζ | PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 62262:2003 | PN-EN 62262:2003/Ap1:2022-01 | PN-EN 62262:2003/A1:2022-06","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a752","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Zanurzenie w wodzie","methodology_en":"Immersion in water","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zanurzenie w wodzie","reference":"Ζ | PN-EN 50604-1:2017-02, p. 8.3 | PN-EN 50604-1:2017-02/A1:2022-05","norm_bases":["Ζ","PN-EN 50604-1:2017-02, p. 8.3","PN-EN 50604-1:2017-02/A1:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Zanurzenie w wodzie Ζ | PN-EN 50604-1:2017-02, p. 8.3 | PN-EN 50604-1:2017-02/A1:2022-05 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Zanurzenie w wodzie Ζ | PN-EN 50604-1:2017-02, p. 8.3 | PN-EN 50604-1:2017-02/A1:2022-05","categories":["electronics"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Immersion in water Ζ | PN-EN 50604-1:2017-02, p. 8.3 | PN-EN 50604-1:2017-02/A1:2022-05","search_zh":"电气、电信与电子产品及设备 Ζ | PN-EN 50604-1:2017-02, p. 8.3 | PN-EN 50604-1:2017-02/A1:2022-05","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a753","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na obniżone ciśnienie [altitude simulation]","methodology_en":"Resistance to reduced pressure [altitude simulation]","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obniżone ciśnienie [altitude simulation]","reference":"Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)","norm_bases":["Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na obniżone ciśnienie [altitude simulation] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1) Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na obnizone cisnienie [altitude simulation] Ζ Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)","categories":["electronics"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Resistance to reduced pressure [altitude simulation] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)","search_zh":"电气、电信与电子产品及设备 Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.1 (Test T.1)","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a754","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na zmiany temperatury","methodology_en":"Resistance to temperature changes","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmiany temperatury","reference":"Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)","norm_bases":["Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na zmiany temperatury Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2) Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na zmiany temperatury Ζ Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)","categories":["electronics"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Resistance to temperature changes Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)","search_zh":"电气、电信与电子产品及设备 耐温度变化性 Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.2 (Test T.2)","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"耐温度变化性"},{"_id":"6a5dc9acf1c10c8ce825a755","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na wibracje [vibration]","methodology_en":"Vibration resistance [vibration]","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wibracje [vibration]","reference":"Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)","norm_bases":["Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na wibracje [vibration] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3) Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na wibracje [vibration] Ζ Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)","categories":["electronics"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Vibration resistance [vibration] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)","search_zh":"电气、电信与电子产品及设备 Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.3 (Test T.3)","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a756","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na udary [shock]","methodology_en":"Resistance to shocks [shock]","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary [shock]","reference":"Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)","norm_bases":["Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na udary [shock] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4) Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na udary [shock] Ζ Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)","categories":["electronics"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Resistance to shocks [shock] Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)","search_zh":"电气、电信与电子产品及设备 Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.4 (Test T.4)","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a757","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na zwarcie zewnętrzne","methodology_en":"Resistance to external short circuit","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zwarcie zewnętrzne","reference":"Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)","norm_bases":["Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na zwarcie zewnętrzne Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5) Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na zwarcie zewnetrzne Ζ Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)","categories":["electronics"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Resistance to external short circuit Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)","search_zh":"电气、电信与电子产品及设备 耐外部短路性 Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8 sekcja 38.3, punkt: 38.3.4.5 (Test T.5)","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"耐外部短路性"},{"_id":"6a5dc9acf1c10c8ce825a758","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na przeładowania","methodology_en":"Resistance to overcharging","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na przeładowania","reference":"Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)","norm_bases":["Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na