{"lab":{"_id":"69ad52a3de79e566650fb173","accr_number":"AB 216","country":"PL","accr_body":"PCA","address":"WYDZIAŁ LABORATORIUM, ul. Wałowa 46, 80-858 Gdańsk","categories":["water","materials","microbiology"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":133,"name":"GDAŃSKIE WODOCIĄGI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_216.pdf"],"scope_summary":"","search_text":"gdańskie wodociągi sp. z o.o. wydział laboratorium, ul. wałowa 46, 80-858 gdańsk other water pharma electronics materials food microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:06.134Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:06.134Z","location":{"type":"Point","coordinates":[18.6466,54.352]},"email_confidence":"high","email_mx":true,"email_source":"https://www.gdanskiewodociagi.pl/Katalogus%C5%82ug/badaniewodyisciekow.aspx","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P ; N/30/P; N/32/P","pl":"Badania właściwości fizycznych wody i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments"},{"codes":"Q/28/P; Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"26","date":"05.11.2025"},"parse_date":"2026-07-20T19:34:23.444Z","parse_source":"script-pdfplumber","map_coord":[54.357804,18.65685],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":133,"materials":6,"microbiology":6,"petro":1},"category_scores":{"water":121.16,"materials":0.25,"microbiology":0.25,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5e783f4cc76d93cba39e52","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) Temperatura wody/pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing (including sensory) Temperature of water/of the water sample taken","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) Temperatura wody/pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","norm_bases":["PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) Temperatura wody/pobranej próbki wody\nZakres (0,0 – 50,0) °C PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) Temperatura wody/pobranej probki wody\nZakres (0,0 – 50,0) °C PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory) Temperature of water/of the water sample taken Range PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"生活饮用水 范围 PN-ISO 5667-5:2017-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","test_object_zh":"生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e53","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water/of the water sample taken","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","norm_bases":["PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (0,0 – 50,0) °C PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura wody/pobranej probki wody\nZakres (0,0 – 50,0) °C PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zal. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Sampling for chemical and physical testing Temperature of water/of the water sample taken Range PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"游泳池水 用于化学与物理检验的采样 水/所采水样的温度 范围 PN-ISO 5667-5:2017-10 GdW/SL/PO-03 zał. ZK-09 G wyd.04 z dnia 01.09.2023 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","test_object_zh":"游泳池水","methodology_zh":"用于化学与物理检验的采样 水/所采水样的温度"},{"_id":"6a5e783f4cc76d93cba39e54","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water/of the water sample taken","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3 | PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3","PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (0,0 – 50,0) °C PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3 | PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura wody/pobranej probki wody\nZakres (0,0 – 50,0) °C PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.2 i 6.3 | PN-ISO 5667-6:2016-12 z wyl. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of water/of the water sample taken Range PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3 | PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 用于化学与物理检验的采样 水/所采水样的温度 范围 PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2 i 6.3 | PN-ISO 5667-6:2016-12 z wył. p.7.5, 7.6, 8.2 i 9.4 /+A11:2020-10 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","test_object_zh":"水","methodology_zh":"用于化学与物理检验的采样 水/所采水样的温度"},{"_id":"6a5e783f4cc76d93cba39e55","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach, woda z kąpielisk), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water, bathing water), water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach, woda z kąpielisk), woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6 Woda (w tym woda na plywalniach, woda z kapielisk), woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.4.2, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water, bathing water), water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2, 4.4.5, 4.4.6"},{"_id":"6a5e783f4cc76d93cba39e56","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru całkowitego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,02 – 5,0) mg/l"},{"name":"Stężenie chloru wolnego"},{"name":"Zakres","range":"(0,02 – 5,0) mg/l"},{"name":"Chlor związany (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,02 – 5,0) mg/l"},{"name":"Free chlorine concentration"},{"name":"Range","range":"(0,02 – 5,0) mg/l"},{"name":"Combined chlorine (calculated)"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego\nZakres:\nZakres (0,02 – 5,0) mg/l\nStężenie chloru wolnego\nZakres (0,02 – 5,0) mg/l\nChlor związany (z obliczeń)\nMetoda kolorymetryczna","reference":"GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167","norm_bases":["GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru całkowitego\nZakres:\nZakres (0,02 – 5,0) mg/l\nStężenie chloru wolnego\nZakres (0,02 – 5,0) mg/l\nChlor związany (z obliczeń)\nMetoda kolorymetryczna GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru calkowitego\nZakres:\nZakres (0,02 – 5,0) mg/l\nStezenie chloru wolnego\nZakres (0,02 – 5,0) mg/l\nChlor zwiazany (z obliczen)\nMetoda kolorymetryczna GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Total chlorine concentration Colorimetric method Range Free chlorine concentration Range Combined chlorine (calculated) GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167","parameters_zh":[{"name":"范围","range":"(0,02 – 5,0) mg/l"},{"name":"游离氯浓度"},{"name":"范围","range":"(0,02 – 5,0) mg/l"},{"name":"化合氯（由计算得出）"}],"search_zh":"水（含游泳池水）、生活饮用水 总氯浓度 比色法 范围 游离氯浓度 范围 化合氯（由计算得出） GdW/SL/PB-66 wyd.06 z dnia 01.09.2023 w oparciu o test Hach-Lange metoda 8021 i 8167","technique_zh":"比色法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"总氯浓度"},{"_id":"6a5e783f4cc76d93cba39e57","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe","test_object_en":"Wastewater, rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura ścieków/pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"parameters_en":[{"name":"Temperature of wastewater/collected wastewater sample"},{"name":"Range","range":"(0,0 – 50,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (0,0 – 50,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","norm_bases":["PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (0,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025 Scieki, wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow/pobranej probki sciekow\nZakres (0,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing Manual method Temperature of wastewater/collected wastewater sample Range PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水、雨水、融雪水 化学与物理检测用样品采集 手工法 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","test_object_zh":"污水、雨水、融雪水","technique_zh":"手工法"},{"_id":"6a5e783f4cc76d93cba39e58","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura ścieków"},{"name":"Zakres","range":"(5,0 – 30,0) °C"}],"parameters_en":[{"name":"Wastewater temperature"},{"name":"Range","range":"(5,0 – 30,0) °C"}],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"technique_en":"Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków\nZakres (5,0 – 30,0) °C\nMetoda automatyczna","reference":"PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","norm_bases":["PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków\nZakres (5,0 – 30,0) °C\nMetoda automatyczna PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow\nZakres (5,0 – 30,0) °C\nMetoda automatyczna PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method Wastewater temperature Range PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水温度"},{"name":"范围","range":"(5,0 – 30,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 自动法 废水温度 范围 PN-ISO 5667-10:2021-11 GdW/SL/PB-12 wyd. 07 z dnia 10.07.2025","test_object_zh":"污水","technique_zh":"自动法"},{"_id":"6a5e783f4cc76d93cba39e59","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e5a","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.1.3, 6.1.4.3, 6.1.4.4, 6.1.4.5, 6.2, 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10","test_object_zh":"污泥"},{"_id":"6a5e783f4cc76d93cba39e5b","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e5c","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5e783f4cc76d93cba39e5d","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,2 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,2 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,2 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,2 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,2 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e5e","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba progowa smaku (TFN)","methodology_en":"Taste threshold number (TFN)","parameters":[{"name":"Zakres","range":"1 – 2"}],"parameters_en":[{"name":"Range","range":"1 – 2"}],"technique":"Metoda uproszczona parzysta, wybór niewymuszony","techniques":["Metoda uproszczona parzysta, wybór niewymuszony"],"technique_en":"Simplified paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku (TFN)\nZakres 1 – 2\nMetoda uproszczona parzysta, wybór niewymuszony","reference":"GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-44 wyd.09 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1 – 2\nMetoda uproszczona parzysta, wybór niewymuszony GdW/SL/PB-44 wyd.09 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1 – 2\nMetoda uproszczona parzysta, wybor niewymuszony GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Taste threshold number (TFN) Simplified paired method, non-forced choice Range GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"水、生活饮用水 味阈值（TFN） 简化法、成对法、非强制选择 范围 GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","test_object_zh":"水、生活饮用水","methodology_zh":"味阈值（TFN）","technique_zh":"简化法、成对法、非强制选择"},{"_id":"6a5e783f4cc76d93cba39e5f","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba progowa zapachu (TON)","methodology_en":"Odour threshold number (TON)","parameters":[{"name":"Zakres","range":"1 – 2"}],"parameters_en":[{"name":"Range","range":"1 – 2"}],"technique":"Metoda uproszczona parzysta, wybór niewymuszony","techniques":["Metoda uproszczona parzysta, wybór niewymuszony"],"technique_en":"Simplified paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona parzysta, wybór niewymuszony","reference":"GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-44 wyd.09 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona parzysta, wybór niewymuszony GdW/SL/PB-44 wyd.09 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona parzysta, wybor niewymuszony GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Odour threshold number (TON) Simplified paired method, non-forced choice Range GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"水、生活饮用水 嗅阈值（TON） 简化法、成对法、非强制选择 范围 GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","test_object_zh":"水、生活饮用水","methodology_zh":"嗅阈值（TON）","technique_zh":"简化法、成对法、非强制选择"},{"_id":"6a5e783f4cc76d93cba39e60","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba progowa zapachu (TON)","methodology_en":"Odour threshold number (TON)","parameters":[{"name":"Zakres","range":"1 – 20"}],"parameters_en":[{"name":"Range","range":"1 – 20"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"technique_en":"Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu (TON)\nZakres 1 – 20\nMetoda pełna, parzysta, wybór niewymuszony","reference":"GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-44 wyd.09 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1 – 20\nMetoda pełna, parzysta, wybór niewymuszony GdW/SL/PB-44 wyd.09 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1 – 20\nMetoda pelna, parzysta, wybor niewymuszony GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Odour threshold number (TON) Full paired method, non-forced choice Range GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"1 – 20"}],"search_zh":"水、生活饮用水 嗅阈值（TON） 完全法、成对法、非强制选择 范围 GdW/SL/PB-44 wyd.09 z dnia 01.09.2023","test_object_zh":"水、生活饮用水","methodology_zh":"嗅阈值（TON）","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a5e783f4cc76d93cba39e61","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(1 – 2500) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (1 – 2500) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Sucha pozostałość\nZakres (1 – 2500) mg/l\nMetoda wagowa PN-78/C-04541 Woda, woda do spozycia przez ludzi Sucha pozostalosc\nZakres (1 – 2500) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Dry residue Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(1 – 2500) mg/l"}],"search_zh":"水、生活饮用水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、生活饮用水","methodology_zh":"干残渣"},{"_id":"6a5e783f4cc76d93cba39e62","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość ogólna","methodology_en":"Total hardness","parameters":[{"name":"Zakres","range":"(5 – 800) mg/l CaCO3"},{"name":"Zakres","range":"(0,1 – 16) mval/l"},{"name":"Zakres","range":"(0,05 – 8) mmol/l"}],"parameters_en":[{"name":"Range","range":"(5 – 800) mg/l CaCO3"},{"name":"Range","range":"(0,1 – 16) mval/l"},{"name":"Range","range":"(0,05 – 8) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna\nZakres:\nZakres (5 – 800) mg/l CaCO3\nZakres (0,1 – 16) mval/l\nZakres (0,05 – 8) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (5 – 800) mg/l CaCO3\nZakres (0,1 – 16) mval/l\nZakres (0,05 – 8) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (5 – 800) mg/l CaCO3\nZakres (0,1 – 16) mval/l\nZakres (0,05 – 8) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total hardness Titrimetric method Range Range Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5 – 800) mg/l CaCO3"},{"name":"范围","range":"(0,1 – 16) mval/l"},{"name":"范围","range":"(0,05 – 8) mmol/l"}],"search_zh":"水、生活饮用水 总硬度 滴定法 范围 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总硬度"},{"_id":"6a5e783f4cc76d93cba39e63","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość węglanowa, niewęglanowa (z obliczeń)","methodology_en":"Carbonate, non-carbonate hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość węglanowa, niewęglanowa (z obliczeń)","reference":"GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025","norm_bases":["GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość węglanowa, niewęglanowa (z obliczeń) GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025 Woda, woda do spozycia przez ludzi Twardosc weglanowa, nieweglanowa (z obliczen) GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Carbonate, non-carbonate hardness (calculated) GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025","search_zh":"水、生活饮用水 GdW/SL/PB-78 wyd. 01 z dnia 10.06.2025","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e64","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 – 320) mg/l"},{"name":"Twardość wapniowa"},{"name":"Zakres","range":"(5 – 800) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(2 – 320) mg/l"},{"name":"Calcium hardness"},{"name":"Range","range":"(5 – 800) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres:\nZakres (2 – 320) mg/l\nTwardość wapniowa\nZakres (5 – 800) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres:\nZakres (2 – 320) mg/l\nTwardość wapniowa\nZakres (5 – 800) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres:\nZakres (2 – 320) mg/l\nTwardosc wapniowa\nZakres (5 – 800) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range Calcium hardness Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 – 320) mg/l"},{"name":"钙硬度"},{"name":"范围","range":"(5 – 800) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 钙硬度 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5e783f4cc76d93cba39e65","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,05 – 51,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 51,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 51,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 51,5) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 51,5) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 51,5) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e66","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Zasadowość ogólna i mineralna","methodology_en":"Total and mineral alkalinity","parameters":[{"name":"Zakres","range":"(0,4 – 20) mmol/l"},{"name":"Zakres","range":"(0,4 – 20) mval/l"},{"name":"Zakres","range":"(20 – 1000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,4 – 20) mmol/l"},{"name":"Range","range":"(0,4 – 20) mval/l"},{"name":"Range","range":"(20 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna i mineralna\nZakres:\nZakres (0,4 – 20) mmol/l\nZakres (0,4 – 20) mval/l\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Zasadowość ogólna i mineralna\nZakres:\nZakres (0,4 – 20) mmol/l\nZakres (0,4 – 20) mval/l\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, woda do spozycia przez ludzi Zasadowosc ogolna i mineralna\nZakres:\nZakres (0,4 – 20) mmol/l\nZakres (0,4 – 20) mval/l\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total and mineral alkalinity Titrimetric method Range Range Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,4 – 20) mmol/l"},{"name":"范围","range":"(0,4 – 20) mval/l"},{"name":"范围","range":"(20 – 1000) mg/l CaCO3"}],"search_zh":"水、生活饮用水 滴定法 范围 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e67","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wodorowęglanów (z obliczeń)","methodology_en":"Bicarbonate concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wodorowęglanów (z obliczeń)","reference":"GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025","norm_bases":["GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wodorowęglanów (z obliczeń) GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025 Woda, woda do spozycia przez ludzi Stezenie wodoroweglanow (z obliczen) GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Bicarbonate concentration (calculated) GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025","search_zh":"水、生活饮用水 碳酸氢盐浓度（由计算得出） GdW/SL/PB-79 wyd. 01 z dnia 10.06.2025","test_object_zh":"水、生活饮用水","methodology_zh":"碳酸氢盐浓度（由计算得出）"},{"_id":"6a5e783f4cc76d93cba39e68","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2 – 200) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2 – 200) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2 – 200) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (2 – 200) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (2 – 200) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 200) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e69","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Zawartość substancji organicznych pochłaniających promieniowanie UV (absorbancja)","methodology_en":"Content of organic substances absorbing UV radiation (absorbance)","parameters":[{"name":"Zakres","range":"(0,050 – 1,80) A"},{"name":"Zakres","range":"(0,010 – 0,360) cm-1"}],"parameters_en":[{"name":"Range","range":"(0,050 – 1,80) A"},{"name":"Range","range":"(0,010 – 0,360) cm-1"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość substancji organicznych pochłaniających promieniowanie UV (absorbancja)\nZakres:\nZakres (0,050 – 1,80) A\nZakres (0,010 – 0,360) cm-1\nMetoda spektrofotometryczna","reference":"GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025","norm_bases":["GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Zawartość substancji organicznych pochłaniających promieniowanie UV (absorbancja)\nZakres:\nZakres (0,050 – 1,80) A\nZakres (0,010 – 0,360) cm-1\nMetoda spektrofotometryczna GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025 Woda, woda do spozycia przez ludzi Zawartosc substancji organicznych pochlaniajacych promieniowanie UV (absorbancja)\nZakres:\nZakres (0,050 – 1,80) A\nZakres (0,010 – 0,360) cm-1\nMetoda spektrofotometryczna GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Content of organic substances absorbing UV radiation (absorbance) Spectrophotometric method Range Range GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025","parameters_zh":[{"name":"范围","range":"(0,050 – 1,80) A"},{"name":"范围","range":"(0,010 – 0,360) cm-1"}],"search_zh":"水、生活饮用水 分光光度法 范围 范围 GdW/SL/PB-76 wyd. 01 z dnia 10.07.2025","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e6a","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a5e783f4cc76d93cba39e6b","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,2 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,2 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,2 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Mętność\nZakres (0,2 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc\nZakres (0,2 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2 – 100) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a5e783f4cc76d93cba39e6c","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a5e783f4cc76d93cba39e6d","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(0,6 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,6 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wył. p. 7.2 | ISO 17289 :2014","norm_bases":["PN-EN 1899-2:2002 z wył. p. 7.2","ISO 17289 :2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wył. p. 7.2 | ISO 17289 :2014 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyl. p. 7.2 | ISO 17289 :2014","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN 1899-2:2002 z wył. p. 7.2 | ISO 17289 :2014","parameters_zh":[{"name":"范围","range":"(0,6 – 6,0) mg/l O2"}],"search_zh":"水、生活饮用水、污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN 1899-2:2002 z wył. p. 7.2 | ISO 17289 :2014","technique_zh":"光学法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5e783f4cc76d93cba39e6e","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5e783f4cc76d93cba39e6f","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (5 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (5 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5e783f4cc76d93cba39e70","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5e783f4cc76d93cba39e71","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie o-fosforanów","methodology_en":"o-phosphate concentration","parameters":[{"name":"Zakres","range":"(0,04 – 40) mg/l PO4"}],"parameters_en":[{"name":"Range","range":"(0,04 – 40) mg/l PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie o-fosforanów\nZakres (0,04 – 40) mg/l PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie o-fosforanów\nZakres (0,04 – 40) mg/l PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010 Woda, woda do spozycia przez ludzi, scieki Stezenie o-fosforanow\nZakres (0,04 – 40) mg/l PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater o-phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,04 – 40) mg/l PO4"}],"search_zh":"水、生活饮用水、污水 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 pkt. 4+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5e783f4cc76d93cba39e72","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 10000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (5 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (5 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 10000) μS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5e783f4cc76d93cba39e73","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów (detergentów) anionowych","methodology_en":"Concentration of anionic surfactants (detergents)","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów (detergentów) anionowych\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów (detergentów) anionowych\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, scieki Stezenie surfaktantow (detergentow) anionowych\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of anionic surfactants (detergents) Spectrophotometric method Range PN-EN 903:2002","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5e783f4cc76d93cba39e74","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie substancji rozpuszczonych ogólnych","methodology_en":"Total dissolved solids concentration","parameters":[{"name":"Zakres","range":"(1 – 2500) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji rozpuszczonych ogólnych\nZakres (1 – 2500) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie substancji rozpuszczonych ogólnych\nZakres (1 – 2500) mg/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Stezenie substancji rozpuszczonych ogolnych\nZakres (1 – 2500) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total dissolved solids concentration Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(1 – 2500) mg/l"}],"search_zh":"水、废水 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5e783f4cc76d93cba39e75","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,002 – 0,500) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 – 0,500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,002 – 0,500) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,002 – 0,500) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,002 – 0,500) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","parameters_zh":[{"name":"范围","range":"(0,002 – 0,500) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a5e783f4cc76d93cba39e76","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","methodology_en":"Chemical oxygen demand - COD-Cr","parameters":[{"name":"Zakres","range":"(5 – 150) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5 – 150) mg/l O2"}],"search_zh":"水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5e783f4cc76d93cba39e77","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie substancji organicznych ekstrahujących się eterem naftowym","methodology_en":"Concentration of organic substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(0,8 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,8 – 10,0) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (0,8 – 10,0) mg/l\nMetoda wagowa","reference":"PN-86/C-04573.01","norm_bases":["PN-86/C-04573.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (0,8 – 10,0) mg/l\nMetoda wagowa PN-86/C-04573.01 Woda Stezenie substancji organicznych ekstrahujacych sie eterem naftowym\nZakres (0,8 – 10,0) mg/l\nMetoda wagowa PN-86/C-04573.01","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of organic substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573.01","parameters_zh":[{"name":"范围","range":"(0,8 – 10,0) mg/l"}],"search_zh":"水 石油醚可萃取有机物质浓度 重量法 范围 PN-86/C-04573.01","technique_zh":"重量法","test_object_zh":"水","methodology_zh":"石油醚可萃取有机物质浓度"},{"_id":"6a5e783f4cc76d93cba39e78","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 100) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zawiesiny ogólne\nZakres (2,0 – 100) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne\nZakres (2,0 – 100) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/l"}],"search_zh":"水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5e783f4cc76d93cba39e79","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 50) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1 – 50) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (1 – 50) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (1 – 50) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 50) mg/l"}],"search_zh":"水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5e783f4cc76d93cba39e7a","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e7b","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zasadowość ogólna i mineralna","methodology_en":"Total and mineral alkalinity","parameters":[{"name":"Zakres","range":"(0,4 – 20) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,4 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna i mineralna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zasadowość ogólna i mineralna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Scieki Zasadowosc ogolna i mineralna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total and mineral alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,4 – 20) mmol/l"}],"search_zh":"污水 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e7c","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie substancji organicznych ekstrahujących się eterem naftowym","methodology_en":"Concentration of organic substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(0,8 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,8 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (0,8 – 500) mg/l\nMetoda wagowa","reference":"PN-86/C-04573.01","norm_bases":["PN-86/C-04573.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (0,8 – 500) mg/l\nMetoda wagowa PN-86/C-04573.01 Scieki Stezenie substancji organicznych ekstrahujacych sie eterem naftowym\nZakres (0,8 – 500) mg/l\nMetoda wagowa PN-86/C-04573.01","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of organic substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573.01","parameters_zh":[{"name":"范围","range":"(0,8 – 500) mg/l"}],"search_zh":"污水 石油醚可萃取有机物质浓度 重量法 范围 PN-86/C-04573.01","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取有机物质浓度"},{"_id":"6a5e783f4cc76d93cba39e7d","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,5 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,5 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (0,5 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 250) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e7e","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 500) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e7f","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e80","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarkowodoru i siarczków","methodology_en":"Hydrogen sulfide and sulfide concentration","parameters":[{"name":"Zakres","range":"(0,04 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 20) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarkowodoru i siarczków\nZakres (0,04 – 20) mg/l\nMetoda miareczkowa","reference":"PN-82/C-04566.03","norm_bases":["PN-82/C-04566.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarkowodoru i siarczków\nZakres (0,04 – 20) mg/l\nMetoda miareczkowa PN-82/C-04566.03 Scieki Stezenie siarkowodoru i siarczkow\nZakres (0,04 – 20) mg/l\nMetoda miareczkowa PN-82/C-04566.03","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Hydrogen sulfide and sulfide concentration Titrimetric method Range PN-82/C-04566.03","parameters_zh":[{"name":"范围","range":"(0,04 – 20) mg/l"}],"search_zh":"污水 硫化氢与硫化物浓度 滴定法 范围 PN-82/C-04566.03","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"硫化氢与硫化物浓度"},{"_id":"6a5e783f4cc76d93cba39e81","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","methodology_en":"Chemical oxygen demand - COD-Cr","parameters":[{"name":"Zakres","range":"(5 – 20000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5 – 20000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 20000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 20000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 20000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5 – 20000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5e783f4cc76d93cba39e82","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki (w tym wody opadowe i roztopowe) pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"废水（含雨水与融雪水） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5e783f4cc76d93cba39e83","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 10000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Przewodność elektryczna właściwa\nZakres (5 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki (w tym wody opadowe i roztopowe) Przewodnosc elektryczna wlasciwa\nZakres (5 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 10000) μS/cm"}],"search_zh":"废水（含雨水与融雪水） 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5e783f4cc76d93cba39e84","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Zawiesiny ogólne, Zakres(2,0 – 2000) mg/l","methodology_en":"Total suspended solids, Range(2,0 – 2000) mg/l","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne, Zakres(2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Zawiesiny ogólne, Zakres(2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki (w tym wody opadowe i roztopowe) Zawiesiny ogolne, Zakres(2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Total suspended solids, Range(2,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"废水（含雨水与融雪水） 重量法 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5e783f4cc76d93cba39e85","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","methodology_en":"Chemical oxygen demand - COD-Cr","parameters":[{"name":"Zakres","range":"(5 – 20000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5 – 20000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 20000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 20000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki (w tym wody opadowe i roztopowe) Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 20000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5 – 20000) mg/l O2"}],"search_zh":"废水（含雨水与融雪水） 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD-Cr）","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5e783f4cc76d93cba39e86","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(30 – 2000) mg/kg os. uwod."},{"name":"Zakres","range":"(0,1 – 3,0) % N w s. m. osadu"}],"parameters_en":[{"name":"Range","range":"(30 – 2000) mg/kg os. uwod."},{"name":"Range","range":"(0,1 – 3,0) % N w s. m. osadu"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres:\nZakres (30 – 2000) mg/kg os. uwod.\nZakres (0,1 – 3,0) % N w s. m. osadu\nMetoda miareczkowa","reference":"GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-36 wyd.09 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres:\nZakres (30 – 2000) mg/kg os. uwod.\nZakres (0,1 – 3,0) % N w s. m. osadu\nMetoda miareczkowa GdW/SL/PB-36 wyd.09 z dnia 01.09.2023 Osady sciekowe Zawartosc azotu amonowego\nZakres:\nZakres (30 – 2000) mg/kg os. uwod.\nZakres (0,1 – 3,0) % N w s. m. osadu\nMetoda miareczkowa GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range Range GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"(30 – 2000) mg/kg os. uwod."},{"name":"范围","range":"(0,1 – 3,0) % N w s. m. osadu"}],"search_zh":"污泥 氨氮含量 滴定法 范围 范围 GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a5e783f4cc76d93cba39e87","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu ogólnego Kjeldahla","methodology_en":"Total Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(30 – 5000) mg/kg os. uwod."},{"name":"Zakres","range":"(0,5 – 10,0) % N w s. m. osadu"}],"parameters_en":[{"name":"Range","range":"(30 – 5000) mg/kg os. uwod."},{"name":"Range","range":"(0,5 – 10,0) % N w s. m. osadu"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres:\nZakres (30 – 5000) mg/kg os. uwod.\nZakres (0,5 – 10,0) % N w s. m. osadu\nMetoda miareczkowa","reference":"GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-36 wyd.09 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu ogólnego Kjeldahla\nZakres:\nZakres (30 – 5000) mg/kg os. uwod.\nZakres (0,5 – 10,0) % N w s. m. osadu\nMetoda miareczkowa GdW/SL/PB-36 wyd.09 z dnia 01.09.2023 Osady sciekowe Zawartosc azotu ogolnego Kjeldahla\nZakres:\nZakres (30 – 5000) mg/kg os. uwod.\nZakres (0,5 – 10,0) % N w s. m. osadu\nMetoda miareczkowa GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total Kjeldahl nitrogen content Titrimetric method Range Range GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"(30 – 5000) mg/kg os. uwod."},{"name":"范围","range":"(0,5 – 10,0) % N w s. m. osadu"}],"search_zh":"污泥 凯氏总氮含量 滴定法 范围 范围 GdW/SL/PB-36 wyd.09 z dnia 01.09.2023","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏总氮含量"},{"_id":"6a5e783f4cc76d93cba39e88","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,01 – 10,0) % P w os. suchym"}],"parameters_en":[{"name":"Range","range":"(0,01 – 10,0) % P w os. suchym"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,01 – 10,0) % P w os. suchym\nMetoda spektrofotometryczna","reference":"GdW/SL/PB-35 wyd.08 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-35 wyd.08 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,01 – 10,0) % P w os. suchym\nMetoda spektrofotometryczna GdW/SL/PB-35 wyd.08 z dnia 01.09.2023 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,01 – 10,0) % P w os. suchym\nMetoda spektrofotometryczna GdW/SL/PB-35 wyd.08 z dnia 01.09.2023","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range GdW/SL/PB-35 wyd.08 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"(0,01 – 10,0) % P w os. suchym"}],"search_zh":"污泥 总磷含量 分光光度法 范围 GdW/SL/PB-35 wyd.08 z dnia 01.09.2023","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a5e783f4cc76d93cba39e89","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH Potentiometric method Range PN-EN 12176:2004","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a5e783f4cc76d93cba39e8a","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0005 – 0,050) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0005 – 0,050) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)"],"technique_en":"Mercury cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","reference":"PN-EN ISO 12846:2012 z wył. p.6","norm_bases":["PN-EN ISO 12846:2012 z wył. p.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie rtęci\nZakres (0,0005 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS) PN-EN ISO 12846:2012 z wył. p.6 Woda, woda do spozycia przez ludzi Stezenie rteci\nZakres (0,0005 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rteci (CVAAS) PN-EN ISO 12846:2012 z wyl. p.6","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Mercury concentration Mercury cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 z wył. p.6","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,050) mg/l"}],"search_zh":"水、生活饮用水 汞浓度 汞冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 z wył. p.6","test_object_zh":"水、生活饮用水","technique_zh":"汞冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a5e783f4cc76d93cba39e8b","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie selenu","methodology_en":"Selenium concentration","parameters":[{"name":"Zakres","range":"(0,001 – 0,100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,100) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie selenu\nZakres (0,001 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PN-ISO 9965:2001","norm_bases":["PN-ISO 9965:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie selenu\nZakres (0,001 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PN-ISO 9965:2001 Woda, woda do spozycia przez ludzi Stezenie selenu\nZakres (0,001 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PN-ISO 9965:2001","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Selenium concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PN-ISO 9965:2001","parameters_zh":[{"name":"范围","range":"(0,001 – 0,100) mg/l"}],"search_zh":"水、生活饮用水 硒浓度 氢化物发生原子吸收光谱法（HGAAS） 范围 PN-ISO 9965:2001","test_object_zh":"水、生活饮用水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"硒浓度"},{"_id":"6a5e783f4cc76d93cba39e8c","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie antymonu","methodology_en":"Antimony concentration","parameters":[{"name":"Zakres","range":"(0,001 – 0,100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,100) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie antymonu\nZakres (0,001 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025","norm_bases":["GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie antymonu\nZakres (0,001 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025 Woda, woda do spozycia przez ludzi Stezenie antymonu\nZakres (0,001 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Antimony concentration Hydride generation atomic absorption spectrometry (HGAAS) Range GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025","parameters_zh":[{"name":"范围","range":"(0,001 – 0,100) mg/l"}],"search_zh":"水、生活饮用水 锑浓度 氢化物发生原子吸收光谱法（HGAAS） 范围 GdW/SL/PB-17 wyd. 07 z dnia 10.06.2025","test_object_zh":"水、生活饮用水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"锑浓度"},{"_id":"6a5e783f4cc76d93cba39e8d","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie ogólnego (OWO) i rozpuszczonego (RWO) węgla organicznego","methodology_en":"Concentration of total (TOC) and dissolved (DOC) organic carbon","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego (OWO) i rozpuszczonego (RWO) węgla organicznego\nZakres (0,5 – 20) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"P N - EN 1484:1999","norm_bases":["P N - EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ogólnego (OWO) i rozpuszczonego (RWO) węgla organicznego\nZakres (0,5 – 20) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) P N - EN 1484:1999 Woda, woda do spozycia przez ludzi Stezenie ogolnego (OWO) i rozpuszczonego (RWO) wegla organicznego\nZakres (0,5 – 20) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) P N - EN 1484:1999","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of