🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL
Water & wastewaterEnvironmentElectronics & EMC
GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 199 (Warszawa, Poland). Its accreditation scope covers 199 test methods in the following areas: Water & wastewater, Environment, Electronics & EMC. Test objects include: Water, wastewater, Sewage sludge, Soil, Water. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 199
- Methods in scope: 199
- Types of test objects: 21
- Techniques used: 26
- City: Warszawa, Poland
- Accreditation number
- AB 199
- Accreditation body
- PCA
- Address
- ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W POZNANIU
- City
- Warszawa, Poland
What this laboratory tests (21)
- Water, wastewater — 95 methods
- Sewage sludge — 22 methods
- Soil — 19 methods
- Water — 11 methods
- Waste gases — 10 methods
- Odpady O) kod: 170503* 170504 — 6 methods
- Odpady O) kod: 190805 — 6 methods
- Osady ściekowe, Odpady O) kod: 190805 — 5 methods
- Wastewater — 5 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements — 2 methods
- General environment – impulse noise from installations, equipment and industrial plants — 2 methods
- General environment – noise from airports — 2 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- General environment – noise from roads, railway lines and tramway lines — 2 methods
- and 6 more
Analytical techniques used (26)
- Spectrophotometric method — 42 methods
- Gravimetric method — 33 methods
- Titrimetric method — 29 methods
- Electrochemical method — 11 methods
- Potentiometric method — 9 methods
- Direct measurement method — 7 methods
- Infrared spectrometry method (IR) — 6 methods
- Ion chromatography with conductometric detection (IC-CD) — 5 methods
- Gas chromatography with flame ionization detection (GC-FID) — 4 methods
- Conductometric method — 3 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 3 methods
- Calorimetric method — 2 methods
- Cold vapour atomic absorption spectrometry (CVAAS) — 2 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD) — 2 methods
- Aspiration method — 1 method
- and 11 more
Laboratory sections (6)
- Pracownia w Koninie — 53 methods
- Pracownia Terenowa — 36 methods
- Pracownia w Pile — 36 methods
- Pracownia w Kaliszu — 25 methods
- Pracownia w Poznaniu — 25 methods
- Pracownia w Lesznie — 24 methods
Laboratory locations
- ODDZIAŁ W POZNANIU — AB 199 ul. Czarna Rola 4
- Pracownia Terenowa — ul. Czarna Rola 4, 61-625 Poznań
- Pracownia w Poznaniu — ul. Czarna Rola 4, 61-625 Poznań
- Pracownia w Kaliszu — ul. Piwonicka 19, 62-800 Kalisz
- Pracownia w Koninie — ul. Kard. Stefana Wyszyńskiego 3a, 62-510 Konin
- Pracownia w Lesznie — ul. 17 Stycznia 4, 64-100 Leszno
- Pracownia w Pile — ul. Motylewska 5a, 64-920 Piła
Accreditation scope — test methods (199)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Pracownia Terenowa | |||||
| 1 | Water | Sampling for chemical and physical testing | PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2 | ||
| 2 | Water | Temperature Range (0,0 – 50,0) oC |
PN-77/C-04584 | ||
| 3 | Water | Dissolved oxygen concentration Range (0,5 – 15,0) mg/l O2 Oxygen saturation Range (6 – 150) % |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 4 | Water | Dissolved oxygen concentration Range (0,5 – 15,0) mg/l O2 |
Optical method | ISO 17289:2014 | |
| 5 | Wastewater | Sampling for chemical and physical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 6 | Wastewater | Temperature Range (0,0 – 50,0) oC |
PN-77/C-04584 | ||
| 7 | Water, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 8 | Water, wastewater | Electrical conductivity Range (10 – 10000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 9 | Sewage sludge | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 | PN-Z-15011-1:1998 | ||
| 10 | Sewage sludge, Waste O): code 19 08 05 | Sampling for microbiological and parasitological testing Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
PN-EN ISO 5667-13:2011 | ||
| 11 | Soil | Sampling for chemical and physical testing | PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 | ||
| 12 | Odpady O): kod 17 05 03, 17 05 04, 19 08 05 | Sampling for chemical and physical testing Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
PN-ISO 10381-5:2009 | PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8 | ||
