{"lab":{"_id":"69ad52a3de79e566650fb161","accr_number":"AB 188","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KATOWICACH","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":76,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_188.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w katowicach water pharma electronics other food materials environment metrology","status":"active","updated_at":"2026-03-08T14:51:00.599Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:00.599Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"low","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"C/31/P","pl":"Badania chemiczne i pobieranie próbek gleby","en":"Chemical tests and sampling of soil"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) of general environment (physical factors - noise)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"P/31; P/32","pl":"Pobieranie próbek gleby, osadów ściekowych","en":"sampling of soil, sediment"},{"codes":"N/31/P","pl":"Badanie właściwości fizycznych i pobieranie próbek gleby","en":"Tests of physical properties and sampling of soil"}],"issue":{"no":"27","date":"24.06.2025"},"parse_date":"2026-07-20T07:09:57.363Z","parse_source":"script-pdfplumber","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":66,"environment":10,"materials":3,"petro":2,"other":1},"category_scores":{"water":53.12,"environment":1.22,"materials":0.11,"petro":0.05,"other":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9c5f1c10c8ce826035d","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826035e","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(80 – 20000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(80 – 20000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (80 – 20000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (80 – 20000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (80 – 20000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(80 – 20000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826035f","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(5,0 – 1000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(5,0 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (5,0 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (5,0 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (5,0 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(5,0 – 1000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260360","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260361","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(30 – 10000) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(30 – 10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method COD-Cr Range PN-ISO 6060:2006","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(30 – 10000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 化学需氧量（COD-Cr） 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c5f1c10c8ce8260362","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,003 – 1) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,003 – 1) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,003 – 1) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,003 – 1) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,003 – 1) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,003 – 1) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260363","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 300) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,10 – 300) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009 + AC:2012","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 300) mg/l"}],"search_zh":"水、污水 硝态氮浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260364","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,20 – 1000) mg/l\nMetoda spektrofotometryczna","reference":"PB-14/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-14/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,20 – 1000) mg/l\nMetoda spektrofotometryczna PB-14/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,20 – 1000) mg/l\nMetoda spektrofotometryczna PB-14/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PB-14/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 分光光度法 范围 PB-14/KA wydanie 2 z dnia 25.04.2025","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260365","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PB-13/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-13/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PB-13/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PB-13/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PB-13/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PB-13/KA wydanie 2 z dnia 25.04.2025","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260366","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-15/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-15/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-15/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-15/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-15/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-15/KA wydanie 2 z dnia 25.04.2025","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260367","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforanów","methodology_en":"Phosphate concentration","parameters":[{"name":"Zakres","range":"(0,016 – 4) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,016 – 4) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie fosforanów\nZakres (0,016 – 4) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforanów\nZakres (0,016 – 4) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, Scieki Stezenie fosforanow\nZakres (0,016 – 4) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phosphate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","parameters_zh":[{"name":"范围","range":"(0,016 – 4) mg/l"}],"search_zh":"水、污水 磷酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"磷酸盐浓度"},{"_id":"6a5dc9c5f1c10c8ce8260368","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(1,0 – 10000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 10000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (1,0 – 10000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (1,0 – 10000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie chlorkow\nZakres (1,0 – 10000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 10000) mg/l"}],"search_zh":"水、污水 氯化物浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260369","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1500) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1500) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (1,0 – 1500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (1,0 – 1500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie siarczanow\nZakres (1,0 – 1500) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1500) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826036a","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(100 – 25 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(100 – 25 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (100 – 25 000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (100 – 25 000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Calkowite substancje rozpuszczone (TDS)\nZakres (100 – 25 000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(100 – 25 000) mg/l"}],"search_zh":"水、污水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a5dc9c5f1c10c8ce826036b","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(4,0 – 7000) mg/l"}],"parameters_en":[{"name":"Range","range":"(4,0 – 7000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (4,0 – 7000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (4,0 – 7000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (4,0 – 7000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(4,0 – 7000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826036c","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie benzenu i homologów","methodology_en":"Benzene and homologues concentration","parameters":[{"name":"benzen"},{"name":"toluen"},{"name":"o-ksylen"},{"name":"etylobenzen"},{"name":"Zakres","range":"(2,5 – 1200) μg/l"},{"name":"(m+p)ksylen"},{"name":"Zakres","range":"(5,0 – 2400) μg/l"}],"parameters_en":[{"name":"benzene"},{"name":"toluene"},{"name":"o-xylene"},{"name":"ethylbenzene"},{"name":"Range","range":"(2,5 – 1200) μg/l"},{"name":"(m+p)xylene"},{"name":"Range","range":"(5,0 – 2400) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie benzenu i homologów\nZakres:\nbenzen\ntoluen\no-ksylen\netylobenzen\nZakres (2,5 – 1200) μg/l\n(m+p)ksylen\nZakres (5,0 – 2400) μg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-76/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-76/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie benzenu i homologów\nZakres:\nbenzen\ntoluen\no-ksylen\netylobenzen\nZakres (2,5 – 1200) μg/l\n(m+p)ksylen\nZakres (5,0 – 2400) μg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-76/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie benzenu i homologow\nZakres:\nbenzen\ntoluen\no-ksylen\netylobenzen\nZakres (2,5 – 1200) μg/l\n(m+p)ksylen\nZakres (5,0 – 2400) μg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-76/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Benzene and homologues concentration Gas chromatography with flame ionization detection (GC-FID) benzene toluene o-xylene ethylbenzene Range (m+p)xylene Range PB-76/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"苯"},{"name":"甲苯"},{"name":"邻二甲苯"},{"name":"乙苯"},{"name":"范围","range":"(2,5 – 1200) μg/l"},{"name":"(m+p)ksylen"},{"name":"范围","range":"(5,0 – 2400) μg/l"}],"search_zh":"水、污水 气相色谱-氢火焰离子化检测法（GC-FID） 苯 甲苯 邻二甲苯 乙苯 范围 范围 PB-76/KA wydanie 2 z dnia 25.04.2025","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826036d","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,050 – 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 30) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,050 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks oleju mineralnego\nZakres (0,050 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki Indeks oleju mineralnego\nZakres (0,050 – 30) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,050 – 30) mg/l"}],"search_zh":"水、污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9c5f1c10c8ce826036e","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,003 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,003 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,003 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,003 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, Scieki Indeks fenolowy\nZakres (0,003 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","parameters_zh":[{"name":"范围","range":"(0,003 – 1,0) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a5dc9c5f1c10c8ce826036f","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260370","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie cyjanków ogólnych i wolnych","methodology_en":"Total and free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,005 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie cyjanków ogólnych i wolnych\nZakres (0,005 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie cyjanków ogólnych i wolnych\nZakres (0,005 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda, Scieki Stezenie cyjankow ogolnych i wolnych\nZakres (0,005 – 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total and free cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14403-2:2012","parameters_zh":[{"name":"范围","range":"(0,005 – 50) mg/l"}],"search_zh":"水、污水 总氰化物与游离氰化物浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"总氰化物与游离氰化物浓度"},{"_id":"6a5dc9c5f1c10c8ce8260371","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie cyjanków związanych (z obliczeń)","methodology_en":"Combined cyanide concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków związanych (z obliczeń)","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie cyjanków związanych (z obliczeń) PN-EN ISO 14403-2:2012 Woda, Scieki Stezenie cyjankow zwiazanych (z obliczen) PN-EN ISO 14403-2:2012","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012","search_zh":"水、污水 络合氰化物浓度（由计算得出） PN-EN ISO 14403-2:2012","test_object_zh":"水、污水","methodology_zh":"络合氰化物浓度（由计算得出）"},{"_id":"6a5dc9c5f1c10c8ce8260372","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji powierzchniowoczynnych anionowych","methodology_en":"Concentration of anionic surfactants","parameters":[{"name":"Zakres","range":"(0,05 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 20) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie substancji powierzchniowoczynnych anionowych\nZakres (0,05 – 20) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-27/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-27/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji powierzchniowoczynnych anionowych\nZakres (0,05 – 20) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-27/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie substancji powierzchniowoczynnych anionowych\nZakres (0,05 – 20) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-27/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of anionic surfactants Continuous flow analysis (CFA) with spectrophotometric detection Range PB-27/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"范围","range":"(0,05 – 20) mg/l"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 范围 PB-27/KA wydanie 2 z dnia 25.04.2025","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260373","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,015 – 0,100) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,015 – 0,100) μg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)"],"technique_en":"Cold vapour atomic fluorescence spectrometry (CVAFS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,015 – 0,100) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci\nZakres (0,015 – 0,100) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Woda Stezenie rteci\nZakres (0,015 – 0,100) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Mercury concentration Cold vapour atomic fluorescence spectrometry (CVAFS) Range PN-EN ISO 17852:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 0,100) μg/l"}],"search_zh":"水 汞浓度 冷蒸气原子荧光光谱法（CVAFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水","technique_zh":"冷蒸气原子荧光光谱法（CVAFS）"},{"_id":"6a5dc9c5f1c10c8ce8260374","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013","norm_bases":["PN-EN ISO 5814:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013 Woda Stezenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9c5f1c10c8ce8260375","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(3 – 200) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(3 – 200) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (3 – 200) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (3 – 200) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (3 – 200) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(3 – 200) mg/l O2"}],"search_zh":"水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c5f1c10c8ce8260376","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"arsen","range":"(0,050 – 5) mg/l"},{"name":"bar","range":"(0,010 – 5) mg/l"},{"name":"bor","range":"(0,080 – 5) mg/l"},{"name":"glin","range":"(0,050 – 5) mg/l"},{"name":"kadm","range":"(0,005 – 5) mg/l"},{"name":"wapń","range":"(5,0 – 200) mg/l"},{"name":"chrom","range":"(0,003 – 5) mg/l"},{"name":"kobalt","range":"(0,005 – 5) mg/l"},{"name":"miedź","range":"(0,005 – 5) mg/l"},{"name":"żelazo","range":"(0,020 – 5) mg/l"},{"name":"ołów","range":"(0,010 – 5) mg/l"},{"name":"magnez","range":"(2,0 – 50) mg/l"},{"name":"mangan","range":"(0,020 – 5) mg/l"},{"name":"molibden","range":"(0,005 – 5) mg/l"},{"name":"nikiel","range":"(0,005 – 5) mg/l"},{"name":"potas","range":"(2,0 – 50) mg/l"},{"name":"selen","range":"(0,050 – 5) mg/l"},{"name":"srebro","range":"(0,005 – 5) mg/l"},{"name":"sód","range":"(2,0 – 50) mg/l"},{"name":"tytan","range":"(0,010 – 5) mg/l"},{"name":"wanad","range":"(0,010 – 5) mg/l"},{"name":"cynk","range":"(0,010 – 5) mg/l"}],"parameters_en":[{"name":"arsenic","range":"(0,050 – 5) mg/l"},{"name":"barium","range":"(0,010 – 5) mg/l"},{"name":"boron","range":"(0,080 – 5) mg/l"},{"name":"aluminium","range":"(0,050 – 5) mg/l"},{"name":"cadmium","range":"(0,005 – 5) mg/l"},{"name":"calcium","range":"(5,0 – 200) mg/l"},{"name":"chromium","range":"(0,003 – 5) mg/l"},{"name":"cobalt","range":"(0,005 – 5) mg/l"},{"name":"copper","range":"(0,005 – 5) mg/l"},{"name":"iron","range":"(0,020 – 5) mg/l"},{"name":"lead","range":"(0,010 – 5) mg/l"},{"name":"magnesium","range":"(2,0 – 50) mg/l"},{"name":"manganese","range":"(0,020 – 5) mg/l"},{"name":"molybdenum","range":"(0,005 – 5) mg/l"},{"name":"nickel","range":"(0,005 – 5) mg/l"},{"name":"potassium","range":"(2,0 – 50) mg/l"},{"name":"selenium","range":"(0,050 – 5) mg/l"},{"name":"silver","range":"(0,005 – 5) mg/l"},{"name":"sodium","range":"(2,0 – 50) mg/l"},{"name":"titanium","range":"(0,010 – 5) mg/l"},{"name":"vanadium","range":"(0,010 – 5) mg/l"},{"name":"zinc","range":"(0,010 – 5) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\narsen (0,050 – 5) mg/l\nbar (0,010 – 5) mg/l\nbor (0,080 – 5) mg/l\nglin (0,050 – 5) mg/l\nkadm (0,005 – 5) mg/l\nwapń (5,0 – 200) mg/l\nchrom (0,003 – 5) mg/l\nkobalt (0,005 – 5) mg/l\nmiedź (0,005 – 5) mg/l\nżelazo (0,020 – 5) mg/l\nołów (0,010 – 5) mg/l\nmagnez (2,0 – 50) mg/l\nmangan (0,020 – 5) mg/l\nmolibden (0,005 – 5) mg/l\nnikiel (0,005 – 5) mg/l\npotas (2,0 – 50) mg/l\nselen (0,050 – 5) mg/l\nsrebro (0,005 – 5) mg/l\nsód (2,0 – 50) mg/l\ntytan (0,010 – 5) mg/l\nwanad (0,010 – 5) mg/l\ncynk (0,010 – 5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pierwiastków\nZakres:\narsen (0,050 – 5) mg/l\nbar (0,010 – 5) mg/l\nbor (0,080 – 5) mg/l\nglin (0,050 – 5) mg/l\nkadm (0,005 – 5) mg/l\nwapń (5,0 – 200) mg/l\nchrom (0,003 – 5) mg/l\nkobalt (0,005 – 5) mg/l\nmiedź (0,005 – 5) mg/l\nżelazo (0,020 – 5) mg/l\nołów (0,010 – 5) mg/l\nmagnez (2,0 – 50) mg/l\nmangan (0,020 – 5) mg/l\nmolibden (0,005 – 5) mg/l\nnikiel (0,005 – 5) mg/l\npotas (2,0 – 50) mg/l\nselen (0,050 – 5) mg/l\nsrebro (0,005 – 5) mg/l\nsód (2,0 – 50) mg/l\ntytan (0,010 – 5) mg/l\nwanad (0,010 – 5) mg/l\ncynk (0,010 – 5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\narsen (0,050 – 5) mg/l\nbar (0,010 – 5) mg/l\nbor (0,080 – 5) mg/l\nglin (0,050 – 5) mg/l\nkadm (0,005 – 5) mg/l\nwapn (5,0 – 200) mg/l\nchrom (0,003 – 5) mg/l\nkobalt (0,005 – 5) mg/l\nmiedz (0,005 – 5) mg/l\nzelazo (0,020 – 5) mg/l\nolow (0,010 – 5) mg/l\nmagnez (2,0 – 50) mg/l\nmangan (0,020 – 5) mg/l\nmolibden (0,005 – 5) mg/l\nnikiel (0,005 – 5) mg/l\npotas (2,0 – 50) mg/l\nselen (0,050 – 5) mg/l\nsrebro (0,005 – 5) mg/l\nsod (2,0 – 50) mg/l\ntytan (0,010 – 5) mg/l\nwanad (0,010 – 5) mg/l\ncynk (0,010 – 5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic barium boron aluminium cadmium calcium chromium cobalt copper iron lead magnesium manganese molybdenum nickel potassium selenium silver sodium titanium vanadium zinc PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"砷","range":"(0,050 – 5) mg/l"},{"name":"钡","range":"(0,010 – 5) mg/l"},{"name":"硼","range":"(0,080 – 5) mg/l"},{"name":"铝","range":"(0,050 – 5) mg/l"},{"name":"镉","range":"(0,005 – 5) mg/l"},{"name":"钙","range":"(5,0 – 200) mg/l"},{"name":"铬","range":"(0,003 – 5) mg/l"},{"name":"钴","range":"(0,005 – 5) mg/l"},{"name":"铜","range":"(0,005 – 5) mg/l"},{"name":"铁","range":"(0,020 – 5) mg/l"},{"name":"铅","range":"(0,010 – 5) mg/l"},{"name":"镁","range":"(2,0 – 50) mg/l"},{"name":"锰","range":"(0,020 – 5) mg/l"},{"name":"钼","range":"(0,005 – 5) mg/l"},{"name":"镍","range":"(0,005 – 5) mg/l"},{"name":"钾","range":"(2,0 – 50) mg/l"},{"name":"硒","range":"(0,050 – 5) mg/l"},{"name":"银","range":"(0,005 – 5) mg/l"},{"name":"钠","range":"(2,0 – 50) mg/l"},{"name":"钛","range":"(0,010 – 5) mg/l"},{"name":"钒","range":"(0,010 – 5) mg/l"},{"name":"锌","range":"(0,010 – 5) mg/l"}],"search_zh":"水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 钡 硼 铝 镉 钙 铬 钴 铜 铁 铅 镁 锰 钼 镍 钾 硒 银 钠 钛 钒 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水"},{"_id":"6a5dc9c5f1c10c8ce8260377","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu amonowego\nZakres (0,04 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda Stezenie azotu amonowego\nZakres (0,04 – 10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 10) mg/l"}],"search_zh":"水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a5dc9c5f1c10c8ce8260378","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,03 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,03 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,03 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda Stezenie fosforu ogolnego\nZakres (0,03 – 10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 10) mg/l"}],"search_zh":"水 总磷浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a5dc9c5f1c10c8ce8260379","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wielopierścieniowych","methodology_en":"Concentration of polycyclic","parameters":[{"name":"węglowodorów aromatycznych (WWA)"},{"name":"naftalen"},{"name":"acenaften"},{"name":"fluoren"},{"name":"fenantren"},{"name":"antracen"},{"name":"fluoranten"},{"name":"piren"},{"name":"benzo(a)antracen"},{"name":"chryzen"},{"name":"benzo(b)fluoranten"},{"name":"benzo(k)fluoranten"},{"name":"benzo(a)piren"},{"name":"dibenzo(a,h)antracen"},{"name":"benzo(ghi)perylen indeno(1,2,3,-cd)piren"},{"name":"Zakres","range":"(0,002 – 0,2) μg/l"}],"parameters_en":[{"name":"aromatic hydrocarbons (PAH)"},{"name":"naphthalene"},{"name":"acenaphthene"},{"name":"fluorene"},{"name":"phenanthrene"},{"name":"anthracene"},{"name":"fluoranthene"},{"name":"pyrene"},{"name":"benzo(a)anthracene"},{"name":"chrysene"},{"name":"benzo(b)fluoranthene"},{"name":"benzo(k)fluoranthene"},{"name":"benzo(a)pyrene"},{"name":"dibenzo(a,h)anthracene"},{"name":"benzo(ghi)perylene indeno(1,2,3,-cd)pyrene"},{"name":"Range","range":"(0,002 – 0,2) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych\nZakres:\nwęglowodorów aromatycznych (WWA)\nnaftalen\nacenaften\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(ghi)perylen indeno(1,2,3,-cd)piren\nZakres (0,002 – 0,2) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wielopierścieniowych\nZakres:\nwęglowodorów aromatycznych (WWA)\nnaftalen\nacenaften\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(ghi)perylen indeno(1,2,3,-cd)piren\nZakres (0,002 – 0,2) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda Stezenie wielopierscieniowych\nZakres:\nweglowodorow aromatycznych (WWA)\nnaftalen\nacenaften\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(ghi)perylen indeno(1,2,3,-cd)piren\nZakres (0,002 – 0,2) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of polycyclic High-performance liquid chromatography with fluorescence detection (HPLC-FLD) aromatic hydrocarbons (PAH) naphthalene acenaphthene fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene benzo(ghi)perylene indeno(1,2,3,-cd)pyrene Range PN-EN ISO 17993:2005","parameters_zh":[{"name":"多环芳烃（PAH）"},{"name":"萘"},{"name":"苊"},{"name":"芴"},{"name":"菲"},{"name":"蒽"},{"name":"荧蒽"},{"name":"芘"},{"name":"苯并（a）蒽"},{"name":"䓛"},{"name":"苯并（b）荧蒽"},{"name":"苯并（k）荧蒽"},{"name":"苯并（a）芘"},{"name":"二苯并（a,h）蒽"},{"name":"benzo(ghi)perylen indeno(1,2,3,-cd)piren"},{"name":"范围","range":"(0,002 – 0,2) μg/l"}],"search_zh":"水 多环烃浓度 高效液相色谱-荧光检测法（HPLC-FLD） 多环芳烃（PAH） 萘 苊 芴 菲 蒽 荧蒽 芘 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并（a,h）蒽 范围 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水","methodology_zh":"多环烃浓度"},{"_id":"6a5dc9c5f1c10c8ce826037a","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,03 – 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 30) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,03 – 30) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,03 – 30) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Scieki Stezenie fosforu ogolnego\nZakres (0,03 – 30) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 30) mg/l"}],"search_zh":"污水 总磷浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a5dc9c5f1c10c8ce826037b","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"arsen","range":"(0,050 – 5) mg/l"},{"name":"bar","range":"(0,010 – 5) mg/l"},{"name":"bor","range":"(0,080 – 5) mg/l"},{"name":"glin","range":"(0,050 – 5) mg/l"},{"name":"kadm","range":"(0,005 – 5) mg/l"},{"name":"chrom","range":"(0,003 – 5) mg/l"},{"name":"kobalt","range":"(0,005 – 5) mg/l"},{"name":"miedź","range":"(0,005 – 5) mg/l"},{"name":"żelazo","range":"(0,020 – 5) mg/l"},{"name":"ołów","range":"(0,010 – 5) mg/l"},{"name":"mangan","range":"(0,020 – 5) mg/l"},{"name":"molibden","range":"(0,005 – 5) mg/l"},{"name":"nikiel","range":"(0,005 – 5) mg/l"},{"name":"selen","range":"(0,050 – 5) mg/l"},{"name":"srebro","range":"(0,005 – 5) mg/l"},{"name":"tytan","range":"(0,010 – 5) mg/l"},{"name":"wanad","range":"(0,010 – 5) mg/l"},{"name":"cynk","range":"(0,010 – 5) mg/l"}],"parameters_en":[{"name":"arsenic","range":"(0,050 – 5) mg/l"},{"name":"barium","range":"(0,010 – 5) mg/l"},{"name":"boron","range":"(0,080 – 5) mg/l"},{"name":"aluminium","range":"(0,050 – 5) mg/l"},{"name":"cadmium","range":"(0,005 – 5) mg/l"},{"name":"chromium","range":"(0,003 – 5) mg/l"},{"name":"cobalt","range":"(0,005 – 5) mg/l"},{"name":"copper","range":"(0,005 – 5) mg/l"},{"name":"iron","range":"(0,020 – 5) mg/l"},{"name":"lead","range":"(0,010 – 5) mg/l"},{"name":"manganese","range":"(0,020 – 5) mg/l"},{"name":"molybdenum","range":"(0,005 – 5) mg/l"},{"name":"nickel","range":"(0,005 – 5) mg/l"},{"name":"selenium","range":"(0,050 – 5) mg/l"},{"name":"silver","range":"(0,005 – 5) mg/l"},{"name":"titanium","range":"(0,010 – 5) mg/l"},{"name":"vanadium","range":"(0,010 – 5) mg/l"},{"name":"zinc","range":"(0,010 – 5) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\narsen (0,050 – 5) mg/l\nbar (0,010 – 5) mg/l\nbor (0,080 – 5) mg/l\nglin (0,050 – 5) mg/l\nkadm (0,005 – 5) mg/l\nchrom (0,003 – 5) mg/l\nkobalt (0,005 – 5) mg/l\nmiedź (0,005 – 5) mg/l\nżelazo (0,020 – 5) mg/l\nołów (0,010 – 5) mg/l\nmangan (0,020 – 5) mg/l\nmolibden (0,005 – 5) mg/l\nnikiel (0,005 – 5) mg/l\nselen (0,050 – 5) mg/l\nsrebro (0,005 – 5) mg/l\ntytan (0,010 – 5) mg/l\nwanad (0,010 – 5) mg/l\ncynk (0,010 – 5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\narsen (0,050 – 5) mg/l\nbar (0,010 – 5) mg/l\nbor (0,080 – 5) mg/l\nglin (0,050 – 5) mg/l\nkadm (0,005 – 5) mg/l\nchrom (0,003 – 5) mg/l\nkobalt (0,005 – 5) mg/l\nmiedź (0,005 – 5) mg/l\nżelazo (0,020 – 5) mg/l\nołów (0,010 – 5) mg/l\nmangan (0,020 – 5) mg/l\nmolibden (0,005 – 5) mg/l\nnikiel (0,005 – 5) mg/l\nselen (0,050 – 5) mg/l\nsrebro (0,005 – 5) mg/l\ntytan (0,010 – 5) mg/l\nwanad (0,010 – 5) mg/l\ncynk (0,010 – 5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\narsen (0,050 – 5) mg/l\nbar (0,010 – 5) mg/l\nbor (0,080 – 5) mg/l\nglin (0,050 – 5) mg/l\nkadm (0,005 – 5) mg/l\nchrom (0,003 – 5) mg/l\nkobalt (0,005 – 5) mg/l\nmiedz (0,005 – 5) mg/l\nzelazo (0,020 – 5) mg/l\nolow (0,010 – 5) mg/l\nmangan (0,020 – 5) mg/l\nmolibden (0,005 – 5) mg/l\nnikiel (0,005 – 5) mg/l\nselen (0,050 – 5) mg/l\nsrebro (0,005 – 5) mg/l\ntytan (0,010 – 5) mg/l\nwanad (0,010 – 5) mg/l\ncynk (0,010 – 5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic barium boron aluminium cadmium chromium cobalt copper iron lead manganese molybdenum nickel selenium silver titanium vanadium zinc PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"砷","range":"(0,050 – 5) mg/l"},{"name":"钡","range":"(0,010 – 5) mg/l"},{"name":"硼","range":"(0,080 – 5) mg/l"},{"name":"铝","range":"(0,050 – 5) mg/l"},{"name":"镉","range":"(0,005 – 5) mg/l"},{"name":"铬","range":"(0,003 – 5) mg/l"},{"name":"钴","range":"(0,005 – 5) mg/l"},{"name":"铜","range":"(0,005 – 5) mg/l"},{"name":"铁","range":"(0,020 – 5) mg/l"},{"name":"铅","range":"(0,010 – 5) mg/l"},{"name":"锰","range":"(0,020 – 5) mg/l"},{"name":"钼","range":"(0,005 – 5) mg/l"},{"name":"镍","range":"(0,005 – 5) mg/l"},{"name":"硒","range":"(0,050 – 5) mg/l"},{"name":"银","range":"(0,005 – 5) mg/l"},{"name":"钛","range":"(0,010 – 5) mg/l"},{"name":"钒","range":"(0,010 – 5) mg/l"},{"name":"锌","range":"(0,010 – 5) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 钡 硼 铝 镉 铬 钴 铜 铁 铅 锰 钼 镍 硒 银 钛 钒 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a5dc9c5f1c10c8ce826037c","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10 – 1500) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10 – 1500) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c5f1c10c8ce826037d","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,20 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Scieki Stezenie azotu amonowego\nZakres (0,20 – 10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 10) mg/l"}],"search_zh":"污水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a5dc9c5f1c10c8ce826037e","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie węglowodorów aromatycznych (BTEX)","methodology_en":"Aromatic hydrocarbons (BTEX) concentration","parameters":[{"name":"benzen","range":"(0,250 – 100) mg/kg"},{"name":"toluen","range":"(0,250 – 100) mg/kg"},{"name":"etylobenzen","range":"(0,250 – 100) mg/kg"},{"name":"o-ksylen","range":"(0,250 – 100) mg/kg"},{"name":"(m+p)-ksylen","range":"(0,500 – 200) mg/kg"}],"parameters_en":[{"name":"benzene","range":"(0,250 – 100) mg/kg"},{"name":"toluene","range":"(0,250 – 100) mg/kg"},{"name":"ethylbenzene","range":"(0,250 – 100) mg/kg"},{"name":"o-xylene","range":"(0,250 – 100) mg/kg"},{"name":"(m+p)-xylene","range":"(0,500 – 200) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcja płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcja płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (0,250 – 100) mg/kg\ntoluen (0,250 – 100) mg/kg\netylobenzen (0,250 – 100) mg/kg\no-ksylen (0,250 – 100) mg/kg\n(m+p)-ksylen (0,500 – 200) mg/kg\nMetoda chromatografii gazowej z detekcja płomieniowo-jonizacyjną (GC-FID)","reference":"PB-69/KA wydanie 1 z dnia 26.03.2024","norm_bases":["PB-69/KA wydanie 1 z dnia 26.03.