total (TOC) and dissolved (DOC) organic carbon Spectrometry method in the infrared range (IR) Range P N - EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l"}],"search_zh":"水、生活饮用水 红外光谱法（IR） 范围 P N - EN 1484:1999","test_object_zh":"水、生活饮用水","technique_zh":"红外光谱法（IR）"},{"_id":"6a5e783f4cc76d93cba39e8e","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(0,05 – 500) mg/l"},{"name":"Stężenie potasu"},{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 500) mg/l"},{"name":"Potassium concentration"},{"name":"Range","range":"(0,05 – 100) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"technique_en":"Flame atomic emission spectrometry (FAES)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres:\nZakres (0,05 – 500) mg/l\nStężenie potasu\nZakres (0,05 – 100) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie sodu\nZakres:\nZakres (0,05 – 500) mg/l\nStężenie potasu\nZakres (0,05 – 100) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994 Woda, woda do spozycia przez ludzi Stezenie sodu\nZakres:\nZakres (0,05 – 500) mg/l\nStezenie potasu\nZakres (0,05 – 100) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sodium concentration Flame atomic emission spectrometry (FAES) Range Potassium concentration Range PN-ISO 9964-3:1994","parameters_zh":[{"name":"范围","range":"(0,05 – 500) mg/l"},{"name":"钾浓度"},{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"水、生活饮用水 钠浓度 火焰原子发射光谱法（FAES） 范围 钾浓度 范围 PN-ISO 9964-3:1994","test_object_zh":"水、生活饮用水","methodology_zh":"钠浓度","technique_zh":"火焰原子发射光谱法（FAES）"},{"_id":"6a5e783f4cc76d93cba39e8f","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"miedź","range":"(0,004 – 0,500) mg/l"},{"name":"kadm","range":"(0,0003 – 0,500) mg/l"},{"name":"ołów","range":"(0,002 – 0,500) mg/l"},{"name":"chrom","range":"(0,0004 – 0,500) mg/l"},{"name":"nikiel","range":"(0,003 – 0,500) mg/l"},{"name":"srebro","range":"(0,003 – 0,500) mg/l"},{"name":"arsen","range":"(0,003 – 0,500) mg/l"},{"name":"mangan","range":"(0,005 – 2,00) mg/l"},{"name":"wanad","range":"(0,004 – 0,500) mg/l"},{"name":"glin","range":"(0,02 – 2,00) mg/l"}],"parameters_en":[{"name":"copper","range":"(0,004 – 0,500) mg/l"},{"name":"cadmium","range":"(0,0003 – 0,500) mg/l"},{"name":"lead","range":"(0,002 – 0,500) mg/l"},{"name":"chromium","range":"(0,0004 – 0,500) mg/l"},{"name":"nickel","range":"(0,003 – 0,500) mg/l"},{"name":"silver","range":"(0,003 – 0,500) mg/l"},{"name":"arsenic","range":"(0,003 – 0,500) mg/l"},{"name":"manganese","range":"(0,005 – 2,00) mg/l"},{"name":"vanadium","range":"(0,004 – 0,500) mg/l"},{"name":"aluminium","range":"(0,02 – 2,00) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nmiedź (0,004 – 0,500) mg/l\nkadm (0,0003 – 0,500) mg/l\nołów (0,002 – 0,500) mg/l\nchrom (0,0004 – 0,500) mg/l\nnikiel (0,003 – 0,500) mg/l\nsrebro (0,003 – 0,500) mg/l\narsen (0,003 – 0,500) mg/l\nmangan (0,005 – 2,00) mg/l\nwanad (0,004 – 0,500) mg/l\nglin (0,02 – 2,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie metali\nZakres:\nmiedź (0,004 – 0,500) mg/l\nkadm (0,0003 – 0,500) mg/l\nołów (0,002 – 0,500) mg/l\nchrom (0,0004 – 0,500) mg/l\nnikiel (0,003 – 0,500) mg/l\nsrebro (0,003 – 0,500) mg/l\narsen (0,003 – 0,500) mg/l\nmangan (0,005 – 2,00) mg/l\nwanad (0,004 – 0,500) mg/l\nglin (0,02 – 2,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, woda do spozycia przez ludzi Stezenie metali\nZakres:\nmiedz (0,004 – 0,500) mg/l\nkadm (0,0003 – 0,500) mg/l\nolow (0,002 – 0,500) mg/l\nchrom (0,0004 – 0,500) mg/l\nnikiel (0,003 – 0,500) mg/l\nsrebro (0,003 – 0,500) mg/l\narsen (0,003 – 0,500) mg/l\nmangan (0,005 – 2,00) mg/l\nwanad (0,004 – 0,500) mg/l\nglin (0,02 – 2,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) copper cadmium lead chromium nickel silver arsenic manganese vanadium aluminium PN-EN ISO 15586:2005","methodology_zh":"金属浓度","parameters_zh":[{"name":"铜","range":"(0,004 – 0,500) mg/l"},{"name":"镉","range":"(0,0003 – 0,500) mg/l"},{"name":"铅","range":"(0,002 – 0,500) mg/l"},{"name":"铬","range":"(0,0004 – 0,500) mg/l"},{"name":"镍","range":"(0,003 – 0,500) mg/l"},{"name":"银","range":"(0,003 – 0,500) mg/l"},{"name":"砷","range":"(0,003 – 0,500) mg/l"},{"name":"锰","range":"(0,005 – 2,00) mg/l"},{"name":"钒","range":"(0,004 – 0,500) mg/l"},{"name":"铝","range":"(0,02 – 2,00) mg/l"}],"search_zh":"水、生活饮用水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 铜 镉 铅 铬 镍 银 砷 锰 钒 铝 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e90","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"cynk","range":"(0,1– 10) mg/l"},{"name":"żelazo","range":"(0,2 – 10) mg/l"}],"parameters_en":[{"name":"zinc","range":"(0,1– 10) mg/l"},{"name":"iron","range":"(0,2 – 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\ncynk (0,1– 10) mg/l\nżelazo (0,2 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie metali\nZakres:\ncynk (0,1– 10) mg/l\nżelazo (0,2 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki Stezenie metali\nZakres:\ncynk (0,1– 10) mg/l\nzelazo (0,2 – 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) zinc iron PN-ISO 8288:2002 metoda A","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,1– 10) mg/l"},{"name":"铁","range":"(0,2 – 10) mg/l"}],"search_zh":"污水 金属浓度 火焰原子吸收光谱法（FAAS） 锌 铁 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e91","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"miedź","range":"(0,004 – 0,500) mg/l"},{"name":"kadm","range":"(0,0003 – 0,500) mg/l"},{"name":"ołów","range":"(0,002 – 0,500) mg/l"},{"name":"chrom","range":"(0,0004 – 0,500) mg/l"},{"name":"nikiel","range":"(0,003 – 0,500) mg/l"},{"name":"srebro","range":"(0,003 – 0,500) mg/l"},{"name":"arsen","range":"(0,003 – 0,500) mg/l"},{"name":"wanad","range":"(0,004 – 0,500) mg/l"}],"parameters_en":[{"name":"copper","range":"(0,004 – 0,500) mg/l"},{"name":"cadmium","range":"(0,0003 – 0,500) mg/l"},{"name":"lead","range":"(0,002 – 0,500) mg/l"},{"name":"chromium","range":"(0,0004 – 0,500) mg/l"},{"name":"nickel","range":"(0,003 – 0,500) mg/l"},{"name":"silver","range":"(0,003 – 0,500) mg/l"},{"name":"arsenic","range":"(0,003 – 0,500) mg/l"},{"name":"vanadium","range":"(0,004 – 0,500) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nmiedź (0,004 – 0,500) mg/l\nkadm (0,0003 – 0,500) mg/l\nołów (0,002 – 0,500) mg/l\nchrom (0,0004 – 0,500) mg/l\nnikiel (0,003 – 0,500) mg/l\nsrebro (0,003 – 0,500) mg/l\narsen (0,003 – 0,500) mg/l\nwanad (0,004 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie metali\nZakres:\nmiedź (0,004 – 0,500) mg/l\nkadm (0,0003 – 0,500) mg/l\nołów (0,002 – 0,500) mg/l\nchrom (0,0004 – 0,500) mg/l\nnikiel (0,003 – 0,500) mg/l\nsrebro (0,003 – 0,500) mg/l\narsen (0,003 – 0,500) mg/l\nwanad (0,004 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie metali\nZakres:\nmiedz (0,004 – 0,500) mg/l\nkadm (0,0003 – 0,500) mg/l\nolow (0,002 – 0,500) mg/l\nchrom (0,0004 – 0,500) mg/l\nnikiel (0,003 – 0,500) mg/l\nsrebro (0,003 – 0,500) mg/l\narsen (0,003 – 0,500) mg/l\nwanad (0,004 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) copper cadmium lead chromium nickel silver arsenic vanadium PN-EN ISO 15586:2005","methodology_zh":"金属浓度","parameters_zh":[{"name":"铜","range":"(0,004 – 0,500) mg/l"},{"name":"镉","range":"(0,0003 – 0,500) mg/l"},{"name":"铅","range":"(0,002 – 0,500) mg/l"},{"name":"铬","range":"(0,0004 – 0,500) mg/l"},{"name":"镍","range":"(0,003 – 0,500) mg/l"},{"name":"银","range":"(0,003 – 0,500) mg/l"},{"name":"砷","range":"(0,003 – 0,500) mg/l"},{"name":"钒","range":"(0,004 – 0,500) mg/l"}],"search_zh":"污水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 铜 镉 铅 铬 镍 银 砷 钒 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39e92","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,001 – 0,050) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,050) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)"],"technique_en":"Mercury cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,001 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","reference":"PN-EN ISO 12846:2012 z wył. p.6","norm_bases":["PN-EN ISO 12846:2012 z wył. p.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci\nZakres (0,001 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS) PN-EN ISO 12846:2012 z wył. p.6 Scieki Stezenie rteci\nZakres (0,001 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rteci (CVAAS) PN-EN ISO 12846:2012 z wyl. p.6","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Mercury concentration Mercury cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 z wył. p.6","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 0,050) mg/l"}],"search_zh":"污水 汞浓度 汞冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 z wył. p.6","test_object_zh":"污水","technique_zh":"汞冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a5e783f4cc76d93cba39e93","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(3 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(3 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (3 – 1000) mg/l\nMetoda spektrofotometryczna","reference":"GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386","norm_bases":["GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Stężenie ogólnego węgla organicznego (OWO)\nZakres (3 – 1000) mg/l\nMetoda spektrofotometryczna GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386 Scieki (w tym wody opadowe i roztopowe) Stezenie ogolnego wegla organicznego (OWO)\nZakres (3 – 1000) mg/l\nMetoda spektrofotometryczna GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Total organic carbon concentration (TOC) Spectrophotometric method Range GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386","parameters_zh":[{"name":"范围","range":"(3 – 1000) mg/l"}],"search_zh":"废水（含雨水与融雪水） 总有机碳浓度（TOC） 分光光度法 范围 GdW/SL/PB-81 wyd. 01.10.07.2025 na podstawie testu kuwetowego HACH LANGE nr LCK385 i LCK 386","technique_zh":"分光光度法","methodology_zh":"总有机碳浓度（TOC）","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5e783f4cc76d93cba39e94","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"antymon","range":"(1,0 – 10000) μg/l"},{"name":"arsen","range":"(1,0 – 10000) μg/l"},{"name":"bar","range":"(1,0 – 10000) μg/l"},{"name":"beryl","range":"(1,0 – 10000) μg/l"},{"name":"bor","range":"(50 – 10000) μg/l"},{"name":"chrom","range":"(1,0 – 10000) μg/l"},{"name":"cyna","range":"(1,0 – 10000) μg/l"},{"name":"cynk","range":"(50 – 50000) μg/l"},{"name":"fosfor","range":"(0,05 – 100) mg/l"},{"name":"glin","range":"(50 – 10000) μg/l"},{"name":"kadm","range":"(1,0 – 10000) μg/l"},{"name":"kobalt","range":"(1,0 – 10000) μg/l"},{"name":"mangan","range":"(5,0 – 50000) μg/l"},{"name":"miedź","range":"(5,0 – 10000) μg/l"},{"name":"molibden","range":"(1,0 – 10000) μg/l"},{"name":"nikiel","range":"(5,0 – 10000) μg/l"},{"name":"ołów","range":"(1,0 – 10000) μg/l"},{"name":"rtęć","range":"(0,50 – 200) μg/l"},{"name":"selen","range":"(5,0 – 10000) μg/l"},{"name":"srebro","range":"(5,0 – 10000) μg/l"},{"name":"stront","range":"(1,0 – 10000) μg/l"},{"name":"tal","range":"(1,0 – 10000) μg/l"},{"name":"tytan","range":"( 1,0 – 10000) μg/l"},{"name":"uran","range":"(1,0 – 10000) μg/l"},{"name":"wanad","range":"(5,0 – 10000) μg/l"},{"name":"żelazo","range":"(50 – 50000) μg/l"}],"parameters_en":[{"name":"antimony","range":"(1,0 – 10000) μg/l"},{"name":"arsenic","range":"(1,0 – 10000) μg/l"},{"name":"barium","range":"(1,0 – 10000) μg/l"},{"name":"beryllium","range":"(1,0 – 10000) μg/l"},{"name":"boron","range":"(50 – 10000) μg/l"},{"name":"chromium","range":"(1,0 – 10000) μg/l"},{"name":"tin","range":"(1,0 – 10000) μg/l"},{"name":"zinc","range":"(50 – 50000) μg/l"},{"name":"phosphorus","range":"(0,05 – 100) mg/l"},{"name":"aluminium","range":"(50 – 10000) μg/l"},{"name":"cadmium","range":"(1,0 – 10000) μg/l"},{"name":"cobalt","range":"(1,0 – 10000) μg/l"},{"name":"manganese","range":"(5,0 – 50000) μg/l"},{"name":"copper","range":"(5,0 – 10000) μg/l"},{"name":"molybdenum","range":"(1,0 – 10000) μg/l"},{"name":"nickel","range":"(5,0 – 10000) μg/l"},{"name":"lead","range":"(1,0 – 10000) μg/l"},{"name":"mercury","range":"(0,50 – 200) μg/l"},{"name":"selenium","range":"(5,0 – 10000) μg/l"},{"name":"silver","range":"(5,0 – 10000) μg/l"},{"name":"strontium","range":"(1,0 – 10000) μg/l"},{"name":"thallium","range":"(1,0 – 10000) μg/l"},{"name":"titanium","range":"( 1,0 – 10000) μg/l"},{"name":"uranium","range":"(1,0 – 10000) μg/l"},{"name":"vanadium","range":"(5,0 – 10000) μg/l"},{"name":"iron","range":"(50 – 50000) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry method (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nantymon (1,0 – 10000) μg/l\narsen (1,0 – 10000) μg/l\nbar (1,0 – 10000) μg/l\nberyl (1,0 – 10000) μg/l\nbor (50 – 10000) μg/l\nchrom (1,0 – 10000) μg/l\ncyna (1,0 – 10000) μg/l\ncynk (50 – 50000) μg/l\nfosfor (0,05 – 100) mg/l\nglin (50 – 10000) μg/l\nkadm (1,0 – 10000) μg/l\nkobalt (1,0 – 10000) μg/l\nmangan (5,0 – 50000) μg/l\nmiedź (5,0 – 10000) μg/l\nmolibden (1,0 – 10000) μg/l\nnikiel (5,0 – 10000) μg/l\nołów (1,0 – 10000) μg/l\nrtęć (0,50 – 200) μg/l\nselen (5,0 – 10000) μg/l\nsrebro (5,0 – 10000) μg/l\nstront (1,0 – 10000) μg/l\ntal (1,0 – 10000) μg/l\ntytan ( 1,0 – 10000) μg/l\nuran (1,0 – 10000) μg/l\nwanad (5,0 – 10000) μg/l\nżelazo (50 – 50000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Stężenie pierwiastków\nZakres:\nantymon (1,0 – 10000) μg/l\narsen (1,0 – 10000) μg/l\nbar (1,0 – 10000) μg/l\nberyl (1,0 – 10000) μg/l\nbor (50 – 10000) μg/l\nchrom (1,0 – 10000) μg/l\ncyna (1,0 – 10000) μg/l\ncynk (50 – 50000) μg/l\nfosfor (0,05 – 100) mg/l\nglin (50 – 10000) μg/l\nkadm (1,0 – 10000) μg/l\nkobalt (1,0 – 10000) μg/l\nmangan (5,0 – 50000) μg/l\nmiedź (5,0 – 10000) μg/l\nmolibden (1,0 – 10000) μg/l\nnikiel (5,0 – 10000) μg/l\nołów (1,0 – 10000) μg/l\nrtęć (0,50 – 200) μg/l\nselen (5,0 – 10000) μg/l\nsrebro (5,0 – 10000) μg/l\nstront (1,0 – 10000) μg/l\ntal (1,0 – 10000) μg/l\ntytan ( 1,0 – 10000) μg/l\nuran (1,0 – 10000) μg/l\nwanad (5,0 – 10000) μg/l\nżelazo (50 – 50000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Scieki (w tym wody opadowe i roztopowe) Stezenie pierwiastkow\nZakres:\nantymon (1,0 – 10000) μg/l\narsen (1,0 – 10000) μg/l\nbar (1,0 – 10000) μg/l\nberyl (1,0 – 10000) μg/l\nbor (50 – 10000) μg/l\nchrom (1,0 – 10000) μg/l\ncyna (1,0 – 10000) μg/l\ncynk (50 – 50000) μg/l\nfosfor (0,05 – 100) mg/l\nglin (50 – 10000) μg/l\nkadm (1,0 – 10000) μg/l\nkobalt (1,0 – 10000) μg/l\nmangan (5,0 – 50000) μg/l\nmiedz (5,0 – 10000) μg/l\nmolibden (1,0 – 10000) μg/l\nnikiel (5,0 – 10000) μg/l\nolow (1,0 – 10000) μg/l\nrtec (0,50 – 200) μg/l\nselen (5,0 – 10000) μg/l\nsrebro (5,0 – 10000) μg/l\nstront (1,0 – 10000) μg/l\ntal (1,0 – 10000) μg/l\ntytan ( 1,0 – 10000) μg/l\nuran (1,0 – 10000) μg/l\nwanad (5,0 – 10000) μg/l\nzelazo (50 – 50000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Element concentration Inductively coupled plasma mass spectrometry method (ICP-MS) antimony arsenic barium beryllium boron chromium tin zinc phosphorus aluminium cadmium cobalt manganese copper molybdenum nickel lead mercury selenium silver strontium thallium titanium uranium vanadium iron PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"锑","range":"(1,0 – 10000) μg/l"},{"name":"砷","range":"(1,0 – 10000) μg/l"},{"name":"钡","range":"(1,0 – 10000) μg/l"},{"name":"铍","range":"(1,0 – 10000) μg/l"},{"name":"硼","range":"(50 – 10000) μg/l"},{"name":"铬","range":"(1,0 – 10000) μg/l"},{"name":"锡","range":"(1,0 – 10000) μg/l"},{"name":"锌","range":"(50 – 50000) μg/l"},{"name":"磷","range":"(0,05 – 100) mg/l"},{"name":"铝","range":"(50 – 10000) μg/l"},{"name":"镉","range":"(1,0 – 10000) μg/l"},{"name":"钴","range":"(1,0 – 10000) μg/l"},{"name":"锰","range":"(5,0 – 50000) μg/l"},{"name":"铜","range":"(5,0 – 10000) μg/l"},{"name":"钼","range":"(1,0 – 10000) μg/l"},{"name":"镍","range":"(5,0 – 10000) μg/l"},{"name":"铅","range":"(1,0 – 10000) μg/l"},{"name":"汞","range":"(0,50 – 200) μg/l"},{"name":"硒","range":"(5,0 – 10000) μg/l"},{"name":"银","range":"(5,0 – 10000) μg/l"},{"name":"锶","range":"(1,0 – 10000) μg/l"},{"name":"铊","range":"(1,0 – 10000) μg/l"},{"name":"钛","range":"( 1,0 – 10000) μg/l"},{"name":"铀","range":"(1,0 – 10000) μg/l"},{"name":"钒","range":"(5,0 – 10000) μg/l"},{"name":"铁","range":"(50 – 50000) μg/l"}],"search_zh":"废水（含雨水与融雪水） 元素浓度 锑 砷 钡 铍 硼 铬 锡 锌 磷 铝 镉 钴 锰 铜 钼 镍 铅 汞 硒 银 锶 铊 钛 铀 钒 铁 PN-EN ISO 17294-2:2024-04","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5e783f4cc76d93cba39e95","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężeni pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"wapń","range":"(0,05 – 500) mg/l"},{"name":"magnez","range":"(0,05 – 100) mg/l"},{"name":"sód","range":"(0,05 – 500) mg/l"},{"name":"potas","range":"(0,05 – 100) mg/l"},{"name":"bor","range":"(0,05 – 10) mg/l"},{"name":"glin","range":"(0,01 – 10) mg/l"},{"name":"mangan","range":"(0,005 – 100) mg/l"},{"name":"miedz","range":"(0,005 – 10) mg/l"},{"name":"żelazo","range":"(0,01 – 100) mg/l"}],"parameters_en":[{"name":"calcium","range":"(0,05 – 500) mg/l"},{"name":"magnesium","range":"(0,05 – 100) mg/l"},{"name":"sodium","range":"(0,05 – 500) mg/l"},{"name":"potassium","range":"(0,05 – 100) mg/l"},{"name":"boron","range":"(0,05 – 10) mg/l"},{"name":"aluminium","range":"(0,01 – 10) mg/l"},{"name":"manganese","range":"(0,005 – 100) mg/l"},{"name":"copper","range":"(0,005 – 10) mg/l"},{"name":"iron","range":"(0,01 – 100) mg/l"}],"technique":"Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","techniques":["Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężeni pierwiastków\nZakres:\nwapń (0,05 – 500) mg/l\nmagnez (0,05 – 100) mg/l\nsód (0,05 – 500) mg/l\npotas (0,05 – 100) mg/l\nbor (0,05 – 10) mg/l\nglin (0,01 – 10) mg/l\nmangan (0,005 – 100) mg/l\nmiedz (0,005 – 10) mg/l\nżelazo (0,01 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężeni pierwiastków\nZakres:\nwapń (0,05 – 500) mg/l\nmagnez (0,05 – 100) mg/l\nsód (0,05 – 500) mg/l\npotas (0,05 – 100) mg/l\nbor (0,05 – 10) mg/l\nglin (0,01 – 10) mg/l\nmangan (0,005 – 100) mg/l\nmiedz (0,005 – 10) mg/l\nżelazo (0,01 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi Stezeni pierwiastkow\nZakres:\nwapn (0,05 – 500) mg/l\nmagnez (0,05 – 100) mg/l\nsod (0,05 – 500) mg/l\npotas (0,05 – 100) mg/l\nbor (0,05 – 10) mg/l\nglin (0,01 – 10) mg/l\nmangan (0,005 – 100) mg/l\nmiedz (0,005 – 10) mg/l\nzelazo (0,01 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazma wzbudzona indukcyjnie (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) calcium magnesium sodium potassium boron aluminium manganese copper iron PN-EN ISO 11885:2009","search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 钙 镁 钠 钾 硼 铝 锰 铁 PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"钙","range":"(0,05 – 500) mg/l"},{"name":"镁","range":"(0,05 – 100) mg/l"},{"name":"钠","range":"(0,05 – 500) mg/l"},{"name":"钾","range":"(0,05 – 100) mg/l"},{"name":"硼","range":"(0,05 – 10) mg/l"},{"name":"铝","range":"(0,01 – 10) mg/l"},{"name":"锰","range":"(0,005 – 100) mg/l"},{"name":"miedz","range":"(0,005 – 10) mg/l"},{"name":"铁","range":"(0,01 – 100) mg/l"}],"technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）","methodology_zh":"元素浓度"},{"_id":"6a5e783f4cc76d93cba39e96","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość ogólna (z obliczeń)","methodology_en":"Total hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna (z obliczeń)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna (z obliczeń) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi Twardosc ogolna (z obliczen) PN-EN ISO 11885:2009","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total hardness (calculated) PN-EN ISO 11885:2009","search_zh":"水、生活饮用水 总硬度（由计算得出） PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水","methodology_zh":"总硬度（由计算得出）"},{"_id":"6a5e783f4cc76d93cba39e97","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"antymon","range":"(0,10 – 5000) μg/l"},{"name":"arsen","range":"(1,0 – 5000) μg/l"},{"name":"bar","range":"(1,0 – 5000) μg/l"},{"name":"beryl","range":"(0,10 – 5000) μg/l"},{"name":"bor","range":"(10 – 5000) μg/l"},{"name":"chrom","range":"(0,10 – 5000) μg/l"},{"name":"cyna","range":"(1,0 – 5000) μg/l"},{"name":"cynk","range":"(10 – 50000) μg/l"},{"name":"fosfor","range":"(0,05 – 5,0) mg/l"},{"name":"glin","range":"(10 – 5000) μg/l"},{"name":"kadm","range":"(0,10 – 5000) μg/l"},{"name":"kobalt","range":"(0,10 – 5000) μg/l"},{"name":"magnez","range":"(0,05 – 500) mg/l"},{"name":"mangan","range":"(1,0 – 50000) μg/l"},{"name":"miedź","range":"(1,0 – 5000) μg/l"},{"name":"molibden","range":"(1,0 – 5000) μg/l"},{"name":"nikiel","range":"(1,0 – 5000) μg/l"},{"name":"ołów","range":"(1,0 – 5000) μg/l"},{"name":"potas","range":"(0,05 – 500) mg/l"},{"name":"rtęć","range":"(0,10 – 50) μg/l"},{"name":"selen","range":"(1,0 – 5000) μg/l"},{"name":"srebro","range":"(1,0 – 5000) μg/l"},{"name":"sód","range":"(0,05 – 500) mg/l"},{"name":"stront","range":"(1,0 – 5000) μg/l"},{"name":"tal","range":"(0,10 – 5000) μg/l"},{"name":"tytan","range":"(1,0 – 5000) μg/l"},{"name":"uran","range":"(0,10 – 5000) μg/l"},{"name":"wanad","range":"(1,0 – 5000) μg/l"},{"name":"wapń","range":"(0,05 – 500) mg/l"},{"name":"żelazo","range":"(10 – 50000) μg/l"}],"parameters_en":[{"name":"antimony","range":"(0,10 – 5000) μg/l"},{"name":"arsenic","range":"(1,0 – 5000) μg/l"},{"name":"barium","range":"(1,0 – 5000) μg/l"},{"name":"beryllium","range":"(0,10 – 5000) μg/l"},{"name":"boron","range":"(10 – 5000) μg/l"},{"name":"chromium","range":"(0,10 – 5000) μg/l"},{"name":"tin","range":"(1,0 – 5000) μg/l"},{"name":"zinc","range":"(10 – 50000) μg/l"},{"name":"phosphorus","range":"(0,05 – 5,0) mg/l"},{"name":"aluminium","range":"(10 – 5000) μg/l"},{"name":"cadmium","range":"(0,10 – 5000) μg/l"},{"name":"cobalt","range":"(0,10 – 5000) μg/l"},{"name":"magnesium","range":"(0,05 – 500) mg/l"},{"name":"manganese","range":"(1,0 – 50000) μg/l"},{"name":"copper","range":"(1,0 – 5000) μg/l"},{"name":"molybdenum","range":"(1,0 – 5000) μg/l"},{"name":"nickel","range":"(1,0 – 5000) μg/l"},{"name":"lead","range":"(1,0 – 5000) μg/l"},{"name":"potassium","range":"(0,05 – 500) mg/l"},{"name":"mercury","range":"(0,10 – 50) μg/l"},{"name":"selenium","range":"(1,0 – 5000) μg/l"},{"name":"silver","range":"(1,0 – 5000) μg/l"},{"name":"sodium","range":"(0,05 – 500) mg/l"},{"name":"strontium","range":"(1,0 – 5000) μg/l"},{"name":"thallium","range":"(0,10 – 5000) μg/l"},{"name":"titanium","range":"(1,0 – 5000) μg/l"},{"name":"uranium","range":"(0,10 – 5000) μg/l"},{"name":"vanadium","range":"(1,0 – 5000) μg/l"},{"name":"calcium","range":"(0,05 – 500) mg/l"},{"name":"iron","range":"(10 – 50000) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-","techniques":["Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-"],"technique_en":"Inductively coupled plasma mass spectrometry method (ICP-","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nantymon (0,10 – 5000) μg/l\narsen (1,0 – 5000) μg/l\nbar (1,0 – 5000) μg/l\nberyl (0,10 – 5000) μg/l\nbor (10 – 5000) μg/l\nchrom (0,10 – 5000) μg/l\ncyna (1,0 – 5000) μg/l\ncynk (10 – 50000) μg/l\nfosfor (0,05 – 5,0) mg/l\nglin (10 – 5000) μg/l\nkadm (0,10 – 5000) μg/l\nkobalt (0,10 – 5000) μg/l\nmagnez (0,05 – 500) mg/l\nmangan (1,0 – 50000) μg/l\nmiedź (1,0 – 5000) μg/l\nmolibden (1,0 – 5000) μg/l\nnikiel (1,0 – 5000) μg/l\nołów (1,0 – 5000) μg/l\npotas (0,05 – 500) mg/l\nrtęć (0,10 – 50) μg/l\nselen (1,0 – 5000) μg/l\nsrebro (1,0 – 5000) μg/l\nsód (0,05 – 500) mg/l\nstront (1,0 – 5000) μg/l\ntal (0,10 – 5000) μg/l\ntytan (1,0 – 5000) μg/l\nuran (0,10 – 5000) μg/l\nwanad (1,0 – 5000) μg/l\nwapń (0,05 – 500) mg/l\nżelazo (10 – 50000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP-","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nantymon (0,10 – 5000) μg/l\narsen (1,0 – 5000) μg/l\nbar (1,0 – 5000) μg/l\nberyl (0,10 – 5000) μg/l\nbor (10 – 5000) μg/l\nchrom (0,10 – 5000) μg/l\ncyna (1,0 – 5000) μg/l\ncynk (10 – 50000) μg/l\nfosfor (0,05 – 5,0) mg/l\nglin (10 – 5000) μg/l\nkadm (0,10 – 5000) μg/l\nkobalt (0,10 – 5000) μg/l\nmagnez (0,05 – 500) mg/l\nmangan (1,0 – 50000) μg/l\nmiedź (1,0 – 5000) μg/l\nmolibden (1,0 – 5000) μg/l\nnikiel (1,0 – 5000) μg/l\nołów (1,0 – 5000) μg/l\npotas (0,05 – 500) mg/l\nrtęć (0,10 – 50) μg/l\nselen (1,0 – 5000) μg/l\nsrebro (1,0 – 5000) μg/l\nsód (0,05 – 500) mg/l\nstront (1,0 – 5000) μg/l\ntal (0,10 – 5000) μg/l\ntytan (1,0 – 5000) μg/l\nuran (0,10 – 5000) μg/l\nwanad (1,0 – 5000) μg/l\nwapń (0,05 – 500) mg/l\nżelazo (10 – 50000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzężonej (ICP- PN-EN ISO 17294-2:2024-04 Woda, woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nantymon (0,10 – 5000) μg/l\narsen (1,0 – 5000) μg/l\nbar (1,0 – 5000) μg/l\nberyl (0,10 – 5000) μg/l\nbor (10 – 5000) μg/l\nchrom (0,10 – 5000) μg/l\ncyna (1,0 – 5000) μg/l\ncynk (10 – 50000) μg/l\nfosfor (0,05 – 5,0) mg/l\nglin (10 – 5000) μg/l\nkadm (0,10 – 5000) μg/l\nkobalt (0,10 – 5000) μg/l\nmagnez (0,05 – 500) mg/l\nmangan (1,0 – 50000) μg/l\nmiedz (1,0 – 5000) μg/l\nmolibden (1,0 – 5000) μg/l\nnikiel (1,0 – 5000) μg/l\nolow (1,0 – 5000) μg/l\npotas (0,05 – 500) mg/l\nrtec (0,10 – 50) μg/l\nselen (1,0 – 5000) μg/l\nsrebro (1,0 – 5000) μg/l\nsod (0,05 – 500) mg/l\nstront (1,0 – 5000) μg/l\ntal (0,10 – 5000) μg/l\ntytan (1,0 – 5000) μg/l\nuran (0,10 – 5000) μg/l\nwanad (1,0 – 5000) μg/l\nwapn (0,05 – 500) mg/l\nzelazo (10 – 50000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP- PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Element concentration Inductively coupled plasma mass spectrometry method (ICP- antimony arsenic barium beryllium boron chromium tin zinc phosphorus aluminium cadmium cobalt magnesium manganese copper molybdenum nickel lead potassium mercury selenium silver sodium strontium thallium titanium uranium vanadium calcium iron PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"锑","range":"(0,10 – 5000) μg/l"},{"name":"砷","range":"(1,0 – 5000) μg/l"},{"name":"钡","range":"(1,0 – 5000) μg/l"},{"name":"铍","range":"(0,10 – 5000) μg/l"},{"name":"硼","range":"(10 – 5000) μg/l"},{"name":"铬","range":"(0,10 – 5000) μg/l"},{"name":"锡","range":"(1,0 – 5000) μg/l"},{"name":"锌","range":"(10 – 50000) μg/l"},{"name":"磷","range":"(0,05 – 5,0) mg/l"},{"name":"铝","range":"(10 – 5000) μg/l"},{"name":"镉","range":"(0,10 – 5000) μg/l"},{"name":"钴","range":"(0,10 – 5000) μg/l"},{"name":"镁","range":"(0,05 – 500) mg/l"},{"name":"锰","range":"(1,0 – 50000) μg/l"},{"name":"铜","range":"(1,0 – 5000) μg/l"},{"name":"钼","range":"(1,0 – 5000) μg/l"},{"name":"镍","range":"(1,0 – 5000) μg/l"},{"name":"铅","range":"(1,0 – 5000) μg/l"},{"name":"钾","range":"(0,05 – 500) mg/l"},{"name":"汞","range":"(0,10 – 50) μg/l"},{"name":"硒","range":"(1,0 – 5000) μg/l"},{"name":"银","range":"(1,0 – 5000) μg/l"},{"name":"钠","range":"(0,05 – 500) mg/l"},{"name":"锶","range":"(1,0 – 5000) μg/l"},{"name":"铊","range":"(0,10 – 5000) μg/l"},{"name":"钛","range":"(1,0 – 5000) μg/l"},{"name":"铀","range":"(0,10 – 5000) μg/l"},{"name":"钒","range":"(1,0 – 5000) μg/l"},{"name":"钙","range":"(0,05 – 500) mg/l"},{"name":"铁","range":"(10 – 50000) μg/l"}],"search_zh":"水、生活饮用水 元素浓度 锑 砷 钡 铍 硼 铬 锡 锌 磷 铝 镉 钴 镁 锰 铜 钼 镍 铅 钾 汞 硒 银 钠 锶 铊 钛 铀 钒 钙 铁 PN-EN ISO 17294-2:2024-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e98","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"MS)","methodology_en":"MS)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi MS) PN-EN ISO 17294-2:2024-04 Woda, woda do spozycia przez ludzi MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption MS) PN-EN ISO 17294-2:2024-04","search_zh":"水、生活饮用水 PN-EN ISO 17294-2:2024-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39e99","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 – 5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 5) mg/l"}],"technique":"Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","techniques":["Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 5) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,05 – 5) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie fosforu ogolnego\nZakres (0,05 – 5) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazma wzbudzona indukcyjnie (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total phosphorus concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 5) mg/l"}],"search_zh":"水 总磷浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","test_object_zh":"水","technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）"},{"_id":"6a5e783f4cc76d93cba39e9a","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężeni pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"arsen","range":"(0,05 – 2) mg/l"},{"name":"bar","range":"(0,005 – 5) mg/l"},{"name":"bor","range":"(0,05 – 10) mg/l"},{"name":"chrom","range":"(0,005 – 10) mg/l"},{"name":"cyna","range":"(0,03 – 2) mg/l"},{"name":"cynk","range":"(0,01 – 10) mg/l"},{"name":"glin","range":"(0,01 – 10) mg/l"},{"name":"kadm","range":"(0,005 – 10) mg/l"},{"name":"kobalt","range":"(0,005 – 10) mg/l"},{"name":"mangan","range":"(0,005 – 100) mg/l"},{"name":"miedz","range":"(0,005 – 10) mg/l"},{"name":"molibden","range":"(0,005 – 10) mg/l"},{"name":"nikiel","range":"(0,01 – 10) mg/l"},{"name":"ołów","range":"(0,05 – 10) mg/l"},{"name":"srebro","range":"(0,005 – 10) mg/l"},{"name":"wanad","range":"(0,005 – 10) mg/l"},{"name":"żelazo","range":"(0,01 – 100) mg/l"}],"parameters_en":[{"name":"arsenic","range":"(0,05 – 2) mg/l"},{"name":"barium","range":"(0,005 – 5) mg/l"},{"name":"boron","range":"(0,05 – 10) mg/l"},{"name":"chromium","range":"(0,005 – 10) mg/l"},{"name":"tin","range":"(0,03 – 2) mg/l"},{"name":"zinc","range":"(0,01 – 10) mg/l"},{"name":"aluminium","range":"(0,01 – 10) mg/l"},{"name":"cadmium","range":"(0,005 – 10) mg/l"},{"name":"cobalt","range":"(0,005 – 10) mg/l"},{"name":"manganese","range":"(0,005 – 100) mg/l"},{"name":"copper","range":"(0,005 – 10) mg/l"},{"name":"molybdenum","range":"(0,005 – 10) mg/l"},{"name":"nickel","range":"(0,01 – 10) mg/l"},{"name":"lead","range":"(0,05 – 10) mg/l"},{"name":"silver","range":"(0,005 – 10) mg/l"},{"name":"vanadium","range":"(0,005 – 10) mg/l"},{"name":"iron","range":"(0,01 – 100) mg/l"}],"technique":"Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","techniques":["Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężeni pierwiastków\nZakres:\narsen (0,05 – 2) mg/l\nbar (0,005 – 5) mg/l\nbor (0,05 – 10) mg/l\nchrom (0,005 – 10) mg/l\ncyna (0,03 – 2) mg/l\ncynk (0,01 – 10) mg/l\nglin (0,01 – 10) mg/l\nkadm (0,005 – 10) mg/l\nkobalt (0,005 – 10) mg/l\nmangan (0,005 – 100) mg/l\nmiedz (0,005 – 10) mg/l\nmolibden (0,005 – 10) mg/l\nnikiel (0,01 – 10) mg/l\nołów (0,05 – 10) mg/l\nsrebro (0,005 – 10) mg/l\nwanad (0,005 – 10) mg/l\nżelazo (0,01 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężeni pierwiastków\nZakres:\narsen (0,05 – 2) mg/l\nbar (0,005 – 5) mg/l\nbor (0,05 – 10) mg/l\nchrom (0,005 – 10) mg/l\ncyna (0,03 – 2) mg/l\ncynk (0,01 – 10) mg/l\nglin (0,01 – 10) mg/l\nkadm (0,005 – 10) mg/l\nkobalt (0,005 – 10) mg/l\nmangan (0,005 – 100) mg/l\nmiedz (0,005 – 10) mg/l\nmolibden (0,005 – 10) mg/l\nnikiel (0,01 – 10) mg/l\nołów (0,05 – 10) mg/l\nsrebro (0,005 – 10) mg/l\nwanad (0,005 – 10) mg/l\nżelazo (0,01 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezeni pierwiastkow\nZakres:\narsen (0,05 – 2) mg/l\nbar (0,005 – 5) mg/l\nbor (0,05 – 10) mg/l\nchrom (0,005 – 10) mg/l\ncyna (0,03 – 2) mg/l\ncynk (0,01 – 10) mg/l\nglin (0,01 – 10) mg/l\nkadm (0,005 – 10) mg/l\nkobalt (0,005 – 10) mg/l\nmangan (0,005 – 100) mg/l\nmiedz (0,005 – 10) mg/l\nmolibden (0,005 – 10) mg/l\nnikiel (0,01 – 10) mg/l\nolow (0,05 – 10) mg/l\nsrebro (0,005 – 10) mg/l\nwanad (0,005 – 10) mg/l\nzelazo (0,01 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazma wzbudzona indukcyjnie (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic barium boron chromium tin zinc aluminium cadmium cobalt manganese copper molybdenum nickel lead silver vanadium iron PN-EN ISO 11885:2009","parameters_zh":[{"name":"砷","range":"(0,05 – 2) mg/l"},{"name":"钡","range":"(0,005 – 5) mg/l"},{"name":"硼","range":"(0,05 – 10) mg/l"},{"name":"铬","range":"(0,005 – 10) mg/l"},{"name":"锡","range":"(0,03 – 2) mg/l"},{"name":"锌","range":"(0,01 – 10) mg/l"},{"name":"铝","range":"(0,01 – 10) mg/l"},{"name":"镉","range":"(0,005 – 10) mg/l"},{"name":"钴","range":"(0,005 – 10) mg/l"},{"name":"锰","range":"(0,005 – 100) mg/l"},{"name":"miedz","range":"(0,005 – 10) mg/l"},{"name":"钼","range":"(0,005 – 10) mg/l"},{"name":"镍","range":"(0,01 – 10) mg/l"},{"name":"铅","range":"(0,05 – 10) mg/l"},{"name":"银","range":"(0,005 – 10) mg/l"},{"name":"钒","range":"(0,005 – 10) mg/l"},{"name":"铁","range":"(0,01 – 100) mg/l"}],"search_zh":"水、废水 元素浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 砷 钡 硼 铬 锡 锌 铝 镉 钴 锰 钼 镍 铅 银 钒 铁 PN-EN ISO 11885:2009","test_object_zh":"水、废水","technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）","methodology_zh":"元素浓度"},{"_id":"6a5e783f4cc76d93cba39e9b","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"technique":"Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","techniques":["Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES) PN-EN ISO 11885:2009 Scieki (w tym wody opadowe i roztopowe) Stezenie fosforu ogolnego\nZakres (0,05 – 100) mg/l\nMetoda optycznej spektrometrii emisyjnej z plazma wzbudzona indukcyjnie (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Total phosphorus concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"废水（含雨水与融雪水） 总磷浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","test_object_zh":"废水（含雨水与融雪水）","technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）"},{"_id":"6a5e783f4cc76d93cba39e9c","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,1 – 50) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,1 – 50) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)"],"technique_en":"Mercury cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,1 – 50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","reference":"PN-EN ISO 54321:2021-07 | PN-EN 16175-1:2017-02","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN 16175-1:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,1 – 50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS) PN-EN ISO 54321:2021-07 | PN-EN 16175-1:2017-02 Osady sciekowe Zawartosc rteci\nZakres (0,1 – 50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rteci (CVAAS) PN-EN ISO 54321:2021-07 | PN-EN 16175-1:2017-02","categories":["water"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Mercury content Mercury cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 54321:2021-07 | PN-EN 16175-1:2017-02","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,1 – 50) mg/kg"}],"search_zh":"污泥 汞含量 汞冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 54321:2021-07 | PN-EN 16175-1:2017-02","test_object_zh":"污泥","technique_zh":"汞冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a5e783f4cc76d93cba39e9d","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Stężeni pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"miedź","range":"(2 – 4000) mg/kg"},{"name":"cynk","range":"(5 – 10000) mg/kg"},{"name":"kadm","range":"(2 – 100) mg/kg"},{"name":"ołów","range":"(5 – 3000) mg/kg"},{"name":"chrom","range":"(2 – 5000) mg/kg"},{"name":"nikiel","range":"(2 – 1000) mg/kg"},{"name":"wapń","range":"(25 – 200000) mg/kg"},{"name":"Zakres","range":"(0,0025 – 20) % s.m."},{"name":"magnez","range":"(25 - 100000) mg/kg"},{"name":"(0,0025 – 10) % s.m."},{"name":"fosfor ogólny","range":"(5 – 200000) mg/kg"},{"name":"(0,0005 – 20) % s.m."}],"parameters_en":[{"name":"copper","range":"(2 – 4000) mg/kg"},{"name":"zinc","range":"(5 – 10000) mg/kg"},{"name":"cadmium","range":"(2 – 100) mg/kg"},{"name":"lead","range":"(5 – 3000) mg/kg"},{"name":"chromium","range":"(2 – 5000) mg/kg"},{"name":"nickel","range":"(2 – 1000) mg/kg"},{"name":"calcium","range":"(25 – 200000) mg/kg"},{"name":"Range","range":"(0,0025 – 20) % s.m."},{"name":"magnesium","range":"(25 - 100000) mg/kg"},{"name":"(0,0025 – 10) % d.m."},{"name":"total phosphorus","range":"(5 – 200000) mg/kg"},{"name":"(0,0005 – 20) % d.m."}],"technique":"Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","techniques":["Metoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężeni pierwiastków\nZakres:\nmiedź (2 – 4000) mg/kg\ncynk (5 – 10000) mg/kg\nkadm (2 – 100) mg/kg\nołów (5 – 3000) mg/kg\nchrom (2 – 5000) mg/kg\nnikiel (2 – 1000) mg/kg\nwapń (25 – 200000) mg/kg\nZakres (0,0025 – 20) % s.m.\nmagnez (25 - 100000) mg/kg\n(0,0025 – 10) % s.m.\nfosfor ogólny (5 – 200000) mg/kg\n(0,0005 – 20) % s.m.\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN EN ISO 54321:2021","norm_bases":["PN-EN ISO 11885:2009","PN EN ISO 54321:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Stężeni pierwiastków\nZakres:\nmiedź (2 – 4000) mg/kg\ncynk (5 – 10000) mg/kg\nkadm (2 – 100) mg/kg\nołów (5 – 3000) mg/kg\nchrom (2 – 5000) mg/kg\nnikiel (2 – 1000) mg/kg\nwapń (25 – 200000) mg/kg\nZakres (0,0025 – 20) % s.m.\nmagnez (25 - 100000) mg/kg\n(0,0025 – 10) % s.m.\nfosfor ogólny (5 – 200000) mg/kg\n(0,0005 – 20) % s.m.\nMetoda optycznej spektrometrii emisyjnej z plazmą wzbudzoną indukcyjnie (ICP-OES) PN-EN ISO 11885:2009 | PN EN ISO 54321:2021 Osady sciekowe Stezeni pierwiastkow\nZakres:\nmiedz (2 – 4000) mg/kg\ncynk (5 – 10000) mg/kg\nkadm (2 – 100) mg/kg\nolow (5 – 3000) mg/kg\nchrom (2 – 5000) mg/kg\nnikiel (2 – 1000) mg/kg\nwapn (25 – 200000) mg/kg\nZakres (0,0025 – 20) % s.m.\nmagnez (25 - 100000) mg/kg\n(0,0025 – 10) % s.m.\nfosfor ogolny (5 – 200000) mg/kg\n(0,0005 – 20) % s.m.\nMetoda optycznej spektrometrii emisyjnej z plazma wzbudzona indukcyjnie (ICP-OES) PN-EN ISO 11885:2009 | PN EN ISO 54321:2021","categories":["water","materials"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) copper zinc cadmium lead chromium nickel calcium Range magnesium (0,0025 – 10) % d.m. total phosphorus (0,0005 – 20) % d.m. PN-EN ISO 11885:2009 | PN EN ISO 54321:2021","parameters_zh":[{"name":"铜","range":"(2 – 4000) mg/kg"},{"name":"锌","range":"(5 – 10000) mg/kg"},{"name":"镉","range":"(2 – 100) mg/kg"},{"name":"铅","range":"(5 – 3000) mg/kg"},{"name":"铬","range":"(2 – 5000) mg/kg"},{"name":"镍","range":"(2 – 1000) mg/kg"},{"name":"钙","range":"(25 – 200000) mg/kg"},{"name":"范围","range":"(0,0025 – 20) % s.m."},{"name":"镁","range":"(25 - 100000) mg/kg"},{"name":"(0,0025 – 10) % s.m."},{"name":"总磷","range":"(5 – 200000) mg/kg"},{"name":"(0,0005 – 20) % s.m."}],"search_zh":"污泥 元素浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 铜 锌 镉 铅 铬 镍 钙 范围 镁 总磷 PN-EN ISO 11885:2009 | PN EN ISO 54321:2021","test_object_zh":"污泥","technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）","methodology_zh":"元素浓度"},{"_id":"6a5e783f4cc76d93cba39e9e","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters":[{"name":"fluoranten","range":"(2,0 – 100) ng/l"},{"name":"benzo(b)fluoranten","range":"(2,0 – 100) ng/l"},{"name":"benzo(k)fluoranten","range":"(2,0 – 100) ng/l"},{"name":"benzo(a)piren","range":"(2,0 – 100) ng/l"},{"name":"benzo(ghi)perylen","range":"(2,0 – 100) ng/l"},{"name":"indeno(1,2,3-c,d)piren","range":"(2,0 – 100) ng/l"}],"parameters_en":[{"name":"fluoranthene","range":"(2,0 – 100) ng/l"},{"name":"benzo(b)fluoranthene","range":"(2,0 – 100) ng/l"},{"name":"benzo(k)fluoranthene","range":"(2,0 – 100) ng/l"},{"name":"benzo(a)pyrene","range":"(2,0 – 100) ng/l"},{"name":"benzo(ghi)perylene","range":"(2,0 – 100) ng/l"},{"name":"indeno(1,2,3-c,d)pyrene","range":"(2,0 – 100) ng/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nfluoranten (2,0 – 100) ng/l\nbenzo(b)fluoranten (2,0 – 100) ng/l\nbenzo(k)fluoranten (2,0 – 100) ng/l\nbenzo(a)piren (2,0 – 100) ng/l\nbenzo(ghi)perylen (2,0 – 100) ng/l\nindeno(1,2,3-c,d)piren (2,0 – 100) ng/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-18 wyd.11 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nfluoranten (2,0 – 100) ng/l\nbenzo(b)fluoranten (2,0 – 100) ng/l\nbenzo(k)fluoranten (2,0 – 100) ng/l\nbenzo(a)piren (2,0 – 100) ng/l\nbenzo(ghi)perylen (2,0 – 100) ng/l\nindeno(1,2,3-c,d)piren (2,0 – 100) ng/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nfluoranten (2,0 – 100) ng/l\nbenzo(b)fluoranten (2,0 – 100) ng/l\nbenzo(k)fluoranten (2,0 – 100) ng/l\nbenzo(a)piren (2,0 – 100) ng/l\nbenzo(ghi)perylen (2,0 – 100) ng/l\nindeno(1,2,3-c,d)piren (2,0 – 100) ng/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene indeno(1,2,3-c,d)pyrene GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","search_zh":"水、生活饮用水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 荧蒽 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 苯并（ghi）苝 茚并(1,2,3-c,d)芘 GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"荧蒽","range":"(2,0 – 100) ng/l"},{"name":"苯并（b）荧蒽","range":"(2,0 – 100) ng/l"},{"name":"苯并（k）荧蒽","range":"(2,0 – 100) ng/l"},{"name":"苯并（a）芘","range":"(2,0 – 100) ng/l"},{"name":"苯并（ghi）苝","range":"(2,0 – 100) ng/l"},{"name":"茚并(1,2,3-c,d)芘","range":"(2,0 – 100) ng/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a5e783f4cc76d93cba39e9f","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma WWA (z obliczeń)","methodology_en":"Sum of PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma WWA (z obliczeń)","reference":"GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-18 wyd.11 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma WWA (z obliczeń) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Suma WWA (z obliczen) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sum of PAH (calculated) GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","search_zh":"水、生活饮用水 多环芳烃总量（计算值） GdW/SL/PB-18 wyd.11 z dnia 01.09.2023","test_object_zh":"水、生活饮用水","methodology_zh":"多环芳烃总量（计算值）"},{"_id":"6a5e783f4cc76d93cba39ea0","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie akryloamidu","methodology_en":"Acrylamide concentration","parameters":[{"name":"Zakres","range":"(0,050 – 1,0) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 1,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie akryloamidu\nZakres (0,050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"GdW/SL/PB-70 wyd.05 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-70 wyd.05 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie akryloamidu\nZakres (0,050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) GdW/SL/PB-70 wyd.05 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Stezenie akryloamidu\nZakres (0,050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) GdW/SL/PB-70 wyd.05 z dnia 01.09.2023","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Acrylamide concentration Gas chromatography with electron capture detection (GC-ECD) Range GdW/SL/PB-70 wyd.05 z dnia 01.09.2023","parameters_zh":[{"name":"范围","range":"(0,050 – 1,0) μg/l"}],"search_zh":"水、生活饮用水 丙烯酰胺浓度 气相色谱-电子捕获检测法（GC-ECD） 范围 GdW/SL/PB-70 wyd.05 z dnia 01.09.2023","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水","methodology_zh":"丙烯酰胺浓度"},{"_id":"6a5e783f4cc76d93cba39ea1","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie epichlorohydryny","methodology_en":"Epichlorohydrin concentration","parameters":[{"name":"Zakres","range":"(0,050 – 1,0) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 1,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie epichlorohydryny\nZakres (0,050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025","norm_bases":["GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie epichlorohydryny\nZakres (0,050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025 Woda, woda do spozycia przez ludzi Stezenie epichlorohydryny\nZakres (0,050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025","categories":["water"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Epichlorohydrin concentration Gas chromatography with mass spectrometry detection (GC-MS) Range GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025","parameters_zh":[{"name":"范围","range":"(0,050 – 1,0) μg/l"}],"search_zh":"水、生活饮用水 环氧氯丙烷浓度 气相色谱-质谱法（GC-MS） 范围 GdW/SL/PB-71 wyd. 06 z dnia 10.06.