🇵🇱 GDAŃSKIE WODOCIĄGI Sp. z o.o. PL

PCA AB 216 • Gdańsk, Poland • 133 methods

Water & wastewaterMicrobiologyMaterials & polymers

GDAŃSKIE WODOCIĄGI Sp. z o.o. is a laboratory accredited by PCA under number AB 216 (Gdańsk, Poland). Its accreditation scope covers 133 test methods in the following areas: Water & wastewater, Microbiology, Materials & polymers. Test objects include: Water, water intended for human consumption, Wastewater, Sewage sludge, Water, water intended for human consumption, wastewater. Most frequently used techniques: Titrimetric method, Spectrophotometric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 216
  • Methods in scope: 133
  • Types of test objects: 17
  • Techniques used: 35
  • City: Gdańsk, Poland
Accreditation number
AB 216
Accreditation body
PCA
Address
WYDZIAŁ LABORATORIUM, ul. Wałowa 46, 80-858 Gdańsk
City
Gdańsk, Poland

What this laboratory tests (17)

Analytical techniques used (35)

Accreditation scope — test methods (133)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing (including sensory) Temperature of water/of the water sample taken
Range (0,0 – 50,0) °C
PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
2 Swimming pool water Sampling for chemical and physical testing Temperature of water/of the water sample taken
Range (0,0 – 50,0) °C
PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
3 Water Sampling for chemical and physical testing Temperature of water/of the water sample taken
Range (0,0 – 50,0) °C
PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3 | PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
4 Water (including swimming pool water, bathing water), water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6
5 Water (including swimming pool water), water intended for human consumption Total chlorine concentration
Range (0,02 – 5,0) mg/l Free chlorine concentration Range (0,02 – 5,0) mg/l Combined chlorine (calculated)
Colorimetric method GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167
6 Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing
Temperature of wastewater/collected wastewater sample Range (0,0 – 50,0) °C
Manual method PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
7 Wastewater Sampling for chemical and physical testing
Wastewater temperature Range (5,0 – 30,0) °C
Automatic method PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
8 Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
9 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10
10 Water, water intended for human consumption Permanganate index
Range (0,5 – 20) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
11 Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999
12 Water, water intended for human consumption Turbidity
Range (0,2 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
13 Water, water intended for human consumption Taste threshold number (TFN)
Range 1 – 2
Simplified paired method, non-forced choice GdW/SL/PB-44 wyd.09 z dnia 01.09.2023
14 Water, water intended for human consumption Odour threshold number (TON)
Range 1 – 2
Simplified paired method, non-forced choice GdW/SL/PB-44 wyd.09 z dnia 01.09.2023
15 Water, water intended for human consumption Odour threshold number (TON)
Range 1 – 20
Full paired method, non-forced choice GdW/SL/PB-44 wyd.09 z dnia 01.09.2023
16 Water, water intended for human consumption Dry residue
Range (1 – 2500) mg/l
Gravimetric method PN-78/C-04541
17 Water, water intended for human consumption Total hardness
Range (5 – 800) mg/l CaCO3 Range (0,1 – 16) mval/l Range (0,05 – 8) mmol/l
Titrimetric method PN-ISO 6059:1999
18 Water, water intended for human consumption Carbonate, non-carbonate hardness (calculated) GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025
