{"lab":{"_id":"69ad52a3de79e566650fbaab","accr_number":"AB 1946","country":"PL","accr_body":"PCA","address":"\"WODNIK\" Sp. z o.o., Pl. Piastowski 21, 58-560 Jelenia Góra, Dział Laboratorium","categories":["water","microbiology"],"city":"Jelenia Góra","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1946.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji \"wodnik\" sp. z o.o., pl. piastowski 21, 58-560 jelenia góra, dział laboratorium water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:04.449Z","valid_from":"","valid_until":"25.08.2029","website":"","parsed_at":"2026-08-13T08:04:50.297Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201946,podmiot.html","fields_of_testing":[{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"}],"issue":{"no":"2","date":"05.08.2026"},"parse_date":"2026-08-13T08:04:50.297Z","parse_source":"agent-claude-code","map_coord":[50.903103,15.734431],"map_geo":"nominatim-city","lab_locations":[{"name":"Dział Laboratorium","address":"ul. Wróblewskiego 101","city":null,"postal":null},{"name":"Laboratorium Wody","address":"ul. Wróblewskiego 101, 58-560 Jelenia Góra","city":"Jelenia Góra","postal":"58-560"},{"name":"Laboratorium Ścieków","address":"ul. Lwówecka, 58-506 Jelenia Góra","city":"Jelenia Góra","postal":"58-506"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/f49d9b8290fdc6b56168852fd6c09dde/AB%201946.pdf","has_en":true,"category_counts":{"water":20,"microbiology":5},"category_scores":{"water":16,"microbiology":1},"has_zh":true},"methods":[{"_id":"6a7d7aa20636ba417e41b781","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption, water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、水"},{"_id":"6a7d7aa20636ba417e41b782","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 − 250) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 − 250) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Barwa\nZakres (2 − 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda do spozycia przez ludzi, woda Barwa\nZakres (2 − 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 − 250) mg/l Pt"}],"search_en":"Water intended for human consumption, water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 − 250) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a7d7aa20636ba417e41b783","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50 − 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 − 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Przewodność elektryczna właściwa\nZakres (50 − 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, woda Przewodnosc elektryczna wlasciwa\nZakres (50 − 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50 − 2500) μS/cm"}],"search_en":"Water intended for human consumption, water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 − 2500) μS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、水"},{"_id":"6a7d7aa20636ba417e41b784","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 80,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 80,0) °C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań chemicznych i fizycznych Temperatura\nZakres (0,0 – 80,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek wody do badan chemicznych i fizycznych Temperatura\nZakres (0,0 – 80,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 80,0) °C"}],"search_en":"Water intended for human consumption Water sampling for chemical and physical testing Temperature Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 – 80,0) °C"}],"search_zh":"生活饮用水 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b785","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,03 – 4,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,03 – 4,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,03 – 4,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,03 – 4,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 4,00) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 4,00) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b786","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,30 – 2,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,30 – 2,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 pkt 5.3","norm_bases":["PN-EN ISO 7027-1:2016-09 pkt 5.3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,30 – 2,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 pkt 5.3 Woda do spozycia przez ludzi Metnosc\nZakres (0,30 – 2,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 pkt 5.3","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,30 – 2,0) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 pkt 5.3","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 – 2,0) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 pkt 5.3","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b787","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b788","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b789","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 肠道肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"肠道肠球菌数"},{"_id":"6a7d7aa20636ba417e41b78a","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a7d7aa20636ba417e41b78b","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 36 °C","search_en":"Water intended for human consumption Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a7d7aa20636ba417e41b78c","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a7d7aa20636ba417e41b78d","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b78e","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna Liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna Liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna Liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna Liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable Number, Escherichia coli","search_en":"Water intended for human consumption Most probable Number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7d7aa20636ba417e41b78f","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek wody do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wody do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6 Woda do spozycia przez ludzi Pobieranie probek wody do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water sampling for microbiological testing","search_en":"Water intended for human consumption Water sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 用于微生物检验的水样采集 PN-EN ISO 19458:2007 z wył. pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5 i 4.4.6","test_object_zh":"生活饮用水","methodology_zh":"用于微生物检验的水样采集"},{"_id":"6a7d7aa20636ba417e41b790","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 2000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d7aa20636ba417e41b791","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-SP","parameters":[{"name":"Zakres","range":"(9,00 – 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-SP\nZakres (9,00 – 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705: 2005","norm_bases":["PN-ISO 15705: 2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu - ChZT-SP\nZakres (9,00 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705: 2005 Scieki, woda Chemiczne zapotrzebowanie tlenu - ChZT-SP\nZakres (9,00 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705: 2005","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-SP","parameters_en":[{"name":"Range","range":"(9,00 – 10 000) mg/l O2"}],"search_en":"Wastewater, water Chemical oxygen demand - COD-SP Spectrophotometric method Range PN-ISO 15705: 2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(9,00 – 10 000) mg/l O2"}],"search_zh":"废水、水 分光光度法 范围 PN-ISO 15705: 2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a7d7aa20636ba417e41b792","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a7d7aa20636ba417e41b793","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a7d7aa20636ba417e41b794","lab_id":"69ad52a3de79e566650fbaab","country":"PL","accr_number":"AB 1946","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"}],"has_pdf":true}