{"lab":{"_id":"69ad52a3de79e566650fb169","accr_number":"AB 199","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W POZNANIU","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":199,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_199.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w poznaniu water other pharma electronics microbiology environment metrology materials petro food","status":"active","updated_at":"2026-03-08T14:51:05.064Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:38:19.259Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20199,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/30/P, C/31/P, C/32/P, C/36/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, osadów ściekowych, gleby, odpadów, gazów odlotowych","en":"Chemical tests and sampling of water, sewage, sediments, soil, waste, waste gases"},{"codes":"G/34, G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne), gazów odlotowych","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field), waste gases"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P, N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek: wody, ścieków, osadów ściekowych, gleby odpadów, gazów odlotowych","en":"Tests of physical properties and sampling of water, sewage, sediments, soil, waste, waste gases"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"P/32, P36","pl":"Pobieranie próbek osadów ściekowych, odpadów","en":"Sampling of sediments, waste"}],"issue":{"no":"33","date":"12.08.2026"},"parse_date":"2026-08-17T15:38:19.259Z","parse_source":"agent-claude-code","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ W POZNANIU","address":"AB 199 ul. Czarna Rola 4","city":null,"postal":null},{"name":"Pracownia Terenowa","address":"ul. Czarna Rola 4, 61-625 Poznań","city":"Poznań","postal":"61-625"},{"name":"Pracownia w Poznaniu","address":"ul. Czarna Rola 4, 61-625 Poznań","city":"Poznań","postal":"61-625"},{"name":"Pracownia w Kaliszu","address":"ul. Piwonicka 19, 62-800 Kalisz","city":"Kalisz","postal":"62-800"},{"name":"Pracownia w Koninie","address":"ul. Kard. Stefana Wyszyńskiego 3a, 62-510 Konin","city":"Konin","postal":"62-510"},{"name":"Pracownia w Lesznie","address":"ul. 17 Stycznia 4, 64-100 Leszno","city":"Leszno","postal":"64-100"},{"name":"Pracownia w Pile","address":"ul. Motylewska 5a, 64-920 Piła","city":"Piła","postal":"64-920"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/3cd2bbacda8b6a880fde41e1626aa9d2/AB%20199.pdf","has_en":true,"category_counts":{"water":146,"environment":59,"other":6,"petro":4,"materials":3,"microbiology":1},"category_scores":{"water":97.33,"environment":15.89,"other":0.16,"petro":0.07,"materials":0.04,"microbiology":0},"has_zh":true},"methods":[{"_id":"6a832aeb884ede9a1b2c52f7","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12","PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wylaczeniem pkt. 5.2, 6.2","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2","test_object_zh":"水"},{"_id":"6a832aeb884ede9a1b2c52f8","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) oC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (0,0 – 50,0) oC PN-77/C-04584 Woda Temperatura\nZakres (0,0 – 50,0) oC PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a832aeb884ede9a1b2c52f9","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l O2"},{"name":"Nasycenie tlenem"},{"name":"Zakres","range":"(6 – 150) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 15,0) mg/l O2\nNasycenie tlenem\nZakres (6 – 150) %\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 15,0) mg/l O2\nNasycenie tlenem\nZakres (6 – 150) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 15,0) mg/l O2\nNasycenie tlenem\nZakres (6 – 150) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l O2"},{"name":"Oxygen saturation"},{"name":"Range","range":"(6 – 150) %"}],"search_en":"Water Dissolved oxygen concentration Electrochemical method Range Oxygen saturation Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l O2"},{"name":"氧饱和度"},{"name":"范围","range":"(6 – 150) %"}],"search_zh":"水 溶解氧浓度 电化学法 范围 氧饱和度 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a832aeb884ede9a1b2c52fa","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a832aeb884ede9a1b2c52fb","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a832aeb884ede9a1b2c52fc","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) oC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (0,0 – 50,0) oC PN-77/C-04584 Scieki Temperatura\nZakres (0,0 – 50,0) oC PN-77/C-04584","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a832aeb884ede9a1b2c52fd","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c52fe","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 10000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 10000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c52ff","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 | PN-Z-15011-1:1998","norm_bases":["PN-EN ISO 5667-13:2011","PN-Z-15011-1:1998"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 | PN-Z-15011-1:1998 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 | PN-Z-15011-1:1998","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 | PN-Z-15011-1:1998","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 | PN-Z-15011-1:1998","test_object_zh":"污泥"},{"_id":"6a832aeb884ede9a1b2c5300","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05","methodology":"Pobieranie próbek do badań mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05 Pobieranie próbek do badań mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 Osady sciekowe, Odpady O): kod 19 08 05 Pobieranie probek do badan mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011","categories":["water","environment","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological and parasitological testing","search_en":"Sewage sludge, Waste O): code 19 08 05 Sampling for microbiological and parasitological testing PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge, Waste O): code 19 08 05","methodology_zh":"用于微生物与寄生虫学检验的采样","search_zh":"用于微生物与寄生虫学检验的采样 PN-EN ISO 5667-13:2011"},{"_id":"6a832aeb884ede9a1b2c5301","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5302","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O): kod 17 05 03, 17 05 04, 19 08 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-5:2009 | PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8","norm_bases":["PN-ISO 10381-5:2009","PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O): kod 17 05 03, 17 05 04, 19 08 05 Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-5:2009 | PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8 Odpady O): kod 17 05 03, 17 05 04, 19 08 05 Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-5:2009 | PN-EN ISO 5667-13:2011 z wylaczeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing PN-ISO 10381-5:2009 | PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-ISO 10381-5:2009 | PN-EN ISO 5667-13:2011 z wyłączeniem 6.3.4, 6.3.5, 6.3.7, 6.3.8"},{"_id":"6a832aeb884ede9a1b2c5303","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady","methodology":"Badania interwencyjne (wg Programu DAB-11)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania interwencyjne (wg Programu DAB-11)","reference":"PB-11/CLB wyd. 1 z 25.09.2023 r.","norm_bases":["PB-11/CLB wyd. 1 z 25.09.2023 r."],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wyd. 1 z 25.09.2023 r. Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wyd. 1 z 25.09.2023 r.","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intervention testing (according to Programme DAB-11)","search_en":"Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wyd. 1 z 25.09.2023 r.","test_object_en":"Waste","search_zh":"废物 干预性检验（依据 DAB-11 计划） PB-11/CLB wyd. 1 z 25.09.2023 r.","test_object_zh":"废物","methodology_zh":"干预性检验（依据 DAB-11 计划）"},{"_id":"6a832aeb884ede9a1b2c5304","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25,0 – 130,0) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25,0 – 130,0) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a832aeb884ede9a1b2c5305","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a832aeb884ede9a1b2c5306","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych i linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25,0 – 130,0) dB"}],"search_en":"General environment – noise from roads, railway lines and tramway lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines and tramway lines","parameters_zh":[{"name":"范围","range":"(25,0 – 130,0) dB"}],"search_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声"},{"_id":"6a832aeb884ede9a1b2c5307","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych i linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from roads, railway lines and tramway lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","test_object_en":"General environment – noise from roads, railway lines and tramway lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140, poz. 824) (Dz. U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","test_object_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声"},{"_id":"6a832aeb884ede9a1b2c5308","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25,0 – 130,0) dB"}],"search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level Direct measurement method Range Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级 A 计权最大声级 A 计权暴露声级","parameters_zh":[{"name":"范围","range":"(25,0 – 130,0) dB"}],"search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 A 计权等效声级 A 计权最大声级 A 计权暴露声级 直接测量法 范围 Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a832aeb884ede9a1b2c5309","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a832aeb884ede9a1b2c530a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od lotnisk Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od lotnisk Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25,0 – 130,0) dB"}],"search_en":"General environment – noise from airports A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment – noise from airports","parameters_zh":[{"name":"范围","range":"(25,0 – 130,0) dB"}],"search_zh":"一般环境 — 来自机场的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 — 来自机场的噪声"},{"_id":"6a832aeb884ede9a1b2c530b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od lotnisk Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od lotnisk Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from airports A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H","test_object_en":"General environment – noise from airports","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自机场的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 Nr 140 poz. 824) z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自机场的噪声"},{"_id":"6a832aeb884ede9a1b2c530c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego o częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"1 V/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego o częstotliwości 50 Hz\nZakres 1 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego o częstotliwości 50 Hz\nZakres 1 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego o czestotliwosci 50 Hz\nZakres 1 V/m – 30 kV/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength at 50 Hz frequency","parameters_en":[{"name":"Range","range":"1 V/m – 30 kV/m"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength at 50 Hz frequency Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"范围","range":"1 V/m – 30 kV/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 50 Hz 工频电场强度 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 工频电场强度"},{"_id":"6a832aeb884ede9a1b2c530d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna o częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"1,0 μT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna o częstotliwości 50 Hz\nZakres 1,0 μT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna o częstotliwości 50 Hz\nZakres 1,0 μT – 10 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna o czestotliwosci 50 Hz\nZakres 1,0 μT – 10 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density at 50 Hz frequency","parameters_en":[{"name":"Range","range":"1,0 μT – 10 mT"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density at 50 Hz frequency Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"范围","range":"1,0 μT – 10 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 50 Hz 工频磁感应强度 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 工频磁感应强度"},{"_id":"6a832aeb884ede9a1b2c530e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego o czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength at 50 Hz frequency (calculated)","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength at 50 Hz frequency (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","search_zh":"环境 — 变电站与输电线路周围的电磁场 50 Hz 工频磁场强度（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 工频磁场强度（由计算得出）"},{"_id":"6a832aeb884ede9a1b2c530f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych pomiary szerokopasmowe","methodology":"Natężenie pola elektrycznego: w zakresie częstotliwości od 10 MHz – 60 GHz","parameters":[{"name":"Zakres","range":"0,3 V/m – 300 V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego: w zakresie częstotliwości od 10 MHz – 60 GHz\nZakres 0,3 V/m – 300 V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych pomiary szerokopasmowe Natężenie pola elektrycznego: w zakresie częstotliwości od 10 MHz – 60 GHz\nZakres 0,3 V/m – 300 V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych pomiary szerokopasmowe Natezenie pola elektrycznego: w zakresie czestotliwosci od 10 MHz – 60 GHz\nZakres 0,3 V/m – 300 V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength: in the frequency range from 10 MHz – 60 GHz","parameters_en":[{"name":"Range","range":"0,3 V/m – 300 V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements Electric field strength: in the frequency range from 10 MHz – 60 GHz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements","parameters_zh":[{"name":"范围","range":"0,3 V/m – 300 V/m"}],"search_zh":"直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a832aeb884ede9a1b2c5310","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych pomiary szerokopasmowe","methodology":"Natężenie pola magnetycznego: w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych pomiary szerokopasmowe Natężenie pola magnetycznego: w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych pomiary szerokopasmowe Natezenie pola magnetycznego: w zakresie czestotliwosci od 10 MHz do 60 GHz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength: in the frequency range from 10 MHz to 60 GHz (calculated)","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements Magnetic field strength: in the frequency range from 10 MHz to 60 GHz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations broadband measurements"},{"_id":"6a832aeb884ede9a1b2c5311","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO2, NOx, CO, CO2 i O2","parameters":[{"name":"SO2","range":"( 12– 2860) mg/m3"},{"name":"CO","range":"(7 – 2500) mg/m3"},{"name":"CO2","range":"(0,2 – 18,0) %"},{"name":"NOx","range":"(2 – 925) mg/m3"},{"name":"O2","range":"( 0,4 – 21,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","Metoda chemiluminescencyjna","Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie SO2, NOx, CO, CO2 i O2\nZakres:\nSO2 ( 12– 2860) mg/m3\nCO (7 – 2500) mg/m3\nCO2 (0,2 – 18,0) %\nNOx (2 – 925) mg/m3\nO2 ( 0,4 – 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie SO2, NOx, CO, CO2 i O2\nZakres:\nSO2 ( 12– 2860) mg/m3\nCO (7 – 2500) mg/m3\nCO2 (0,2 – 18,0) %\nNOx (2 – 925) mg/m3\nO2 ( 0,4 – 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie SO2, NOx, CO, CO2 i O2\nZakres:\nSO2 ( 12– 2860) mg/m3\nCO (7 – 2500) mg/m3\nCO2 (0,2 – 18,0) %\nNOx (2 – 925) mg/m3\nO2 ( 0,4 – 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2, NOx, CO, CO2 and O2 concentration","parameters_en":[{"name":"SO2","range":"( 12– 2860) mg/m3"},{"name":"CO","range":"(7 – 2500) mg/m3"},{"name":"CO2","range":"(0,2 – 18,0) %"},{"name":"NOx","range":"(2 – 925) mg/m3"},{"name":"O2","range":"( 0,4 – 21,0) %"}],"search_en":"Waste gases SO2, NOx, CO, CO2 and O2 concentration Non-dispersive infrared spectrometry (NDIR); Chemiluminescence method; Paramagnetic method SO2 CO CO2 NOx O2 PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR); Chemiluminescence method; Paramagnetic method","test_object_en":"Waste gases","search_zh":"废气 SO2 CO CO2 NOx O2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"( 12– 2860) mg/m3"},{"name":"CO","range":"(7 – 2500) mg/m3"},{"name":"CO2","range":"(0,2 – 18,0) %"},{"name":"NOx","range":"(2 – 925) mg/m3"},{"name":"O2","range":"( 0,4 – 21,0) %"}]},{"_id":"6a832aeb884ede9a1b2c5312","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, CO2 (calculated)","search_en":"Waste gases Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, CO2 (calculated) PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a832aeb884ede9a1b2c5313","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a832aeb884ede9a1b2c5314","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"( 0,002– 1,0) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres ( 0,002– 1,0) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres ( 0,002– 1,0) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres ( 0,002– 1,0) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"( 0,002– 1,0) g/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"( 0,002– 1,0) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a832aeb884ede9a1b2c5315","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a832aeb884ede9a1b2c5316","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a832aeb884ede9a1b2c5317","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda