🇵🇱 BIALSKIE WODOCIĄGI I KANALIZACJA "WOD-KAN" Sp. z o.o. PL

PCA AB 1812 • Biała Podlaska, Poland • 36 methods

Water & wastewaterMicrobiology

BIALSKIE WODOCIĄGI I KANALIZACJA "WOD-KAN" Sp. z o.o. is a laboratory accredited by PCA under number AB 1812 (Biała Podlaska, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 1812
  • Methods in scope: 36
  • Types of test objects: 4
  • Techniques used: 11
  • City: Biała Podlaska, Poland
Accreditation number
AB 1812
Accreditation body
PCA
Address
ul. Narutowicza 35 A, 21-500 Biała Podlaska
City
Biała Podlaska, Poland

What this laboratory tests (4)

Analytical techniques used (11)

Accreditation scope — test methods (36)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken
Range (5,0 – 20,0) °C
PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584
2 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
3 Water intended for human consumption Manganese concentration
Range (15 – 500) μg/l
Spectrophotometric method PN-92/C-04590.03
4 Water intended for human consumption Iron concentration
Range (40 – 2000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
5 Water intended for human consumption Ammonium ion concentration
Range (0,13 – 1,61) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
6 Water intended for human consumption Nitrite concentration
Range (0,016 – 1,65) mg/l
Spectrophotometric method PN-EN 26777:1999
7 Water intended for human consumption Nitrate concentration
Range (0,44 – 50,0) mg/l
Spectrophotometric method PN-82/C-04576.08
8 Water intended for human consumption pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
9 Water intended for human consumption Electrical conductivity
Range (100 − 5000) μS/cm
Conductometric method PN-EN 27888:1999
10 Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
11 Water intended for human consumption Colour
Range (5 – 40) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C
12 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
13 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
14 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
15 Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
16 Water intended for human consumption Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
17 Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
18 Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
19 Water Sampling for chemical and physical testing Temperature of the water sample taken
Range (5,0 – 30,0) °C
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6 | PN-77/C-04584
20 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (5,0 – 40,0) °C
Automatic method; Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
21 Wastewater Ammonium nitrogen concentration
Range (2,00 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
22 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
23 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
24 Water, wastewater Dissolved oxygen concentration
Range (0,5 – 14,0) mg/l O2
Electrochemical method PN-EN ISO 5814-1:2013-04
25 Water, wastewater Biochemical oxygen demand − BOD5
Range (1,0 – 6000) mg/l O2
Electrochemical method P N-EN ISO 5815-1:2019-12
26 Water, wastewater Chemical oxygen demand − COD-Cr
Range (10,0 – 5000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
27 Water, wastewater Nitrite nitrogen concentration
Range (0,0125 – 10,0) mg/l
Spectrophotometric method PN-EN 26777:1999
28 Water, wastewater Ammonium nitrogen concentration
Range (0,10 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
29 Water, wastewater Nitrate nitrogen concentration
Range (0,20 – 50) mg/l
Spectrophotometric method PN-82/C-04576.08
30 Water, wastewater Kjeldahl nitrogen concentration
Range (2,00 – 200) mg/l
Titrimetric method PN-EN 25663:2001
31 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14
32 Water, wastewater Chloride concentration
Range (5,0 – 5000) mg/l
Titrimetric method PN-ISO 9297:1994
33 Water, wastewater Sulfate concentration
Range (10,0 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
34 Water, wastewater Total phosphorus concentration
Range (0,10 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
35 Water, wastewater Total alkalinity
Range (0,4 – 20) mmol/l Range (20 – 1000) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
36 Water, wastewater Total nitrogen concentration
Range (1,00 – 150) mg/l
Spectrophotometric method PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138

Reference standards (30)

P N-EN ISO 5815-1:2019-12
PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6
PN-EN ISO 5814-1:2013-04
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994