| 13 | Waste | Intervention testing (according to Programme DAB-11) | PB-11/CLB wyd. 1 z 25.09.2023 r. | ||
| 14 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25,0 – 130,0) dB |
Direct measurement method | Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | |
| 15 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | ||
| 16 | General environment – noise from roads, railway lines and tramway lines | A-weighted equivalent sound level A-weighted sound exposure level Range (25,0 – 130,0) dB |
Direct measurement method | Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H | |
| 17 | General environment – noise from roads, railway lines and tramway lines | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H | ||
| 18 | General environment – impulse noise from installations, equipment and industrial plants | A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level Range (25,0 – 130,0) dB |
Direct measurement method | Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | |
| 19 | General environment – impulse noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | ||
| 20 | General environment – noise from airports | A-weighted equivalent sound level A-weighted sound exposure level Range (25,0 – 130,0) dB |
Direct measurement method | Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H | |
| 21 | General environment – noise from airports | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H | ||
| 22 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength at 50 Hz frequency Range 1 V/m – 30 kV/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 23 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density at 50 Hz frequency Range 1,0 μT – 10 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 24 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength at 50 Hz frequency (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 25 | Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements | Electric field strength: in the frequency range from 10 MHz – 60 GHz Range 0,3 V/m – 300 V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 26 | Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements | Magnetic field strength: in the frequency range from 10 MHz to 60 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 27 | Waste gases | SO2, NOx, CO, CO2 and O2 concentration SO2 ( 12– 2860) mg/m3 CO (7 – 2500) mg/m3 CO2 (0,2 – 18,0) % NOx (2 – 925) mg/m3 O2 ( 0,4 – 21,0) % Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Non-dispersive infrared spectrometry (NDIR); Chemiluminescence method; Paramagnetic method | PN-ISO 10396:2001 | |
| 28 | Waste gases | Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, CO2 (calculated) Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
PN-ISO 10396:2001 | ||
| 29 | Waste gases | Sampling for determination of dust concentration Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
PN-Z-04030-7:1994 | ||
| 30 | Waste gases | Dust concentration Range ( 0,002– 1,0) g/m3 Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Gravimetric method | PN-Z-04030-7:1994 | |
| 31 | Waste gases | Dust emission (calculated) Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
PN-Z-04030-7:1994 | ||
| 32 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 33 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Aspiration method | PN-EN 13649:2005 | |
| 34 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
PN-EN 13649:2005 | ||
| 35 | Waste gases | Sampling for determination of concentrations of organic compounds Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Aspiration method using activated carbon/ silica gel/absorbing solutions | PN-Z-04008-4:1999 | |
| 36 | Waste gases | Emission of organic compounds (calculated) Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
PN-Z-04008-4:1999 | ||
| Pracownia w Poznaniu | |||||
| 37 | Wastewater | Mercury concentration Range (0,50 – 100) μg/l |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN ISO 12846:2012+Ap1:2016-07 | |
| 38 | Water, wastewater | Anion concentrations Nitrate nitrogen (0,10 – 100) mg/l Fluorides (0,040 – 20) mg/l Chlorides (0,40 – 400) mg/l Sulfates (0,40 – 400) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 + AC:2012 | |
| 39 | Water, wastewater | Ammonium nitrogen concentration Range (0,025 – 10) mg/l |