aspiracyjna","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda aspiracyjna PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych\nMetoda aspiracyjna PN-EN 13649:2005","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Aspiration method PN-EN 13649:2005","technique_en":"Aspiration method","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物浓度测定采样 抽气法 PN-EN 13649:2005","test_object_zh":"废气","technique_zh":"抽气法","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a832aeb884ede9a1b2c5318","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a832aeb884ede9a1b2c5319","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego/ zelu krzemionkowego/roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of concentrations of organic compounds","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Aspiration method using activated carbon/ silica gel/absorbing solutions PN-Z-04008-4:1999","technique_en":"Aspiration method using activated carbon/ silica gel/absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 有机化合物浓度测定采样 PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a832aeb884ede9a1b2c531a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic compounds (calculated)","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a832aeb884ede9a1b2c531b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,50 – 100) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,50 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016-07"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres (0,50 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 Scieki Stezenie rteci\nZakres (0,50 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,50 – 100) μg/l"}],"search_en":"Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012+Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 100) μg/l"}],"search_zh":"污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012+Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污水"},{"_id":"6a832aeb884ede9a1b2c531c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Azot azotanowy","range":"(0,10 – 100) mg/l"},{"name":"Fluorki","range":"(0,040 – 20) mg/l"},{"name":"Chlorki","range":"(0,40 – 400) mg/l"},{"name":"Siarczany","range":"(0,40 – 400) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzot azotanowy (0,10 – 100) mg/l\nFluorki (0,040 – 20) mg/l\nChlorki (0,40 – 400) mg/l\nSiarczany (0,40 – 400) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nAzot azotanowy (0,10 – 100) mg/l\nFluorki (0,040 – 20) mg/l\nChlorki (0,40 – 400) mg/l\nSiarczany (0,40 – 400) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda, scieki Stezenie anionow\nZakres:\nAzot azotanowy (0,10 – 100) mg/l\nFluorki (0,040 – 20) mg/l\nChlorki (0,40 – 400) mg/l\nSiarczany (0,40 – 400) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrate nitrogen","range":"(0,10 – 100) mg/l"},{"name":"Fluorides","range":"(0,040 – 20) mg/l"},{"name":"Chlorides","range":"(0,40 – 400) mg/l"},{"name":"Sulfates","range":"(0,40 – 400) mg/l"}],"search_en":"Water, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrate nitrogen Fluorides Chlorides Sulfates PN-EN ISO 10304-1:2009 + AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐氮","range":"(0,10 – 100) mg/l"},{"name":"氟化物","range":"(0,040 – 20) mg/l"},{"name":"氯化物","range":"(0,40 – 400) mg/l"},{"name":"硫酸盐","range":"(0,40 – 400) mg/l"}],"search_zh":"水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐氮 氟化物 氯化物 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c531d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,025 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,025 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN ISO 7150-1:2002","norm_bases":["PN ISO 7150-1:2002"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,025 – 10) mg/l\nMetoda spektrofotometryczna PN ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,025 – 10) mg/l\nMetoda spektrofotometryczna PN ISO 7150-1:2002","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,025 – 10) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 10) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c531e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie surfaktantów anionowych (substancji powierzchniowo-czynnych anionowych)","parameters":[{"name":"Zakres","range":"(0,060 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów anionowych (substancji powierzchniowo-czynnych anionowych)\nZakres (0,060 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych (substancji powierzchniowo-czynnych anionowych)\nZakres (0,060 – 50) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, scieki Stezenie surfaktantow anionowych (substancji powierzchniowo-czynnych anionowych)\nZakres (0,060 – 50) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic surfactant concentration (anionic surface-active agents)","parameters_en":[{"name":"Range","range":"(0,060 – 50) mg/l"}],"search_en":"Water, wastewater Anionic surfactant concentration (anionic surface-active agents) Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,060 – 50) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c531f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie arsenu","parameters":[{"name":"Zakres","range":"(5,0 – 100) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie arsenu\nZakres (5,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie arsenu\nZakres (5,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, scieki Stezenie arsenu\nZakres (5,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic concentration","parameters_en":[{"name":"Range","range":"(5,0 – 100) μg/l"}],"search_en":"Water, wastewater Arsenic concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 100) μg/l"}],"search_zh":"水、废水 砷浓度 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、废水","methodology_zh":"砷浓度"},{"_id":"6a832aeb884ede9a1b2c5320","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Bar","range":"(0,0050 – 20) mg/l"},{"name":"Bor","range":"(0,010 – 20) mg/l"},{"name":"Chrom","range":"(0,0050 – 20) mg/l"},{"name":"Cynk","range":"(0,020 – 20) mg/l"},{"name":"Fosfor","range":"(0,010-100) mg/l"},{"name":"Glin","range":"(0,050 – 20) mg/l"},{"name":"Kadm","range":"(0,0050 – 20) mg/l"},{"name":"Kobalt","range":"(0,010 – 20) mg/l"},{"name":"Mangan","range":"(0,010 – 20) mg/l"},{"name":"Miedź","range":"(0,0050 – 20) mg/l"},{"name":"Molibden","range":"(0,012 – 20) mg/l"},{"name":"Nikiel","range":"(0,020 – 20) mg/l"},{"name":"Ołów","range":"(0,020 – 20) mg/l"},{"name":"Tytan","range":"(0,010 – 20) mg/l"},{"name":"Wanad","range":"(0,0050 – 20) mg/l"},{"name":"Żelazo","range":"(0,020 – 20) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nBar (0,0050 – 20) mg/l\nBor (0,010 – 20) mg/l\nChrom (0,0050 – 20) mg/l\nCynk (0,020 – 20) mg/l\nFosfor (0,010-100) mg/l\nGlin (0,050 – 20) mg/l\nKadm (0,0050 – 20) mg/l\nKobalt (0,010 – 20) mg/l\nMangan (0,010 – 20) mg/l\nMiedź (0,0050 – 20) mg/l\nMolibden (0,012 – 20) mg/l\nNikiel (0,020 – 20) mg/l\nOłów (0,020 – 20) mg/l\nTytan (0,010 – 20) mg/l\nWanad (0,0050 – 20) mg/l\nŻelazo (0,020 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nBar (0,0050 – 20) mg/l\nBor (0,010 – 20) mg/l\nChrom (0,0050 – 20) mg/l\nCynk (0,020 – 20) mg/l\nFosfor (0,010-100) mg/l\nGlin (0,050 – 20) mg/l\nKadm (0,0050 – 20) mg/l\nKobalt (0,010 – 20) mg/l\nMangan (0,010 – 20) mg/l\nMiedź (0,0050 – 20) mg/l\nMolibden (0,012 – 20) mg/l\nNikiel (0,020 – 20) mg/l\nOłów (0,020 – 20) mg/l\nTytan (0,010 – 20) mg/l\nWanad (0,0050 – 20) mg/l\nŻelazo (0,020 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali\nZakres:\nBar (0,0050 – 20) mg/l\nBor (0,010 – 20) mg/l\nChrom (0,0050 – 20) mg/l\nCynk (0,020 – 20) mg/l\nFosfor (0,010-100) mg/l\nGlin (0,050 – 20) mg/l\nKadm (0,0050 – 20) mg/l\nKobalt (0,010 – 20) mg/l\nMangan (0,010 – 20) mg/l\nMiedz (0,0050 – 20) mg/l\nMolibden (0,012 – 20) mg/l\nNikiel (0,020 – 20) mg/l\nOlow (0,020 – 20) mg/l\nTytan (0,010 – 20) mg/l\nWanad (0,0050 – 20) mg/l\nZelazo (0,020 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Barium","range":"(0,0050 – 20) mg/l"},{"name":"Boron","range":"(0,010 – 20) mg/l"},{"name":"Chromium","range":"(0,0050 – 20) mg/l"},{"name":"Zinc","range":"(0,020 – 20) mg/l"},{"name":"Phosphorus","range":"(0,010-100) mg/l"},{"name":"Aluminium","range":"(0,050 – 20) mg/l"},{"name":"Cadmium","range":"(0,0050 – 20) mg/l"},{"name":"Cobalt","range":"(0,010 – 20) mg/l"},{"name":"Manganese","range":"(0,010 – 20) mg/l"},{"name":"Copper","range":"(0,0050 – 20) mg/l"},{"name":"Molybdenum","range":"(0,012 – 20) mg/l"},{"name":"Nickel","range":"(0,020 – 20) mg/l"},{"name":"Lead","range":"(0,020 – 20) mg/l"},{"name":"Titanium","range":"(0,010 – 20) mg/l"},{"name":"Vanadium","range":"(0,0050 – 20) mg/l"},{"name":"Iron","range":"(0,020 – 20) mg/l"}],"search_en":"Water, wastewater Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Barium Boron Chromium Zinc Phosphorus Aluminium Cadmium Cobalt Manganese Copper Molybdenum Nickel Lead Titanium Vanadium Iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"钡","range":"(0,0050 – 20) mg/l"},{"name":"硼","range":"(0,010 – 20) mg/l"},{"name":"铬","range":"(0,0050 – 20) mg/l"},{"name":"锌","range":"(0,020 – 20) mg/l"},{"name":"磷","range":"(0,010-100) mg/l"},{"name":"铝","range":"(0,050 – 20) mg/l"},{"name":"镉","range":"(0,0050 – 20) mg/l"},{"name":"钴","range":"(0,010 – 20) mg/l"},{"name":"锰","range":"(0,010 – 20) mg/l"},{"name":"铜","range":"(0,0050 – 20) mg/l"},{"name":"钼","range":"(0,012 – 20) mg/l"},{"name":"镍","range":"(0,020 – 20) mg/l"},{"name":"铅","range":"(0,020 – 20) mg/l"},{"name":"钛","range":"(0,010 – 20) mg/l"},{"name":"钒","range":"(0,0050 – 20) mg/l"},{"name":"铁","range":"(0,020 – 20) mg/l"}],"search_zh":"水、废水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 钡 硼 铬 锌 磷 铝 镉 钴 锰 铜 钼 镍 铅 钛 钒 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5321","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(200 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (200 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03","norm_bases":["PN-EN 15216: 2022-03"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (200 – 10000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (200 – 10000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(200 – 10000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216: 2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(200 – 10000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216: 2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c5322","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5323","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 100) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/l O2"}],"search_en":"Water, wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/l O2"}],"search_zh":"水、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5324","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5, BZT2+5"},{"name":"Zakres","range":"(2 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (2 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (2 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (2 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5, BOD2+5"},{"name":"Range","range":"(2 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5, BOD2+5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BOD5、BOD2+5"},{"name":"范围","range":"(2 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BOD5、BOD2+5 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5325","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5, BZT2+5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5, BZT2+5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5, BOD2+5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5, BOD2+5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BOD5、BOD2+5"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BOD5、BOD2+5 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5326","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,015 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,015 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,015 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,015 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,015 – 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 7 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5327","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,010 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,010 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,010 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,010 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,010 – 100) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 100) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a832aeb884ede9a1b2c5328","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0017 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0017 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0017 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0017 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0017 – 10) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0017 – 10) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5329","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,61 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,61 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,61 – 300) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,61 – 300) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,61 – 300) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,61 – 300) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c532a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,30 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,30 – 400) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,30 – 400) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,30 – 400) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 – 400) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,30 – 400) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c532b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 – 10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(30 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(30 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c532c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,00 – 100) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,00 – 100) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,00 – 100) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,00 – 100) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(7,00 – 100) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(7,00 – 100) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c532d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wyd.1 z 16.01.2026 r.","norm_bases":["PB-26/CLB wyd.1 z 16.01.2026 r."],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wyd.1 z 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wyd.1 z 16.01.2026 r.","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c532e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba, osady ściekowe, odpady o): kod 19 08 05","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,10 – 33) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,10 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2 | PN-EN 16173:2012","norm_bases":["PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2","PN-EN 16173:2012"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Gleba, osady ściekowe, odpady o): kod 19 08 05 Zawartość rtęci\nZakres (0,10 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2 | PN-EN 16173:2012 Gleba, osady sciekowe, odpady o): kod 19 08 05 Zawartosc rteci\nZakres (0,10 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-ISO 16772:2009 z wylaczeniem pkt. 7.1, 7.2 | PN-EN 16173:2012","categories":["environment","water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,10 – 33) mg/kg"}],"search_en":"Soil, sewage sludge, waste o): code 19 08 05 Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2 | PN-EN 16173:2012","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Soil, sewage sludge, waste o): code 19 08 05","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,10 – 33) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-ISO 16772:2009 z wyłączeniem pkt. 7.1, 7.2 | PN-EN 16173:2012","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832aeb884ede9a1b2c532f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba, osady ściekowe, odpady o): kod 19 08 05","methodology":"Zawartość metali:","parameters":[{"name":"Chrom","range":"(1,0 – 1600) mg/kg"},{"name":"Kadm","range":"(1,0 – 1600) mg/kg"},{"name":"Miedź","range":"(1,0 – 1600) mg/kg"},{"name":"Nikiel","range":"(4,0 – 1600) mg/kg"},{"name":"Ołów","range":"(4,0 – 1600) mg/kg"},{"name":"Cynk","range":"(4,0 – 8000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali:\nZakres:\nChrom (1,0 – 1600) mg/kg\nKadm (1,0 – 1600) mg/kg\nMiedź (1,0 – 1600) mg/kg\nNikiel (4,0 – 1600) mg/kg\nOłów (4,0 – 1600) mg/kg\nCynk (4,0 – 8000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012","norm_bases":["PN-EN ISO 11885:2009 z wyłączeniem pkt. 9","PN-EN 16173:2012"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Gleba, osady ściekowe, odpady o): kod 19 08 05 Zawartość metali:\nZakres:\nChrom (1,0 – 1600) mg/kg\nKadm (1,0 – 1600) mg/kg\nMiedź (1,0 – 1600) mg/kg\nNikiel (4,0 – 1600) mg/kg\nOłów (4,0 – 1600) mg/kg\nCynk (4,0 – 8000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012 Gleba, osady sciekowe, odpady o): kod 19 08 05 Zawartosc metali:\nZakres:\nChrom (1,0 – 1600) mg/kg\nKadm (1,0 – 1600) mg/kg\nMiedz (1,0 – 1600) mg/kg\nNikiel (4,0 – 1600) mg/kg\nOlow (4,0 – 1600) mg/kg\nCynk (4,0 – 8000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 z