przeładowania Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7) Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na przeladowania Ζ Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)","categories":["electronics"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Resistance to overcharging Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)","search_zh":"电气、电信与电子产品及设备 Ζ Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.7 sekcja 38.3, punkt: 38.3.4.1 (Test T.7)","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a759","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Sprawdzenie odporności na spadki wielokrotne. Próba Ec. Procedura 2.","methodology_en":"Verification of resistance to repeated free fall. Test Ec. Procedure 2.","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie odporności na spadki wielokrotne. Próba Ec. Procedura 2.","reference":"Ζ | PN-EN 60068-2-31 p. 5.3 | PN-EN IEC 60598-1:2025-04 p. 7.13.4 | PN-EN IEC 60598-1:2025-04 /A11:2025-08 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60335-1:2024-04 /A11:2024-10","norm_bases":["Ζ","PN-EN 60068-2-31 p. 5.3","PN-EN IEC 60598-1:2025-04 p. 7.13.4","PN-EN IEC 60598-1:2025-04 /A11:2025-08","PN-EN IEC 60335-1:2024-04 p. 21.1","PN-EN IEC 60335-1:2024-04 /A11:2024-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Sprawdzenie odporności na spadki wielokrotne. Próba Ec. Procedura 2. Ζ | PN-EN 60068-2-31 p. 5.3 | PN-EN IEC 60598-1:2025-04 p. 7.13.4 | PN-EN IEC 60598-1:2025-04 /A11:2025-08 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60335-1:2024-04 /A11:2024-10 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Sprawdzenie odpornosci na spadki wielokrotne. Proba Ec. Procedura 2. Ζ | PN-EN 60068-2-31 p. 5.3 | PN-EN IEC 60598-1:2025-04 p. 7.13.4 | PN-EN IEC 60598-1:2025-04 /A11:2025-08 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60335-1:2024-04 /A11:2024-10","categories":["electronics"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical, telecommunications and electronic products and equipment Verification of resistance to repeated free fall. Test Ec. Procedure 2. Ζ | PN-EN 60068-2-31 p. 5.3 | PN-EN IEC 60598-1:2025-04 p. 7.13.4 | PN-EN IEC 60598-1:2025-04 /A11:2025-08 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60335-1:2024-04 /A11:2024-10","search_zh":"电气、电信与电子产品及设备 Ζ | PN-EN 60068-2-31 p. 5.3 | PN-EN IEC 60598-1:2025-04 p. 7.13.4 | PN-EN IEC 60598-1:2025-04 /A11:2025-08 | PN-EN IEC 60335-1:2024-04 p. 21.1 | PN-EN IEC 60335-1:2024-04 /A11:2024-10","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5dc9acf1c10c8ce825a75a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne górnicze","test_object_en":"Mining electrical equipment","methodology":"Odstępy izolacyjne, Ochrona przed dotykiem bezpośrednim, Działanie, Poprawność działania styków dla złącz i sprzęgników, Nagrzewanie urządzeń (przyrosty temperatury) prądem do 10 kA i temp. do 200 °C","methodology_en":"Clearances, Protection against direct contact, Operation, Correct operation of contacts for connectors and couplers, Heating of equipment (temperature rise) with current up to 10 kA and temperature up to 200 °C","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odstępy izolacyjne, Ochrona przed dotykiem bezpośrednim, Działanie, Poprawność działania styków dla złącz i sprzęgników, Nagrzewanie urządzeń (przyrosty temperatury) prądem do 10 kA i temp. do 200 °C","reference":"Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003","norm_bases":["Ζ","PN-G-50003:2003","PN-G-50003:2003","PN-G-50003:2003","PN-G-50003:2003","PN-G-50003:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne górnicze Odstępy izolacyjne, Ochrona przed dotykiem bezpośrednim, Działanie, Poprawność działania styków dla złącz i sprzęgników, Nagrzewanie urządzeń (przyrosty temperatury) prądem do 10 kA i temp. do 200 °C Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 Urzadzenia elektryczne gornicze Odstepy izolacyjne, Ochrona przed dotykiem bezposrednim, Dzialanie, Poprawnosc dzialania stykow dla zlacz i sprzegnikow, Nagrzewanie urzadzen (przyrosty temperatury) pradem do 10 kA i temp. do 200 °C Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003","categories":["construction"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mining electrical equipment Clearances, Protection against direct contact, Operation, Correct operation of contacts for connectors and couplers, Heating of equipment (temperature rise) with current up to 10 kA and temperature up to 200 °C Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003"},{"_id":"6a5dc9acf1c10c8ce825a75b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne górnicze, Urządzenia automatyki i telekomunikacji górniczej.","test_object_en":"Mining electrical equipment, Mining automation and telecommunication equipment.","methodology":"Rezystancja izolacji zakres do 2,99 TΩ, napięcie pomiarowe (50 - 2500) V, Wytrzymałość elektryczna izolacji, napięcie probiercze do 50 kV AC i DC, moc transformatora probierczego do 5 kVA","methodology_en":"Insulation resistance range up to 2,99 TΩ, measuring voltage (50 - 2500) V, Dielectric strength of insulation, test voltage up to 50 kV AC and DC, test transformer power up to 5 kVA","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji zakres do 2,99 TΩ, napięcie pomiarowe (50 - 2500) V, Wytrzymałość elektryczna izolacji, napięcie probiercze do 50 kV AC i DC, moc transformatora probierczego do 5 kVA","reference":"Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997","norm_bases":["Ζ","PN-G-50003:2003","PN-G-50006:1997","PN-G-50003:2003","PN-G-50006:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne górnicze, Urządzenia automatyki i telekomunikacji górniczej. Rezystancja izolacji zakres do 2,99 TΩ, napięcie pomiarowe (50 - 2500) V, Wytrzymałość elektryczna izolacji, napięcie probiercze do 50 kV AC i DC, moc transformatora probierczego do 5 kVA Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997 Urzadzenia elektryczne gornicze, Urzadzenia automatyki i telekomunikacji gorniczej. Rezystancja izolacji zakres do 2,99 TΩ, napiecie pomiarowe (50 - 2500) V, Wytrzymalosc elektryczna izolacji, napiecie probiercze do 50 kV AC i DC, moc