Spectrophotometric method | PN ISO 7150-1:2002 | |
| 40 | Water, wastewater | Anionic surfactant concentration (anionic surface-active agents) Range (0,060 – 50) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 41 | Water, wastewater | Arsenic concentration Range (5,0 – 100) μg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 42 | Water, wastewater | Metal concentrations Barium (0,0050 – 20) mg/l Boron (0,010 – 20) mg/l Chromium (0,0050 – 20) mg/l Zinc (0,020 – 20) mg/l Phosphorus (0,010-100) mg/l Aluminium (0,050 – 20) mg/l Cadmium (0,0050 – 20) mg/l Cobalt (0,010 – 20) mg/l Manganese (0,010 – 20) mg/l Copper (0,0050 – 20) mg/l Molybdenum (0,012 – 20) mg/l Nickel (0,020 – 20) mg/l Lead (0,020 – 20) mg/l Titanium (0,010 – 20) mg/l Vanadium (0,0050 – 20) mg/l Iron (0,020 – 20) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 43 | Water, wastewater | Total dissolved solids (TDS) Range (200 – 10000) mg/l |
Gravimetric method | PN-EN 15216: 2022-03 | |
| 44 | Water, wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 45 | Water, wastewater | Permanganate index Range (0,50 – 100) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 46 | Water, wastewater | Biochemical oxygen demand BOD5, BOD2+5 Range (2 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 47 | Water, wastewater | Biochemical oxygen demand BOD5, BOD2+5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 48 | Water, wastewater | Total phosphorus concentration Range (0,015 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010 | |
| 49 | Water, wastewater | Orthophosphate concentration Range (0,010 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 | |
| 50 | Water, wastewater | Nitrite nitrogen concentration Range (0,0017 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 51 | Water, wastewater | Ammonium nitrogen concentration Range (0,61 – 300) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 52 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,30 – 400) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 53 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (30 – 10000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 54 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (7,00 – 100) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 55 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wyd.1 z 16.01.2026 r. | ||
| 56 | Soil, sewage sludge, waste o): code 19 08 05 | Mercury content Range (0,10 – 33) mg/kg Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2 | PN-EN 16173:2012 | |
| 57 | Soil, sewage sludge, waste o): code 19 08 05 | Metal content: Chromium (1,0 – 1600) mg/kg Cadmium (1,0 – 1600) mg/kg Copper (1,0 – 1600) mg/kg Nickel (4,0 – 1600) mg/kg Lead (4,0 – 1600) mg/kg Zinc (4,0 – 8000) mg/kg Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012 | |
| 58 | Soil | Dry matter Range (30,0 – 99,0) % Water content Range (1,0 – 70,0) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 59 | Soil | pH - in H20 Range (4,0 – 10,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 60 | Soil | Electrical conductivity Range (20 – 12900) μS/cm |
Conductometric method | PN-ISO 11265+AC1:1997 | |
| 61 | Soil | Arsenic content: Range (4,0 – 1600) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012 | |
| Pracownia w Kaliszu | |||||
| 62 | Water | Permanganate index Range (0,50 – 50) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 63 | Water, wastewater | Total organic carbon concentration (TOC) Range (1,0 – 1000) mg/l |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | |
| 64 | Water, wastewater | Ammonium nitrogen concentration Range (0,010 – 8,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 65 | Water, wastewater | Nitrite nitrogen concentration Range (0,001 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 66 | Water, wastewater | Kjeldahl nitrogen concentration Range (2,0 – 500) mg/l Range (0,20 – 5,0) mg/l |
Titrimetric method; Spectrophotometric method | PN-EN 25663:2001 | |
| 67 | Water, wastewater | Total phosphorus concentration Range (0,010 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010 | |
| 68 | Water, wastewater | Orthophosphate concentration P (0,005 – 5,00) mg/l PO4 (0,015 – 15,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010 | |
| 69 | Water, wastewater | Concentration of substances extractable with petroleum ether Range (2,0 – 1000) mg/l |