wylaczeniem pkt. 9 | PN-EN 16173:2012","categories":["materials","environment","water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content:","parameters_en":[{"name":"Chromium","range":"(1,0 – 1600) mg/kg"},{"name":"Cadmium","range":"(1,0 – 1600) mg/kg"},{"name":"Copper","range":"(1,0 – 1600) mg/kg"},{"name":"Nickel","range":"(4,0 – 1600) mg/kg"},{"name":"Lead","range":"(4,0 – 1600) mg/kg"},{"name":"Zinc","range":"(4,0 – 8000) mg/kg"}],"search_en":"Soil, sewage sludge, waste o): code 19 08 05 Metal content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Chromium Cadmium Copper Nickel Lead Zinc PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil, sewage sludge, waste o): code 19 08 05","parameters_zh":[{"name":"铬","range":"(1,0 – 1600) mg/kg"},{"name":"镉","range":"(1,0 – 1600) mg/kg"},{"name":"铜","range":"(1,0 – 1600) mg/kg"},{"name":"镍","range":"(4,0 – 1600) mg/kg"},{"name":"铅","range":"(4,0 – 1600) mg/kg"},{"name":"锌","range":"(4,0 – 8000) mg/kg"}],"search_zh":"金属含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 镉 铜 镍 铅 锌 PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量："},{"_id":"6a832aeb884ede9a1b2c5330","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(30,0 – 99,0) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(1,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (30,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 70,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (30,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 70,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Gleba Sucha masa\nZakres:\nZakres (30,0 – 99,0) %\nZawartosc wody\nZakres (1,0 – 70,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(30,0 – 99,0) %"},{"name":"Water content"},{"name":"Range","range":"(1,0 – 70,0) %"}],"search_en":"Soil Dry matter Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(30,0 – 99,0) %"},{"name":"水分含量"},{"name":"范围","range":"(1,0 – 70,0) %"}],"search_zh":"土壤 干物质 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5331","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w H20","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w H20\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w H20\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H20","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"Soil pH - in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5332","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(20 – 12900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (20 – 12900) μS/cm\nMetoda konduktometryczna","reference":"PN-ISO 11265+AC1:1997","norm_bases":["PN-ISO 11265+AC1:1997"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Przewodność elektryczna właściwa\nZakres (20 – 12900) μS/cm\nMetoda konduktometryczna PN-ISO 11265+AC1:1997 Gleba Przewodnosc elektryczna wlasciwa\nZakres (20 – 12900) μS/cm\nMetoda konduktometryczna PN-ISO 11265+AC1:1997","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(20 – 12900) μS/cm"}],"search_en":"Soil Electrical conductivity Conductometric method Range PN-ISO 11265+AC1:1997","technique_en":"Conductometric method","test_object_en":"Soil","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(20 – 12900) μS/cm"}],"search_zh":"土壤 电导率 电导法 范围 PN-ISO 11265+AC1:1997","technique_zh":"电导法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5333","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość arsenu:","parameters":[{"name":"Zakres","range":"(4,0 – 1600) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość arsenu:\nZakres (4,0 – 1600) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012","norm_bases":["PN-EN ISO 11885:2009 z wyłączeniem pkt. 9","PN-EN 16173:2012"],"lab_section":"Pracownia w Poznaniu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość arsenu:\nZakres (4,0 – 1600) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012 Gleba Zawartosc arsenu:\nZakres (4,0 – 1600) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 z wylaczeniem pkt. 9 | PN-EN 16173:2012","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic content:","parameters_en":[{"name":"Range","range":"(4,0 – 1600) mg/kg"}],"search_en":"Soil Arsenic content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(4,0 – 1600) mg/kg"}],"search_zh":"土壤 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009 z wyłączeniem pkt. 9 | PN-EN 16173:2012","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5334","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 50) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 50) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,50 – 50) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,50 – 50) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 50) mg/l O2"}],"search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 50) mg/l O2"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a832aeb884ede9a1b2c5335","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration (TOC) Infrared spectrometry method (IR) Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 总有机碳浓度（TOC） 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、废水","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"红外光谱法（IR）"},{"_id":"6a832aeb884ede9a1b2c5336","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 8,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 – 8,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,010 – 8,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,010 – 8,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 8,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 8,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5337","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,001 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,001 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 10) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 10) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5338","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"},{"name":"Zakres","range":"(0,20 – 5,0) mg/l"}],"technique":"Metoda miareczkowa; Metoda spektrofotometryczna","techniques":["Metoda miareczkowa","Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres:\nZakres (2,0 – 500) mg/l\nZakres (0,20 – 5,0) mg/l\nMetoda miareczkowa; Metoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres:\nZakres (2,0 – 500) mg/l\nZakres (0,20 – 5,0) mg/l\nMetoda miareczkowa; Metoda spektrofotometryczna PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres:\nZakres (2,0 – 500) mg/l\nZakres (0,20 – 5,0) mg/l\nMetoda miareczkowa; Metoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"},{"name":"Range","range":"(0,20 – 5,0) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method; Spectrophotometric method Range Range PN-EN 25663:2001","technique_en":"Titrimetric method; Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"},{"name":"范围","range":"(0,20 – 5,0) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法；分光光度法 范围 范围 PN-EN 25663:2001","test_object_zh":"水、废水","technique_zh":"滴定法；分光光度法"},{"_id":"6a832aeb884ede9a1b2c5339","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,010 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,010 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,010 – 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c533a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"P","range":"(0,005 – 5,00) mg/l"},{"name":"PO4","range":"(0,015 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres:\nP (0,005 – 5,00) mg/l\nPO4 (0,015 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres:\nP (0,005 – 5,00) mg/l\nPO4 (0,015 – 15,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres:\nP (0,005 – 5,00) mg/l\nPO4 (0,015 – 15,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"P","range":"(0,005 – 5,00) mg/l"},{"name":"PO4","range":"(0,015 – 15,0) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method P PO4 PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","search_zh":"水、废水 正磷酸盐浓度 分光光度法 P PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度","parameters_zh":[{"name":"P","range":"(0,005 – 5,00) mg/l"},{"name":"PO4","range":"(0,015 – 15,0) mg/l"}]},{"_id":"6a832aeb884ede9a1b2c533b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573-01","norm_bases":["PN-86/C-04573-01"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-86/C-04573-01 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-86/C-04573-01","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573-01","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573-01","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a832aeb884ede9a1b2c533c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03","norm_bases":["PN-EN 15216: 2022-03"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 5000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216: 2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 5000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216: 2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c533d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(4,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (4,0 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (4,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (4,0 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(4,0 – 10000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(4,0 – 10000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c533e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c533f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5, BOD2+5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5, BOD2+5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 － BOD5、BOD2+5 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"生化需氧量 － BOD5、BOD2+5"},{"_id":"6a832aeb884ede9a1b2c5340","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5, BOD2+5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5, BOD2+5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 － BOD5、BOD2+5 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"生化需氧量 － BOD5、BOD2+5"},{"_id":"6a832aeb884ede9a1b2c5341","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wyd.1 z 16.01.2026 r.","norm_bases":["PB-26/CLB wyd.1 z 16.01.2026 r."],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wyd.1 z 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wyd.1 z 16.01.2026 r.","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5342","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c5343","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,0025 – 200) g/kg"},{"name":"Zakres","range":"(0,00025 – 20) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,0025 – 200) g/kg\nZakres (0,00025 – 20) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (0,0025 – 200) g/kg\nZakres (0,00025 – 20) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (0,0025 – 200) g/kg\nZakres (0,00025 – 20) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,0025 – 200) g/kg"},{"name":"Range","range":"(0,00025 – 20) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,0025 – 200) g/kg"},{"name":"范围","range":"(0,00025 – 20) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 范围 PN-EN 14672:2006","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a832aeb884ede9a1b2c5344","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(10,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (10,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(10,0 – 90,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0) %"}],"search_zh":"污泥 干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a832aeb884ede9a1b2c5345","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(5,0 – 80,0) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(20,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (5,0 – 80,0) %\nZawartość wody\nZakres (20,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres:\nZakres (5,0 – 80,0) %\nZawartość wody\nZakres (20,0 – 95,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Osady sciekowe Sucha pozostalosc\nZakres:\nZakres (5,0 – 80,0) %\nZawartosc wody\nZakres (20,0 – 95,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(5,0 – 80,0) %"},{"name":"Water content"},{"name":"Range","range":"(20,0 – 95,0) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 80,0) %"},{"name":"水分含量"},{"name":"范围","range":"(20,0 – 95,0) %"}],"search_zh":"污泥 干残渣 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣"},{"_id":"6a832aeb884ede9a1b2c5346","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 100) g/kg"},{"name":"Zakres","range":"(0,005 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres:\nZakres (0,05 – 100) g/kg\nZakres (0,005 – 10) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres:\nZakres (0,05 – 100) g/kg\nZakres (0,005 – 10) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres:\nZakres (0,05 – 100) g/kg\nZakres (0,005 – 10) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,05 – 100) g/kg"},{"name":"Range","range":"(0,005 – 10) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,05 – 100) g/kg"},{"name":"范围","range":"(0,005 – 10) %"}],"search_zh":"污泥 氨氮含量 滴定法 范围 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a832aeb884ede9a1b2c5347","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,15 –100) g/kg"},{"name":"Zakres","range":"(0,015 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (0,15 –100) g/kg\nZakres (0,015 – 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres:\nZakres (0,15 –100) g/kg\nZakres (0,015 – 10) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres:\nZakres (0,15 –100) g/kg\nZakres (0,015 – 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,15 –100) g/kg"},{"name":"Range","range":"(0,015 – 10) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,15 –100) g/kg"},{"name":"范围","range":"(0,015 – 10) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a832aeb884ede9a1b2c5348","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH - w H20","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH - w H20\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w H20\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H20","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Sewage sludge pH - in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"污泥 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a832aeb884ede9a1b2c5349","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(20,0 – 99,0) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(1,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (20,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (20,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 80,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Gleba Sucha masa\nZakres:\nZakres (20,0 – 99,0) %\nZawartosc wody\nZakres (1,0 – 80,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(20,0 – 99,0) %"},{"name":"Water content"},{"name":"Range","range":"(1,0 – 80,0) %"}],"search_en":"Soil Dry matter Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(20,0 – 99,0) %"},{"name":"水分含量"},{"name":"范围","range":"(1,0 – 80,0) %"}],"search_zh":"土壤 干物质 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c534a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w H20, pH - w KCl","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20, pH - w KCl\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w H20, pH - w KCl\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w H20, pH - w KCl\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H20, pH - in KCl","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Soil pH - in H20, pH - in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c534b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05 19 12 12","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(5000 – 30000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (5000 – 30000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 19 12 12 Ciepło spalania\nZakres (5000 – 30000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Odpady O) kod: 19 08 05 19 12 12 Cieplo spalania\nZakres (5000 – 30000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(5000 – 30000) kJ/kg"}],"search_en":"Gross calorific value Calorimetric method Range PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(5000 – 30000) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 PN-EN ISO 18125:2017-07","technique_zh":"量热法"},{"_id":"6a832aeb884ede9a1b2c534c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(5000 – 30000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (5000 – 30000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Pracownia w Kaliszu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania\nZakres (5000 – 30000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania\nZakres (5000 – 30000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(5000 – 30000) kJ/kg"}],"search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Calorimetric method Range PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(5000 – 30000) kJ/kg"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 高位发热量 量热法 范围 PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832aeb884ede9a1b2c534d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(0,10 – 50) mg/l"},{"name":"Chlorki","range":"(1,0 – 100) mg/l"},{"name":"Fluorki","range":"(0,10 – 2,0) mg/l"},{"name":"Siarczany","range":"(1,0 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (0,10 – 50) mg/l\nChlorki (1,0 – 100) mg/l\nFluorki (0,10 – 2,0) mg/l\nSiarczany (1,0 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów\nZakres:\nAzotany (0,10 – 50) mg/l\nChlorki (1,0 – 100) mg/l\nFluorki (0,10 – 2,0) mg/l\nSiarczany (1,0 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda Stezenie anionow\nZakres:\nAzotany (0,10 – 50) mg/l\nChlorki (1,0 – 100) mg/l\nFluorki (0,10 – 2,0) mg/l\nSiarczany (1,0 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(0,10 – 50) mg/l"},{"name":"Chlorides","range":"(1,0 – 100) mg/l"},{"name":"Fluorides","range":"(0,10 – 2,0) mg/l"},{"name":"Sulfates","range":"(1,0 – 100) mg/l"}],"search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates Chlorides Fluorides Sulfates PN-EN ISO 10304-1:2009 + AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(0,10 – 50) mg/l"},{"name":"氯化物","range":"(1,0 – 100) mg/l"},{"name":"氟化物","range":"(0,10 – 2,0) mg/l"},{"name":"硫酸盐","range":"(1,0 – 100) mg/l"}],"search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a832aeb884ede9a1b2c534e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009 + AC:2012 Woda Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 + AC:2012","test_object_en":"Water","search_zh":"水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009 + AC:2012","test_object_zh":"水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a832aeb884ede9a1b2c534f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Acenaften","range":"(0,0003 – 0,10) μg/l"},{"name":"Antracen","range":"(0,001 – 0,10) μg/l"},{"name":"Benzo-a-antracen","range":"(0,003 – 0,10) μg/l"},{"name":"Benzo-b-fluoranten","range":"(0,0006 – 0,10) μg/l"},{"name":"Benzo-k-fluoranten","range":"(0,0006 – 0,10) μg/l"},{"name":"Benzo-g,h,i-perylen","range":"(0,0005 – 0,10) μg/l"},{"name":"Benzo-a-piren","range":"(0,00005 – 0,10) μg/l"},{"name":"Chryzen","range":"(0,004 – 0,10) μg/l"},{"name":"Dibenzo(a,h)antracen","range":"(0,002 – 0,10) μg/l"},{"name":"Fenantren","range":"(0,0012 – 0,10) μg/l"},{"name":"Fluoranten","range":"(0,0018 – 0,10) μg/l"},{"name":"Fluoren","range":"(0,0006 – 0,10) μg/l"},{"name":"Indeno(1,2,3-c,d)piren","range":"(0,0005 – 0,10) μg/l"},{"name":"Naftalen","range":"(0,0033 – 0,10) μg/l"},{"name":"Piren","range":"(0,0085 – 0,10) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD).","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)."],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAcenaften (0,0003 – 0,10) μg/l\nAntracen (0,001 – 0,10) μg/l\nBenzo-a-antracen (0,003 – 0,10) μg/l\nBenzo-b-fluoranten (0,0006 – 0,10) μg/l\nBenzo-k-fluoranten (0,0006 – 0,10) μg/l\nBenzo-g,h,i-perylen (0,0005 – 0,10) μg/l\nBenzo-a-piren (0,00005 – 0,10) μg/l\nChryzen (0,004 – 0,10) μg/l\nDibenzo(a,h)antracen (0,002 – 0,10) μg/l\nFenantren (0,0012 – 0,10) μg/l\nFluoranten (0,0018 – 0,10) μg/l\nFluoren (0,0006 – 0,10) μg/l\nIndeno(1,2,3-c,d)piren (0,0005 – 0,10) μg/l\nNaftalen (0,0033 – 0,10) μg/l\nPiren (0,0085 – 0,10) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD).","reference":"PN-EN ISO 17993:2005 | Benzo-g,h,i-perylen","norm_bases":["PN-EN ISO 17993:2005","Benzo-g,h,i-perylen"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAcenaften (0,0003 – 0,10) μg/l\nAntracen (0,001 – 0,10) μg/l\nBenzo-a-antracen (0,003 – 0,10) μg/l\nBenzo-b-fluoranten (0,0006 – 0,10) μg/l\nBenzo-k-fluoranten (0,0006 – 0,10) μg/l\nBenzo-g,h,i-perylen (0,0005 – 0,10) μg/l\nBenzo-a-piren (0,00005 – 0,10) μg/l\nChryzen (0,004 – 0,10) μg/l\nDibenzo(a,h)antracen (0,002 – 0,10) μg/l\nFenantren (0,0012 – 0,10) μg/l\nFluoranten (0,0018 – 0,10) μg/l\nFluoren (0,0006 – 0,10) μg/l\nIndeno(1,2,3-c,d)piren (0,0005 – 0,10) μg/l\nNaftalen (0,0033 – 0,10) μg/l\nPiren (0,0085 – 0,10) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD). PN-EN ISO 17993:2005 | Benzo-g,h,i-perylen Woda Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nAcenaften (0,0003 – 0,10) μg/l\nAntracen (0,001 – 0,10) μg/l\nBenzo-a-antracen (0,003 – 0,10) μg/l\nBenzo-b-fluoranten (0,0006 – 0,10) μg/l\nBenzo-k-fluoranten (0,0006 – 0,10) μg/l\nBenzo-g,h,i-perylen (0,0005 – 0,10) μg/l\nBenzo-a-piren (0,00005 – 0,10) μg/l\nChryzen (0,004 – 0,10) μg/l\nDibenzo(a,h)antracen (0,002 – 0,10) μg/l\nFenantren (0,0012 – 0,10) μg/l\nFluoranten (0,0018 – 0,10) μg/l\nFluoren (0,0006 – 0,10) μg/l\nIndeno(1,2,3-c,d)piren (0,0005 – 0,10) μg/l\nNaftalen (0,0033 – 0,10) μg/l\nPiren (0,0085 – 0,10) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD). PN-EN ISO 17993:2005 | Benzo-g,h,i-perylen","categories":["water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"Acenaphthene","range":"(0,0003 – 0,10) μg/l"},{"name":"Anthracene","range":"(0,001 – 0,10) μg/l"},{"name":"Benzo-a-anthracene","range":"(0,003 – 0,10) μg/l"},{"name":"Benzo-b-fluoranthene","range":"(0,0006 – 0,10) μg/l"},{"name":"Benzo-k-fluoranthene","range":"(0,0006 – 0,10) μg/l"},{"name":"Benzo-g,h,i-perylene","range":"(0,0005 – 0,10) μg/l"},{"name":"Benzo-a-pyrene","range":"(0,00005 – 0,10) μg/l"},{"name":"Chrysene","range":"(0,004 – 0,10) μg/l"},{"name":"Dibenzo(a,h)anthracene","range":"(0,002 – 0,10) μg/l"},{"name":"Phenanthrene","range":"(0,0012 – 0,10) μg/l"},{"name":"Fluoranthene","range":"(0,0018 – 0,10) μg/l"},{"name":"Fluorene","range":"(0,0006 – 0,10) μg/l"},{"name":"Indeno(1,2,3-c,d)piren","range":"(0,0005 – 0,10) μg/l"},{"name":"Naphthalene","range":"(0,0033 – 0,10) μg/l"},{"name":"Pyrene","range":"(0,0085 – 0,10) μg/l"}],"search_en":"Water Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD). Acenaphthene Anthracene Benzo-a-anthracene Benzo-b-fluoranthene Benzo-k-fluoranthene Benzo-g,h,i-perylene Benzo-a-pyrene Chrysene Dibenzo(a,h)anthracene Phenanthrene Fluoranthene Fluorene Naphthalene Pyrene PN-EN ISO 17993:2005 | Benzo-g,h,i-perylen","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD).","test_object_en":"Water","search_zh":"水 多环芳烃（PAHs）浓度 苊 蒽 苯并-a-蒽 苯并-b-荧蒽 苯并-k-荧蒽 苯并-a-芘 䓛 二苯并(a,h)蒽 菲 荧蒽 芴 萘 芘 PN-EN ISO 17993:2005 | Benzo-g,h,i-perylen","test_object_zh":"水","methodology_zh":"多环芳烃（PAHs）浓度","parameters_zh":[{"name":"苊","range":"(0,0003 – 0,10) μg/l"},{"name":"蒽","range":"(0,001 – 0,10) μg/l"},{"name":"苯并-a-蒽","range":"(0,003 – 0,10) μg/l"},{"name":"苯并-b-荧蒽","range":"(0,0006 – 0,10) μg/l"},{"name":"苯并-k-荧蒽","range":"(0,0006 – 0,10) μg/l"},{"name":"Benzo-g,h,i-perylen","range":"(0,0005 – 0,10) μg/l"},{"name":"苯并-a-芘","range":"(0,00005 – 0,10) μg/l"},{"name":"䓛","range":"(0,004 – 0,10) μg/l"},{"name":"二苯并(a,h)蒽","range":"(0,002 – 0,10) μg/l"},{"name":"菲","range":"(0,0012 – 0,10) μg/l"},{"name":"荧蒽","range":"(0,0018 – 0,10) μg/l"},{"name":"芴","range":"(0,0006 – 0,10) μg/l"},{"name":"Indeno(1,2,3-c,d)piren","range":"(0,0005 – 0,10) μg/l"},{"name":"萘","range":"(0,0033 – 0,10) μg/l"},{"name":"芘","range":"(0,0085 – 0,10) μg/l"}]},{"_id":"6a832aeb884ede9a1b2c5350","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Suma wybranych WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wybranych WWA (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Suma wybranych WWA (z obliczeń) PN-EN ISO 17993:2005 Woda Suma wybranych WWA (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of selected PAH (calculated)","search_en":"Water Sum of selected PAH (calculated) PN-EN ISO 17993:2005","test_object_en":"Water","search_zh":"水 选定多环芳烃总量（由计算得出） PN-EN ISO 17993:2005","test_object_zh":"水","methodology_zh":"选定多环芳烃总量（由计算得出）"},{"_id":"6a832aeb884ede9a1b2c5351","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(0,10 – 100) mg/l"},{"name":"Chlorki","range":"(1,0 – 1000) mg/l"},{"name":"Siarczany","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (0,10 – 100) mg/l\nChlorki (1,0 – 1000) mg/l\nSiarczany (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów\nZakres:\nAzotany (0,10 – 100) mg/l\nChlorki (1,0 – 1000) mg/l\nSiarczany (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Scieki Stezenie anionow\nZakres:\nAzotany (0,10 – 100) mg/l\nChlorki (1,0 – 1000) mg/l\nSiarczany (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(0,10 – 100) mg/l"},{"name":"Chlorides","range":"(1,0 – 1000) mg/l"},{"name":"Sulfates","range":"(1,0 – 1000) mg/l"}],"search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates Chlorides Sulfates PN-EN ISO 10304-1:2009 + AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(0,10 – 100) mg/l"},{"name":"氯化物","range":"(1,0 – 1000) mg/l"},{"name":"硫酸盐","range":"(1,0 – 1000) mg/l"}],"search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氯化物 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水"},{"_id":"6a832aeb884ede9a1b2c5352","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009 + AC:2012 Scieki Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 + AC:2012","test_object_en":"Wastewater","search_zh":"污水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009 + AC:2012","test_object_zh":"污水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a832aeb884ede9a1b2c5353","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Acenaften","range":"(0,0003 – 4,0) μg/l"},{"name":"Antracen","range":"(0,001 – 0,08) μg/l"},{"name":"Benzo-a-antracen","range":"(0,003 – 0,20) μg/l"},{"name":"Benzo-b-fluoranten","range":"(0,004 – 0,08) μg/l"},{"name":"Benzo-k-fluoranten","range":"(0,002 – 0,08) μg/l"},{"name":"Benzo-g, h, i-perylen","range":"(0,0005 – 0,32)μg/l"},{"name":"Benzo-a-piren","range":"(0,002 – 0,20) μg/l"},{"name":"Chryzen","range":"(0,005 – 0,20) μg/l"},{"name":"Dibenzo(a,h)antracen","range":"(0,002 – 0,80) μg/l"},{"name":"Fenantren","range":"(0,002 – 0,16) μg/l"},{"name":"Fluoranten","range":"(0,004 – 0,20) μg/l"},{"name":"Fluoren","range":"(0,0006 – 0,40) μg/l"},{"name":"Indeno(1,2,3-c,d)piren","range":"(0,0005 – 0,20) μg/l"},{"name":"Naftalen","range":"(0,004 – 2,0) μg/l"},{"name":"Piren","range":"(0,009 – 0,40) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAcenaften (0,0003 – 4,0) μg/l\nAntracen (0,001 – 0,08) μg/l\nBenzo-a-antracen (0,003 – 0,20) μg/l\nBenzo-b-fluoranten (0,004 – 0,08) μg/l\nBenzo-k-fluoranten (0,002 – 0,08) μg/l\nBenzo-g, h, i-perylen (0,0005 – 0,32)μg/l\nBenzo-a-piren (0,002 – 0,20) μg/l\nChryzen (0,005 – 0,20) μg/l\nDibenzo(a,h)antracen (0,002 – 0,80) μg/l\nFenantren (0,002 – 0,16) μg/l\nFluoranten (0,004 – 0,20) μg/l\nFluoren (0,0006 – 0,40) μg/l\nIndeno(1,2,3-c,d)piren (0,0005 – 0,20) μg/l\nNaftalen (0,004 – 2,0) μg/l\nPiren (0,009 – 0,40) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-08/PO wyd. 01 z 16.06.2020 r.","norm_bases":["PB-08/PO wyd. 01 z 16.06.2020 r."],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAcenaften (0,0003 – 4,0) μg/l\nAntracen (0,001 – 0,08) μg/l\nBenzo-a-antracen (0,003 – 0,20) μg/l\nBenzo-b-fluoranten (0,004 – 0,08) μg/l\nBenzo-k-fluoranten (0,002 – 0,08) μg/l\nBenzo-g, h, i-perylen (0,0005 – 0,32)μg/l\nBenzo-a-piren (0,002 – 0,20) μg/l\nChryzen (0,005 – 0,20) μg/l\nDibenzo(a,h)antracen (0,002 – 0,80) μg/l\nFenantren (0,002 – 0,16) μg/l\nFluoranten (0,004 – 0,20) μg/l\nFluoren (0,0006 – 0,40) μg/l\nIndeno(1,2,3-c,d)piren (0,0005 – 0,20) μg/l\nNaftalen (0,004 – 2,0) μg/l\nPiren (0,009 – 0,40) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-08/PO wyd. 01 z 16.06.2020 r. Woda, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nAcenaften (0,0003 – 4,0) μg/l\nAntracen (0,001 – 0,08) μg/l\nBenzo-a-antracen (0,003 – 0,20) μg/l\nBenzo-b-fluoranten (0,004 – 0,08) μg/l\nBenzo-k-fluoranten (0,002 – 0,08) μg/l\nBenzo-g, h, i-perylen (0,0005 – 0,32)μg/l\nBenzo-a-piren (0,002 – 0,20) μg/l\nChryzen (0,005 – 0,20) μg/l\nDibenzo(a,h)antracen (0,002 – 0,80) μg/l\nFenantren (0,002 – 0,16) μg/l\nFluoranten (0,004 – 0,20) μg/l\nFluoren (0,0006 – 0,40) μg/l\nIndeno(1,2,3-c,d)piren (0,0005 – 0,20) μg/l\nNaftalen (0,004 – 2,0) μg/l\nPiren (0,009 – 0,40) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-08/PO wyd. 01 z 16.06.2020 r.","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"Acenaphthene","range":"(0,0003 – 4,0) μg/l"},{"name":"Anthracene","range":"(0,001 – 0,08) μg/l"},{"name":"Benzo-a-anthracene","range":"(0,003 – 0,20) μg/l"},{"name":"Benzo-b-fluoranthene","range":"(0,004 – 0,08) μg/l"},{"name":"Benzo-k-fluoranthene","range":"(0,002 – 0,08) μg/l"},{"name":"Benzo-g, h, i-perylene","range":"(0,0005 – 0,32)μg/l"},{"name":"Benzo-a-pyrene","range":"(0,002 – 0,20) μg/l"},{"name":"Chrysene","range":"(0,005 – 0,20) μg/l"},{"name":"Dibenzo(a,h)anthracene","range":"(0,002 – 0,80) μg/l"},{"name":"Phenanthrene","range":"(0,002 – 0,16) μg/l"},{"name":"Fluoranthene","range":"(0,004 – 0,20) μg/l"},{"name":"Fluorene","range":"(0,0006 – 0,40) μg/l"},{"name":"Indeno(1,2,3-c,d)piren","range":"(0,0005 – 0,20) μg/l"},{"name":"Naphthalene","range":"(0,004 – 2,0) μg/l"},{"name":"Pyrene","range":"(0,009 – 0,40) μg/l"}],"search_en":"Water, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Acenaphthene Anthracene Benzo-a-anthracene Benzo-b-fluoranthene Benzo-k-fluoranthene Benzo-g, h, i-perylene Benzo-a-pyrene Chrysene Dibenzo(a,h)anthracene Phenanthrene Fluoranthene Fluorene Naphthalene Pyrene PB-08/PO wyd. 01 z 16.06.2020 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, wastewater","search_zh":"水、废水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苊 蒽 苯并-a-蒽 苯并-b-荧蒽 苯并-k-荧蒽 苯并-a-芘 䓛 二苯并(a,h)蒽 菲 荧蒽 芴 萘 芘 PB-08/PO wyd. 01 z 16.06.2020 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、废水","methodology_zh":"多环芳烃（PAHs）浓度","parameters_zh":[{"name":"苊","range":"(0,0003 – 4,0) μg/l"},{"name":"蒽","range":"(0,001 – 0,08) μg/l"},{"name":"苯并-a-蒽","range":"(0,003 – 0,20) μg/l"},{"name":"苯并-b-荧蒽","range":"(0,004 – 0,08) μg/l"},{"name":"苯并-k-荧蒽","range":"(0,002 – 0,08) μg/l"},{"name":"Benzo-g, h, i-perylen","range":"(0,0005 – 0,32)μg/l"},{"name":"苯并-a-芘","range":"(0,002 – 0,20) μg/l"},{"name":"䓛","range":"(0,005 – 0,20) μg/l"},{"name":"二苯并(a,h)蒽","range":"(0,002 – 0,80) μg/l"},{"name":"菲","range":"(0,002 – 0,16) μg/l"},{"name":"荧蒽","range":"(0,004 – 0,20) μg/l"},{"name":"芴","range":"(0,0006 – 0,40) μg/l"},{"name":"Indeno(1,2,3-c,d)piren","range":"(0,0005 – 0,20) μg/l"},{"name":"萘","range":"(0,004 – 2,0) μg/l"},{"name":"芘","range":"(0,009 – 0,40) μg/l"}]},{"_id":"6a832aeb884ede9a1b2c5354","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma wybranych WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wybranych WWA (z obliczeń)","reference":"PB-08/PO wyd. 01 z 16.06.2020 r.","norm_bases":["PB-08/PO wyd. 01 z 16.06.2020 r."],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma wybranych WWA (z obliczeń) PB-08/PO wyd. 01 z 16.06.2020 r. Woda, scieki Suma wybranych WWA (z obliczen) PB-08/PO wyd. 01 z 16.06.2020 r.","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of selected PAH (calculated)","search_en":"Water, wastewater Sum of selected PAH (calculated) PB-08/PO wyd. 01 z 16.06.2020 r.","test_object_en":"Water, wastewater","search_zh":"水、废水 选定多环芳烃总量（由计算得出） PB-08/PO wyd. 01 z 16.06.2020 r.","test_object_zh":"水、废水","methodology_zh":"选定多环芳烃总量（由计算得出）"},{"_id":"6a832aeb884ede9a1b2c5355","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego (OWO) Stezenie rozpuszczonego wegla organicznego (RWO)\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Infrared spectrometry method (IR) Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法（IR）"},{"_id":"6a832aeb884ede9a1b2c5356","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,010 – 30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,010 – 30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 30) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 30) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5357","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,01 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 100) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 100) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5358","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0017 – 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0017 – 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0017 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0017 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0017 – 0,25) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0017 – 0,25) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5359","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,00 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,00 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,00 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,00 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(7,00 – 1000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(7,00 – 1000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c535a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 65,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010 – 65,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,010 – 65,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,010 – 65,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,010 – 65,0) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 65,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 7 i 8 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c535b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,010 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,010 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,010 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,010 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,010 – 25,0) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 25,0) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a832aeb884ede9a1b2c535c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy (fenole lotne)","parameters":[{"name":"Zakres","range":"(0,003 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy (fenole lotne)\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy (fenole lotne)\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Woda, scieki Indeks fenolowy (fenole lotne)\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index (volatile phenols)","parameters_en":[{"name":"Range","range":"(0,003 – 0,10) mg/l"}],"search_en":"Water, wastewater Phenol index (volatile phenols) Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,003 – 0,10) mg/l"}],"search_zh":"水、废水 酚指数（挥发酚） 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数（挥发酚）"},{"_id":"6a832aeb884ede9a1b2c535d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie surfaktantów anionowych (substancji powierzchniowo-czynnych anionowych)","parameters":[{"name":"Zakres","range":"(0,050 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów anionowych (substancji powierzchniowo-czynnych anionowych)\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych (substancji powierzchniowo-czynnych anionowych)\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, scieki Stezenie surfaktantow anionowych (substancji powierzchniowo-czynnych anionowych)\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic surfactant concentration (anionic surface-active agents)","parameters_en":[{"name":"Range","range":"(0,050 – 5,0) mg/l"}],"search_en":"Water, wastewater Anionic surfactant concentration (anionic surface-active agents) Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 5,0) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c535e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(4 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (4 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (4 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (4 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(4 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(4 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c535f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03","norm_bases":["PN-EN 15216: 2022-03"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 5000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216: 2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 5000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216: 2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c5360","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(1,4 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (1,4 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (1,4 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (1,4 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(1,4 – 5000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(1,4 – 5000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5361","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5362","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,25 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,25 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,25 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,25 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,25 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5363","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 – 10 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 – 10 000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 – 10 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 – 10 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(30 – 10 000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(30 – 10 000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c5364","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (2 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (2 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (2 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2 – 5000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2 – 5000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5365","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks nadmanganianowy\nZakres (1,0 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki Indeks nadmanganianowy\nZakres (1,0 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/l O2"}],"search_en":"Water, wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/l O2"}],"search_zh":"水、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5366","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5367","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,60 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,60 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,60 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,60 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,60 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,60 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5368","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wyd.1 z 16.01.2026 r.","norm_bases":["PB-26/CLB wyd.1 z 16.01.2026 r."],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wyd.1 z 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wyd.1 z 16.01.2026 r.","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5369","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(2,5 – 25) g/kg"},{"name":"Zakres","range":"(0,25 – 2,5) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (2,5 – 25) g/kg\nZakres (0,25 – 2,5) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (2,5 – 25) g/kg\nZakres (0,25 – 2,5) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (2,5 – 25) g/kg\nZakres (0,25 – 2,5) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(2,5 – 25) g/kg"},{"name":"Range","range":"(0,25 – 2,5) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(2,5 – 25) g/kg"},{"name":"范围","range":"(0,25 – 2,5) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 范围 PN-EN 14672:2006","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a832aeb884ede9a1b2c536a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(2,5 – 97,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (2,5 – 97,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (2,5 – 97,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (2,5 – 97,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(2,5 – 97,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(2,5 – 97,0) %"}],"search_zh":"污泥 干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a832aeb884ede9a1b2c536b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(4,0 – 98,0) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(2,0 – 96,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (4,0 – 98,0) %\nZawartość wody\nZakres (2,0 – 96,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres:\nZakres (4,0 – 98,0) %\nZawartość wody\nZakres (2,0 – 96,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Osady sciekowe Sucha pozostalosc\nZakres:\nZakres (4,0 – 98,0) %\nZawartosc wody\nZakres (2,0 – 96,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(4,0 – 98,0) %"},{"name":"Water content"},{"name":"Range","range":"(2,0 – 96,0) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(4,0 – 98,0) %"},{"name":"水分含量"},{"name":"范围","range":"(2,0 – 96,0) %"}],"search_zh":"污泥 干残渣 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣"},{"_id":"6a832aeb884ede9a1b2c536c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 50) g/kg"},{"name":"Zakres","range":"(0,10 – 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres:\nZakres (1,0 – 50) g/kg\nZakres (0,10 – 5,0) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres:\nZakres (1,0 – 50) g/kg\nZakres (0,10 – 5,0) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres:\nZakres (1,0 – 50) g/kg\nZakres (0,10 – 5,0) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(1,0 – 50) g/kg"},{"name":"Range","range":"(0,10 – 5,0) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 50) g/kg"},{"name":"范围","range":"(0,10 – 5,0) %"}],"search_zh":"污泥 氨氮含量 滴定法 范围 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a832aeb884ede9a1b2c536d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5,0 – 80) g/kg"},{"name":"Zakres","range":"(0,5 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (5,0 – 80) g/kg\nZakres (0,5 – 8,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres:\nZakres (5,0 – 80) g/kg\nZakres (0,5 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres:\nZakres (5,0 – 80) g/kg\nZakres (0,5 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(5,0 – 80) g/kg"},{"name":"Range","range":"(0,5 – 8,0) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 80) g/kg"},{"name":"范围","range":"(0,5 – 8,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a832aeb884ede9a1b2c536e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH - w H20","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH - w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H20","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge pH - in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a832aeb884ede9a1b2c536f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 190805","methodology":"Zawartość całkowitego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(1,0 – 400) g/kg"},{"name":"Zakres","range":"(0,10 – 40) %"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Zawartość całkowitego węgla organicznego (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nZakres (0,10 – 40) %\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)","norm_bases":["PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 190805 Zawartość całkowitego węgla organicznego (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nZakres (0,10 – 40) %\nMetoda spektrometrii w podczerwieni (IR) PN-EN ISO 15936:2022-07 metoda B (bezpośrednia) Osady sciekowe, Odpady O) kod: 190805 Zawartosc calkowitego wegla organicznego (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nZakres (0,10 – 40) %\nMetoda spektrometrii w podczerwieni (IR) PN-EN ISO 15936:2022-07 metoda B (bezposrednia)","categories":["water","environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(1,0 – 400) g/kg"},{"name":"Range","range":"(0,10 – 40) %"}],"search_en":"Total organic carbon (TOC) content Infrared spectrometry method (IR) Range Range PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"范围","range":"(1,0 – 400) g/kg"},{"name":"范围","range":"(0,10 – 40) %"}],"search_zh":"总有机碳（TOC）含量 红外光谱法（IR） 范围 范围 PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a832aeb884ede9a1b2c5370","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w H20","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H20","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Soil pH - in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5371","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 10 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 10 000) μS/cm\nMetoda konduktometryczna","reference":"PN-ISO 11265+AC1:1997","norm_bases":["PN-ISO 11265+AC1:1997"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Przewodność elektryczna właściwa\nZakres (10 – 10 000) μS/cm\nMetoda konduktometryczna PN-ISO 11265+AC1:1997 Gleba Przewodnosc elektryczna wlasciwa\nZakres (10 – 10 000) μS/cm\nMetoda konduktometryczna PN-ISO 11265+AC1:1997","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 10 000) μS/cm"}],"search_en":"Soil Electrical conductivity Conductometric method Range PN-ISO 11265+AC1:1997","technique_en":"Conductometric method","test_object_en":"Soil","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 10 000) μS/cm"}],"search_zh":"土壤 电导率 电导法 范围 PN-ISO 11265+AC1:1997","technique_zh":"电导法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5372","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Acenaften","range":"(0,007 – 10) mg/kg"},{"name":"Antracen","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-a-antracen","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-b-fluoranten","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-k-fluoranten","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-g,h,i-perylen","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-a-piren","range":"(0,001 – 10) mg/kg"},{"name":"Chryzen","range":"(0,001 – 10) mg/kg"},{"name":"Fenantren","range":"(0,001 – 10) mg/kg"},{"name":"Fluoranten","range":"(0,001 – 10) mg/kg"},{"name":"Fluoren","range":"(0,001 – 10) mg/kg"},{"name":"Dibenzo(a,h)antracen","range":"(0,002 – 10) mg/kg"},{"name":"Indeno-1,2,3-c,d-piren","range":"(0,001 – 10) mg/kg"},{"name":"Naftalen","range":"(0,003 – 10) mg/kg"},{"name":"Piren","range":"(0,001 – 10) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAcenaften (0,007 – 10) mg/kg\nAntracen (0,001 – 10) mg/kg\nBenzo-a-antracen (0,001 – 10) mg/kg\nBenzo-b-fluoranten (0,001 – 10) mg/kg\nBenzo-k-fluoranten (0,001 – 10) mg/kg\nBenzo-g,h,i-perylen (0,001 – 10) mg/kg\nBenzo-a-piren (0,001 – 10) mg/kg\nChryzen (0,001 – 10) mg/kg\nFenantren (0,001 – 10) mg/kg\nFluoranten (0,001 – 10) mg/kg\nFluoren (0,001 – 10) mg/kg\nDibenzo(a,h)antracen (0,002 – 10) mg/kg\nIndeno-1,2,3-c,d-piren (0,001 – 10) mg/kg\nNaftalen (0,003 – 10) mg/kg\nPiren (0,001 – 10) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN 17503:2022-07","norm_bases":["PN-EN 17503:2022-07"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAcenaften (0,007 – 10) mg/kg\nAntracen (0,001 – 10) mg/kg\nBenzo-a-antracen (0,001 – 10) mg/kg\nBenzo-b-fluoranten (0,001 – 10) mg/kg\nBenzo-k-fluoranten (0,001 – 10) mg/kg\nBenzo-g,h,i-perylen (0,001 – 10) mg/kg\nBenzo-a-piren (0,001 – 10) mg/kg\nChryzen (0,001 – 10) mg/kg\nFenantren (0,001 – 10) mg/kg\nFluoranten (0,001 – 10) mg/kg\nFluoren (0,001 – 10) mg/kg\nDibenzo(a,h)antracen (0,002 – 10) mg/kg\nIndeno-1,2,3-c,d-piren (0,001 – 10) mg/kg\nNaftalen (0,003 – 10) mg/kg\nPiren (0,001 – 10) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN 17503:2022-07 Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nAcenaften (0,007 – 10) mg/kg\nAntracen (0,001 – 10) mg/kg\nBenzo-a-antracen (0,001 – 10) mg/kg\nBenzo-b-fluoranten (0,001 – 10) mg/kg\nBenzo-k-fluoranten (0,001 – 10) mg/kg\nBenzo-g,h,i-perylen (0,001 – 10) mg/kg\nBenzo-a-piren (0,001 – 10) mg/kg\nChryzen (0,001 – 10) mg/kg\nFenantren (0,001 – 10) mg/kg\nFluoranten (0,001 – 10) mg/kg\nFluoren (0,001 – 10) mg/kg\nDibenzo(a,h)antracen (0,002 – 10) mg/kg\nIndeno-1,2,3-c,d-piren (0,001 – 10) mg/kg\nNaftalen (0,003 – 10) mg/kg\nPiren (0,001 – 10) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN 17503:2022-07","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"Acenaphthene","range":"(0,007 – 10) mg/kg"},{"name":"Anthracene","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-a-anthracene","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-b-fluoranthene","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-k-fluoranthene","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-g,h,i-perylene","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-a-pyrene","range":"(0,001 – 10) mg/kg"},{"name":"Chrysene","range":"(0,001 – 10) mg/kg"},{"name":"Phenanthrene","range":"(0,001 – 10) mg/kg"},{"name":"Fluoranthene","range":"(0,001 – 10) mg/kg"},{"name":"Fluorene","range":"(0,001 – 10) mg/kg"},{"name":"Dibenzo(a,h)anthracene","range":"(0,002 – 10) mg/kg"},{"name":"Indeno-1,2,3-c,d-pyrene","range":"(0,001 – 10) mg/kg"},{"name":"Naphthalene","range":"(0,003 – 10) mg/kg"},{"name":"Pyrene","range":"(0,001 – 10) mg/kg"}],"search_en":"Soil Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Acenaphthene Anthracene Benzo-a-anthracene Benzo-b-fluoranthene Benzo-k-fluoranthene Benzo-g,h,i-perylene Benzo-a-pyrene Chrysene Phenanthrene Fluoranthene Fluorene Dibenzo(a,h)anthracene Indeno-1,2,3-c,d-pyrene Naphthalene Pyrene PN-EN 17503:2022-07","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Soil","search_zh":"土壤 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 苊 蒽 苯并-a-蒽 苯并-b-荧蒽 苯并-k-荧蒽 苯并-a-芘 䓛 菲 荧蒽 芴 二苯并(a,h)蒽 萘 芘 PN-EN 17503:2022-07","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"土壤","methodology_zh":"多环芳烃（PAHs）含量","parameters_zh":[{"name":"苊","range":"(0,007 – 10) mg/kg"},{"name":"蒽","range":"(0,001 – 10) mg/kg"},{"name":"苯并-a-蒽","range":"(0,001 – 10) mg/kg"},{"name":"苯并-b-荧蒽","range":"(0,001 – 10) mg/kg"},{"name":"苯并-k-荧蒽","range":"(0,001 – 10) mg/kg"},{"name":"Benzo-g,h,i-perylen","range":"(0,001 – 10) mg/kg"},{"name":"苯并-a-芘","range":"(0,001 – 10) mg/kg"},{"name":"䓛","range":"(0,001 – 10) mg/kg"},{"name":"菲","range":"(0,001 – 10) mg/kg"},{"name":"荧蒽","range":"(0,001 – 10) mg/kg"},{"name":"芴","range":"(0,001 – 10) mg/kg"},{"name":"二苯并(a,h)蒽","range":"(0,002 – 10) mg/kg"},{"name":"Indeno-1,2,3-c,d-piren","range":"(0,001 – 10) mg/kg"},{"name":"萘","range":"(0,003 – 10) mg/kg"},{"name":"芘","range":"(0,001 – 10) mg/kg"}]},{"_id":"6a832aeb884ede9a1b2c5373","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Suma wybranych WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wybranych WWA (z obliczeń)","reference":"PN-EN 17503:2022-07","norm_bases":["PN-EN 17503:2022-07"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma wybranych WWA (z obliczeń) PN-EN 17503:2022-07 Gleba Suma wybranych WWA (z obliczen) PN-EN 17503:2022-07","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of selected PAH (calculated)","search_en":"Soil Sum of selected PAH (calculated) PN-EN 17503:2022-07","test_object_en":"Soil","search_zh":"土壤 选定多环芳烃总量（由计算得出） PN-EN 17503:2022-07","test_object_zh":"土壤","methodology_zh":"选定多环芳烃总量（由计算得出）"},{"_id":"6a832aeb884ede9a1b2c5374","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość całkowitego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(1,0 – 400) g/kg"},{"name":"Zakres","range":"(0,10 – 40) %"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Zawartość całkowitego węgla organicznego (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nZakres (0,10 – 40) %\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)","norm_bases":["PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość całkowitego węgla organicznego (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nZakres (0,10 – 40) %\nMetoda spektrometrii w podczerwieni (IR) PN-EN ISO 15936:2022-07 metoda B (bezpośrednia) Gleba Zawartosc calkowitego wegla organicznego (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nZakres (0,10 – 40) %\nMetoda spektrometrii w podczerwieni (IR) PN-EN ISO 15936:2022-07 metoda B (bezposrednia)","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(1,0 – 400) g/kg"},{"name":"Range","range":"(0,10 – 40) %"}],"search_en":"Soil Total organic carbon (TOC) content Infrared spectrometry method (IR) Range