{"lab":{"_id":"69ad52a3de79e566650fb17d","accr_number":"AB 243","country":"PL","accr_body":"PCA","address":"ul. Parzniewska 10, 05-800 Pruszków, SEKCJA POMIARÓW I WALIDACJI STRABAG PFS Sp. z o.o., ul. Wielicka 181a/21, 30-663 Kraków","categories":["environment","materials"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"STRABAG PFS Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_243.pdf"],"scope_summary":"","search_text":"strabag pfs sp. z o.o. ul. parzniewska 10, 05-800 pruszków, sekcja pomiarów i walidacji strabag pfs sp. z o.o., ul. wielicka 181a/21, 30-663 kraków environment other materials automotive food metrology","status":"active","updated_at":"2026-03-08T14:51:06.445Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:06.445Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20243,podmiot.html","fields_of_testing":[{"codes":"N/33, N/35, N/40, N/36, N/41","pl":"Badania właściwości fizycznych – powietrze, gazy techniczne, pomieszczenia czyste i komory laminarne, filtr powietrza","en":"Tests of physical properties - air, technical gases, clean facilities, laminar chambers, air filter"},{"codes":"G/35","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – pomieszczenia (warunki środowiskowe – wentylacja)","en":"Tests concerning environmental engineering (environmental and climatic) – facilities (environmental conditions - ventilation)"}],"issue":{"no":"27","date":"09.12.2025"},"parse_date":"2026-07-20T07:09:58.006Z","parse_source":"script-pdfplumber","map_coord":[50.061947,19.936856],"map_geo":"nominatim-city","has_en":true,"category_counts":{"environment":6,"other":2,"materials":1},"category_scores":{"environment":4,"other":0.44,"materials":0.11},"has_zh":true},"methods":[{"_id":"6a5dc9c6f1c10c8ce826049e","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Czystość:","methodology_en":"Cleanliness:","parameters":[{"name":"zawartość liczbowa cząstek o średnicach:","range":"(0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm"},{"name":"(od 1 do 349.999.965) cząstek/m3"}],"parameters_en":[{"name":"number content of particles with diameters:","range":"(0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm"},{"name":"(from 1 to 349.999.965) particles/m3"}],"technique":"Metoda pomiaru licznikiem cząstek","techniques":["Metoda pomiaru licznikiem cząstek"],"technique_en":"Measurement method using a particle counter","computed":[],"computed_en":[],"activity":"Czystość:\nZakres:\nzawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) cząstek/m3\nMetoda pomiaru licznikiem cząstek","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10 | PN-EN ISO 14644-1:2016-03","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10","PN-EN ISO 14644-1:2016-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Czystość:\nZakres:\nzawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) cząstek/m3\nMetoda pomiaru licznikiem cząstek PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10 | PN-EN ISO 14644-1:2016-03 Srodowisko pracy – powietrze Czystosc:\nZakres:\nzawartosc liczbowa czastek o srednicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) czastek/m3\nMetoda pomiaru licznikiem czastek PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i zalacznik B.10 | PN-EN ISO 14644-1:2016-03","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Cleanliness: Measurement method using a particle counter number content of particles with diameters: (from 1 to 349.999.965) particles/m3 PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10 | PN-EN ISO 14644-1:2016-03","search_zh":"工作场所环境 — 空气 粒子计数器测量法 (1 至 349.999.965) 个粒子/m3 PN-EN ISO 14644-3:2020-03 pkt. 4.2.10 i załącznik B.10 | PN-EN ISO 14644-1:2016-03","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"zawartość liczbowa cząstek o średnicach:","range":"(0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm"},{"name":"(1 至 349.999.965) 个粒子/m3"}],"technique_zh":"粒子计数器测量法"},{"_id":"6a5dc9c6f1c10c8ce826049f","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Czas osiągnięcia czystości początkowej powietrza:","methodology_en":"Recovery time to the initial air cleanliness:","parameters":[{"name":"zawartość liczbowa cząstek o średnicach:","range":"(0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm"},{"name":"(od 1 do 349.999.965) cząstek/m3"}],"parameters_en":[{"name":"number content of