transformatora probierczego do 5 kVA Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997","categories":["construction"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mining electrical equipment, Mining automation and telecommunication equipment. Insulation resistance range up to 2,99 TΩ, measuring voltage (50 - 2500) V, Dielectric strength of insulation, test voltage up to 50 kV AC and DC, test transformer power up to 5 kVA Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997"},{"_id":"6a5dc9acf1c10c8ce825a75c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne górnicze do 6kV","test_object_en":"Mining electrical equipment up to 6kV","methodology":"Odstępy izolacyjne, Ochrona przed dotykiem bezpośrednim, Poprawność działania styków dla złącz i sprzęgników, Temperatura (przyrost temperatury)","methodology_en":"Clearances, Protection against direct contact, Correct operation of contacts for connectors and couplers, Temperature (temperature rise)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odstępy izolacyjne, Ochrona przed dotykiem bezpośrednim, Poprawność działania styków dla złącz i sprzęgników, Temperatura (przyrost temperatury)","reference":"Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003","norm_bases":["Ζ","PN-G-50003:2003","PN-G-50003:2003","PN-G-50003:2003","PN-G-50003:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne górnicze do 6kV Odstępy izolacyjne, Ochrona przed dotykiem bezpośrednim, Poprawność działania styków dla złącz i sprzęgników, Temperatura (przyrost temperatury) Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 Urzadzenia elektryczne gornicze do 6kV Odstepy izolacyjne, Ochrona przed dotykiem bezposrednim, Poprawnosc dzialania stykow dla zlacz i sprzegnikow, Temperatura (przyrost temperatury) Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003","categories":["construction"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mining electrical equipment up to 6kV Clearances, Protection against direct contact, Correct operation of contacts for connectors and couplers, Temperature (temperature rise) Ζ | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003 | PN-G-50003:2003"},{"_id":"6a5dc9acf1c10c8ce825a75d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia elektryczne górnicze, Urządzenia automatyki i telekomunikacji górniczej","test_object_en":"Mining electrical equipment, Mining automation and telecommunication equipment","methodology":"Rezystancja izolacji zakres do 2,99 TΩ, napięcie pomiarowe (50 - 2500) V","methodology_en":"Insulation resistance range up to 2,99 TΩ, measuring voltage (50 - 2500) V","parameters":[{"name":"Pomiar bezpośredni"},{"name":"Wytrzymałość elektryczna izolacji"},{"name":"napięcie probiercze","range":"do 50 kV"},{"name":"AC, moc transformatora probierczego","range":"do 5 kVA"},{"name":"Pomiar napięciem przemiennym sinusoidalnym"}],"parameters_en":[{"name":"Direct measurement"},{"name":"Dielectric strength of the insulation"},{"name":"test voltage","range":"do 50 kV"},{"name":"AC, power of the test transformer","range":"do 5 kVA"},{"name":"Measurement with sinusoidal alternating voltage"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji zakres do 2,99 TΩ, napięcie pomiarowe (50 - 2500) V\nZakres:\nPomiar bezpośredni\nWytrzymałość elektryczna izolacji\nnapięcie probiercze do 50 kV\nAC, moc transformatora probierczego do 5 kVA\nPomiar napięciem przemiennym sinusoidalnym","reference":"Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997","norm_bases":["Ζ","PN-G-50003:2003","PN-G-50006:1997","PN-G-50003:2003","PN-G-50006:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne górnicze, Urządzenia automatyki i telekomunikacji górniczej Rezystancja izolacji zakres do 2,99 TΩ, napięcie pomiarowe (50 - 2500) V\nZakres:\nPomiar bezpośredni\nWytrzymałość elektryczna izolacji\nnapięcie probiercze do 50 kV\nAC, moc transformatora probierczego do 5 kVA\nPomiar napięciem przemiennym sinusoidalnym Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997 Urzadzenia elektryczne gornicze, Urzadzenia automatyki i telekomunikacji gorniczej Rezystancja izolacji zakres do 2,99 TΩ, napiecie pomiarowe (50 - 2500) V\nZakres:\nPomiar bezposredni\nWytrzymalosc elektryczna izolacji\nnapiecie probiercze do 50 kV\nAC, moc transformatora probierczego do 5 kVA\nPomiar napieciem przemiennym sinusoidalnym Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997","categories":["construction"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mining electrical equipment, Mining automation and telecommunication equipment Insulation resistance range up to 2,99 TΩ, measuring voltage (50 - 2500) V Direct measurement Dielectric strength of the insulation test voltage AC, power of the test transformer Measurement with sinusoidal alternating voltage Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997","parameters_zh":[{"name":"直接测量"},{"name":"绝缘介电强度"},{"name":"napięcie probiercze","range":"do 50 kV"},{"name":"AC, moc transformatora probierczego","range":"do 5 kVA"},{"name":"Pomiar napięciem przemiennym sinusoidalnym"}],"search_zh":"直接测量 绝缘介电强度 Ζ | PN-G-50003:2003 | PN-G-50006:1997 | PN-G-50003:2003 | PN-G-50006:1997"},{"_id":"6a5dc9acf1c10c8ce825a75e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","test_object_en":"Audio/video, information technology and telecommunications equipment","methodology":"Określenie dostępnych części przewodzących","methodology_en":"Determination of accessible conductive parts","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Określenie dostępnych części przewodzących","reference":"Ζ | PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3 | PN-EN IEC 62368-1:2024-06/A11:2025-01","norm_bases":["Ζ","PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3","PN-EN IEC 62368-1:2024-06/A11:2025-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Określenie dostępnych części przewodzących Ζ | PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3 | PN-EN IEC 62368-1:2024-06/A11:2025-01 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Okreslenie dostepnych czesci przewodzacych Ζ | PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3 | PN-EN IEC 62368-1:2024-06/A11:2025-01","categories":["other"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Audio/video, information technology and telecommunications equipment Determination of accessible conductive parts Ζ | PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3 | PN-EN IEC 62368-1:2024-06/A11:2025-01","search_zh":"音频/视频、信息技术与电信设备 Ζ | PN-EN IEC 62368-1:2024-06 p. V.1.2 - V.1.6 T.3 | PN-EN IEC 62368-1:2024-06/A11:2025-01","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a5dc9acf1c10c8ce825a75f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","test_object_en":"Audio/video, information technology and telecommunications equipment","methodology":"Kondycjonowanie w wilgotności","methodology_en":"Humidity conditioning","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kondycjonowanie w wilgotności","reference":"Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.8 | PN-EN IEC 62368-1:2024-06/A11:2025-01","norm_bases":["Ζ","PN-EN IEC 62368-1:2024-06 p. 5.4.8","PN-EN IEC 62368-1:2024-06/A11:2025-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Kondycjonowanie w wilgotności Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.8 | PN-EN IEC 62368-1:2024-06/A11:2025-01 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Kondycjonowanie w wilgotnosci Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.8 | PN-EN IEC 62368-1:2024-06/A11:2025-01","categories":["other"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Audio/video, information technology and telecommunications equipment Humidity conditioning Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.8 | PN-EN IEC 62368-1:2024-06/A11:2025-01","search_zh":"音频/视频、信息技术与电信设备 Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.8 | PN-EN IEC 62368-1:2024-06/A11:2025-01","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a5dc9acf1c10c8ce825a760","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","test_object_en":"Audio/video, information technology and telecommunications equipment","methodology":"Wytrzymałość elektryczna","methodology_en":"Electric strength","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna","reference":"Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.9.1 | PN-EN IEC 62368-1:2024-06/A11:2025-01","norm_bases":["Ζ","PN-EN IEC 62368-1:2024-06 p. 5.4.9.1","PN-EN IEC 62368-1:2024-06/A11:2025-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Wytrzymałość elektryczna Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.9.1 | PN-EN IEC 62368-1:2024-06/A11:2025-01 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Wytrzymalosc elektryczna Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.9.1 | PN-EN IEC 62368-1:2024-06/A11:2025-01","categories":["other"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Audio/video, information technology and telecommunications equipment Electric strength Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.9.1 | PN-EN IEC 62368-1:2024-06/A11:2025-01","search_zh":"音频/视频、信息技术与电信设备 介电强度 Ζ | PN-EN IEC 62368-1:2024-06 p. 5.4.9.1 | PN-EN IEC 62368-1:2024-06/A11:2025-01","test_object_zh":"音频/视频、信息技术与电信设备","methodology_zh":"介电强度"},{"_id":"6a5dc9acf1c10c8ce825a761","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej","test_object_en":"Audio/video, information technology and telecommunications equipment","methodology":"Sprawdzenie maksymalnych temperatur pracy dla materiałów, komponentów i systemów oraz miejsc dotykowych","methodology_en":"Verification of maximum operating temperatures for materials, components and systems and for touchable parts","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie maksymalnych temperatur pracy dla materiałów, komponentów i systemów oraz miejsc dotykowych","reference":"Ζ | PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2 | PN-EN IEC 62368-1:2024-06/A11:2025-01","norm_bases":["Ζ","PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2","PN-EN IEC 62368-1:2024-06/A11:2025-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Sprawdzenie maksymalnych temperatur pracy dla materiałów, komponentów i systemów oraz miejsc dotykowych Ζ | PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2 | PN-EN IEC 62368-1:2024-06/A11:2025-01 Urzadzenia techniki fonicznej/wizyjnej, informatycznej i telekomunikacyjnej Sprawdzenie maksymalnych temperatur pracy dla materialow, komponentow i systemow oraz miejsc dotykowych Ζ | PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2 | PN-EN IEC 62368-1:2024-06/A11:2025-01","categories":["materials"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Audio/video, information technology and telecommunications equipment Verification of maximum operating temperatures for materials, components and systems and for touchable parts Ζ | PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2 | PN-EN IEC 62368-1:2024-06/A11:2025-01","search_zh":"音频/视频、信息技术与电信设备 Ζ | PN-EN IEC 62368-1:2024-06 p.5.4.1.4, p.9.3.2 | PN-EN IEC 62368-1:2024-06/A11:2025-01","test_object_zh":"音频/视频、信息技术与电信设备"},{"_id":"6a5dc9acf1c10c8ce825a762","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczny sprzęt do użytku domowego i podobnego","test_object_en":"Electrical appliances for household and similar use","methodology":"Sprawdzenie ochrony przed dostępem do części czynnych","methodology_en":"Verification of protection against access to live parts","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie ochrony przed dostępem do części czynnych","reference":"Ζ | PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3 | PN-EN IEC 60335-1:2024-04/A11:2024-10","norm_bases":["Ζ","PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3","PN-EN IEC 60335-1:2024-04/A11:2024-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczny sprzęt do użytku domowego i podobnego Sprawdzenie ochrony przed dostępem do części czynnych Ζ | PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3 | PN-EN IEC 60335-1:2024-04/A11:2024-10 Elektryczny sprzet do uzytku domowego i podobnego Sprawdzenie ochrony przed dostepem do czesci czynnych Ζ | PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3 | PN-EN IEC 60335-1:2024-04/A11:2024-10","categories":["other"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical appliances for household and similar use Verification of protection against access to live parts Ζ | PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3 | PN-EN IEC 60335-1:2024-04/A11:2024-10","search_zh":"家用及类似用途电器 Ζ | PN-EN IEC 60335-1:2024-04 p. 8.1.1, 8.1.2, 8.1.3 | PN-EN IEC 60335-1:2024-04/A11:2024-10","test_object_zh":"家用及类似用途电器"},{"_id":"6a5dc9acf1c10c8ce825a763","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne","test_object_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable","methodology":"Odchylenia","methodology_en":"Deviations","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchylenia","reference":"Ζ | PN-EN 45544-1:2015-08 p. 5.4.3","norm_bases":["Ζ","PN-EN 45544-1:2015-08 p. 5.