🇵🇱 JR SPACE Sp. z o.o. PL
Environment
JR SPACE Sp. z o.o. is a laboratory accredited by PCA under number AB 1880 (Zabrze, Poland). Its accreditation scope covers 41 test methods in the following areas: Environment. Test objects include: Waste gases, General environment − noise from installations, equipment and indus…, Machinery and equipment – noise, Workplace environment – noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Method using flat filters and absorbing solutions.
At a glance
- Accreditation number: PCA AB 1880
- Methods in scope: 41
- Types of test objects: 4
- Techniques used: 14
- City: Zabrze, Poland
- Accreditation number
- AB 1880
- Accreditation body
- PCA
- Address
- Laboratorium Ochrony Środowiska LABOTECH, ul. Srebrna 4, 41-800 Zabrze
- City
- Zabrze, Poland
What this laboratory tests (4)
- Waste gases — 35 methods
- General environment − noise from installations, equipment and industrial plants — 2 methods
- Machinery and equipment – noise — 2 methods
- Workplace environment – noise — 2 methods
Analytical techniques used (14)
- Direct measurement method — 3 methods
- Gravimetric method — 2 methods
- Method using flat filters and absorbing solutions — 2 methods
- Non-dispersive infrared spectrometry (NDIR) — 2 methods
- Chemiluminescence method (CLD) — 1 method
- Condensation-adsorption method — 1 method
- Differential pressure measurement method — 1 method
- Electrochemical method — 1 method
- Method using absorbing solutions — 1 method
- Method using activated carbon — 1 method
- Non-dispersive infrared spectrometry NDIR — 1 method
- Paramagnetic method (PMD) — 1 method
- Stagnation pressure method — 1 method
- Thoron method — 1 method
Laboratory locations
- Laboratorium Ochrony Środowiska LABOTECH — Aleja Walentego Roździeńskiego 188E, 40-203 Katowice
Accreditation scope — test methods (41)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice | |||||
| 1 | Waste gases | Gas velocity and volume flow for differential pressures > 20 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Differential pressure measurement method | PN-EN ISO 16911-1:2013-07 | |
| 2 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 3 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 4 | Waste gases | Dust concentration: Range (1,0 − 100000) mg/m³ Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 5 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 6 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 7 | Waste gases | Dust concentration Range (0,5– 50) mg/m³ Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 8 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 9 | Waste gases | Oxygen concentration O2 (1,0 – 21) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method (PMD) | PN-EN 14789:2017-04 | |
| 10 | Waste gases | Oxygen concentration Range (1,0 – 21) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Electrochemical method | PN-ISO 10396:2001 | |
| 11 | Waste gases | Stężenie dwutlenku siarki, dwutlenek węgla SO2 (6,0 – 2290) mg/m³ CO2 (1,5 – 20) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry NDIR | PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r. | |
| 12 | Waste gases | Emission of sulphur dioxide, carbon dioxide (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r. | ||
| 13 | Waste gases | Carbon monoxide concentration Range (5,0 – 1500) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | |
| 14 | Waste gases | Carbon monoxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 15058:2017-04 | ||
| 15 | Waste gases | Concentration of nitrogen monoxide, nitrogen oxides NO (4,0 – 1100) mg/m3 NOx (5,0 – 1680) mg/m³ Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 16 | Waste gases | Emission of nitrogen oxides (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14792:2017-04 | ||
| 17 | Waste gases | Water vapour concentration (H2O) Range (4,0 – 40) % Water vapour content (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-04 | |
| 18 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Method using flat filters and absorbing solutions | PN-EN 14385:2025-05 | |
| 19 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 20 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Method using flat filters and absorbing solutions | PN-EN 13211+AC:2006 | |
| 21 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 22 | Waste gases | Sampling for determination of HF concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | CEN/TS 17340:2020 | ||
| 23 | Waste gases | HF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | CEN/TS 17340:2020 | ||
| 24 | Waste gases | Sulphur dioxide concentration Range (2,78 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791:2017-04 | |
| 25 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 26 | Waste gases | CO2 concentration Range (1,5 – 20) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 27 | Waste gases | CO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 12039:2019 | ||
| 28 | Waste gases | Sampling for the determination of hydrogen chloride Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Method using absorbing solutions | PN-EN-1911:2011 | |
| 29 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN-1911:2011 | ||
| 30 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Method using activated carbon | PN-EN 13649:2005 | |
| 31 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13649:2005 | ||
| 32 | Waste gases | Sampling for the determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 33 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 34 | Waste gases | Sampling for determination of PM 2,5 and PM 10 dust concentration | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 35 | Waste gases | PM 2,5 and PM 10 dust emission (calculated) | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 36 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (35 – 135) dB C-weighted peak sound pressure level (50 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11 | |
| 37 | Workplace environment – noise | Noise exposure level normalised to: (calculated) an 8-hour daily working time tygodnia pracy |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11 | ||
| 38 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound level, LAeq Range (20 – 135) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F | |
| 39 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F | ||
| 40 | Machinery and equipment – noise | A-weighted equivalent sound pressure level Range (20 – 134) dB |
Direct measurement method | PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4 | |
| 41 | Machinery and equipment – noise | Sound power level (calculated) | PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4 | ||
Reference standards (22)
CEN/TS 17340:2020
ISO 12039:2019
ISO 15713:2006
PB-4/2023 wyd. 1 z dn. 12.01.2023 r.
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN ISO 16911-1:2013-07
PN-EN ISO 21877:2020-03
PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11
PN-EN-1911:2011
PN-ISO 10396:2001
PN-N-01307:1994
PN-Z-04030-7:1994
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F