Gravimetric method | PN-86/C-04573-01 | |
| 70 | Water, wastewater | Total dissolved solids (TDS) Range (50,0 – 5000) mg/l |
Gravimetric method | PN-EN 15216: 2022-03 | |
| 71 | Water, wastewater | Total suspended solids (TSS) Range (4,0 – 10000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 72 | Water, wastewater | Ammonium nitrogen concentration Range (2,0 – 500) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 73 | Water, wastewater | Biochemical oxygen demand - BOD5, BOD2+5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 74 | Water, wastewater | Biochemical oxygen demand - BOD5, BOD2+5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 75 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wyd.1 z 16.01.2026 r. | ||
| 76 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (10,0 – 5000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 77 | Sewage sludge | Total phosphorus content Range (0,0025 – 200) g/kg Range (0,00025 – 20) % |
Spectrophotometric method | PN-EN 14672:2006 | |
| 78 | Sewage sludge | Loss on ignition of dry matter (LOI) Range (10,0 – 90,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 79 | Sewage sludge | Dry residue Range (5,0 – 80,0) % Water content Range (20,0 – 95,0) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 80 | Sewage sludge | Ammonium nitrogen content Range (0,05 – 100) g/kg Range (0,005 – 10) % |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 81 | Sewage sludge | Kjeldahl nitrogen content Range (0,15 –100) g/kg Range (0,015 – 10) % |
Titrimetric method | PN-EN 13342:2002 | |
| 82 | Sewage sludge | pH - in H20 Range 3,0 – 10,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 83 | Soil | Dry matter Range (20,0 – 99,0) % Water content Range (1,0 – 80,0) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 84 | Soil | pH - in H20, pH - in KCl Range 3,0 – 10,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 85 | Odpady O) kod: 19 08 05 19 12 12 | Gross calorific value Range (5000 – 30000) kJ/kg Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Calorimetric method | PN-EN ISO 18125:2017-07 | |
| 86 | Solid fuels: solid biomass – solid biofuel | Gross calorific value Range (5000 – 30000) kJ/kg |
Calorimetric method | PN-EN ISO 18125:2017-07 | |
| Pracownia w Koninie | |||||
| 87 | Water | Anion concentrations Nitrates (0,10 – 50) mg/l Chlorides (1,0 – 100) mg/l Fluorides (0,10 – 2,0) mg/l Sulfates (1,0 – 100) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 + AC:2012 | |
| 88 | Water | Nitrate nitrogen concentration (calculated) | PN-EN ISO 10304-1:2009 + AC:2012 | ||
| 89 | Water | Concentration of polycyclic aromatic hydrocarbons (PAH) Acenaphthene (0,0003 – 0,10) μg/l Anthracene (0,001 – 0,10) μg/l Benzo-a-anthracene (0,003 – 0,10) μg/l Benzo-b-fluoranthene (0,0006 – 0,10) μg/l Benzo-k-fluoranthene (0,0006 – 0,10) μg/l Benzo-g,h,i-perylene (0,0005 – 0,10) μg/l Benzo-a-pyrene (0,00005 – 0,10) μg/l Chrysene (0,004 – 0,10) μg/l Dibenzo(a,h)anthracene (0,002 – 0,10) μg/l Phenanthrene (0,0012 – 0,10) μg/l Fluoranthene (0,0018 – 0,10) μg/l Fluorene (0,0006 – 0,10) μg/l Indeno(1,2,3-c,d)piren (0,0005 – 0,10) μg/l Naphthalene (0,0033 – 0,10) μg/l Pyrene (0,0085 – 0,10) μg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD). | PN-EN ISO 17993:2005 | Benzo-g,h,i-perylen | |
| 90 | Water | Sum of selected PAH (calculated) | PN-EN ISO 17993:2005 | ||
| 91 | Wastewater | Anion concentrations Nitrates (0,10 – 100) mg/l Chlorides (1,0 – 1000) mg/l Sulfates (1,0 – 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 + AC:2012 | |
| 92 | Wastewater | Nitrate nitrogen concentration (calculated) | PN-EN ISO 10304-1:2009 + AC:2012 | ||
| 93 | Water, wastewater | Concentration of polycyclic aromatic hydrocarbons (PAH) Acenaphthene (0,0003 – 4,0) μg/l Anthracene (0,001 – 0,08) μg/l Benzo-a-anthracene (0,003 – 0,20) μg/l Benzo-b-fluoranthene (0,004 – 0,08) μg/l Benzo-k-fluoranthene (0,002 – 0,08) μg/l Benzo-g, h, i-perylene (0,0005 – 0,32)μg/l Benzo-a-pyrene (0,002 – 0,20) μg/l Chrysene (0,005 – 0,20) μg/l Dibenzo(a,h)anthracene (0,002 – 0,80) μg/l Phenanthrene (0,002 – 0,16) μg/l Fluoranthene (0,004 – 0,20) μg/l Fluorene (0,0006 – 0,40) μg/l Indeno(1,2,3-c,d)piren (0,0005 – 0,20) μg/l Naphthalene (0,004 – 2,0) μg/l Pyrene (0,009 – 0,40) μg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-08/PO wyd. 01 z 16.06.2020 r. | |