Range PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 400) g/kg"},{"name":"范围","range":"(0,10 – 40) %"}],"search_zh":"土壤 总有机碳（TOC）含量 红外光谱法（IR） 范围 范围 PN-EN ISO 15936:2022-07 metoda B (bezpośrednia)","test_object_zh":"土壤","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a832aeb884ede9a1b2c5375","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(30,0 - 99,7) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(0,3 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (30,0 - 99,7) %\nZawartość wody\nZakres (0,3 – 70,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (30,0 - 99,7) %\nZawartość wody\nZakres (0,3 – 70,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Gleba Sucha masa\nZakres:\nZakres (30,0 - 99,7) %\nZawartosc wody\nZakres (0,3 – 70,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(30,0 - 99,7) %"},{"name":"Water content"},{"name":"Range","range":"(0,3 – 70,0) %"}],"search_en":"Soil Dry matter Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(30,0 - 99,7) %"},{"name":"水分含量"},{"name":"范围","range":"(0,3 – 70,0) %"}],"search_zh":"土壤 干物质 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5376","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 190805","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(1,0 – 1000) mg/kg (0,10 – 100) mg/l"},{"name":"Chlorki","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"},{"name":"Siarczany","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (1,0 – 1000) mg/kg (0,10 – 100) mg/l\nChlorki (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nSiarczany (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457- 2:2006","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012","PN-EN 12457- 2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 190805 Stężenie anionów\nZakres:\nAzotany (1,0 – 1000) mg/kg (0,10 – 100) mg/l\nChlorki (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nSiarczany (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457- 2:2006 Odpady O) kod: 190805 Stezenie anionow\nZakres:\nAzotany (1,0 – 1000) mg/kg (0,10 – 100) mg/l\nChlorki (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nSiarczany (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457- 2:2006","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(1,0 – 1000) mg/kg (0,10 – 100) mg/l"},{"name":"Chlorides","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"},{"name":"Sulfates","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"}],"search_en":"Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates Chlorides Sulfates PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457- 2:2006","technique_en":"Ion chromatography with conductometric detection (IC-CD)","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(1,0 – 1000) mg/kg (0,10 – 100) mg/l"},{"name":"氯化物","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"},{"name":"硫酸盐","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"}],"search_zh":"阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氯化物 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457- 2:2006","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a832aeb884ede9a1b2c5377","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 190805","methodology":"Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(20 – 10 000) mg/kg"},{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres:\nZakres (20 – 10 000) mg/kg\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999 | PN-EN 12457- 2:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457- 2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 190805 Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres:\nZakres (20 – 10 000) mg/kg\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457- 2:2006 Odpady O) kod: 190805 Stezenie ogolnego wegla organicznego (OWO) Stezenie rozpuszczonego wegla organicznego (RWO)\nZakres:\nZakres (20 – 10 000) mg/kg\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457- 2:2006","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(20 – 10 000) mg/kg"},{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Infrared spectrometry method (IR) Range Range PN-EN 1484:1999 | PN-EN 12457- 2:2006","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"范围","range":"(20 – 10 000) mg/kg"},{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"红外光谱法（IR） 范围 范围 PN-EN 1484:1999 | PN-EN 12457- 2:2006","technique_zh":"红外光谱法（IR）"},{"_id":"6a832aeb884ede9a1b2c5378","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 190805","methodology":"Indeks fenolowy (fenole lotne)","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/kg"},{"name":"Zakres","range":"(0,003 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy (fenole lotne)\nZakres:\nZakres (0,03 – 1,0) mg/kg\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 | PN-EN 12457- 2:2006","norm_bases":["PN-ISO 6439:1994","PN-EN 12457- 2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 190805 Indeks fenolowy (fenole lotne)\nZakres:\nZakres (0,03 – 1,0) mg/kg\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 | PN-EN 12457- 2:2006 Odpady O) kod: 190805 Indeks fenolowy (fenole lotne)\nZakres:\nZakres (0,03 – 1,0) mg/kg\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 | PN-EN 12457- 2:2006","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index (volatile phenols)","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/kg"},{"name":"Range","range":"(0,003 – 0,10) mg/l"}],"search_en":"Phenol index (volatile phenols) Spectrophotometric method Range Range PN-ISO 6439:1994 | PN-EN 12457- 2:2006","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/kg"},{"name":"范围","range":"(0,003 – 0,10) mg/l"}],"search_zh":"酚指数（挥发酚） 分光光度法 范围 范围 PN-ISO 6439:1994 | PN-EN 12457- 2:2006","technique_zh":"分光光度法","methodology_zh":"酚指数（挥发酚）"},{"_id":"6a832aeb884ede9a1b2c5379","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 190805","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(40 – 50 000) mg/kg"},{"name":"Zakres","range":"(4 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres:\nZakres (40 – 50 000) mg/kg\nZakres (4 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002 | PN-EN 12457- 2:2006","norm_bases":["PN-ISO 9280:2002","PN-EN 12457- 2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 190805 Stężenie siarczanów\nZakres:\nZakres (40 – 50 000) mg/kg\nZakres (4 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457- 2:2006 Odpady O) kod: 190805 Stezenie siarczanow\nZakres:\nZakres (40 – 50 000) mg/kg\nZakres (4 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457- 2:2006","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(40 – 50 000) mg/kg"},{"name":"Range","range":"(4 – 5000) mg/l"}],"search_en":"Sulfate concentration Gravimetric method Range Range PN-ISO 9280:2002 | PN-EN 12457- 2:2006","technique_en":"Gravimetric method","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40 – 50 000) mg/kg"},{"name":"范围","range":"(4 – 5000) mg/l"}],"search_zh":"硫酸盐浓度 重量法 范围 范围 PN-ISO 9280:2002 | PN-EN 12457- 2:2006","technique_zh":"重量法"},{"_id":"6a832aeb884ede9a1b2c537a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 190805","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(500 – 50 0000) mg/kg"},{"name":"Zakres","range":"(50 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 50 0000) mg/kg\nZakres (50 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03 | PN-EN 12457- 2:2006","norm_bases":["PN-EN 15216: 2022-03","PN-EN 12457- 2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 190805 Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 50 0000) mg/kg\nZakres (50 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 | PN-EN 12457- 2:2006 Odpady O) kod: 190805 Calkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 50 0000) mg/kg\nZakres (50 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 | PN-EN 12457- 2:2006","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(500 – 50 0000) mg/kg"},{"name":"Range","range":"(50 – 5000) mg/l"}],"search_en":"Total dissolved solids (TDS) Gravimetric method Range Range PN-EN 15216: 2022-03 | PN-EN 12457- 2:2006","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(500 – 50 0000) mg/kg"},{"name":"范围","range":"(50 – 5000) mg/l"}],"search_zh":"溶解性总固体（TDS） 重量法 范围 范围 PN-EN 15216: 2022-03 | PN-EN 12457- 2:2006","technique_zh":"重量法","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c537b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 190805","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(20 – 50 000) mg/kg"},{"name":"Zakres","range":"(2 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres:\nZakres (20 – 50 000) mg/kg\nZakres (2 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 | PN-EN 12457- 2:2006","norm_bases":["PN-ISO 9297:1994","PN-EN 12457- 2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 190805 Stężenie chlorków\nZakres:\nZakres (20 – 50 000) mg/kg\nZakres (2 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457- 2:2006 Odpady O) kod: 190805 Stezenie chlorkow\nZakres:\nZakres (20 – 50 000) mg/kg\nZakres (2 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457- 2:2006","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(20 – 50 000) mg/kg"},{"name":"Range","range":"(2 – 5000) mg/l"}],"search_en":"Chloride concentration Titrimetric method Range Range PN-ISO 9297:1994 | PN-EN 12457- 2:2006","technique_en":"Titrimetric method","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(20 – 50 000) mg/kg"},{"name":"范围","range":"(2 – 5000) mg/l"}],"search_zh":"氯化物浓度 滴定法 范围 范围 PN-ISO 9297:1994 | PN-EN 12457- 2:2006","technique_zh":"滴定法"},{"_id":"6a832aeb884ede9a1b2c537c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 170503* 170504","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(1,0 – 1000) mg/kg (0,10 – 100) mg/l"},{"name":"Chlorki","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"},{"name":"Siarczany","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (1,0 – 1000) mg/kg (0,10 – 100) mg/l\nChlorki (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nSiarczany (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012","PN-EN 12457-2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 170503* 170504 Stężenie anionów\nZakres:\nAzotany (1,0 – 1000) mg/kg (0,10 – 100) mg/l\nChlorki (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nSiarczany (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457-2:2006 Odpady O) kod: 170503* 170504 Stezenie anionow\nZakres:\nAzotany (1,0 – 1000) mg/kg (0,10 – 100) mg/l\nChlorki (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nSiarczany (10 – 10 000) mg/kg (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457-2:2006","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(1,0 – 1000) mg/kg (0,10 – 100) mg/l"},{"name":"Chlorides","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"},{"name":"Sulfates","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"}],"search_en":"Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates Chlorides Sulfates PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457-2:2006","technique_en":"Ion chromatography with conductometric detection (IC-CD)","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(1,0 – 1000) mg/kg (0,10 – 100) mg/l"},{"name":"氯化物","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"},{"name":"硫酸盐","range":"(10 – 10 000) mg/kg (1,0 – 1000) mg/l"}],"search_zh":"阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氯化物 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012 | PN-EN 12457-2:2006","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a832aeb884ede9a1b2c537d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 170503* 170504","methodology":"Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(20 – 10 000) mg/kg"},{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres:\nZakres (20 – 10 000) mg/kg\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 170503* 170504 Stężenie ogólnego węgla organicznego (OWO) Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres:\nZakres (20 – 10 000) mg/kg\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006 Odpady O) kod: 170503* 170504 Stezenie ogolnego wegla organicznego (OWO) Stezenie rozpuszczonego wegla organicznego (RWO)\nZakres:\nZakres (20 – 10 000) mg/kg\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(20 – 10 000) mg/kg"},{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Infrared spectrometry method (IR) Range Range PN-EN 1484:1999 | PN-EN 12457-2:2006","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"范围","range":"(20 – 10 000) mg/kg"},{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"红外光谱法（IR） 范围 范围 PN-EN 1484:1999 | PN-EN 12457-2:2006","technique_zh":"红外光谱法（IR）"},{"_id":"6a832aeb884ede9a1b2c537e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 170503* 170504","methodology":"Indeks fenolowy (fenole lotne)","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/kg"},{"name":"Zakres","range":"(0,003 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy (fenole lotne)\nZakres:\nZakres (0,03 – 1,0) mg/kg\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 6439:1994","PN-EN 12457-2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 170503* 170504 Indeks fenolowy (fenole lotne)\nZakres:\nZakres (0,03 – 1,0) mg/kg\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 | PN-EN 12457-2:2006 Odpady O) kod: 170503* 170504 Indeks fenolowy (fenole lotne)\nZakres:\nZakres (0,03 – 1,0) mg/kg\nZakres (0,003 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 | PN-EN 12457-2:2006","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index (volatile phenols)","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/kg"},{"name":"Range","range":"(0,003 – 0,10) mg/l"}],"search_en":"Phenol index (volatile phenols) Spectrophotometric method Range Range PN-ISO 6439:1994 | PN-EN 12457-2:2006","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/kg"},{"name":"范围","range":"(0,003 – 0,10) mg/l"}],"search_zh":"酚指数（挥发酚） 分光光度法 范围 范围 PN-ISO 6439:1994 | PN-EN 12457-2:2006","technique_zh":"分光光度法","methodology_zh":"酚指数（挥发酚）"},{"_id":"6a832aeb884ede9a1b2c537f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 170503* 170504","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(40 – 50 000) mg/kg"},{"name":"Zakres","range":"(4 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres:\nZakres (40 – 50 000) mg/kg\nZakres (4 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9280:2002","PN-EN 12457-2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 170503* 170504 Stężenie siarczanów\nZakres:\nZakres (40 – 50 000) mg/kg\nZakres (4 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-2:2006 Odpady O) kod: 170503* 170504 Stezenie siarczanow\nZakres:\nZakres (40 – 50 000) mg/kg\nZakres (4 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-2:2006","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(40 – 50 000) mg/kg"},{"name":"Range","range":"(4 – 5000) mg/l"}],"search_en":"Sulfate concentration Gravimetric method Range Range PN-ISO 9280:2002 | PN-EN 12457-2:2006","technique_en":"Gravimetric method","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40 – 50 000) mg/kg"},{"name":"范围","range":"(4 – 5000) mg/l"}],"search_zh":"硫酸盐浓度 重量法 范围 范围 PN-ISO 9280:2002 | PN-EN 12457-2:2006","technique_zh":"重量法"},{"_id":"6a832aeb884ede9a1b2c5380","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 170503* 170504","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(500 – 50 0000) mg/kg"},{"name":"Zakres","range":"(50 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 50 0000) mg/kg\nZakres (50 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03 | PN-EN 12457-2:2006","norm_bases":["PN-EN 15216: 2022-03","PN-EN 12457-2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 170503* 170504 Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 50 0000) mg/kg\nZakres (50 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 | PN-EN 12457-2:2006 Odpady O) kod: 170503* 170504 Calkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 50 0000) mg/kg\nZakres (50 – 5000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 | PN-EN 12457-2:2006","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(500 – 50 0000) mg/kg"},{"name":"Range","range":"(50 – 5000) mg/l"}],"search_en":"Total dissolved solids (TDS) Gravimetric method Range Range PN-EN 15216: 2022-03 | PN-EN 12457-2:2006","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(500 – 50 0000) mg/kg"},{"name":"范围","range":"(50 – 5000) mg/l"}],"search_zh":"溶解性总固体（TDS） 重量法 范围 范围 PN-EN 15216: 2022-03 | PN-EN 12457-2:2006","technique_zh":"重量法","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c5381","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Odpady O) kod: 170503* 170504","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(20 – 50 000) mg/kg"},{"name":"Zakres","range":"(2 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres:\nZakres (20 – 50 000) mg/kg\nZakres (2 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9297:1994","PN-EN 12457-2:2006"],"lab_section":"Pracownia w Koninie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 170503* 170504 Stężenie chlorków\nZakres:\nZakres (20 – 50 000) mg/kg\nZakres (2 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-2:2006 Odpady O) kod: 170503* 170504 Stezenie chlorkow\nZakres:\nZakres (20 – 50 000) mg/kg\nZakres (2 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-2:2006","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(20 – 50 000) mg/kg"},{"name":"Range","range":"(2 – 5000) mg/l"}],"search_en":"Chloride concentration Titrimetric method Range Range PN-ISO 9297:1994 | PN-EN 12457-2:2006","technique_en":"Titrimetric method","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(20 – 50 000) mg/kg"},{"name":"范围","range":"(2 – 5000) mg/l"}],"search_zh":"氯化物浓度 