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne Odchylenia Ζ | PN-EN 45544-1:2015-08 p. 5.4.3 Elektryczne przyrzady stosowane do bezposredniego wykrywania i bezposredniego pomiaru stezenia toksycznych gazow: - Przyrzady do pomiarow stezen w zakresie wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie do 500 ppm CO: - Przyrzady do pomiarow stezen znacznie powyzej wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie powyzej 500 ppm CO: Przyrzady do pomiaru gazow toksycznych: - stacjonarne - przenosne - przewozne Odchylenia Ζ | PN-EN 45544-1:2015-08 p. 5.4.3","categories":["other"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Deviations Ζ | PN-EN 45544-1:2015-08 p. 5.4.3","search_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器 Ζ | PN-EN 45544-1:2015-08 p. 5.4.3","test_object_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器"},{"_id":"6a5dc9acf1c10c8ce825a764","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne","test_object_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable","methodology":"Progi alarmowe","methodology_en":"Alarm thresholds","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Progi alarmowe","reference":"Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.1","norm_bases":["Ζ","PN-EN 45544-1:2015-08 p. 5.4.6.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne Progi alarmowe Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.1 Elektryczne przyrzady stosowane do bezposredniego wykrywania i bezposredniego pomiaru stezenia toksycznych gazow: - Przyrzady do pomiarow stezen w zakresie wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie do 500 ppm CO: - Przyrzady do pomiarow stezen znacznie powyzej wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie powyzej 500 ppm CO: Przyrzady do pomiaru gazow toksycznych: - stacjonarne - przenosne - przewozne Progi alarmowe Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.1","categories":["other"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Alarm thresholds Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.1","search_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器 Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.1","test_object_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器"},{"_id":"6a5dc9acf1c10c8ce825a765","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne","test_object_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable","methodology":"Czas nagrzewania","methodology_en":"Heating time","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas nagrzewania","reference":"Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.4","norm_bases":["Ζ","PN-EN 45544-1:2015-08 p. 5.4.6.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne Czas nagrzewania Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.4 Elektryczne przyrzady stosowane do bezposredniego wykrywania i bezposredniego pomiaru stezenia toksycznych gazow: - Przyrzady do pomiarow stezen w zakresie wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie do 500 ppm CO: - Przyrzady do pomiarow stezen znacznie powyzej wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie powyzej 500 ppm CO: Przyrzady do pomiaru gazow toksycznych: - stacjonarne - przenosne - przewozne Czas nagrzewania Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.4","categories":["other"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Heating time Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.4","search_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器 Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.4","test_object_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器"},{"_id":"6a5dc9acf1c10c8ce825a766","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne","test_object_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable","methodology":"Czas reakcji","methodology_en":"Response time","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas reakcji","reference":"Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.5","norm_bases":["Ζ","PN-EN 45544-1:2015-08 p. 5.4.6.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne Czas reakcji Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.5 Elektryczne przyrzady stosowane do bezposredniego wykrywania i bezposredniego pomiaru stezenia toksycznych gazow: - Przyrzady do pomiarow stezen w zakresie wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie do 500 ppm CO: - Przyrzady do pomiarow stezen znacznie powyzej wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie powyzej 500 ppm CO: Przyrzady do pomiaru gazow toksycznych: - stacjonarne - przenosne - przewozne Czas reakcji Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.5","categories":["other"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Response time Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.5","search_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器 Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.5","test_object_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器"},{"_id":"6a5dc9acf1c10c8ce825a767","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne","test_object_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable","methodology":"Czas relaksacji","methodology_en":"Relaxation time","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas relaksacji","reference":"Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.6.","norm_bases":["Ζ","PN-EN 45544-1:2015-08 p. 5.4.6.6."