🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 188 • Warszawa, Poland • 76 methods

Water & wastewaterEnvironment

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 188 (Warszawa, Poland). Its accreditation scope covers 76 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, Wastewater, Wastewater, Water, Soil. Most frequently used techniques: Continuous flow analysis (CFA) with spectrophotometric detection, Electrochemical method, Potentiometric method.

At a glance

  • Accreditation number: PCA AB 188
  • Methods in scope: 76
  • Types of test objects: 12
  • Techniques used: 18
  • City: Warszawa, Poland
Accreditation number
AB 188
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KATOWICACH
City
Warszawa, Poland

What this laboratory tests (12)

Analytical techniques used (18)

Accreditation scope — test methods (76)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Wastewater pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
2 Water, Wastewater Electrical conductivity
Range (80 – 20000) μS/cm
Conductometric method PN-EN 27888:1999
3 Water, Wastewater Biochemical oxygen demand
BOD5 Range (5,0 – 1000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
4 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
5 Water, Wastewater Chemical oxygen demand
COD-Cr Range (30 – 10000) mg/l O2
Titrimetric method PN-ISO 6060:2006
6 Water, Wastewater Nitrite nitrogen concentration
Range (0,003 – 1) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
7 Water, Wastewater Nitrate nitrogen concentration
Range (0,10 – 300) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012
8 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,20 – 1000) mg/l
Spectrophotometric method PB-14/KA wydanie 2 z dnia 25.04.2025
9 Water, Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PB-13/KA wydanie 2 z dnia 25.04.2025
10 Water, Wastewater Total nitrogen concentration (calculated) PB-15/KA wydanie 2 z dnia 25.04.2025
11 Water, Wastewater Phosphate concentration
Range (0,016 – 4) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
12 Water, Wastewater Chloride concentration
Range (1,0 – 10000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
13 Water, Wastewater Sulfate concentration
Range (1,0 – 1500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
14 Water, Wastewater Total dissolved solids (TDS)
Range (100 – 25 000) mg/l
Gravimetric method PN-EN 15216:2022-03
15 Water, Wastewater Total suspended solids (TSS)
Range (4,0 – 7000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
16 Water, Wastewater Benzene and homologues concentration
benzene toluene o-xylene ethylbenzene Range (2,5 – 1200) μg/l (m+p)xylene Range (5,0 – 2400) μg/l
Gas chromatography with flame ionization detection (GC-FID) PB-76/KA wydanie 2 z dnia 25.04.2025
17 Water, Wastewater Mineral oil index
Range (0,050 – 30) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
18 Water, Wastewater Phenol index
Range (0,003 – 1,0) mg/l
Spectrophotometric method PN-ISO 6439:1994
19 Water, Wastewater Ammonium nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
20 Water, Wastewater Total and free cyanide concentration
Range (0,005 – 50) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 14403-2:2012
21 Water, Wastewater Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012
22 Water, Wastewater Concentration of anionic surfactants
Range (0,05 – 20) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PB-27/KA wydanie 2 z dnia 25.04.2025
23 Water Mercury concentration
Range (0,015 – 0,100) μg/l
Cold vapour atomic fluorescence spectrometry (CVAFS) PN-EN ISO 17852:2009
24 Water Dissolved oxygen concentration
Range (1,0 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013
25 Water Chemical oxygen demand
COD-Cr Range (3 – 200) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
26 Water Element concentration
arsenic (0,050 – 5) mg/l barium (0,010 – 5) mg/l boron (0,080 – 5) mg/l aluminium (0,050 – 5) mg/l cadmium (0,005 – 5) mg/l calcium (5,0 – 200) mg/l chromium (0,003 – 5) mg/l cobalt (0,005 – 5) mg/l copper (0,005 – 5) mg/l iron (0,020 – 5) mg/l lead (0,010 – 5) mg/l magnesium (2,0 – 50) mg/l manganese (0,020 – 5) mg/l molybdenum (0,005 – 5) mg/l nickel (0,005 – 5) mg/l potassium (2,0 – 50) mg/l selenium (0,050 – 5) mg/l silver (0,005 – 5) mg/l sodium (2,0 – 50) mg/l titanium (0,010 – 5) mg/l vanadium (0,010 – 5) mg/l zinc (0,010 – 5) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
27 Water Ammonium nitrogen concentration
Range (0,04 – 10) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
28 Water Total phosphorus concentration
Range (0,03 – 10) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
29 Water Concentration of polycyclic
aromatic hydrocarbons (PAH) naphthalene acenaphthene fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene benzo(ghi)perylene indeno(1,2,3,-cd)pyrene Range (0,002 – 0,2) μg/l
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
30 Wastewater Total phosphorus concentration
Range (0,03 – 30) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
31 Wastewater Element concentration
arsenic (0,050 – 5) mg/l barium (0,010 – 5) mg/l boron (0,080 – 5) mg/l aluminium (0,050 – 5) mg/l cadmium (0,005 – 5) mg/l chromium (0,003 – 5) mg/l cobalt (0,005 – 5) mg/l copper (0,005 – 5) mg/l iron (0,020 – 5) mg/l lead (0,010 – 5) mg/l manganese (0,020 – 5) mg/l molybdenum (0,005 – 5) mg/l nickel (0,005 – 5) mg/l selenium (0,050 – 5) mg/l silver (0,005 – 5) mg/l titanium (0,010 – 5) mg/l vanadium (0,010 – 5) mg/l zinc (0,010 – 5) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
32 Wastewater Chemical oxygen demand
COD-Cr Range (10 – 1500) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