| 94 | Water, wastewater | Sum of selected PAH (calculated) | PB-08/PO wyd. 01 z 16.06.2020 r. | ||
| 95 | Water, wastewater | Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO) Range (2,0 – 1000) mg/l |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | |
| 96 | Water, wastewater | Ammonium nitrogen concentration Range (0,010 – 30) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 97 | Water, wastewater | Nitrate nitrogen concentration Range (0,01 – 100) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 98 | Water, wastewater | Nitrite nitrogen concentration Range (0,0017 – 0,25) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 99 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (7,00 – 1000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 100 | Water, wastewater | Total phosphorus concentration Range (0,010 – 65,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010 | |
| 101 | Water, wastewater | Orthophosphate concentration Range (0,010 – 25,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 | |
| 102 | Water, wastewater | Phenol index (volatile phenols) Range (0,003 – 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
| 103 | Water, wastewater | Anionic surfactant concentration (anionic surface-active agents) Range (0,050 – 5,0) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 104 | Water, wastewater | Sulfate concentration Range (4 – 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 105 | Water, wastewater | Total dissolved solids (TDS) Range (50,0 – 5000) mg/l |
Gravimetric method | PN-EN 15216: 2022-03 | |
| 106 | Water, wastewater | Total suspended solids (TSS) Range (1,4 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 107 | Water, wastewater | Ammonium nitrogen concentration Range (0,50 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 108 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,25 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 109 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (30 – 10 000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 110 | Water, wastewater | Chloride concentration Range (2 – 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 111 | Water, wastewater | Permanganate index Range (1,0 – 10,0) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 112 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 113 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,60 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 114 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wyd.1 z 16.01.2026 r. | ||
| 115 | Sewage sludge | Total phosphorus content Range (2,5 – 25) g/kg Range (0,25 – 2,5) % |
Spectrophotometric method | PN-EN 14672:2006 | |
| 116 | Sewage sludge | Loss on ignition of dry matter (LOI) Range (2,5 – 97,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 117 | Sewage sludge | Dry residue Range (4,0 – 98,0) % Water content Range (2,0 – 96,0) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 118 | Sewage sludge | Ammonium nitrogen content Range (1,0 – 50) g/kg Range (0,10 – 5,0) % |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 119 | Sewage sludge | Kjeldahl nitrogen content Range (5,0 – 80) g/kg Range (0,5 – 8,0) % |
Titrimetric method | PN-EN 13342:2002 | |
| 120 | Sewage sludge | pH - in H20 Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 121 | Osady ściekowe, Odpady O) kod: 190805 | Total organic carbon (TOC) content Range (1,0 – 400) g/kg Range (0,10 – 40) % Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Infrared spectrometry method (IR) | PN-EN ISO 15936:2022-07 metoda B (bezpośrednia) | |
| 122 | Soil | pH - in H20 Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 123 | Soil | Electrical conductivity Range (10 – 10 000) μS/cm |
Conductometric method | PN-ISO 11265+AC1:1997 | |
| 124 | Soil | Polycyclic aromatic hydrocarbons (PAH) content Acenaphthene (0,007 – 10) mg/kg Anthracene (0,001 – 10) mg/kg Benzo-a-anthracene (0,001 – 10) mg/kg Benzo-b-fluoranthene (0,001 – 10) mg/kg Benzo-k-fluoranthene (0,001 – 10) mg/kg Benzo-g,h,i-perylene (0,001 – 10) mg/kg Benzo-a-pyrene (0,001 – 10) mg/kg Chrysene (0,001 – 10) mg/kg Phenanthrene (0,001 – 10) mg/kg Fluoranthene (0,001 – 10) mg/kg Fluorene (0,001 – 10) mg/kg Dibenzo(a,h)anthracene (0,002 – 10) mg/kg Indeno-1,2,3-c,d-pyrene (0,001 – 10) mg/kg Naphthalene (0,003 – 10) mg/kg Pyrene (0,001 – 10) mg/kg |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-EN 17503:2022-07 | |
