🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1946 (Jelenia Góra, Poland). Its accreditation scope covers 20 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, water, Water intended for human consumption, water, Wastewater. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, MPN method.
At a glance
- Accreditation number: PCA AB 1946
- Methods in scope: 20
- Types of test objects: 4
- Techniques used: 10
- City: Jelenia Góra, Poland
- Valid until: 25.08.2029
- Accreditation number
- AB 1946
- Accreditation body
- PCA
- Address
- "WODNIK" Sp. z o.o., Pl. Piastowski 21, 58-560 Jelenia Góra, Dział Laboratorium
- City
- Jelenia Góra, Poland
- Valid until
- 25.08.2029
What this laboratory tests (4)
- Water intended for human consumption — 12 methods
- Wastewater, water — 3 methods
- Water intended for human consumption, water — 3 methods
- Wastewater — 2 methods
Analytical techniques used (10)
- Membrane filtration method — 4 methods
- Spectrophotometric method — 3 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Conductometric method — 1 method
- Gravimetric method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Optical method — 1 method
Laboratory locations
- Dział Laboratorium — ul. Wróblewskiego 101
- Laboratorium Wody — ul. Wróblewskiego 101, 58-560 Jelenia Góra
- Laboratorium Ścieków — ul. Lwówecka, 58-506 Jelenia Góra
Accreditation scope — test methods (20)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption, water | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 2 | Water intended for human consumption, water | Colour Range (2 − 250) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | |
| 3 | Water intended for human consumption, water | Electrical conductivity Range (50 − 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 4 | Water intended for human consumption | Water sampling for chemical and physical testing Temperature Range (0,0 – 80,0) °C |
PN-ISO 5667-5:2017-10 | PN-77/C-04584 | ||
| 5 | Water intended for human consumption | Free chlorine concentration Range (0,03 – 4,00) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 6 | Water intended for human consumption | Turbidity Range (0,30 – 2,0) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 pkt 5.3 | |
| 7 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | |
| 8 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | |
| 9 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 10 | Water intended for human consumption | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 11 | Water intended for human consumption | Total microorganism count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 12 | Water intended for human consumption | Clostridium perfringens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 13 | Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 14 | Water intended for human consumption | Most probable Number, Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 15 | Water intended for human consumption | Water sampling for microbiological testing | PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6 | ||
| 16 | Wastewater, water | Biochemical oxygen demand - BOD5 Range (2,0 – 2000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 17 | Wastewater, water | Chemical oxygen demand - COD-SP Range (9,00 – 10 000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705: 2005 | |
| 18 | Wastewater, water | Total suspended solids (TSS) Range (2,0 – 3000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 19 | Wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 20 | Wastewater | Sampling for chemical and physical testing Temperature Range (0,0 – 50,0) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
Reference standards (17)
PN-77/C-04584
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 pkt 5.3
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705: 2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10