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne Czas relaksacji Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.6. Elektryczne przyrzady stosowane do bezposredniego wykrywania i bezposredniego pomiaru stezenia toksycznych gazow: - Przyrzady do pomiarow stezen w zakresie wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie do 500 ppm CO: - Przyrzady do pomiarow stezen znacznie powyzej wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie powyzej 500 ppm CO: Przyrzady do pomiaru gazow toksycznych: - stacjonarne - przenosne - przewozne Czas relaksacji Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.6.","categories":["other"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Relaxation time Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.6.","search_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器 Ζ | PN-EN 45544-1:2015-08 p. 5.4.6.6.","test_object_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器"},{"_id":"6a5dc9acf1c10c8ce825a768","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne","test_object_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable","methodology":"Dryft","methodology_en":"Drift","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Dryft","reference":"Ζ | PN-EN 45544-1:2015-08 p. 5.4.8","norm_bases":["Ζ","PN-EN 45544-1:2015-08 p. 5.4.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektryczne przyrządy stosowane do bezpośredniego wykrywania i bezpośredniego pomiaru stężenia toksycznych gazów: - Przyrządy do pomiarów stężeń w zakresie wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie do 500 ppm CO: - Przyrządy do pomiarów stężeń znacznie powyżej wartości dopuszczalnych. Przyrządy do pomiaru tlenku węgla w zakresie powyżej 500 ppm CO: Przyrządy do pomiaru gazów toksycznych: - stacjonarne - przenośne - przewoźne Dryft Ζ | PN-EN 45544-1:2015-08 p. 5.4.8 Elektryczne przyrzady stosowane do bezposredniego wykrywania i bezposredniego pomiaru stezenia toksycznych gazow: - Przyrzady do pomiarow stezen w zakresie wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie do 500 ppm CO: - Przyrzady do pomiarow stezen znacznie powyzej wartosci dopuszczalnych. Przyrzady do pomiaru tlenku wegla w zakresie powyzej 500 ppm CO: Przyrzady do pomiaru gazow toksycznych: - stacjonarne - przenosne - przewozne Dryft Ζ | PN-EN 45544-1:2015-08 p. 5.4.8","categories":["other"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical instruments used for the direct detection and direct concentration measurement of toxic gases: - Instruments for measuring concentrations in the range of limit values. Instruments for measuring carbon monoxide in the range up to 500 ppm CO: - Instruments for measuring concentrations well above limit values. Instruments for measuring carbon monoxide in the range above 500 ppm CO: Instruments for measuring toxic gases: - stationary - portable - transportable Drift Ζ | PN-EN 45544-1:2015-08 p. 5.4.8","search_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器 Ζ | PN-EN 45544-1:2015-08 p. 5.4.8","test_object_zh":"用于直接检测与直接测量有毒气体浓度的电气仪器：－ 在容许值范围内测量浓度的仪器。测量一氧化碳、量程至 500 ppm CO 的仪器：－ 测量远高于容许值浓度的仪器。测量一氧化碳、量程高于 500 ppm CO 的仪器：测量仪器"},{"_id":"6a5dc9acf1c10c8ce825a769","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Progi alarmowe","methodology_en":"Feature: Alarm thresholds","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Progi alarmowe\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.2 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.2","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Progi alarmowe\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.2 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Progi alarmowe\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.2 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm thresholds Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.2 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.2 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a76a","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Kondycjonowanie bez zasilania","methodology_en":"Feature: Conditioning without power supply","parameters":[{"name":"Zakres","range":"(od -20 do +60) °C"}],"parameters_en":[{"name":"Range","range":"(od -20 do +60) °C"}],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Kondycjonowanie bez zasilania\nZakres (od -20 do +60) °C\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.1.5 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.1.5","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Kondycjonowanie bez zasilania\nZakres (od -20 do +60) °C\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.1.5 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Kondycjonowanie bez zasilania\nZakres (od -20 do +60) °C\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.1.5 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Conditioning without power supply Method: direct method Range Ζ | PN-EN 50291-1:2018-06 p.6.1.5 | PN-EN 50291-1:2018-06/AC:2021-03","parameters_zh":[{"name":"范围","range":"(od -20 do +60) °C"}],"search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 范围 Ζ | PN-EN 50291-1:2018-06 p.6.1.5 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a76b","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Wyjścia sygnałowe","methodology_en":"Feature: Signal outputs","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Wyjścia sygnałowe\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.3 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.3","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Wyjścia sygnałowe\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.3 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Wyjscia sygnalowe\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.3 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Signal outputs Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.3 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.3 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a76c","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Czas