19 Water, water intended for human consumption Calcium concentration
Range (2 – 320) mg/l Calcium hardness Range (5 – 800) mg/l CaCO3
Titrimetric method PN-ISO 6058:1999
20 Water, water intended for human consumption Ammonium ion concentration
Range (0,05 – 51,5) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
21 Water, water intended for human consumption Total and mineral alkalinity
Range (0,4 – 20) mmol/l Range (0,4 – 20) mval/l Range (20 – 1000) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
22 Water, water intended for human consumption Bicarbonate concentration (calculated) GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025
23 Water, water intended for human consumption Colour
Range (2 – 200) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
24 Water, water intended for human consumption Content of organic substances absorbing UV radiation (absorbance)
Range (0,050 – 1,80) A Range (0,010 – 0,360) cm-1
Spectrophotometric method GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025
25 Swimming pool water Permanganate index
Range (0,5 – 20) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
26 Swimming pool water Turbidity
Range (0,2 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
27 Swimming pool water pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
28 Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD5
Range (0,6 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 z wył. p. 7.2 | ISO 17289 :2014
29 Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD5
Range (3 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
30 Water, water intended for human consumption, wastewater Chloride concentration
Range (5 – 5000) mg/l
Titrimetric method PN-ISO 9297:1994
31 Water, water intended for human consumption, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
32 Water, water intended for human consumption, wastewater o-phosphate concentration
Range (0,04 – 40) mg/l PO4
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010
33 Water, water intended for human consumption, wastewater Electrical conductivity
Range (5 – 10000) μS/cm
Conductometric method PN-EN 27888:1999
34 Water, wastewater Concentration of anionic surfactants (detergents)
Range (0,1 – 100) mg/l
Spectrophotometric method PN-EN 903:2002
35 Water, wastewater Total dissolved solids concentration
Range (1 – 2500) mg/l
Gravimetric method PN-78/C-04541
36 Water, wastewater Phenol index
Range (0,002 – 0,500) mg/l
Spectrophotometric method PN-ISO 6439:1994
37 Water Chemical oxygen demand - COD-Cr
Range (5 – 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
38 Water Concentration of organic substances extractable with petroleum ether
Range (0,8 – 10,0) mg/l
Gravimetric method PN-86/C-04573.01
39 Water Total suspended solids (TSS)
Range (2,0 – 100) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
40 Water Kjeldahl nitrogen concentration
Range (1 – 50) mg/l
Titrimetric method PN-EN 25663:2001
41 Wastewater Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
42 Wastewater Total and mineral alkalinity
Range (0,4 – 20) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
43 Wastewater Concentration of organic substances extractable with petroleum ether
Range (0,8 – 500) mg/l
Gravimetric method PN-86/C-04573.01
44 Wastewater Ammonium nitrogen concentration
Range (0,5 – 250) mg/l
Titrimetric method PN-ISO 5664:2002
45 Wastewater Kjeldahl nitrogen concentration
Range (1 – 500) mg/l
Titrimetric method PN-EN 25663:2001
46 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14
47 Wastewater Hydrogen sulfide and sulfide concentration
Range (0,04 – 20) mg/l
Titrimetric method PN-82/C-04566.03