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水","methodology_zh":"环氧氯丙烷浓度"},{"_id":"6a5e783f4cc76d93cba39ea2","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie pestycydów triazynowych i mocznikowych","methodology_en":"Concentration of triazine and urea pesticides","parameters":[{"name":"atrazyna","range":"(5,0 –100) ng/l"},{"name":"deetyloatrazyna","range":"(5,0 –100) ng/l"},{"name":"symazyna","range":"(5,0 –100) ng/l"},{"name":"cyjanazyna","range":"(5,0 –100) ng/l"},{"name":"sebutylazyna","range":"(5,0 –100) ng/l"},{"name":"terbutyloazyna","range":"(5,0 –100) ng/l"},{"name":"metoksuron","range":"(5,0 –100) ng/l"},{"name":"heksazynon","range":"(5,0 –100) ng/l"},{"name":"metabenztiazuron","range":"(5,0 –100) ng/l"},{"name":"chlortoluron","range":"(5,0 –100) ng/l"},{"name":"monolinuron","range":"(5,0 –100) ng/l"},{"name":"diuron","range":"(5,0 –100) ng/l"},{"name":"isoproturon","range":"(5,0 –100) ng/l"},{"name":"metobromuron","range":"(5,0 –100) ng/l"},{"name":"metazachlor","range":"(5,0 –100) ng/l"},{"name":"linuron","range":"(5,0 –100) ng/l"},{"name":"metolachlor","range":"(5,0 –100) ng/l"}],"parameters_en":[{"name":"atrazine","range":"(5,0 –100) ng/l"},{"name":"desethylatrazine","range":"(5,0 –100) ng/l"},{"name":"simazine","range":"(5,0 –100) ng/l"},{"name":"cyanazine","range":"(5,0 –100) ng/l"},{"name":"sebuthylazine","range":"(5,0 –100) ng/l"},{"name":"terbuthylazine","range":"(5,0 –100) ng/l"},{"name":"metoxuron","range":"(5,0 –100) ng/l"},{"name":"hexazinone","range":"(5,0 –100) ng/l"},{"name":"metabenzthiazuron","range":"(5,0 –100) ng/l"},{"name":"chlortoluron","range":"(5,0 –100) ng/l"},{"name":"monolinuron","range":"(5,0 –100) ng/l"},{"name":"diuron","range":"(5,0 –100) ng/l"},{"name":"isoproturon","range":"(5,0 –100) ng/l"},{"name":"metobromuron","range":"(5,0 –100) ng/l"},{"name":"metazachlor","range":"(5,0 –100) ng/l"},{"name":"linuron","range":"(5,0 –100) ng/l"},{"name":"metolachlor","range":"(5,0 –100) ng/l"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie pestycydów triazynowych i mocznikowych\nZakres:\natrazyna (5,0 –100) ng/l\ndeetyloatrazyna (5,0 –100) ng/l\nsymazyna (5,0 –100) ng/l\ncyjanazyna (5,0 –100) ng/l\nsebutylazyna (5,0 –100) ng/l\nterbutyloazyna (5,0 –100) ng/l\nmetoksuron (5,0 –100) ng/l\nheksazynon (5,0 –100) ng/l\nmetabenztiazuron (5,0 –100) ng/l\nchlortoluron (5,0 –100) ng/l\nmonolinuron (5,0 –100) ng/l\ndiuron (5,0 –100) ng/l\nisoproturon (5,0 –100) ng/l\nmetobromuron (5,0 –100) ng/l\nmetazachlor (5,0 –100) ng/l\nlinuron (5,0 –100) ng/l\nmetolachlor (5,0 –100) ng/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC MS-MS)","reference":"GdW/SL/PB-73 wyd.03 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-73 wyd.03 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pestycydów triazynowych i mocznikowych\nZakres:\natrazyna (5,0 –100) ng/l\ndeetyloatrazyna (5,0 –100) ng/l\nsymazyna (5,0 –100) ng/l\ncyjanazyna (5,0 –100) ng/l\nsebutylazyna (5,0 –100) ng/l\nterbutyloazyna (5,0 –100) ng/l\nmetoksuron (5,0 –100) ng/l\nheksazynon (5,0 –100) ng/l\nmetabenztiazuron (5,0 –100) ng/l\nchlortoluron (5,0 –100) ng/l\nmonolinuron (5,0 –100) ng/l\ndiuron (5,0 –100) ng/l\nisoproturon (5,0 –100) ng/l\nmetobromuron (5,0 –100) ng/l\nmetazachlor (5,0 –100) ng/l\nlinuron (5,0 –100) ng/l\nmetolachlor (5,0 –100) ng/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC MS-MS) GdW/SL/PB-73 wyd.03 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Stezenie pestycydow triazynowych i mocznikowych\nZakres:\natrazyna (5,0 –100) ng/l\ndeetyloatrazyna (5,0 –100) ng/l\nsymazyna (5,0 –100) ng/l\ncyjanazyna (5,0 –100) ng/l\nsebutylazyna (5,0 –100) ng/l\nterbutyloazyna (5,0 –100) ng/l\nmetoksuron (5,0 –100) ng/l\nheksazynon (5,0 –100) ng/l\nmetabenztiazuron (5,0 –100) ng/l\nchlortoluron (5,0 –100) ng/l\nmonolinuron (5,0 –100) ng/l\ndiuron (5,0 –100) ng/l\nisoproturon (5,0 –100) ng/l\nmetobromuron (5,0 –100) ng/l\nmetazachlor (5,0 –100) ng/l\nlinuron (5,0 –100) ng/l\nmetolachlor (5,0 –100) ng/l\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC MS-MS) GdW/SL/PB-73 wyd.03 z dnia 01.09.2023","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of triazine and urea pesticides Liquid chromatography with tandem mass spectrometry detection (LC MS-MS) atrazine desethylatrazine simazine cyanazine sebuthylazine terbuthylazine metoxuron hexazinone metabenzthiazuron chlortoluron monolinuron diuron isoproturon metobromuron metazachlor linuron metolachlor GdW/SL/PB-73 wyd.03 z dnia 01.09.2023","search_zh":"水、生活饮用水 莠去津 西玛津 敌草隆 利谷隆 GdW/SL/PB-73 wyd.03 z dnia 01.09.2023","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"莠去津","range":"(5,0 –100) ng/l"},{"name":"deetyloatrazyna","range":"(5,0 –100) ng/l"},{"name":"西玛津","range":"(5,0 –100) ng/l"},{"name":"cyjanazyna","range":"(5,0 –100) ng/l"},{"name":"sebutylazyna","range":"(5,0 –100) ng/l"},{"name":"terbutyloazyna","range":"(5,0 –100) ng/l"},{"name":"metoksuron","range":"(5,0 –100) ng/l"},{"name":"heksazynon","range":"(5,0 –100) ng/l"},{"name":"metabenztiazuron","range":"(5,0 –100) ng/l"},{"name":"chlortoluron","range":"(5,0 –100) ng/l"},{"name":"monolinuron","range":"(5,0 –100) ng/l"},{"name":"敌草隆","range":"(5,0 –100) ng/l"},{"name":"isoproturon","range":"(5,0 –100) ng/l"},{"name":"metobromuron","range":"(5,0 –100) ng/l"},{"name":"metazachlor","range":"(5,0 –100) ng/l"},{"name":"利谷隆","range":"(5,0 –100) ng/l"},{"name":"metolachlor","range":"(5,0 –100) ng/l"}]},{"_id":"6a5e783f4cc76d93cba39ea3","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"bromiany","range":"(0,003 – 0,025) mg/l"}],"parameters_en":[{"name":"bromates","range":"(0,003 – 0,025) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nbromiany (0,003 – 0,025) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nbromiany (0,003 – 0,025) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 15061:2003 Woda, woda do spozycia przez ludzi Stezenie anionow\nbromiany (0,003 – 0,025) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) bromates PN-EN ISO 15061:2003","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 15061:2003","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ea4","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"chloryny","range":"(0,010 – 6,0) mg/l"},{"name":"chlorany","range":"(0,010 – 6,0) mg/l"}],"parameters_en":[{"name":"chlorites","range":"(0,010 – 6,0) mg/l"},{"name":"chlorates","range":"(0,010 – 6,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nchloryny (0,010 – 6,0) mg/l\nchlorany (0,010 – 6,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nchloryny (0,010 – 6,0) mg/l\nchlorany (0,010 – 6,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nchloryny (0,010 – 6,0) mg/l\nchlorany (0,010 – 6,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorites chlorates PN-EN ISO 10304-4:2022-08","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 亚氯酸盐 氯酸盐 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"亚氯酸盐","range":"(0,010 – 6,0) mg/l"},{"name":"氯酸盐","range":"(0,010 – 6,0) mg/l"}]},{"_id":"6a5e783f4cc76d93cba39ea5","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma chloranów i chlorynów (z obliczeń)","methodology_en":"Sum of chlorates and chlorites (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Suma chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08","search_zh":"水、生活饮用水 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐与亚氯酸盐总量（由计算得出）"},{"_id":"6a5e783f4cc76d93cba39ea6","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"bromki","range":"(0,010 – 4,0) mg/l"},{"name":"chlorki","range":"(1,0 – 5000) mg/l"},{"name":"fluorki","range":"(0,020 – 10,0) mg/l"},{"name":"azotany","range":"(0,20 – 50,0) mg/l"},{"name":"azotyny","range":"(0,003 – 6,00) mg/l"},{"name":"o-fosforany","range":"(0,020 – 25,0) mg/l"},{"name":"siarczany","range":"(1,0 – 3500) mg/l"}],"parameters_en":[{"name":"bromides","range":"(0,010 – 4,0) mg/l"},{"name":"chlorides","range":"(1,0 – 5000) mg/l"},{"name":"fluorides","range":"(0,020 – 10,0) mg/l"},{"name":"nitrates","range":"(0,20 – 50,0) mg/l"},{"name":"nitrites","range":"(0,003 – 6,00) mg/l"},{"name":"orthophosphates","range":"(0,020 – 25,0) mg/l"},{"name":"sulfates","range":"(1,0 – 3500) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nbromki (0,010 – 4,0) mg/l\nchlorki (1,0 – 5000) mg/l\nfluorki (0,020 – 10,0) mg/l\nazotany (0,20 – 50,0) mg/l\nazotyny (0,003 – 6,00) mg/l\no-fosforany (0,020 – 25,0) mg/l\nsiarczany (1,0 – 3500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC 2012","norm_bases":["PN-EN ISO 10304-1:2009+AC 2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nbromki (0,010 – 4,0) mg/l\nchlorki (1,0 – 5000) mg/l\nfluorki (0,020 – 10,0) mg/l\nazotany (0,20 – 50,0) mg/l\nazotyny (0,003 – 6,00) mg/l\no-fosforany (0,020 – 25,0) mg/l\nsiarczany (1,0 – 3500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC 2012 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nbromki (0,010 – 4,0) mg/l\nchlorki (1,0 – 5000) mg/l\nfluorki (0,020 – 10,0) mg/l\nazotany (0,20 – 50,0) mg/l\nazotyny (0,003 – 6,00) mg/l\no-fosforany (0,020 – 25,0) mg/l\nsiarczany (1,0 – 3500) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC 2012","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) bromides chlorides fluorides nitrates nitrites orthophosphates sulfates PN-EN ISO 10304-1:2009+AC 2012","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 溴化物 氯化物 氟化物 硝酸盐 亚硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009+AC 2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"溴化物","range":"(0,010 – 4,0) mg/l"},{"name":"氯化物","range":"(1,0 – 5000) mg/l"},{"name":"氟化物","range":"(0,020 – 10,0) mg/l"},{"name":"硝酸盐","range":"(0,20 – 50,0) mg/l"},{"name":"亚硝酸盐","range":"(0,003 – 6,00) mg/l"},{"name":"o-fosforany","range":"(0,020 – 25,0) mg/l"},{"name":"硫酸盐","range":"(1,0 – 3500) mg/l"}]},{"_id":"6a5e783f4cc76d93cba39ea7","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie kwasów halogenooctowych (HAA)","methodology_en":"Haloacetic acid (HAA) concentration","parameters":[{"name":"kw. monochlorooctowy MCAA"},{"name":"Zakres","range":"(5,0 – 100) ng/l"},{"name":"kw. monobromooctowy MBAA","range":"(5,0 – 100 ng/l)"},{"name":"kw. dichlorooctowy DCAA","range":"(5,0 – 100 ng/l)"},{"name":"kw. dibromooctowy DBAA","range":"(5,0 – 100 ng/l)"},{"name":"kw. trichlorooctowy TCAA","range":"(5,0 – 100 ng/l)"}],"parameters_en":[{"name":"monochloroacetic acid MCAA"},{"name":"Range","range":"(5,0 – 100) ng/l"},{"name":"monobromoacetic acid MBAA","range":"(5,0 – 100 ng/l)"},{"name":"dichloroacetic acid DCAA","range":"(5,0 – 100 ng/l)"},{"name":"dibromoacetic acid DBAA","range":"(5,0 – 100 ng/l)"},{"name":"trichloroacetic acid TCAA","range":"(5,0 – 100 ng/l)"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie kwasów halogenooctowych (HAA)\nZakres:\nkw. monochlorooctowy MCAA\nZakres (5,0 – 100) ng/l\nkw. monobromooctowy MBAA (5,0 – 100 ng/l)\nkw. dichlorooctowy DCAA (5,0 – 100 ng/l)\nkw. dibromooctowy DBAA (5,0 – 100 ng/l)\nkw. trichlorooctowy TCAA (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","norm_bases":["GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie kwasów halogenooctowych (HAA)\nZakres:\nkw. monochlorooctowy MCAA\nZakres (5,0 – 100) ng/l\nkw. monobromooctowy MBAA (5,0 – 100 ng/l)\nkw. dichlorooctowy DCAA (5,0 – 100 ng/l)\nkw. dibromooctowy DBAA (5,0 – 100 ng/l)\nkw. trichlorooctowy TCAA (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024 Woda, woda do spozycia przez ludzi Stezenie kwasow halogenooctowych (HAA)\nZakres:\nkw. monochlorooctowy MCAA\nZakres (5,0 – 100) ng/l\nkw. monobromooctowy MBAA (5,0 – 100 ng/l)\nkw. dichlorooctowy DCAA (5,0 – 100 ng/l)\nkw. dibromooctowy DBAA (5,0 – 100 ng/l)\nkw. trichlorooctowy TCAA (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Haloacetic acid (HAA) concentration Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) monochloroacetic acid MCAA Range monobromoacetic acid MBAA dichloroacetic acid DCAA dibromoacetic acid DBAA trichloroacetic acid TCAA GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","parameters_zh":[{"name":"kw. monochlorooctowy MCAA"},{"name":"范围","range":"(5,0 – 100) ng/l"},{"name":"kw. monobromooctowy MBAA","range":"(5,0 – 100 ng/l)"},{"name":"kw. dichlorooctowy DCAA","range":"(5,0 – 100 ng/l)"},{"name":"kw. dibromooctowy DBAA","range":"(5,0 – 100 ng/l)"},{"name":"kw. trichlorooctowy TCAA","range":"(5,0 – 100 ng/l)"}],"search_zh":"水、生活饮用水 卤乙酸（HAA）浓度 液相色谱-串联质谱法（LC-MS-MS） 范围 GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","test_object_zh":"水、生活饮用水","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）","methodology_zh":"卤乙酸（HAA）浓度"},{"_id":"6a5e783f4cc76d93cba39ea8","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma HAA (z obliczeń)","methodology_en":"Sum of HAA (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma HAA (z obliczeń)","reference":"GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","norm_bases":["GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma HAA (z obliczeń) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024 Woda, woda do spozycia przez ludzi Suma HAA (z obliczen) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","categories":["water"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sum of HAA (calculated) GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","search_zh":"水、生活饮用水 GdW/SL/PB-74 wyd. 01 z dnia 06.05.2024","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ea9","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie Bisfenolu-A","methodology_en":"Bisphenol-A concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,5) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,5) μg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie Bisfenolu-A\nZakres (0,05 – 2,5) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025","norm_bases":["GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie Bisfenolu-A\nZakres (0,05 – 2,5) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025 Woda, woda do spozycia przez ludzi Stezenie Bisfenolu-A\nZakres (0,05 – 2,5) μg/l\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025","categories":["water"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Bisphenol-A concentration Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Range GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025","parameters_zh":[{"name":"范围","range":"(0,05 – 2,5) μg/l"}],"search_zh":"水、生活饮用水 液相色谱-串联质谱法（LC-MS-MS） 范围 GdW/SL/PB-77 wyd. 01 z dnia 10.07.2025","test_object_zh":"水、生活饮用水","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a5e783f4cc76d93cba39eaa","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie kwasów perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)","methodology_en":"Concentration of perfluoroalkyl and perfluoroalkyl sulfonic acids (PFAS)","parameters":[{"name":"kwas perfluorobutanowy (PFBA)"},{"name":"Zakres","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoropentanowy (PFPeA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheksanowy (PFHxA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheptanowy (PFHpA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorooktanowy (PFOA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorononanowy (PFNA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorodekanowy (PFDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroundekanowy (PFUnDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorododekanowy (PFDoDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorotridekanowy (PFTrDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorobutanosulfonowy (PFBS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoropentanosulfonowy (PSPS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheksanosulfonowy (PFHxS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheptanosulfonowy (PFHpS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorooktanosulfonowy (PFOS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorononanosulfonowy (PFNS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorodekanosulfonowy (PFDS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroundekanosulfonowy (PFUnDS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorododekanosulfonowy (PFDoDS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorotridekanosulfonowy (PFTrDS)","range":"(5,0 – 100 ng/l)"}],"parameters_en":[{"name":"perfluorobutanoic acid (PFBA)"},{"name":"Range","range":"(5,0 – 100 ng/l)"},{"name":"perfluoropentanoic acid (PFPeA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorohexanoic acid (PFHxA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroheptanoic acid (PFHpA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorooctanoic acid (PFOA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorononanoic acid (PFNA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorodecanoic acid (PFDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroundecanoic acid (PFUnDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorododecanoic acid (PFDoDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorotridecanoic acid (PFTrDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorobutanesulfonic acid (PFBS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoropentanesulfonic acid (PSPS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorohexanesulfonic acid (PFHxS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroheptanesulfonic acid (PFHpS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorooctanesulfonic acid (PFOS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorononanesulfonic acid (PFNS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorodecanesulfonic acid (PFDS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroundecanesulfonic acid (PFUnDS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorododecanesulfonic acid (PFDoDS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorotridecanesulfonic acid (PFTrDS)","range":"(5,0 – 100 ng/l)"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie kwasów perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (5,0 – 100 ng/l)\nkwas perfluoropentanowy (PFPeA) (5,0 – 100 ng/l)\nkwas perfluoroheksanowy (PFHxA) (5,0 – 100 ng/l)\nkwas perfluoroheptanowy (PFHpA) (5,0 – 100 ng/l)\nkwas perfluorooktanowy (PFOA) (5,0 – 100 ng/l)\nkwas perfluorononanowy (PFNA) (5,0 – 100 ng/l)\nkwas perfluorodekanowy (PFDA) (5,0 – 100 ng/l)\nkwas perfluoroundekanowy (PFUnDA) (5,0 – 100 ng/l)\nkwas perfluorododekanowy (PFDoDA) (5,0 – 100 ng/l)\nkwas perfluorotridekanowy (PFTrDA) (5,0 – 100 ng/l)\nkwas perfluorobutanosulfonowy (PFBS) (5,0 – 100 ng/l)\nkwas perfluoropentanosulfonowy (PSPS) (5,0 – 100 ng/l)\nkwas perfluoroheksanosulfonowy (PFHxS) (5,0 – 100 