33 Wastewater Ammonium nitrogen concentration
Range (0,20 – 10) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
34 Soil Aromatic hydrocarbons (BTEX) concentration
benzene (0,250 – 100) mg/kg toluene (0,250 – 100) mg/kg ethylbenzene (0,250 – 100) mg/kg o-xylene (0,250 – 100) mg/kg (m+p)-xylene (0,500 – 200) mg/kg
Gas chromatography with flame ionization detection (GC-FID) PB-69/KA wydanie 1 z dnia 26.03.2024
35 Soil Sum of hydrocarbons C6-C12 (gasoline content)
Range (1 – 500) mg/kg
Gas chromatography with flame ionization detection (GC-FID) PB-91/KA wydanie 1 z dnia 26.03.2024
36 Soil Sum of hydrocarbons C12-C35 (mineral oil content)
Range (40-10000) mg/kg
Gas chromatography with flame ionization detection (GC-FID) PB-91/KA wydanie 1 z dnia 26.03.2024
37 Water, Wastewater Electrical conductivity
Range 25 μS/cm – 10 mS/cm
Conductometric method PN-EN 27888:1999
38 Water, Wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
39 Water, Wastewater Total suspended solids (TSS)
Range (5,0 – 4000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
40 Water, Wastewater Total dissolved solids (TDS)
Range (100 – 5000) mg/l
Gravimetric method PN-EN 15216:2022-03
41 Water, Wastewater Chemical oxygen demand
COD-Cr Range (20 – 2000) mg/l O2
Titrimetric method PB-7/KA wydanie 2 z dnia 25.04.2025
42 Water, Wastewater Biochemical oxygen demand
BOD5 Range (6 – 1000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
43 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
44 Water, Wastewater Total organic carbon concentration (TOC)
Range (1,0 – 700) mg/l
Spectrometry method in the infrared range (IR) PN-EN 1484:1999
45 Water, Wastewater Nitrite nitrogen concentration
Range (0,010 – 300) mg/l
Flow analysis (FIA) with spectrophotometric detection PN-EN ISO 13395:2001
46 Water, Wastewater Total phosphorus concentration
Range (0,03 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
47 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,70 – 250) mg/l
Titrimetric method PB-4/KA wydanie 2 z dnia 25.04.2025
48 Water, Wastewater Total nitrogen concentration (calculated) PB-5/KA wydanie 2 z dnia 25.04.2025
49 Water, Wastewater Phenol index
Range (0,050 – 50) mg/l
Spectrophotometric method PN-ISO 6439:1994 Metoda B
50 Water, Wastewater Free cyanide concentration
Range (0,10 – 100) mg/l
Spectrophotometric method PN-80/C-04603/01
51 Water, Wastewater Concentration of substances extractable with petroleum ether
Range (20 – 200) mg/l
Gravimetric method PB-6/KA wydanie 2 z dnia 25.04.2025
52 Water, Wastewater Element concentrations:
zinc (0,010 – 10) mg/l copper (0,010 – 10) mg/l cadmium (0,010 – 10) mg/l nickel (0,010 – 10) mg/l lead (0,010 – 10) mg/l manganese (0,010 – 10) mg/l iron (0,010 – 10) mg/l chromium (0,010 – 10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PB-18/KA wydanie 2 z dnia 25.04.2025
53 Water, Wastewater Anion concentrations:
fluorides (0,3 – 1000) mg/l chlorides (1 – 1000) mg/l nitrate nitrogen (0,3 – 1000) mg/l sulfates (2 – 1000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
54 Wastewater Mercury concentration
Range (0,001 – 0,1) mg/l
Atomic absorption spectrometry with amalgamation technique PB-19/KA wydanie 2 z dnia 25.04.2025
55 Soil Dry matter/water content
Range (5,0 – 95) %
Gravimetric method PN-ISO 11465:1999
56 Soil pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
57 Surface waters Sampling for chemical, physical testing
Temperature of the collected water sample Range (1,0 – 25,0) °C
Manual method PN-EN ISO 5667-6:2016-12 | PB-17/KA wydanie 2 z dnia 25.04.2025
58 Surface waters Dissolved oxygen concentration
Range (1,0 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
59 Surface waters pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
60 Surface waters Electrical conductivity
Range (100 – 10 000) μS/cm
Conductometric method PN-EN 27888:1999
61 Surface waters (dam reservoirs) Sampling for chemical and physical testing Temperature of the water sample taken
Range (1,0 – 25,0) °C
PN-ISO 5667-4:2017-10 | PB-17/KA wydanie 2 z dnia 25.04.2025
62 Surface waters (dam reservoirs) pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
63 Surface waters (dam reservoirs) Electrical conductivity
Range (100 - 10 000) μS/cm
Conductometric method PN-EN 27888:1999
64 Groundwater Sampling for chemical and physical testing Measurement of the temperature of the water sample
Range (1,0 – 25,0) oC
PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3 | PB-17/KA wydanie 2 z dnia 25.04.2025
65 Groundwater Dissolved oxygen concentration
Range (1,0 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
66 Groundwater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
67 Groundwater Electrical conductivity
Range (100 – 10 000) μS/cm
Conductometric method PN-EN 27888:1999
68 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (1,0 – 25,0) °C
Manual and automatic method PN-ISO 5667-10:2021-11 | PB-17/KA wydanie 2 z dnia 25.04.2025
69 Wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
70 Soils Sampling for physical and chemical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
71 Sewage sludge Sampling for physical and chemical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7
72 Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023
73 General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level
Range (30 – 130) dB
Direct measurement method Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H
74 General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H
75 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (30 – 130) dB
Direct measurement method Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F
76 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F