działania alarmu","methodology_en":"Feature: Alarm operating time","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Czas działania alarmu\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.4 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.4","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Czas działania alarmu\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.4 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Czas dzialania alarmu\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.4 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm operating time Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.4 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.4 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a76d","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Czas reakcji alarmu podczas nagrzewania","methodology_en":"Feature: Alarm response time during heating","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Czas reakcji alarmu podczas nagrzewania\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.5 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.5","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Czas reakcji alarmu podczas nagrzewania\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.5 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Czas reakcji alarmu podczas nagrzewania\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.5 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":157,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm response time during heating Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.5 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.5 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a76e","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Wpływ temperatury gazu na urządzenie","methodology_en":"Feature: Influence of gas temperature on the device","parameters":[{"name":"Zakres","range":"(od -20 do +60) °C"}],"parameters_en":[{"name":"Range","range":"(od -20 do +60) °C"}],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Wpływ temperatury gazu na urządzenie\nZakres (od -20 do +60) °C\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.7 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.7","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Wpływ temperatury gazu na urządzenie\nZakres (od -20 do +60) °C\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.7 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Wplyw temperatury gazu na urzadzenie\nZakres (od -20 do +60) °C\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.7 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":158,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of gas temperature on the device Method: direct method Range Ζ | PN-EN 50291-1:2018-06 p.6.3.7 | PN-EN 50291-1:2018-06/AC:2021-03","parameters_zh":[{"name":"范围","range":"(od -20 do +60) °C"}],"search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 范围 Ζ | PN-EN 50291-1:2018-06 p.6.3.7 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a76f","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Wpływ wilgotności gazu na urządzenie","methodology_en":"Feature: Influence of gas humidity on the device","parameters":[{"name":"Zakres","range":"(20 - 95)% rh"}],"parameters_en":[{"name":"Range","range":"(20 - 95)% rh"}],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Wpływ wilgotności gazu na urządzenie\nZakres (20 - 95)% rh\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.8 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.8","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Wpływ wilgotności gazu na urządzenie\nZakres (20 - 95)% rh\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.8 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Wplyw wilgotnosci gazu na urzadzenie\nZakres (20 - 95)% rh\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.8 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":159,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of gas humidity on the device Method: direct method Range Ζ | PN-EN 50291-1:2018-06 p.6.3.8 | PN-EN 50291-1:2018-06/AC:2021-03","parameters_zh":[{"name":"范围","range":"(20 - 95)% rh"}],"search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 范围 Ζ | PN-EN 50291-1:2018-06 p.6.3.8 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a770","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Wpływ prędkości przepływu gazu na urządzenie","methodology_en":"Feature: Influence of gas flow rate on the device","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Wpływ prędkości przepływu gazu na urządzenie\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.9 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.9","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Wpływ prędkości przepływu gazu na urządzenie\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.9 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Wplyw predkosci przeplywu gazu na urzadzenie\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.9 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":160,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of gas flow rate on the device Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.9 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.9 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a771","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Wpływ zmian zasilania na urządzenie","methodology_en":"Feature: Influence of power supply variations on the device","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Wpływ zmian zasilania na urządzenie\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.10 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.10","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Wpływ zmian zasilania na urządzenie\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.10 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Wplyw zmian zasilania na urzadzenie\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.10 