| 125 | Soil | Sum of selected PAH (calculated) | PN-EN 17503:2022-07 | ||
| 126 | Soil | Total organic carbon (TOC) content Range (1,0 – 400) g/kg Range (0,10 – 40) % |
Infrared spectrometry method (IR) | PN-EN ISO 15936:2022-07 metoda B (bezpośrednia) | |
| 127 | Soil | Dry matter Range (30,0 - 99,7) % Water content Range (0,3 – 70,0) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 128 | Odpady O) kod: 190805 | Anion concentrations Nitrates (1,0 – 1000) mg/kg (0,10 – 100) mg/l Chlorides (10 – 10 000) mg/kg (1,0 – 1000) mg/l Sulfates (10 – 10 000) mg/kg (1,0 – 1000) mg/l Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457- 2:2006 | |
| 129 | Odpady O) kod: 190805 | Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO) Range (20 – 10 000) mg/kg Range (2,0 – 1000) mg/l Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | PN-EN 12457- 2:2006 | |
| 130 | Odpady O) kod: 190805 | Phenol index (volatile phenols) Range (0,03 – 1,0) mg/kg Range (0,003 – 0,10) mg/l Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Spectrophotometric method | PN-ISO 6439:1994 | PN-EN 12457- 2:2006 | |
| 131 | Odpady O) kod: 190805 | Sulfate concentration Range (40 – 50 000) mg/kg Range (4 – 5000) mg/l Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-ISO 9280:2002 | PN-EN 12457- 2:2006 | |
| 132 | Odpady O) kod: 190805 | Total dissolved solids (TDS) Range (500 – 50 0000) mg/kg Range (50 – 5000) mg/l Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15216: 2022-03 | PN-EN 12457- 2:2006 | |
| 133 | Odpady O) kod: 190805 | Chloride concentration Range (20 – 50 000) mg/kg Range (2 – 5000) mg/l Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Titrimetric method | PN-ISO 9297:1994 | PN-EN 12457- 2:2006 | |
| 134 | Odpady O) kod: 170503* 170504 | Anion concentrations Nitrates (1,0 – 1000) mg/kg (0,10 – 100) mg/l Chlorides (10 – 10 000) mg/kg (1,0 – 1000) mg/l Sulfates (10 – 10 000) mg/kg (1,0 – 1000) mg/l Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457-2:2006 | |
| 135 | Odpady O) kod: 170503* 170504 | Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO) Range (20 – 10 000) mg/kg Range (2,0 – 1000) mg/l Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | PN-EN 12457-2:2006 | |
| 136 | Odpady O) kod: 170503* 170504 | Phenol index (volatile phenols) Range (0,03 – 1,0) mg/kg Range (0,003 – 0,10) mg/l Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Spectrophotometric method | PN-ISO 6439:1994 | PN-EN 12457-2:2006 | |
| 137 | Odpady O) kod: 170503* 170504 | Sulfate concentration Range (40 – 50 000) mg/kg Range (4 – 5000) mg/l Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-ISO 9280:2002 | PN-EN 12457-2:2006 | |
| 138 | Odpady O) kod: 170503* 170504 | Total dissolved solids (TDS) Range (500 – 50 0000) mg/kg Range (50 – 5000) mg/l Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15216: 2022-03 | PN-EN 12457-2:2006 | |
| 139 | Odpady O) kod: 170503* 170504 | Chloride concentration Range (20 – 50 000) mg/kg Range (2 – 5000) mg/l Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Titrimetric method | PN-ISO 9297:1994 | PN-EN 12457-2:2006 | |
| Pracownia w Lesznie | |||||
| 140 | Water, wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 141 | Water, wastewater | Permanganate index Range (0,50 – 100) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 142 | Water, wastewater | Biochemical oxygen demand BOD5 Range (1 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 143 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 144 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (10,0 – 5000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 145 | Water, wastewater | Ammonium nitrogen concentration Range (0,010 – 50) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 146 | Water, wastewater | Nitrite nitrogen concentration Range (0,001 – 2,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 147 | Water, wastewater | Nitrate nitrogen concentration Range (0,10 – 200) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 148 | Water, wastewater | Total phosphorus concentration Range (0,018 – 200) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010 | |
