{"lab":{"_id":"69ad52a3de79e566650fb9b1","accr_number":"AB 1812","country":"PL","accr_body":"PCA","address":"ul. Narutowicza 35 A, 21-500 Biała Podlaska","categories":["water","microbiology"],"city":"Biała Podlaska","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"BIALSKIE WODOCIĄGI I KANALIZACJA \"WOD-KAN\" Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1812.pdf"],"scope_summary":"","search_text":"bialskie wodociągi i kanalizacja \"wod-kan\" sp. z o.o. ul. narutowicza 35 a, 21-500 biała podlaska water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:56.878Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:56.878Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201812,podmiot.html","fields_of_testing":[{"codes":"C/28P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and samling of drinking water"}],"issue":{"no":"5","date":"03.12.2025"},"parse_date":"2026-07-20T07:09:30.026Z","parse_source":"script-pdfplumber","map_coord":[52.031648,23.120067],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":36,"microbiology":5},"category_scores":{"water":31.61,"microbiology":0.61},"has_zh":true},"methods":[{"_id":"6a5dc9aaf1c10c8ce825a0c1","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(5,0 – 20,0) °C"}],"parameters_en":[{"name":"Range","range":"(5,0 – 20,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (5,0 – 20,0) °C","reference":"PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (5,0 – 20,0) °C PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (5,0 – 20,0) °C PN-ISO 5667-5:2017-10 z wylaczeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(5,0 – 20,0) °C"}],"search_zh":"生活饮用水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-5:2017-10 z wyłączeniem punktu: 10.3; 10.4; 11 | PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9aaf1c10c8ce825a0c2","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt: 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c3","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 – 500) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 – 500) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 – 500) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 500) μg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 500) μg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590.03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 500) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c4","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(40 – 2000) μg/l"}],"parameters_en":[{"name":"Range","range":"(40 – 2000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (40 – 2000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (40 – 2000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (40 – 2000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(40 – 2000) μg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c5","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,13 – 1,61) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,13 – 1,61) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,13 – 1,61) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,13 – 1,61) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,13 – 1,61) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,13 – 1,61) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c6","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,016 – 1,65) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,016 – 1,65) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,016 – 1,65) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,016 – 1,65) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,016 – 1,65) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 1,65) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c7","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,44 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,44 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,44 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,44 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,44 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 50,0) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c8","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0c9","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 − 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 − 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 − 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 − 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 − 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 − 5000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0ca","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0cb","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 40) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (5 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 40) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0cc","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0cd","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0ce","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0cf","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a5dc9aaf1c10c8ce825a0d0","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C","methodology_en":"Total microorganism count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a5dc9aaf1c10c8ce825a0d1","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a0d2","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii Escherichia coli","methodology_en":"Most probable number of Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","search_zh":"生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a5dc9aaf1c10c8ce825a0d3","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(5,0 – 30,0) °C"}],"parameters_en":[{"name":"Range","range":"(5,0 – 30,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (5,0 – 30,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (5,0 – 30,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (5,0 – 30,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem punktu 7.5 i 7.6 | PN-77/C-04584","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(5,0 – 30,0) °C"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.5 i 7.6 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9aaf1c10c8ce825a0d4","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(5,0 – 40,0) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(5,0 – 40,0) °C"}],"technique":"Metoda automatyczna; Metoda manualna","techniques":["Metoda automatyczna","Metoda manualna"],"technique_en":"Automatic method; Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (5,0 – 40,0) °C\nMetoda automatyczna; Metoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (5,0 – 40,0) °C\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (5,0 – 40,0) °C\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method; Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(5,0 – 40,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 自动法；手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"自动法；手工法"},{"_id":"6a5dc9aaf1c10c8ce825a0d5","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,00 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,00 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 200) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9aaf1c10c8ce825a0d6","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0d7","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0d8","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 14,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 14,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814-1:2013-04","norm_bases":["PN-EN ISO 5814-1:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814-1:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814-1:2013-04","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814-1:2013-04","parameters_zh":[{"name":"范围","range":"(0,5 – 14,0) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814-1:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9aaf1c10c8ce825a0d9","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","methodology_en":"Biochemical oxygen demand − BOD5","parameters":[{"name":"Zakres","range":"(1,0 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"P N-EN ISO 5815-1:2019-12","norm_bases":["P N-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna P N-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna P N-EN ISO 5815-1:2019-12","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range P N-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1,0 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 P N-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9aaf1c10c8ce825a0da","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand − COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l O2"}],"search_zh":"水、废水 化学需氧量 － COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9aaf1c10c8ce825a0db","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,0125 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0125 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0125 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0125 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0125 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0125 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0dc","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0dd","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,20 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,20 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0de","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,00 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,00 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 200) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0df","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0e0","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0e1","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10,0 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10,0 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 1000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0e2","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9aaf1c10c8ce825a0e3","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,4 – 20) mmol/l"},{"name":"Zakres","range":"(20 – 1000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,4 – 20) mmol/l"},{"name":"Range","range":"(20 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,4 – 20) mmol/l\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres:\nZakres (0,4 – 20) mmol/l\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres:\nZakres (0,4 – 20) mmol/l\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,4 – 20) mmol/l"},{"name":"范围","range":"(20 – 1000) mg/l CaCO3"}],"search_zh":"水、废水 总碱度 滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a5dc9aaf1c10c8ce825a0e4","lab_id":"69ad52a3de79e566650fb9b1","country":"PL","accr_number":"AB 1812","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,00 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138","norm_bases":["PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (1,00 – 150) mg/l\nMetoda spektrofotometryczna PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138 Woda, scieki Stezenie azotu ogolnego\nZakres (1,00 – 150) mg/l\nMetoda spektrofotometryczna PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 150) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 PB-PF-03 wydanie 2 z dnia 01.10.2025 r. na podstawie testu Hach Lange Nr LCK 138","technique_zh":"分光光度法","test_object_zh":"水、废水"}],"has_pdf":true}