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":161,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Influence of power supply variations on the device Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.10 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.10 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a772","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Stabilność długookresowa","methodology_en":"Feature: Long-term stability","parameters":[],"parameters_en":[],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Stabilność długookresowa\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.14 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.14","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Stabilność długookresowa\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.14 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Stabilnosc dlugookresowa\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.14 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":162,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Long-term stability Method: direct method Ζ | PN-EN 50291-1:2018-06 p.6.3.14 | PN-EN 50291-1:2018-06/AC:2021-03","search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 Ζ | PN-EN 50291-1:2018-06 p.6.3.14 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a773","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych","test_object_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises","methodology":"Cecha: Poziom dźwięku alarmu","methodology_en":"Feature: Alarm sound level","parameters":[{"name":"Zakres","range":"(80 - 110) dB (A)"}],"parameters_en":[{"name":"Range","range":"(80 - 110) dB (A)"}],"technique":"Metoda: metoda bezpośrednia","techniques":["Metoda: metoda bezpośrednia"],"technique_en":"Method: direct method","computed":[],"computed_en":[],"activity":"Cecha: Poziom dźwięku alarmu\nZakres (80 - 110) dB (A)\nMetoda: metoda bezpośrednia","reference":"Ζ | PN-EN 50291-1:2018-06 p.6.3.16 | PN-EN 50291-1:2018-06/AC:2021-03","norm_bases":["Ζ","PN-EN 50291-1:2018-06 p.6.3.16","PN-EN 50291-1:2018-06/AC:2021-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykrywacze gazu, Urządzenia elektryczne do wykrywania tlenku węgla w pomieszczeniach domowych Cecha: Poziom dźwięku alarmu\nZakres (80 - 110) dB (A)\nMetoda: metoda bezpośrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.16 | PN-EN 50291-1:2018-06/AC:2021-03 Wykrywacze gazu, Urzadzenia elektryczne do wykrywania tlenku wegla w pomieszczeniach domowych Cecha: Poziom dzwieku alarmu\nZakres (80 - 110) dB (A)\nMetoda: metoda bezposrednia Ζ | PN-EN 50291-1:2018-06 p.6.3.16 | PN-EN 50291-1:2018-06/AC:2021-03","categories":["other"],"row_index":163,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas detectors, Electrical apparatus for the detection of carbon monoxide in domestic premises Feature: Alarm sound level Method: direct method Range Ζ | PN-EN 50291-1:2018-06 p.6.3.16 | PN-EN 50291-1:2018-06/AC:2021-03","parameters_zh":[{"name":"范围","range":"(80 - 110) dB (A)"}],"search_zh":"气体探测器、家用场所一氧化碳探测用电气设备 方法：直接法 范围 Ζ | PN-EN 50291-1:2018-06 p.6.3.16 | PN-EN 50291-1:2018-06/AC:2021-03","technique_zh":"方法：直接法","test_object_zh":"气体探测器、家用场所一氧化碳探测用电气设备"},{"_id":"6a5dc9acf1c10c8ce825a774","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Badanie iskrobezpieczeństwa za pomocą iskiernika","methodology_en":"Intrinsic safety testing using a spark test apparatus","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie iskrobezpieczeństwa za pomocą iskiernika","reference":"Ζ | PN-EN 60079-11:2012 p. 10.1","norm_bases":["Ζ","PN-EN 60079-11:2012 p. 10.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Badanie iskrobezpieczeństwa za pomocą iskiernika Ζ | PN-EN 60079-11:2012 p. 10.1 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Badanie iskrobezpieczenstwa za pomoca iskiernika Ζ | PN-EN 60079-11:2012 p. 10.1","categories":["other"],"row_index":164,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Intrinsic safety testing using a spark test apparatus Ζ | PN-EN 60079-11:2012 p. 10.1","search_zh":"本质安全型「i」防爆设备 Ζ | PN-EN 60079-11:2012 p. 10.1","test_object_zh":"本质安全型「i」防爆设备"},{"_id":"6a5dc9acf1c10c8ce825a775","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Badanie ogniw i baterii","methodology_en":"Testing of cells and batteries","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie ogniw i baterii","reference":"Ζ | PN-EN 60079-11:2012 p. 10.5","norm_bases":["Ζ","PN-EN 60079-11:2012 p. 10.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Badanie ogniw i baterii Ζ | PN-EN 60079-11:2012 p. 10.5 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Badanie ogniw i baterii Ζ | PN-EN 60079-11:2012 p. 10.5","categories":["other"],"row_index":165,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Testing of cells and batteries Ζ | PN-EN 60079-11:2012 p. 10.5","search_zh":"本质安全型「i」防爆设备 Ζ | PN-EN 60079-11:2012 p. 10.5","test_object_zh":"本质安全型「i」防爆设备"},{"_id":"6a5dc9acf1c10c8ce825a776","lab_id":"69ad52a3de79e566650fb189","country":"PL","accr_number":"AB 261","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Pomiary wielkości geometrycznych (odstępów izolacyjnych)","methodology_en":"Measurements of geometric quantities (insulation clearances)","parameters":[],"parameters_en":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Pomiary wielkości geometrycznych (odstępów izolacyjnych)\nMetoda bezpośrednia","reference":"Ζ | PN-EN 60079-11:2012 p. 6.3","norm_bases":["Ζ","PN-EN 60079-11:2012 p. 6.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Pomiary wielkości geometrycznych (odstępów izolacyjnych)\nMetoda bezpośrednia Ζ | PN-EN 60079-11:2012 p. 6.3 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Pomiary wielkosci geometrycznych (odstepow izolacyjnych)\nMetoda bezposrednia Ζ | PN-EN 60079-11:2012 p. 6.3","categories":["construction"],"row_index":166,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Measurements of geometric quantities (insulation clearances) Direct method Ζ | PN-EN 60079-11:2012 p. 6.3","search_zh":"本质安全型「i」防爆设备 直接法 Ζ | PN-EN 60079-11:2012 p. 6.3","technique_zh":"直接法","test_object_zh":"本质安全型「i」防爆设备"}],"has_pdf":true}