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (0,250 – 100) mg/kg\ntoluen (0,250 – 100) mg/kg\netylobenzen (0,250 – 100) mg/kg\no-ksylen (0,250 – 100) mg/kg\n(m+p)-ksylen (0,500 – 200) mg/kg\nMetoda chromatografii gazowej z detekcja płomieniowo-jonizacyjną (GC-FID) PB-69/KA wydanie 1 z dnia 26.03.2024 Gleba Stezenie weglowodorow aromatycznych (BTEX)\nZakres:\nbenzen (0,250 – 100) mg/kg\ntoluen (0,250 – 100) mg/kg\netylobenzen (0,250 – 100) mg/kg\no-ksylen (0,250 – 100) mg/kg\n(m+p)-ksylen (0,500 – 200) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-69/KA wydanie 1 z dnia 26.03.2024","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Aromatic hydrocarbons (BTEX) concentration Gas chromatography with flame ionization detection (GC-FID) benzene toluene ethylbenzene o-xylene (m+p)-xylene PB-69/KA wydanie 1 z dnia 26.03.2024","search_zh":"土壤 芳香烃（BTEX）浓度 苯 甲苯 乙苯 邻二甲苯 (间+对)-二甲苯 PB-69/KA wydanie 1 z dnia 26.03.2024","test_object_zh":"土壤","parameters_zh":[{"name":"苯","range":"(0,250 – 100) mg/kg"},{"name":"甲苯","range":"(0,250 – 100) mg/kg"},{"name":"乙苯","range":"(0,250 – 100) mg/kg"},{"name":"邻二甲苯","range":"(0,250 – 100) mg/kg"},{"name":"(间+对)-二甲苯","range":"(0,500 – 200) mg/kg"}],"methodology_zh":"芳香烃（BTEX）浓度"},{"_id":"6a5dc9c5f1c10c8ce826037f","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Suma węglowodorów C6-C12 (zawartość benzyn)","methodology_en":"Sum of hydrocarbons C6-C12 (gasoline content)","parameters":[{"name":"Zakres","range":"(1 – 500) mg/kg"}],"parameters_en":[{"name":"Range","range":"(1 – 500) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Suma węglowodorów C6-C12 (zawartość benzyn)\nZakres (1 – 500) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-91/KA wydanie 1 z dnia 26.03.2024","norm_bases":["PB-91/KA wydanie 1 z dnia 26.03.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Suma węglowodorów C6-C12 (zawartość benzyn)\nZakres (1 – 500) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-91/KA wydanie 1 z dnia 26.03.2024 Gleba Suma weglowodorow C6-C12 (zawartosc benzyn)\nZakres (1 – 500) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-91/KA wydanie 1 z dnia 26.03.2024","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sum of hydrocarbons C6-C12 (gasoline content) Gas chromatography with flame ionization detection (GC-FID) Range PB-91/KA wydanie 1 z dnia 26.03.2024","parameters_zh":[{"name":"范围","range":"(1 – 500) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-91/KA wydanie 1 z dnia 26.03.2024","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a5dc9c5f1c10c8ce8260380","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Suma węglowodorów C12-C35 (zawartość oleju mineralnego)","methodology_en":"Sum of hydrocarbons C12-C35 (mineral oil content)","parameters":[{"name":"Zakres","range":"(40-10000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(40-10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Suma węglowodorów C12-C35 (zawartość oleju mineralnego)\nZakres (40-10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-91/KA wydanie 1 z dnia 26.03.2024","norm_bases":["PB-91/KA wydanie 1 z dnia 26.03.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Suma węglowodorów C12-C35 (zawartość oleju mineralnego)\nZakres (40-10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-91/KA wydanie 1 z dnia 26.03.2024 Gleba Suma weglowodorow C12-C35 (zawartosc oleju mineralnego)\nZakres (40-10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-91/KA wydanie 1 z dnia 26.03.2024","categories":["environment","petro"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sum of hydrocarbons C12-C35 (mineral oil content) Gas chromatography with flame ionization detection (GC-FID) Range PB-91/KA wydanie 1 z dnia 26.03.2024","parameters_zh":[{"name":"范围","range":"(40-10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-91/KA wydanie 1 z dnia 26.03.2024","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a5dc9c5f1c10c8ce8260381","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"25 μS/cm – 10 mS/cm"}],"parameters_en":[{"name":"Range","range":"25 μS/cm – 10 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres 25 μS/cm – 10 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres 25 μS/cm – 10 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres 25 μS/cm – 10 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"25 μS/cm – 10 mS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260382","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260383","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 4000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 4000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 4000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 4000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260384","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(100 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(100 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (100 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (100 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Calkowite substancje rozpuszczone (TDS)\nZakres (100 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(100 – 5000) mg/l"}],"search_zh":"水、污水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a5dc9c5f1c10c8ce8260385","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(20 – 2000) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(20 – 2000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20 – 2000) mg/l O2\nMetoda miareczkowa","reference":"PB-7/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-7/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20 – 2000) mg/l O2\nMetoda miareczkowa PB-7/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20 – 2000) mg/l O2\nMetoda miareczkowa PB-7/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method COD-Cr Range PB-7/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(20 – 2000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 化学需氧量（COD-Cr） 范围 PB-7/KA wydanie 2 z dnia 25.04.2025","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c5f1c10c8ce8260386","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(6 – 1000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(6 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(6 – 1000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260387","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce8260388","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(1,0 – 700) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 700) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 700) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 700) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,0 – 700) mg/l\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration (TOC) Spectrometry method in the infrared range (IR) Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(1,0 – 700) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"红外光谱法（IR）"},{"_id":"6a5dc9c5f1c10c8ce8260389","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 300) mg/l"}],"technique":"Metoda analizy przepływowej (FIA) z detekcją spektrofotometryczną","techniques":["Metoda analizy przepływowej (FIA) z detekcją spektrofotometryczną"],"technique_en":"Flow analysis (FIA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 300) mg/l\nMetoda analizy przepływowej (FIA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,010 – 300) mg/l\nMetoda analizy przepływowej (FIA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,010 – 300) mg/l\nMetoda analizy przeplywowej (FIA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Flow analysis (FIA) with spectrophotometric detection Range PN-EN ISO 13395:2001","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 300) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 范围 PN-EN ISO 13395:2001","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826038a","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,03 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,03 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,03 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,03 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 100) mg/l"}],"search_zh":"水、污水 总磷浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826038b","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,70 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,70 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,70 – 250) mg/l\nMetoda miareczkowa","reference":"PB-4/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-4/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,70 – 250) mg/l\nMetoda miareczkowa PB-4/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,70 – 250) mg/l\nMetoda miareczkowa PB-4/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PB-4/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,70 – 250) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PB-4/KA wydanie 2 z dnia 25.04.2025","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826038c","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-5/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-5/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-5/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-5/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-5/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-5/KA wydanie 2 z dnia 25.04.2025","test_object_zh":"水、污水"},{"_id":"6a5dc9c5f1c10c8ce826038d","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,050 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 Metoda B","norm_bases":["PN-ISO 6439:1994 Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Metoda B Woda, Scieki Indeks fenolowy\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Metoda B","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994 Metoda B","parameters_zh":[{"name":"范围","range":"(0,050 – 50) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PN-ISO 6439:1994 Metoda B","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a5dc9c5f1c10c8ce826038e","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie cyjanków wolnych","methodology_en":"Free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603/01","norm_bases":["PN-80/C-04603/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie cyjanków wolnych\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 Woda, Scieki Stezenie cyjankow wolnych\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Free cyanide concentration Spectrophotometric method Range PN-80/C-04603/01","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、污水 游离氰化物浓度 分光光度法 范围 PN-80/C-04603/01","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"游离氰化物浓度"},{"_id":"6a5dc9c5f1c10c8ce826038f","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(20 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (20 – 200) mg/l\nMetoda wagowa","reference":"PB-6/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-6/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (20 – 200) mg/l\nMetoda wagowa PB-6/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (20 – 200) mg/l\nMetoda wagowa PB-6/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-6/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"范围","range":"(20 – 200) mg/l"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 范围 PB-6/KA wydanie 2 z dnia 25.04.2025","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9c5f1c10c8ce8260390","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pierwiastków:","methodology_en":"Element concentrations:","parameters":[{"name":"cynk","range":"(0,010 – 10) mg/l"},{"name":"miedź","range":"(0,010 – 10) mg/l"},{"name":"kadm","range":"(0,010 – 10) mg/l"},{"name":"nikiel","range":"(0,010 – 10) mg/l"},{"name":"ołów","range":"(0,010 – 10) mg/l"},{"name":"mangan","range":"(0,010 – 10) mg/l"},{"name":"żelazo","range":"(0,010 – 10) mg/l"},{"name":"chrom","range":"(0,010 – 10) mg/l"}],"parameters_en":[{"name":"zinc","range":"(0,010 – 10) mg/l"},{"name":"copper","range":"(0,010 – 10) mg/l"},{"name":"cadmium","range":"(0,010 – 10) mg/l"},{"name":"nickel","range":"(0,010 – 10) mg/l"},{"name":"lead","range":"(0,010 – 10) mg/l"},{"name":"manganese","range":"(0,010 – 10) mg/l"},{"name":"iron","range":"(0,010 – 10) mg/l"},{"name":"chromium","range":"(0,010 – 10) mg/l"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków:\nZakres:\ncynk (0,010 – 10) mg/l\nmiedź (0,010 – 10) mg/l\nkadm (0,010 – 10) mg/l\nnikiel (0,010 – 10) mg/l\nołów (0,010 – 10) mg/l\nmangan (0,010 – 10) mg/l\nżelazo (0,010 – 10) mg/l\nchrom (0,010 – 10) mg/l\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-18/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-18/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pierwiastków:\nZakres:\ncynk (0,010 – 10) mg/l\nmiedź (0,010 – 10) mg/l\nkadm (0,010 – 10) mg/l\nnikiel (0,010 – 10) mg/l\nołów (0,010 – 10) mg/l\nmangan (0,010 – 10) mg/l\nżelazo (0,010 – 10) mg/l\nchrom (0,010 – 10) mg/l\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-18/KA wydanie 2 z dnia 25.04.2025 Woda, Scieki Stezenie pierwiastkow:\nZakres:\ncynk (0,010 – 10) mg/l\nmiedz (0,010 – 10) mg/l\nkadm (0,010 – 10) mg/l\nnikiel (0,010 – 10) mg/l\nolow (0,010 – 10) mg/l\nmangan (0,010 – 10) mg/l\nzelazo (0,010 – 10) mg/l\nchrom (0,010 – 10) mg/l\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-18/KA wydanie 2 z dnia 25.04.2025","categories":["water","materials"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Element concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) zinc copper cadmium nickel lead manganese iron chromium PB-18/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"元素浓度：","parameters_zh":[{"name":"锌","range":"(0,010 – 10) mg/l"},{"name":"铜","range":"(0,010 – 10) mg/l"},{"name":"镉","range":"(0,010 – 10) mg/l"},{"name":"镍","range":"(0,010 – 10) mg/l"},{"name":"铅","range":"(0,010 – 10) mg/l"},{"name":"锰","range":"(0,010 – 10) mg/l"},{"name":"铁","range":"(0,010 – 10) mg/l"},{"name":"铬","range":"(0,010 – 10) mg/l"}],"search_zh":"水、污水 元素浓度： 电感耦合等离子体发射光谱法（ICP-OES） 锌 铜 镉 镍 铅 锰 铁 铬 PB-18/KA wydanie 2 z dnia 25.04.2025","test_object_zh":"水、污水","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a5dc9c5f1c10c8ce8260391","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie anionów:","methodology_en":"Anion concentrations:","parameters":[{"name":"fluorki","range":"(0,3 – 1000) mg/l"},{"name":"chlorki","range":"(1 – 1000) mg/l"},{"name":"azot azotanowy","range":"(0,3 – 1000) mg/l"},{"name":"siarczany","range":"(2 – 1000) mg/l"}],"parameters_en":[{"name":"fluorides","range":"(0,3 – 1000) mg/l"},{"name":"chlorides","range":"(1 – 1000) mg/l"},{"name":"nitrate nitrogen","range":"(0,3 – 1000) mg/l"},{"name":"sulfates","range":"(2 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów:\nZakres:\nfluorki (0,3 – 1000) mg/l\nchlorki (1 – 1000) mg/l\nazot azotanowy (0,3 – 1000) mg/l\nsiarczany (2 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie anionów:\nZakres:\nfluorki (0,3 – 1000) mg/l\nchlorki (1 – 1000) mg/l\nazot azotanowy (0,3 – 1000) mg/l\nsiarczany (2 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow:\nZakres:\nfluorki (0,3 – 1000) mg/l\nchlorki (1 – 1000) mg/l\nazot azotanowy (0,3 – 1000) mg/l\nsiarczany (2 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) fluorides chlorides nitrate nitrogen sulfates PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度：","search_zh":"水、污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硝酸盐氮 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"氟化物","range":"(0,3 – 1000) mg/l"},{"name":"氯化物","range":"(1 – 1000) mg/l"},{"name":"硝酸盐氮","range":"(0,3 – 1000) mg/l"},{"name":"硫酸盐","range":"(2 – 1000) mg/l"}]},{"_id":"6a5dc9c5f1c10c8ce8260392","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,001 – 0,1) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,1) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,001 – 0,1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-19/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PB-19/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci\nZakres (0,001 – 0,1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-19/KA wydanie 2 z dnia 25.04.2025 Scieki Stezenie rteci\nZakres (0,001 – 0,1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-19/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-19/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 0,1) mg/l"}],"search_zh":"污水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-19/KA wydanie 2 z dnia 25.04.2025","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"污水"},{"_id":"6a5dc9c5f1c10c8ce8260393","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Sucha masa/zawartość wody","methodology_en":"Dry matter/water content","parameters":[{"name":"Zakres","range":"(5,0 – 95) %"}],"parameters_en":[{"name":"Range","range":"(5,0 – 95) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha masa/zawartość wody\nZakres (5,0 – 95) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Sucha masa/zawartość wody\nZakres (5,0 – 95) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Sucha masa/zawartosc wody\nZakres (5,0 – 95) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Dry matter/water content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(5,0 – 95) %"}],"search_zh":"土壤 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a5dc9c5f1c10c8ce8260394","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH Potentiometric method Range PN-EN ISO 10390:2022-09","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"土壤 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a5dc9c5f1c10c8ce8260395","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe","test_object_en":"Surface waters","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","methodology_en":"Sampling for chemical, physical testing","parameters":[{"name":"Temperatura pobranej próbki wody"},{"name":"Zakres","range":"(1,0 – 25,0) °C"}],"parameters_en":[{"name":"Temperature of the collected water sample"},{"name":"Range","range":"(1,0 – 25,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (1,0 – 25,0) °C\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 | PB-17/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PN-EN ISO 5667-6:2016-12","PB-17/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe Pobieranie próbek do badań chemicznych, fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (1,0 – 25,0) °C\nMetoda manualna PN-EN ISO 5667-6:2016-12 | PB-17/KA wydanie 2 z dnia 25.04.2025 Wody powierzchniowe Pobieranie probek do badan chemicznych, fizycznych\nZakres:\nTemperatura pobranej probki wody\nZakres (1,0 – 25,0) °C\nMetoda manualna PN-EN ISO 5667-6:2016-12 | PB-17/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters Sampling for chemical, physical testing Manual method Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 | PB-17/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"所采水样的温度"},{"name":"范围","range":"(1,0 – 25,0) °C"}],"search_zh":"地表水 用于化学、物理检验的采样 手工法 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 | PB-17/KA wydanie 2 z dnia 25.04.2025","technique_zh":"手工法","test_object_zh":"地表水","methodology_zh":"用于化学、物理检验的采样"},{"_id":"6a5dc9c5f1c10c8ce8260396","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe","test_object_en":"Surface waters","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Wody powierzchniowe Stezenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l O2"}],"search_zh":"地表水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","methodology_zh":"溶解氧浓度","test_object_zh":"地表水"},{"_id":"6a5dc9c5f1c10c8ce8260397","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe","test_object_en":"Surface waters","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Wody powierzchniowe pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"地表水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"地表水"},{"_id":"6a5dc9c5f1c10c8ce8260398","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe","test_object_en":"Surface waters","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 – 10 000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 – 10 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe Przewodność elektryczna właściwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Wody powierzchniowe Przewodnosc elektryczna wlasciwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 10 000) μS/cm"}],"search_zh":"地表水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"地表水"},{"_id":"6a5dc9c5f1c10c8ce8260399","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe (zbiorniki zaporowe)","test_object_en":"Surface waters (dam reservoirs)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) °C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 25,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 25,0) °C","reference":"PN-ISO 5667-4:2017-10 | PB-17/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PN-ISO 5667-4:2017-10","PB-17/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe (zbiorniki zaporowe) Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 25,0) °C PN-ISO 5667-4:2017-10 | PB-17/KA wydanie 2 z dnia 25.04.2025 Wody powierzchniowe (zbiorniki zaporowe) Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 – 25,0) °C PN-ISO 5667-4:2017-10 | PB-17/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters (dam reservoirs) Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-4:2017-10 | PB-17/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) °C"}],"search_zh":"地表水（拦河水库） 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-4:2017-10 | PB-17/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地表水（拦河水库）"},{"_id":"6a5dc9c5f1c10c8ce826039a","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe (zbiorniki zaporowe)","test_object_en":"Surface waters (dam reservoirs)","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe (zbiorniki zaporowe) pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Wody powierzchniowe (zbiorniki zaporowe) pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters (dam reservoirs) pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"地表水（拦河水库） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"地表水（拦河水库）"},{"_id":"6a5dc9c5f1c10c8ce826039b","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Wody powierzchniowe (zbiorniki