🇵🇱 STRABAG PFS Sp. z o.o. PL
EnvironmentMaterials & polymers
STRABAG PFS Sp. z o.o. is a laboratory accredited by PCA under number AB 243 (Kraków, Poland). Its accreditation scope covers 9 test methods in the following areas: Environment, Materials & polymers. Test objects include: Workplace environment – air, Air filter, Cleanrooms and laminar flow cabinets, Compressed air and industrial gases (nitrogen and oxygen). Most frequently used techniques: Measurement method using a particle counter, Measurement method using a linear photometer, Indirect measurement method; Direct measurement method.
At a glance
- Accreditation number: PCA AB 243
- Methods in scope: 9
- Types of test objects: 5
- Techniques used: 3
- City: Kraków, Poland
- Accreditation number
- AB 243
- Accreditation body
- PCA
- Address
- ul. Parzniewska 10, 05-800 Pruszków, SEKCJA POMIARÓW I WALIDACJI STRABAG PFS Sp. z o.o., ul. Wielicka 181a/21, 30-663 Kraków
- City
- Kraków, Poland
What this laboratory tests (5)
- Workplace environment – air — 5 methods
- Air filter — 1 method
- Cleanrooms and laminar flow cabinets — 1 method
- Compressed air and industrial gases (nitrogen and oxygen) — 1 method
- Ventilation — 1 method
Analytical techniques used (3)
- Measurement method using a particle counter — 3 methods
- Measurement method using a linear photometer — 2 methods
- Indirect measurement method; Direct measurement method — 1 method
Accreditation scope — test methods (9)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment – air | Cleanliness: number content of particles with diameters: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm (from 1 to 349.999.965) particles/m3 |
Measurement method using a particle counter | PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10 | PN-EN ISO 14644-1:2016-03 | |
| 2 | Workplace environment – air | Recovery time to the initial air cleanliness: number content of particles with diameters: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm (from 1 to 349.999.965) particles/m3 |
Measurement method using a particle counter | PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4 | PN-EN ISO 14644-1:2016-03 | |
| 3 | Workplace environment – air | Temperature range (od +5 do +42) °C |
PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5 | ||
| 4 | Workplace environment – air | Relative humidity range (10 - 85) % RH |
PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6 | ||
| 5 | Workplace environment – air | Pressure difference: range (-2500 - +2500) Pa |
PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1 | ||
| 6 | Air filter | Homogeneity of the filter medium (leak test) and tightness of the filter mounting particle mass concentration Range (0,0003 - 100) μg/l |
Measurement method using a linear photometer | PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6 | |
| 7 | Ventilation | Air velocity Range (0,2 - 40) m/s Air volume flow rate for determining the number of air changes Range (50 - 2000) m3/godz. |
Indirect measurement method; Direct measurement method | PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2 | |
| 8 | Cleanrooms and laminar flow cabinets | Penetration - mass concentration of particles Range (0,0003 - 100) μg/l |
Measurement method using a linear photometer | PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8 | |
| 9 | Compressed air and industrial gases (nitrogen and oxygen) | Cleanliness - particle number concentration for diameters: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm (from 1 to 349.999.965) particles/m3 |
Measurement method using a particle counter | Procedura 0100 edycja 13 z dnia 20.03.2020 r. | |
Reference standards (11)
PN-EN 1822-1:2019-05 pkt. 5 i 6
PN-EN ISO 14644-1:2016-03
PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1
PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10
PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2
PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4
PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5
PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6
PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7
PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8
Procedura 0100 edycja 13 z dnia 20.03.2020 r.