Reference standards (51)

PB-11/CLB wydanie 1 z dnia 25.09.2023
PB-13/KA wydanie 2 z dnia 25.04.2025
PB-14/KA wydanie 2 z dnia 25.04.2025
PB-15/KA wydanie 2 z dnia 25.04.2025
PB-17/KA wydanie 2 z dnia 25.04.2025
PB-18/KA wydanie 2 z dnia 25.04.2025
PB-19/KA wydanie 2 z dnia 25.04.2025
PB-27/KA wydanie 2 z dnia 25.04.2025
PB-4/KA wydanie 2 z dnia 25.04.2025
PB-5/KA wydanie 2 z dnia 25.04.2025
PB-6/KA wydanie 2 z dnia 25.04.2025
PB-69/KA wydanie 1 z dnia 26.03.2024
PB-7/KA wydanie 2 z dnia 25.04.2025
PB-76/KA wydanie 2 z dnia 25.04.2025
PB-91/KA wydanie 1 z dnia 26.03.2024
PN-80/C-04603/01
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009 + AC:2012
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11732:2007
PN-EN ISO 11885:2009
PN-EN ISO 13395:2001
PN-EN ISO 14403-2:2012
PN-EN ISO 15681-2:2019-02
PN-EN ISO 17852:2009
PN-EN ISO 17993:2005
PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3
PN-ISO 5667-4:2017-10
PN-ISO 6060:2006
PN-ISO 6439:1994
PN-ISO 6439:1994 Metoda B
Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H