ng/l)\nkwas perfluoroheptanosulfonowy (PFHpS) (5,0 – 100 ng/l)\nkwas perfluorooktanosulfonowy (PFOS) (5,0 – 100 ng/l)\nkwas perfluorononanosulfonowy (PFNS) (5,0 – 100 ng/l)\nkwas perfluorodekanosulfonowy (PFDS) (5,0 – 100 ng/l)\nkwas perfluoroundekanosulfonowy (PFUnDS) (5,0 – 100 ng/l)\nkwas perfluorododekanosulfonowy (PFDoDS) (5,0 – 100 ng/l)\nkwas perfluorotridekanosulfonowy (PFTrDS) (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","norm_bases":["GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie kwasów perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (5,0 – 100 ng/l)\nkwas perfluoropentanowy (PFPeA) (5,0 – 100 ng/l)\nkwas perfluoroheksanowy (PFHxA) (5,0 – 100 ng/l)\nkwas perfluoroheptanowy (PFHpA) (5,0 – 100 ng/l)\nkwas perfluorooktanowy (PFOA) (5,0 – 100 ng/l)\nkwas perfluorononanowy (PFNA) (5,0 – 100 ng/l)\nkwas perfluorodekanowy (PFDA) (5,0 – 100 ng/l)\nkwas perfluoroundekanowy (PFUnDA) (5,0 – 100 ng/l)\nkwas perfluorododekanowy (PFDoDA) (5,0 – 100 ng/l)\nkwas perfluorotridekanowy (PFTrDA) (5,0 – 100 ng/l)\nkwas perfluorobutanosulfonowy (PFBS) (5,0 – 100 ng/l)\nkwas perfluoropentanosulfonowy (PSPS) (5,0 – 100 ng/l)\nkwas perfluoroheksanosulfonowy (PFHxS) (5,0 – 100 ng/l)\nkwas perfluoroheptanosulfonowy (PFHpS) (5,0 – 100 ng/l)\nkwas perfluorooktanosulfonowy (PFOS) (5,0 – 100 ng/l)\nkwas perfluorononanosulfonowy (PFNS) (5,0 – 100 ng/l)\nkwas perfluorodekanosulfonowy (PFDS) (5,0 – 100 ng/l)\nkwas perfluoroundekanosulfonowy (PFUnDS) (5,0 – 100 ng/l)\nkwas perfluorododekanosulfonowy (PFDoDS) (5,0 – 100 ng/l)\nkwas perfluorotridekanosulfonowy (PFTrDS) (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024 Woda, woda do spozycia przez ludzi Stezenie kwasow perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (5,0 – 100 ng/l)\nkwas perfluoropentanowy (PFPeA) (5,0 – 100 ng/l)\nkwas perfluoroheksanowy (PFHxA) (5,0 – 100 ng/l)\nkwas perfluoroheptanowy (PFHpA) (5,0 – 100 ng/l)\nkwas perfluorooktanowy (PFOA) (5,0 – 100 ng/l)\nkwas perfluorononanowy (PFNA) (5,0 – 100 ng/l)\nkwas perfluorodekanowy (PFDA) (5,0 – 100 ng/l)\nkwas perfluoroundekanowy (PFUnDA) (5,0 – 100 ng/l)\nkwas perfluorododekanowy (PFDoDA) (5,0 – 100 ng/l)\nkwas perfluorotridekanowy (PFTrDA) (5,0 – 100 ng/l)\nkwas perfluorobutanosulfonowy (PFBS) (5,0 – 100 ng/l)\nkwas perfluoropentanosulfonowy (PSPS) (5,0 – 100 ng/l)\nkwas perfluoroheksanosulfonowy (PFHxS) (5,0 – 100 ng/l)\nkwas perfluoroheptanosulfonowy (PFHpS) (5,0 – 100 ng/l)\nkwas perfluorooktanosulfonowy (PFOS) (5,0 – 100 ng/l)\nkwas perfluorononanosulfonowy (PFNS) (5,0 – 100 ng/l)\nkwas perfluorodekanosulfonowy (PFDS) (5,0 – 100 ng/l)\nkwas perfluoroundekanosulfonowy (PFUnDS) (5,0 – 100 ng/l)\nkwas perfluorododekanosulfonowy (PFDoDS) (5,0 – 100 ng/l)\nkwas perfluorotridekanosulfonowy (PFTrDS) (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of perfluoroalkyl and perfluoroalkyl sulfonic acids (PFAS) Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) perfluorobutanoic acid (PFBA) Range perfluoropentanoic acid (PFPeA) perfluorohexanoic acid (PFHxA) perfluoroheptanoic acid (PFHpA) perfluorooctanoic acid (PFOA) perfluorononanoic acid (PFNA) perfluorodecanoic acid (PFDA) perfluoroundecanoic acid (PFUnDA) perfluorododecanoic acid (PFDoDA) perfluorotridecanoic acid (PFTrDA) perfluorobutanesulfonic acid (PFBS) perfluoropentanesulfonic acid (PSPS) perfluorohexanesulfonic acid (PFHxS) perfluoroheptanesulfonic acid (PFHpS) perfluorooctanesulfonic acid (PFOS) perfluorononanesulfonic acid (PFNS) perfluorodecanesulfonic acid (PFDS) perfluoroundecanesulfonic acid (PFUnDS) perfluorododecanesulfonic acid (PFDoDS) perfluorotridecanesulfonic acid (PFTrDS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","parameters_zh":[{"name":"全氟丁酸（PFBA）"},{"name":"范围","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoropentanowy (PFPeA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheksanowy (PFHxA)","range":"(5,0 – 100 ng/l)"},{"name":"全氟庚酸（PFHpA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟辛酸（PFOA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟壬酸（PFNA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟癸酸（PFDA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十一酸（PFUnDA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十二酸（PFDoDA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十三酸（PFTrDA）","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorobutanosulfonowy (PFBS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoropentanosulfonowy (PSPS)","range":"(5,0 – 100 ng/l)"},{"name":"全氟己烷磺酸（PFHxS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟庚烷磺酸（PFHpS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟辛烷磺酸（PFOS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟壬烷磺酸（PFNS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟癸烷磺酸（PFDS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十一烷磺酸（PFUnDS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十二烷磺酸（PFDoDS）","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorotridekanosulfonowy (PFTrDS)","range":"(5,0 – 100 ng/l)"}],"search_zh":"水、生活饮用水 液相色谱-串联质谱法（LC-MS-MS） 全氟丁酸（PFBA） 范围 全氟庚酸（PFHpA） 全氟辛酸（PFOA） 全氟壬酸（PFNA） 全氟癸酸（PFDA） 全氟十一酸（PFUnDA） 全氟十二酸（PFDoDA） 全氟十三酸（PFTrDA） 全氟己烷磺酸（PFHxS） 全氟庚烷磺酸（PFHpS） 全氟辛烷磺酸（PFOS） 全氟壬烷磺酸（PFNS） 全氟癸烷磺酸（PFDS） 全氟十一烷磺酸（PFUnDS） 全氟十二烷磺酸（PFDoDS） GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","test_object_zh":"水、生活饮用水","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a5e783f4cc76d93cba39eab","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma PFAS (z obliczeń)","methodology_en":"Sum of PFAS (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma PFAS (z obliczeń)","reference":"GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","norm_bases":["GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma PFAS (z obliczeń) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024 Woda, woda do spozycia przez ludzi Suma PFAS (z obliczen) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sum of PFAS (calculated) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","search_zh":"水、生活饮用水 PFAS 总量（由计算得出） GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","test_object_zh":"水、生活饮用水","methodology_zh":"PFAS 总量（由计算得出）"},{"_id":"6a5e783f4cc76d93cba39eac","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"azotany","range":"(0,20 – 50,0) mg/l"}],"parameters_en":[{"name":"nitrates","range":"(0,20 – 50,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nazotany (0,20 – 50,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC 2012","norm_bases":["PN-EN ISO 10304-1:2009+AC 2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie anionów\nazotany (0,20 – 50,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC 2012 Woda na plywalniach Stezenie anionow\nazotany (0,20 – 50,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC 2012","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrates PN-EN ISO 10304-1:2009+AC 2012","methodology_zh":"阴离子浓度","search_zh":"游泳池水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 PN-EN ISO 10304-1:2009+AC 2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"游泳池水","parameters_zh":[{"name":"硝酸盐","range":"(0,20 – 50,0) mg/l"}]},{"_id":"6a5e783f4cc76d93cba39ead","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"chlorki","range":"(1,0 – 5000) mg/l"},{"name":"fluorki","range":"(0,020 – 10,0) mg/l"},{"name":"azotany","range":"(0,20 – 250) mg/l"},{"name":"azotyny","range":"(0,003 – 60,0) mg/l"},{"name":"o-fosforany","range":"(0,020 – 25,0) mg/l"},{"name":"siarczany","range":"(1,0 – 5000) mg/l"}],"parameters_en":[{"name":"chlorides","range":"(1,0 – 5000) mg/l"},{"name":"fluorides","range":"(0,020 – 10,0) mg/l"},{"name":"nitrates","range":"(0,20 – 250) mg/l"},{"name":"nitrites","range":"(0,003 – 60,0) mg/l"},{"name":"orthophosphates","range":"(0,020 – 25,0) mg/l"},{"name":"sulfates","range":"(1,0 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nchlorki (1,0 – 5000) mg/l\nfluorki (0,020 – 10,0) mg/l\nazotany (0,20 – 250) mg/l\nazotyny (0,003 – 60,0) mg/l\no-fosforany (0,020 – 25,0) mg/l\nsiarczany (1,0 – 5000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC 2012","norm_bases":["PN-EN ISO 10304-1:2009+AC 2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie anionów\nZakres:\nchlorki (1,0 – 5000) mg/l\nfluorki (0,020 – 10,0) mg/l\nazotany (0,20 – 250) mg/l\nazotyny (0,003 – 60,0) mg/l\no-fosforany (0,020 – 25,0) mg/l\nsiarczany (1,0 – 5000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC 2012 Scieki Stezenie anionow\nZakres:\nchlorki (1,0 – 5000) mg/l\nfluorki (0,020 – 10,0) mg/l\nazotany (0,20 – 250) mg/l\nazotyny (0,003 – 60,0) mg/l\no-fosforany (0,020 – 25,0) mg/l\nsiarczany (1,0 – 5000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC 2012","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides fluorides nitrates nitrites orthophosphates sulfates PN-EN ISO 10304-1:2009+AC 2012","methodology_zh":"阴离子浓度","search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硝酸盐 亚硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009+AC 2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"氯化物","range":"(1,0 – 5000) mg/l"},{"name":"氟化物","range":"(0,020 – 10,0) mg/l"},{"name":"硝酸盐","range":"(0,20 – 250) mg/l"},{"name":"亚硝酸盐","range":"(0,003 – 60,0) mg/l"},{"name":"o-fosforany","range":"(0,020 – 25,0) mg/l"},{"name":"硫酸盐","range":"(1,0 – 5000) mg/l"}]},{"_id":"6a5e783f4cc76d93cba39eae","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie kwasów perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)","methodology_en":"Concentration of perfluoroalkyl and perfluoroalkyl sulfonic acids (PFAS)","parameters":[{"name":"kwas perfluorobutanowy (PFBA)"},{"name":"Zakres","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheptanowy (PFHpA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorooktanowy (PFOA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorononanowy (PFNA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorodekanowy (PFDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroundekanowy (PFUnDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorododekanowy (PFDoDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorotridekanowy (PFTrDA)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoropentanosulfonowy (PSPS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheksanosulfonowy (PFHxS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroheptanosulfonowy (PFHpS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorooktanosulfonowy (PFOS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorononanosulfonowy (PFNS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorodekanosulfonowy (PFDS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoroundekanosulfonowy (PFUnDS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorododekanosulfonowy (PFDoDS)","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorotridekanosulfonowy (PFTrDS)","range":"(5,0 – 100 ng/l)"}],"parameters_en":[{"name":"perfluorobutanoic acid (PFBA)"},{"name":"Range","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroheptanoic acid (PFHpA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorooctanoic acid (PFOA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorononanoic acid (PFNA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorodecanoic acid (PFDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroundecanoic acid (PFUnDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorododecanoic acid (PFDoDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorotridecanoic acid (PFTrDA)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoropentanesulfonic acid (PSPS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorohexanesulfonic acid (PFHxS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroheptanesulfonic acid (PFHpS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorooctanesulfonic acid (PFOS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorononanesulfonic acid (PFNS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorodecanesulfonic acid (PFDS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluoroundecanesulfonic acid (PFUnDS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorododecanesulfonic acid (PFDoDS)","range":"(5,0 – 100 ng/l)"},{"name":"perfluorotridecanesulfonic acid (PFTrDS)","range":"(5,0 – 100 ng/l)"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie kwasów perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (5,0 – 100 ng/l)\nkwas perfluoroheptanowy (PFHpA) (5,0 – 100 ng/l)\nkwas perfluorooktanowy (PFOA) (5,0 – 100 ng/l)\nkwas perfluorononanowy (PFNA) (5,0 – 100 ng/l)\nkwas perfluorodekanowy (PFDA) (5,0 – 100 ng/l)\nkwas perfluoroundekanowy (PFUnDA) (5,0 – 100 ng/l)\nkwas perfluorododekanowy (PFDoDA) (5,0 – 100 ng/l)\nkwas perfluorotridekanowy (PFTrDA) (5,0 – 100 ng/l)\nkwas perfluoropentanosulfonowy (PSPS) (5,0 – 100 ng/l)\nkwas perfluoroheksanosulfonowy (PFHxS) (5,0 – 100 ng/l)\nkwas perfluoroheptanosulfonowy (PFHpS) (5,0 – 100 ng/l)\nkwas perfluorooktanosulfonowy (PFOS) (5,0 – 100 ng/l)\nkwas perfluorononanosulfonowy (PFNS) (5,0 – 100 ng/l)\nkwas perfluorodekanosulfonowy (PFDS) (5,0 – 100 ng/l)\nkwas perfluoroundekanosulfonowy (PFUnDS) (5,0 – 100 ng/l)\nkwas perfluorododekanosulfonowy (PFDoDS) (5,0 – 100 ng/l)\nkwas perfluorotridekanosulfonowy (PFTrDS) (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","norm_bases":["GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie kwasów perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (5,0 – 100 ng/l)\nkwas perfluoroheptanowy (PFHpA) (5,0 – 100 ng/l)\nkwas perfluorooktanowy (PFOA) (5,0 – 100 ng/l)\nkwas perfluorononanowy (PFNA) (5,0 – 100 ng/l)\nkwas perfluorodekanowy (PFDA) (5,0 – 100 ng/l)\nkwas perfluoroundekanowy (PFUnDA) (5,0 – 100 ng/l)\nkwas perfluorododekanowy (PFDoDA) (5,0 – 100 ng/l)\nkwas perfluorotridekanowy (PFTrDA) (5,0 – 100 ng/l)\nkwas perfluoropentanosulfonowy (PSPS) (5,0 – 100 ng/l)\nkwas perfluoroheksanosulfonowy (PFHxS) (5,0 – 100 ng/l)\nkwas perfluoroheptanosulfonowy (PFHpS) (5,0 – 100 ng/l)\nkwas perfluorooktanosulfonowy (PFOS) (5,0 – 100 ng/l)\nkwas perfluorononanosulfonowy (PFNS) (5,0 – 100 ng/l)\nkwas perfluorodekanosulfonowy (PFDS) (5,0 – 100 ng/l)\nkwas perfluoroundekanosulfonowy (PFUnDS) (5,0 – 100 ng/l)\nkwas perfluorododekanosulfonowy (PFDoDS) (5,0 – 100 ng/l)\nkwas perfluorotridekanosulfonowy (PFTrDS) (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024 Scieki Stezenie kwasow perfluoroalkilowych i perfluoroalkilosulfonowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (5,0 – 100 ng/l)\nkwas perfluoroheptanowy (PFHpA) (5,0 – 100 ng/l)\nkwas perfluorooktanowy (PFOA) (5,0 – 100 ng/l)\nkwas perfluorononanowy (PFNA) (5,0 – 100 ng/l)\nkwas perfluorodekanowy (PFDA) (5,0 – 100 ng/l)\nkwas perfluoroundekanowy (PFUnDA) (5,0 – 100 ng/l)\nkwas perfluorododekanowy (PFDoDA) (5,0 – 100 ng/l)\nkwas perfluorotridekanowy (PFTrDA) (5,0 – 100 ng/l)\nkwas perfluoropentanosulfonowy (PSPS) (5,0 – 100 ng/l)\nkwas perfluoroheksanosulfonowy (PFHxS) (5,0 – 100 ng/l)\nkwas perfluoroheptanosulfonowy (PFHpS) (5,0 – 100 ng/l)\nkwas perfluorooktanosulfonowy (PFOS) (5,0 – 100 ng/l)\nkwas perfluorononanosulfonowy (PFNS) (5,0 – 100 ng/l)\nkwas perfluorodekanosulfonowy (PFDS) (5,0 – 100 ng/l)\nkwas perfluoroundekanosulfonowy (PFUnDS) (5,0 – 100 ng/l)\nkwas perfluorododekanosulfonowy (PFDoDS) (5,0 – 100 ng/l)\nkwas perfluorotridekanosulfonowy (PFTrDS) (5,0 – 100 ng/l)\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of perfluoroalkyl and perfluoroalkyl sulfonic acids (PFAS) Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) perfluorobutanoic acid (PFBA) Range perfluoroheptanoic acid (PFHpA) perfluorooctanoic acid (PFOA) perfluorononanoic acid (PFNA) perfluorodecanoic acid (PFDA) perfluoroundecanoic acid (PFUnDA) perfluorododecanoic acid (PFDoDA) perfluorotridecanoic acid (PFTrDA) perfluoropentanesulfonic acid (PSPS) perfluorohexanesulfonic acid (PFHxS) perfluoroheptanesulfonic acid (PFHpS) perfluorooctanesulfonic acid (PFOS) perfluorononanesulfonic acid (PFNS) perfluorodecanesulfonic acid (PFDS) perfluoroundecanesulfonic acid (PFUnDS) perfluorododecanesulfonic acid (PFDoDS) perfluorotridecanesulfonic acid (PFTrDS) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","parameters_zh":[{"name":"全氟丁酸（PFBA）"},{"name":"范围","range":"(5,0 – 100 ng/l)"},{"name":"全氟庚酸（PFHpA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟辛酸（PFOA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟壬酸（PFNA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟癸酸（PFDA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十一酸（PFUnDA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十二酸（PFDoDA）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十三酸（PFTrDA）","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluoropentanosulfonowy (PSPS)","range":"(5,0 – 100 ng/l)"},{"name":"全氟己烷磺酸（PFHxS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟庚烷磺酸（PFHpS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟辛烷磺酸（PFOS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟壬烷磺酸（PFNS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟癸烷磺酸（PFDS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十一烷磺酸（PFUnDS）","range":"(5,0 – 100 ng/l)"},{"name":"全氟十二烷磺酸（PFDoDS）","range":"(5,0 – 100 ng/l)"},{"name":"kwas perfluorotridekanosulfonowy (PFTrDS)","range":"(5,0 – 100 ng/l)"}],"search_zh":"污水 液相色谱-串联质谱法（LC-MS-MS） 全氟丁酸（PFBA） 范围 全氟庚酸（PFHpA） 全氟辛酸（PFOA） 全氟壬酸（PFNA） 全氟癸酸（PFDA） 全氟十一酸（PFUnDA） 全氟十二酸（PFDoDA） 全氟十三酸（PFTrDA） 全氟己烷磺酸（PFHxS） 全氟庚烷磺酸（PFHpS） 全氟辛烷磺酸（PFOS） 全氟壬烷磺酸（PFNS） 全氟癸烷磺酸（PFDS） 全氟十一烷磺酸（PFUnDS） 全氟十二烷磺酸（PFDoDS） GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","test_object_zh":"污水","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a5e783f4cc76d93cba39eaf","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Suma PFAS (z obliczeń)","methodology_en":"Sum of PFAS (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma PFAS (z obliczeń)","reference":"GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","norm_bases":["GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Suma PFAS (z obliczeń) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024 Scieki Suma PFAS (z obliczen) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","categories":["water"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sum of PFAS (calculated) GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","search_zh":"污水 PFAS 总量（由计算得出） GdW/SL/PB-75 wyd. 01 z dnia 06.05.2024","test_object_zh":"污水","methodology_zh":"PFAS 总量（由计算得出）"},{"_id":"6a5e783f4cc76d93cba39eb0","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Water, water intended for human consumption, wastewater (including rainwater and snowmelt water)","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki (w tym wody opadowe i roztopowe) Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, woda do spozycia przez ludzi, scieki (w tym wody opadowe i roztopowe) Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater (including rainwater and snowmelt water) Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"矿物油指数 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","methodology_zh":"矿物油指数","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a5e783f4cc76d93cba39eb1","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych:","methodology_en":"Concentration of polycyclic aromatic hydrocarbons:","parameters":[{"name":"Benzo(b)fluoranten","range":"(10,0 – 1000) ng/l"},{"name":"Benzo(k)fluoranten","range":"(10,0 – 1000) ng/l"},{"name":"Benzo(a)piren","range":"(10,0 – 1000) ng/l"},{"name":"Dibenzo(a,h)antracen"},{"name":"Zakres","range":"(10,0 – 1000) ng/l"},{"name":"Benzo(g,h,i)perylen","range":"(10,0 – 1000) ng/l"},{"name":"Indeno","range":"(1,2,3-c,d)piren"},{"name":"(10,0 – 1000) ng/l"},{"name":"Fluoranten","range":"(10,0 – 1000) ng/l"},{"name":"Chryzen","range":"(10,0 – 1000) ng/l"}],"parameters_en":[{"name":"Benzo(b)fluoranthene","range":"(10,0 – 1000) ng/l"},{"name":"Benzo(k)fluoranthene","range":"(10,0 – 1000) ng/l"},{"name":"Benzo(a)pyrene","range":"(10,0 – 1000) ng/l"},{"name":"Dibenzo(a,h)anthracene"},{"name":"Range","range":"(10,0 – 1000) ng/l"},{"name":"Benzo(g,h,i)perylene","range":"(10,0 – 1000) ng/l"},{"name":"Indeno","range":"(1,2,3-c,d)piren"},{"name":"(10,0 – 1000) ng/l"},{"name":"Fluoranthene","range":"(10,0 – 1000) ng/l"},{"name":"Chrysene","range":"(10,0 – 1000) ng/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych:\nZakres:\nBenzo(b)fluoranten (10,0 – 1000) ng/l\nBenzo(k)fluoranten (10,0 – 1000) ng/l\nBenzo(a)piren (10,0 – 1000) ng/l\nDibenzo(a,h)antracen\nZakres (10,0 – 1000) ng/l\nBenzo(g,h,i)perylen (10,0 – 1000) ng/l\nIndeno (1,2,3-c,d)piren\n(10,0 – 1000) ng/l\nFluoranten (10,0 – 1000) ng/l\nChryzen (10,0 – 1000) ng/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"GdW/SL/PB-15wyd.06 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-15wyd.06 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych:\nZakres:\nBenzo(b)fluoranten (10,0 – 1000) ng/l\nBenzo(k)fluoranten (10,0 – 1000) ng/l\nBenzo(a)piren (10,0 – 1000) ng/l\nDibenzo(a,h)antracen\nZakres (10,0 – 1000) ng/l\nBenzo(g,h,i)perylen (10,0 – 1000) ng/l\nIndeno (1,2,3-c,d)piren\n(10,0 – 1000) ng/l\nFluoranten (10,0 – 1000) ng/l\nChryzen (10,0 – 1000) ng/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) GdW/SL/PB-15wyd.06 z dnia 01.09.2023 Woda, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych:\nZakres:\nBenzo(b)fluoranten (10,0 – 1000) ng/l\nBenzo(k)fluoranten (10,0 – 1000) ng/l\nBenzo(a)piren (10,0 – 1000) ng/l\nDibenzo(a,h)antracen\nZakres (10,0 – 1000) ng/l\nBenzo(g,h,i)perylen (10,0 – 1000) ng/l\nIndeno (1,2,3-c,d)piren\n(10,0 – 1000) ng/l\nFluoranten (10,0 – 1000) ng/l\nChryzen (10,0 – 1000) ng/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) GdW/SL/PB-15wyd.06 z dnia 01.09.2023","categories":["water"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of polycyclic aromatic hydrocarbons: High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Dibenzo(a,h)anthracene Range Benzo(g,h,i)perylene Indeno (10,0 – 1000) ng/l Fluoranthene Chrysene GdW/SL/PB-15wyd.06 z dnia 01.09.2023","parameters_zh":[{"name":"苯并(b)荧蒽","range":"(10,0 – 1000) ng/l"},{"name":"苯并(k)荧蒽","range":"(10,0 – 1000) ng/l"},{"name":"苯并(a)芘","range":"(10,0 – 1000) ng/l"},{"name":"二苯并(a,h)蒽"},{"name":"范围","range":"(10,0 – 1000) ng/l"},{"name":"苯并(g,h,i)苝","range":"(10,0 – 1000) ng/l"},{"name":"茚并","range":"(1,2,3-c,d)piren"},{"name":"(10,0 – 1000) ng/l"},{"name":"荧蒽","range":"(10,0 – 1000) ng/l"},{"name":"䓛","range":"(10,0 – 1000) ng/l"}],"search_zh":"水、废水 高效液相色谱-荧光检测法（HPLC-FLD） 苯并(b)荧蒽 苯并(k)荧蒽 苯并(a)芘 二苯并(a,h)蒽 范围 苯并(g,h,i)苝 茚并 荧蒽 䓛 GdW/SL/PB-15wyd.06 z dnia 01.09.2023","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、废水"},{"_id":"6a5e783f4cc76d93cba39eb2","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma WWA (z obliczeń)","methodology_en":"Sum of PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma WWA (z obliczeń)","reference":"GdW/SL/PB-15wyd.06 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-15wyd.06 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma WWA (z obliczeń) GdW/SL/PB-15wyd.06 z dnia 01.09.2023 Woda, scieki Suma WWA (z obliczen) GdW/SL/PB-15wyd.06 z dnia 01.09.2023","categories":["water"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of PAH (calculated) GdW/SL/PB-15wyd.06 z dnia 01.09.2023","search_zh":"水、废水 多环芳烃总量（计算值） GdW/SL/PB-15wyd.06 z dnia 01.09.2023","test_object_zh":"水、废水","methodology_zh":"多环芳烃总量（计算值）"},{"_id":"6a5e783f4cc76d93cba39eb3","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorowanych związków organicznych","methodology_en":"Concentration of chlorinated organic compounds","parameters":[{"name":"heksachlorobenzen"},{"name":"Zakres","range":"(5,0 – 100) ng/l"},{"name":"lindan (gamma HCH)","range":"(5,0 – 100) ng/l"},{"name":"aldryna","range":"(5,0 – 100) ng/l"},{"name":"dieldryna","range":"(5,0 – 100) ng/l"},{"name":"endryna","range":"(5,0 – 100) ng/l"},{"name":"alfa- Endosulfan","range":"(5,0 – 100) ng/l"},{"name":"beta-Endosulfan","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DDT","range":"(5,0 – 100) ng/l"},{"name":"alfa-HCH","range":"(5,0 – 100) ng/l"},{"name":"beta-HCH","range":"(5,0 – 100) ng/l"},{"name":"delta-HCH","range":"(5,0 – 100) ng/l"},{"name":"Heptachlor","range":"(5,0 – 100) ng/l"},{"name":"Izodryna","range":"(5,0 – 100) ng/l"},{"name":"Epoksyd heptachloru","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DDE","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DDD","range":"(5,0 – 100) ng/l"},{"name":"Aldehyd endryny","range":"(5,0 – 100) ng/l"},{"name":"Siarczan endosulfanu","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DMDT - (metoksychlor)","range":"(5,0 – 100) ng/l"},{"name":"pentachlorobenzen","range":"(5,0 – 100) ng/l"},{"name":"trifluralin","range":"(5,0 – 100) ng/l"},{"name":"pendimetalin","range":"(5,0 – 100) ng/l"},{"name":"1,2,4-trichlorobenzen","range":"(10,0 – 100) ng/l"},{"name":"1,2,3- trichlorobenzen","range":"(10,0 – 100) ng/l"},{"name":"1,3,5 - trichlorobenzen","range":"(10,0 – 100) ng/l"}],"parameters_en":[{"name":"hexachlorobenzene"},{"name":"Range","range":"(5,0 – 100) ng/l"},{"name":"lindane (gamma HCH)","range":"(5,0 – 100) ng/l"},{"name":"aldrin","range":"(5,0 – 100) ng/l"},{"name":"dieldrin","range":"(5,0 – 100) ng/l"},{"name":"endrin","range":"(5,0 – 100) ng/l"},{"name":"alpha- Endosulfan","range":"(5,0 – 100) ng/l"},{"name":"beta-Endosulfan","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DDT","range":"(5,0 – 100) ng/l"},{"name":"alpha-HCH","range":"(5,0 – 100) ng/l"},{"name":"beta-HCH","range":"(5,0 – 100) ng/l"},{"name":"delta-HCH","range":"(5,0 – 100) ng/l"},{"name":"Heptachlor","range":"(5,0 – 100) ng/l"},{"name":"Isodrin","range":"(5,0 – 100) ng/l"},{"name":"Heptachlor epoxide","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DDE","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DDD","range":"(5,0 – 100) ng/l"},{"name":"Endrin aldehyde","range":"(5,0 – 100) ng/l"},{"name":"Endosulfan sulfate","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DMDT - (methoxychlor)","range":"(5,0 – 100) ng/l"},{"name":"pentachlorobenzene","range":"(5,0 – 100) ng/l"},{"name":"trifluralin","range":"(5,0 – 100) ng/l"},{"name":"pendimethalin","range":"(5,0 – 100) ng/l"},{"name":"1,2,4-trichlorobenzene","range":"(10,0 – 100) ng/l"},{"name":"1,2,3- trichlorobenzene","range":"(10,0 – 100) ng/l"},{"name":"1,3,5 - trichlorobenzene","range":"(10,0 – 100) ng/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie chlorowanych związków organicznych\nZakres:\nheksachlorobenzen\nZakres (5,0 – 100) ng/l\nlindan (gamma HCH) (5,0 – 100) ng/l\naldryna (5,0 – 100) ng/l\ndieldryna (5,0 – 100) ng/l\nendryna (5,0 – 100) ng/l\nalfa- Endosulfan (5,0 – 100) ng/l\nbeta-Endosulfan (5,0 – 100) ng/l\np,p’-DDT (5,0 – 100) ng/l\nalfa-HCH (5,0 – 100) ng/l\nbeta-HCH (5,0 – 100) ng/l\ndelta-HCH (5,0 – 100) ng/l\nHeptachlor (5,0 – 100) ng/l\nIzodryna (5,0 – 100) ng/l\nEpoksyd heptachloru (5,0 – 100) ng/l\np,p’-DDE (5,0 – 100) ng/l\np,p’-DDD (5,0 – 100) ng/l\nAldehyd endryny (5,0 – 100) ng/l\nSiarczan endosulfanu (5,0 – 100) ng/l\np,p’-DMDT - (metoksychlor) (5,0 – 100) ng/l\npentachlorobenzen (5,0 – 100) ng/l\ntrifluralin (5,0 – 100) ng/l\npendimetalin (5,0 – 100) ng/l\n1,2,4-trichlorobenzen (10,0 – 100) ng/l\n1,2,3- trichlorobenzen (10,0 – 100) ng/l\n1,3,5 - trichlorobenzen (10,0 – 100) ng/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorowanych związków organicznych\nZakres:\nheksachlorobenzen\nZakres (5,0 – 100) ng/l\nlindan (gamma HCH) (5,0 – 100) ng/l\naldryna (5,0 – 100) ng/l\ndieldryna (5,0 – 100) ng/l\nendryna (5,0 – 100) ng/l\nalfa- Endosulfan (5,0 – 100) ng/l\nbeta-Endosulfan (5,0 – 100) ng/l\np,p’-DDT (5,0 – 100) ng/l\nalfa-HCH (5,0 – 100) ng/l\nbeta-HCH (5,0 – 100) ng/l\ndelta-HCH (5,0 – 100) ng/l\nHeptachlor (5,0 – 100) ng/l\nIzodryna (5,0 – 100) ng/l\nEpoksyd heptachloru (5,0 – 100) ng/l\np,p’-DDE (5,0 – 100) ng/l\np,p’-DDD (5,0 – 100) ng/l\nAldehyd endryny (5,0 – 100) ng/l\nSiarczan endosulfanu (5,0 – 100) ng/l\np,p’-DMDT - (metoksychlor) (5,0 – 100) ng/l\npentachlorobenzen (5,0 – 100) ng/l\ntrifluralin (5,0 – 100) ng/l\npendimetalin (5,0 – 100) ng/l\n1,2,4-trichlorobenzen (10,0 – 100) ng/l\n1,2,3- trichlorobenzen (10,0 – 100) ng/l\n1,3,5 - trichlorobenzen (10,0 – 100) ng/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Stezenie chlorowanych zwiazkow organicznych\nZakres:\nheksachlorobenzen\nZakres (5,0 – 100) ng/l\nlindan (gamma HCH) (5,0 – 100) ng/l\naldryna (5,0 – 100) ng/l\ndieldryna (5,0 – 100) ng/l\nendryna (5,0 – 100) ng/l\nalfa- Endosulfan (5,0 – 100) ng/l\nbeta-Endosulfan (5,0 – 100) ng/l\np,p’-DDT (5,0 – 100) ng/l\nalfa-HCH (5,0 – 100) ng/l\nbeta-HCH (5,0 – 100) ng/l\ndelta-HCH (5,0 – 100) ng/l\nHeptachlor (5,0 – 100) ng/l\nIzodryna (5,0 – 100) ng/l\nEpoksyd heptachloru (5,0 – 100) ng/l\np,p’-DDE (5,0 – 100) ng/l\np,p’-DDD (5,0 – 100) ng/l\nAldehyd endryny (5,0 – 100) ng/l\nSiarczan endosulfanu (5,0 – 100) ng/l\np,p’-DMDT - (metoksychlor) (5,0 – 100) ng/l\npentachlorobenzen (5,0 – 100) ng/l\ntrifluralin (5,0 – 100) ng/l\npendimetalin (5,0 – 100) ng/l\n1,2,4-trichlorobenzen (10,0 – 100) ng/l\n1,2,3- trichlorobenzen (10,0 – 100) ng/l\n1,3,5 - trichlorobenzen (10,0 – 100) ng/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","categories":["water"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of chlorinated organic compounds Gas chromatography with electron capture detection (GC-ECD) hexachlorobenzene Range lindane (gamma HCH) aldrin dieldrin endrin alpha- Endosulfan beta-Endosulfan p,p’-DDT alpha-HCH beta-HCH delta-HCH Heptachlor Isodrin Heptachlor epoxide p,p’-DDE p,p’-DDD Endrin aldehyde Endosulfan sulfate p,p’-DMDT - (methoxychlor) pentachlorobenzene trifluralin pendimethalin 1,2,4-trichlorobenzene 1,2,3- trichlorobenzene 1,3,5 - trichlorobenzene GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","parameters_zh":[{"name":"六氯苯"},{"name":"范围","range":"(5,0 – 100) ng/l"},{"name":"lindan (gamma HCH)","range":"(5,0 – 100) ng/l"},{"name":"艾氏剂","range":"(5,0 – 100) ng/l"},{"name":"狄氏剂","range":"(5,0 – 100) ng/l"},{"name":"异狄氏剂","range":"(5,0 – 100) ng/l"},{"name":"alfa- Endosulfan","range":"(5,0 – 100) ng/l"},{"name":"beta-Endosulfan","range":"(5,0 – 100) ng/l"},{"name":"p,p'-滴滴涕（DDT）","range":"(5,0 – 100) ng/l"},{"name":"α-六六六","range":"(5,0 – 100) ng/l"},{"name":"β-六六六","range":"(5,0 – 100) ng/l"},{"name":"δ-六六六","range":"(5,0 – 100) ng/l"},{"name":"七氯","range":"(5,0 – 100) ng/l"},{"name":"异艾氏剂","range":"(5,0 – 100) ng/l"},{"name":"环氧七氯","range":"(5,0 – 100) ng/l"},{"name":"p,p'-滴滴伊（DDE）","range":"(5,0 – 100) ng/l"},{"name":"p,p'-滴滴滴（DDD）","range":"(5,0 – 100) ng/l"},{"name":"异狄氏剂醛","range":"(5,0 – 100) ng/l"},{"name":"硫酸盐硫丹","range":"(5,0 – 100) ng/l"},{"name":"p,p’-DMDT - (metoksychlor)","range":"(5,0 – 100) ng/l"},{"name":"五氯苯","range":"(5,0 – 100) ng/l"},{"name":"trifluralin","range":"(5,0 – 100) ng/l"},{"name":"pendimetalin","range":"(5,0 – 100) ng/l"},{"name":"1,2,4-三氯苯","range":"(10,0 – 100) ng/l"},{"name":"1,2,3- trichlorobenzen","range":"(10,0 – 100) ng/l"},{"name":"1,3,5 - trichlorobenzen","range":"(10,0 – 100) ng/l"}],"search_zh":"水、生活饮用水 气相色谱-电子捕获检测法（GC-ECD） 六氯苯 范围 艾氏剂 狄氏剂 异狄氏剂 p,p'-滴滴涕（DDT） α-六六六 β-六六六 δ-六六六 七氯 异艾氏剂 环氧七氯 p,p'-滴滴伊（DDE） p,p'-滴滴滴（DDD） 异狄氏剂醛 硫酸盐硫丹 五氯苯 1,2,4-三氯苯 GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39eb4","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie sumy pestycydów (z obliczeń)","methodology_en":"Concentration of total pesticides (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie sumy pestycydów (z obliczeń)","reference":"GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie sumy pestycydów (z obliczeń) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Stezenie sumy pestycydow (z obliczen) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","categories":["water"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of total pesticides (calculated) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","search_zh":"水、生活饮用水 GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39eb5","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie Trichlorobenzenu (suma izomerów) (z obliczeń)","methodology_en":"Trichlorobenzene concentration (sum of isomers) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie Trichlorobenzenu (suma izomerów) (z obliczeń)","reference":"GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie Trichlorobenzenu (suma izomerów) (z obliczeń) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023 Woda, woda do spozycia przez ludzi Stezenie Trichlorobenzenu (suma izomerow) (z obliczen) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Trichlorobenzene concentration (sum of isomers) (calculated) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","search_zh":"水、生活饮用水 GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39eb6","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie","methodology_en":"Concentration","parameters":[{"name":"trans-1,2-dichloroeten"},{"name":"Zakres","range":"(0,1 – 50,0) μg/l"},{"name":"cis-1,2-dichloroeten","range":"(0,1 – 50,0) μg/l"},{"name":"1,2-dichlorobenzen","range":"(0,1 – 50,0) μg/l"},{"name":"1,3-dichlorobenzen","range":"(0,1 – 50,0) μg/l"},{"name":"1,4-dichlorobenzen","range":"(0,1 – 50,0) μg/l"},{"name":"chlorobenzen","range":"(0,1 – 50,0) μg/l"}],"parameters_en":[{"name":"trans-1,2-dichloroethene"},{"name":"Range","range":"(0,1 – 50,0) μg/l"},{"name":"cis-1,2-dichloroethene","range":"(0,1 – 50,0) μg/l"},{"name":"1,2-dichlorobenzene","range":"(0,1 – 50,0) μg/l"},{"name":"1,3-dichlorobenzene","range":"(0,1 – 50,0) μg/l"},{"name":"1,4-dichlorobenzene","range":"(0,1 – 50,0) μg/l"},{"name":"chlorobenzene","range":"(0,1 – 50,0) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie\nZakres:\ntrans-1,2-dichloroeten\nZakres (0,1 – 50,0) μg/l\ncis-1,2-dichloroeten (0,1 – 50,0) μg/l\n1,2-dichlorobenzen (0,1 – 50,0) μg/l\n1,3-dichlorobenzen (0,1 – 50,0) μg/l\n1,4-dichlorobenzen (0,1 – 50,0) μg/l\nchlorobenzen (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie\nZakres:\ntrans-1,2-dichloroeten\nZakres (0,1 – 50,0) μg/l\ncis-1,2-dichloroeten (0,1 – 50,0) μg/l\n1,2-dichlorobenzen (0,1 – 50,0) μg/l\n1,3-dichlorobenzen (0,1 – 50,0) μg/l\n1,4-dichlorobenzen (0,1 – 50,0) μg/l\nchlorobenzen (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda, woda do spozycia przez ludzi Stezenie\nZakres:\ntrans-1,2-dichloroeten\nZakres (0,1 – 50,0) μg/l\ncis-1,2-dichloroeten (0,1 – 50,0) μg/l\n1,2-dichlorobenzen (0,1 – 50,0) μg/l\n1,3-dichlorobenzen (0,1 – 50,0) μg/l\n1,4-dichlorobenzen (0,1 – 50,0) μg/l\nchlorobenzen (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) trans-1,2-dichloroethene Range cis-1,2-dichloroethene 1,2-dichlorobenzene 1,3-dichlorobenzene 1,4-dichlorobenzene chlorobenzene PN-EN ISO 15680:2008","parameters_zh":[{"name":"反式-1,2-二氯乙烯"},{"name":"范围","range":"(0,1 – 50,0) μg/l"},{"name":"顺式-1,2-二氯乙烯","range":"(0,1 – 50,0) μg/l"},{"name":"1,2-二氯苯","range":"(0,1 – 50,0) μg/l"},{"name":"1,3-二氯苯","range":"(0,1 – 50,0) μg/l"},{"name":"1,4-二氯苯","range":"(0,1 – 50,0) μg/l"},{"name":"氯苯","range":"(0,1 – 50,0) μg/l"}],"search_zh":"水、生活饮用水 浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 反式-1,2-二氯乙烯 范围 顺式-1,2-二氯乙烯 1,2-二氯苯 1,3-二氯苯 1,4-二氯苯 氯苯 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","methodology_zh":"浓度","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a5e783f4cc76d93cba39eb7","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie polichlorowanych bifenyli (PCB)","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters":[{"name":"PCB-28","range":"(5,0 – 100) ng/l"},{"name":"PCB-52","range":"(5,0 – 100) ng/l"},{"name":"PCB-101","range":"(5,0 – 100) ng/l"},{"name":"PCB-118","range":"(5,0 – 100) ng/l"},{"name":"PCB-138","range":"(5,0 – 100) ng/l"},{"name":"PCB-153","range":"(5,0 – 100) ng/l"},{"name":"PCB-180","range":"(5,0 – 100)) ng/l"}],"parameters_en":[{"name":"PCB-28","range":"(5,0 – 100) ng/l"},{"name":"PCB-52","range":"(5,0 – 100) ng/l"},{"name":"PCB-101","range":"(5,0 – 100) ng/l"},{"name":"PCB-118","range":"(5,0 – 100) ng/l"},{"name":"PCB-138","range":"(5,0 – 100) ng/l"},{"name":"PCB-153","range":"(5,0 – 100) ng/l"},{"name":"PCB-180","range":"(5,0 – 100)) ng/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB-28 (5,0 – 100) ng/l\nPCB-52 (5,0 – 100) ng/l\nPCB-101 (5,0 – 100) ng/l\nPCB-118 (5,0 – 100) ng/l\nPCB-138 (5,0 – 100) ng/l\nPCB-153 (5,0 – 100) ng/l\nPCB-180 (5,0 – 100)) ng/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB-28 (5,0 – 100) ng/l\nPCB-52 (5,0 – 100) ng/l\nPCB-101 (5,0 – 100) ng/l\nPCB-118 (5,0 – 100) ng/l\nPCB-138 (5,0 – 100) ng/l\nPCB-153 (5,0 – 100) ng/l\nPCB-180 (5,0 – 100)) ng/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023 Woda Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB-28 (5,0 – 100) ng/l\nPCB-52 (5,0 – 100) ng/l\nPCB-101 (5,0 – 100) ng/l\nPCB-118 (5,0 – 100) ng/l\nPCB-138 (5,0 – 100) ng/l\nPCB-153 (5,0 – 100) ng/l\nPCB-180 (5,0 – 100)) ng/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Polychlorinated biphenyls (PCB) concentration Gas chromatography with electron capture detection (GC-ECD) PCB-28 PCB-52 PCB-101 PCB-118 PCB-138 PCB-153 PCB-180 GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","search_zh":"水 多氯联苯（PCB）浓度 气相色谱-电子捕获检测法（GC-ECD） GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水","methodology_zh":"多氯联苯（PCB）浓度"},{"_id":"6a5e783f4cc76d93cba39eb8","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie sumy PCB (z obliczeń)","methodology_en":"Concentration of total PCB (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie sumy PCB (z obliczeń)","reference":"GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","norm_bases":["GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie sumy PCB (z obliczeń) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023 Woda Stezenie sumy PCB (z obliczen) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","categories":["water"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of total PCB (calculated) GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","search_zh":"水 GdW/SL/PB-19 wyd. 14 z dnia 01.09.2023","test_object_zh":"水"},{"_id":"6a5e783f4cc76d93cba39eb9","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi, ścieki","test_object_en":"Water (including swimming pool water), water intended for human consumption, wastewater","methodology":"Stężenie jednopierścieniowych węglowodorów aromatycznych oraz lotnych związków chloroorganicznych","methodology_en":"Concentration of monocyclic aromatic hydrocarbons and volatile organochlorine compounds","parameters":[{"name":"chloroform ( trichlorometan)"},{"name":"Zakres","range":"(0,5 – 100,0) μg/l"},{"name":"bromodichlorometan","range":"(0,1 – 100,0) μg/l"},{"name":"dibromochlorometan","range":"(0,1 – 100,0) μg/l"},{"name":"bromoform (tribromometan)","range":"(0,1 – 100,0) μg/l"}],"parameters_en":[{"name":"chloroform ( trichloromethane)"},{"name":"Range","range":"(0,5 – 100,0) μg/l"},{"name":"bromodichloromethane","range":"(0,1 – 100,0) μg/l"},{"name":"dibromochloromethane","range":"(0,1 – 100,0) μg/l"},{"name":"bromoform (tribromomethane)","range":"(0,1 – 100,0) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie jednopierścieniowych węglowodorów aromatycznych oraz lotnych związków chloroorganicznych\nZakres:\nchloroform ( trichlorometan)\nZakres (0,5 – 100,0) μg/l\nbromodichlorometan (0,1 – 100,0) μg/l\ndibromochlorometan (0,1 – 100,0) μg/l\nbromoform (tribromometan) (0,1 – 100,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi, ścieki Stężenie jednopierścieniowych węglowodorów aromatycznych oraz lotnych związków chloroorganicznych\nZakres:\nchloroform ( trichlorometan)\nZakres (0,5 – 100,0) μg/l\nbromodichlorometan (0,1 – 100,0) μg/l\ndibromochlorometan (0,1 – 100,0) μg/l\nbromoform (tribromometan) (0,1 – 100,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS) PN-EN ISO 15680:2008 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi, scieki Stezenie jednopierscieniowych weglowodorow aromatycznych oraz lotnych zwiazkow chloroorganicznych\nZakres:\nchloroform ( trichlorometan)\nZakres (0,5 – 100,0) μg/l\nbromodichlorometan (0,1 – 100,0) μg/l\ndibromochlorometan (0,1 – 100,0) μg/l\nbromoform (tribromometan) (0,1 – 100,0) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption, wastewater Concentration of monocyclic aromatic hydrocarbons and volatile organochlorine compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS) chloroform ( trichloromethane) Range bromodichloromethane dibromochloromethane bromoform (tribromomethane) PN-EN ISO 15680:2008","parameters_zh":[{"name":"chloroform ( trichlorometan)"},{"name":"范围","range":"(0,5 – 100,0) μg/l"},{"name":"一溴二氯甲烷","range":"(0,1 – 100,0) μg/l"},{"name":"二溴一氯甲烷","range":"(0,1 – 100,0) μg/l"},{"name":"bromoform (tribromometan)","range":"(0,1 – 100,0) μg/l"}],"search_zh":"水（含游泳池水）、生活饮用水、废水 范围 一溴二氯甲烷 二溴一氯甲烷 PN-EN ISO 15680:2008","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a5e783f4cc76d93cba39eba","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi, ścieki","test_object_en":"Water (including swimming pool water), water intended for human consumption, wastewater","methodology":"Stężenie sumy THM (chloroform, bromodichlormetan, dibromochlorometan, bromoform) (z obliczeń)","methodology_en":"Concentration of total THM (chloroform, bromodichloromethane, dibromochloromethane, bromoform) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie sumy THM (chloroform, bromodichlormetan, dibromochlorometan, bromoform) (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi, ścieki Stężenie sumy THM (chloroform, bromodichlormetan, dibromochlorometan, bromoform) (z obliczeń) PN-EN ISO 15680:2008 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi, scieki Stezenie sumy THM (chloroform, bromodichlormetan, dibromochlorometan, bromoform) (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption, wastewater Concentration of total THM (chloroform, bromodichloromethane, dibromochloromethane, bromoform) (calculated) PN-EN ISO 15680:2008","search_zh":"水（含游泳池水）、生活饮用水、废水 PN-EN ISO 15680:2008","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a5e783f4cc76d93cba39ebb","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie jednopierścieniowych węglowodorów aromatycznych oraz lotnych związków chloroorganicznych","methodology_en":"Concentration of monocyclic aromatic hydrocarbons and volatile organochlorine compounds","parameters":[{"name":"chloroform ( trichlorometan)"},{"name":"Zakres","range":"(0,5 – 50,0) μg/l"},{"name":"bromodichlorometan","range":"(0,1 – 50,0) μg/l"},{"name":"dibromochlorometan","range":"(0,1 – 50,0) μg/l"},{"name":"bromoform (tribromometan)","range":"(0,1 – 50,0) μg/l"}],"parameters_en":[{"name":"chloroform ( trichloromethane)"},{"name":"Range","range":"(0,5 – 50,0) μg/l"},{"name":"bromodichloromethane","range":"(0,1 – 50,0) μg/l"},{"name":"dibromochloromethane","range":"(0,1 – 50,0) μg/l"},{"name":"bromoform (tribromomethane)","range":"(0,1 – 50,0) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie jednopierścieniowych węglowodorów aromatycznych oraz lotnych związków chloroorganicznych\nZakres:\nchloroform ( trichlorometan)\nZakres (0,5 – 50,0) μg/l\nbromodichlorometan (0,1 – 50,0) μg/l\ndibromochlorometan (0,1 – 50,0) μg/l\nbromoform (tribromometan) (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie jednopierścieniowych węglowodorów aromatycznych oraz lotnych związków chloroorganicznych\nZakres:\nchloroform ( trichlorometan)\nZakres (0,5 – 50,0) μg/l\nbromodichlorometan (0,1 – 50,0) μg/l\ndibromochlorometan (0,1 – 50,0) μg/l\nbromoform (tribromometan) (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (GC-MS) PN-EN ISO 15680:2008 Scieki Stezenie jednopierscieniowych weglowodorow aromatycznych oraz lotnych zwiazkow chloroorganicznych\nZakres:\nchloroform ( trichlorometan)\nZakres (0,5 – 50,0) μg/l\nbromodichlorometan (0,1 – 50,0) μg/l\ndibromochlorometan (0,1 – 50,0) μg/l\nbromoform (tribromometan) (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of monocyclic aromatic hydrocarbons and volatile organochlorine compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS) chloroform ( trichloromethane) Range bromodichloromethane dibromochloromethane bromoform (tribromomethane) PN-EN ISO 15680:2008","parameters_zh":[{"name":"chloroform ( trichlorometan)"},{"name":"范围","range":"(0,5 – 50,0) μg/l"},{"name":"一溴二氯甲烷","range":"(0,1 – 50,0) μg/l"},{"name":"二溴一氯甲烷","range":"(0,1 – 50,0) μg/l"},{"name":"bromoform (tribromometan)","range":"(0,1 – 50,0) μg/l"}],"search_zh":"污水 范围 一溴二氯甲烷 二溴一氯甲烷 PN-EN ISO 15680:2008","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39ebc","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie","methodology_en":"Concentration","parameters":[{"name":"czterochlorek węgla","range":"(0,05 – 5,00) μg/l"},{"name":"trichloroeten","range":"(0,1 – 50,0) μg/l"},{"name":"tetrachloroeten","range":"(0,1 – 50,0) μg/l"}],"parameters_en":[{"name":"carbon tetrachloride","range":"(0,05 – 5,00) μg/l"},{"name":"trichloroethene","range":"(0,1 – 50,0) μg/l"},{"name":"tetrachloroethene","range":"(0,1 – 50,0) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie\nZakres:\nczterochlorek węgla (0,05 – 5,00) μg/l\ntrichloroeten (0,1 – 50,0) μg/l\ntetrachloroeten (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie\nZakres:\nczterochlorek węgla (0,05 – 5,00) μg/l\ntrichloroeten (0,1 – 50,0) μg/l\ntetrachloroeten (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda, woda do spozycia przez ludzi, scieki Stezenie\nZakres:\nczterochlorek wegla (0,05 – 5,00) μg/l\ntrichloroeten (0,1 – 50,0) μg/l\ntetrachloroeten (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Concentration Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) carbon tetrachloride trichloroethene tetrachloroethene PN-EN ISO 15680:2008","search_zh":"水、生活饮用水、污水 浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 三氯乙烯 四氯乙烯 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水、污水","parameters_zh":[{"name":"czterochlorek węgla","range":"(0,05 – 5,00) μg/l"},{"name":"三氯乙烯","range":"(0,1 – 50,0) μg/l"},{"name":"四氯乙烯","range":"(0,1 – 50,0) μg/l"}],"methodology_zh":"浓度","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a5e783f4cc76d93cba39ebd","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie sumy trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Concentration of the sum of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie sumy trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie sumy trichloroetenu i tetrachloroetenu (z obliczeń) PN-EN ISO 15680:2008 Woda, woda do spozycia przez ludzi, scieki Stezenie sumy trichloroetenu i tetrachloroetenu (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Concentration of the sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水、污水 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5e783f4cc76d93cba39ebe","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie jednopierścieniowych węglowodorów aromatycznych (BTX)","methodology_en":"Monocyclic aromatic hydrocarbons (BTX) concentration","parameters":[{"name":"Zakres","range":"1,2-dichloroetan (0,1 – 50,0) μg/l"},{"name":"benzen","range":"(0,1 – 50,0) μg/l"},{"name":"chlorek winylu","range":"(0,1 – 5,00 ) μg/l"},{"name":"dichlorometan","range":"(0,5 – 50,0) μg/l"},{"name":"heksachlorobutadien","range":"(0,1 – 50,0) μg/l"},{"name":"toluen","range":"(0,1 – 50,0) μg/l"},{"name":"etylobenzen","range":"(0,1 – 50,0) μg/l"},{"name":"o-ksylen","range":"(0,1 – 50,0) μg/l"},{"name":"m+p-ksylen","range":"(0,2 – 100,0) μg/l"},{"name":"styren","range":"(0,1 – 50,0) μg/l"},{"name":"izopropylobenzen","range":"(0,1 – 50,0) μg/l"}],"parameters_en":[{"name":"Range","range":"1,2-dichloroetan (0,1 – 50,0) μg/l"},{"name":"benzene","range":"(0,1 – 50,0) μg/l"},{"name":"vinyl chloride","range":"(0,1 – 5,00 ) μg/l"},{"name":"dichloromethane","range":"(0,5 – 50,0) μg/l"},{"name":"hexachlorobutadiene","range":"(0,1 – 50,0) μg/l"},{"name":"toluene","range":"(0,1 – 50,0) μg/l"},{"name":"ethylbenzene","range":"(0,1 – 50,0) μg/l"},{"name":"o-xylene","range":"(0,1 – 50,0) μg/l"},{"name":"m+p-xylene","range":"(0,2 – 100,0) μg/l"},{"name":"styrene","range":"(0,1 – 50,0) μg/l"},{"name":"isopropylbenzene","range":"(0,1 – 50,0) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie jednopierścieniowych węglowodorów aromatycznych (BTX)\nZakres:\nZakres 1,2-dichloroetan (0,1 – 50,0) μg/l\nbenzen (0,1 – 50,0) μg/l\nchlorek winylu (0,1 – 5,00 ) μg/l\ndichlorometan (0,5 – 50,0) μg/l\nheksachlorobutadien (0,1 – 50,0) μg/l\ntoluen (0,1 – 50,0) μg/l\netylobenzen (0,1 – 50,0) μg/l\no-ksylen (0,1 – 50,0) μg/l\nm+p-ksylen (0,2 – 100,0) μg/l\nstyren (0,1 – 50,0) μg/l\nizopropylobenzen (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie jednopierścieniowych węglowodorów aromatycznych (BTX)\nZakres:\nZakres 1,2-dichloroetan (0,1 – 50,0) μg/l\nbenzen (0,1 – 50,0) μg/l\nchlorek winylu (0,1 – 5,00 ) μg/l\ndichlorometan (0,5 – 50,0) μg/l\nheksachlorobutadien (0,1 – 50,0) μg/l\ntoluen (0,1 – 50,0) μg/l\netylobenzen (0,1 – 50,0) μg/l\no-ksylen (0,1 – 50,0) μg/l\nm+p-ksylen (0,2 – 100,0) μg/l\nstyren (0,1 – 50,0) μg/l\nizopropylobenzen (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda, woda do spozycia przez ludzi, scieki Stezenie jednopierscieniowych weglowodorow aromatycznych (BTX)\nZakres:\nZakres 1,2-dichloroetan (0,1 – 50,0) μg/l\nbenzen (0,1 – 50,0) μg/l\nchlorek winylu (0,1 – 5,00 ) μg/l\ndichlorometan (0,5 – 50,0) μg/l\nheksachlorobutadien (0,1 – 50,0) μg/l\ntoluen (0,1 – 50,0) μg/l\netylobenzen (0,1 – 50,0) μg/l\no-ksylen (0,1 – 50,0) μg/l\nm+p-ksylen (0,2 – 100,0) μg/l\nstyren (0,1 – 50,0) μg/l\nizopropylobenzen (0,1 – 50,0) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Monocyclic aromatic hydrocarbons (BTX) concentration Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Range benzene vinyl chloride dichloromethane hexachlorobutadiene toluene ethylbenzene o-xylene m+p-xylene styrene isopropylbenzene PN-EN ISO 15680:2008","parameters_zh":[{"name":"范围","range":"1,2-dichloroetan (0,1 – 50,0) μg/l"},{"name":"苯","range":"(0,1 – 50,0) μg/l"},{"name":"氯乙烯","range":"(0,1 – 5,00 ) μg/l"},{"name":"二氯甲烷","range":"(0,5 – 50,0) μg/l"},{"name":"六氯丁二烯","range":"(0,1 – 50,0) μg/l"},{"name":"甲苯","range":"(0,1 – 50,0) μg/l"},{"name":"乙苯","range":"(0,1 – 50,0) μg/l"},{"name":"邻二甲苯","range":"(0,1 – 50,0) μg/l"},{"name":"间+对二甲苯","range":"(0,2 – 100,0) μg/l"},{"name":"苯乙烯","range":"(0,1 – 50,0) μg/l"},{"name":"异丙苯","range":"(0,1 – 50,0) μg/l"}],"search_zh":"水、生活饮用水、污水 吹扫捕集气相色谱-质谱法（P&T GC-MS） 范围 苯 氯乙烯 二氯甲烷 六氯丁二烯 甲苯 乙苯 邻二甲苯 间+对二甲苯 苯乙烯 异丙苯 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水、污水","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a5e783f4cc76d93cba39ebf","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Suma BTX ( Benzen, Toluen, Ksylen) (z obliczeń)","methodology_en":"Sum of BTX ( Benzene, Toluene, Xylene) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTX ( Benzen, Toluen, Ksylen) (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Suma BTX ( Benzen, Toluen, Ksylen) (z obliczeń) PN-EN ISO 15680:2008 Woda, woda do spozycia przez ludzi, scieki Suma BTX ( Benzen, Toluen, Ksylen) (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Sum of BTX ( Benzene, Toluene, Xylene) (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水、污水 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5e783f4cc76d93cba39ec0","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli, Escherichia coli","methodology_en":"Coliform bacteria count, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["microbiology","water"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04","search_zh":"水、生活饮用水 大肠菌群数、大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"大肠菌群数、大肠埃希氏菌数"},{"_id":"6a5e783f4cc76d93cba39ec1","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"NPL Escherichia coli i bakterii z grupy coli","methodology_en":"MPN of Escherichia coli and coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"NPL Escherichia coli i bakterii z grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi NPL Escherichia coli i bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi NPL Escherichia coli i bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption MPN of Escherichia coli and coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","search_zh":"水、生活饮用水 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ec2","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","methodology_en":"Clostridium perfringens count including spores","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5e783f4cc76d93cba39ec3","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba mikroorganizmów w 22 oC","methodology_en":"Count of microorganisms at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Liczba mikroorganizmow w 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Count of microorganisms at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ec4","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba mikroorganizmów w 36 oC","methodology_en":"Count of microorganisms at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba mikroorganizmow w 36 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Count of microorganisms at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水（含游泳池水）、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ec5","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A; Procedura 5; Pożywka A-BCYE Matryca A; Procedura 6,7; Pożywka C-GVPC Matryca B; Procedura 6,7; Pożywka C-GVPC"}],"parameters_en":[{"name":"Matrix A; Procedure 5; Medium A-BCYE Matrix A; Procedure 6,7; Medium C-GVPC Matrix B; Procedure 6,7; Medium C-GVPC"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A; Procedura 5; Pożywka A-BCYE Matryca A; Procedura 6,7; Pożywka C-GVPC Matryca B; Procedura 6,7; Pożywka C-GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08+ Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08+ Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A; Procedura 5; Pożywka A-BCYE Matryca A; Procedura 6,7; Pożywka C-GVPC Matryca B; Procedura 6,7; Pożywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+ Ap1:2019-12 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A; Procedura 5; Pozywka A-BCYE Matryca A; Procedura 6,7; Pozywka C-GVPC Matryca B; Procedura 6,7; Pozywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+ Ap1:2019-12","categories":["microbiology","water"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A; Procedure 5; Medium A-BCYE Matrix A; Procedure 6,7; Medium C-GVPC Matrix B; Procedure 6,7; Medium C-GVPC PN-EN ISO 11731:2017-08+ Ap1:2019-12","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08+ Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ec6","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ec7","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach, woda z kąpielisk), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water, bathing water), water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach, woda z kąpielisk), woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda (w tym woda na plywalniach, woda z kapielisk), woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water, bathing water), water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法"},{"_id":"6a5e783f4cc76d93cba39ec8","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda z kąpielisk), woda do spożycia przez ludzi","test_object_en":"Water (including bathing water), water intended for human consumption","methodology":"Liczba Enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda z kąpielisk), woda do spożycia przez ludzi Liczba Enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda z kapielisk), woda do spozycia przez ludzi Liczba Enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including bathing water), water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水（含浴场水）、生活饮用水 粪肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","methodology_zh":"粪肠球菌数","test_object_zh":"水（含浴场水）、生活饮用水"},{"_id":"6a5e783f4cc76d93cba39ec9","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba gronkowców koagulazododatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3: 2000 Załącznik A","norm_bases":["PN-Z-11001-3: 2000 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3: 2000 Załącznik A Woda (w tym woda na plywalniach) Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3: 2000 Zalacznik A","categories":["water"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3: 2000 Załącznik A","search_zh":"水（含游泳池水） 凝固酶阳性葡萄球菌计数 膜过滤法 PN-Z-11001-3: 2000 Załącznik A","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）"},{"_id":"6a5e783f4cc76d93cba39eca","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda z kąpielisk)","test_object_en":"Water (including bathing water)","methodology":"NPL Enterokoków kałowych","methodology_en":"MPN of intestinal enterococci","parameters":[],"parameters_en":[],"technique":"Metoda zminiaturyzowana","techniques":["Metoda zminiaturyzowana"],"technique_en":"Miniaturized method","computed":[],"computed_en":[],"activity":"NPL Enterokoków kałowych\nMetoda zminiaturyzowana","reference":"PN-EN ISO 7899-1:2002","norm_bases":["PN-EN ISO 7899-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda z kąpielisk) NPL Enterokoków kałowych\nMetoda zminiaturyzowana PN-EN ISO 7899-1:2002 Woda (w tym woda z kapielisk) NPL Enterokokow kalowych\nMetoda zminiaturyzowana PN-EN ISO 7899-1:2002","categories":["water"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including bathing water) MPN of intestinal enterococci Miniaturized method PN-EN ISO 7899-1:2002","search_zh":"水（含浴场水） 微量法 PN-EN ISO 7899-1:2002","technique_zh":"微量法","test_object_zh":"水（含浴场水）"},{"_id":"6a5e783f4cc76d93cba39ecb","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Woda (w tym woda z kąpielisk)","test_object_en":"Water (including bathing water)","methodology":"NPL Escherichia coli","methodology_en":"MPN Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda zminiaturyzowana","techniques":["Metoda zminiaturyzowana"],"technique_en":"Miniaturized method","computed":[],"computed_en":[],"activity":"NPL Escherichia coli\nMetoda zminiaturyzowana","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda z kąpielisk) NPL Escherichia coli\nMetoda zminiaturyzowana PN-EN ISO 9308-3:2002 Woda (w tym woda z kapielisk) NPL Escherichia coli\nMetoda zminiaturyzowana PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including bathing water) MPN Escherichia coli Miniaturized method PN-EN ISO 9308-3:2002","search_zh":"水（含浴场水） 微量法 PN-EN ISO 9308-3:2002","technique_zh":"微量法","test_object_zh":"水（含浴场水）"},{"_id":"6a5e783f4cc76d93cba39ecc","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(0,6 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,6 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,6 – 6,0) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5e783f4cc76d93cba39ecd","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3,0 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3,0 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5e783f4cc76d93cba39ece","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","methodology_en":"Chemical oxygen demand COD-Cr","parameters":[{"name":"Zakres","range":"(15 – 10000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(15 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(15 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a5e783f4cc76d93cba39ecf","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39ed0","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 50000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 50000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 50000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa\nZakres (5 – 50000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa\nZakres (5 – 50000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 50000) μS/cm"}],"search_zh":"污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39ed1","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39ed2","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,5 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,5 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (0,5 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 250) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39ed3","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie cyjanków wolnych i związanych","methodology_en":"Free and combined cyanide concentration","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych i związanych\nZakres (0,005 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"P N-80/C-04603.01","norm_bases":["P N-80/C-04603.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie cyjanków wolnych i związanych\nZakres (0,005 – 1,0) mg/l\nMetoda spektrofotometryczna P N-80/C-04603.01 Scieki Stezenie cyjankow wolnych i zwiazanych\nZakres (0,005 – 1,0) mg/l\nMetoda spektrofotometryczna P N-80/C-04603.01","categories":["water"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Free and combined cyanide concentration Spectrophotometric method Range P N-80/C-04603.01","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/l"}],"search_zh":"污水 分光光度法 范围 P N-80/C-04603.01","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5e783f4cc76d93cba39ed4","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH Potentiometric method Range PN-EN 12176:2004","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a5e783f4cc76d93cba39ed5","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha masa / zawartość wody","methodology_en":"Dry matter / water content","parameters":[{"name":"Zakres","range":"(0,10 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha masa / zawartość wody\nZakres (0,10 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha masa / zawartość wody\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha masa / zawartosc wody\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry matter / water content Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(0,10 – 99,9) %"}],"search_zh":"污泥 干物质 / 水分含量 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质 / 水分含量"},{"_id":"6a5e783f4cc76d93cba39ed6","lab_id":"69ad52a3de79e566650fb173","country":"PL","accr_number":"AB 216","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,10 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,10 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-EN 12879:2004 Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 12879:2004","parameters_zh":[{"name":"范围","range":"(0,10 – 99,9) %"}],"search_zh":"污泥 干物质烧失量（LOI） 重量法 范围 PN-EN 12879:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）"}],"has_pdf":true}