{"lab":{"_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","address":"Laboratorium Ochrony Środowiska LABOTECH, ul. Srebrna 4, 41-800 Zabrze","categories":["environment"],"city":"Zabrze","imported_at":"2026-03-08T10:42:43.265Z","methods_count":41,"name":"JR SPACE Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1880.pdf"],"scope_summary":"","search_text":"jr space sp. z o.o. laboratorium ochrony środowiska labotech, ul. srebrna 4, 41-800 zabrze other environment materials metrology","status":"active","updated_at":"2026-03-08T14:51:00.669Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:21:19.738Z","location":{"type":"Point","coordinates":[18.7857,50.3249]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201880,podmiot.html","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) – gases (waste gases)"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"5","date":"07.08.2026"},"parse_date":"2026-08-17T15:21:19.738Z","parse_source":"agent-claude-code","map_coord":[50.314379,18.745153],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Ochrony Środowiska LABOTECH","address":"Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","city":"Katowice","postal":"40-203"}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8d7fa05cd857e552e80a18af994eb799/AB%201880.pdf","has_en":true,"category_counts":{"other":20,"environment":20,"materials":2},"category_scores":{"other":9.52,"environment":9.52,"materials":0.1},"has_zh":true},"methods":[{"_id":"6a8326ef884ede9a1b2c5100","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 20 Pa","parameters":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"computed":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 20 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07","norm_bases":["PN-EN ISO 16911-1:2013-07"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych > 20 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych > 20 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas velocity and volume flow for differential pressures > 20 Pa","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas velocity and volume flow for differential pressures > 20 Pa Differential pressure measurement method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN ISO 16911-1:2013-07","technique_en":"Differential pressure measurement method","test_object_en":"Waste gases","search_zh":"废气 差压测量法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN ISO 16911-1:2013-07","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"差压测量法"},{"_id":"6a8326ef884ede9a1b2c5101","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a8326ef884ede9a1b2c5102","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5103","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu:","parameters":[{"name":"Zakres","range":"(1,0 − 100000) mg/m³"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu:\nZakres (1,0 − 100000) mg/m³\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu:\nZakres (1,0 − 100000) mg/m³\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu:\nZakres (1,0 − 100000) mg/m³\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration:","parameters_en":[{"name":"Range","range":"(1,0 − 100000) mg/m³"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration: Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 − 100000) mg/m³"}],"search_zh":"废气 重量法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5104","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5105","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5106","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,5– 50) mg/m³"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,5– 50) mg/m³\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,5– 50) mg/m³\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,5– 50) mg/m³\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,5– 50) mg/m³"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,5– 50) mg/m³"}],"search_zh":"废气 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5107","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5108","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"O2","range":"(1,0 – 21) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"computed":[],"activity":"Stężenie tlenu\nO2 (1,0 – 21) %\nMetoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nO2 (1,0 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nO2 (1,0 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"O2","range":"(1,0 – 21) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Oxygen concentration Paramagnetic method (PMD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law O2 PN-EN 14789:2017-04","technique_en":"Paramagnetic method (PMD)","test_object_en":"Waste gases","search_zh":"废气 氧浓度 顺磁法（PMD） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 O2 PN-EN 14789:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"O2","range":"(1,0 – 21) %"}],"methodology_zh":"氧浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"顺磁法（PMD）"},{"_id":"6a8326ef884ede9a1b2c5109","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(1,0 – 21) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu\nZakres (1,0 – 21) %\nMetoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (1,0 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu\nZakres (1,0 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 21) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Oxygen concentration Electrochemical method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-ISO 10396:2001","technique_en":"Electrochemical method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 – 21) %"}],"search_zh":"废气 氧浓度 电化学法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-ISO 10396:2001","technique_zh":"电化学法","test_object_zh":"废气","methodology_zh":"氧浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c510a","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki, dwutlenek węgla","parameters":[{"name":"SO2","range":"(6,0 – 2290) mg/m³"},{"name":"CO2","range":"(1,5 – 20) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni NDIR","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni NDIR"],"computed":[],"activity":"Stężenie dwutlenku siarki, dwutlenek węgla\nZakres:\nSO2 (6,0 – 2290) mg/m³\nCO2 (1,5 – 20) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni NDIR","reference":"PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","norm_bases":["PN-ISO 10396:2001","PB-4/2023 wyd. 1 z dn. 12.01.2023 r."],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, dwutlenek węgla\nZakres:\nSO2 (6,0 – 2290) mg/m³\nCO2 (1,5 – 20) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni NDIR PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r. Gazy odlotowe Stezenie dwutlenku siarki, dwutlenek wegla\nZakres:\nSO2 (6,0 – 2290) mg/m³\nCO2 (1,5 – 20) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni NDIR PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"SO2","range":"(6,0 – 2290) mg/m³"},{"name":"CO2","range":"(1,5 – 20) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Non-dispersive infrared spectrometry NDIR Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law SO2 CO2 PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","technique_en":"Non-dispersive infrared spectrometry NDIR","test_object_en":"Waste gases","search_zh":"废气 非分散红外光谱法 NDIR 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 SO2 CO2 PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(6,0 – 2290) mg/m³"},{"name":"CO2","range":"(1,5 – 20) %"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"非分散红外光谱法 NDIR"},{"_id":"6a8326ef884ede9a1b2c510b","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja dwutlenku siarki, dwutlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku siarki, dwutlenku węgla (z obliczeń)","reference":"PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","norm_bases":["PN-ISO 10396:2001","PB-4/2023 wyd. 1 z dn. 12.01.2023 r."],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja dwutlenku siarki, dwutlenku węgla (z obliczeń) PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r. Gazy odlotowe Emisja dwutlenku siarki, dwutlenku wegla (z obliczen) PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of sulphur dioxide, carbon dioxide (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of sulphur dioxide, carbon dioxide (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-ISO 10396:2001 | PB-4/2023 wyd. 1 z dn. 12.01.2023 r.","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c510c","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(5,0 – 1500) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres (5,0 – 1500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres (5,0 – 1500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla\nZakres (5,0 – 1500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1500) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 15058:2017-04","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(5,0 – 1500) mg/m3"}],"search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","technique_zh":"非分散红外光谱法（NDIR）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c510d","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja tlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) PN-EN 15058:2017-04 Gazy odlotowe Emisja tlenku wegla (z obliczen) PN-EN 15058:2017-04","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Carbon monoxide emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 15058:2017-04","test_object_en":"Waste gases","search_zh":"废气 一氧化碳排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 15058:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a8326ef884ede9a1b2c510e","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, tlenków azotu","parameters":[{"name":"NO","range":"(4,0 – 1100) mg/m3"},{"name":"NOx","range":"(5,0 – 1680) mg/m³"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (4,0 – 1100) mg/m3\nNOx (5,0 – 1680) mg/m³\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (4,0 – 1100) mg/m3\nNOx (5,0 – 1680) mg/m³\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (4,0 – 1100) mg/m3\nNOx (5,0 – 1680) mg/m³\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters_en":[{"name":"NO","range":"(4,0 – 1100) mg/m3"},{"name":"NOx","range":"(5,0 – 1680) mg/m³"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method (CLD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law NO NOx PN-EN 14792:2017-04","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Waste gases","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法（CLD） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 NO NOx PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(4,0 – 1100) mg/m3"},{"name":"NOx","range":"(5,0 – 1680) mg/m³"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"化学发光法（CLD）","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a8326ef884ede9a1b2c510f","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja tlenków azotu (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja tlenków azotu (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja tlenków azotu (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja tlenkow azotu (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of nitrogen oxides (NO and NO2 calculated as NO2) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of nitrogen oxides (NO and NO2 calculated as NO2) (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14792:2017-04","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14792:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c5110","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4,0 – 40) %"},{"name":"Zawartość pary wodnej","range":"(29 – 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 – 40) %\nZawartość pary wodnej (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 – 40) %\nZawartość pary wodnej (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nZakres (4,0 – 40) %\nZawartosc pary wodnej (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4,0 – 40) %"},{"name":"Water vapour content","range":"(29 – 250) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Water vapour content PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(4,0 – 40) %"},{"name":"水蒸气含量","range":"(29 – 250) g/m3"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 水蒸气含量 PN-EN 14790:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a8326ef884ede9a1b2c5111","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":"Metoda z zastosowaniem filtrów płaskich i roztworów pochłaniających","techniques":["Metoda z zastosowaniem filtrów płaskich i roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V\nMetoda z zastosowaniem filtrów płaskich i roztworów pochłaniających","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V\nMetoda z zastosowaniem filtrów płaskich i roztworów pochłaniających PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V\nMetoda z zastosowaniem filtrow plaskich i roztworow pochlaniajacych PN-EN 14385:2025-05","categories":["materials"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Method using flat filters and absorbing solutions Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2025-05","technique_en":"Method using flat filters and absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2025-05","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V"},{"_id":"6a8326ef884ede9a1b2c5112","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025-05","categories":["materials","environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2025-05","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a8326ef884ede9a1b2c5113","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":"Metoda z zastosowaniem filtrów płaskich i roztworów pochłaniających","techniques":["Metoda z zastosowaniem filtrów płaskich i roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej\nMetoda