particles with diameters:","range":"(0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm"},{"name":"(from 1 to 349.999.965) particles/m3"}],"technique":"Metoda pomiaru licznikiem cząstek","techniques":["Metoda pomiaru licznikiem cząstek"],"technique_en":"Measurement method using a particle counter","computed":[],"computed_en":[],"activity":"Czas osiągnięcia czystości początkowej powietrza:\nZakres:\nzawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) cząstek/m3\nMetoda pomiaru licznikiem cząstek","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4 | PN-EN ISO 14644-1:2016-03","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4","PN-EN ISO 14644-1:2016-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Czas osiągnięcia czystości początkowej powietrza:\nZakres:\nzawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) cząstek/m3\nMetoda pomiaru licznikiem cząstek PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4 | PN-EN ISO 14644-1:2016-03 Srodowisko pracy – powietrze Czas osiagniecia czystosci poczatkowej powietrza:\nZakres:\nzawartosc liczbowa czastek o srednicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) czastek/m3\nMetoda pomiaru licznikiem czastek PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i zalacznik B.4 | PN-EN ISO 14644-1:2016-03","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Recovery time to the initial air cleanliness: Measurement method using a particle counter number content of particles with diameters: (from 1 to 349.999.965) particles/m3 PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4 | PN-EN ISO 14644-1:2016-03","search_zh":"工作场所环境 — 空气 粒子计数器测量法 (1 至 349.999.965) 个粒子/m3 PN-EN ISO 14644-3:2020-03 pkt. 4.2.4 i załącznik B.4 | PN-EN ISO 14644-1:2016-03","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"zawartość liczbowa cząstek o średnicach:","range":"(0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm"},{"name":"(1 至 349.999.965) 个粒子/m3"}],"technique_zh":"粒子计数器测量法"},{"_id":"6a5dc9c6f1c10c8ce82604a0","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Temperatura","methodology_en":"Temperature","parameters":[{"name":"zakres","range":"(od +5 do +42) °C"}],"parameters_en":[{"name":"range","range":"(od +5 do +42) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura\nzakres (od +5 do +42) °C","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Temperatura\nzakres (od +5 do +42) °C PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5 Srodowisko pracy – powietrze Temperatura\nzakres (od +5 do +42) °C PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i zalacznik B.5","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Temperature range PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5","search_zh":"工作场所环境 — 空气 温度 范围 PN-EN ISO 14644-3:2020-03 pkt. 4.2.5 i załącznik B.5","test_object_zh":"工作场所环境 — 空气","methodology_zh":"温度","parameters_zh":[{"name":"范围","range":"(od +5 do +42) °C"}]},{"_id":"6a5dc9c6f1c10c8ce82604a1","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Wilgotność względna","methodology_en":"Relative humidity","parameters":[{"name":"zakres","range":"(10 - 85) % RH"}],"parameters_en":[{"name":"range","range":"(10 - 85) % RH"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wilgotność względna\nzakres (10 - 85) % RH","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Wilgotność względna\nzakres (10 - 85) % RH PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6 Srodowisko pracy – powietrze Wilgotnosc wzgledna\nzakres (10 - 85) % RH PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i zalacznik B.6","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Relative humidity range PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6","search_zh":"工作场所环境 — 空气 相对湿度 范围 PN-EN ISO 14644-3:2020-03 pkt. 4.2.6 i załącznik B.6","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"范围","range":"(10 - 85) % RH"}],"methodology_zh":"相对湿度"},{"_id":"6a5dc9c6f1c10c8ce82604a2","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Różnica ciśnień:","methodology_en":"Pressure difference:","parameters":[{"name":"zakres","range":"(-2500 - +2500) Pa"}],"parameters_en":[{"name":"range","range":"(-2500 - +2500) Pa"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Różnica ciśnień:\nzakres (-2500 - +2500) Pa","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Różnica