| 149 | Water, wastewater | Orthophosphate concentration Range (0,005 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 150 | Water, wastewater | Sulfate concentration Range (10 – 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 151 | Water, wastewater | Total dissolved solids (TDS) Range (50,0 – 1000) mg/l |
Gravimetric method | PN-EN 15216: 2022-03 | |
| 152 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,30 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 153 | Water, wastewater | Chloride concentration Range (5 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 154 | Water, wastewater | Calcium concentration Range (2 – 200) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 155 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wyd.1 z 16.01.2026 r. | ||
| 156 | Sewage sludge | Ammonium nitrogen content Range (1,0 – 100) g/kg Range (0,10 - 10) % |
Spectrophotometric method | PN-EN 14671:2007 | |
| 157 | Sewage sludge | Total phosphorus content Range (0,0045 – 50) g/kg Range (0,00045 – 5) % |
Spectrophotometric method | PN-EN 14672:2006 | |
| 158 | Sewage sludge | Dry residue Range (0,1 – 99,9) % Water content Range (0,1 – 99,9) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 159 | Sewage sludge | Loss on ignition of dry matter (LOI) Range (0,1 – 99,9) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 160 | Sewage sludge | Kjeldahl nitrogen content Range (0,350 – 100) g/kg Range (0,035 – 10) % |
Titrimetric method | PN-EN 13342:2002 | |
| 161 | Sewage sludge | pH – in H20 Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 162 | Soil | Dry matter Range (0,1 – 99,9) % Water content Range (0,1 – 99,9) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 163 | Soil | pH – in H20 Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| Pracownia w Pile | |||||
| 164 | Water | Metal concentrations Antimony (0,0003 – 10) mg/l Arsenic (0,001 – 10) mg/l Barium (0,001 – 10) mg/l Beryllium (0,0002 – 10) mg/l Boron (0,010 – 10) mg/l Chromium (0,0005 – 10) mg/l Tin (0,001 – 10) mg/l Aluminium (0,005 – 10) mg/l Cadmium (0,00002 – 10) mg/l Cobalt (0,001 – 10) mg/l Copper (0,001 – 10) mg/l Molybdenum (0,001 – 10) mg/l Nickel (0,001 – 10) mg/l Lead (0,0003 – 10) mg/l Selenium (0,002 – 10) mg/l Silver (0,001 – 10) mg/l Thallium (0,0005 – 10) mg/l Titanium (0,001 – 10) mg/l Vanadium (0,001 – 10) mg/l |
Inductively coupled plasma mass spectrometry method (ICP- MS) | PN-EN ISO 17294-2: 2024-04 | |
| 165 | Water | Mercury concentration Range (0,0080 – 1,0) μg/l |
Atomic fluorescence spectrometry method (AFS) | PN-EN ISO 17852:2009 | |
| 166 | Water, wastewater | Petroleum hydrocarbons - Mineral oil index Range (0,010 – 50) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 167 | Water, wastewater | Formic aldehyde (formaldehyde) concentration Range (0,015 – 2,0) mg/l |
Spectrophotometric method | PN-71/C-04593 | |
| 168 | Water, wastewater | Ammonium nitrogen concentration Range (0,002 – 30) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 169 | Water, wastewater | Nitrate nitrogen concentration Range (0,01 – 100) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 170 | Water, wastewater | Nitrite nitrogen concentration Range (0,001 – 20) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 171 | Water, wastewater | Chromium(VI) concentration Concentration range (0,005 – 1,4) mg/l |
Spectrophotometric method | PN-77/C-04604.02 | PN-77/C-04604.08 | |
| 172 | Water, wastewater | Chromium(VI) concentration Concentration range (5,0 – 50) μg/l |
Spectrophotometric method | PN-EN ISO 18412:2007 | |
| 173 | Water, wastewater | Total phosphorus concentration Range (0,009 – 160) mg/l P |
Spectrophotometric method | PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010 | |
| 174 | Water, wastewater | Orthophosphate concentration Range (0,003 – 160) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 | |
| 175 | Water, wastewater | Phenol index (volatile phenols) Range (0,003 – 0,50) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
| 176 | Water, wastewater | Sulfate concentration Range (10 – 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 177 | Water, wastewater | Concentration of substances extractable with petroleum ether Range (1,0 – 1000) mg/l |
Gravimetric method | PN-86/C-04573/01 | |
| 178 | Water, wastewater | Total dissolved solids (TDS) Range (50,0 – 10000) mg/l |