48 Wastewater Chemical oxygen demand - COD-Cr
Range (5 – 20000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
49 Wastewater (including rainwater and snowmelt water) pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
50 Wastewater (including rainwater and snowmelt water) Electrical conductivity
Range (5 – 10000) μS/cm
Conductometric method PN-EN 27888:1999
51 Wastewater (including rainwater and snowmelt water) Total suspended solids, Range(2,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
52 Wastewater (including rainwater and snowmelt water) Chemical oxygen demand - COD-Cr
Range (5 – 20000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
53 Sewage sludge Ammonium nitrogen content
Range (30 – 2000) mg/kg os. uwod. Range (0,1 – 3,0) % N w s. m. osadu
Titrimetric method GdW/SL/PB-36 wyd.09 z dnia 01.09.2023
54 Sewage sludge Total Kjeldahl nitrogen content
Range (30 – 5000) mg/kg os. uwod. Range (0,5 – 10,0) % N w s. m. osadu
Titrimetric method GdW/SL/PB-36 wyd.09 z dnia 01.09.2023
55 Sewage sludge Total phosphorus content
Range (0,01 – 10,0) % P w os. suchym
Spectrophotometric method GdW/SL/PB-35 wyd.08 z dnia 01.09.2023
56 Sewage sludge pH
Range 3,0 – 10,0
Potentiometric method PN-EN 12176:2004
57 Water, water intended for human consumption Mercury concentration
Range (0,0005 – 0,050) mg/l
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 z wył. p.6
58 Water, water intended for human consumption Selenium concentration
Range (0,001 – 0,100) mg/l
Hydride generation atomic absorption spectrometry (HGAAS) PN-ISO 9965:2001
59 Water, water intended for human consumption Antimony concentration
Range (0,001 – 0,100) mg/l
Hydride generation atomic absorption spectrometry (HGAAS) GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025
60 Water, water intended for human consumption Concentration of total (TOC) and dissolved (DOC) organic carbon
Range (0,5 – 20) mg/l
Spectrometry method in the infrared range (IR) P N - EN 1484:1999
61 Water, water intended for human consumption Sodium concentration
Range (0,05 – 500) mg/l Potassium concentration Range (0,05 – 100) mg/l
Flame atomic emission spectrometry (FAES) PN-ISO 9964-3:1994
62 Water, water intended for human consumption Metal concentrations
copper (0,004 – 0,500) mg/l cadmium (0,0003 – 0,500) mg/l lead (0,002 – 0,500) mg/l chromium (0,0004 – 0,500) mg/l nickel (0,003 – 0,500) mg/l silver (0,003 – 0,500) mg/l arsenic (0,003 – 0,500) mg/l manganese (0,005 – 2,00) mg/l vanadium (0,004 – 0,500) mg/l aluminium (0,02 – 2,00) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
63 Wastewater Metal concentrations
zinc (0,1– 10) mg/l iron (0,2 – 10) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 metoda A
64 Wastewater Metal concentrations
copper (0,004 – 0,500) mg/l cadmium (0,0003 – 0,500) mg/l lead (0,002 – 0,500) mg/l chromium (0,0004 – 0,500) mg/l nickel (0,003 – 0,500) mg/l silver (0,003 – 0,500) mg/l arsenic (0,003 – 0,500) mg/l vanadium (0,004 – 0,500) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
65 Wastewater Mercury concentration
Range (0,001 – 0,050) mg/l
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 z wył. p.6
66 Wastewater (including rainwater and snowmelt water) Total organic carbon concentration (TOC)
Range (3 – 1000) mg/l
Spectrophotometric method GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386
67 Wastewater (including rainwater and snowmelt water) Element concentration