ciśnień:\nzakres (-2500 - +2500) Pa PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1 Srodowisko pracy – powietrze Roznica cisnien:\nzakres (-2500 - +2500) Pa PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i zalacznik B.1","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Pressure difference: range PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1","search_zh":"工作场所环境 — 空气 范围 PN-EN ISO 14644-3:2020-03 pkt. 4.2.1 i załącznik B.1","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"范围","range":"(-2500 - +2500) Pa"}]},{"_id":"6a5dc9c6f1c10c8ce82604a3","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Filtr powietrza","test_object_en":"Air filter","methodology":"Jednorodność materiału filtrującego (badanie przecieków) oraz szczelność mocowania filtra","methodology_en":"Homogeneity of the filter medium (leak test) and tightness of the filter mounting","parameters":[{"name":"stężenie masowe cząstek"},{"name":"Zakres","range":"(0,0003 - 100) μg/l"}],"parameters_en":[{"name":"particle mass concentration"},{"name":"Range","range":"(0,0003 - 100) μg/l"}],"technique":"Metoda pomiaru fotometrem liniowym","techniques":["Metoda pomiaru fotometrem liniowym"],"technique_en":"Measurement method using a linear photometer","computed":[],"computed_en":[],"activity":"Jednorodność materiału filtrującego (badanie przecieków) oraz szczelność mocowania filtra\nZakres:\nstężenie masowe cząstek\nZakres (0,0003 - 100) μg/l\nMetoda pomiaru fotometrem liniowym","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7","PN-EN 1822-1:2019-05 pkt. 5 i 6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Filtr powietrza Jednorodność materiału filtrującego (badanie przecieków) oraz szczelność mocowania filtra\nZakres:\nstężenie masowe cząstek\nZakres (0,0003 - 100) μg/l\nMetoda pomiaru fotometrem liniowym PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6 Filtr powietrza Jednorodnosc materialu filtrujacego (badanie przeciekow) oraz szczelnosc mocowania filtra\nZakres:\nstezenie masowe czastek\nZakres (0,0003 - 100) μg/l\nMetoda pomiaru fotometrem liniowym PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i zalacznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6","categories":["materials"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air filter Homogeneity of the filter medium (leak test) and tightness of the filter mounting Measurement method using a linear photometer particle mass concentration Range PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6","parameters_zh":[{"name":"stężenie masowe cząstek"},{"name":"范围","range":"(0,0003 - 100) μg/l"}],"search_zh":"范围 PN-EN ISO 14644-3:2020-03 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6"},{"_id":"6a5dc9c6f1c10c8ce82604a4","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Wentylacja","test_object_en":"Ventilation","methodology":"Prędkość powietrza","methodology_en":"Air velocity","parameters":[{"name":"Zakres","range":"(0,2 - 40) m/s"},{"name":"Strumień objętości powietrza do określania ilości wymian"},{"name":"Zakres","range":"(50 - 2000) m3/godz."}],"parameters_en":[{"name":"Range","range":"(0,2 - 40) m/s"},{"name":"Air volume flow rate for determining the number of air changes"},{"name":"Range","range":"(50 - 2000) m3/godz."}],"technique":"Metoda pomiaru pośredniego; Metoda pomiaru bezpośredniego","techniques":["Metoda pomiaru pośredniego","Metoda pomiaru bezpośredniego"],"technique_en":"Indirect measurement method; Direct measurement method","computed":[],"computed_en":[],"activity":"Prędkość powietrza\nZakres:\nZakres (0,2 - 40) m/s\nStrumień objętości powietrza do określania ilości wymian\nZakres (50 - 2000) m3/godz.\nMetoda pomiaru pośredniego; Metoda pomiaru bezpośredniego","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wentylacja Prędkość powietrza\nZakres:\nZakres (0,2 - 40) m/s\nStrumień objętości powietrza do określania ilości wymian\nZakres (50 - 2000) m3/godz.\nMetoda pomiaru pośredniego; Metoda pomiaru bezpośredniego PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2 Wentylacja Predkosc powietrza\nZakres:\nZakres (0,2 - 40) m/s\nStrumien objetosci powietrza do okreslania ilosci wymian\nZakres (50 - 2000) m3/godz.