Gravimetric method | PN-EN 15216: 2022-03 | |
| 179 | Water, wastewater | Total suspended solids (TSS) Range (1,4 – 20000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 180 | Water, wastewater | Ammonium nitrogen concentration Range (0,40 – 5000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 181 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,30 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 182 | Water, wastewater | Chemical oxygen demand - COD-Cr Range (30 –10000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 183 | Water, wastewater | Chloride concentration Range (2 – 10000) mg/l |
Titration method | PN-ISO 9297:1994 | |
| 184 | Water, wastewater | Permanganate index Range (0,40 – 500) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 185 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (1 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 186 | Water, wastewater | Chemical oxygen demand – COD-Cr Range (7,00 – 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 187 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 188 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wyd.1 z dnia 16.01.2026 r. | ||
| 189 | Sewage sludge | Ammonium nitrogen content Range (0,011 – 15) % Range (0,11 – 150) g/kg |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 190 | Sewage sludge | Kjeldahl nitrogen content Range (0,24 – 15) % Range (2,4 – 150) g/kg |
Titrimetric method | PN-EN 13342:2002 | |
| 191 | Sewage sludge | pH - in H20 Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 192 | Osady ściekowe, Odpady O) kod: 190805 | Total phosphorus content Range (0,01 – 5,0) % Range (0,10 – 50) g/kg Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Spectrophotometric method | PN-EN 14672:2006 | |
| 193 | Osady ściekowe, Odpady O) kod: 190805 | Dry residue Range (0,1 – 99,9) % Water content Range (0,1 – 99,9) % Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 194 | Osady ściekowe, Odpady O) kod: 190805 | Loss on ignition of dry matter (LOI) Range (1,2 – 85,0) % Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15935:2022-01 | |
| 195 | Osady ściekowe, Odpady O) kod: 190805 | Kjeldahl nitrogen content Range (0,24 – 15) % Range (2,4 – 150) g/kg Regulated area: O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Titrimetric method | PN-EN 13342:2002 | |
| 196 | Soil | Content of hydrocarbons C10 - C40 Range (30 – 10000) mg/kg |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 16703:2011 | |
| 197 | Soil | Gasoline total (C6 – C12 hydrocarbons) Range (1,0 – 500) mg/kg |
Gas chromatography with flame ionization detection (GC-FID) | PB-06/PO wyd. 01 z 16.06.2020 r. | |
| 198 | Soil | Mineral oil content (C12 – C35 hydrocarbons) Range (20 – 10000) mg/kg |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 16703:2011 | |
| 199 | Soil | Dry matter Range (35,0 – 99,9) % Water content Range (0,1 – 65,0) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
Reference standards (88)
Benzo-g,h,i-perylen
ISO 17289:2014
PB-06/PO wyd. 01 z 16.06.2020 r.
PB-08/PO wyd. 01 z 16.06.2020 r.
PB-11/CLB wyd. 1 z 25.09.2023 r.
PB-26/CLB wyd.1 z 16.01.2026 r.
PB-26/CLB wyd.1 z dnia 16.01.2026 r.
PN ISO 7150-1:2002
PN-71/C-04593
PN-77/C-04584
PN-77/C-04604.02
PN-77/C-04604.08
PN-82/C-04576/08
PN-86/C-04573-01
PN-86/C-04573/01
PN-EN 12457- 2:2006
PN-EN 12457-2:2006
PN-EN 13342:2002
PN-EN 13649:2005
PN-EN 14671:2007
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 15216: 2022-03
PN-EN 15935:2022-01
PN-EN 16173:2012
PN-EN 17503:2022-07
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10304-1:2009 + AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03 Metoda A
PN-EN ISO 11885:2009
PN-EN ISO 11885:2009 z wyłączeniem pkt. 9
PN-EN ISO 12846:2012+Ap1:2016-07
PN-EN ISO 15586:2005
PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)
PN-EN ISO 16703:2011
PN-EN ISO 17294-2: 2024-04
PN-EN ISO 17852:2009
PN-EN ISO 17993:2005
PN-EN ISO 18125:2017-07
PN-EN ISO 18412:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 10396:2001
PN-ISO 11265+AC1:1997
PN-ISO 15705:2005
PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2
PN-ISO 5667-4:2017-10
PN-ISO 6058:1999
PN-ISO 6060:2006
PN-ISO 6439:1994
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-R-04031:1997
PN-Z-04008-4:1999
PN-Z-04030-7:1994
PN-Z-15011-1:1998
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H