z zastosowaniem filtrów płaskich i roztworów pochłaniających","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej\nMetoda z zastosowaniem filtrów płaskich i roztworów pochłaniających PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej\nMetoda z zastosowaniem filtrow plaskich i roztworow pochlaniajacych PN-EN 13211+AC:2006","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of total mercury concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of total mercury concentration Method using flat filters and absorbing solutions Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","technique_en":"Method using flat filters and absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 总汞浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞浓度测定采样"},{"_id":"6a8326ef884ede9a1b2c5114","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mercury emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Total mercury emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a8326ef884ede9a1b2c5115","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia HF","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia HF","reference":"ISO 15713:2006 | CEN/TS 17340:2020","norm_bases":["ISO 15713:2006","CEN/TS 17340:2020"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia HF ISO 15713:2006 | CEN/TS 17340:2020 Gazy odlotowe Pobieranie probek do oznaczania stezenia HF ISO 15713:2006 | CEN/TS 17340:2020","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of HF concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of HF concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006 | CEN/TS 17340:2020","test_object_en":"Waste gases","search_zh":"废气 用于测定 HF 浓度的采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006 | CEN/TS 17340:2020","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定 HF 浓度的采样"},{"_id":"6a8326ef884ede9a1b2c5116","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006 | CEN/TS 17340:2020","norm_bases":["ISO 15713:2006","CEN/TS 17340:2020"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 | CEN/TS 17340:2020 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006 | CEN/TS 17340:2020","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HF emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases HF emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006 | CEN/TS 17340:2020","test_object_en":"Waste gases","search_zh":"废气 HF 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006 | CEN/TS 17340:2020","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a8326ef884ede9a1b2c5117","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie ditlenku siarki","parameters":[{"name":"Zakres","range":"(2,78 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie ditlenku siarki\nZakres (2,78 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie ditlenku siarki\nZakres (2,78 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie ditlenku siarki\nZakres (2,78 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphur dioxide concentration","parameters_en":[{"name":"Range","range":"(2,78 – 2000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sulphur dioxide concentration Thoron method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,78 – 2000) mg/m3"}],"search_zh":"废气 二氧化硫浓度 钍射气法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14791:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"钍射气法","methodology_zh":"二氧化硫浓度"},{"_id":"6a8326ef884ede9a1b2c5118","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases SO2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 SO2 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a8326ef884ede9a1b2c5119","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(1,5 – 20) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO2\nZakres (1,5 – 20) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie CO2\nZakres (1,5 – 20) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Gazy odlotowe Stezenie CO2\nZakres (1,5 – 20) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(1,5 – 20) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO2 concentration Non-dispersive infrared spectrometry (NDIR) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range ISO 12039:2019","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,5 – 20) %"}],"search_zh":"废气 CO2 浓度 非分散红外光谱法（NDIR） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 ISO 12039:2019","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO2 浓度"},{"_id":"6a8326ef884ede9a1b2c511a","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO2 (z obliczeń)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) ISO 12039:2019 Gazy odlotowe Emisja CO2 (z obliczen) ISO 12039:2019","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 12039:2019","test_object_en":"Waste gases","search_zh":"废气 CO2 排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 12039:2019","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a8326ef884ede9a1b2c511b","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania chlorowodoru","parameters":[],"technique":"Metoda z zastosowaniem roztworów pochłaniających","techniques":["Metoda z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania chlorowodoru\nMetoda z zastosowaniem roztworów pochłaniających","reference":"PN-EN-1911:2011","norm_bases":["PN-EN-1911:2011"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania chlorowodoru\nMetoda z zastosowaniem roztworów pochłaniających PN-EN-1911:2011 Gazy odlotowe Pobieranie probek do oznaczania chlorowodoru\nMetoda z zastosowaniem roztworow pochlaniajacych PN-EN-1911:2011","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of hydrogen chloride","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for the determination of hydrogen chloride Method using absorbing solutions Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN-1911:2011","technique_en":"Method using absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 用于测定氯化氢的采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN-1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定氯化氢的采样"},{"_id":"6a8326ef884ede9a1b2c511c","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja chlorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"PN-EN-1911:2011","norm_bases":["PN-EN-1911:2011"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja chlorowodoru (z obliczeń) PN-EN-1911:2011 Gazy odlotowe Emisja chlorowodoru (z obliczen) PN-EN-1911:2011","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen chloride emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN-1911:2011","test_object_en":"Waste gases","search_zh":"废气 氯化氢排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN-1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a8326ef884ede9a1b2c511d","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":"Metoda z zastosowaniem węgla aktywnego","techniques":["Metoda z zastosowaniem węgla aktywnego"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda z zastosowaniem węgla aktywnego","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda z zastosowaniem węgla aktywnego PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych\nMetoda z zastosowaniem wegla aktywnego PN-EN 13649:2005","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Method using activated carbon Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","technique_en":"Method using activated carbon","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a8326ef884ede9a1b2c511e","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8326ef884ede9a1b2c511f","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczenia stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of ammonia concentration","search_en":"Waste gases Sampling for the determination of ammonia concentration PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 用于测定氨浓度的采样 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"用于测定氨浓度的采样"},{"_id":"6a8326ef884ede9a1b2c5120","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia emission (calculated)","search_en":"Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨排放量（计算值） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨排放量（计算值）"},{"_id":"6a8326ef884ede9a1b2c5121","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia pyłu PM 2,5 i PM 10","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia pyłu PM 2,5 i PM 10","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia pyłu PM 2,5 i PM 10 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczenia stezenia pylu PM 2,5 i PM 10 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of PM 2,5 and PM 10 dust concentration","search_en":"Waste gases Sampling for determination of PM 2,5 and PM 10 dust concentration PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气"},{"_id":"6a8326ef884ede9a1b2c5122","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu PM 2,5 i PM 10 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu PM 2,5 i PM 10 (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu PM 2,5 i PM 10 (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu PM 2,5 i PM 10 (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PM 2,5 and PM 10 dust emission (calculated)","search_en":"Waste gases PM 2,5 and PM 10 dust emission (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 PM 2,5 与 PM 10 粉尘排放（由计算得出） PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"PM 2,5 与 PM 10 粉尘排放（由计算得出）"},{"_id":"6a8326ef884ede9a1b2c5123","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(35 – 135) dB"},{"name":"Szczytowy poziom dźwięku C","range":"(50 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (35 – 135) dB\nSzczytowy poziom dźwięku C (50 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (35 – 135) dB\nSzczytowy poziom dźwięku C (50 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (35 – 135) dB\nSzczytowy poziom dzwieku C (50 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – pkt. 10 i Strategie 3 – pkt. 11","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(35 – 135) dB"},{"name":"C-weighted peak sound pressure level","range":"(50 – 138) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(35 – 135) dB"},{"name":"C 计权峰值声级","range":"(50 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a8326ef884ede9a1b2c5124","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: (z obliczeń)","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"tygodnia pracy"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: (z obliczeń)\nZakres:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do: (z obliczeń)\nZakres:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do: (z obliczen)\nZakres:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – pkt. 10 i Strategie 3 – pkt. 11","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level normalised to: (calculated)","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"tygodnia pracy"}],"search_en":"Workplace environment – noise Noise exposure level normalised to: (calculated) an 8-hour daily working time PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","test_object_en":"Workplace environment – noise","search_zh":"工作场所环境 — 噪声 8 小时日工作时间 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","test_object_zh":"工作场所环境 — 噪声","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"tygodnia pracy"}]},{"_id":"6a8326ef884ede9a1b2c5125","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A, LAeq","parameters":[{"name":"Zakres","range":"(20 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A, LAeq\nZakres (20 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A, LAeq\nZakres (20 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A, LAeq\nZakres (20 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wylaczeniem pkt. II.1 z wylaczeniem pkt. F","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level, LAeq","parameters_en":[{"name":"Range","range":"(20 – 135) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level, LAeq Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","parameters_zh":[{"name":"范围","range":"(20 – 135) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a8326ef884ede9a1b2c5126","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wylaczeniem pkt. II.1 z wylaczeniem pkt. F","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem pkt. II.1 z wyłączeniem pkt. F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a8326ef884ede9a1b2c5127","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(20 – 134) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (20 – 134) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4","norm_bases":["PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Równoważny poziom dźwięku A\nZakres (20 – 134) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4 Maszyny i urzadzenia – halas Rownowazny poziom dzwieku A\nZakres (20 – 134) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 + Ap1:2017-09 z wylaczeniem pkt. 8.4","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(20 – 134) dB"}],"search_en":"Machinery and equipment – noise A-weighted equivalent sound pressure level Direct measurement method Range PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(20 – 134) dB"}],"search_zh":"机器与设备 – 噪声 A 计权等效声级 直接测量法 范围 PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a8326ef884ede9a1b2c5128","lab_id":"69ad52a3de79e566650fba2b","country":"PL","accr_number":"AB 1880","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4","norm_bases":["PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4"],"lab_section":"Laboratorium Ochrony Środowiska LABOTECH; Aleja Walentego Roździeńskiego 188E, 40-203 Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 + Ap1:2017-09 z wylaczeniem pkt. 8.4","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3746:2011 + Ap1:2017-09 z wyłączeniem pkt. 8.4","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"}],"has_pdf":true}