antimony (1,0 – 10000) μg/l arsenic (1,0 – 10000) μg/l barium (1,0 – 10000) μg/l beryllium (1,0 – 10000) μg/l boron (50 – 10000) μg/l chromium (1,0 – 10000) μg/l tin (1,0 – 10000) μg/l zinc (50 – 50000) μg/l phosphorus (0,05 – 100) mg/l aluminium (50 – 10000) μg/l cadmium (1,0 – 10000) μg/l cobalt (1,0 – 10000) μg/l manganese (5,0 – 50000) μg/l copper (5,0 – 10000) μg/l molybdenum (1,0 – 10000) μg/l nickel (5,0 – 10000) μg/l lead (1,0 – 10000) μg/l mercury (0,50 – 200) μg/l selenium (5,0 – 10000) μg/l silver (5,0 – 10000) μg/l strontium (1,0 – 10000) μg/l thallium (1,0 – 10000) μg/l titanium ( 1,0 – 10000) μg/l uranium (1,0 – 10000) μg/l vanadium (5,0 – 10000) μg/l iron (50 – 50000) μg/l
Inductively coupled plasma mass spectrometry method (ICP-MS) PN-EN ISO 17294-2:2024-04
68 Water, water intended for human consumption Element concentration
calcium (0,05 – 500) mg/l magnesium (0,05 – 100) mg/l sodium (0,05 – 500) mg/l potassium (0,05 – 100) mg/l boron (0,05 – 10) mg/l aluminium (0,01 – 10) mg/l manganese (0,005 – 100) mg/l copper (0,005 – 10) mg/l iron (0,01 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
69 Water, water intended for human consumption Total hardness (calculated) PN-EN ISO 11885:2009
70 Water, water intended for human consumption Element concentration
antimony (0,10 – 5000) μg/l arsenic (1,0 – 5000) μg/l barium (1,0 – 5000) μg/l beryllium (0,10 – 5000) μg/l boron (10 – 5000) μg/l chromium (0,10 – 5000) μg/l tin (1,0 – 5000) μg/l zinc (10 – 50000) μg/l phosphorus (0,05 – 5,0) mg/l aluminium (10 – 5000) μg/l cadmium (0,10 – 5000) μg/l cobalt (0,10 – 5000) μg/l magnesium (0,05 – 500) mg/l manganese (1,0 – 50000) μg/l copper (1,0 – 5000) μg/l molybdenum (1,0 – 5000) μg/l nickel (1,0 – 5000) μg/l lead (1,0 – 5000) μg/l potassium (0,05 – 500) mg/l mercury (0,10 – 50) μg/l selenium (1,0 – 5000) μg/l silver (1,0 – 5000) μg/l sodium (0,05 – 500) mg/l strontium (1,0 – 5000) μg/l thallium (0,10 – 5000) μg/l titanium (1,0 – 5000) μg/l uranium (0,10 – 5000) μg/l vanadium (1,0 – 5000) μg/l calcium (0,05 – 500) mg/l iron (10 – 50000) μg/l
Inductively coupled plasma mass spectrometry method (ICP- PN-EN ISO 17294-2:2024-04
71 Water, water intended for human consumption MS) PN-EN ISO 17294-2:2024-04
72 Water Total phosphorus concentration
Range (0,05 – 5) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
73 Water, wastewater Element concentration
arsenic (0,05 – 2) mg/l barium (0,005 – 5) mg/l boron (0,05 – 10) mg/l chromium (0,005 – 10) mg/l tin (0,03 – 2) mg/l zinc (0,01 – 10) mg/l aluminium (0,01 – 10) mg/l cadmium (0,005 – 10) mg/l cobalt (0,005 – 10) mg/l manganese (0,005 – 100) mg/l copper (0,005 – 10) mg/l molybdenum (0,005 – 10) mg/l nickel (0,01 – 10) mg/l lead (0,05 – 10) mg/l silver (0,005 – 10) mg/l vanadium (0,005 – 10) mg/l iron (0,01 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
74 Wastewater (including rainwater and snowmelt water) Total phosphorus concentration
Range (0,05 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
75 Sewage sludge Mercury content
Range (0,1 – 50) mg/kg
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 54321:2021-07 | PN-EN 16175-1:2017-02
76 Sewage sludge Element concentration
copper (2 – 4000) mg/kg zinc (5 – 10000) mg/kg cadmium (2 – 100) mg/kg lead (5 – 3000) mg/kg chromium (2 – 5000) mg/kg nickel (2 – 1000) mg/kg calcium (25 – 200000) mg/kg Range (0,0025 – 20) % s.m. magnesium (25 - 100000) mg/kg (0,0025 – 10) % d.m. total phosphorus (5 – 200000) mg/kg (0,0005 – 20) % d.m.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 | PN EN ISO 54321:2021
77 Water, water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH)
fluoranthene (2,0 – 100) ng/l benzo(b)fluoranthene (2,0 – 100) ng/l benzo(k)fluoranthene (2,0 – 100) ng/l benzo(a)pyrene (2,0 – 100) ng/l benzo(ghi)perylene (2,0 – 100) ng/l indeno(1,2,3-c,d)pyrene (2,0 – 100) ng/l
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023
78 Water, water intended for human consumption Sum of PAH (calculated) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023
