🇵🇱 EKO-CONNECT Sp. z o.o. PL
EnvironmentElectronics & EMC
EKO-CONNECT Sp. z o.o. is a laboratory accredited by PCA under number AB 1810 (Poznań, Poland). Its accreditation scope covers 7 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment – electromagnetic field in the workspace duri…, Environment – electromagnetic field in the vicinity of radiocommuni…, Environment – electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Direct measurement method, (calculated).
At a glance
- Accreditation number: PCA AB 1810
- Methods in scope: 7
- Types of test objects: 3
- Techniques used: 2
- City: Poznań, Poland
- Accreditation number
- AB 1810
- Accreditation body
- PCA
- Address
- ul. Miodowa 14A, 60-591 Poznań
- City
- Poznań, Poland
What this laboratory tests (3)
- Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 2 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) — 2 methods
Analytical techniques used (2)
- Direct measurement method — 4 methods
- (calculated) — 3 methods
Accreditation scope — test methods (7)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań | |||||
| 1 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) | Electric field strength: in the frequency range od 80 MHz do 90 GHz Range (0,8 – 240) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 2 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range od 27 MHz do 1 GHz Range (0,01 – 1,5) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 3 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range od 800 MHz do 90 GHz Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331). |
(calculated) | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 4 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range od 80 MHz do 90 GHz Range (0,8 – 200) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 5 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range od 80 MHz do 90 GHz Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
(calculated) | Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 6 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Electric field strength: in the frequency range od 420 MHz do 6 GHz Range (0,1 – 200) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 7 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Magnetic field strength: in the frequency range od 420 MHz do 6 GHz Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
(calculated) | Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
Reference standards (3)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)