\nMetoda pomiaru posredniego; Metoda pomiaru bezposredniego PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i zalacznik B.2","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ventilation Air velocity Indirect measurement method; Direct measurement method Range Air volume flow rate for determining the number of air changes Range PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2","methodology_zh":"空气流速","parameters_zh":[{"name":"范围","range":"(0,2 - 40) m/s"},{"name":"Strumień objętości powietrza do określania ilości wymian"},{"name":"范围","range":"(50 - 2000) m3/godz."}],"search_zh":"空气流速 范围 范围 PN-EN ISO 14644-3:2020-03 pkt. 4.2.2 i załącznik B.2"},{"_id":"6a5dc9c6f1c10c8ce82604a5","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Pomieszczenia czyste i komory laminarne","test_object_en":"Cleanrooms and laminar flow cabinets","methodology":"Przenikalność - stężenie masowe cząstek","methodology_en":"Penetration - mass concentration of particles","parameters":[{"name":"Zakres","range":"(0,0003 - 100) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,0003 - 100) μg/l"}],"technique":"Metoda pomiaru fotometrem liniowym","techniques":["Metoda pomiaru fotometrem liniowym"],"technique_en":"Measurement method using a linear photometer","computed":[],"computed_en":[],"activity":"Przenikalność - stężenie masowe cząstek\nZakres (0,0003 - 100) μg/l\nMetoda pomiaru fotometrem liniowym","reference":"PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8","norm_bases":["PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia czyste i komory laminarne Przenikalność - stężenie masowe cząstek\nZakres (0,0003 - 100) μg/l\nMetoda pomiaru fotometrem liniowym PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8 Pomieszczenia czyste i komory laminarne Przenikalnosc - stezenie masowe czastek\nZakres (0,0003 - 100) μg/l\nMetoda pomiaru fotometrem liniowym PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i zalacznik B.8","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cleanrooms and laminar flow cabinets Penetration - mass concentration of particles Measurement method using a linear photometer Range PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8","parameters_zh":[{"name":"范围","range":"(0,0003 - 100) μg/l"}],"search_zh":"范围 PN-EN ISO 14644-3:2020-03 pkt. 4.2.8 i załącznik B.8"},{"_id":"6a5dc9c6f1c10c8ce82604a6","lab_id":"69ad52a3de79e566650fb17d","country":"PL","accr_number":"AB 243","accr_body":"PCA","test_object":"Sprężone powietrze i gazy techniczne (azot i tlen)","test_object_en":"Compressed air and industrial gases (nitrogen and oxygen)","methodology":"Czystość - zawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm","methodology_en":"Cleanliness - particle number concentration for diameters: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm","parameters":[{"name":"(od 1 do 349.999.965) cząstek/m3"}],"parameters_en":[{"name":"(from 1 to 349.999.965) particles/m3"}],"technique":"Metoda pomiaru licznikiem cząstek","techniques":["Metoda pomiaru licznikiem cząstek"],"technique_en":"Measurement method using a particle counter","computed":[],"computed_en":[],"activity":"Czystość - zawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) cząstek/m3\nMetoda pomiaru licznikiem cząstek","reference":"Procedura 0100 edycja 13 z dnia 20.03.2020 r.","norm_bases":["Procedura 0100 edycja 13 z dnia 20.03.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sprężone powietrze i gazy techniczne (azot i tlen) Czystość - zawartość liczbowa cząstek o średnicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) cząstek/m3\nMetoda pomiaru licznikiem cząstek Procedura 0100 edycja 13 z dnia 20.03.2020 r. Sprezone powietrze i gazy techniczne (azot i tlen) Czystosc - zawartosc liczbowa czastek o srednicach: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm\n(od 1 do 349.999.965) czastek/m3\nMetoda pomiaru licznikiem czastek Procedura 0100 edycja 13 z dnia 20.03.2020 r.","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Compressed air and industrial gases (nitrogen and oxygen) Cleanliness - particle number concentration for diameters: (0,1; 0,2; 0,3; 0,5; 1,0; 5,0) μm Measurement method using a particle counter (from 1 to 349.999.965) particles/m3 Procedura 0100 edycja 13 z dnia 20.03.2020 r.","parameters_zh":[{"name":"(1 至 349.999.965) 个粒子/m3"}],"search_zh":"粒子计数器测量法 (1 至 349.999.965) 个粒子/m3 Procedura 0100 edycja 13 z dnia 20.03.2020 r.","technique_zh":"粒子计数器测量法"}],"has_pdf":true}