79 Water, water intended for human consumption Acrylamide concentration
Range (0,050 – 1,0) μg/l
Gas chromatography with electron capture detection (GC-ECD) GdW/SL/PB-70 wyd.05 z dnia 01.09.2023
80 Water, water intended for human consumption Epichlorohydrin concentration
Range (0,050 – 1,0) μg/l
Gas chromatography with mass spectrometry detection (GC-MS) GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025
81 Water, water intended for human consumption Concentration of triazine and urea pesticides
atrazine (5,0 –100) ng/l desethylatrazine (5,0 –100) ng/l simazine (5,0 –100) ng/l cyanazine (5,0 –100) ng/l sebuthylazine (5,0 –100) ng/l terbuthylazine (5,0 –100) ng/l metoxuron (5,0 –100) ng/l hexazinone (5,0 –100) ng/l metabenzthiazuron (5,0 –100) ng/l chlortoluron (5,0 –100) ng/l monolinuron (5,0 –100) ng/l diuron (5,0 –100) ng/l isoproturon (5,0 –100) ng/l metobromuron (5,0 –100) ng/l metazachlor (5,0 –100) ng/l linuron (5,0 –100) ng/l metolachlor (5,0 –100) ng/l
Liquid chromatography with tandem mass spectrometry detection (LC MS-MS) GdW/SL/PB-73 wyd.03 z dnia 01.09.2023
82 Water, water intended for human consumption Anion concentrations
bromates (0,003 – 0,025) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 15061:2003
83 Water, water intended for human consumption Anion concentrations
chlorites (0,010 – 6,0) mg/l chlorates (0,010 – 6,0) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
84 Water, water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08
85 Water, water intended for human consumption Anion concentrations
bromides (0,010 – 4,0) mg/l chlorides (1,0 – 5000) mg/l fluorides (0,020 – 10,0) mg/l nitrates (0,20 – 50,0) mg/l nitrites (0,003 – 6,00) mg/l orthophosphates (0,020 – 25,0) mg/l sulfates (1,0 – 3500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC 2012
86 Water, water intended for human consumption Haloacetic acid (HAA) concentration
monochloroacetic acid MCAA Range (5,0 – 100) ng/l monobromoacetic acid MBAA (5,0 – 100 ng/l) dichloroacetic acid DCAA (5,0 – 100 ng/l) dibromoacetic acid DBAA (5,0 – 100 ng/l) trichloroacetic acid TCAA (5,0 – 100 ng/l)
Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024
87 Water, water intended for human consumption Sum of HAA (calculated) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024
88 Water, water intended for human consumption Bisphenol-A concentration
Range (0,05 – 2,5) μg/l
Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025
89 Water, water intended for human consumption Concentration of perfluoroalkyl and perfluoroalkyl sulfonic acids (PFAS)
perfluorobutanoic acid (PFBA) Range (5,0 – 100 ng/l) perfluoropentanoic acid (PFPeA) (5,0 – 100 ng/l) perfluorohexanoic acid (PFHxA) (5,0 – 100 ng/l) perfluoroheptanoic acid (PFHpA) (5,0 – 100 ng/l) perfluorooctanoic acid (PFOA) (5,0 – 100 ng/l) perfluorononanoic acid (PFNA) (5,0 – 100 ng/l) perfluorodecanoic acid (PFDA) (5,0 – 100 ng/l) perfluoroundecanoic acid (PFUnDA) (5,0 – 100 ng/l) perfluorododecanoic acid (PFDoDA) (5,0 – 100 ng/l) perfluorotridecanoic acid (PFTrDA) (5,0 – 100 ng/l) perfluorobutanesulfonic acid (PFBS) (5,0 – 100 ng/l) perfluoropentanesulfonic acid (PSPS) (5,0 – 100 ng/l) perfluorohexanesulfonic acid (PFHxS) (5,0 – 100 ng/l) perfluoroheptanesulfonic acid (PFHpS) (5,0 – 100 ng/l) perfluorooctanesulfonic acid (PFOS) (5,0 – 100 ng/l) perfluorononanesulfonic acid (PFNS) (5,0 – 100 ng/l) perfluorodecanesulfonic acid (PFDS) (5,0 – 100 ng/l) perfluoroundecanesulfonic acid (PFUnDS) (5,0 – 100 ng/l) perfluorododecanesulfonic acid (PFDoDS) (5,0 – 100 ng/l) perfluorotridecanesulfonic acid (PFTrDS) (5,0 – 100 ng/l)
Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024
