🇵🇱 BIALSKIE WODOCIĄGI I KANALIZACJA "WOD-KAN" Sp. z o.o. PL
Water & wastewaterMicrobiology
BIALSKIE WODOCIĄGI I KANALIZACJA "WOD-KAN" Sp. z o.o. is a laboratory accredited by PCA under number AB 1812 (Biała Podlaska, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 1812
- Methods in scope: 36
- Types of test objects: 4
- Techniques used: 11
- City: Biała Podlaska, Poland
- Accreditation number
- AB 1812
- Accreditation body
- PCA
- Address
- ul. Narutowicza 35 A, 21-500 Biała Podlaska
- City
- Biała Podlaska, Poland
What this laboratory tests (4)
- Water intended for human consumption — 18 methods
- Water, wastewater — 15 methods
- Wastewater — 2 methods
- Water — 1 method
Analytical techniques used (11)
- Spectrophotometric method — 12 methods
- Titrimetric method — 4 methods
- Membrane filtration method — 3 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Automatic method; Manual method — 1 method
- Conductometric method — 1 method
- Nephelometric method — 1 method
Accreditation scope — test methods (36)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range (5,0 – 20,0) °C |
PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584 | ||
| 2 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6 | ||
| 3 | Water intended for human consumption | Manganese concentration Range (15 – 500) μg/l |
Spectrophotometric method | PN-92/C-04590.03 | |
| 4 | Water intended for human consumption | Iron concentration Range (40 – 2000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 5 | Water intended for human consumption | Ammonium ion concentration Range (0,13 – 1,61) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 6 | Water intended for human consumption | Nitrite concentration Range (0,016 – 1,65) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 7 | Water intended for human consumption | Nitrate concentration Range (0,44 – 50,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 8 | Water intended for human consumption | pH Range 2,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 9 | Water intended for human consumption | Electrical conductivity Range (100 − 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 10 | Water intended for human consumption | Turbidity Range (0,10 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 11 | Water intended for human consumption | Colour Range (5 – 40) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C | |
| 12 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 13 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 14 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 15 | Water intended for human consumption | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 16 | Water intended for human consumption | Total microorganism count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 17 | Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 18 | Water intended for human consumption | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 19 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (5,0 – 30,0) °C |
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6 | PN-77/C-04584 | ||
| 20 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (5,0 – 40,0) °C |
Automatic method; Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 21 | Wastewater | Ammonium nitrogen concentration Range (2,00 – 200) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 22 | Water, wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 23 | Water, wastewater | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 24 | Water, wastewater | Dissolved oxygen concentration Range (0,5 – 14,0) mg/l O2 |
Electrochemical method | PN-EN ISO 5814-1:2013-04 | |
| 25 | Water, wastewater | Biochemical oxygen demand − BOD5 Range (1,0 – 6000) mg/l O2 |
Electrochemical method | P N-EN ISO 5815-1:2019-12 | |
| 26 | Water, wastewater | Chemical oxygen demand − COD-Cr Range (10,0 – 5000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 27 | Water, wastewater | Nitrite nitrogen concentration Range (0,0125 – 10,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 28 | Water, wastewater | Ammonium nitrogen concentration Range (0,10 – 100) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 29 | Water, wastewater | Nitrate nitrogen concentration Range (0,20 – 50) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 30 | Water, wastewater | Kjeldahl nitrogen concentration Range (2,00 – 200) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 31 | Water, wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576.14 | ||
| 32 | Water, wastewater | Chloride concentration Range (5,0 – 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 33 | Water, wastewater | Sulfate concentration Range (10,0 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 34 | Water, wastewater | Total phosphorus concentration Range (0,10 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010 | |
| 35 | Water, wastewater | Total alkalinity Range (0,4 – 20) mmol/l Range (20 – 1000) mg/l CaCO3 |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 36 | Water, wastewater | Total nitrogen concentration Range (1,00 – 150) mg/l |
Spectrophotometric method | PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138 | |
Reference standards (30)
P N-EN ISO 5815-1:2019-12
PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6
PN-EN ISO 5814-1:2013-04
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994