zaporowe)","test_object_en":"Surface waters (dam reservoirs)","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 - 10 000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 - 10 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 - 10 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody powierzchniowe (zbiorniki zaporowe) Przewodność elektryczna właściwa\nZakres (100 - 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Wody powierzchniowe (zbiorniki zaporowe) Przewodnosc elektryczna wlasciwa\nZakres (100 - 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface waters (dam reservoirs) Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 - 10 000) μS/cm"}],"search_zh":"地表水（拦河水库） 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"地表水（拦河水库）"},{"_id":"6a5dc9c5f1c10c8ce826039c","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Pomiar temperatury próbki wody","methodology_en":"Sampling for chemical and physical testing Measurement of the temperature of the water sample","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) oC"}],"parameters_en":[{"name":"Range","range":"(1,0 – 25,0) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Pomiar temperatury próbki wody\nZakres (1,0 – 25,0) oC","reference":"PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3 | PB-17/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3","PB-17/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Pomiar temperatury próbki wody\nZakres (1,0 – 25,0) oC PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3 | PB-17/KA wydanie 2 z dnia 25.04.2025 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Pomiar temperatury probki wody\nZakres (1,0 – 25,0) oC PN-ISO 5667-11:2017-10 z wyl. pkt. 5.2, 6.2, 6.3 | PB-17/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Sampling for chemical and physical testing Measurement of the temperature of the water sample Range PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3 | PB-17/KA wydanie 2 z dnia 25.04.2025","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) oC"}],"search_zh":"地下水 范围 PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3 | PB-17/KA wydanie 2 z dnia 25.04.2025","test_object_zh":"地下水"},{"_id":"6a5dc9c5f1c10c8ce826039d","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda podziemna Stezenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l O2"}],"search_zh":"地下水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","methodology_zh":"溶解氧浓度","test_object_zh":"地下水"},{"_id":"6a5dc9c5f1c10c8ce826039e","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda podziemna pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"地下水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"地下水"},{"_id":"6a5dc9c5f1c10c8ce826039f","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 – 10 000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 – 10 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Przewodność elektryczna właściwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda podziemna Przewodnosc elektryczna wlasciwa\nZakres (100 – 10 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 10 000) μS/cm"}],"search_zh":"地下水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"地下水"},{"_id":"6a5dc9c5f1c10c8ce82603a0","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 25,0) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 25,0) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 25,0) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PB-17/KA wydanie 2 z dnia 25.04.2025","norm_bases":["PN-ISO 5667-10:2021-11","PB-17/KA wydanie 2 z dnia 25.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 25,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PB-17/KA wydanie 2 z dnia 25.04.2025 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (1,0 – 25,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PB-17/KA wydanie 2 z dnia 25.04.2025","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PB-17/KA wydanie 2 z dnia 25.04.2025","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(1,0 – 25,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PB-17/KA wydanie 2 z dnia 25.04.2025","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9c5f1c10c8ce82603a1","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9c5f1c10c8ce82603a2","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Gleby","test_object_en":"Soils","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","methodology_en":"Sampling for physical and chemical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleby Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleby Pobieranie probek do badan fizycznych i chemicznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soils Sampling for physical and chemical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","methodology_zh":"物理与化学检测用样品采集","search_zh":"土壤 物理与化学检测用样品采集 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5dc9c5f1c10c8ce82603a3","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","methodology_en":"Sampling for physical and chemical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań fizycznych i chemicznych PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7 Osady sciekowe Pobieranie probek do badan fizycznych i chemicznych PN-EN ISO 5667-13:2011 z wylaczeniem punktow 6.3.3; 6.3.4; 6.3.5; 6.3.7","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sampling for physical and chemical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7","methodology_zh":"物理与化学检测用样品采集","search_zh":"污泥 物理与化学检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7","test_object_zh":"污泥"},{"_id":"6a5dc9c5f1c10c8ce82603a4","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Odpady","test_object_en":"Waste","methodology":"Badania interwencyjne (wg Programu DAB-11)","methodology_en":"Intervention testing (according to Programme DAB-11)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania interwencyjne (wg Programu DAB-11)","reference":"PB-11/CLB wydanie 1 z dnia 25.09.2023","norm_bases":["PB-11/CLB wydanie 1 z dnia 25.09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023","search_zh":"废物 干预性检验（依据 DAB-11 计划） PB-11/CLB wydanie 1 z dnia 25.09.2023","test_object_zh":"废物","methodology_zh":"干预性检验（依据 DAB-11 计划）"},{"_id":"6a5dc9c5f1c10c8ce82603a5","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment - noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H","norm_bases":["Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wylaczeniem pkt. H","categories":["environment"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5dc9c5f1c10c8ce82603a6","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment - noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H","norm_bases":["Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wylaczeniem pkt. H","categories":["environment"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (tj. Dz.U. z 2011 r., nr 140, poz. 824 i nr 288, poz. 1697) z wyłączeniem pkt. H","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5dc9c5f1c10c8ce82603a7","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wylaczeniem punku F","categories":["environment"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9c5f1c10c8ce82603a8","lab_id":"69ad52a3de79e566650fb161","country":"PL","accr_number":"AB 188","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wylaczeniem punku F","categories":["environment"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punku F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"}],"has_pdf":true}