滴定法 范围 范围 PN-ISO 9297:1994 | PN-EN 12457-2:2006","technique_zh":"滴定法"},{"_id":"6a832aeb884ede9a1b2c5382","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5383","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 100) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/l O2"}],"search_en":"Water, wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/l O2"}],"search_zh":"水、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5384","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5385","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5386","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c5387","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,010 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,010 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 50) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 50) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5388","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,001 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,001 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 2,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 2,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5389","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,10 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,10 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 200) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 200) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c538a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,018 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,018 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,018 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,018 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,018 – 200) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,018 – 200) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 8 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c538b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,005 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,005 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,005 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,005 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,005 – 100) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,005 – 100) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a832aeb884ede9a1b2c538c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c538d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03","norm_bases":["PN-EN 15216: 2022-03"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 1000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 1000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03","categories":["water"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216: 2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 1000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216: 2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c538e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,30 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,30 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,30 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,30 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,30 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c538f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 400) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 400) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5390","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wapnia\nZakres (2 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, scieki Stezenie wapnia\nZakres (2 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2 – 200) mg/l"}],"search_en":"Water, wastewater Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2 – 200) mg/l"}],"search_zh":"水、废水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"钙浓度"},{"_id":"6a832aeb884ede9a1b2c5391","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wyd.1 z 16.01.2026 r.","norm_bases":["PB-26/CLB wyd.1 z 16.01.2026 r."],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wyd.1 z 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wyd.1 z 16.01.2026 r.","categories":["water"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wyd.1 z 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c5392","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 100) g/kg"},{"name":"Zakres","range":"(0,10 - 10) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres:\nZakres (1,0 – 100) g/kg\nZakres (0,10 - 10) %\nMetoda spektrofotometryczna","reference":"PN-EN 14671:2007","norm_bases":["PN-EN 14671:2007"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres:\nZakres (1,0 – 100) g/kg\nZakres (0,10 - 10) %\nMetoda spektrofotometryczna PN-EN 14671:2007 Osady sciekowe Zawartosc azotu amonowego\nZakres:\nZakres (1,0 – 100) g/kg\nZakres (0,10 - 10) %\nMetoda spektrofotometryczna PN-EN 14671:2007","categories":["water"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(1,0 – 100) g/kg"},{"name":"Range","range":"(0,10 - 10) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Spectrophotometric method Range Range PN-EN 14671:2007","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 100) g/kg"},{"name":"范围","range":"(0,10 - 10) %"}],"search_zh":"污泥 氨氮含量 分光光度法 范围 范围 PN-EN 14671:2007","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a832aeb884ede9a1b2c5393","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,0045 – 50) g/kg"},{"name":"Zakres","range":"(0,00045 – 5) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,0045 – 50) g/kg\nZakres (0,00045 – 5) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (0,0045 – 50) g/kg\nZakres (0,00045 – 5) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (0,0045 – 50) g/kg\nZakres (0,00045 – 5) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,0045 – 50) g/kg"},{"name":"Range","range":"(0,00045 – 5) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,0045 – 50) g/kg"},{"name":"范围","range":"(0,00045 – 5) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 范围 PN-EN 14672:2006","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a832aeb884ede9a1b2c5394","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (0,1 – 99,9) %\nZawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres:\nZakres (0,1 – 99,9) %\nZawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Osady sciekowe Sucha pozostalosc\nZakres:\nZakres (0,1 – 99,9) %\nZawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"},{"name":"Water content"},{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"},{"name":"水分含量"},{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"污泥 干残渣 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣"},{"_id":"6a832aeb884ede9a1b2c5395","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"污泥 干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a832aeb884ede9a1b2c5396","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,350 – 100) g/kg"},{"name":"Zakres","range":"(0,035 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (0,350 – 100) g/kg\nZakres (0,035 – 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres:\nZakres (0,350 – 100) g/kg\nZakres (0,035 – 10) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres:\nZakres (0,350 – 100) g/kg\nZakres (0,035 – 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,350 – 100) g/kg"},{"name":"Range","range":"(0,035 – 10) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,350 – 100) g/kg"},{"name":"范围","range":"(0,035 – 10) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a832aeb884ede9a1b2c5397","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H20","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in H20","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge pH – in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a832aeb884ede9a1b2c5398","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (0,1 – 99,9) %\nZawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (0,1 – 99,9) %\nZawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Gleba Sucha masa\nZakres:\nZakres (0,1 – 99,9) %\nZawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"},{"name":"Water content"},{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Soil Dry matter Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"},{"name":"水分含量"},{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"土壤 干物质 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c5399","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"pH – w H20","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Lesznie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH – w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH – w H20\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in H20","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Soil pH – in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c539a","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali","parameters":[{"name":"Antymon","range":"(0,0003 – 10) mg/l"},{"name":"Arsen","range":"(0,001 – 10) mg/l"},{"name":"Bar","range":"(0,001 – 10) mg/l"},{"name":"Beryl","range":"(0,0002 – 10) mg/l"},{"name":"Bor","range":"(0,010 – 10) mg/l"},{"name":"Chrom","range":"(0,0005 – 10) mg/l"},{"name":"Cyna","range":"(0,001 – 10) mg/l"},{"name":"Glin","range":"(0,005 – 10) mg/l"},{"name":"Kadm","range":"(0,00002 – 10) mg/l"},{"name":"Kobalt","range":"(0,001 – 10) mg/l"},{"name":"Miedż","range":"(0,001 – 10) mg/l"},{"name":"Molibden","range":"(0,001 – 10) mg/l"},{"name":"Nikiel","range":"(0,001 – 10) mg/l"},{"name":"Ołów","range":"(0,0003 – 10) mg/l"},{"name":"Selen","range":"(0,002 – 10) mg/l"},{"name":"Srebro","range":"(0,001 – 10) mg/l"},{"name":"Tal","range":"(0,0005 – 10) mg/l"},{"name":"Tytan","range":"(0,001 – 10) mg/l"},{"name":"Wanad","range":"(0,001 – 10) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nAntymon (0,0003 – 10) mg/l\nArsen (0,001 – 10) mg/l\nBar (0,001 – 10) mg/l\nBeryl (0,0002 – 10) mg/l\nBor (0,010 – 10) mg/l\nChrom (0,0005 – 10) mg/l\nCyna (0,001 – 10) mg/l\nGlin (0,005 – 10) mg/l\nKadm (0,00002 – 10) mg/l\nKobalt (0,001 – 10) mg/l\nMiedż (0,001 – 10) mg/l\nMolibden (0,001 – 10) mg/l\nNikiel (0,001 – 10) mg/l\nOłów (0,0003 – 10) mg/l\nSelen (0,002 – 10) mg/l\nSrebro (0,001 – 10) mg/l\nTal (0,0005 – 10) mg/l\nTytan (0,001 – 10) mg/l\nWanad (0,001 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS)","reference":"PN-EN ISO 17294-2: 2024-04","norm_bases":["PN-EN ISO 17294-2: 2024-04"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali\nZakres:\nAntymon (0,0003 – 10) mg/l\nArsen (0,001 – 10) mg/l\nBar (0,001 – 10) mg/l\nBeryl (0,0002 – 10) mg/l\nBor (0,010 – 10) mg/l\nChrom (0,0005 – 10) mg/l\nCyna (0,001 – 10) mg/l\nGlin (0,005 – 10) mg/l\nKadm (0,00002 – 10) mg/l\nKobalt (0,001 – 10) mg/l\nMiedż (0,001 – 10) mg/l\nMolibden (0,001 – 10) mg/l\nNikiel (0,001 – 10) mg/l\nOłów (0,0003 – 10) mg/l\nSelen (0,002 – 10) mg/l\nSrebro (0,001 – 10) mg/l\nTal (0,0005 – 10) mg/l\nTytan (0,001 – 10) mg/l\nWanad (0,001 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS) PN-EN ISO 17294-2: 2024-04 Woda Stezenie metali\nZakres:\nAntymon (0,0003 – 10) mg/l\nArsen (0,001 – 10) mg/l\nBar (0,001 – 10) mg/l\nBeryl (0,0002 – 10) mg/l\nBor (0,010 – 10) mg/l\nChrom (0,0005 – 10) mg/l\nCyna (0,001 – 10) mg/l\nGlin (0,005 – 10) mg/l\nKadm (0,00002 – 10) mg/l\nKobalt (0,001 – 10) mg/l\nMiedz (0,001 – 10) mg/l\nMolibden (0,001 – 10) mg/l\nNikiel (0,001 – 10) mg/l\nOlow (0,0003 – 10) mg/l\nSelen (0,002 – 10) mg/l\nSrebro (0,001 – 10) mg/l\nTal (0,0005 – 10) mg/l\nTytan (0,001 – 10) mg/l\nWanad (0,001 – 10) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP- MS) PN-EN ISO 17294-2: 2024-04","categories":["materials","water"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Antimony","range":"(0,0003 – 10) mg/l"},{"name":"Arsenic","range":"(0,001 – 10) mg/l"},{"name":"Barium","range":"(0,001 – 10) mg/l"},{"name":"Beryllium","range":"(0,0002 – 10) mg/l"},{"name":"Boron","range":"(0,010 – 10) mg/l"},{"name":"Chromium","range":"(0,0005 – 10) mg/l"},{"name":"Tin","range":"(0,001 – 10) mg/l"},{"name":"Aluminium","range":"(0,005 – 10) mg/l"},{"name":"Cadmium","range":"(0,00002 – 10) mg/l"},{"name":"Cobalt","range":"(0,001 – 10) mg/l"},{"name":"Copper","range":"(0,001 – 10) mg/l"},{"name":"Molybdenum","range":"(0,001 – 10) mg/l"},{"name":"Nickel","range":"(0,001 – 10) mg/l"},{"name":"Lead","range":"(0,0003 – 10) mg/l"},{"name":"Selenium","range":"(0,002 – 10) mg/l"},{"name":"Silver","range":"(0,001 – 10) mg/l"},{"name":"Thallium","range":"(0,0005 – 10) mg/l"},{"name":"Titanium","range":"(0,001 – 10) mg/l"},{"name":"Vanadium","range":"(0,001 – 10) mg/l"}],"search_en":"Water Metal concentrations Inductively coupled plasma mass spectrometry method (ICP- MS) Antimony Arsenic Barium Beryllium Boron Chromium Tin Aluminium Cadmium Cobalt Copper Molybdenum Nickel Lead Selenium Silver Thallium Titanium Vanadium PN-EN ISO 17294-2: 2024-04","technique_en":"Inductively coupled plasma mass spectrometry method (ICP- MS)","test_object_en":"Water","methodology_zh":"金属浓度","parameters_zh":[{"name":"锑","range":"(0,0003 – 10) mg/l"},{"name":"砷","range":"(0,001 – 10) mg/l"},{"name":"钡","range":"(0,001 – 10) mg/l"},{"name":"铍","range":"(0,0002 – 10) mg/l"},{"name":"硼","range":"(0,010 – 10) mg/l"},{"name":"铬","range":"(0,0005 – 10) mg/l"},{"name":"锡","range":"(0,001 – 10) mg/l"},{"name":"铝","range":"(0,005 – 10) mg/l"},{"name":"镉","range":"(0,00002 – 10) mg/l"},{"name":"钴","range":"(0,001 – 10) mg/l"},{"name":"Miedż","range":"(0,001 – 10) mg/l"},{"name":"钼","range":"(0,001 – 10) mg/l"},{"name":"镍","range":"(0,001 – 10) mg/l"},{"name":"铅","range":"(0,0003 – 10) mg/l"},{"name":"硒","range":"(0,002 – 10) mg/l"},{"name":"银","range":"(0,001 – 10) mg/l"},{"name":"铊","range":"(0,0005 – 10) mg/l"},{"name":"钛","range":"(0,001 – 10) mg/l"},{"name":"钒","range":"(0,001 – 10) mg/l"}],"search_zh":"水 金属浓度 锑 砷 钡 铍 硼 铬 锡 铝 镉 钴 钼 镍 铅 硒 银 铊 钛 钒 PN-EN ISO 17294-2: 2024-04","test_object_zh":"水"},{"_id":"6a832aeb884ede9a1b2c539b","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0080 – 1,0) μg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej (AFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej (AFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0080 – 1,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rtęci\nZakres (0,0080 – 1,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej (AFS) PN-EN ISO 17852:2009 Woda Stezenie rteci\nZakres (0,0080 – 1,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0080 – 1,0) μg/l"}],"search_en":"Water Mercury concentration Atomic fluorescence spectrometry method (AFS) Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry method (AFS)","test_object_en":"Water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0080 – 1,0) μg/l"}],"search_zh":"水 汞浓度 范围 PN-EN ISO 17852:2009","test_object_zh":"水"},{"_id":"6a832aeb884ede9a1b2c539c","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Węglowodory ropopochodne - Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,010 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Węglowodory ropopochodne - Indeks oleju mineralnego\nZakres (0,010 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Węglowodory ropopochodne - Indeks oleju mineralnego\nZakres (0,010 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Weglowodory ropopochodne - Indeks oleju mineralnego\nZakres (0,010 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petroleum hydrocarbons - Mineral oil index","parameters_en":[{"name":"Range","range":"(0,010 – 50) mg/l"}],"search_en":"Water, wastewater Petroleum hydrocarbons - Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 50) mg/l"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c539d","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie aldehydu mrówkowego (formaldehydu)","parameters":[{"name":"Zakres","range":"(0,015 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie aldehydu mrówkowego (formaldehydu)\nZakres (0,015 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-71/C-04593","norm_bases":["PN-71/C-04593"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie aldehydu mrówkowego (formaldehydu)\nZakres (0,015 – 2,0) mg/l\nMetoda spektrofotometryczna PN-71/C-04593 Woda, scieki Stezenie aldehydu mrowkowego (formaldehydu)\nZakres (0,015 – 2,0) mg/l\nMetoda spektrofotometryczna PN-71/C-04593","categories":["water"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formic aldehyde (formaldehyde) concentration","parameters_en":[{"name":"Range","range":"(0,015 – 2,0) mg/l"}],"search_en":"Water, wastewater Formic aldehyde (formaldehyde) concentration Spectrophotometric method Range PN-71/C-04593","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,015 – 2,0) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-71/C-04593","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c539e","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,002 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,002 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,002 – 30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,002 – 30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 30) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 30) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c539f","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,01 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 100) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 100) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53a0","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,001 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,001 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 20) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 20) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53a1","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres stężeń","range":"(0,005 – 1,4) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres stężeń (0,005 – 1,4) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604.02 | PN-77/C-04604.08","norm_bases":["PN-77/C-04604.02","PN-77/C-04604.08"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres stężeń (0,005 – 1,4) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.02 | PN-77/C-04604.08 Woda, scieki Stezenie chromu (VI)\nZakres stezen (0,005 – 1,4) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.02 | PN-77/C-04604.08","categories":["water"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Concentration range","range":"(0,005 – 1,4) mg/l"}],"search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Concentration range PN-77/C-04604.02 | PN-77/C-04604.08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","search_zh":"水、废水 六价铬浓度 分光光度法 PN-77/C-04604.02 | PN-77/C-04604.08","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"六价铬浓度"},{"_id":"6a832aeb884ede9a1b2c53a2","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres stężeń","range":"(5,0 – 50) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres stężeń (5,0 – 50) μg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres stężeń (5,0 – 50) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda, scieki Stezenie chromu (VI)\nZakres stezen (5,0 – 50) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Concentration range","range":"(5,0 – 50) μg/l"}],"search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Concentration range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","search_zh":"水、废水 六价铬浓度 分光光度法 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"六价铬浓度"},{"_id":"6a832aeb884ede9a1b2c53a3","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,009 – 160) mg/l P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,009 – 160) mg/l P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,009 – 160) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,009 – 160) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,009 – 160) mg/l P"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,009 – 160) mg/l P"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkty 7 i 8 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53a4","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,003 – 160) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,003 – 160) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,003 – 160) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,003 – 160) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,003 – 160) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,003 – 160) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a832aeb884ede9a1b2c53a5","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy (fenole lotne)","parameters":[{"name":"Zakres","range":"(0,003 – 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy (fenole lotne)\nZakres (0,003 – 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy (fenole lotne)\nZakres (0,003 – 0,50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Woda, scieki Indeks fenolowy (fenole lotne)\nZakres (0,003 – 0,50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index (volatile phenols)","parameters_en":[{"name":"Range","range":"(0,003 – 0,50) mg/l"}],"search_en":"Water, wastewater Phenol index (volatile phenols) Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,003 – 0,50) mg/l"}],"search_zh":"水、废水 酚指数（挥发酚） 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数（挥发酚）"},{"_id":"6a832aeb884ede9a1b2c53a6","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53a7","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (1,0 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573/01","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a832aeb884ede9a1b2c53a8","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 15216: 2022-03","norm_bases":["PN-EN 15216: 2022-03"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 10000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 10000) mg/l\nMetoda wagowa PN-EN 15216: 2022-03","categories":["water"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 10000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216: 2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 10000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216: 2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a832aeb884ede9a1b2c53a9","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(1,4 – 20000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (1,4 – 20000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (1,4 – 20000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (1,4 – 20000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(1,4 – 20000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(1,4 – 20000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53aa","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,40 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,40 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,40 – 5000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,40 – 5000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,40 – 5000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,40 – 5000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53ab","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,30 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,30 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,30 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,30 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,30 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53ac","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 –10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 –10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 –10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (30 –10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(30 –10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(30 –10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c53ad","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2 – 10000) mg/l"}],"technique":"Metoda miareczkowania","techniques":["Metoda miareczkowania"],"computed":[],"activity":"Stężenie chlorków\nZakres (2 – 10000) mg/l\nMetoda miareczkowania","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (2 – 10000) mg/l\nMetoda miareczkowania PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (2 – 10000) mg/l\nMetoda miareczkowania PN-ISO 9297:1994","categories":["water"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2 – 10000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titration method Range PN-ISO 9297:1994","technique_en":"Titration method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2 – 10000) mg/l"}],"search_zh":"水、废水 氯化物浓度 范围 PN-ISO 9297:1994","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53ae","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,40 – 500) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,40 – 500) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks nadmanganianowy\nZakres (0,40 – 500) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki Indeks nadmanganianowy\nZakres (0,40 – 500) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,40 – 500) mg/l O2"}],"search_en":"Water, wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,40 – 500) mg/l O2"}],"search_zh":"水、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53af","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a832aeb884ede9a1b2c53b0","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,00 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (7,00 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (7,00 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (7,00 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(7,00 – 150) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(7,00 – 150) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832aeb884ede9a1b2c53b1","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a832aeb884ede9a1b2c53b2","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wyd.1 z dnia 16.01.2026 r.","norm_bases":["PB-26/CLB wyd.1 z dnia 16.01.2026 r."],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wyd.1 z dnia 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wyd.1 z dnia 16.01.2026 r.","categories":["water"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wyd.1 z dnia 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wyd.1 z dnia 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832aeb884ede9a1b2c53b3","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,011 – 15) %"},{"name":"Zakres","range":"(0,11 – 150) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres:\nZakres (0,011 – 15) %\nZakres (0,11 – 150) g/kg\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres:\nZakres (0,011 – 15) %\nZakres (0,11 – 150) g/kg\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres:\nZakres (0,011 – 15) %\nZakres (0,11 – 150) g/kg\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,011 – 15) %"},{"name":"Range","range":"(0,11 – 150) g/kg"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,011 – 15) %"},{"name":"范围","range":"(0,11 – 150) g/kg"}],"search_zh":"污泥 氨氮含量 滴定法 范围 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a832aeb884ede9a1b2c53b4","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,24 – 15) %"},{"name":"Zakres","range":"(2,4 – 150) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (0,24 – 15) %\nZakres (2,4 – 150) g/kg\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres:\nZakres (0,24 – 15) %\nZakres (2,4 – 150) g/kg\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres:\nZakres (0,24 – 15) %\nZakres (2,4 – 150) g/kg\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,24 – 15) %"},{"name":"Range","range":"(2,4 – 150) g/kg"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,24 – 15) %"},{"name":"范围","range":"(2,4 – 150) g/kg"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a832aeb884ede9a1b2c53b5","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH - w H20","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH - w H20\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w H20\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H20","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Sewage sludge pH - in H20 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污泥 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a832aeb884ede9a1b2c53b6","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 190805","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,01 – 5,0) %"},{"name":"Zakres","range":"(0,10 – 50) g/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,01 – 5,0) %\nZakres (0,10 – 50) g/kg\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 190805 Zawartość fosforu ogólnego\nZakres:\nZakres (0,01 – 5,0) %\nZakres (0,10 – 50) g/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady sciekowe, Odpady O) kod: 190805 Zawartosc fosforu ogolnego\nZakres:\nZakres (0,01 – 5,0) %\nZakres (0,10 – 50) g/kg\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water","environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,01 – 5,0) %"},{"name":"Range","range":"(0,10 – 50) g/kg"}],"search_en":"Total phosphorus content Spectrophotometric method Range Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,01 – 5,0) %"},{"name":"范围","range":"(0,10 – 50) g/kg"}],"search_zh":"总磷含量 分光光度法 范围 范围 PN-EN 14672:2006","technique_zh":"分光光度法","methodology_zh":"总磷含量"},{"_id":"6a832aeb884ede9a1b2c53b7","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 190805","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (0,1 – 99,9) %\nZawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 190805 Sucha pozostałość\nZakres:\nZakres (0,1 – 99,9) %\nZawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Osady sciekowe, Odpady O) kod: 190805 Sucha pozostalosc\nZakres:\nZakres (0,1 – 99,9) %\nZawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"},{"name":"Water content"},{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Dry residue Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"},{"name":"水分含量"},{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"干残渣 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","methodology_zh":"干残渣"},{"_id":"6a832aeb884ede9a1b2c53b8","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 190805","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(1,2 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (1,2 – 85,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 190805 Straty przy prażeniu suchej masy (LOI)\nZakres (1,2 – 85,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, Odpady O) kod: 190805 Straty przy prazeniu suchej masy (LOI)\nZakres (1,2 – 85,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(1,2 – 85,0) %"}],"search_en":"Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,2 – 85,0) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a832aeb884ede9a1b2c53b9","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 190805","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,24 – 15) %"},{"name":"Zakres","range":"(2,4 – 150) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (0,24 – 15) %\nZakres (2,4 – 150) g/kg\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 190805 Zawartość azotu Kjeldahla\nZakres:\nZakres (0,24 – 15) %\nZakres (2,4 – 150) g/kg\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe, Odpady O) kod: 190805 Zawartosc azotu Kjeldahla\nZakres:\nZakres (0,24 – 15) %\nZakres (2,4 – 150) g/kg\nMetoda miareczkowa PN-EN 13342:2002","categories":["water","environment"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,24 – 15) %"},{"name":"Range","range":"(2,4 – 150) g/kg"}],"search_en":"Kjeldahl nitrogen content Titrimetric method Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,24 – 15) %"},{"name":"范围","range":"(2,4 – 150) g/kg"}],"search_zh":"凯氏氮含量 滴定法 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a832aeb884ede9a1b2c53ba","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość węglowodorów C10 - C40","parameters":[{"name":"Zakres","range":"(30 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów C10 - C40\nZakres (30 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość węglowodorów C10 - C40\nZakres (30 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Zawartosc weglowodorow C10 - C40\nZakres (30 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons C10 - C40","parameters_en":[{"name":"Range","range":"(30 – 10000) mg/kg"}],"search_en":"Soil Content of hydrocarbons C10 - C40 Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(30 – 10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c53bb","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Benzyna suma (węglowodory C6 – C12)","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Benzyna suma (węglowodory C6 – C12)\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-06/PO wyd. 01 z 16.06.2020 r.","norm_bases":["PB-06/PO wyd. 01 z 16.06.2020 r."],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Benzyna suma (węglowodory C6 – C12)\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-06/PO wyd. 01 z 16.06.2020 r. Gleba Benzyna suma (weglowodory C6 – C12)\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-06/PO wyd. 01 z 16.06.2020 r.","categories":["environment","petro"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gasoline total (C6 – C12 hydrocarbons)","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/kg"}],"search_en":"Soil Gasoline total (C6 – C12 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PB-06/PO wyd. 01 z 16.06.2020 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-06/PO wyd. 01 z 16.06.2020 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c53bc","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość oleju mineralnego (węglowodory C12 – C35)","parameters":[{"name":"Zakres","range":"(20 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego (węglowodory C12 – C35)\nZakres (20 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość oleju mineralnego (węglowodory C12 – C35)\nZakres (20 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Zawartosc oleju mineralnego (weglowodory C12 – C35)\nZakres (20 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment","petro"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C12 – C35 hydrocarbons)","parameters_en":[{"name":"Range","range":"(20 – 10000) mg/kg"}],"search_en":"Soil Mineral oil content (C12 – C35 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(20 – 10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a832aeb884ede9a1b2c53bd","lab_id":"69ad52a3de79e566650fb169","country":"PL","accr_number":"AB 199","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(35,0 – 99,9) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(0,1 – 65,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (35,0 – 99,9) %\nZawartość wody\nZakres (0,1 – 65,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Pile","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (35,0 – 99,9) %\nZawartość wody\nZakres (0,1 – 65,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Gleba Sucha masa\nZakres:\nZakres (35,0 – 99,9) %\nZawartosc wody\nZakres (0,1 – 65,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(35,0 – 99,9) %"},{"name":"Water content"},{"name":"Range","range":"(0,1 – 65,0) %"}],"search_en":"Soil Dry matter Gravimetric method Range Water content Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(35,0 – 99,9) %"},{"name":"水分含量"},{"name":"范围","range":"(0,1 – 65,0) %"}],"search_zh":"土壤 干物质 重量法 范围 水分含量 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"土壤"}],"has_pdf":true}