90 Water, water intended for human consumption Sum of PFAS (calculated) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024
91 Swimming pool water Anion concentrations
nitrates (0,20 – 50,0) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC 2012
92 Wastewater Anion concentrations
chlorides (1,0 – 5000) mg/l fluorides (0,020 – 10,0) mg/l nitrates (0,20 – 250) mg/l nitrites (0,003 – 60,0) mg/l orthophosphates (0,020 – 25,0) mg/l sulfates (1,0 – 5000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC 2012
93 Wastewater Concentration of perfluoroalkyl and perfluoroalkyl sulfonic acids (PFAS)
perfluorobutanoic acid (PFBA) Range (5,0 – 100 ng/l) perfluoroheptanoic acid (PFHpA) (5,0 – 100 ng/l) perfluorooctanoic acid (PFOA) (5,0 – 100 ng/l) perfluorononanoic acid (PFNA) (5,0 – 100 ng/l) perfluorodecanoic acid (PFDA) (5,0 – 100 ng/l) perfluoroundecanoic acid (PFUnDA) (5,0 – 100 ng/l) perfluorododecanoic acid (PFDoDA) (5,0 – 100 ng/l) perfluorotridecanoic acid (PFTrDA) (5,0 – 100 ng/l) perfluoropentanesulfonic acid (PSPS) (5,0 – 100 ng/l) perfluorohexanesulfonic acid (PFHxS) (5,0 – 100 ng/l) perfluoroheptanesulfonic acid (PFHpS) (5,0 – 100 ng/l) perfluorooctanesulfonic acid (PFOS) (5,0 – 100 ng/l) perfluorononanesulfonic acid (PFNS) (5,0 – 100 ng/l) perfluorodecanesulfonic acid (PFDS) (5,0 – 100 ng/l) perfluoroundecanesulfonic acid (PFUnDS) (5,0 – 100 ng/l) perfluorododecanesulfonic acid (PFDoDS) (5,0 – 100 ng/l) perfluorotridecanesulfonic acid (PFTrDS) (5,0 – 100 ng/l)
Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024
94 Wastewater Sum of PFAS (calculated) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024
95 Water, water intended for human consumption, wastewater (including rainwater and snowmelt water) Mineral oil index
Range (0,10 – 100) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
96 Water, wastewater Concentration of polycyclic aromatic hydrocarbons:
Benzo(b)fluoranthene (10,0 – 1000) ng/l Benzo(k)fluoranthene (10,0 – 1000) ng/l Benzo(a)pyrene (10,0 – 1000) ng/l Dibenzo(a,h)anthracene Range (10,0 – 1000) ng/l Benzo(g,h,i)perylene (10,0 – 1000) ng/l Indeno (1,2,3-c,d)piren (10,0 – 1000) ng/l Fluoranthene (10,0 – 1000) ng/l Chrysene (10,0 – 1000) ng/l
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) GdW/SL/PB-15wyd.06 z dnia 01.09.2023
97 Water, wastewater Sum of PAH (calculated) GdW/SL/PB-15wyd.06 z dnia 01.09.2023
98 Water, water intended for human consumption Concentration of chlorinated organic compounds
hexachlorobenzene Range (5,0 – 100) ng/l lindane (gamma HCH) (5,0 – 100) ng/l aldrin (5,0 – 100) ng/l dieldrin (5,0 – 100) ng/l endrin (5,0 – 100) ng/l alpha- Endosulfan (5,0 – 100) ng/l beta-Endosulfan (5,0 – 100) ng/l p,p’-DDT (5,0 – 100) ng/l alpha-HCH (5,0 – 100) ng/l beta-HCH (5,0 – 100) ng/l delta-HCH (5,0 – 100) ng/l Heptachlor (5,0 – 100) ng/l Isodrin (5,0 – 100) ng/l Heptachlor epoxide (5,0 – 100) ng/l p,p’-DDE (5,0 – 100) ng/l p,p’-DDD (5,0 – 100) ng/l Endrin aldehyde (5,0 – 100) ng/l Endosulfan sulfate (5,0 – 100) ng/l p,p’-DMDT - (methoxychlor) (5,0 – 100) ng/l pentachlorobenzene (5,0 – 100) ng/l trifluralin (5,0 – 100) ng/l pendimethalin (5,0 – 100) ng/l 1,2,4-trichlorobenzene (10,0 – 100) ng/l 1,2,3- trichlorobenzene (10,0 – 100) ng/l 1,3,5 - trichlorobenzene (10,0 – 100) ng/l
Gas chromatography with electron capture detection (GC-ECD) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023
99 Water, water intended for human consumption Concentration of total pesticides (calculated) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023
100 Water, water intended for human consumption Trichlorobenzene concentration (sum of isomers) (calculated) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023
