{"lab":{"_id":"69ad52a3de79e566650fb9af","accr_number":"AB 1810","country":"PL","accr_body":"PCA","address":"ul. Miodowa 14A, 60-591 Poznań","categories":["environment"],"city":"Poznań","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"EKO-CONNECT Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1810.pdf"],"scope_summary":"","search_text":"eko-connect sp. z o.o. ul. miodowa 14a, 60-591 poznań environment metrology pharma electronics other","status":"active","updated_at":"2026-03-08T14:50:56.749Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:12:28.656Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201810,podmiot.html","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) - środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"8","date":"29.05.2026"},"parse_date":"2026-08-17T15:12:28.656Z","parse_source":"agent-claude-code","map_coord":[52.413312,16.875373],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/d32451c636ebae5d105c9ef7d182c5f2/AB%201810.pdf","has_en":true,"category_counts":{"environment":7},"category_scores":{"environment":7},"has_zh":true},"methods":[{"_id":"6a8324dc884ede9a1b2c4f94","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 80 MHz do 90 GHz"},{"name":"Zakres","range":"(0,8 – 240) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,8 – 240) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,8 – 240) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (0,8 – 240) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 80 MHz do 90 GHz"},{"name":"Range","range":"(0,8 – 240) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 80 MHz do 90 GHz"},{"name":"范围","range":"(0,8 – 240) V/m"}],"search_zh":"工作环境 － 使用无线电通信系统发射设备时作业空间内的电磁场（移动电话系统基站） 电场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 使用无线电通信系统发射设备时作业空间内的电磁场（移动电话系统基站）"},{"_id":"6a8324dc884ede9a1b2c4f95","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 27 MHz do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1,5) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 27 MHz do 1 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 27 MHz do 1 GHz\nZakres (0,01 – 1,5) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 27 MHz do 1 GHz"},{"name":"Range","range":"(0,01 – 1,5) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 27 MHz do 1 GHz"},{"name":"范围","range":"(0,01 – 1,5) A/m"}],"search_zh":"工作环境 － 使用无线电通信系统发射设备时作业空间内的电磁场（移动电话系统基站） 磁场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 使用无线电通信系统发射设备时作业空间内的电磁场（移动电话系统基站）"},{"_id":"6a8324dc884ede9a1b2c4f96","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 800 MHz do 90 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz do 90 GHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz do 90 GHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej, nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 800 MHz do 90 GHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 800 MHz do 90 GHz"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength: (calculated) in the frequency range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"(calculated)","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 800 MHz do 90 GHz"}],"search_zh":"工作环境 － 使用无线电通信系统发射设备时作业空间内的电磁场（移动电话系统基站） 磁场强度： （计算得出） 频率范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"（计算得出）","test_object_zh":"工作环境 － 使用无线电通信系统发射设备时作业空间内的电磁场（移动电话系统基站）"},{"_id":"6a8324dc884ede9a1b2c4f97","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 80 MHz do 90 GHz"},{"name":"Zakres","range":"(0,8 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,8 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 80 MHz do 90 GHz\nZakres (0,8 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 80 MHz do 90 GHz\nZakres (0,8 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 80 MHz do 90 GHz"},{"name":"Range","range":"(0,8 – 200) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 80 MHz do 90 GHz"},{"name":"范围","range":"(0,8 – 200) V/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a8324dc884ede9a1b2c4f98","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 80 MHz do 90 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 80 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 80 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 80 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 80 MHz do 90 GHz"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: (calculated) in the frequency range Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"(calculated)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 80 MHz do 90 GHz"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 磁场强度： （计算得出） 频率范围 Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"（计算得出）","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a8324dc884ede9a1b2c4f99","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 420 MHz do 6 GHz"},{"name":"Zakres","range":"(0,1 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 420 MHz do 6 GHz\nZakres (0,1 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 420 MHz do 6 GHz\nZakres (0,1 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 420 MHz do 6 GHz\nZakres (0,1 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 420 MHz do 6 GHz"},{"name":"Range","range":"(0,1 – 200) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength: Direct measurement method in the frequency range Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 420 MHz do 6 GHz"},{"name":"范围","range":"(0,1 – 200) V/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（选频测量） 电场强度： 直接测量法 频率范围 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（选频测量）"},{"_id":"6a8324dc884ede9a1b2c4f9a","lab_id":"69ad52a3de79e566650fb9af","country":"PL","accr_number":"AB 1810","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 420 MHz do 6 GHz"}],"technique":"(z obliczeń)","techniques":["(z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 420 MHz do 6 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"LABORATORIUM ul. Jeżycka 36/3, 60-865 Poznań","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 420 MHz do 6 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary selektywne) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 420 MHz do 6 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 420 MHz do 6 GHz"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength: (calculated) in the frequency range Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"(calculated)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 420 MHz do 6 GHz"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（选频测量） 磁场强度： （计算得出） 频率范围 Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"（计算得出）","test_object_zh":"环境 － 无线电通信设施周围的电磁场（选频测量）"}],"has_pdf":true}