101 Water, water intended for human consumption Concentration
trans-1,2-dichloroethene Range (0,1 – 50,0) μg/l cis-1,2-dichloroethene (0,1 – 50,0) μg/l 1,2-dichlorobenzene (0,1 – 50,0) μg/l 1,3-dichlorobenzene (0,1 – 50,0) μg/l 1,4-dichlorobenzene (0,1 – 50,0) μg/l chlorobenzene (0,1 – 50,0) μg/l
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) PN-EN ISO 15680:2008
102 Water Polychlorinated biphenyls (PCB) concentration
PCB-28 (5,0 – 100) ng/l PCB-52 (5,0 – 100) ng/l PCB-101 (5,0 – 100) ng/l PCB-118 (5,0 – 100) ng/l PCB-138 (5,0 – 100) ng/l PCB-153 (5,0 – 100) ng/l PCB-180 (5,0 – 100)) ng/l
Gas chromatography with electron capture detection (GC-ECD) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023
103 Water Concentration of total PCB (calculated) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023
104 Water (including swimming pool water), water intended for human consumption, wastewater Concentration of monocyclic aromatic hydrocarbons and volatile organochlorine compounds
chloroform ( trichloromethane) Range (0,5 – 100,0) μg/l bromodichloromethane (0,1 – 100,0) μg/l dibromochloromethane (0,1 – 100,0) μg/l bromoform (tribromomethane) (0,1 – 100,0) μg/l
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS) PN-EN ISO 15680:2008
105 Water (including swimming pool water), water intended for human consumption, wastewater Concentration of total THM (chloroform, bromodichloromethane, dibromochloromethane, bromoform) (calculated) PN-EN ISO 15680:2008
106 Wastewater Concentration of monocyclic aromatic hydrocarbons and volatile organochlorine compounds
chloroform ( trichloromethane) Range (0,5 – 50,0) μg/l bromodichloromethane (0,1 – 50,0) μg/l dibromochloromethane (0,1 – 50,0) μg/l bromoform (tribromomethane) (0,1 – 50,0) μg/l
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS) PN-EN ISO 15680:2008
107 Water, water intended for human consumption, wastewater Concentration
carbon tetrachloride (0,05 – 5,00) μg/l trichloroethene (0,1 – 50,0) μg/l tetrachloroethene (0,1 – 50,0) μg/l
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) PN-EN ISO 15680:2008
108 Water, water intended for human consumption, wastewater Concentration of the sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 15680:2008
109 Water, water intended for human consumption, wastewater Monocyclic aromatic hydrocarbons (BTX) concentration
Range 1,2-dichloroetan (0,1 – 50,0) μg/l benzene (0,1 – 50,0) μg/l vinyl chloride (0,1 – 5,00 ) μg/l dichloromethane (0,5 – 50,0) μg/l hexachlorobutadiene (0,1 – 50,0) μg/l toluene (0,1 – 50,0) μg/l ethylbenzene (0,1 – 50,0) μg/l o-xylene (0,1 – 50,0) μg/l m+p-xylene (0,2 – 100,0) μg/l styrene (0,1 – 50,0) μg/l isopropylbenzene (0,1 – 50,0) μg/l
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) PN-EN ISO 15680:2008
110 Water, water intended for human consumption, wastewater Sum of BTX ( Benzene, Toluene, Xylene) (calculated) PN-EN ISO 15680:2008
111 Water, water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
112 Water, water intended for human consumption MPN of Escherichia coli and coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
113 Water, water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
114 Water, water intended for human consumption Count of microorganisms at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004
115 Water (including swimming pool water), water intended for human consumption Count of microorganisms at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
116 Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella
Matrix A; Procedure 5; Medium A-BCYE Matrix A; Procedure 6,7; Medium C-GVPC Matrix B; Procedure 6,7; Medium C-GVPC
Membrane filtration method PN-EN ISO 11731:2017-08+ Ap1:2019-12
117 Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
118 Water (including swimming pool water, bathing water), water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
119 Water (including bathing water), water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
120 Water (including swimming pool water) Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3: 2000 Załącznik A
121 Water (including bathing water) MPN of intestinal enterococci Miniaturized method PN-EN ISO 7899-1:2002
122 Water (including bathing water) MPN Escherichia coli Miniaturized method PN-EN ISO 9308-3:2002
123 Wastewater Biochemical oxygen demand - BOD5
Range (0,6 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
124 Wastewater Biochemical oxygen demand - BOD5
Range (3,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
125 Wastewater Chemical oxygen demand COD-Cr
Range (15 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
126 Wastewater pH
Range 3,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
127 Wastewater Electrical conductivity
Range (5 – 50000) μS/cm
Conductometric method PN-EN 27888:1999
128 Wastewater Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
129 Wastewater Ammonium nitrogen concentration
Range (0,5 – 250) mg/l
Titrimetric method PN-ISO 5664:2002
130 Wastewater Free and combined cyanide concentration
Range (0,005 – 1,0) mg/l
Spectrophotometric method P N-80/C-04603.01
131 Sewage sludge pH
Range 3,0 – 10,0
Potentiometric method PN-EN 12176:2004
132 Sewage sludge Dry matter / water content
Range (0,10 – 99,9) %
Gravimetric method PN-EN 12880:2004
133 Sewage sludge Loss on ignition of dry matter (LOI)
Range (0,10 – 99,9) %
Gravimetric method PN-EN 12879:2004

Reference standards (81)

GdW/SL/PB-15wyd.06 z dnia 01.09.2023
GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025
GdW/SL/PB-18 wyd.11 z dnia 01.09.2023
GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023
GdW/SL/PB-35 wyd.08 z dnia 01.09.2023
GdW/SL/PB-36 wyd.09 z dnia 01.09.2023
GdW/SL/PB-44 wyd.09 z dnia 01.09.2023
GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167
GdW/SL/PB-70 wyd.05 z dnia 01.09.2023
GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025
GdW/SL/PB-73 wyd.03 z dnia 01.09.2023
GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024
GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024
GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025
GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025
GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025
GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025
GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386
ISO 17289 :2014
P N - EN 1484:1999
P N-80/C-04603.01
PN EN ISO 54321:2021
PN-73/C-04576.14
PN-78/C-04541
PN-82/C-04566.03
PN-86/C-04573.01
PN-C-04554-4:1999
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 16175-1:2017-02
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wył. p. 7.2
PN-EN 25663:2001
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10304-1:2009+AC 2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+ Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 12846:2012 z wył. p.6
PN-EN ISO 14189:2016-10
PN-EN ISO 15061:2003
PN-EN ISO 15586:2005
PN-EN ISO 15680:2008
PN-EN ISO 16266:2009
PN-EN ISO 17294-2:2024-04
PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6
PN-EN ISO 54321:2021-07
PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-1:2002
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9308-3:2002
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3
PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A
PN-ISO 9297:1994
PN-ISO 9964-3:1994
PN-ISO 9965:2001
PN-Z-11001-3: 2000 Załącznik A